TClamp1202P Datasheet

TClamp1202P
Low Capacitance TClamp®
Surge Protection for 12V Interfaces
PROTECTION PRODUCTS - TransClamp®
Description
PRELIMINARY
Features
TClamp 1202P provides dedicated surge and ESD
protection for RS-485 and other 12V lines in industrial
applications. It features high surge current capability
of 100A (tp=8/20us) and low clamping voltage making
them ideal for use in harsh transient environments.
This device is designed to replace mulitple discrete
components by integrating low capacitance, surgerated compensation diodes with a high power transient
voltage suppressor (TVS). Capacitance is limited to
12pF maximum to ensure correct signal transmission
on high-speed lines. Each TClamp1202P may be used
to protect up to two lines. A voltage bus operating up
to 12V can also be optionally protected.
The TClamp1202P is in a 5-pin SLP2020P5 package,
measuring 2.0 x 2.0mm with a nominal height of
0.60mm. The flow- through package design simplifies
PCB layout.
®
 Transient protection for high-speed data lines to






IEC 61000-4-2 (ESD) 20kV (air), 15kV (contact)
IEC 61000-4-4 (EFT) 40A (5/50ns)
IEC 61000-4-5 (Lightning) 100A (8/20μs)
Array of surge rated diodes with internal TVS Diode
Protects up to two lines
Low capacitance: (<12pF)
Operating voltage: 12V
Low leakage current
Solid-state silicon-avalanche technology
Mechanical Characteristics






SLP2020P5 Package
Pb-Free, Halogen Free, RoHS/WEEE Compliant
Lead Finish: NiPdAu
Molding Compound Flammability Rating: UL 94V-0
Marking : Marking code + Date Code
Packaging : Tape and Reel
Applications







Functional Circuit Diagram
Package Configuration
2.00
1
2
Pin 2
2.00
12V
Pin 1
RS-485 Surge Protection
RS-422 Surge Protection
Industrial Equipment
Remote Meter Readers
Automatic Teller Machines
Digital Surveillance Cameras
CAN-bus
Pin 3
0.60
Pin 4, 5, Tab
Revision 5/27/2015
Nominal Dimensions in mm (Bottom View)
1
www.semtech.com
TClamp1202P
PRELIMINARY
PROTECTION PRODUCTS
Absolute Maximum Rating
R ating
Symbol
Value
Units
Peak Pulse Power (tp = 10/1000μs), T=25°C
Pp k
300
Watts
Peak Pulse Current (tp = 10/1000 μs), T=25°C
IP P
12
A
Peak Pulse Current (tp = 8/20μs), T=25°C
IP P
100
A
VESD
+/- 20
+/- 15
kV
TJ
-55 to +125
°C
TSTG
-55 to +150
°C
ESD per IEC 61000-4-2 (Air)1
ESD per IEC 61000-4-2 (Contact)1
Operating Temperature
Storage Temperature
Electrical Characteristics (T=25oC unless otherwise specified)
Parameter
Symbol
Conditions
Minimum
Typical
Maximum
Units
12
V
18.5
V
Reverse Stand-Off Voltage
VRWM
Reverse Breakdown Voltage
V BR
It = 1mA
Pins 1, 2 or 3 to pins 4,
5, and Tab5
Reverse Leakage Current
IR
VRWM = 12V, T=25°C
Pins 1, 2 or 3 to pins 4,
5, and Tab5
0.100
μA
Reverse Leakage Current
IR
VRWM = 12V, T=125°C
Pins 1, 2 or 3 to pins 4,
5, and Tab5
0.500
μA
RDYN
tlp = 0.2 / 100ns
Pin 1 and 3
Clamping Voltage4
VC
IPP = 12A,
tp = 10/1000μs
Pins 1, 2 or 3 to pins 4,
5, and Tab5
25
V
Clamping Voltage4
VC
IPP = 100A, tp = 8/20μs
Pins 1, 2 or 3 to pins 4,
5, and Tab5
40
V
Junction Capacitance4
Cj
Pin 1 or 3 to pins 4, 5,
and Tab5
VR = 0V, f = 1MHz
12
pF
Dynamic Resistance2, 3
13.3
15
0.11
Ohms
Notes
1)ESD gun return path connected to ESD ground reference plane.
2)Transmission Line Pulse Test (TLP) Settings: tp = 100ns, tr = 0.2ns, ITLP and VTLP averaging window: t1 = 70ns to t2 = 90ns.
3) Dynamic resistance calculated from Ipp = 4A to Ipp = 16A
4)Guaranteed by design. Not production tested.
5)Pins 4, 5 and center tab are internally connected
© 2015 Semtech Corporation
2
www.semtech.com
TClamp1202P
PRELIMINARY
PROTECTION PRODUCTS
Typical Characteristics
Non-Repetitive Peak Pulse Power vs. Pulse Time
(VBus Pin 1)
Capacitance vs. Reverse Voltage
(Data Line Pins 1 and 3)
100
14
Junction Capacitance - CJ (pF)
Peak Pulse Power - PPP (kW)
TA = 25OC
10
1
12
10
8
6
4
2
f = 1 MHz
0
0
0.1
0.1
1
10
100
2
4
6
8
10
12
14
Reverse Voltage - VR (V)
1000
Pulse Duration - tp (µs)
Clamping Voltage vs. Peak Pulse Current
(10/1000us Pulse Waveform)
Clamping Voltage vs. Peak Pulse Current
(8/20us Pulse Waveform)
40
35
TX/RX (Pins 1 and 3)
20
Clamping Voltage - VC (V)
Clamping Voltage - VC (V)
25
VBus (Pin 2)
15
10
Waveform
Parameters:
tr = 10µs
td = 1000µs
5
TX/RX (Pins 1 and 3)
30
25
VBus (Pin 2)
20
15
10
Waveform
Parameters:
tr = 8µs
td = 20µs
5
0
0
0
2
4
6
8
10
12
14
0
20
Peak Pulse Current - IPP (A)
Forward Voltage vs. Peak Pulse Current
(8/20us Pulse Waveform)
60
80
100
120
TLP Characteristic
(Data Line Pins 1 and 3)
35
12
Transmission Line Pulse Test (TLP)
Settings:
tp = 100ns, tr = 0.2ns,
ITLP and VTLP averaging window:
t1 = 70ns to t2 = 90ns
30
10
TX/RX (Pins 1 and 3)
TLP Current (A)
Forward Voltage - V F (V)
40
Peak Pulse Current - IPP (A)
8
6
4
25
20
15
10
2
5
0
0
0
20
40
60
80
100
120
0
Peak Pulse Current - IPP (A)
© 2015 Semtech Corporation
5
10
15
20
25
TLP Voltage (V)
3
www.semtech.com
TClamp1202P
PRELIMINARY
PROTECTION PRODUCTS
Typical Characteristics
ESD Clamping (+8kV Contact per IEC 61000-4-2)
(Data Line Pins 1 and 3)
ESD Clamping (-8kV Contact per IEC 61000-4-2)
(Data Line Pins 1 and 3)
160
10
Measured with 50 Ohm scope input impedance, 2GHz bandwidth. Corrected for 50 Ohm, 20dB attenuator. ESD gun return path connected to ESD ground plane
140
120
-10
-30
Voltage (V)
Voltage (V)
100
80
60
-50
-70
40
-90
20
-110
0
-130
-20
Measured with 50 Ohm scope input impedance, 2GHz bandwidth. Corrected for 50 Ohm, 20dB attenuator. ESD gun return path connected to ESD ground plane
-150
-10
0
10
20
30
40
50
60
70
-10
80
0
10
20
ESD Clamping (+8kV Contact per IEC 61000-4-2)
(VBus Pin 2)
40
50
60
70
80
ESD Clamping (-8kV Contact per IEC 61000-4-2)
(VBus Pin 2)
20
100
Measured with 50 Ohm scope input impedance, 2GHz bandwidth. Corrected for 50 Ohm, 20dB attenuator. ESD gun return path connected to ESD ground plane
90
80
70
0
-20
60
Voltage (V)
Voltage (V)
30
Time (ns)
Time (ns)
50
40
30
-40
-60
20
10
Measured with 50 Ohm scope input impedance, 2GHz bandwidth. Corrected for 50 Ohm, 20dB attenuator. ESD gun return path connected to ESD ground plane
-80
0
-100
-10
-10
0
10
20
30
40
50
60
70
-10
80
0
10
LOG
30
40
50
60
70
80
Analog Crosstalk
(Pin 1 to 3)
Typical Insertion Loss S21
(Data Line Pins 1 and 3)
CH1 S21
20
Time (ns)
Time (ns)
CH1 S21
6 dB / REF 0 dB
LOG
20dB /REF 0 dB
1: - 7.4634 dB
800 MHz
0 dB
2: - 8.8858 dB
900 MHz
0 dB
3: - 6.2824 dB
1.8 GHz
-20 dB
5
-6 dB
4
3
1
-12 dB
2
-40 dB
4: - 4.1204 dB
2.5 GHz
-18 dB
-60 dB
5: - 4.1436 dB
2.7 GHz
-24 dB
-80 dB
-30 dB
-100 dB
-36 dB
-120 dB
-42 dB
-48 dB
-140 dB
1
MHz
START. 030 MHz
© 2015 Semtech Corporation
10
MHz
100
MHz
3
1
GHz GHz
-160 dB
START. 030 MHz
STOP 3000.000000 MHz
4
STOP 3000.000000 MHz
www.semtech.com
TClamp1202P
PRELIMINARY
PROTECTION PRODUCTS
Applications Information
mode protection, one of the TClamp1202P data pins
(pin 1 or 3) is connected to the TX/RX line and the
other is connected to ground. Pins 4 and 5 as well as
EIA RS-485 specifies a ±7V ground difference between
the center tab are not connected. This effectively
devices on the bus. This permits the bus voltage to
makes the device look like a bidirectional 12V TVS to
range from +12V (5V + 7V) to -7V (0 - 7V).
the circuit. For differential mode protection, each of
Because of this requirement, each TClamp1202P can
the device data pins (1 and 3) are connected to the
be configured to protect one line for common mode
transceiver RX/TX pins as shown. Again, Pins 4, 5 and
surges or one line pair for differential surges.
the center tab are not connected.
The example below illustrates how to connect the
TClamp1202P for common mode and differential
mode protection on an RS-485 interface. For common
Device Connection for Protection of RS-485 Interfaces
Receiver
TClamp1202P
TClamp1202P
R
Driver
TClamp1202P
RS-485 Common Mode and Differential Surge Protection
© 2015 Semtech Corporation
5
www.semtech.com
TClamp1202P
PRELIMINARY
PROTECTION PRODUCTS
Outline
OutlineDrawing
Drawing- -SO-8
SLP2020P5
A
B
D
DIMENSIONS
MILLIMETERS
MIN NOM MAX
DIM
E
PIN 1
INDICATOR
(LASER MARK)
A
SEATING
PLANE
aaa c
A2
A1
C
b1X3
bbb
C A B
A 0.50 0.60 0.65
A1 0.00 0.03 0.05
(0.127)
A2
b 0.20 0.25 0.30
b1 0.25 0.30 0.35
D 1.90 2.00 2.10
D1 0.775 0.925 1.025
E 1.90 2.00 2.10
E1 0.750 0.900 1.000
e
0.675 BSC
e1
0.725 BSC
L 0.25 0.30 0.35
N
5
aaa
0.08
bbb
0.08
D1
e1
R0.20
1
2
E/2
LxN
E1
N
bX2
bbb
e/2
C A B
e
D/2
NOTES:
1. CONTROLLING DIMENSIONS ARE IN MILLIMETERS (ANGLES IN DEGREES).
2. COPLANARITY APPLIES TO THE EXPOSED PAD AS WELL AS THE TERMINALS.
Land Pattern - SLP2020P5
P
b
DIMENSIONS
P/2
G
(C) K
Y
Z
DIM
C
G
H
K
P
P1
b
b1
Y
Z
MILLIMETERS
(1.95)
1.35
0.925
0.900
0.675
0.725
0.30
0.35
0.60
2.55
b1
P1
H
NOTES:
1. CONTROLLING DIMENSIONS ARE IN MILLIMETERS (ANGLES IN DEGREES).
2. THIS LAND PATTERN IS FOR REFERENCE PURPOSES ONLY.
CONSULT YOUR MANUFACTURING GROUP TO ENSURE YOUR
COMPANY'S MANUFACTURING GUIDELINES ARE MET.
© 2015 Semtech Corporation
6
www.semtech.com
TClamp1202P
PRELIMINARY
PROTECTION PRODUCTS
Marking Codes
PIN 1
INDICATOR
(LASER MARK)
Ordering Information
12P
YW
Part Number
Qty per
Reel
R eel Size
TClamp 1202P.TGT
10,000
13 Inch
TransClamp and TClamp are trademarks of Semtech Corporation.
YW = Alphanumeric character Date Code
Carrier Tape Specification