© Siemens AG 2016 Flow Measurement SITRANS F C Flowmeter SITRANS FC430 ■ Overview ■ Technical specifications Sizes DN 15 (½"), DN 25 (1"), DN 50 (2"), DN 80 (3") Accuracy ± 0.10 % Repeatability ± 0.05 % Flow range (water @ 1 bar pressure loss) DN 15: 3 700 kg/h (8 157 lb/h) DN 25: 11 500 kg/h (25 353 lb/h) DN 50: 52 000 kg/h (114 640 lb/h) DN 80: 136 000 kg/h (300 000 lb/h) Architecture Compact or remote configuration Display Full graphical display, 240 x 160 pixels with selection of twelve languages including Chinese and Russian Power supply 20 ... 27 V DC ± 10%; 100 ... 240 V AC ± 10 %, 47 ... 63 Hz ± 10% Weight 4.6 ... 50 kg Material The complete flowmeter system SITRANS FC430 can be ordered for standard, hygienic or NAMUR service. All versions can be ordered for CT service, according to OIML R 117 (Liquids other than water) and NTEP. SIL specified compact variants can be validated and configured for SIL 2 or SIL 3 operation. SIL 3 operation requires two flowmeters in series and monitored by a SIL-rated control system. Series mounting must not introduce cross-talk between the sensors. Refer to installation guidelines. The flowmeter is based on the latest developments within digital signal processing technology – engineered for high measuring performance: • Fast response to rapid changes in flow • Fast dosing applications • High immunity against process noise • High turndown ratio of flowrates • Suitable for liquid and gas service • Easy to install, commission and maintain • Sensor - Wetted parts - Enclosure • Transmitter Enclosure rating 316L stainless steel or Hastelloy C22 304 stainless steel Aluminum with corrosion-resistant coating IP67 Pressure ratings • Measuring tubes - 316L - Hastelloy C22 • Sensor enclosure 100 bar (1450 psi) 160 bar (2321 psi) 20 bar (DN15, DN 25) 17 bar (DN 50, DN 80) • Sensor enclosure burst pressure >160 bar (all sizes) Temperature ratings • Process medium -50 ... +200 °C (-58 ... +392 °F) • Ambient -40 ... +60 °C (-40 ... +140 °F) • Display -20 ... +60 °C (-4 ... +140 °F) Process connections • Flanges EN 1092-1 B1, EN 1092-1 D, ANSI/ASME B16.5, JIS B 2220, DIN 11864-2 • Pipe threads ASME B1.20 (NPT), ISO228-1 G (BSPP), VCO Quick-connect The transmitter comes with a user-configurable graphical display and SensorFlash, a micro SD card for configuration backup, firmware update and data storage. • Hygienic threads DIN 11851, DIN 11864-1A, ISO 2853, SMS 1145 • Hygienic clamps DIN 11864-3A, DIN 32676, ISO 2852 The SITRANS FC430 flowmeter system consists of a SITRANS FCS400 sensor and a SITRANS FCT030 transmitter. Approvals FC430 is available as standard with 4 to 20 mA analog output with HART 7.2. Additional functions can be freely configured for analog, pulse, frequency, relay or status output or binary input. ■ Benefits • It is compact and light, fitting neatly into dense piping arrangements • Easy maintenance because modules can be exchanged rapidly • Effective separation of measurement from plant vibration • Highly secure operation in safety critical applications • Non-volatile memory of all setup and operation data • Reliable measurements due to high signal to noise ratio • Secure, digital transfer of measurement data from the sensor • Short overall length; easy drop-in replacement into most existing installations • Functional Safety (SIL X). Device suitable for use in accordance with IEC 61508 and IEC 61511. • Hazardous area ATEX, IECEx, EAC Ex, FM, NEPSI, CSA, INMETRO • Pressure equipment PED, CRN • Hygienic 3A, EHEDG • Custody transfer OIML R 117, NTEP • Operational safety (compact system only) SIL 2 Single SIL 3 Redundant system NAMUR NAMUR-compliant (e.g. NE 21, NE 41, NE 107 and NE 132) I/O Up to 4 channels combining analog, relay or digital outputs and binary input Communication HART 7.2 EMC performance Emission EN 55011/CISPR-11 (Class A) Immunity EN/IEC 61236-1 (Industry) Mechanical load 18 to 400 Hz random The flow meter will mechanically tolerate 3.17 g RMS in all directions. Flow accuracy cannot be guaranteed under all conditions. Siemens FI 01 · 2016 3/161 3 © Siemens AG 2016 Flow Measurement SITRANS F C Flowmeter SITRANS FC430 Selection and Ordering data Article No. SITRANS FC430 Digital coriolis flowmeter with SITRANS FCS400 Standard flow sensor with hygienic and flange/pipe thread connections and compact or remote mounting with FCT030 transmitter 7 ME 4 6 1 3 - Ord. code 7777 7 - 7 7 7 7 7 7 7 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. 3 Sensor size, connection size DN 15, DN 10 (½", 3/8") DN 15, DN 15 (½", ½") DN 15, DN 20 (½", ¾") DN 15, DN 25 (½", 1") 3F 3G 3H 3J DN 25, DN 15 (1", ½") DN 25, DN 25 (1", 1") DN 25, DN 40 (1", 1½") 3K 3L 3N DN 50, DN 40 (2", 1½") DN 50, DN 50 (2", 2") 4B 4C DN 80, DN 65 (3", 2½") DN 80, DN 80 (3", 3") DN 80, DN 100 (3", 4") 4J 4K 4L Process connection EN 1092-1 B1, PN 16 EN 1092-1 B1, PN 40 EN 1092-1 B1, PN 63 EN 1092-1 B1, PN 100 EN 1092-1 B1, PN 160 EN 1092-1 D NUT, PN 40 EN 1092-1 D NUT, PN 63 EN 1092-1 D NUT, PN 100 EN 1092-1 D NUT, PN 160 E1 E3 DIN 11851 hygienic screwed F1 DIN 32676 hygienic Tri-Clamp G1 DIN 11864-1A asceptic screwed DIN 11864-2A asceptic flanged DIN 11864-3A clamped H1 H2 H3 ISO 2852 hygienic clamped ISO 2853 hygienic screwed J1 J5 3/162 Siemens FI 01 · 2016 A C F H M N P Q U 1 3 Order code Please add "-Z" to Article No. and specify Order code(s). Cable glands Metric, no glands Metric, plastic D1 D2 D3 D4 A01 A02 Metric, brass/Ni plated Metric, stainless steel NPT, no glands A05 A06 A11 NPT, Plastic NPT, brass/Ni plated NPT, stainless steel A12 A15 A16 Sofware functions and CT approvals Standard CT standard CT with NTEP B11 B31 B52 I/O configuration Ch1 Ca 4 ... 20 mA HART active SIL certified Cp 4 ... 20 mA HART passive SIL certified Ca 4 ... 20 mA HART active Cp 4 ... 20 mA HART passive E04 E05 E06 E07 Options for Ex ATEX + IECEx + EAC Ex Only compact versions can be used in SIL applications. Wetted parts material Transmitter/DSL material & mounting style Compact, IP67, aluminum Remote, IP67, aluminum, M12 Remote, IP67, aluminum, T/Box Further designs K1 K5 L2 L4 L6 L7 7 77 7 7 - 7 7 7 7 7 7 7 Selection and Ordering data A0 A1 A2 A3 B1 A5 A6 A7 A8 Calibration/Accuracy class 0.1 % flow, 5 kg/m³ density 0.1 % flow, 0.5 kg/m³ density Standard fraction calibration Ord. code We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. ISO228-1 G pipe thread ASME B1.20.1 NPT pipe thread AISI 316L/W1.4435/W1.4404 (100 barg max.) Hastelloy C22 (only for 7ME461) 7 ME 4 6 1 3 - Local User Interface Blind Graphical, 240 x 160 pxl SMS 1145 hygienic screwed 12-VCO-4 quick connect JIS B2200:2004/10K JIS B2220:2004/20K JIS B2220:2004/40K JIS B2220:2004/63K Article No. Ex approval Non-Ex ATEX IECEx FM CSA NEPSI INMETRO KCs EAC ANSI B16.5-2009, class 150 ANSI B16.5-2009, class 300 ANSI B16.5-2009, class 600 ANSI B16.5-2009, class 900 Selection and Ordering data SITRANS FC430 Digital coriolis flowmeter with SITRANS FCS400 Standard flow sensor with hygienic and flange/pipe thread connections and compact or remote mounting with FCT030 transmitter 1 3 1 4 8 D G K Q0B © Siemens AG 2016 Flow Measurement SITRANS F C Flowmeter SITRANS FC430 Selection and Ordering data Order code I/O configuration Ch2, Ch3 and Ch4 None Order code Selection and Ordering data Add-on options and accessories F00 Please add "-Z" to Article No. and specify Order code(s). aSignal, None, None aSignal, aSignal, None aSignal, aSignal, aSignal F40 F41 F42 aSignal, aSignal, Ia aSignal, aSignal, R aSignal, Ia, None F43 F44 F45 aSignal, Ia, Ia aSignal, Ia, R aSignal, R, None F46 F47 F50 aSignal, R, R pSignal, None, None pSignal, pSignal, None F51 F60 F61 pSignal, pSignal, pSignal pSignal, pSignal, Ip pSignal, pSignal, R F62 F63 F64 pSignal, Ip, None pSignal, Ip, Ip pSignal, Ip, R F65 F66 F67 pSignal, R, None pSignal, R, R aSignal, aSignal, pSignal F70 F71 F80 aSignal, aSignal, Ip aSignal, pSignal, None aSignal, pSignal, pSignal F81 F82 F83 aSignal, pSignal, Ia aSignal, pSignal, Ip aSignal, pSignal, R F84 F85 F86 Region-specific approvals and certificates aSignal, Ia, Ip aSignal, Ip, None aSignal, Ip, Ip F87 F90 F91 Additional data aSignal, Ip, R pSignal, pSignal, Ia pSignal, Ia, None F92 F93 F94 Tag name pSignal, Ia, Ia pSignal, Ia, Ip pSignal, Ia, R F95 F96 F97 Notes on I/O configurations: a or p suffix: The I/O module is selected at ordering with either active or passive function. Signal: The output can be selected for Current (0 or 4 to 20 mA), frequency or pulse function in the menu. I: Discrete status input to the flowmeter. Functions are selected in the menu including 'Freeze output', ’Reset totalizer'. R: Relay output for discrete status reporting. Function is selected in the menu, including 'Error', 'High flow warning'. The MLFB structure for FC430 systems must be filled to this level, including "-Z" options A.., B.., E.. and F.. Certificates Pressure test certificate CRN Pressure test certificate PED Material certificate EN 10204-3.1 C01 C02 C05 Welding inspection report Factory certificate to EN 10204 2.1 Factory certificate to EN 10204 2.2 Cleaning for oil and grease C07 C10 C11 C50 3 Cable None L50 5 m (16.4 ft), standard with M12 plugs fitted 5 m (16.4 ft), standard L51 L52 10 m (32.8 ft) standard with M12 plugs fitted 10 m (32.8 ft), standard L55 L56 25 m (82 ft), standard with M12 plugs fitted 25 m (82 ft), standard L59 L60 50 m (164 ft), standard with M12 plugs fitted 50 m (164 ft), standard L63 L64 75 m (246 ft), standard with M12 plugs fitted 75 m (246 ft), standard L67 L68 150 m (492 ft), standard with M12 plugs fitted 150 m (492 ft), standard L71 L72 South Korea (KCC) W28 Please add "-Z" to Article No. and specify Order code(s) and plain text. Tag name plate, stainless steel Y17 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Operating instructions for SITRANS FC430 Description Article No. • English A5E03361511 • German A5E03651143 This device is shipped with a Quick Start guide and a CD containing further SITRANS F C literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Siemens FI 01 · 2016 3/163 © Siemens AG 2016 Flow Measurement SITRANS F C Flowmeter SITRANS FC430 Selection and Ordering data Article No. SITRANS FC430 Digital coriolis flowmeter 7 ME 4 6 2 3 - Ord. code Further designs with SITRANS FCS400 Flow sensor Hygienic version with Ra < 0.8 m, 3A approved, and compact or remote mounting with FCT030 transmitter 7 77 7 7 - 7 7 7 7 7 7 7 Please add "-Z" to Article No. and specify Order code(s). Click on the Article No. for the online configuration in the PIA Life Cycle Portal. 3 Sensor size, connection size DN 15, DN 10 (½", 3/8") DN 15, DN 15 (½", ½") DN 15, DN 20 (½", ¾") DN 15, DN 25 (½", 1") 3F 3G 3H 3J DN 25, DN 25 (1", 1") DN 25, DN 32 (1", 1¼") DN 25, DN 40 (1", 1½") 3L 3M 3N DN 50, DN 40 (2", 1½") DN 50, DN 50 (2", 2") 4B 4C DN 80, DN 65 (3", 2½") DN 80, DN 80 (3", 3") 4J 4K Process connection DIN 11851 0.8 µm hygienic screwed F1 DIN 32676 0.8 µm hygienic Tri-Clamp G1 DIN 11864-1 0.8 µm hygienic screwed DIN 11864-2A BF-A 0.8 µm hygienic screwed (metric) DIN 11864-3A BF-A 0.8 µm hygienic clamped DIN 11864-2B BF-A 0.8 µm hygienic flanged (NPS) H1 H2 J1 J5 ISO 2852 0.8 µm hygienic clamped ISO 2853 0.8 µm hygienic screwed Calibration/Accuracy class 0.1 % flow, 5 kg/m³ density 0.1 % flow, 0.5 kg/m³ density Standard fraction calibration Transmitter/DSL material and mounting style Compact, IP67, aluminum Remote, IP67, aluminum, M12 Remote, IP67, aluminum, T/Box Ex approval Non-Ex ATEX II 2GD IECEx GDb FM, Class 1, Div 1 CSA, Class 1, Zone 1 NEPSI INMETRO KCs EAC Local User Interface Blind Graphical, 240 x 160 pxl Siemens FI 01 · 2016 A01 A02 A05 A06 A11 A12 A15 A16 Sofware functions and CT approvals Standard CT standard CT with NTEP B11 B31 B52 I/O configuration Ch1 Ca 4 ... 20 mA HART active SIL certified Cp 4 ... 20 mA HART passive SIL certified Ca 4 ... 20 mA HART active Cp 4 ... 20 mA HART passive Only compact versions can be used in SIL applications. H3 H4 1 1 4 8 D G K A C F H M N P Q U 1 3 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. 3/164 Cable glands Metric, no glands Metric, plastic Metric, brass/Ni plated Metric, stainless steel NPT, no glands NPT, plastic NPT, brass/Ni plated NPT, stainless steel Options for Ex ATEX + IECEx + EAC Ex Wetted parts material AISI 316L/1.4435 (40 bar max.) Order code Selection and Ordering data E04 E05 E06 E07 Q0B © Siemens AG 2016 Flow Measurement SITRANS F C Flowmeter SITRANS FC430 Selection and Ordering data Order code I/O configuration Ch2, Ch3 and Ch4 None Order code Selection and Ordering data Add-on options and accessories F00 Please add "-Z" to Article No. and specify Order code(s). aSignal, None, None aSignal, aSignal, None aSignal, aSignal, aSignal F40 F41 F42 aSignal, aSignal, Ia aSignal, aSignal, R aSignal, Ia, None F43 F44 F45 aSignal, Ia, Ia aSignal, Ia, R aSignal, R, None F46 F47 F50 aSignal, R, R pSignal, None, None pSignal, pSignal, None F51 F60 F61 pSignal, pSignal, pSignal pSignal, pSignal, Ip pSignal, pSignal, R F62 F63 F64 pSignal, Ip, None pSignal, Ip, Ip pSignal, Ip, R F65 F66 F67 pSignal, R, None pSignal, R, R aSignal, aSignal, pSignal F70 F71 F80 aSignal, aSignal, Ip aSignal, pSignal, None aSignal, pSignal, pSignal F81 F82 F83 aSignal, pSignal, Ia aSignal, pSignal, Ip aSignal, pSignal, R F84 F85 F86 Region-specific approvals and certificates aSignal, Ia, Ip aSignal, Ip, None aSignal, Ip, Ip F87 F90 F91 Additional data aSignal, Ip, R pSignal, pSignal, Ia pSignal, Ia, None F92 F93 F94 Tag name pSignal, Ia, Ia pSignal, Ia, Ip pSignal, Ia, R F95 F96 F97 Notes on I/O configurations: a or p suffix: The I/O module is selected at ordering with either active or passive function. Signal: The output can be selected for Current (0 or 4 to 20 mA), frequency or pulse function in the menu. I: Discrete status input to the flowmeter. Functions are selected in the menu including 'Freeze output', ’Reset totalizer'. R: Relay output for discrete status reporting. Function is selected in the menu, including 'Error', 'High flow warning'. The MLFB structure for FC430 systems must be filled to this level, including "-Z" options A.., B.., E.. and F.. Certificates Pressure test certificate CRN Pressure test certificate PED Material certificate EN 10204-3.1 C01 C02 C05 Welding inspection report Factory certificate to EN 10204 2.1 Factory certificate to EN 10204 2.2 Cleaning for oil and grease C07 C10 C11 C50 3 Cable None 5 m (16.4 ft), standard with M12 plugs fitted 5 m (16.4 ft), standard L50 L51 L52 10 m (32.8 ft) standard with M12 plugs fitted 10 m (32.8 ft), standard L55 L56 25 m (82 ft), standard with M12 plugs fitted 25 m (82 ft), standard L59 L60 50 m (164 ft), standard with M12 plugs fitted 50 m (164 ft), standard L63 L64 75 m (246 ft), standard with M12 plugs fitted 75 m (246 ft), standard L67 L68 150 m (492 ft), standard with M12 plugs fitted 150 m (492 ft), standard L71 L72 South Korea (KCC) W28 Please add "-Z" to Article No. and specify Order code(s) and plain text. Tag name plate, stainless steel Y17 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Operating instructions for SITRANS FC430 Description Article No. • English A5E03361511 • German A5E03651143 This device is shipped with a Quick Start guide and a CD containing further SITRANS F C literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Siemens FI 01 · 2016 3/165 © Siemens AG 2016 Flow Measurement SITRANS F C Flowmeter SITRANS FC430 Selection and Ordering data Article No. Selection and Ordering data Article No. SITRANS FC430 Digital coriolis flowmeter 7 ME 4 7 1 3 - Ord. code SITRANS FC430 Digital coriolis flowmeter 7 ME 4 7 1 3 - with SITRANS FCS400 NAMUR complient flow sensor with flange/pipe thread connections and compact or remote mounting with FCT030 transmitter 7 77 7 7 - 7 7 7 7 7 7 7 with SITRANS FCS400 NAMUR complient flow sensor with flange/pipe thread connections and compact or remote mounting with FCT030 transmitter 7777 7 - 7 7 7 7 7 7 7 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. 3 Sensor size, Connection size DN 15, DN 6 (½", ¼") DN 15, DN 10 (½", 3/8") DN 15, DN 15 (½", ½") DN 15, DN 20 (½", ¾") DN 15, DN 25 (½", 1") DN 25, DN 25 (1", 1") DN 25, DN 32 (1", 1¼") DN 25, DN 40 (1", 1½") 3L 3M 3N DN 50, DN 40 (2", 1½") DN 50, DN 50 (2", 2") 4B 4C DN 80, DN 65 (3", 2½") DN 80, DN 80 (3", 3") DN 80, DN 100 (3", 4") 4J 4K 4L Process connection EN 1092-1 B1, PN 16 EN 1092-1 B1, PN 40 EN 1092-1 B1, PN 63 EN 1092-1 B1, PN 100 EN 1092-1 B1, PN 160 Ex approval Non-Ex ATEX II 2GD IECEx GDb FM, Class 1, Div 1 CSA, Class 1, Zone 1 NEPSI INMETRO KCs EAC 3E 3F 3G 3H 3J Local User Interface Blind Graphical, 240 x 160 pxl A0 A1 A2 A3 B1 D1 D2 D3 D4 ISO228-1 G pipe thread ASME B1.20.1 NPT pipe thread E1 E3 DIN 11851 Hygienic screwed F1 DIN 32676-C (inch) Hygienic clamped G1 DIN 11864-1 Hygienic screwed DIN 11864-2A BF-A Hygienic flanged metric DIN 11864-3A Hygienic clamped DIN 11864-2B BF-A Hygienic flanged NPS H1 H2 H3 H4 ISO 2852 Hygienic clamped ISO 2853 Hygienic screwed J1 J5 Order code Please add "-Z" to Article No. and specify Order code(s). Transmitter/DSL material & mounting style Compact, IP67, aluminum Remote, IP67, aluminum, M12 Remote, IP67, aluminum, T/Box A01 A02 A05 A06 A11 A12 A15 A16 Sofware functions and CT approvals Standard CT standard CT with NTEP B11 B31 B52 I/O configuration Ch1 Ca 4 ... 20 mA HART active, SIL certified Cp 4 ... 20 mA HART passive, SIL certified Ca 4 ... 20 mA HART active Cp 4 ... 20 mA HART passive Only compact versions can be used in SIL applications. K1 K5 Wetted parts material AISI 316L/W1.4435/W1.4404 (100 barg max.) Hastelloy C22 Cable glands Metric, no glands Metric, plastic Metric, brass/Ni plated Metric, stainless steel NPT, no glands NPT, plastic NPT, brass/Ni plated NPT, stainless steel Options for Ex ATEX + IECEx + EAC Ex L2 L4 L6 L7 JIS B2200/10K JIS B2200/20K JIS B2200/40K JIS B2200/63K Siemens FI 01 · 2016 1 3 Further designs A5 A6 A7 A8 3/166 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. ANSI B16.5, RF, class 150 ANSI B16.5, RF, class 300 ANSI B16.5, RF, class 600 ANSI B16.5, RF, class 900 Calibration/Accuracy class 0.1 % flow, 5 kg/m³ density 0.1 % flow, 0.5 kg/m³ density Standard fraction calibration A C F H M N P Q U Selection and Ordering data EN 1092-1 D, PN 40 EN 1092-1 D, PN 63 EN 1092-1 D, PN 100 EN 1092-1 D, PN 160 SMS 1145 Hygienic screwed Swagelok Quick Connect Ord. code 1 3 1 4 8 D G K E04 E05 E06 E07 Q0B © Siemens AG 2016 Flow Measurement SITRANS F C Flowmeter SITRANS FC430 Selection and Ordering data Order code I/O configuration Ch2, Ch3 and Ch4 None Order code Selection and Ordering data Add-on options and accessories F00 Please add "-Z" to Article No. and specify Order code(s). aSignal, None, None aSignal, aSignal, None aSignal, aSignal, aSignal F40 F41 F42 aSignal, aSignal, Ia aSignal, aSignal, R aSignal, Ia, None F43 F44 F45 aSignal, Ia, Ia aSignal, Ia, R aSignal, R, None F46 F47 F50 aSignal, R, R pSignal, None, None pSignal, pSignal, None F51 F60 F61 pSignal, pSignal, pSignal pSignal, pSignal, Ip pSignal, pSignal, R F62 F63 F64 pSignal, Ip, None pSignal, Ip, Ip pSignal, Ip, R F65 F66 F67 pSignal, R, None pSignal, R, R aSignal, aSignal, pSignal F70 F71 F80 aSignal, aSignal, Ip aSignal, pSignal, None aSignal, pSignal, pSignal F81 F82 F83 aSignal, pSignal, Ia aSignal, pSignal, Ip aSignal, pSignal, R F84 F85 F86 Region-specific approvals and certificates aSignal, Ia, Ip aSignal, Ip, None aSignal, Ip, Ip F87 F90 F91 Additional data aSignal, Ip, R pSignal, pSignal, Ia pSignal, Ia, None F92 F93 F94 Tag name pSignal, Ia, Ia pSignal, Ia, Ip pSignal, Ia, R F95 F96 F97 Notes on I/O configurations: a or p suffix: The I/O module is selected at ordering with either active or passive function. Signal: The output can be selected for Current (0 or 4 to 20 mA), frequency or pulse function in the menu. I: Discrete status input to the flowmeter. Functions are selected in the menu including 'Freeze output', ’Reset totalizer'. R: Relay output for discrete status reporting. Function is selected in the menu, including 'Error', 'High flow warning'. The MLFB structure for FC430 systems must be filled to this level, including "-Z" options A..., B..., E... and F... Certificates Pressure test certificate CRN Pressure test certificate PED Material certificate EN 10204-3.1 C01 C02 C05 Welding inspection report Factory certificate to EN 10204 2.1 Factory certificate to EN 10204 2.2 Cleaning for oil and grease C07 C10 C11 C50 3 Cable None 5 m (16.4 ft), standard with M12 plugs fitted 5 m (16.4 ft), standard L50 L51 L52 10 m (32.8 ft) standard with M12 plugs fitted 10 m (32.8 ft), standard L55 L56 25 m (82 ft), standard with M12 plugs fitted 25 m (82 ft), standard L59 L60 50 m (164 ft), standard with M12 plugs fitted 50 m (164 ft), standard L63 L64 75 m (246 ft), standard with M12 plugs fitted 75 m (246 ft), standard L67 L68 150 m (492 ft), standard with M12 plugs fitted 150 m (492 ft), standard L71 L72 South Korea (KCC) W28 Please add "-Z" to Article No. and specify Order code(s) and plain text. Tag name plate, stainless steel Y17 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Operating instructions for SITRANS FC430 Description Article No. • English A5E03361511 • German A5E03651143 This device is shipped with a Quick Start guide and a CD containing further SITRANS F C literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Siemens FI 01 · 2016 3/167 © Siemens AG 2016 Flow Measurement SITRANS F C Flowmeter - Accessories/Spare parts Accessories Description Article No. Description CT plug Tamper cover for CT locking. Fits over the M12 plug at both sensor and transmitter ends of the remote system cable (2 pcs.) A5E31478498 Standard cable (Ex) with M12 plugs, PO insulation and PUR sleeve, blue, -40 ... +80 °C (-40 ... +176 °F) Bag of glands (metric) in black plastic1) A5E03907414 Bag of glands, (metric) in gray plastic Ex e/i1) A5E03907424 Bag of glands (metric) in AISI 316 SS Ex e/i1) A5E03907429 Bag of glands (metric) in Ni-plated brass Ex e/i1) A5E03907430 Bag of glands (NPT) in black plastic2) Bag of glands (NPT) in gray plastic Ex e/i2) Article No. •5m A5E03914929 • 10 m A5E03914962 • 25 m A5E03914995 • 50 m A5E03915004 • 75 m A5E03915074 • 150 m A5E03915088 3 Standard cable (Ex) for termination, PO insulation and PUR sleeve, blue, -40 ... +80 °C (-40 ... +176 °F) A5E03907435 A5E03907451 Bag of glands (NPT) in AISI 316 SS Ex e/i2) A5E03907467 Bag of glands (NPT) in Ni-plated brass Ex e/i2) A5E03907473 Standard cable (non-Ex) with M12 plugs, PO insulation and PUR sleeve, gray, -40 ... +80 °C (-40 ... +176 °F) • 5 m (16.4 ft) A5E03914805 • 10 m (32.8 ft) A5E03914850 • 25 m (82 ft) A5E03914853 • 50 m (164 ft) A5E03914859 • 75 m (246 ft) A5E03914861 • 150 m (492 ft) A5E03914874 •5m A5E03914945 • 10 m A5E03914973 • 25 m A5E03914984 • 50 m A5E03915015 • 75 m A5E03915057 • 150 m A5E03915100 Suitcase for comprehensive sales support and training for FC430 It comes in a special suitcase with a fan implemented that allows the flowmeter to demonstrate airflow. A5E31467598 Suitcase for comprehensive sales support and training for FC410. It comes in a special suitcase with an S7-1200 PLC and HMI touch-screen display. The operating code is open-source and can be copied to customers to assist with system integration. A5E33219071 Service toolkit for field maintenance of transmitter and sensor components. Contains all hand tools necessary for maintenance. Other tools may be required for installation. A5E03722877 Standard cable (non-Ex) for termination, PO insulation and PUR sleeve, gray, -40 ... +80 °C (-40 ... +176 °F) • 5 m (16.4 ft) A5E03914833 • 10 m (32.8 ft) A5E03914849 • 25 m (82 ft) A5E03914854 • 50 m (164 ft) A5E03914856 • 75 m (246 ft) A5E03914864 • 150 m (492 ft) A5E03914873 Siemens FI 01 · 2016 3/179 © Siemens AG 2016 Flow Measurement SITRANS F C Flowmeter - Accessories/Spare parts Article No. Description Heating Jacket, indoor use, 0 ... 200 °C (32 ... 392 °F) max. temperature. Complete with 5 m (16.4 ft) high temperature cable fitted. Dedicated plug connection to included controller Description Dimension Article No. DN 10 FDK:085U1016 DN 15 FDK:085U1017 DN 25 FDK:085U1019 DN 32 FDK:085U1020 DN 40 FDK:085U1021 DN 50 FDK:085U1022 DN 65 FDK:085U1023 25 mm FDK:085U1029 40 mm FDK:085U1031 50 mm FDK:085U1032 DN 10 FDK:085U1006 DN 15 FDK:085U1007 DN 25 FDK:085U1009 DN 32 FDK:085U1010 DN 40 FDK:085U1011 DN 50 FDK:085U1012 DN 65 FDK:085U1013 Mating parts for hygienic fittings DIN 11851 Includes: • 2 unions • 2 mating parts (for welding in) • 2 EPDM gaskets • 230 V AC 3 - DN 15 electric A5E33035287 - DN 25 electric A5E33035324 - DN 50 electric A5E33035325 - DN 80 electric A5E33035336 • 115 V AC - DN 15 electric A5E32877520 - DN 25 electric A5E32877556 - DN 50 electric A5E32877557 - DN 80 electric A5E32877561 Heating jacket controller, IP65. Digital display for 0 ... 200 °C (32 .. 392 °F) control setpoint • 230 V AC A5E03839193 • 115 V AC A5E03839194 1) 2 pcs M20; 1 pce M25 with single and dual cable inserts 2) 2 pcs ½" NPT; 1 pce ½" NPT with single and dual cable inserts Mating parts for hygienic clamp ISO 2852 Includes: • 2 clamps • 2 mating parts • 2 EPDM gaskets 2 EPDM gaskets with collar for mounting set DIN 11851 3/180 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F C Flowmeter - Accessories/Spare parts Spare parts - transmitter FCT030 Article No. Description Article No. Display and keypad assembly with firewire connection to the transmitter module1) A5E03548971 Mounting bracket - FCT030; in painted aluminum for pipe or wall mounting of transmitter FCT030 remote version. Including lock ring, pressure pads and seal cap A5E03906091 Sensor interface (Compact). Front end flow calculator and process detection. SIL 3 approved1) A5E03549142 M12 option for sensor housing in stainless steel. Prewired and potted to replace M12 socket in DSL housing A5E03906095 A5E03549098 M12 option - remote - in painted aluminum. Prewired and potted replacement M12 connection for FCT030 transmitter remote version A5E03906104 Sensor interface (Remote); barrier unit for high speed digital communication and Ex ib power supply to remote front end DSL module Remote terminal house M20 A5E03906112 Display lid in painted aluminum with Ex glass plate and o-ring seal A5E03549344 Remote terminal house NPT - in painted aluminum for sensor cable termination at FCT030 transmitter remote version. Pre-wired and potted A5E03906130 Transmitter cassette (active) with SIL approved 4 ... 20 mA output and HART 7.21) A5E03549357 Transmitter cassette (passive) with SIL approved 4 ... 20 mA output and HART 7.21) A5E03549383 Bag of loose spare parts; including cable strain relief components, mounting tool, seals and gasket, assorted screws and washers, hex cap nut, blind plugs, and o-rings A5E03549396 Power supply 240 V AC, 47 ... 63 Hz 24 ... 90 V DC A5E03549413 Blind lid in painted aluminum with o-ring seal A5E03549429 Description 3 Spare parts - sensor FCS400 I/O assembly Advise Order code F00 to F97 from Selection and Ordering data2) A5E03939114 SensorFlash (micro SD card) A5E03915258 Description Article No. Blind lid in painted aluminum with o-ring seal A5E03549295 Frontend cassette Spare part frontend cassette for remote version of FC430 and cassette for FC4101) A5E03549191 Sensor housing metric A5E03549313 Sensor housing NPT in painted aluminum A5E03906080 Bag of loose parts for sensor; including cable strain relief components, washer, seals, o-rings, and assorted screws A5E03549324 1) The system firmware bundle must be stated in the "Remark" field when ordering, to ensure compatibility of the system. The FW revision is found on the product label for FC430 and FC410. Further for FC430 the firmware bundle can be found in the local display in the menu items 3.1.10. e.g. "2.02.01-02" 2) The I/O configuration must be stated in the "Remark" field. The I/O configuration is found in the F option of the ordering code. e.g. code “F40” for ordering Ch2 Active Current/Freq/Pulse, Ch3 Active Current/Freq/Pulse, Ch4 Active Input Siemens FI 01 · 2016 3/181