VISTA-128BPT SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS The VISTA-128BPT is a powerful member of the Honeywell The VISTA-128BPT and VISTA-128BPTSIA are listed for family of commercial alarm panels, integrating burglary, CCTV residential burglary, residential fire and commercial burglary and access control functions. Many features are available that applications (see agency listings in this document for extend the applications of the VISTA-128BPT while simplifying more details). They are compatible with a wide range of end-user operation. AlarmNet communications products for alarm reporting, uploading /downloading and remote services. FEATURES Standard features (VISTA-128BPT and VISTA-128BPTSIA): • Provides nine style-B hardwired zones • Supports up to 119 additional zones using a built-in polling (V-Plex®, multiplex) loop interface • Supports up to 127 wireless zones using up to two 5800 series wireless receivers (fewer if using hardwire and/or polling loop zones) • Provides one power-limited bell circuit delivering 1.7Amp (max) at 12VDC • Provides the ability to control eight separate partitions independently, each functioning as if it had its own separate control • Accommodates 150 user codes with seven authority levels • Accommodates 32 keypad macro commands per system • Keeps a log of up to 512 events • Supports up to 16 compatible two-wire smoke detectors on zone 1 • Zone 7 may be used for keyswitch arming/disarming • Group bypass • Integrates with WIN-PAK access control systems to provide increased users, event log and scheduling • Event arming • Supports V-Plex addressable VistaKey access control (up to eight doors and 250 cards) • Easily programmed and maintained by Compass Windows-based downloader • Supports up to 96 programmable outputs • Programmable to meet SIA false alarm prevention specifications. To meet UL approval for ANSI/SIA CP-01-2010, order part number V128BPTSIA • Arm faulted • Carbon monoxide (CO) zone type support • Expanded high-speed RS-232 capability for third party interface and automation • Internet upload/download over AlarmNet GSM and/or IP communicators over the panel's keypad (ECP) bus • Ringback support for AlarmNet communicators (confirmation of closing report) • 24-hour dialer test support for AlarmNet devices • Supports up to six touchscreen Advanced User Interface (AUI) devices (6272 or later) • Supports V-Plex Smart Contact feature for improved responsiveness on systems with many V-Plex zones • Smoke detector reset at keypad • Telco line cut detection • Quick exit VISTA-128BPT SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS ADDITIONAL FEATURES Basic Hardwired Zones Wireless Expansion Eight Partitions Provides nine style-B hardwired zones with the following characteristics: Supports up to 127 wireless zones using up to two 5800 Series wireless receivers (fewer if using hardwire and/or polling loop zones). Provides the ability to control eight separate areas independently, each functioning as if it had its own separate control. Partitioning features include: Wireless zones have the following characteristics: • A Common Lobby partition (1-8), which can be programmed to arm automatically when the last partition that shares the common lobby is armed, and to disarm when the first partition that shares the common lobby is disarmed • EOLR supervision (optional for zones 2-8) supporting N.O. or N.C. sensors (EOLR supervision required for fire and UL burglary installations) • Individually assignable to one of eight partitions • Up to 16 two-wire smoke detectors on zone 1 • Four-wire smoke or heat detectors on zones 1-8 (power to four-wire smoke detectors must be supervised with an EOL device). Listed for residential fire only. Polling Loop Expansion Supports up to 119 additional zones using a built-in polling (V-Plex, multiplex) loop interface. Current draw can total up to 128mA. Polling loop zones have the following characteristics: • Must use V-Plex devices • Supervised by control panel • Individually assignable to one of eight partitions • Supports VSI Module • Supports 4297 Expander Module • Maximum wiring distance = 12,000 feet • Supervised by control panel for check-in signals (except certain non-supervised transmitters) • Tamper protection for supervised transmitters Scheduling • A Master partition (9), used strictly to assign keypads for the purpose of viewing the status of all eight partitions at the same time (master keypads) Provides the following scheduling capabilities: • All zones assignable to one of eight partitions • Open/close schedules (for control of arming/disarming and reporting) • Keypads assignable to one of eight partitions or to Master partition 9 to view system status • Individually assignable to one of eight partitions • Holiday schedules (allows different time windows for open/close schedules) • Ability to assign relays to one or all eight partitions • Timed events (for activation of relays, auto-bypassing and unbypassing, auto-arming and disarming, etc.) • Ability to display fire and/or burglary and panic and/or trouble conditions at all other partitions’ keypads (selectable option) • Access schedules (for limiting system access to users by time) • Individually programmable account number, entry delay and exit delay by partition • End user output programming mode (provides 20 timers for output control) V-Plex Loop 4101SN Relay Module DT7500SN V-Plex DUAL TEC Motion Sensor FG1625SN Glassbreak 4208EX Eight-zone V-Plex Expander and 4208SN Serialized Eight-zone Remote Point Module 5193 Series Smoke Detectors 4293SN Adapters 5881 Wireless Receiver ECP Bus 6160 Console 710 Strobe Light VISTA-128BPT Notification Appliances Serial Printer PC Connection 4204 Relay Module Keyswitch Option 4146 Phone Line to Central Station 748 Horn RS-232 or 7847i NOTE: Please refer to the website (www.honeywell.com/security/hsc) for the latest product information. or GSMV iGSMV VISTA-128BPT SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS ACCESSORIES Auxiliary Devices Passive Infrared Detectors • 5819 - Shock Sensor • 4204 - Relay Module, four form C contacts • IS2500SN • 5827BD - Bidirectional Keypad • DT7500SN • 5853 - Glassbreak Detector V-Plex (Addressable) Contacts • 5898 - Wireless DUAL TEC Motion Sensor • 5881 Series - RF Receiver supporting 5800 wireless detectors • 6160 - Alpha Keypad/Annunciator • 4939SN-WH • 5800PIR-OD - Outdoor Motion Sensor • 4944SN-WH • 6220S - System Printer • 5870API - Asset Protection Device • 4959SN Manual Pull Stations V-Plex Glassbreak Detectors • 5140MPS-1 • FG1625SN • 5140MPS-2 V-Plex (addressable) Devices • 4101SN Single Relay/Zone Module • 4190SN Remote Point Module two zones • 4193SN Two-zone Serial Interface Module • 4208EX - Eight-zone expander for ULC commercial installations • 4208SN Loop Expansion Module eight zones • 4209U Group Zoning Module two/four zones VISTA Interactive Phone Module • 5800CO (5800COA - Canada) Wireless Carbon Monoxide Detector • 4286 VIP Module • 5800RP - Wireless Repeater Optional Communicators • 5808W3 (5808W3A - Canada) Wireless Smoke Detector • AlarmNet Internet/Intranet communicators and digital cellular communicators Access Control • VISTAKey V-Plex (addressable) Access Control • VISTAKey-SK Starter Kit Wireless Devices • 5193SD • 5817CB - Commercial UL Burglary, Universal Contact Monitoring Transmitter* *When used with 5881ENHC and/or 5883H receiver. • 5804BD - Bidirectional Key • VSI Short/Overload Isolation Module Commercial Listed Wireless Devices • 5881ENHC and 5883H Receivers • 5804 - Wireless Key • 4297 Isolation/Extender Module • 5809 - Wireless Heat Detector • 5869 - Commercial UL Wireless Hold-up Button* • VISTAKey-EX Expansion Kit • 4293SN One-zone Serial Interface Module • 5800PIR/5800PIR-RES/5800PIR-COM - Wireless Motion Detectors • 5804BDV - Bidirectional Key with voice • 5816 - Door/Window Transmitter • 5193SDT IS2500SN V-Plex PIR Motion Sensor ECP 4193SN 4208U Two-zone Serial Interface Module Eight-zone Expansion Module 5881ENHC Commercial Wireless Receiver Bus (Max Two) 6160 Console 4190SN Remote Point Module 5808W3 (5808W3A - Canada) Wireless Smoke Detector 5816 Door/Window Transmitter 4204 Relay Module 5869 Commercial UL Wireless Hold-up Button 4959SN Overhead Door Contact 4944SN Contact VISTAKey V-Plex Access Control Module Glassbreak Detectors 5800 Series Wireless Devices 5800PIR Series Wireless PIRs 4209U Group Zoning Module 5817CB Universal Contact Monitoring Transmitter Supports Up To 16 Conventional Two-Wire Smoke Detectors VISTA-128BPT SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS SPECIFICATIONS Agency Listed to the Following Standards: Electrical • UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault • Voltage Input: From Honeywell No. 1361 Plug-In Transformer or 1361X10 transformer (for X-10 installations) rated 16.5VAC, 40 VA • UL1610 Grades A, AA Central Station • Use 1361CN plug-in transformer for Canada • UL365 Grades A, AA Police Connect • Alarm Sounder Output: 10VDC-13.8VDC, 1.7 amps max., (UL1023, UL609 installations); 750mA less aux. current draw (UL985 installations) • UL985 Household Fire • UL1023 Household Burglar Alarm California State Fire Marshall (CSFM) • UL1635 - Digital Alarm Communicator System Units • CAN/ULC - S303 • CAN/ULC - S304 • CAN/ULC - S545 • CAN/ULC - S1023 • For commercial burglary attack proof requirements, use N5873V4BE attack proof enclosure provided in VISTA-ULKT kit • Auxiliary Power Output: 9.6VDC13.8VDC, 750mA max. For UL installations, the accessories connected to the output must be UL Listed, and rated to operate in the above voltage range • Backup Battery: 12VDC, 4AH or 7AH sealed-lead acid. YUASA NP4-12 (12V, 4AH) or NP7-12 (12V, 7AH) recommended • Standby Time: Four hours min. with 750mA aux. load using 7AH battery • Circuit Protectors: PTC circuit breakers are used on battery input to protect against reverse battery connections and on alarm sounder output to protect against wiring faults (shorts). A solid state circuit breaker is used on auxiliary power output to protect against wiring faults (shorts). Main Dialer • Formats Supported: ADEMCO Contact ID with support for four-digit and ten-digit accounts and ADEMCO 4 + 2 Express • Line Seize: Double Pole • Ringer Equivalence: 0.7B Cabinet Dimensions 12-1/2" W X 14 1/2" H X 3" D ORDERING VISTA-128BPT Commercial Burglary Alarm Control Panel (UL Listed) V128BPTSIA SIA Approved Enhanced Commercial Burglary Alarm Control Panel (UL Listed) V128BPTCNKT VISTA-128BPT Commercial Burglary Alarm Control Panel with 1361CN Transformer (Canada only) For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 1.800.467.5875 www.honeywell.com L/VSTA128BPTD/D April 2011 © 2011 Honeywell International Inc.