VISTA-128BPT Series Data Sheet

VISTA-128BPT SERIES
PARTITIONED COMMERCIAL BURGLARY
ALARM CONTROL PANELS
The VISTA-128BPT is a powerful member of the Honeywell
The VISTA-128BPT and VISTA-128BPTSIA are listed for
family of commercial alarm panels, integrating burglary, CCTV
residential burglary, residential fire and commercial burglary
and access control functions. Many features are available that
applications (see agency listings in this document for
extend the applications of the VISTA-128BPT while simplifying
more details). They are compatible with a wide range of
end-user operation.
AlarmNet communications products for alarm reporting,
uploading /downloading and remote services.
FEATURES
Standard features
(VISTA-128BPT and VISTA-128BPTSIA):
• Provides nine style-B hardwired zones
• Supports up to 119 additional zones
using a built-in polling (V-Plex®,
multiplex) loop interface
• Supports up to 127 wireless zones
using up to two 5800 series wireless
receivers (fewer if using hardwire
and/or polling loop zones)
• Provides one power-limited bell circuit
delivering 1.7Amp (max) at 12VDC
• Provides the ability to control eight
separate partitions independently,
each functioning as if it had its own
separate control
• Accommodates 150 user codes with
seven authority levels
• Accommodates 32 keypad macro
commands per system
• Keeps a log of up to 512 events
• Supports up to 16 compatible
two-wire smoke detectors on zone 1
• Zone 7 may be used for keyswitch
arming/disarming
• Group bypass
• Integrates with WIN-PAK access
control systems to provide increased
users, event log and scheduling
• Event arming
• Supports V-Plex addressable
VistaKey access control (up to eight
doors and 250 cards)
• Easily programmed and maintained
by Compass Windows-based
downloader
• Supports up to 96 programmable
outputs
• Programmable to meet SIA false
alarm prevention specifications.
To meet UL approval for ANSI/SIA
CP-01-2010, order part number
V128BPTSIA
• Arm faulted
• Carbon monoxide (CO) zone
type support
• Expanded high-speed RS-232
capability for third party interface
and automation
• Internet upload/download
over AlarmNet GSM and/or
IP communicators over the panel's
keypad (ECP) bus
• Ringback support for AlarmNet
communicators (confirmation of
closing report)
• 24-hour dialer test support for
AlarmNet devices
• Supports up to six touchscreen
Advanced User Interface (AUI)
devices (6272 or later)
• Supports V-Plex Smart Contact
feature for improved responsiveness
on systems with many V-Plex zones
• Smoke detector reset at keypad
• Telco line cut detection
• Quick exit
VISTA-128BPT SERIES
PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS
ADDITIONAL FEATURES
Basic Hardwired Zones
Wireless Expansion
Eight Partitions
Provides nine style-B hardwired zones
with the following characteristics:
Supports up to 127 wireless zones
using up to two 5800 Series wireless
receivers (fewer if using hardwire
and/or polling loop zones).
Provides the ability to control eight
separate areas independently, each
functioning as if it had its own separate
control. Partitioning features include:
Wireless zones have the following
characteristics:
• A Common Lobby partition (1-8),
which can be programmed to arm
automatically when the last partition
that shares the common lobby is
armed, and to disarm when the first
partition that shares the common
lobby is disarmed
• EOLR supervision (optional for zones
2-8) supporting N.O. or N.C. sensors
(EOLR supervision required for fire
and UL burglary installations)
• Individually assignable to one of
eight partitions
• Up to 16 two-wire smoke detectors
on zone 1
• Four-wire smoke or heat detectors
on zones 1-8 (power to four-wire
smoke detectors must be supervised
with an EOL device). Listed for
residential fire only.
Polling Loop Expansion
Supports up to 119 additional zones
using a built-in polling (V-Plex, multiplex)
loop interface. Current draw can total
up to 128mA. Polling loop zones have
the following characteristics:
• Must use V-Plex devices
• Supervised by control panel
• Individually assignable to one of
eight partitions
• Supports VSI Module
• Supports 4297 Expander Module
• Maximum wiring distance =
12,000 feet
• Supervised by control panel for
check-in signals (except certain
non-supervised transmitters)
• Tamper protection for supervised
transmitters
Scheduling
• A Master partition (9), used strictly to
assign keypads for the purpose of
viewing the status of all eight partitions
at the same time (master keypads)
Provides the following scheduling
capabilities:
• All zones assignable to one of
eight partitions
• Open/close schedules (for control of
arming/disarming and reporting)
• Keypads assignable to one of eight
partitions or to Master partition 9 to
view system status
• Individually assignable to one of
eight partitions
• Holiday schedules (allows different
time windows for open/close
schedules)
• Ability to assign relays to one or all
eight partitions
• Timed events (for activation of relays,
auto-bypassing and unbypassing,
auto-arming and disarming, etc.)
• Ability to display fire and/or burglary
and panic and/or trouble conditions
at all other partitions’ keypads
(selectable option)
• Access schedules (for limiting system
access to users by time)
• Individually programmable account
number, entry delay and exit delay
by partition
• End user output programming mode
(provides 20 timers for output control)
V-Plex Loop
4101SN
Relay Module
DT7500SN
V-Plex DUAL TEC
Motion Sensor
FG1625SN Glassbreak
4208EX Eight-zone
V-Plex Expander and
4208SN Serialized Eight-zone
Remote Point Module
5193
Series Smoke Detectors
4293SN Adapters
5881
Wireless
Receiver
ECP Bus
6160
Console
710
Strobe
Light
VISTA-128BPT
Notification
Appliances
Serial Printer
PC Connection
4204
Relay
Module
Keyswitch
Option
4146
Phone Line to Central Station
748
Horn
RS-232
or
7847i
NOTE: Please refer to the website (www.honeywell.com/security/hsc) for the latest product information.
or
GSMV
iGSMV
VISTA-128BPT SERIES
PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS
ACCESSORIES
Auxiliary Devices
Passive Infrared Detectors
• 5819 - Shock Sensor
• 4204 - Relay Module, four form
C contacts
• IS2500SN
• 5827BD - Bidirectional Keypad
• DT7500SN
• 5853 - Glassbreak Detector
V-Plex (Addressable) Contacts
• 5898 - Wireless DUAL TEC
Motion Sensor
• 5881 Series - RF Receiver supporting
5800 wireless detectors
• 6160 - Alpha Keypad/Annunciator
• 4939SN-WH
• 5800PIR-OD - Outdoor Motion Sensor
• 4944SN-WH
• 6220S - System Printer
• 5870API - Asset Protection Device
• 4959SN
Manual Pull Stations
V-Plex Glassbreak Detectors
• 5140MPS-1
• FG1625SN
• 5140MPS-2
V-Plex (addressable) Devices
• 4101SN Single Relay/Zone Module
• 4190SN Remote Point Module two zones
• 4193SN Two-zone Serial Interface
Module
• 4208EX - Eight-zone expander for
ULC commercial installations
• 4208SN Loop Expansion Module eight zones
• 4209U Group Zoning Module two/four zones
VISTA Interactive Phone Module
• 5800CO (5800COA - Canada) Wireless Carbon Monoxide Detector
• 4286 VIP Module
• 5800RP - Wireless Repeater
Optional Communicators
• 5808W3 (5808W3A - Canada) Wireless Smoke Detector
• AlarmNet Internet/Intranet
communicators and digital cellular
communicators
Access Control
• VISTAKey V-Plex (addressable)
Access Control
• VISTAKey-SK Starter Kit
Wireless Devices
• 5193SD
• 5817CB - Commercial UL Burglary,
Universal Contact Monitoring
Transmitter*
*When used with 5881ENHC and/or
5883H receiver.
• 5804BD - Bidirectional Key
• VSI Short/Overload Isolation Module
Commercial Listed
Wireless Devices
• 5881ENHC and 5883H Receivers
• 5804 - Wireless Key
• 4297 Isolation/Extender Module
• 5809 - Wireless Heat Detector
• 5869 - Commercial UL Wireless
Hold-up Button*
• VISTAKey-EX Expansion Kit
• 4293SN One-zone Serial
Interface Module
• 5800PIR/5800PIR-RES/5800PIR-COM
- Wireless Motion Detectors
• 5804BDV - Bidirectional Key
with voice
• 5816 - Door/Window Transmitter
• 5193SDT
IS2500SN
V-Plex PIR
Motion Sensor
ECP
4193SN
4208U
Two-zone Serial Interface Module
Eight-zone
Expansion Module
5881ENHC
Commercial Wireless Receiver
Bus
(Max Two)
6160
Console
4190SN
Remote Point Module
5808W3
(5808W3A - Canada)
Wireless
Smoke Detector
5816
Door/Window
Transmitter
4204
Relay
Module
5869
Commercial UL
Wireless Hold-up
Button
4959SN
Overhead Door Contact
4944SN
Contact
VISTAKey V-Plex
Access Control
Module
Glassbreak Detectors
5800
Series
Wireless
Devices
5800PIR Series
Wireless PIRs
4209U
Group Zoning
Module
5817CB Universal
Contact Monitoring
Transmitter
Supports Up To
16 Conventional
Two-Wire
Smoke Detectors
VISTA-128BPT SERIES
PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS
SPECIFICATIONS
Agency Listed to the
Following Standards:
Electrical
• UL609 Grade A Local Mercantile
Premises and Mercantile Safe
and Vault
• Voltage Input: From Honeywell No.
1361 Plug-In Transformer or
1361X10 transformer (for X-10
installations) rated 16.5VAC, 40 VA
• UL1610 Grades A, AA
Central Station
• Use 1361CN plug-in transformer
for Canada
• UL365 Grades A, AA Police Connect
• Alarm Sounder Output:
10VDC-13.8VDC, 1.7 amps max.,
(UL1023, UL609 installations);
750mA less aux. current draw
(UL985 installations)
• UL985 Household Fire
• UL1023 Household Burglar Alarm
California State Fire Marshall (CSFM)
• UL1635 - Digital Alarm
Communicator System Units
• CAN/ULC - S303
• CAN/ULC - S304
• CAN/ULC - S545
• CAN/ULC - S1023
• For commercial burglary attack
proof requirements, use N5873V4BE
attack proof enclosure provided in
VISTA-ULKT kit
• Auxiliary Power Output: 9.6VDC13.8VDC, 750mA max. For UL
installations, the accessories
connected to the output must be UL
Listed, and rated to operate in the
above voltage range
• Backup Battery: 12VDC, 4AH or 7AH
sealed-lead acid. YUASA NP4-12
(12V, 4AH) or NP7-12 (12V, 7AH)
recommended
• Standby Time: Four hours min. with
750mA aux. load using 7AH battery
• Circuit Protectors: PTC circuit
breakers are used on battery input to
protect against reverse battery
connections and on alarm sounder
output to protect against wiring faults
(shorts). A solid state circuit breaker
is used on auxiliary power output to
protect against wiring faults (shorts).
Main Dialer
• Formats Supported: ADEMCO
Contact ID with support for four-digit
and ten-digit accounts and
ADEMCO 4 + 2 Express
• Line Seize: Double Pole
• Ringer Equivalence: 0.7B
Cabinet Dimensions
12-1/2" W X 14 1/2" H X 3" D
ORDERING
VISTA-128BPT
Commercial Burglary Alarm Control Panel (UL Listed)
V128BPTSIA
SIA Approved Enhanced Commercial Burglary Alarm Control Panel (UL Listed)
V128BPTCNKT
VISTA-128BPT Commercial Burglary Alarm Control Panel with 1361CN Transformer (Canada only)
For more information:
www.honeywell.com/security/hsc
Automation and Control Solutions
Honeywell Security & Communications
2 Corporate Center Dr. Suite 100
P.O. Box 9040
Melville, NY 11747
1.800.467.5875
www.honeywell.com
L/VSTA128BPTD/D
April 2011
© 2011 Honeywell International Inc.