Datasheet

DA30-P736
custom power relay
• power relay with PCB option
• Up to 30A rating (switched), 32A (carry)
• compact form factor
• high isolation with > 6mm contact gap
• RoHS Compliant
Contacts
Contact number & arrangement
SPST-NO (1 Form X)
Contact material
AgNi 90/10
Max. switching voltage
AC/DC 400VAC / 125VDC
Max. switching power
7500VA
Min. switching current / voltage
10mA/10VDC
Rated load
AC1 32A, 277VAC (carry); 30A, 250VAC (switched)
DC1 30A / 30VDC (switched)
Initial resistance
Max: 50mΩ, Typical: 5mΩ
Coil
Rated voltage
DC 12VDC
Operating range of supply voltage
See coil table 1
Rated power consumption
DC 1.3W
Insulation
Insulation resistance
≤ 1000MΩ at 500VDC, 50%RH
Dielectric strength
coil to contact >4000Vrms, 1min
coil to contact, creepage and clearance >8mm
between open contacts 2500Vrms, 1min; Contact gap: >6mm (2 x >3mm)
open contacts, creepage distance >8mm
General Data
Operating time (max)
mS ≤ 10ms (excluding bounce time)
Release time (max)
mS ≤ 12ms
Electrical Life
ops ≥ 1 x 105
Mechanical life
ops ≥ 1 x 107
Dimensions
L x W x H 42 x 35.5 x 35.5mm (see Fig 1)
Weight
73g
Ambient temperature
storage -40 to 105°C
operating -40 to 95°C
Shock resistance
20g / 11mS
Vibration resistance
DA 1.5mm 10-55Hz / 20g
Specifications are subject to change without notice. E&OE.
Page 1 of 2 www.durakoolrelays.com
Ref: DA30 - P736 071911JHM
Sales Department Tel: (888) 847-6552
DA30-P736
custom power relay
Coil Data (DC coil)
Table 1
Coil Voltage Code
Nominal Voltage
(VDC)
Coil Resistance (Ω)
±10%
Coil Current
mA
1012
12
90
133
Coil operating range (at 20°C) VDC
min.
max.
9.6
13.2
Operating relays below or above the nominal voltage may prove detrimental to overall performance.
Overall Dimensions
Fig. 1
Wiring Diagram (Bottom View)
Dimensions in mm
(Bottom View)
Ordering codes
Contact Material
Type
D
A
3
0
-
2
0
Contact
arrangement
2
1
Cover protection
and mounting
-
2
5
Contact material
20
-
SPST-NO (1N/O) (1 Form X)
Cover protection category and connection
25
-
in cover, IP40, PCB terminals
Special Options
P736
Improved isolation
Specifications are subject to change without notice. E&OE.
Page 2 of 2 www.durakoolrelays.com
Ref: DA30-P736 071911JHM
-
1
0
1
see Table 1
AgNi 90/10
Contact arrangement
21
Coil code
Sales Department Tel: (888) 847-6552
2
-
P736