BE134

Time and hours meters electronic
2 presets, PNP, NPN logic
Display LCD, 6-digits, programmable
BE134
Features
–– Hour counter with 2 presets
–– Display 6-digits
–– Totalizer for hour
–– Counting range 9999.99 s / 999.95.9 min / 9999.59 min
/ 9999.59 h
–– With reset
–– Connection: Count impulse, NPN, PNP logic
–– Batch counter with preset
BE134 - two presets
Technical data - electrical ratings
Technical data - electrical ratings
Voltage supply
24/48 VAC ±10 % (50/60 Hz)
85...265 VAC (50/60 Hz)
12...30 VDC
Approval
Power consumption
5 VA, 5 W
Sensor supply
24/48 VAC: 10-26 VDC/60 mA
85...265 VAC:
24 VDC ±20 %/100 mA
12...30 VDC: 9-28 VDC/100 mA
Number of digits
6-digits
Totalizer in 2 steps (8-digits)
Ambient temperature
0...+45 °C
Storage temperature
-20...+70 °C
Relative humidity
80 % non-condensing
Connection
Plug-in screw terminal
connector
Core cross-section
1.5 mm²
Protection DIN EN 60529
IP 65 (face with seal)
Membrane with softkeys
Digit height
7 mm (postion value)
4 mm (preset)
Operation / keypad
Housing type
Built-in housing
Function
Hour counter
Main counter with 2 presets
Dimensions W x H x L
48 x 48 x 100 mm
Count mode
Adding or subtracting
Mounting depth
100 mm
Counting frequency
Batch counter: approx. 20 Hz
Mounting
Clip frame for built-in housing
Presets
1 preset, 2 presets
Cutout dimensions
45 x 45 mm (+0.6)
Operating mode
Time meter and hour counter
Weight approx.
150 g (12-30 VDC/85-265 VAC),
250 g (24/48 VAC)
Data memory
>10 years in EEPROM
Materials
Reset
Button, electric or automatic
Housing: Makrolon 6485 (PC)
Keypad: Polyester
Keylock
Yes, electric (keylock)
Outputs electronic
Optocoupler
Outputs relay
Normally open or closed,
programmable
Output holding time
0.01...99.99 s
Interface
RS485
Standard
DIN EN 61010‑1
Protection class II
Overvoltage category II
Pollution degree 2
Emitted interference
DIN EN 61000-6-4
Interference immunity
DIN EN 61000-6-2
Programmable
parameters
Measuring units, sensor logic
Control inputs
1
www.baumer.com/motion
Subject to modification in technic and design. Errors and omissions excepted.
LCD, 7-segment display,
2-lines, backlit
Technical data - mechanical design
14/5/2014
Display
UL approval / E63076
Time and hours meters electronic
2 presets, PNP, NPN logic
Display LCD, 6-digits, programmable
BE134
Part number
Block circuit diagram
AX01
Voltage
supply
Voltage supply
1 24 / 48 VAC
2 85...265 VAC
3 12...30 VDC
Z 118.034
Adaptor plate for clip mount,
face 53.2 x 53.2 mm
Z 118.035
Adaptor plate for clip mount,
face 60 x 75 mm
Connection diagram
3
3
2XWSXWV
PD[9
WHUPLQDOWHUPLQDO
&RQWURO
LQSXW
%
$
± 6HQVRU
56 VXSSO\
75
75
$
6LJQDO
LQSXW
3
3
2XWSXWV
PD[9
WHUPLQDOWHUPLQDO
WHUPLQDO
8
13
Main counter with
presets
3
Output
9
2
10
3
11
-
4
P1
5
6
P2
Batch counter with
or without preset
Interface
RS485
Comparator inputs
Input circuit
Inputs
PNP- / NPN-logic
Input level
Programmable
Input level Low
0...2 VDC
Input level High
3...40 VDC
Input resistance
3 kΩ
Relay outputs
Output circuit
Switching voltage max.
250 VAC / 110 VDC
Switching current max.
1A
Switching capacity max.
150 VA / 30 W
Relay responding time
5 ms
Electronical outputs
Output circuit
Optocoupler short-circuit proof
Switching voltage max.
40 V
Switching current max.
25 mA
9ROWDJHVXSSO\
6LJQDO
LQSXW
9ROWDJHVXSSO\
± 6HQVRU &RQWURO
LQSXW
56 VXSSO\
%
75
75
(OHFWURQLFRXWSXWV
7
B (Stop)
Totalizer
Sensor
supply
+
Subject to modification in technic and design. Errors and omissions excepted.
Adaptor plate for screw mount,
face 60 x 75 mm
A (Start)
12
Trigger level
Adaptor plates
2
T,R+ 15
Accessories
+
T,R- 14
Interface
0 Without interface
1 RS485
5HOD\RXWSXWV
1
Control input
1
Outputs
1 Relay outputs
2 Optocoupler outputs
Z 118.033
-
WHUPLQDO
Dimensions
2
www.baumer.com/motion
14/5/2014
BE134.