My-Com precision switches MY-COM B My-Com precision switches sample drawing M8 x 0,5 1,5 ø 1 ø 7,4 2 30 18 SW 10 ø 8 general data sample picture repeat accuracy < 0,001 mm mech. pre-run / overrun - / 1,5 mm approx. measurement type contact with medium direction of approach frontal electrical data DC voltage max. 15 VDC switch. current DC max. 2 mA AC voltage max. 24 VAC switch. current AC max. 50 mA output circuit break function (NC) mechanical mechanical data activating pin zirconium oxide ZrO2 housing material brass nickel plated dimension 8 mm type cylindrical threaded ambient conditions operating temperature -20 ... +75 °C protection class IP 50 order reference activating force connection types housing length MY-COM B100/80 100 cN cable, 80 cm 20 mm MY-COM B30/80 30 cN cable, 80 cm 20 mm MY-COM B50/80 50 cN cable, 80 cm 20 mm MY-COM B75/80 75 cN cable, 80 cm 20 mm MY-COM BS100 100 cN connector S30 30 mm MY-COM BS30 30 cN connector S30 30 mm MY-COM BS50 50 cN connector S30 30 mm MY-COM BS75 75 cN connector S30 30 mm 1 www.baumer.com 9/1/2014