SITRANS FC430 Coriolis flow meter catalog sheet

© Siemens AG 2016
Flow Measurement
SITRANS F C
Flowmeter SITRANS FC430
■ Overview
■ Technical specifications
Sizes
DN 15 (½"), DN 25 (1"),
DN 50 (2"), DN 80 (3")
Accuracy
± 0.10 %
Repeatability
± 0.05 %
Flow range
(water @ 1 bar pressure loss)
DN 15: 3 700 kg/h (8 157 lb/h)
DN 25: 11 500 kg/h (25 353 lb/h)
DN 50: 52 000 kg/h (114 640 lb/h)
DN 80: 136 000 kg/h (300 000 lb/h)
Architecture
Compact or remote configuration
Display
Full graphical display, 240 x 160 pixels
with selection of twelve languages
including Chinese and Russian
Power supply
20 ... 27 V DC ± 10%;
100 ... 240 V AC ± 10 %,
47 ... 63 Hz ± 10%
Weight
4.6 ... 50 kg
Material
The complete flowmeter system SITRANS FC430 can be ordered for standard, hygienic or NAMUR service. All versions can
be ordered for CT service, according to OIML R 117 (Liquids
other than water) and NTEP.
SIL specified compact variants can be validated and configured
for SIL 2 or SIL 3 operation. SIL 3 operation requires two flowmeters in series and monitored by a SIL-rated control system. Series mounting must not introduce cross-talk between the sensors. Refer to installation guidelines.
The flowmeter is based on the latest developments within digital
signal processing technology – engineered for high measuring
performance:
• Fast response to rapid changes in flow
• Fast dosing applications
• High immunity against process noise
• High turndown ratio of flowrates
• Suitable for liquid and gas service
• Easy to install, commission and maintain
• Sensor
- Wetted parts
- Enclosure
• Transmitter
Enclosure rating
316L stainless steel or Hastelloy C22
304 stainless steel
Aluminum with corrosion-resistant
coating
IP67
Pressure ratings
• Measuring tubes
- 316L
- Hastelloy C22
• Sensor enclosure
100 bar (1450 psi)
160 bar (2321 psi)
20 bar (DN15, DN 25)
17 bar (DN 50, DN 80)
• Sensor enclosure burst pressure >160 bar (all sizes)
Temperature ratings
• Process medium
-50 ... +200 °C (-58 ... +392 °F)
• Ambient
-40 ... +60 °C (-40 ... +140 °F)
• Display
-20 ... +60 °C (-4 ... +140 °F)
Process connections
• Flanges
EN 1092-1 B1, EN 1092-1 D,
ANSI/ASME B16.5, JIS B 2220,
DIN 11864-2
• Pipe threads
ASME B1.20 (NPT), ISO228-1 G
(BSPP), VCO Quick-connect
The transmitter comes with a user-configurable graphical display and SensorFlash, a micro SD card for configuration backup,
firmware update and data storage.
• Hygienic threads
DIN 11851, DIN 11864-1A,
ISO 2853, SMS 1145
• Hygienic clamps
DIN 11864-3A, DIN 32676, ISO 2852
The SITRANS FC430 flowmeter system consists of a
SITRANS FCS400 sensor and a SITRANS FCT030 transmitter.
Approvals
FC430 is available as standard with 4 to 20 mA analog output
with HART 7.2. Additional functions can be freely configured for
analog, pulse, frequency, relay or status output or binary input.
■ Benefits
• It is compact and light, fitting neatly into dense piping
arrangements
• Easy maintenance because modules can be exchanged
rapidly
• Effective separation of measurement from plant vibration
• Highly secure operation in safety critical applications
• Non-volatile memory of all setup and operation data
• Reliable measurements due to high signal to noise ratio
• Secure, digital transfer of measurement data from the sensor
• Short overall length; easy drop-in replacement into most existing installations
• Functional Safety (SIL X). Device suitable for use in
accordance with IEC 61508 and IEC 61511.
• Hazardous area
ATEX, IECEx, EAC Ex, FM, NEPSI,
CSA, INMETRO
• Pressure equipment
PED, CRN
• Hygienic
3A, EHEDG
• Custody transfer
OIML R 117, NTEP
• Operational safety
(compact system only)
SIL 2 Single
SIL 3 Redundant system
NAMUR
NAMUR-compliant (e.g. NE 21,
NE 41, NE 107 and NE 132)
I/O
Up to 4 channels combining analog, relay or digital outputs and
binary input
Communication
HART 7.2
EMC performance
Emission
EN 55011/CISPR-11 (Class A)
Immunity
EN/IEC 61236-1 (Industry)
Mechanical load
18 to 400 Hz random
The flow meter will mechanically tolerate 3.17 g RMS in all directions.
Flow accuracy cannot be guaranteed under all conditions.
Siemens FI 01 · 2016
3/161
3
© Siemens AG 2016
Flow Measurement
SITRANS F C
Flowmeter SITRANS FC430
Selection and Ordering data
Article No.
SITRANS FC430 Digital coriolis flowmeter
with SITRANS FCS400 Standard flow sensor with hygienic and flange/pipe thread
connections and compact or remote
mounting with FCT030 transmitter
7 ME 4 6 1 3 -
Ord. code
7777 7 - 7 7 7 7 7 7 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
3
Sensor size, connection size
DN 15, DN 10 (½", 3/8")
DN 15, DN 15 (½", ½")
DN 15, DN 20 (½", ¾")
DN 15, DN 25 (½", 1")
3F
 3G
 3H
 3J
DN 25, DN 15 (1", ½")
DN 25, DN 25 (1", 1")
DN 25, DN 40 (1", 1½")
3K
 3L
 3N
DN 50, DN 40 (2", 1½")
DN 50, DN 50 (2", 2")
 4B
 4C
DN 80, DN 65 (3", 2½")
DN 80, DN 80 (3", 3")
DN 80, DN 100 (3", 4")
 4J
 4K
4L
Process connection
EN 1092-1 B1, PN 16
EN 1092-1 B1, PN 40
EN 1092-1 B1, PN 63
EN 1092-1 B1, PN 100
EN 1092-1 B1, PN 160
EN 1092-1 D NUT, PN 40
EN 1092-1 D NUT, PN 63
EN 1092-1 D NUT, PN 100
EN 1092-1 D NUT, PN 160


E1
E3
DIN 11851 hygienic screwed

F1
DIN 32676 hygienic Tri-Clamp

G1
DIN 11864-1A asceptic screwed
DIN 11864-2A asceptic flanged
DIN 11864-3A clamped


H1
H2
H3
ISO 2852 hygienic clamped
ISO 2853 hygienic screwed


J1
J5
3/162
Siemens FI 01 · 2016
A
C
F
H
M
N
P
Q
U


1
3
Order code
Please add "-Z" to Article No. and specify Order
code(s).
Cable glands
Metric, no glands
Metric, plastic
D1
D2
D3
D4
 A01
 A02
Metric, brass/Ni plated
Metric, stainless steel
NPT, no glands
A05
A06
A11
NPT, Plastic
NPT, brass/Ni plated
NPT, stainless steel
A12
A15
A16
Sofware functions and CT approvals
Standard
CT standard
CT with NTEP
 B11
B31
B52
I/O configuration Ch1
Ca 4 ... 20 mA HART active SIL certified
Cp 4 ... 20 mA HART passive SIL certified
Ca 4 ... 20 mA HART active
Cp 4 ... 20 mA HART passive




E04
E05
E06
E07
Options for Ex
ATEX + IECEx + EAC Ex
Only compact versions can be used in SIL applications.
Wetted parts material
Transmitter/DSL material & mounting style
Compact, IP67, aluminum

Remote, IP67, aluminum, M12

Remote, IP67, aluminum, T/Box





Further designs
K1
K5
L2
L4
L6
L7


7 77 7 7 - 7 7 7 7 7 7 7
Selection and Ordering data
A0
A1
A2
A3
B1
A5
A6
A7
A8


Calibration/Accuracy class
0.1 % flow, 5 kg/m³ density
0.1 % flow, 0.5 kg/m³ density
Standard fraction calibration
Ord. code
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
ISO228-1 G pipe thread
ASME B1.20.1 NPT pipe thread
AISI 316L/W1.4435/W1.4404 (100 barg max.) 
Hastelloy C22 (only for 7ME461)
7 ME 4 6 1 3 -
Local User Interface
Blind
Graphical, 240 x 160 pxl

SMS 1145 hygienic screwed
12-VCO-4 quick connect
JIS B2200:2004/10K
JIS B2220:2004/20K
JIS B2220:2004/40K
JIS B2220:2004/63K
Article No.
Ex approval
Non-Ex
ATEX
IECEx
FM
CSA
NEPSI
INMETRO
KCs
EAC
ANSI B16.5-2009, class 150
ANSI B16.5-2009, class 300
ANSI B16.5-2009, class 600
ANSI B16.5-2009, class 900

Selection and Ordering data
SITRANS FC430 Digital coriolis flowmeter
with SITRANS FCS400 Standard flow sensor with hygienic and flange/pipe thread
connections and compact or remote
mounting with FCT030 transmitter
1
3
1
4
8
D
G
K
Q0B
© Siemens AG 2016
Flow Measurement
SITRANS F C
Flowmeter SITRANS FC430
Selection and Ordering data
Order code
I/O configuration Ch2, Ch3 and Ch4
None
Order code
Selection and Ordering data
Add-on options and accessories
 F00
Please add "-Z" to Article No. and specify Order
code(s).
aSignal, None, None
aSignal, aSignal, None
aSignal, aSignal, aSignal
F40
F41
F42
aSignal, aSignal, Ia
aSignal, aSignal, R
aSignal, Ia, None
F43
F44
F45
aSignal, Ia, Ia
aSignal, Ia, R
aSignal, R, None
F46
F47
F50
aSignal, R, R
pSignal, None, None
pSignal, pSignal, None
F51
F60
F61
pSignal, pSignal, pSignal
pSignal, pSignal, Ip
pSignal, pSignal, R
F62
F63
F64
pSignal, Ip, None
pSignal, Ip, Ip
pSignal, Ip, R
F65
F66
F67
pSignal, R, None
pSignal, R, R
aSignal, aSignal, pSignal
F70
F71
F80
aSignal, aSignal, Ip
aSignal, pSignal, None
aSignal, pSignal, pSignal
F81
F82
F83
aSignal, pSignal, Ia
aSignal, pSignal, Ip
aSignal, pSignal, R
F84
F85
F86
Region-specific approvals and certificates
aSignal, Ia, Ip
aSignal, Ip, None
aSignal, Ip, Ip
F87
F90
F91
Additional data
aSignal, Ip, R
pSignal, pSignal, Ia
pSignal, Ia, None
F92
F93
F94
Tag name
pSignal, Ia, Ia
pSignal, Ia, Ip
pSignal, Ia, R
F95
F96
F97
Notes on I/O configurations:
a or p suffix: The I/O module is selected at ordering
with either active or passive function.
Signal: The output can be selected for Current (0 or 4
to 20 mA), frequency or pulse function in the menu.
I: Discrete status input to the flowmeter. Functions are
selected in the menu including 'Freeze output', ’Reset
totalizer'.
R: Relay output for discrete status reporting. Function is
selected in the menu, including 'Error', 'High flow warning'.
The MLFB structure for FC430 systems must be filled to
this level, including "-Z" options A.., B.., E.. and F..
Certificates
Pressure test certificate CRN
Pressure test certificate PED
Material certificate EN 10204-3.1
C01
C02
C05
Welding inspection report
Factory certificate to EN 10204 2.1
Factory certificate to EN 10204 2.2
Cleaning for oil and grease
C07
 C10
C11
C50
3
Cable
None
L50
5 m (16.4 ft), standard with M12 plugs fitted
5 m (16.4 ft), standard
L51
L52
10 m (32.8 ft) standard with M12 plugs fitted
10 m (32.8 ft), standard
L55
L56
25 m (82 ft), standard with M12 plugs fitted
25 m (82 ft), standard
L59
L60
50 m (164 ft), standard with M12 plugs fitted
50 m (164 ft), standard
L63
L64
75 m (246 ft), standard with M12 plugs fitted
75 m (246 ft), standard
L67
L68
150 m (492 ft), standard with M12 plugs fitted
150 m (492 ft), standard
L71
L72
South Korea (KCC)
W28
Please add "-Z" to Article No. and specify Order
code(s) and plain text.
Tag name plate, stainless steel
Y17
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
Operating instructions for SITRANS FC430
Description
Article No.
• English
A5E03361511
• German
A5E03651143
This device is shipped with a Quick Start guide and a CD containing
further SITRANS F C literature.
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
Siemens FI 01 · 2016
3/163
© Siemens AG 2016
Flow Measurement
SITRANS F C
Flowmeter SITRANS FC430
Selection and Ordering data
Article No.
SITRANS FC430 Digital coriolis flowmeter
7 ME 4 6 2 3 -
Ord. code
Further designs
with SITRANS FCS400 Flow sensor
Hygienic version with Ra < 0.8 m, 3A
approved, and compact or remote mounting with FCT030 transmitter
7 77 7 7 - 7 7 7 7 7 7 7
Please add "-Z" to Article No. and specify Order
code(s).
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
3
Sensor size, connection size
DN 15, DN 10 (½", 3/8")
DN 15, DN 15 (½", ½")
DN 15, DN 20 (½", ¾")
DN 15, DN 25 (½", 1")
3F
 3G
 3H
 3J
DN 25, DN 25 (1", 1")
DN 25, DN 32 (1", 1¼")
DN 25, DN 40 (1", 1½")
 3L
3M
 3N
DN 50, DN 40 (2", 1½")
DN 50, DN 50 (2", 2")
 4B
 4C
DN 80, DN 65 (3", 2½")
DN 80, DN 80 (3", 3")
 4J
 4K
Process connection
DIN 11851 0.8 µm hygienic screwed

F1
DIN 32676 0.8 µm hygienic Tri-Clamp

G1
DIN 11864-1 0.8 µm hygienic screwed

DIN 11864-2A BF-A 0.8 µm hygienic
screwed (metric)
DIN 11864-3A BF-A 0.8 µm hygienic

clamped
DIN 11864-2B BF-A 0.8 µm hygienic flanged
(NPS)
H1
H2


J1
J5
ISO 2852 0.8 µm hygienic clamped
ISO 2853 0.8 µm hygienic screwed
Calibration/Accuracy class
0.1 % flow, 5 kg/m³ density
0.1 % flow, 0.5 kg/m³ density
Standard fraction calibration
Transmitter/DSL material and mounting
style
Compact, IP67, aluminum
Remote, IP67, aluminum, M12
Remote, IP67, aluminum, T/Box
Ex approval
Non-Ex
ATEX II 2GD
IECEx GDb
FM, Class 1, Div 1
CSA, Class 1, Zone 1
NEPSI
INMETRO
KCs
EAC
Local User Interface
Blind
Graphical, 240 x 160 pxl











Siemens FI 01 · 2016
 A01
 A02
A05
 A06
A11
A12
A15
A16
Sofware functions and CT approvals
Standard
CT standard
CT with NTEP
 B11
B31
B52
I/O configuration Ch1
Ca 4 ... 20 mA HART active SIL certified
Cp 4 ... 20 mA HART passive SIL certified
Ca 4 ... 20 mA HART active
Cp 4 ... 20 mA HART passive




Only compact versions can be used in SIL applications.
H3
H4
1
1
4
8
D
G
K
A
C
F
H
M
N
P
Q
U
1
3
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
3/164
Cable glands
Metric, no glands
Metric, plastic
Metric, brass/Ni plated
Metric, stainless steel
NPT, no glands
NPT, plastic
NPT, brass/Ni plated
NPT, stainless steel
Options for Ex
ATEX + IECEx + EAC Ex
Wetted parts material
AISI 316L/1.4435 (40 bar max.)
Order code
Selection and Ordering data
E04
E05
E06
E07
Q0B
© Siemens AG 2016
Flow Measurement
SITRANS F C
Flowmeter SITRANS FC430
Selection and Ordering data
Order code
I/O configuration Ch2, Ch3 and Ch4
None
Order code
Selection and Ordering data
Add-on options and accessories
 F00
Please add "-Z" to Article No. and specify Order
code(s).
aSignal, None, None
aSignal, aSignal, None
aSignal, aSignal, aSignal
F40
F41
F42
aSignal, aSignal, Ia
aSignal, aSignal, R
aSignal, Ia, None
F43
F44
F45
aSignal, Ia, Ia
aSignal, Ia, R
aSignal, R, None
F46
F47
F50
aSignal, R, R
pSignal, None, None
pSignal, pSignal, None
F51
F60
F61
pSignal, pSignal, pSignal
pSignal, pSignal, Ip
pSignal, pSignal, R
F62
F63
F64
pSignal, Ip, None
pSignal, Ip, Ip
pSignal, Ip, R
F65
F66
F67
pSignal, R, None
pSignal, R, R
aSignal, aSignal, pSignal
F70
F71
F80
aSignal, aSignal, Ip
aSignal, pSignal, None
aSignal, pSignal, pSignal
F81
F82
F83
aSignal, pSignal, Ia
aSignal, pSignal, Ip
aSignal, pSignal, R
F84
F85
F86
Region-specific approvals and certificates
aSignal, Ia, Ip
aSignal, Ip, None
aSignal, Ip, Ip
F87
F90
F91
Additional data
aSignal, Ip, R
pSignal, pSignal, Ia
pSignal, Ia, None
F92
F93
F94
Tag name
pSignal, Ia, Ia
pSignal, Ia, Ip
pSignal, Ia, R
F95
F96
F97
Notes on I/O configurations:
a or p suffix: The I/O module is selected at ordering
with either active or passive function.
Signal: The output can be selected for Current (0 or 4
to 20 mA), frequency or pulse function in the menu.
I: Discrete status input to the flowmeter. Functions are
selected in the menu including 'Freeze output', ’Reset
totalizer'.
R: Relay output for discrete status reporting. Function is
selected in the menu, including 'Error', 'High flow warning'.
The MLFB structure for FC430 systems must be filled to
this level, including "-Z" options A.., B.., E.. and F..
Certificates
Pressure test certificate CRN
Pressure test certificate PED
Material certificate EN 10204-3.1
C01
C02
C05
Welding inspection report
Factory certificate to EN 10204 2.1
Factory certificate to EN 10204 2.2
Cleaning for oil and grease
C07
 C10
C11
C50
3
Cable
None
5 m (16.4 ft), standard with M12 plugs fitted
5 m (16.4 ft), standard
L50
L51
L52
10 m (32.8 ft) standard with M12 plugs fitted
10 m (32.8 ft), standard
L55
L56
25 m (82 ft), standard with M12 plugs fitted
25 m (82 ft), standard
L59
L60
50 m (164 ft), standard with M12 plugs fitted
50 m (164 ft), standard
L63
L64
75 m (246 ft), standard with M12 plugs fitted
75 m (246 ft), standard
L67
L68
150 m (492 ft), standard with M12 plugs fitted
150 m (492 ft), standard
L71
L72
South Korea (KCC)
W28
Please add "-Z" to Article No. and specify Order
code(s) and plain text.
Tag name plate, stainless steel
Y17
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
Operating instructions for SITRANS FC430
Description
Article No.
• English
A5E03361511
• German
A5E03651143
This device is shipped with a Quick Start guide and a CD containing
further SITRANS F C literature.
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
Siemens FI 01 · 2016
3/165
© Siemens AG 2016
Flow Measurement
SITRANS F C
Flowmeter SITRANS FC430
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS FC430 Digital coriolis flowmeter
7 ME 4 7 1 3 -
Ord. code
SITRANS FC430 Digital coriolis flowmeter
7 ME 4 7 1 3 -
with SITRANS FCS400 NAMUR complient
flow sensor with flange/pipe thread connections and compact or remote mounting with FCT030 transmitter
7 77 7 7 - 7 7 7 7 7 7 7
with SITRANS FCS400 NAMUR complient
flow sensor with flange/pipe thread connections and compact or remote mounting with FCT030 transmitter
7777 7 - 7 7 7 7 7 7 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
3
Sensor size, Connection size
DN 15, DN 6 (½", ¼")
DN 15, DN 10 (½", 3/8")
DN 15, DN 15 (½", ½")
DN 15, DN 20 (½", ¾")
DN 15, DN 25 (½", 1")





DN 25, DN 25 (1", 1")
DN 25, DN 32 (1", 1¼")
DN 25, DN 40 (1", 1½")
 3L
 3M
 3N
DN 50, DN 40 (2", 1½")
DN 50, DN 50 (2", 2")
 4B
 4C
DN 80, DN 65 (3", 2½")
DN 80, DN 80 (3", 3")
DN 80, DN 100 (3", 4")
 4J
 4K
 4L
Process connection
EN 1092-1 B1, PN 16
EN 1092-1 B1, PN 40
EN 1092-1 B1, PN 63
EN 1092-1 B1, PN 100
EN 1092-1 B1, PN 160
Ex approval
Non-Ex
ATEX II 2GD
IECEx GDb
FM, Class 1, Div 1
CSA, Class 1, Zone 1
NEPSI
INMETRO
KCs
EAC
3E
3F
3G
3H
3J
Local User Interface
Blind
Graphical, 240 x 160 pxl


A0
A1
A2
A3
B1


D1
D2
D3
D4
ISO228-1 G pipe thread
ASME B1.20.1 NPT pipe thread


E1
E3
DIN 11851 Hygienic screwed

F1
DIN 32676-C (inch) Hygienic clamped

G1
DIN 11864-1 Hygienic screwed

DIN 11864-2A BF-A Hygienic flanged metric
DIN 11864-3A Hygienic clamped
DIN 11864-2B BF-A Hygienic flanged NPS
H1
H2
H3
H4
ISO 2852 Hygienic clamped
ISO 2853 Hygienic screwed
J1
J5

Order code
Please add "-Z" to Article No. and specify Order
code(s).


Transmitter/DSL material & mounting style
Compact, IP67, aluminum

Remote, IP67, aluminum, M12

Remote, IP67, aluminum, T/Box

 A01
 A02
A05
 A06
A11
A12
A15
A16
Sofware functions and CT approvals
Standard
CT standard
CT with NTEP
 B11
B31
B52
I/O configuration Ch1
Ca 4 ... 20 mA HART active, SIL certified
Cp 4 ... 20 mA HART passive, SIL certified
Ca 4 ... 20 mA HART active
Cp 4 ... 20 mA HART passive




Only compact versions can be used in SIL applications.
K1
K5
Wetted parts material
AISI 316L/W1.4435/W1.4404 (100 barg max.) 
Hastelloy C22
Cable glands
Metric, no glands
Metric, plastic
Metric, brass/Ni plated
Metric, stainless steel
NPT, no glands
NPT, plastic
NPT, brass/Ni plated
NPT, stainless steel
Options for Ex
ATEX + IECEx + EAC Ex
L2
L4
L6
L7
JIS B2200/10K
JIS B2200/20K
JIS B2200/40K
JIS B2200/63K
Siemens FI 01 · 2016
1
3
Further designs
A5
A6
A7
A8

3/166


 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
ANSI B16.5, RF, class 150
ANSI B16.5, RF, class 300
ANSI B16.5, RF, class 600
ANSI B16.5, RF, class 900
Calibration/Accuracy class
0.1 % flow, 5 kg/m³ density
0.1 % flow, 0.5 kg/m³ density
Standard fraction calibration
A
C
F
H
M
N
P
Q
U
Selection and Ordering data
EN 1092-1 D, PN 40
EN 1092-1 D, PN 63
EN 1092-1 D, PN 100
EN 1092-1 D, PN 160
SMS 1145 Hygienic screwed
Swagelok Quick Connect




Ord. code
1
3
1
4
8
D
G
K
E04
E05
E06
E07
Q0B
© Siemens AG 2016
Flow Measurement
SITRANS F C
Flowmeter SITRANS FC430
Selection and Ordering data
Order code
I/O configuration Ch2, Ch3 and Ch4
None
Order code
Selection and Ordering data
Add-on options and accessories
 F00
Please add "-Z" to Article No. and specify Order
code(s).
aSignal, None, None
aSignal, aSignal, None
aSignal, aSignal, aSignal
F40
F41
F42
aSignal, aSignal, Ia
aSignal, aSignal, R
aSignal, Ia, None
F43
F44
F45
aSignal, Ia, Ia
aSignal, Ia, R
aSignal, R, None
F46
F47
F50
aSignal, R, R
pSignal, None, None
pSignal, pSignal, None
F51
F60
F61
pSignal, pSignal, pSignal
pSignal, pSignal, Ip
pSignal, pSignal, R
F62
F63
F64
pSignal, Ip, None
pSignal, Ip, Ip
pSignal, Ip, R
F65
F66
F67
pSignal, R, None
pSignal, R, R
aSignal, aSignal, pSignal
F70
F71
F80
aSignal, aSignal, Ip
aSignal, pSignal, None
aSignal, pSignal, pSignal
F81
F82
F83
aSignal, pSignal, Ia
aSignal, pSignal, Ip
aSignal, pSignal, R
F84
F85
F86
Region-specific approvals and certificates
aSignal, Ia, Ip
aSignal, Ip, None
aSignal, Ip, Ip
F87
F90
F91
Additional data
aSignal, Ip, R
pSignal, pSignal, Ia
pSignal, Ia, None
F92
F93
F94
Tag name
pSignal, Ia, Ia
pSignal, Ia, Ip
pSignal, Ia, R
F95
F96
F97
Notes on I/O configurations:
a or p suffix: The I/O module is selected at ordering
with either active or passive function.
Signal: The output can be selected for Current (0 or 4
to 20 mA), frequency or pulse function in the menu.
I: Discrete status input to the flowmeter. Functions are
selected in the menu including 'Freeze output', ’Reset
totalizer'.
R: Relay output for discrete status reporting. Function is
selected in the menu, including 'Error', 'High flow warning'.
The MLFB structure for FC430 systems must be filled to
this level, including "-Z" options A..., B..., E... and F...
Certificates
Pressure test certificate CRN
Pressure test certificate PED
Material certificate EN 10204-3.1
C01
C02
C05
Welding inspection report
Factory certificate to EN 10204 2.1
Factory certificate to EN 10204 2.2
Cleaning for oil and grease
C07
 C10
C11
C50
3
Cable
None
5 m (16.4 ft), standard with M12 plugs fitted
5 m (16.4 ft), standard
L50
L51
L52
10 m (32.8 ft) standard with M12 plugs fitted
10 m (32.8 ft), standard
L55
L56
25 m (82 ft), standard with M12 plugs fitted
25 m (82 ft), standard
L59
L60
50 m (164 ft), standard with M12 plugs fitted
50 m (164 ft), standard
L63
L64
75 m (246 ft), standard with M12 plugs fitted
75 m (246 ft), standard
L67
L68
150 m (492 ft), standard with M12 plugs fitted
150 m (492 ft), standard
L71
L72
South Korea (KCC)
W28
Please add "-Z" to Article No. and specify Order
code(s) and plain text.
Tag name plate, stainless steel
Y17
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
Operating instructions for SITRANS FC430
Description
Article No.
• English
A5E03361511
• German
A5E03651143
This device is shipped with a Quick Start guide and a CD containing
further SITRANS F C literature.
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
Siemens FI 01 · 2016
3/167
© Siemens AG 2016
Flow Measurement
SITRANS F C
Flowmeter - Accessories/Spare parts
Accessories
Description
Article No.
Description
CT plug
Tamper cover for CT locking. Fits over the M12 plug
at both sensor and transmitter ends of the remote system cable (2 pcs.)
A5E31478498
Standard cable (Ex) with
M12 plugs, PO insulation
and PUR sleeve, blue,
-40 ... +80 °C
(-40 ... +176 °F)
Bag of glands (metric) in
black plastic1)
A5E03907414
Bag of glands, (metric) in
gray plastic Ex e/i1)
A5E03907424
Bag of glands (metric) in
AISI 316 SS Ex e/i1)
A5E03907429
Bag of glands (metric) in
Ni-plated brass Ex e/i1)
A5E03907430
Bag of glands (NPT) in
black plastic2)
Bag of glands (NPT) in gray
plastic Ex e/i2)
Article No.
•5m
A5E03914929
• 10 m
A5E03914962
• 25 m
A5E03914995
• 50 m
A5E03915004
• 75 m
A5E03915074
• 150 m
A5E03915088
3
Standard cable (Ex) for termination, PO insulation and
PUR sleeve, blue,
-40 ... +80 °C
(-40 ... +176 °F)
A5E03907435
A5E03907451
Bag of glands (NPT) in
AISI 316 SS Ex e/i2)
A5E03907467
Bag of glands (NPT) in
Ni-plated brass Ex e/i2)
A5E03907473
Standard cable (non-Ex)
with M12 plugs, PO insulation and PUR sleeve, gray,
-40 ... +80 °C
(-40 ... +176 °F)
• 5 m (16.4 ft)
A5E03914805
• 10 m (32.8 ft)
A5E03914850
• 25 m (82 ft)
A5E03914853
• 50 m (164 ft)
A5E03914859
• 75 m (246 ft)
A5E03914861
• 150 m (492 ft)
A5E03914874
•5m
A5E03914945
• 10 m
A5E03914973
• 25 m
A5E03914984
• 50 m
A5E03915015
• 75 m
A5E03915057
• 150 m
A5E03915100
Suitcase for comprehensive sales support and
training for FC430
It comes in a special suitcase with a fan implemented that allows the
flowmeter to demonstrate
airflow.
A5E31467598
Suitcase for comprehensive sales support and
training for FC410.
It comes in a special suitcase with an S7-1200 PLC
and HMI touch-screen display. The operating code is
open-source and can be
copied to customers to
assist with system integration.
A5E33219071
Service toolkit for field maintenance of transmitter and
sensor components. Contains all hand tools necessary for maintenance. Other
tools may be required for
installation.
A5E03722877
Standard cable (non-Ex) for
termination, PO insulation
and PUR sleeve, gray,
-40 ... +80 °C
(-40 ... +176 °F)
• 5 m (16.4 ft)
A5E03914833
• 10 m (32.8 ft)
A5E03914849
• 25 m (82 ft)
A5E03914854
• 50 m (164 ft)
A5E03914856
• 75 m (246 ft)
A5E03914864
• 150 m (492 ft)
A5E03914873
Siemens FI 01 · 2016
3/179
© Siemens AG 2016
Flow Measurement
SITRANS F C
Flowmeter - Accessories/Spare parts
Article No.
Description
Heating Jacket, indoor use,
0 ... 200 °C (32 ... 392 °F)
max. temperature. Complete
with 5 m (16.4 ft) high temperature cable fitted. Dedicated plug connection to
included controller
Description
Dimension
Article No.
DN 10
FDK:085U1016
DN 15
FDK:085U1017
DN 25
FDK:085U1019
DN 32
FDK:085U1020
DN 40
FDK:085U1021
DN 50
FDK:085U1022
DN 65
FDK:085U1023
25 mm
FDK:085U1029
40 mm
FDK:085U1031
50 mm
FDK:085U1032
DN 10
FDK:085U1006
DN 15
FDK:085U1007
DN 25
FDK:085U1009
DN 32
FDK:085U1010
DN 40
FDK:085U1011
DN 50
FDK:085U1012
DN 65
FDK:085U1013
Mating parts for hygienic fittings
DIN 11851
Includes:
• 2 unions
• 2 mating parts (for welding in)
• 2 EPDM gaskets
• 230 V AC
3
- DN 15 electric
A5E33035287
- DN 25 electric
A5E33035324
- DN 50 electric
A5E33035325
- DN 80 electric
A5E33035336
• 115 V AC
- DN 15 electric
A5E32877520
- DN 25 electric
A5E32877556
- DN 50 electric
A5E32877557
- DN 80 electric
A5E32877561
Heating jacket controller,
IP65. Digital display for
0 ... 200 °C (32 .. 392 °F)
control setpoint
• 230 V AC
A5E03839193
• 115 V AC
A5E03839194
1)
2 pcs M20; 1 pce M25 with single and dual cable inserts
2)
2 pcs ½" NPT; 1 pce ½" NPT with single and dual cable inserts
Mating parts for hygienic clamp
ISO 2852
Includes:
• 2 clamps
• 2 mating parts
• 2 EPDM gaskets
2 EPDM gaskets with collar for
mounting set DIN 11851
3/180
Siemens FI 01 · 2016
© Siemens AG 2016
Flow Measurement
SITRANS F C
Flowmeter - Accessories/Spare parts
Spare parts - transmitter FCT030
Article No.
Description
Article No.
Display and keypad assembly with firewire connection
to the transmitter module1)
A5E03548971
Mounting bracket - FCT030;
in painted aluminum for
pipe or wall mounting of
transmitter FCT030 remote
version. Including lock ring,
pressure pads and seal cap
A5E03906091
Sensor interface (Compact).
Front end flow calculator and
process detection. SIL 3
approved1)
A5E03549142
M12 option for sensor housing in stainless steel. Prewired and potted to replace
M12 socket in DSL housing
A5E03906095
A5E03549098
M12 option - remote - in
painted aluminum. Prewired and potted replacement M12 connection for
FCT030 transmitter remote
version
A5E03906104
Sensor interface (Remote);
barrier unit for high speed
digital communication and
Ex ib power supply to
remote front end
DSL module
Remote terminal house M20
A5E03906112
Display lid in painted aluminum with Ex glass plate and
o-ring seal
A5E03549344
Remote terminal house NPT - in painted aluminum
for sensor cable termination
at FCT030 transmitter
remote version. Pre-wired
and potted
A5E03906130
Transmitter cassette (active)
with SIL approved
4 ... 20 mA output and
HART 7.21)
A5E03549357
Transmitter cassette (passive) with SIL approved
4 ... 20 mA output and
HART 7.21)
A5E03549383
Bag of loose spare parts;
including cable strain relief
components, mounting tool,
seals and gasket, assorted
screws and washers, hex
cap nut, blind plugs, and
o-rings
A5E03549396
Power supply
240 V AC, 47 ... 63 Hz
24 ... 90 V DC
A5E03549413
Blind lid in painted aluminum with o-ring seal
A5E03549429
Description
3
Spare parts - sensor FCS400
I/O assembly
Advise Order code
F00 to F97 from Selection
and Ordering data2)
A5E03939114
SensorFlash
(micro SD card)
A5E03915258
Description
Article No.
Blind lid in painted aluminum with o-ring seal
A5E03549295
Frontend cassette
Spare part frontend
cassette for remote version
of FC430 and cassette for
FC4101)
A5E03549191
Sensor housing metric
A5E03549313
Sensor housing NPT in
painted aluminum
A5E03906080
Bag of loose parts for sensor; including cable strain
relief components, washer,
seals, o-rings, and assorted
screws
A5E03549324
1)
The system firmware bundle must be stated in the "Remark" field when
ordering, to ensure compatibility of the system. The FW revision is found
on the product label for FC430 and FC410.
Further for FC430 the firmware bundle can be found in the local display in
the menu items 3.1.10. e.g. "2.02.01-02"
2)
The I/O configuration must be stated in the "Remark" field. The I/O configuration is found in the F option of the ordering code. e.g. code “F40” for
ordering Ch2 Active Current/Freq/Pulse, Ch3 Active Current/Freq/Pulse,
Ch4 Active Input
Siemens FI 01 · 2016
3/181