KXSS5 Product Brief

KXSS5 Series
Accelerometers and Inclinometers
FEATURES
MARKETS
Very Small Package - 3x5x0.9mm LGA
I2C/SPI Interface and Analog Outputs
APPLICATIONS
Hard Disk Drives/Laptops
Free-fall Detection
Free-fall Interrupt Output
Cell Phones and Handheld PDAs
High-g Motion Interrupt Output
Gesture Recognition
Low Noise
Lead-free Solderability
Game Controllers and Computer Peripherals
Excellent Temperature Performance
High Shock Survivability
Inclination and Tilt Sensing
Cameras and Video Equipment
Low Power Consumption
Selectable Power Reduction Modes
User Definable Bandwidth
Factory Programmable Offset and Sensitivity
Image Stabilization
Sports Diagnostic Equipment/Pedometers
Static or Dynamic Acceleration
Personal Navigation Devices
Self-test Function
Inertial Navigation and Dead Reckoning
PROPRIETARY TECHNOLOGY
These high-performance silicon micromachined linear accelerometers and
inclinometers consist of a sensor element and an ASIC packaged in a
3x5x0.9mm Land Grid Array (LGA). The sensor element is fabricated from
single-crystal silicon with proprietary Deep Reactive Ion Etching (DRIE)
processes, and is protected from the environment by a hermetically-sealed
silicon cap at the wafer level.
The KXSS5 series is designed to provide a high signal-to-noise ratio with
excellent performance over temperature. These sensors can accept supply
voltages between 1.8V and 5.25V.
Sensitivity is factory programmable
allowing customization for applications requiring from ±2.5g to ±8.0g
ranges. Sensor bandwidth is user-definable. Interrupts can be generated
for acceleration on any axis above a threshold value (Motion Interrupt) or
for acceleration on all three axes below a threshold value (Free-fall Interrupt).
The sensor element functions on the principle of differential capacitance.
Acceleration causes displacement of a silicon structure resulting in a
change in capacitance. An ASIC, using a standard CMOS manufacturing
process, detects and transforms changes in capacitance into an analog output voltage, which is proportional to acceleration. This voltage is digitized
by an on-board A/D converter and is accessed via an inter-integrated circuit (I2C) bus or serial peripheral interface (SPI).
36 Thornwood Dr. - Ithaca, NY 14850 USA tel: 607-257-1080 - fax: 607-257-1146 - www.kionix.com - [email protected]
“Kionix” is a registered trademark of Kionix, Inc. Products described herein are protected by patents issued or pending. Information provided
in this document is believed to be accurate and reliable but is not guaranteed. Kionix does not assume responsibility for its use or distribution.
No license is granted by implication or otherwise under any patent or other rights of Kionix. Kionix reserves the right to change product
specifications or discontinue this product at any time without prior notice.
© Kionix 2010 All Rights Reserved
July 27, 2010 Rev. 1.1
Page 1 of 2
KXSS5 Series
Accelerometers and Inclinometers
PERFORMANCE SPECIFICATIONS
The performance parameters below are programmed and tested at 3.3 volts. However, the device can be factory
programmed to accept supply voltages from 1.8 V to 5.25 V. Performance parameters will change with supply
voltage variations.
PERFORMANCE SPECIFICATIONS
PARAMETERS
UNITS
KXSS5-2057
CONDITION
g
±3.0
Factory programmable
counts/g
546 typical (562 max)
12 bit operation
0g Offset vs. Temp.
mg/°C
±0.6 typical
Sensitivity vs. Temp
%/°C
0.01 (xy)
0.03 (z)
g / Hz
175 (typical)
Hz
1000
-3dB
% of FS
0.1 typical
% of full scale output
Ratiometric Error
%
0.3 typical
3.3V ± 5%
Cross-axis Sensitivity
%
2.0 typical
A/D Conversion Time
µS
200 typical
MHz
1 typical
KHz
400 typical
V
3.3
Standard
µA
800 typical (1000 max)
Operating
µA
0.0012 typical
Standby
Range
1
Sensitivity
Noise
Bandwidth
2
Non-Linearity
SPI Communication Rate
3
2
I C Communication Rate
Power Supply
Current Consumption
ENVIRONMENTAL SPECIFICATIONS
PARAMETERS
UNITS
KXSS5-2057
CONDITION
Operating Temperature
°C
-40 to 85
Powered
Storage Temperature
°C
-55 to 150
Un-powered
Mechanical Shock
g
5000
Powered or un-powered,
0.5 msec halversine
ESD
V
2000
Human body model
NOTES
1
Custom ranges from 2.5g to 8g available.
2
Internal 1 kHz low pass filter. Lower frequencies are user definable with external capacitors.
3
SPI communication rate can be optimized for faster communication.
ORDERING GUIDE
Axis(es) of
Sensitivity
Range
(g)
Sensitivity
(counts/g)
Offset
(counts)
Operating Voltage
(V)
Output
Temperature
(°C)
Package
KXSS5-2057
XYZ
3
546
2048
3.3
Digital I2C, SPI,
Analog
-40 to +85
3x5x0.9 LGA
KXSS5-3028
XYZ
3
546
2048
2.8
Digital I2C, SPI,
Analog
-40 to +85
3x5x0.9 LGA
-25 to +70
3x5x0.9 LGA
Product
KXSS5-4457
XYZ
3
546
2048
1.8
2
Digital I C, SPI,
Analog
© Kionix 2010 All Rights Reserved
July 27, 2010 Rev. 1.1
Page 2 of 2