US1JDF/US1MDF Green 1.0A SURFACE MOUNT ULTRA-FAST RECTIFIER Product Summary (@ TA = +25°C) Features and Benefits VRRM (V) IO (A) VF Max (V) IR Max (µA) Glass Passivated Die Construction 600,1000 1 1.7 5 Ultra-Fast Recovery Time for High Efficiency Surge Overload Rating to 30A Peak High Current Capability Low Profile Design, Package Height Less than 1.1mm Lead-Free Finish; RoHS Compliant (Notes 1 & 2) Halogen and Antimony Free. “Green” Device (Note 3) Description The US1JDF and US1MDF are rectifiers packaged in the low profile D-FLAT package. Providing ultra-fast recovery time for high efficiency, this device is ideal for use in general rectification applications. Applications Mechanical Data Switching Mode Power Supply DC-DC Converter Case: D-FLAT Case Material: Molded Plastic, “Green” Molding Compound. UL Flammability Classification Rating 94V-0 Moisture Sensitivity: Level 1 per J-STD-020 Terminals: Finish - Matte Tin Annealed over Copper Leadframe. Solderable per MIL-STD-202, Method 208 Polarity: Cathode Band Weight: 0.035 grams (Approximate) D-FLAT Top View Ordering Information (Note 4) Part Number US1JDF-13 US1MDF-13 Notes: Qualification Commercial Commercial Case D-FLAT D-FLAT Packaging 10,000/Tape & Reel 10,000/Tape & Reel 1. EU Directive 2002/95/EC (RoHS) & 2011/65/EU (RoHS 2) compliant. All applicable RoHS exemptions applied. 2. See http://www.diodes.com/quality/lead_free.html for more information about Diodes Incorporated’s definitions of Halogen- and Antimony-free, "Green" and Lead-free. 3. Halogen- and Antimony-free "Green” products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and <1000ppm antimony compounds. 4. For packaging details, go to our website at http://www.diodes.com/products/packages.html. Marking Information U1J or U1M = Product Type Marking Code = Manufacturers’ Code Marking YWW = Date Code Marking Y = Last Digit of Year (ex: 6 for 2016) WW = Week Code (01 to 53) AB = Foundry and Assembly Code US1JDF / US1MDF Document number: DS36877 Rev. 9 - 2 1 of 5 www.diodes.com May 2016 © Diodes Incorporated US1JDF/US1MDF Maximum Ratings (@TA = +25°C, unless otherwise specified.) Single phase, half wave, 60Hz, resistive or inductive load. For capacitance load, derate current by 20%. Characteristic Peak Repetitive Reverse Voltage Working Peak Reverse Voltage DC Blocking Voltage (Note 5) RMS Reverse Voltage Average Rectified Output Current @TT = +25°C Non-Repetitive Peak Forward Surge Current 8.3ms Single Half Sine-Wave Superimposed on Rated Load Symbol VRRM VRWM VR VR(RMS) IO US1JDF US1MDF Unit 600 1,000 V 700 1.0 V A 30 A 420 IFSM Thermal Characteristics Characteristic Typical Thermal Resistance, Junction to Terminal (Note 8) Typical Thermal Resistance, Junction to Ambient (Note 8) Operating and Storage Temperature Range Symbol RJT RJA TJ, TSTG Value 44 80 -55 to +150 Unit °C/W °C/W °C Electrical Characteristics (@TA = +25°C, unless otherwise specified.) Characteristic Minimum Reverse Breakdown Voltage (Note 5) Maximum Forward Voltage Drop Peak Reverse Current at Rated DC Blocking Voltage (Note 5) Maximum Reverse Recovery Time (Note 6) Typical Total Capacitance (Note 7) Notes: @IR = 5μA @ IF = 1.0A @TA = +25°C @TA = +100°C US1JDF 600 US1MDF 1,000 Unit V V 1.7 5.0 100 75 10 IR tRR CT μA ns pF 5. Short duration pulse test used to minimize self-heating effect. 6. Measured with IF = 0.5A, IR = 1.0A, IRR = 0.25A. See figure 7. 7. Measured at 1.0MHz and applied reverse voltage of 4.0V DC. 8. Device mounted on FR-4 substrate, 1" * 1", 2oz, single-sided, PC boards with 0.1"*0.15" copper pads. 9. Device mounted on FR-4 substrate, 0.4" * 0.5", 2oz, single-sided, PC boards with 0.2"*0.25" copper pads. IF, INSTANTANEO US FORWARD CURRENT (A) 1.20 I F, DC FORWARD CURRENT (A) Symbol V(BR)R VF 1 0.80 Note 9 0.60 Note 8 0.40 0.20 0 0 25 50 75 100 125 TA, AMBIENT TEMPERATURE (°C) Figure 1 Forward Current Derating US1JDF / US1MDF Document number: DS36877 Rev. 9 - 2 150 10 TA = 150°C T A = 125°C 1 T A = 100°C TA = 85°C 0.1 T A = 25°C T A = -55°C 0.01 0.5 1.0 1.5 2.0 2.5 3.0 VF , INSTANTANEOUS FORWARD VOLTAGE (V) Figure 2 Typical Forward Characteristics 2 of 5 www.diodes.com May 2016 © Diodes Incorporated IR, INSTANTANEOUS REVERSE CURRENT (µA) 40 30 20 10 0 1 10 100 NUMBER OF CYCLES AT 60Hz Fig. 3 Forward Surge Current Derating Curve PF(av), Average Forward Power Dissipation (W) 20 CT , TOTAL CAPACITANCE (pF) f=1MHz 15 10 5 0 0 1 10 V R, DC REVERSE VOLTAGE (V) Figure 5 Total Capacitance P F(AV), AVERAG E FORWARD POWER DI SSI PATION (W) IFSM, PEAK FORWARD SURGE CURRENT (A) US1JDF/US1MDF 100 100 T A = 150°C 10 T A = 125°C T A =100°C 1 T A = 85°C 0.1 T A = 25°C 0.01 TA = -55°C 0.001 20 40 60 80 100 PERCENT OF RATED PEAK REVERSE VOLTAGE (%) Figure 4 Typical Reverse Characteristics 1.2 TJ = 150°C 1 0.8 0.6 0.4 0.2 Note 8 0 0 0.2 0.4 0.6 0.8 1 1.2 IF(AV) AVERAGE FORWARD CURRENT (A) Figure 6 Forward Power Dissipation Figure 7 Reverse Recovery Time Characteristic and Test Circuit US1JDF / US1MDF Document number: DS36877 Rev. 9 - 2 3 of 5 www.diodes.com May 2016 © Diodes Incorporated US1JDF/US1MDF Package Outline Dimensions Please see http://www.diodes.com/package-outlines.html for the latest version. D-FLAT HE E L k D-FLAT Dim Min Max A 0.90 1.10 b 1.25 1.65 c 0.10 0.40 D 2.25 2.95 E 3.95 4.60 k 2.80 – 5.00 5.60 HE L 0.50 1.30 All Dimensions in mm b D A c Suggested Pad Layout Please see http://www.diodes.com/package-outlines.html for the latest version. D-FLAT X1 X Dimensions C G X X1 Y Y G Value (in mm) 4.65 2.80 1.85 6.50 1.70 C US1JDF / US1MDF Document number: DS36877 Rev. 9 - 2 4 of 5 www.diodes.com May 2016 © Diodes Incorporated US1JDF/US1MDF IMPORTANT NOTICE DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. This document is written in English but may be translated into multiple languages for reference. Only the English version of this document is the final and determinative format released by Diodes Incorporated. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright © 2016, Diodes Incorporated www.diodes.com US1JDF / US1MDF Document number: DS36877 Rev. 9 - 2 5 of 5 www.diodes.com May 2016 © Diodes Incorporated