Time and hours meters electronic 2 presets, PNP, NPN logic Display LCD, 6-digits, programmable BE134 Features –– Hour counter with 2 presets –– Display 6-digits –– Totalizer for hour –– Counting range 9999.99 s / 999.95.9 min / 9999.59 min / 9999.59 h –– With reset –– Connection: Count impulse, NPN, PNP logic –– Batch counter with preset BE134 - two presets Technical data - electrical ratings Technical data - electrical ratings Voltage supply 24/48 VAC ±10 % (50/60 Hz) 85...265 VAC (50/60 Hz) 12...30 VDC Approval Power consumption 5 VA, 5 W Sensor supply 24/48 VAC: 10-26 VDC/60 mA 85...265 VAC: 24 VDC ±20 %/100 mA 12...30 VDC: 9-28 VDC/100 mA Number of digits 6-digits Totalizer in 2 steps (8-digits) Ambient temperature 0...+45 °C Storage temperature -20...+70 °C Relative humidity 80 % non-condensing Connection Plug-in screw terminal connector Core cross-section 1.5 mm² Protection DIN EN 60529 IP 65 (face with seal) Membrane with softkeys Digit height 7 mm (postion value) 4 mm (preset) Operation / keypad Housing type Built-in housing Function Hour counter Main counter with 2 presets Dimensions W x H x L 48 x 48 x 100 mm Count mode Adding or subtracting Mounting depth 100 mm Counting frequency Batch counter: approx. 20 Hz Mounting Clip frame for built-in housing Presets 1 preset, 2 presets Cutout dimensions 45 x 45 mm (+0.6) Operating mode Time meter and hour counter Weight approx. 150 g (12-30 VDC/85-265 VAC), 250 g (24/48 VAC) Data memory >10 years in EEPROM Materials Reset Button, electric or automatic Housing: Makrolon 6485 (PC) Keypad: Polyester Keylock Yes, electric (keylock) Outputs electronic Optocoupler Outputs relay Normally open or closed, programmable Output holding time 0.01...99.99 s Interface RS485 Standard DIN EN 61010‑1 Protection class II Overvoltage category II Pollution degree 2 Emitted interference DIN EN 61000-6-4 Interference immunity DIN EN 61000-6-2 Programmable parameters Measuring units, sensor logic Control inputs 1 www.baumer.com/motion Subject to modification in technic and design. Errors and omissions excepted. LCD, 7-segment display, 2-lines, backlit Technical data - mechanical design 14/5/2014 Display UL approval / E63076 Time and hours meters electronic 2 presets, PNP, NPN logic Display LCD, 6-digits, programmable BE134 Part number Block circuit diagram AX01 Voltage supply Voltage supply 1 24 / 48 VAC 2 85...265 VAC 3 12...30 VDC Z 118.034 Adaptor plate for clip mount, face 53.2 x 53.2 mm Z 118.035 Adaptor plate for clip mount, face 60 x 75 mm Connection diagram 3 3 2XWSXWV PD[9 WHUPLQDOWHUPLQDO &RQWURO LQSXW % $ ± 6HQVRU 56 VXSSO\ 75 75 $ 6LJQDO LQSXW 3 3 2XWSXWV PD[9 WHUPLQDOWHUPLQDO WHUPLQDO 8 13 Main counter with presets 3 Output 9 2 10 3 11 - 4 P1 5 6 P2 Batch counter with or without preset Interface RS485 Comparator inputs Input circuit Inputs PNP- / NPN-logic Input level Programmable Input level Low 0...2 VDC Input level High 3...40 VDC Input resistance 3 kΩ Relay outputs Output circuit Switching voltage max. 250 VAC / 110 VDC Switching current max. 1A Switching capacity max. 150 VA / 30 W Relay responding time 5 ms Electronical outputs Output circuit Optocoupler short-circuit proof Switching voltage max. 40 V Switching current max. 25 mA 9ROWDJHVXSSO\ 6LJQDO LQSXW 9ROWDJHVXSSO\ ± 6HQVRU &RQWURO LQSXW 56 VXSSO\ % 75 75 (OHFWURQLFRXWSXWV 7 B (Stop) Totalizer Sensor supply + Subject to modification in technic and design. Errors and omissions excepted. Adaptor plate for screw mount, face 60 x 75 mm A (Start) 12 Trigger level Adaptor plates 2 T,R+ 15 Accessories + T,R- 14 Interface 0 Without interface 1 RS485 5HOD\RXWSXWV 1 Control input 1 Outputs 1 Relay outputs 2 Optocoupler outputs Z 118.033 - WHUPLQDO Dimensions 2 www.baumer.com/motion 14/5/2014 BE134.