© Siemens AG 2016 Flow Measurement SITRANS F C Flowmeter SITRANS FC410 ■ Overview ■ Technical specifications 3 Sizes DN 15 (½"), DN 25 (1"), DN 50 (2"), DN 80 (3") Accuracy ± 0.10 % Repeatability ± 0.05 % Flow range (water @ 1 bar pressure loss) DN 15: 3 700 kg/h (8 157 lb/h) DN 25: 11 500 kg/h (25 353 lb/h) DN 50: 52 000 kg/h (114 640 lb/h) DN 80: 136 000 kg/h (300 000 lb/h) Power supply 24 V DC ± 20 %; 110 mA Weight 4.6 ... 50 kg Material • Sensor - Measuring tubes - Enclosure The compact flowmeter SITRANS FC410 can be ordered for industrial, hygienic or NAMUR service. Intended for integration into OEM skids, machines or pre-assembled plant systems, the flowmeter is based on the latest developments within digital signal processing technology - engineered for high measuring performance: • Fast response to rapid changes in flow • Fast dosing applications with control in host system • High immunity against process noise • High turndown ratio of flowrates • Suitable for liquid and gas service • Easy to install, commission and maintain With all global marine approvals the FC410 is ideal for integration in ship fuel efficiency and environmental measurement systems as well as bunkerings solutions. 316L stainless steel or Hastelloy C22 304 stainless steel • Transmitter Aluminum with corrosion-resistant coating Enclosure rating IP67 Pressure ratings • Measuring tubes - 316L 100 bar (1450 psi) - Hastelloy C22 160 bar (2321 psi) • Sensor enclosure 20 bar (DN15, DN 25) 17 bar (DN 50, DN 80) • Sensor enclosure burst pressure >160 bar (all sizes) Temperature ratings • Process medium -50 ... +200 °C (-58 ... +392 °F) • Ambient -40 ... +60 °C (-40 ... +140 °F) Process connections • Flanges The FCT010 transmitter delivers true multi-parameter measurements i.e. massflow, density, temperature EN 1092-1 B1, EN 1092-1 D, ANSI/ASME B16.5, JIS B 2220, DIN 11864-2 • Pipe threads FC410 is available with Modbus RTU (RS 485) multi-drop serial communication. ASME B1.20 (NPT), ISO228-1 G (BSPP), VCO Quick-connect • Hygienic threads The flowmeter is supplied with SensorFlash, a micro SD card containing all relevant certificates. DIN 11851, DIN 11864-1A, ISO 2853, SMS 1145 • Hygienic clamps DIN 11864-3A, DIN 32676, ISO 2852 The SITRANS FC410 flowmeter system consists of a SITRANS FCS400 sensor and a SITRANS FCT010 transmitter always compact mounted. ■ Benefits • It is compact and light, fitting neatly into dense piping arrangements • Effective separation of measurement from plant vibration • Reliable measurements due to high signal to noise ratio • Short overall length; easy drop-in replacement into most existing installations • Direct connection to host with high-speed Modbus simplifies machine or skid construction and set-up. • Modbus RS485 RTU allows simple and easy integration with all Modbus masters with fast update rate of process values 3/168 Siemens FI 01 · 2016 Approvals • Hazardous area ATEX, IECEx, EAC Ex, FM, NEPSI, CSA, INMETRO (installed with flameproof conduit) • Pressure equipment PED, CRN • Hygienic 3A, EHEDG • Marine Germanischer Lloyd/det Norske Veritas, Bureau Veritas, Lloyds of London, American Bureau of Shipping NAMUR NAMUR-compliant (e.g. NE 21, NE 41 and NE 132) Communication Modbus RS 485 RTU EMC performance Emission EN 55011/CISPR-11 (Class B) Immunity EN/IEC 61236-1 (Industry) Mechanical load 18 to 400 Hz random The flow meter will mechanically tolerate 3.17 g RMS in all directions. Flow accuracy cannot be guaranteed under all conditions. © Siemens AG 2016 Flow Measurement SITRANS F C Flowmeter SITRANS FC410 Selection and Ordering data Article No. SITRANS FC410 Digital coriolis flowmeter with SITRANS FCS400 Standard flow sensor with hygienic and flange/pipe thread connections and compact mounting with FCT010 transmitter 7 ME 4 6 1 1 7777 7 - 7 D 7 1 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Sensor size, connection size DN 15, DN 10 (½", 3/8") DN 15, DN 15 (½", ½") DN 15, DN 20 (½", ¾") DN 15, DN 25 (½", 1") 3F 3G 3H 3J DN 25, DN 15 (1", ½") DN 25, DN 25 (1", 1") DN 25, DN 40 (1", 1½") 3K 3L 3N DN 50, DN 40 (2", 1½") DN 50, DN 50 (2", 2") 4B 4C DN 80, DN 65 (3", 2½") DN 80, DN 80 (3", 3") DN 80, DN 100 (3", 4") 4J 4K 4L Process connection EN 1092-1 B1, PN 16 EN 1092-1 B1, PN 40 EN 1092-1 B1, PN 63 EN 1092-1 B1, PN 100 EN 1092-1 B1, PN 160 EN 1092-1 D NUT, PN 40 EN 1092-1 D NUT, PN 63 EN 1092-1 D NUT, PN 100 EN 1092-1 D NUT, PN 160 Article No. 7 ME 4 6 1 1 - Ord. code 7 77 7 7 - 7 D 7 1 777 A C F H M N P Q U 3 Order code Selection and Ordering data Further designs Please add "-Z" to Article No. and specify Order code(s). Cable glands Metric, no glands Metric, plastic A0 A1 A2 A3 B1 A5 A6 A7 A8 ISO228-1 G pipe thread ASME B1.20.1 NPT pipe thread E1 E3 DIN 11851 hygienic screwed F1 777 Selection and Ordering data SITRANS FC410 Digital coriolis flowmeter with SITRANS FCS400 Standard flow sensor with hygienic and flange/pipe thread connections and compact mounting with FCT010 transmitter Ex approval Non-Ex ATEX II 2GD IECEx GDb FM, Class 1, Div 1 CSA, Class 1, Zone 1 NEPSI INMETRO KCs EAC ANSI B16.5-2009, class 150 ANSI B16.5-2009, class 300 ANSI B16.5-2009, class 600 ANSI B16.5-2009, class 900 D1 D2 D3 D4 DIN 32676 hygienic Tri-Clamp G1 DIN 11864-1A asceptic screwed DIN 11864-2A asceptic flanged DIN 11864-3A clamped H1 H2 H3 ISO 2852 hygienic clamped ISO 2853 hygienic screwed J1 J5 A01 A02 Metric, brass/Ni plated Metric, stainless steel NPT, no glands A05 A06 A11 NPT, Plastic NPT, brass/Ni plated NPT, stainless steel A12 A15 A16 Integral M12 socket A20 Sofware functions and CT approvals Standard B11 I/O configuration Ch1 Modbus RTU RS 485 E14 I/O configuration Ch2, Ch3 and Ch4 F00 None Options for Ex ATEX + IECEx + EAC Ex Q0B The Article No. for FC410 systems must be filled to this level, including "-Z" options A.., B.., E.. and F.. We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. K1 K5 L2 L4 L6 L7 SMS 1145 hygienic screwed 12-VCO-4 quick connect JIS B2200:2004/10K JIS B2220:2004/20K JIS B2220:2004/40K JIS B2220:2004/63K Wetted parts material AISI 316L/W1.4435/W1.4404 (100 barg max.) Hastelloy C22 (only for 7ME461) Calibration/Accuracy class 0.1 % flow, 5 kg/m³ density 0.1 % flow, 0.5 kg/m³ density Ord. code 1 3 1 4 Siemens FI 01 · 2016 3/169 © Siemens AG 2016 Flow Measurement SITRANS F C Flowmeter SITRANS FC410 Order code Selection and Ordering data Add-on options and accessories Please add "-Z" to Article No. and specify Order code(s). Certificates Pressure test certificate CRN Pressure test certificate PED Material certificate EN 10204-3.1 3 C01 C02 C05 Welding inspection report Factory certificate to EN 10204 2.1 Factory certificate to EN 10204 2.2 Cleaned for oil and grease C07 C10 C11 C50 Cable1) None L50 5 m (16.4 ft), standard with M12 plugs fitted 5 m (16.4 ft), standard L51 L52 10 m (32.8 ft) standard with M12 plugs fitted 10 m (32.8 ft), standard L55 L56 25 m (82 ft), standard with M12 plugs fitted 25 m (82 ft), standard L59 L60 50 m (164 ft), standard with M12 plugs fitted 50 m (164 ft), standard L63 L64 75 m (246 ft), standard with M12 plugs fitted 75 m (246 ft), standard L67 L68 150 m (492 ft), standard with M12 plugs fitted 150 m (492 ft), standard L71 L72 Additional data Please add "-Z" to Article No. and specify Order code(s) and plain text. Tag name Tag name plate, stainless steel 1) Y17 M12 versions of cable have a plug at both ends. We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Operating instructions for SITRANS FC410 Description Article No. • English A5E33120874 • German A5E33124885 This device is shipped with a Quick Start guide and a CD containing further SITRANS F C literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation 3/170 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F C Flowmeter SITRANS FC410 Selection and Ordering data Article No. SITRANS FC410 Digital coriolis flowmeter 7 ME 4 6 2 1 - Ord. code with SITRANS FCS400 Flow sensor Hygienic version with Ra < 0.8 m, 3A approved, and compact mounting with FCT010 transmitter 7 77 7 7 - 7 D 7 1 Order code Selection and Ordering data Further designs 777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Please add "-Z" to Article No. and specify Order code(s). Cable glands Metric, no glands Metric, plastic Metric, brass/Ni plated Metric, stainless steel NPT, no glands NPT, plastic NPT, brass/Ni plated NPT, stainless steel Integral M12 socket A01 A02 A05 A06 A11 A12 A15 A16 A20 Sofware functions and CT approvals Standard B11 E14 Sensor size, connection size DN 15, DN 10 (½", 3/8") DN 15, DN 15 (½", ½") DN 15, DN 20 (½", ¾") DN 15, DN 25 (½", 1") 3F 3G 3H 3J DN 25, DN 25 (1", 1") DN 25, DN 32 (1", 1¼") DN 25, DN 40 (1", 1½") 3L 3M 3N DN 50, DN 40 (2", 1½") DN 50, DN 50 (2", 2") 4B 4C I/O configuration Ch1 Modbus RTU RS 485 DN 80, DN 65 (3", 2½") DN 80, DN 80 (3", 3") 4J 4K I/O configuration Ch2, Ch3 and Ch4 F00 None Process connection Options for Ex DIN 11851 0.8 µm hygienic screwed F1 ATEX + IECEx + EAC Ex DIN 32676 0.8 µm hygienic Tri-Clamp G1 DIN 11864-1 0.8 µm hygienic screwed DIN 11864-2A BF-A 0.8 µm hygienic flanged (metric) DIN 11864-3A BF-A0.8 µm hygienic clamped DIN 11864-2B BF-A0.8 µm hygienic flanged (NPS) H1 H2 The Article No. for FC410 systems must be filled to this level, including "-Z" options A.., B.., E.. and F.. J1 J5 ISO 2852 0.8 µm hygienic clamped ISO 2853 0.8 µm hygienic screwed 3 Q0B We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. H3 H4 Wetted parts material AISI 316L/1.4435 (40 bar max.) Calibration/Accuracy class 0.1 % flow, 5 kg/m³ density 0.1 % flow, 0.5 kg/m³ density Standard fraction calibration Ex approval Non-Ex ATEX II 2GD IECEx GDb FM, Class 1, Div 1 CSA, Class 1, Zone 1 NEPSI INMETRO KCs EAC 1 1 4 8 A C F H M N P Q U We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Siemens FI 01 · 2016 3/171 © Siemens AG 2016 Flow Measurement SITRANS F C Flowmeter SITRANS FC410 Order code Selection and Ordering data Add-on options and accessories Please add "-Z" to Article No. and specify Order code(s). Certificates Pressure test certificate CRN Pressure test certificate PED Material certificate EN 10204-3.1 3 C01 C02 C05 Welding inspection report Factory certificate to EN 10204 2.1 Factory certificate to EN 10204 2.2 Cleaned for oil and grease C07 C10 C11 C50 Cable1) None 5 m (16.4 ft), standard with M12 plugs fitted 5 m (16.4 ft), standard L50 L51 L52 10 m (32.8 ft) standard with M12 plugs fitted 10 m (32.8 ft), standard L55 L56 25 m (82 ft), standard with M12 plugs fitted 25 m (82 ft), standard L59 L60 50 m (164 ft), standard with M12 plugs fitted 50 m (164 ft), standard L63 L64 75 m (246 ft), standard with M12 plugs fitted 75 m (246 ft), standard L67 L68 150 m (492 ft), standard with M12 plugs fitted 150 m (492 ft), standard L71 L72 Additional data Please add "-Z" to Article No. and specify Order code(s) and plain text. Tag name Tag name plate, stainless steel 1) Y17 M12 versions of cable have a plug at both ends. We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Operating instructions for SITRANS FC410 Description Article No. • English A5E33120874 • German A5E33124885 This device is shipped with a Quick Start guide and a CD containing further SITRANS F C literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation 3/172 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F C Flowmeter SITRANS FC410 Selection and Ordering data Article No. SITRANS FC410 Digital coriolis flowmeter with SITRANS FCS400 NAMUR complient flow sensor with flange/pipe thread connections and compact mounting with FCT010 transmitter 7 ME 4 7 1 1 7 77 7 7 - 7 D 7 1 Sensor size, Connection size DN 15, DN 6 (½", ¼") DN 15, DN 10 (½", 3/8") DN 15, DN 15 (½", ½") DN 15, DN 20 (½", ¾") DN 15, DN 25 (½", 1") DN 25, DN 25 (1", 1") DN 25, DN 32 (1", 1¼") DN 25, DN 40 (1", 1½") 3L 3M 3N DN 50, DN 40 (2", 1½") DN 50, DN 50 (2", 2") 4B 4C DN 80, DN 65 (3", 2½") DN 80, DN 80 (3", 3") DN 80, DN 100 (3", 4") 4J 4K 4L ANSI B16.5, RF, class 150 ANSI B16.5, RF, class 300 ANSI B16.5, RF, class 600 ANSI B16.5, RF, class 900 ISO228-1 G pipe thread ASME B1.20.1 NPT pipe thread 3E 3F 3G 3H 3J Article No. 7 ME 4 7 1 1 - 3 Order code Further designs Please add "-Z" to Article No. and specify Order code(s). A0 A1 A2 A3 B1 D1 D2 D3 D4 E1 E3 Cable glands Metric, no glands Metric, plastic Metric, brass/Ni plated Metric, stainless steel NPT, no glands NPT, plastic NPT, brass/Ni plated NPT, stainless steel A01 A02 A05 A06 A11 A12 A15 A16 Sofware functions and CT approvals Standard B11 I/O configuration Ch1 Modbus RTU RS 485 E14 F1 DIN 32676-C (inch) Hygienic clamped G1 None DIN 11864-1 Hygienic screwed DIN 11864-2A BF-A Hygienic flanged metric DIN 11864-3A Hygienic clamped DIN 11864-2B BF-A Hygienic flanged NPS H1 H2 H3 H4 Options for Ex ISO 2852 Hygienic clamped ISO 2853 Hygienic screwed J1 J5 F00 ATEX + IECEx + EAC Ex Q0B The Article No. structure for FC410 systems must be filled to this level, including "-Z" options A..., B..., E... and F... We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. K1 K5 L2 L4 L6 L7 JIS B2200/10K JIS B2200/20K JIS B2200/40K JIS B2200/63K Wetted parts material AISI 316L/W1.4435/W1.4404 (100 barg max.) Hastelloy C22 Calibration/Accuracy class 0.1 % flow, 5 kg/m³ density 0.1 % flow, 0.5 kg/m³ density Standard fraction calibration 777 A C F H M N P Q U Selection and Ordering data DIN 11851 Hygienic screwed 7777 7 - 7 D 7 1 I/O configuration Ch2, Ch3 and Ch4 SMS 1145 Hygienic screwed Swagelok Quick Connect Ord. code We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. A5 A6 A7 A8 EN1092-1 D, PN 40 EN1092-1 D, PN 63 EN1092-1 D, PN 100 EN1092-1 D, PN 160 777 Selection and Ordering data SITRANS FC410 Digital coriolis flowmeter with SITRANS FCS400 NAMUR complient flow sensor with flange/pipe thread connections and compact mounting with FCT010 transmitter Ex approval Non-Ex ATEX II 2GD IECEx GDb FM, Class 1, Div 1 CSA, Class 1, Zone 1 NEPSI INMETRO KCs EAC Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Process connection EN1092-1 B1, PN 16 EN1092-1 B1, PN 40 EN1092-1 B1, PN 63 EN1092-1 B1, PN 100 EN1092-1 B1, PN 160 Ord. code 1 3 1 4 8 Siemens FI 01 · 2016 3/173 © Siemens AG 2016 Flow Measurement SITRANS F C Flowmeter SITRANS FC410 Selection and Ordering data Order code Order code Selection and Ordering data Add-on options and accessories Tag name Please add "-Z" to Article No. and specify Order code(s). Tag name plate, stainless steel 1) Y17 M12 versions of cable have a plug at both ends. Certificates Pressure test certificate CRN Pressure test certificate PED Material certificate EN 10204-3.1 3 Welding inspection report Factory certificate to EN 10204 2.1 Factory certificate to EN 10204 2.2 Cleaned for oil and grease C01 C02 C05 C07 C10 C11 C50 Operating instructions for SITRANS FC410 Description Article No. • English A5E33120874 • German A5E33124885 This device is shipped with a Quick Start guide and a CD containing further SITRANS F C literature. Cable1) None 5 m (16.4 ft), standard with M12 plugs fitted 5 m (16.4 ft), standard L50 L51 L52 10 m (32.8 ft) standard with M12 plugs fitted 10 m (32.8 ft), standard L55 L56 25 m (82 ft), standard with M12 plugs fitted 25 m (82 ft), standard L59 L60 50 m (164 ft), standard with M12 plugs fitted 50 m (164 ft), standard L63 L64 75 m (246 ft), standard with M12 plugs fitted 75 m (246 ft), standard L67 L68 150 m (492 ft), standard with M12 plugs fitted 150 m (492 ft), standard L71 L72 Additional data Please add "-Z" to Article No. and specify Order code(s) and plain text. 3/174 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Siemens FI 01 · 2016 All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation © Siemens AG 2016 Flow Measurement SITRANS F C Flowmeter - Accessories/Spare parts Accessories Description Article No. Description CT plug Tamper cover for CT locking. Fits over the M12 plug at both sensor and transmitter ends of the remote system cable (2 pcs.) A5E31478498 Standard cable (Ex) with M12 plugs, PO insulation and PUR sleeve, blue, -40 ... +80 °C (-40 ... +176 °F) Bag of glands (metric) in black plastic1) A5E03907414 Bag of glands, (metric) in gray plastic Ex e/i1) A5E03907424 Bag of glands (metric) in AISI 316 SS Ex e/i1) A5E03907429 Bag of glands (metric) in Ni-plated brass Ex e/i1) A5E03907430 Bag of glands (NPT) in black plastic2) Bag of glands (NPT) in gray plastic Ex e/i2) Article No. •5m A5E03914929 • 10 m A5E03914962 • 25 m A5E03914995 • 50 m A5E03915004 • 75 m A5E03915074 • 150 m A5E03915088 3 Standard cable (Ex) for termination, PO insulation and PUR sleeve, blue, -40 ... +80 °C (-40 ... +176 °F) A5E03907435 A5E03907451 Bag of glands (NPT) in AISI 316 SS Ex e/i2) A5E03907467 Bag of glands (NPT) in Ni-plated brass Ex e/i2) A5E03907473 Standard cable (non-Ex) with M12 plugs, PO insulation and PUR sleeve, gray, -40 ... +80 °C (-40 ... +176 °F) • 5 m (16.4 ft) A5E03914805 • 10 m (32.8 ft) A5E03914850 • 25 m (82 ft) A5E03914853 • 50 m (164 ft) A5E03914859 • 75 m (246 ft) A5E03914861 • 150 m (492 ft) A5E03914874 •5m A5E03914945 • 10 m A5E03914973 • 25 m A5E03914984 • 50 m A5E03915015 • 75 m A5E03915057 • 150 m A5E03915100 Suitcase for comprehensive sales support and training for FC430 It comes in a special suitcase with a fan implemented that allows the flowmeter to demonstrate airflow. A5E31467598 Suitcase for comprehensive sales support and training for FC410. It comes in a special suitcase with an S7-1200 PLC and HMI touch-screen display. The operating code is open-source and can be copied to customers to assist with system integration. A5E33219071 Service toolkit for field maintenance of transmitter and sensor components. Contains all hand tools necessary for maintenance. Other tools may be required for installation. A5E03722877 Standard cable (non-Ex) for termination, PO insulation and PUR sleeve, gray, -40 ... +80 °C (-40 ... +176 °F) • 5 m (16.4 ft) A5E03914833 • 10 m (32.8 ft) A5E03914849 • 25 m (82 ft) A5E03914854 • 50 m (164 ft) A5E03914856 • 75 m (246 ft) A5E03914864 • 150 m (492 ft) A5E03914873 Siemens FI 01 · 2016 3/179 © Siemens AG 2016 Flow Measurement SITRANS F C Flowmeter - Accessories/Spare parts Article No. Description Heating Jacket, indoor use, 0 ... 200 °C (32 ... 392 °F) max. temperature. Complete with 5 m (16.4 ft) high temperature cable fitted. Dedicated plug connection to included controller Description Dimension Article No. DN 10 FDK:085U1016 DN 15 FDK:085U1017 DN 25 FDK:085U1019 DN 32 FDK:085U1020 DN 40 FDK:085U1021 DN 50 FDK:085U1022 DN 65 FDK:085U1023 25 mm FDK:085U1029 40 mm FDK:085U1031 50 mm FDK:085U1032 DN 10 FDK:085U1006 DN 15 FDK:085U1007 DN 25 FDK:085U1009 DN 32 FDK:085U1010 DN 40 FDK:085U1011 DN 50 FDK:085U1012 DN 65 FDK:085U1013 Mating parts for hygienic fittings DIN 11851 Includes: • 2 unions • 2 mating parts (for welding in) • 2 EPDM gaskets • 230 V AC 3 - DN 15 electric A5E33035287 - DN 25 electric A5E33035324 - DN 50 electric A5E33035325 - DN 80 electric A5E33035336 • 115 V AC - DN 15 electric A5E32877520 - DN 25 electric A5E32877556 - DN 50 electric A5E32877557 - DN 80 electric A5E32877561 Heating jacket controller, IP65. Digital display for 0 ... 200 °C (32 .. 392 °F) control setpoint • 230 V AC A5E03839193 • 115 V AC A5E03839194 1) 2 pcs M20; 1 pce M25 with single and dual cable inserts 2) 2 pcs ½" NPT; 1 pce ½" NPT with single and dual cable inserts Mating parts for hygienic clamp ISO 2852 Includes: • 2 clamps • 2 mating parts • 2 EPDM gaskets 2 EPDM gaskets with collar for mounting set DIN 11851 3/180 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F C Flowmeter - Accessories/Spare parts Spare parts - transmitter FCT030 Article No. Description Article No. Display and keypad assembly with firewire connection to the transmitter module1) A5E03548971 Mounting bracket - FCT030; in painted aluminum for pipe or wall mounting of transmitter FCT030 remote version. Including lock ring, pressure pads and seal cap A5E03906091 Sensor interface (Compact). Front end flow calculator and process detection. SIL 3 approved1) A5E03549142 M12 option for sensor housing in stainless steel. Prewired and potted to replace M12 socket in DSL housing A5E03906095 A5E03549098 M12 option - remote - in painted aluminum. Prewired and potted replacement M12 connection for FCT030 transmitter remote version A5E03906104 Sensor interface (Remote); barrier unit for high speed digital communication and Ex ib power supply to remote front end DSL module Remote terminal house M20 A5E03906112 Display lid in painted aluminum with Ex glass plate and o-ring seal A5E03549344 Remote terminal house NPT - in painted aluminum for sensor cable termination at FCT030 transmitter remote version. Pre-wired and potted A5E03906130 Transmitter cassette (active) with SIL approved 4 ... 20 mA output and HART 7.21) A5E03549357 Transmitter cassette (passive) with SIL approved 4 ... 20 mA output and HART 7.21) A5E03549383 Bag of loose spare parts; including cable strain relief components, mounting tool, seals and gasket, assorted screws and washers, hex cap nut, blind plugs, and o-rings A5E03549396 Power supply 240 V AC, 47 ... 63 Hz 24 ... 90 V DC A5E03549413 Blind lid in painted aluminum with o-ring seal A5E03549429 Description 3 Spare parts - sensor FCS400 I/O assembly Advise Order code F00 to F97 from Selection and Ordering data2) A5E03939114 SensorFlash (micro SD card) A5E03915258 Description Article No. Blind lid in painted aluminum with o-ring seal A5E03549295 Frontend cassette Spare part frontend cassette for remote version of FC430 and cassette for FC4101) A5E03549191 Sensor housing metric A5E03549313 Sensor housing NPT in painted aluminum A5E03906080 Bag of loose parts for sensor; including cable strain relief components, washer, seals, o-rings, and assorted screws A5E03549324 1) The system firmware bundle must be stated in the "Remark" field when ordering, to ensure compatibility of the system. The FW revision is found on the product label for FC430 and FC410. Further for FC430 the firmware bundle can be found in the local display in the menu items 3.1.10. e.g. "2.02.01-02" 2) The I/O configuration must be stated in the "Remark" field. The I/O configuration is found in the F option of the ordering code. e.g. code “F40” for ordering Ch2 Active Current/Freq/Pulse, Ch3 Active Current/Freq/Pulse, Ch4 Active Input Siemens FI 01 · 2016 3/181