65280A

65280A
One-Year Limited Warranty
Measurement Specialties, Inc. warrants this product against defects
in materials and workmanship for a period of one year from date
of shipment. During the warranty period, Measurement Specialties
will, at its option, either repair or replace products which prove to
be defective.
Battery Charger
Exclusions
This warranty does not apply to defects or damage resulting from:
•Improper installation or maintenance
•Customer supplied software or interfacing
•Unauthorized modification or misuse
•Operation outside of the product specifications
Limitations
The warranty set forth above is exclusive and no other warranty,
whether written or oral, is expressed or implied. Measurement
Specialties specifically disclaims the implied warranties of
merchantability and fitness for a particular purpose.
Some jurisdictions do not allow limitations on how long an implied
warranty lasts, so the above limitation or exclusion may not apply to
you. However, any implied warranty of merchantability or fitness is
limited to the one-year duration of this written warranty.
Measurement Specialties, Inc.
2236 N. Cleveland-Massillon Rd.
Akron, Ohio 44333-1255 USA
(330) 659-3312 www.meas-spec.com
precisionsensors.meas-spec.com
Warranty Service
To obtain service during the warranty period, products must be
returned, transportation prepaid, to Measurement Specialties.
65280A Rev. 7/24/13
How to Use the 65280A
Connections
or
Male D-Shell
Connector
Pin
5
7
Barrel
Connector
Description
Ground
Vout
Pin
Outside
Inside
Description
Ground
Vout
Status Light
Status
Off
Flashing Red
Flashing Green
Steady Green
Flashing Red/Green
Definition
No power or No battery connected
AC power applied in last 1/2 second
Fast charging
Fully charged, topping off
Battery terminals shorted
►Plug
►
wall adapter into a 110 VAC outlet and attach its
cable to the charger. The status light on the charger will
flash red for 1/2 second.
►Connect
►
the charger to a compatible Measurement
Specialties device or battery pack. The status light on
the charger will begin flashing green, indicating that the
battery is charging.
►The
►
status light will stop flashing and remain steady green
when the battery is fully charged.
►After
►
being fully charged, a battery can be topped off by
leaving the charger attached for an additional hour after
the status light stops flashing. The battery charger will
automatically stop charging after the battery is topped off.
Every 24 hours the battery charger will check the battery
and top off if required. The status light remains steady
green during this process.
►Battery
►
should be stored at approximately 40% charge
level (14.5 V to 15.5 V). Click ‘Battery Monitor’ in ICU
to check status. Unit may be discharged by turning on, but
use of an RF terminator (dummy load) to stop radiation is
recommended.
►Immediately
►
disconnect power whenever the status
light flashes Red/Green as this indicates that the battery
terminals are shorted.
Specifications*
Output current
Output voltage
Input voltage
Min Typical Max Units
0.84
A
16.8 VDC
110
VAC
*Data subject to change without notice