Download

Connector-Terminal Block Conversion Unites
XW2R Series
Speedy
Get Waste-free Connections in the Ideal Style
Excellent
3
Universal
Select from
Different Styles
Select from Three Styles of Units for a Dramatic
Are You Wasting Work, Time, and Space Connecting to
FA LCON
Speedy
Extreme Savings in Wiring
Power supply terminals help you dramatically
save work in wiring with only one terminal block.
Units with Power Supply Terminals for PLCs
S WA L L OW
Excellent
Extremely Easy to Connect
A wiring pattern that is specialized for PLCs reduces
work and mistakes in checking signal layouts.
Units for PLCs
+
Common Terminal Block
PIGEON
Universal
Outstanding Adaptability
Adaptability means you can handle all types of applications,
helping to reduce the number of stocked parts.
Units for General-purpose Devices
2
Savings in Wiring and Wiring Work
Connector-Terminal Block Conversion Units?
Total Length
Superior (186.7mm)
INDEX
Connection Work
Superior (8 min, 56 s)
Features
Features
Specialized for connecting PLCs;
power terminals provided.
Flexibility
Reasonable
Details
Page 4
2
Selecting Connector-Terminal Block Conversion
4
Units for PLCs and for General-purpose Device
8
Variations in Connection and Installation Methods
Selecting Cables for Connector-Terminal
Block Conversion Units
10
Connector-Terminal Block Conversion Units for PLCs
OMRON PLCs
Total Length
Connection Work
Good (227.3mm)
Units with Power Supply Terminals
12
Units without Power Supply Terminals
19
Good (9 min, 14 s)
Mitsubishi PLCs
Features
Flexibility
Specialized for connecting PLCs.
Units with Power Supply Terminals
23
Units without Power Supply Terminals
28
Reasonable
Keyence PLCs
Details
Page 5
Units with Power Supply Terminals
32
Units without Power Supply Terminals
34
General-purpose Connector-Terminal Block Conversion Units
Total Length
Reasonable (242.3mm)
Connection Work
Reasonable (12 min, 26 s)
Features
Wire connectors and terminal
blocks connected 1:1.
Flexibility
Superior
Details
Page 5
Units with Power Supply Terminals
39
Units without Power Supply Terminals
41
Common Terminal Blocks
44
Cables for Connector-Terminal Block Conversion Units
Shielded Cables
49
Unshielded Cables
57
Screw-mounting Connector-Terminal
Block Conversion Units
67
*Results of OMRON comparison for 32 I/O points.
3
Speedy
Extreme Savings in Wiring
Dramatically reduce wiring and wiring work. Increase work standardization.
Ideal for connecting to PLCs from just about any company.
Wiring method
Type
Units with Power Supply
Terminals for PLCs
Push-in
spring
e-CON
Connector-Terminal Block Conversion Units with Power Supply Terminals
XW2R-□□□ GD-□□-COM
XW2R-N □□ GD-C □-COM
XW2R-P□□ GD-□□-COM
The Units for inputs and outputs are
different colors for easy recognition.
Units available for OMRON,
Mitsubishi, and Keyence PLCs.
A wiring pattern that is specialized for PLCs
reduces work in checking signal layouts.
PLC addresses are provided on the terminal blocks.
Connector pins not used for PLCs were
eliminated to minimize the number of pins
and thereby reduce the size.
XW2R-P□□ GD-□□-COM
The signal, positive(+) voltage, and negative(−) voltage lines
can be wired together to save space and work.
Signal line
To PLC
Positive(+)
Positive power line
Negative(−)
power line
Negativ
Horizontal rows are
internally connected.
Sensor or actuator
a
Are You Wasting Time Removing Sheaths from Sensor Cables?
Positive(+) voltage relay terminal block
Negative(−) voltage relay terminal block
Using a Conversion Unit with
Power Supply Terminals
Signal terminal block
Work time is shortened
because it is not necessary
to remove the sheath.
Footprint Reduced by 53%
Wiring Work Reduced by 60%
The Conversion Unit is 53% more compact than a configuration
of relay terminal blocks and a signal terminal block.
positive(+) voltage relay
terminal block
Negative(−) voltage relay
terminal block
Loosening screws
Inserting short bars
Signal terminal block
Traditional screw
terminal block
992 s
No need
for crossovers
and screw
tightening!
402.7mm
XW2R-COM
186.7mm
53% More Compact!
Connector-Terminal
Block Conversion Units
Conne
with Power Supply Terminals
4
Connecting
Reduced by 60%!
400 s
0
200
400
600
800
1000
1200 (s)
*Results of OMRON comparison for Unit with 32 push-in spring connections.
Excellent
Extremely Easy to Connect
Ideal for connecting to PLCs from various companies.
Wiring method
Type
Units for PLCs
Push-in
spring
Phillips
screws
Slotted screws
(rise-up)
Connector-Terminal Block Conversion Units for PLCs
XW2R-□□□ GD-□□
We recommend
a common
terminal block.
Details: Page 6
XW2R-P□□ GD-□□
XW2R-J □□ GD-□□
XW2R-E34GD-□□
Units available for OMRON,
Mitsubishi, and Keyence PLCs.
A wiring pattern that is specialized for
PLCs reduces work in checking signal layouts.
Terminal block signal labels give the PLC addresses.
Connector pins not used for PLCs were eliminated to
minimize the number of pins and therefore the size.
Terminal Block Signal Labels Give the PLC addresses
Unit for
OMRON PLC
Unit for
Mitsubishi PLC
Unit for
Keyence PLC
Universal
Outstanding Adaptability
Just one series for easy selection with high versatility to handle various applications.
Wiring method
Type
Units for
General-purpose Devices
Push-in
spring
Connector
Phillips
screws
Slotted screws
(rise-up)
MIL
connector
FCN
connector
Connector-Terminal Block Conversion Units for General-purpose Devices
XW2R-□□□□ D-T
XW2R-P□□□ D-T
XW2R-J □□□ D-T
XW2R-E□□□ D-T
Wire Connectors and Terminal Blocks 1:1
Applicable with PLCs from any manufacturer.
Models available with 20, 34, 40, 50, and 60 poles.
5
Common Terminal Block
Achieve downsizing and reduce work by push-in spring connector .
Wiring method
Type
Units for Generalpurpose Devices
Push-in
spring
Common Terminal Block
XW2R-P40□ D-COM
For Positive(+) Voltages
For Negative(−) Voltages
Positive(+) and Negative(−) Connections
XW2R-P40PD-COM
XW2R-P40MD-COM
XW2R-P40BD-COM
Ideal for I/O commons to connect 2-wire devices.
Ideal for connecting 3-wire devices.
Cable
XW2Z
Easy connections with less clutter around power supplies.
Commons are wired on the PCB to eliminate the need to wire crossovers.
Push-in spring connections.
Select Units for Positive(+) Voltages, Negative(−) Voltages, or Both.
For Positive(+) Voltages
For Negative(−) Voltages
Power Supply
S8
□□
Connector Terminal Block for Signals
XW2R- 34GD-C
□
□
Are Your Control Panels Buried in
DIN Track Screw Terminal Blocks?
Save space
with common
terminal blocks.
Footprint Reduced by 43%
Wiring Work Reduced by 70%
Loosening screws
Inserting short bars
Traditional DIN
Track screw
terminal block
110.5mm
400 s
No need
for crossovers
and screw
tightening!
64.4mm
43% More Compact
Connecting
XW2R-COM
128 s
Reduced by 70%!
Than DIN Track Screw
Terminal Blocks
0
*Comparison based on number of possible common connections
for DIN Track screw terminal blocks with 8.5-mm pitch.
6
100
200
300
400
500
(s)
*Based on OMRON testing to estimate work for 32 common connections.
A Wide Range of connectors and Poles to Match Installation Needs
Units for PLCs
□□□□□-□□-COM
Units without Power Supply Terminals : XW2R-□□□□□-□□
Units with Power Supply Terminals : XW2R-
Replace
□ with the model codes in the following table.
Units with Power Supply Terminals
Push-in spring
Units without Power Supply Terminals
e-CON
MIL connector
Push-in spring
Phillips screws
Slotted screws
(rise up)
Wiring method
I/O points
16
32
16
32
-
32
32
32
P16GD-C1
P32GD-C1
N16GD-C1
N32GD-C1
-
P34GD-C1
J34GD-C1
E34GD-C1
-
P32GD-C2
N32GD-C2
-
P34GD-C2
J34GD-C2
E34GD-C2
P16GD-C3
P32GD-C3
P34GD-C3
J34GD-C3
E34GD-C3
-
P34GD-C4
J34GD-C4
E34GD-C4
P34GD-M1
J34GD-M1
E34GD-M1
P34GD-M2
J34GD-M2
E34GD-M2
P34GD-K1
J34GD-K1
P40GD-K2 *
J40GD-K2 *
OMRON PLCs
-
-
P32GD-C4
P32GD-M1
Mitsubishi PLCs
-
-
-
G32GD-M1
P32GD-M2
Keyence PLCs
P32GD-K1
-
-
-
-
-
*The XW2R-P40GD-K2 and XW2R-J40GD-K2 provide 40 poles each.
Units for General-purpose Devices
Units with Power Supply Terminals : XW2R-N08GD-COM
Units without Power Supply Terminals : XW2R-
□□□□□-T
Units with
Power Supply Terminals
Replace
□ with the model codes in the following table.
Units without Power Supply Terminals
e-CON
Push-in spring
Phillips screws
Slotted screws (rise up)
-
20,34,40,50,60
20,34,40,50,60
20,34,40,50,60
P20GD
J20GD
E20GD
P34GD
J34GD
E34GD
P40GD
J40GD
E40GD
P50GD
J50GD
E50GD
P60GD
J60GD
E60GD
P40FD
J40FD
E40FD
Wiring method
Mounted connector
number of poles
MIL
connector
FCN
connector
XW2R-N08GD-COM
-
7
Select the Installation Method and Terminal Wiring Method.
Select the Wiring Method
How Many Times is
Retightening Necessary?
Push-in spring
Wiring, inspections, shipping, maintenance...
Just Push in the Wire for a Sure Connection
Connect any of 3 types of wires.
Ferrules
Retightening is not required for
push-in spring connections.
Solid wires
Testers can be inserted in the release holes.
Stranded wires
*Blade terminals can also be used. Provide insulation.
Flat mark-tubes can be used.
Thick wires can be used
(AWG28 to AWG14 (0.08 to 2.0 mm2 )).
*AWG24 to AWG14 for ferrules.
(However, the outer diameter of the insulation must be 4 mm max.)
Easy, Fast Connection and Removal by Just about Anyone
Ferrules
Naked Wires
Just press the ferrule all the way in.
You're done.
Removal
Insert a tool into the release hole.
Insert the wire while the tool is inserted.
Remove the tool, and you're done.
Insert a tool into the release
hole and pull out the wire.
Remove the tool.
Select the Installation Method
Mounting
Removal
Units That Mount to DIN Track
Move
screwdriver
like a lever.
Mounting and Removal are
Fast and Easy with DIN Track
Press.
Catch.
Catch the Terminal Block on the DIN Track.
Press down on the Terminal Block to mount it.
8
Insert.
Insert a flat-blade screwdriver into the DIN Track lock.
Move the screwdriver like a lever to free the lock.
A Wealth of OMRON Connector Variations
Tensile Strength Meets IEC Standard
Greatly Reduce Connection Work!
(IEC60947-7-1 Standard)
(s)
15
Just insert the wire!
Actual value of tensile strength is equivalent to screw connections.
IEC standard
(cable diameter)
Screwless
connection
Screw
connection
125 N
112 N
20 N min.
(AWG20)
10
5
4s
*The values for screwless and screw connections are
actual values measures by OMRON for the XW2R.
Phillips screws
Slotted screws (rise-up)
Terminal blocks are shipped with the screws open for immediate connection.
The cover can be locked open for better work efficiency.
Both round and forked crimp terminals can be used, and screws will not fall out.
Vertical Screw Mounting*
Forked
crimp
terminals
Ferrules
Reduce Wiring Mistakes!
(Phillips screws)
XW2R-
Round
crimp
terminals
e-CON
Traditional Screw Terminal Blocks Are
Also Available
Different Models for
Different Installation Methods
0
□□□□□-□
Standard connectors for sensor inputs that mate
with e-CON connectors from other manufacturers.
Easy to connect and ideal for standardization.
The following codes are used for this
□ in the model number.
D: For DIN Track
V: Vertical screw mounting
Blank: Horizontal screw mounting
Horizontal Screw Mounting*
Select the Best Type for Actual Case of Use
Vertical screw mounting
Horizontal
orizontal screw mounting
All Models Mount to DIN Track
The ribs for screw mounting are positioned within the DIN Track so that they do not interfere
with DIN Track mounting parts or End Plates. Even when connecting Horizontal Mounting Units
to each other, the ribs do not interfere so there is no gap between the Units.
* For details, refer to page 67.
9
Cables for Connector-Terminal Block Conversion Units
Shielded Cables Model numbers (common portion) : XW2Z-
□□□□
Replace
□ with the model codes in the following table.
Cable length
Connector
Connector
0.25m
0.5m
1m
1.5m
2m
3m
5m
7m
10m
15m
20m
FCN connector,
24 poles
MIL connector,
20 poles
-
050A
100A
150A
200A
300A
500A
700A
010A
15MA
20MA
FCN connector,
40 poles
MIL connector,
20 poles ×2*
-
-
100D
150D
200D
300D
500D
-
010D
15MD
20MD
FCN connector,
40 poles
MIL connector,
20 poles ×2*
-
-
100L
150L
200L
300L
500L
-
010L
15ML
20ML
FCN connector,
40 poles
MIL connector,
40 poles
-
050B
100B
150B
200B
300B
500B
700B
010B
15MB
20MB
MIL connector,
14 poles
MIL connector,
14 poles
-
050AA
100AA
-
200AA
-
500AA
-
010AA
-
-
MIL connector,
20 poles
MIL connector,
20 poles
-
C50X
100X
-
200X
300X
500X
-
010X
-
-
MIL connector,
20 poles
Loose wires with crimp
terminals, 20 poles
-
-
100F
150F
200F
300F
500F
-
010F
15MF
20MF
MIL connector,
40 poles
MIL connector,
20 poles ×2
-
-
100N
150N
200N
300N
500N
-
010N
15MN
20MN
MIL connector,
34 poles
MIL connector,
34 poles
-
050EE
100EE
150EE
200EE
300EE
500EE
-
-
-
-
MIL connector,
40 poles
MIL connector,
40 poles
C25K
C50K
100K
150K
200K
300K
500K
-
010K
-
-
*The wiring is different. Refer to page 52 for details.
Unshielded Cables Model numbers (common portion) : XW2Z-
□□□□□□-L□□
Replace
□ with the model codes in the following table.
Cable length
Connector
Connector
0.3m
0.5m
0.75m
1m
1.5m
2m
3m
4m
5m
7m
10m
FCN connector,
24 poles
MIL connector,
20 poles
-
0050AD
-L
-
0100AD
-L
-
0200AD
-L
0300AD
-L
-
-
-
-
FCN connector,
40 poles
MIL connector,
20 poles ×2*
-
-
-
0100BH
-L01
0150BH
-L01
0200BH
-L01
0300BH
-L01
0400BH
-L01
0500BH
-L01
-
-
FCN connector,
40 poles
MIL connector,
20 poles ×2*
-
-
-
0100BH
-L02
0150BH
-L02
0200BH
-L02
0300BH
-L02
0400BH
-L02
0500BH
-L02
-
-
FCN connector,
40 poles
MIL connector,
40 poles
-
0050BF
-L
-
0100BF
-L
0150BF
-L
0200BF
-L
0300BF
-L
-
0500BF
-L
0700BF
-L
1000BF
-L
FCN connector,
56 poles
MIL connector,
20 poles ×3*
-
-
-
-
0150CJ
-L01
0200CJ
-L01
0300CJ
-L01
-
-
-
-
FCN connector,
56 poles
MIL connector,
20 poles ×3*
-
-
-
-
0150CJ
-L02
0200CJ
-L02
0300CJ
-L02
-
-
-
-
FCN connector,
56 poles
MIL connector,
40 poles + 20 poles
-
-
-
-
0150CK-L01
0150CK-L02
0200CK-L01
0200CK-L02
-
-
-
-
-
FCN connector,
56 poles
MIL connector,
60 poles
-
-
-
0100CG
-L
-
0200CG
-L
0300CG
-L
-
-
-
-
MIL connector,
20 poles
MIL connector,
20 poles
-
0050DD
-L
-
0100DD
-L
-
0200DD
-L
-
-
-
-
-
MIL connector,
34 poles
MIL connector,
34 poles
-
0050EE
-L
-
0100EE
-L
0150EE
-L
0200EE
-L
0300EE
-L
-
0500EE
-L
0700EE
-L
1000EE
-L
MIL connector,
40 poles
MIL connector,
20 poles ×2*
-
-
0075FH
-L01
0100FH
-L01
-
0200FH
-L01
0300FH
-L01
-
0500FH
-L01
-
-
MIL connector,
40 poles
MIL connector,
20 poles ×2*
-
-
0075FH
-L02
0100FH
-L02
-
0200FH
-L02
0300FH
-L02
-
0500FH
-L02
-
-
MIL connector,
40 poles
MIL connector,
40 poles
0030FF
-L
0050FF
-L
-
0100FF
-L
0150FF
-L
0200FF
-L
0300FF
-L
-
0500FF
-L
0700FF
-L
1000FF
-L
*The wiring is different. Refer to page 57 for details.
10
Connector-Terminal Block Conversion Units for PLCs
XW2R
Connector-Terminal Block
Conversion Units Designed
Specifically to Connect PLCs
• Wiring patterns that are specifically designed for PLCs
reduce the work required to check signal layout.
• Terminal block signal labels give the PLC addresses.
• Models available with Phillips screw, slotted screw,
push-in, or e-CON connections.
• Models available with and without power supply
terminals.
• Mounting to DIN Track is possible.
Models that are mounted with screws are also available.
Refer to page 67.
Item
With
power supply
terminals
Without
power supply
terminals
PLC Maker
OMRON
Mitsubishi
Keyence
Model
XW2R-@@@GD-C@-COM
XW2R-@32GD-M@-COM
XW2R-P32GD-K1-COM
Page
Page 12
Page 23
Page 32
Model
XW2R-@34GD-C@
XW2R-@34GD-M@
XW2R-@@@GD-K@
Page
Page 19
Page 28
Page 34
Appearance
Appearance
Options (Order Separately)
Connecting Cables for Connector-Terminal Block Conversion Units
Refer to page 49.
11
XW2R
Models for Connection to OMRON PLCs with power supply terminals
Model List
X W 2 R - @ @ @ G D - C @ - COM
Wiring method
I/O Points
P
16 16 Points
N
Push-in spring
e-CON Type
Mounted Connector type
G
MIL (XG4A)
32 32 Points
Mounting method
D
DIN Track mounting
PLC type
Power supply terminals
C1 Refer to the
C2 following table for
16-pole models
C3 and to page 13 for
C4 32-pole models.
COM
Provided
Models for OMRON PLCs
Models with 16 Poles
I/O
I/O Points
32
Input
64
16
I/O Unit Model
CJ1W-ID231
CS1W-ID231
CJ1W-ID261
CS1W-ID261
CJ1W-MD231 (inputs)
Models that connect to PLCs
Connecting cables ∗
XW2R-P16GD-C1-COM: 2 pcs
XW2R-N16GD-C1-COM: 2 pcs
XW2Z-@@@D: 1 Cable
XW2R-P16GD-C1-COM: 4 pcs
XW2R-N16GD-C1-COM: 4 pcs
XW2Z-@@@D: 2 Cables
XW2R-P16GD-C1-COM: 1 pcs
XW2R-N16GD-C1-COM: 1 pcs
XW2Z-@@@A: 1 Cable
XW2R-P16GD-C1-COM: 2 pcs
XW2R-N16GD-C1-COM: 2 pcs
XW2Z-@@@D: 1 Cable
XW2R-P16GD-C1-COM: 2 pcs
XW2R-N16GD-C1-COM: 2 pcs
XW2Z-@@@N: 1 Cable
XW2R-P16GD-C1-COM: 4 pcs
XW2R-N16GD-C1-COM: 4 pcs
XW2Z-@@@N: 2 Cables
XW2R-P16GD-C3-COM: 2 pcs
XW2Z-@@@L: 1 Cable
XW2R-P16GD-C3-COM: 2 pcs
XW2Z-@@@N: 2 Cables
XW2R-P16GD-C3-COM: 4 pcs
XW2Z-@@@L: 2 Cables
XW2R-P16GD-C3-COM : 4 pcs
XW2Z-@@@N: 2 Cables
XW2R-P16GD-C3-COM: 1 pcs
XW2Z-@@@A: 1 Cable
XW2R-P16GD-C3-COM: 2 pcs
XW2Z-@@@L: 1 Cable
CJ1W-MD261 (inputs)
I/O
32
CS1W-MD261 (inputs)
CS1W-MD262 (inputs)
CS1W-MD561 (inputs)
CJ1W-ID232
Input
32
I/O
Input
CJ1W-ID233
CJ1W-MD263 (inputs)
CJ1W-MD563 (inputs)
64
CJ1W-ID262
CJ1W-OD231
CS1W-OD231
32
CS1W-OD232
CJ1W-OD232
CJ1W-OD233
Output
CJ1W-OD234
CJ1W-OD261
64
CS1W-OD261
CJ1W-OD262
CJ1W-OD263
16
CJ1W-MD231 (outputs)
CJ1W-MD261 (outputs)
I/O
32
CS1W-MD261 (outputs)
CS1W-MD262 (outputs)
CS1W-MD561 (outputs)
* @@@ is replaced by the cable length. Refer to page 49.
Note: Connection is not possible to all OMRON PLC Units.
This Connector-Terminal Block Conversion Unit is for NPN. For PNP, reverse the polarity of the external power supply and I/O on the
Connector-Terminal Block Conversion Unit.
12
XW2R
Models with 32 Poles
I/O
I/O Points
32
Input
64
I/O
32
32
Input
64
I/O
32
32
Output
64
I/O
32
32
Output
64
I/O
32
I/O Unit Model
CJ1W-ID231
CS1W-ID231
CJ1W-ID261
CS1W-ID261
CJ1W-MD261 (inputs)
CS1W-MD261 (inputs)
CS1W-MD262 (inputs)
CS1W-MD561 (inputs)
CJ1W-ID232
CJ1W-ID233
CJ1W-ID262
CJ1W-MD263 (inputs)
CJ1W-MD563 (inputs)
CJ1W-OD231
CS1W-OD231
CS1W-OD232
CJ1W-OD261
CS1W-OD261
CS1W-OD262
CJ1W-MD261 (outputs)
CS1W-MD261 (outputs)
CS1W-MD262 (outputs)
CS1W-MD561 (outputs)
CJ1W-OD232
CJ1W-OD233
CJ1W-OD234
CJ1W-OD262
CJ1W-OD263
CJ1W-MD263 (outputs)
CJ1W-MD563 (outputs)
Connecting cables ∗
Models that connect to PLCs
XW2R-P32GD-C1-COM: 1 pcs
XW2R-N32GD-C1-COM: 1 pcs
XW2Z-@@@B: 1 Cable, or
XW2Z-@@@@BF-L: 1 Cable
XW2R-P32GD-C1-COM: 2 pcs
XW2R-N32GD-C1-COM: 2 pcs
XW2Z-@@@B: 2 Cables, or
XW2Z-@@@@BF-L: 2 Cables
XW2R-P32GD-C1-COM: 1 pcs
XW2R-N32GD-C1-COM: 1 pcs
XW2Z-@@@B: 1 Cable, or
XW2Z-@@@@BF-L: 1 Cable
XW2R-P32GD-C2-COM: 1 pcs
XW2R-N32GD-C2-COM: 1 pcs
XW2Z-@@@K: 1 Cable, or
XW2Z-@@@@FF-L: 1 Cable
XW2R-P32GD-C2-COM: 2 pcs
XW2R-N32GD-C2-COM: 2 pcs
XW2Z-@@@K: 2 Cables, or
XW2Z-@@@@FF-L: 2 Cables
XW2R-P32GD-C2-COM: 1 pcs
XW2R-N32GD-C2-COM: 1 pcs
XW2Z-@@@K: 1 Cable, or
XW2Z-@@@@FF-L: 1 Cable
XW2R-P32GD-C3-COM: 1 pcs
XW2Z-@@@B: 1 Cable, or
XW2Z-@@@@BF-L: 1 Cable
XW2R-P32GD-C3-COM: 2 pcs
XW2Z-@@@B: 2 Cables, or
XW2Z-@@@@BF-L: 2 Cables
XW2R-P32GD-C3-COM: 1 pcs
XW2Z-@@@B: 1 Cable, or
XW2Z-@@@@BF-L: 1 Cable
XW2R-P32GD-C4-COM: 1 pcs
XW2Z-@@@K: 1 Cable, or
XW2Z-@@@@FF-L: 1 Cable
XW2R-P32GD-C4-COM: 2 pcs
XW2Z-@@@K: 2 Cables, or
XW2Z-@@@@FF-L: 2 Cables
XW2R-P32GD-C4-COM: 1 pcs
XW2Z-@@@K: 1 Cable, or
XW2Z-@@@@FF-L: 1 Cable
* @@@@ is replaced by the cable length.
Note: Connection is not possible to all OMRON PLC Units.
This Connector-Terminal Block Conversion Unit is for NPN. For PNP, reverse the polarity of the external power supply and I/O on the
Connector-Terminal Block Conversion Unit.
Connection Examples
32-point Input Unit or Output Unit
CJ1W-ID231 32-point
CJ1W-OD231 32-point
64-point Input Unit or Output Unit
CJ1W-ID261 64-point
CJ1W-OD261 64-point
Connection to 32 pts unit
(Without branch)
XW2Z-@@@B or
XW2Z-@@@@BF-L
Connection to 64 pts unit
(Without branch)
XW2Z-@@@B or
XW2Z-@@@@BF-L
64-point I/O Unit
CJ1W-MD563 IN 32 Points, OUT 32 Points
Connection to 64 pts unit
(Without branch)
XW2Z-@@@K or
XW2Z-@@@@FF-L
outputs
inputs
13
XW2R
Models for Connection to OMRON PLCs with power supply terminals
Application Example
Power Supply
Connections to Sensors and Actuators
Can be used as crossovers
to the next Unit.
PLC Connecting Cables
XW2Z-@@@B, XW2Z-@@@@BF-L
Connectors: One 40-pin Connector Made by Fujitsu Component, Ltd. to One 40-pin MIL Connector
Appearance
Cable length L (m)
0.5
1
1.5
2
3
5
7
10
15
20
With shield
Model
XW2Z-050B
XW2Z-100B
XW2Z-150B
XW2Z-200B
XW2Z-300B
XW2Z-500B
XW2Z-700B
XW2Z-010B
XW2Z-15MB
XW2Z-20MB
Without shield
Model
XW2Z-0050BF-L
XW2Z-0100BF-L
XW2Z-0150BF-L
XW2Z-0200BF-L
XW2Z-0300BF-L
XW2Z-0500BF-L
XW2Z-0700BF-L
XW2Z-1000BF-L
-----
Wiring Diagram
FCN367J040-AU/F
(mating side)
1
1
2
2
XG4M-4030-T
(mating side) Triangular
mark
2
1
4
3
10 10
20 19
11 11
22 21
19 19
38 37
20 20
40 39
B
A
Cable length L (m)
L
XW2Z-@@@K, XW2Z-@@@@FF-L
Connectors: One 40-pin Connector to One 40-pin MIL Connector
Appearance
Cable length L (m)
0.25
0.5
1
1.5
2
3
5
7
10
With shield
Model
XW2Z-C25K
XW2Z-C50K
XW2Z-100K
XW2Z-150K
XW2Z-200K
XW2Z-300K
XW2Z-500K
--XW2Z-010K
Without shield
Model
--XW2Z-0050FF-L
XW2Z-0100FF-L
XW2Z-0150FF-L
XW2Z-0200FF-L
XW2Z-0300FF-L
XW2Z-0500FF-L
XW2Z-0700FF-L
XW2Z-1000FF-L
Wiring Diagram
XG4M-4030-T
(mating side)
XG4M-4030-T
(mating side) Triangular
mark
39 40
2
1
37 38
4
3
21
22
20 19
19
20
22 21
3
4
38 37
1
2
40 39
Triangular mark
Note: Wire the connector terminals 1:1 so that
the connector terminal numbers coincide.
Cable length L (m)
L
14
XW2R
Models for Connection to OMRON PLCs with power supply terminals
Push-in spring
Ordering Information
Appearance∗
I/O Points
16
Input/Output
Model
Dimension A (mm)
Input
XW2R-P16GD-C1-COM
Output
XW2R-P16GD-C3-COM
98.5
XW2R-P32GD-C1-COM
Input
XW2R-P32GD-C2-COM
32
186.7
XW2R-P32GD-C3-COM
Output
XW2R-P32GD-C4-COM
* Input models (XW2R-P@@GD-C1/C2-COM) are black and output models (XW2R-P@@GD-C3/C4-COM) are green.
Ratings and Specifications
Rated current
Rated voltage
Insuration resistance
Dielectric strength
Ambient operating
temperature
Applicable
Applicable wire sizes
wires
Stripped
length
Details on Crimp Terminals
Square ferrules
Applicable Ferrules
16 Points: 1A/signal, 4A/common
32 Points: 1A/signal, 8A/common
24VDC
100MΩ min. (at 500VDC)
500VAC for 1 ferrulemin
(leakage current: 1 mA max.)
B
• Use ferrules of the lengths and thicknesses
specified below.If other lengths or thicknesses
are used, connection maynot be possible or it
may not be possible to insert or remove the
posts.
8-10 mm
A
Round ferrules
Dia. C
8-10 mm
• Ferrule Dimensions
0 to 55°C
Square
ferrules
AWG 24 to 14 (ferrules)
AWG 28 to 14 (stranded or solid)
(Outer diameter of insulation must be
4 mm max)
AWG28-16: 8 to 10 mm
AWG14: 9 to 10 mm
Round
ferrules
Dimension A
(Width)
2.7 mm max.
Dimension B
(Height)
2 mm max.
Dimension C
(Diameter)
2 mm dia. max. (after crimping)
The cross-sectional area
after crimping must be
4.8 mm2 or less
Refer to page 46 for information on Square/Round ferrule and use tool.
Dimensions
(Unit: mm)
The label contents
depend on the model.
The label contents
depend on the model.
MIL Plug: XG4A-2031
A
50
(44.81)
19.7
(33.1)
15
XW2R
Models for Connection to OMRON PLCs with power supply terminals
Wiring Diagram
XW2R-P16GD-C1-COM
XW2R-P16GD-C3-COM
MIL Connector
MIL Connector
(0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15)
(NC)
(0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15)
(NC)
(NC)
(V)
(V)
(G)
(G)
External power supply
(NC)
External power supply
Terminal Block
XW2R-P32GD-C1-COM
Terminal Block
XW2R-P32GD-C2-COM
MIL Connector
MIL Connector
(0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15)
(NC)
(0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15)
(NC)
(NC)
(V)
(V)
(G)
(G)
External power supply
(NC)
External power supply
Terminal Block
XW2R-P32GD-C3-COM
Terminal Block
XW2R-P32GD-C4-COM
MIL Connector
MIL Connector
(0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15)
(NC)
(0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15)
(NC)
(NC)
(V)
(V)
(G)
(G)
External power supply
(NC)
External power supply
Terminal Block
Terminal Block
Label Contents
XW2R-P32GD-C1-COM, XW2R-P32GD-C3-COM
XW2R-P32GD-C2-COM, XW2R-P32GD-C4-COM
XW2R-P16GD-C1-COM
XW2R-P16GD-C3-COM
16
NC
0
1
2
3
4
5
6
7
8
9
10
11 12 13 14 15 NC
NC 0
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G
1
2
V V V
4
5
6
V V
3
V
V V V V
7
8
9 10 11 12 13 14 15 0
V
V V
V V V
V
2
3
4
V V
1
V
V V V
5
6
7
8
9 10 11 12 13 14 15 NC
V V V
V V V V V V V
XW2R
Models for Connection to OMRON PLCs with power supply terminals
e-CON Type
Ordering Information
Appearance
I/O Points
Input/Output
16
Input
Model
Dimension A (mm)
XW2R-N16GD-C1-COM
98.5
XW2R-N32GD-C1-COM
32
186.7
XW2R-N32GD-C2-COM
Ratings and Specifications
Power supply terminal block: 4 A/16 poles or 8 A/32 poles
Connectors/e-CON Connectors: 1 A
(However, rated current of e-CON Connector depends on the wires that are used.)
Rated voltage
24VDC
Insuration resistance
100MΩ min. (at 500VDC)
Dielectric strength
500VAC for 1 min (leakage current: 1 mA max.)
Ambient operating temperature 0 to 55°C
AWG 24 to 14 (ferrules)
Applicable wire
AWG 28 to 14 (stranded wires)
sizes
AWG 28 to 16 (solid wires)∗
Applicable
(Outer diameter of insulation must be 4 mm max)
wires
AWG28-16: 8 to 10 mm
Stripped length
AWG14: 9 to 10 mm
* This is the applicable range for the power supply terminal block. For the applicable wire sizes for I/O Connectors (e-CON), refer to page 37.
Rated current
Refer to page 37 for the recommended e-CON Connectors.
Dimensions
(Unit: mm)
Two power supply
terminal blocks
MIL Plug:XG4A-@@31
(44.81)
A
(33.1)
50
7.5
e-CON Sockets:
XN2D-4471: 4 sockets/16 poles
8 sockets/32 poles
19.7
The label contents
depend on the model.
(30.8)
17
XW2R
Models for Connection to OMRON PLCs with power supply terminals
Wiring Diagram
XW2R-N16GD-C1-COM
MIL Connector
External power supply
External power supply
e-CON
XW2R-N32GD-C1-COM
Connector
External power supply
External power supply
e-CON
XW2R-N32GD-C2-COM
Connector
External power supply
External power supply
e-CON
18
XW2R
Models for Connection to OMRON PLCs without power supply terminals
Model List
X W 2 R - @ 34 G D - C @
Wiring method
Number of poles
J
Phillips screw
E
Slotted screw (rise up)
P
Push-in spring
34
34 poles
(I/O points: 32 points)
Mounted Connector type
G
MIL (XG4A)
Mounting method
D
PLC type
DIN Track mounting
C1
C2
C3
C4
Refer to the
following
table for details.
Models for OMRON PLCs
I/O
I/O Points
32
Input
64
I/O Unit Model
CJ1W-ID231
CS1W-ID231
CJ1W-ID261
CS1W-ID261
Models that connect to PLCs ∗1
Connecting cables ∗2
XW2R-@34GD-C1: 1 pcs
XW2Z-@@@B: 1 Cable, or
XW2Z-@@@@BF-L: 1 Cable
XW2R-@34GD-C1: 2 pcs
XW2Z-@@@B: 2 Cables, or
XW2Z-@@@@BF-L: 2 Cables
XW2R-@34GD-C1: 1 pcs
XW2Z-@@@B: 1 Cable, or
XW2Z-@@@@BF-L: 1 Cable
XW2R-@34GD-C2: 1 pcs
XW2Z-@@@K: 1 Cable, or
XW2Z-@@@@FF-L: 1 Cable
XW2R-@34GD-C2: 2 pcs
XW2Z-@@@K: 2 Cables, or
XW2Z-@@@@FF-L: 2 Cables
XW2R-@34GD-C2: 1 pcs
XW2Z-@@@K: 1 Cable, or
XW2Z-@@@@FF-L: 1 Cable
XW2R-@34GD-C3: 1 pcs
XW2Z-@@@B: 1 Cable, or
XW2Z-@@@@BF-L: 1 Cable
XW2R-@34GD-C3: 2 pcs
XW2Z-@@@B: 2 Cables, or
XW2Z-@@@@BF-L: 2 Cables
XW2R-@34GD-C3: 1 pcs
XW2Z-@@@B: 1 Cable, or
XW2Z-@@@@BF-L: 1 Cable
XW2R-@34GD-C4: 1 pcs
XW2Z-@@@K: 1 Cable, or
XW2Z-@@@@FF-L: 1 Cable
XW2R-@34GD-C4: 2 pcs
XW2Z-@@@K: 2 Cables, or
XW2Z-@@@@FF-L: 2 Cables
XW2R-@34GD-C4: 1 pcs
XW2Z-@@@K: 1 Cable, or
XW2Z-@@@@FF-L: 1 Cable
CJ1W-MD261 (inputs)
I/O
32
CS1W-MD261 (inputs)
CS1W-MD262 (inputs)
CS1W-MD561 (inputs)
32
Input
64
I/O
32
CJ1W-ID232
CJ1W-ID233
CJ1W-ID262
CJ1W-MD263 (inputs)
CJ1W-MD563 (inputs)
CJ1W-OD231
32
CS1W-OD231
CS1W-OD232
Output
CJ1W-OD261
64
CS1W-OD261
CS1W-OD262
CJ1W-MD261 (outputs)
I/O
32
CS1W-MD261 (outputs)
CS1W-MD262 (outputs)
CS1W-MD561 (outputs)
CJ1W-OD232
32
CJ1W-OD234
Output
64
I/O
CJ1W-OD233
32
CJ1W-OD262
CJ1W-OD263
CJ1W-MD263 (outputs)
CJ1W-MD563 (outputs)
*1 Replace the box (@) with the wiring method code (J, E, or P).
*2 @@@@ is replaced by the cable length. For details, refer to page 14.
Note: 1. Connection is not possible to all OMRON PLC Units.
2. There is one common for each 32 points.
19
XW2R
Models for Connection to OMRON PLCs without power supply terminals
Phillips screw
Ordering Information
Appearance
I/O Points (Number of poles)
Model
XW2R-J34GD-C1
XW2R-J34GD-C2
32 (34)
XW2R-J34GD-C3
XW2R-J34GD-C4
Ratings and Specifications
Rated current
Rated voltage
Insuration resistance
Dielectric strength
Ambient operating
temperature
Applic
able
wires
Details on Crimp Terminals
Wiring Terminal Blocks
• Using Crimp Terminals (With a Terminal
Block with M3 Screws)
Terminal Screw Tightening Torque
• Use a tightening torque of 0.5 N·m when
connecting wires or crimp terminals to
the terminal block.
0.5 A/signal, 4 A/common
24VDC
100MΩ min. (at 500VDC)
500VAC for 1 min
(leakage current: 1 mA max.)
0 to 55°C
Applicable crimp terminals
AWG 22 to 16 (round or forked crimp
Applicable wire
terminals)
sizes
AWG 26 to 16 (stranded or solid wires)
Stripped length 9 mm
Tightening
0.5 N·m
Dimensions
(Unit: mm)
5.8 mm max.
Forked crimp terminals
3.2 mm
5.8 mm max.
Applicable wires
Round crimp terminals
1.25-3
AWG 22 to 16 (0.30 to 1.25 mm2)
Forked crimp terminals
1.25Y-3
AWG 22 to 16 (0.30 to 1.25 mm2)
Wiring Diagram
XW2R-J34GD-C1
MIL Plug:XG4A-4031
Round crimp terminals
3.2 mm dia.
XW2R-J34GD-C2
MIL Connector
130.7
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
50
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
MIL Connector
(00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
(NC)
M3
3.5
7 (Pitch)
The label contents
depend on the model.
2 4 6 8 10 12 14 16 20 22 24 26 28 30 32 34
17/18 1 3 5 7 9 11 13 15 19 21 23 25 27 29 31 33
35/36 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
(COM)
(NC)
1/2 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
21/22 20 18 16 14 12 10 8 6 19 17 15 13 11 9 7 5
(COM)
3/4 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
23/24 40 38 36 34 32 30 28 26 39 37 35 33 31 29 27 25
5.8
Terminal Block
Terminal Block
XW2R-J34GD-C3
XW2R-J34GD-C4
MIL Connector
MIL Connector
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
(44.81)
(+V)
(+V)
19/20 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
39/40 2 4 6 8 10 12 14 16 22 24 26 28 30 32 34 36
(0V)
17/18 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
37/38 1 3 5 7 9 11 13 15 21 23 25 27 29 31 33 35
Terminal Block
19.7
(48.05)
Label Contents
XW2R-J34GD-C1, XW2R-J34GD-C2
20
XW2R-J34GD-C3, XW2R-J34GD-C4
1/2 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
21/22 20 18 16 14 12 10 8 6 19 17 15 13 11 9 7 5
(0V)
3/4 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
23/24 40 38 36 34 32 30 28 26 39 37 35 33 31 29 27 25
Terminal Block
XW2R
Models for Connection to OMRON PLCs without power supply terminals
Slotted screw (rise up)
Ordering Information
Appearance
I/O Points (Number of poles)
Model
XW2R-E34GD-C1
XW2R-E34GD-C2
32 (34)
XW2R-E34GD-C3
XW2R-E34GD-C4
Ratings and Specifications
Rated current
Rated voltage
Insuration resistance
Dielectric strength
Ambient operating
temperature
Applicable wire
Appli sizes
cable
Stripped length
wires
Tightening
Details on Crimp Terminals
0.5 A/signal, 4 A/common
24VDC
100MΩ min. (at 500VDC)
500VAC for 1 min
(leakage current: 1 mA max.)
Applicable crimp
terminals
Rod
0 to 55°C
Blade
AWG 22 to 16 (ferrules)
AWG 26 to 16 (stranded or solid wires)
7 mm
0.5 to 0.6 N·m
Dimensions
(Unit: mm)
TC-05
Dia. = 1
Round rod
Dia.
AWG22 to AWG18
(0.30 to 0.75 mm2)
TC-1.25S
Dia. = 1.5
AWG22 to AWG16
(0.30 to 1.25 mm2)
BT1.25-9-1
BT1.25-10-1
W = 2.2
AWG22 to AWG16
(0.30 to 1.25 mm2)
8-10 mm
Blade
t = 0.75
8-10 mm
W
Note: Round rod and blade crimp terminals are made by Nichifu.
Wiring Diagram
XW2R-E34GD-C1
MIL Plug: XG4A-4031
Applicable wires
XW2R-E34GD-C2
MIL Connector
MIL Connector
98.5
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
50
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
(00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
(NC)
The label contents
depend on the model.
2.5
5 (Pitch)
2 4 6 8 10 12 14 16 20 22 24 26 28 30 32 34
17/18 1 3 5 7 9 11 13 15 19 21 23 25 27 29 31 33
35/36 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
(COM)
(NC)
1/2 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
21/22 20 18 16 14 12 10 8 6 19 17 15 13 11 9 7 5
(COM)
3/4 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
23/24 40 38 36 34 32 30 28 26 39 37 35 33 31 29 27 25
Terminal Block
XW2R-E34GD-C3
Terminal Block
XW2R-E34GD-C4
MIL Connector
MIL Connector
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
(44.81)
(+V)
(+V)
19/20 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
39/40 2 4 6 8 10 12 14 16 22 24 26 28 30 32 34 36
1/2 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
21/22 20 18 16 14 12 10 8 6 19 17 15 13 11 9 7 5
(0V)
(0V)
17/18 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
37/38 1 3 5 7 9 11 13 15 21 23 25 27 29 31 33 35
Terminal Block
3/4 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
23/24 40 38 36 34 32 30 28 26 39 37 35 33 31 29 27 25
Terminal Block
19.7
(43)
Label Contents
XW2R-E34GD-C1, XW2R-E34GD-C2
XW2R-E34GD-C3, XW2R-E34GD-C4
21
XW2R
Models for Connection to OMRON PLCs without power supply terminals
Push-in spring
Ordering Information
Appearance
I/O Points (Number of poles)
Model
XW2R-P34GD-C1
XW2R-P34GD-C2
32 (34)
XW2R-P34GD-C3
XW2R-P34GD-C4
Ratings and Specifications
Rated current
Rated voltage
Insuration resistance
Dielectric strength
Ambient operating
temperature
Stripped
length
Square ferrules
0.5 A/signal, 4 A/common
24VDC
100MΩ min. (at 500VDC)
500VAC for 1 min
(leakage current: 1 mA max.)
Applicable Ferrules
• Use ferrules of the lengths and thicknesses
specified below.If other lengths or
thicknesses are used, connection maynot
be possible or it may not be possible to
insert or remove the posts.
0 to 55°C
Ferrule Dimensions
AWG 24 to 14 (ferrules)
AWG 28 to 14 (stranded or solid)
(Outer diameter of insulation must be
4 mm max)
AWG28-16: 8 to 10 mm
AWG14: 9 to 10 mm
Applicable
wire sizes
Applicable
wires
Details on Crimp Terminals
Dimensions
(Unit: mm)
Square
ferrules
Round
ferrules
8-10 mm
A
Round ferrules
Dia. C
Dimension A
(Width)
2.7 mm max.
Dimension B
(Height)
2 mm max.
Dimension C
(Diameter)
2 mm dia. max. (after crimping)
8-10 mm
The cross-sectional area
after crimping must be
4.8 mm2 or less
Refer to page 46 for information on Square/Round ferrule and use tool.
Wiring Diagram
XW2R-P34GD-C1
MIL Plug:XG4A-4031
B
XW2R-P34GD-C2
MIL Connector
MIL Connector
98.5
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
50
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
1&
&20
(00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
(NC)
2 4 6 8 10 12 14 16 20 22 24 26 28 30 32 34
17/18 1 3 5 7 9 11 13 15 19 21 23 25 27 29 31 33
35/36 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
(COM)
The label contents
depend on the model.
5 (Pitch)
(NC)
1/2 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
21/22 20 18 16 14 12 10 8 6 19 17 15 13 11 9 7 5
(COM)
3/4 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
23/24 40 38 36 34 32 30 28 26 39 37 35 33 31 29 27 25
Terminal Block
XW2R-P34GD-C3
Terminal Block
XW2R-P34GD-C4
MIL Connector
MIL Connector
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
(44.81)
(+V)
(+V)
19/20 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
39/40 2 4 6 8 10 12 14 16 22 24 26 28 30 32 34 36
(0V)
17/18 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
37/38 1 3 5 7 9 11 13 15 21 23 25 27 29 31 33 35
Terminal Block
19.7
(33.1)
Label Contents
XW2R-P34GD-C1, XW2R-P34GD-C2
m+1
22
XW2R-P34GD-C3, XW2R-P34GD-C4
m+1
1/2 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
21/22 20 18 16 14 12 10 8 6 19 17 15 13 11 9 7 5
(0V)
3/4 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15)
23/24 40 38 36 34 32 30 28 26 39 37 35 33 31 29 27 25
Terminal Block
XW2R
Models for Connection to Mitsubishi PLCs with power supply terminals
Model List
X W 2 R - @ 3 2 G D - M @ - COM
Wiring method
P Push-in spring
I/O Points
32 32 Points
Mounted Connector type
G MIL (XG4A)
Mounting method
D DIN Track mounting
G MIL Connector
PLC type
Power supply terminals
M1 Refer to the following
M2 table for details.
COM
Provided
Models for Connection to Mitsubishi PLCs
I/O Points
Mitsubishi PLC Module model
Connecting cables ∗
Models that connect to PLCs
LX41C4
QX41
QX41-S1
32
QX41-S2
XW2R-P32GD-M1-COM: 1 pcs
XW2Z-@@@B: 1 Cable, or
XW2Z-@@@@BF-L: 1 Cable
XW2R-P32GD-M1-COM: 2 pcs
XW2Z-@@@B: 2 Cables, or
XW2Z-@@@@BF-L: 2 Cables
XW2R-P32GD-M2-COM: 1 pcs
XW2Z-@@@B: 1 Cable, or
XW2Z-@@@@BF-L: 1 Cable
XW2R-P32GD-M2-COM: 2 pcs
XW2Z-@@@B: 2 Cables, or
XW2Z-@@@@BF-L: 2 Cables
QX71
QH42P (Input)
QX41Y41P (Input)
LX42C4
QX42
64
QX42-S1
QX82
QX82-S1
LY41NT1P
QY41P
32
QY71
QH42P (Output)
QX41Y41P (Output)
LY42NT1P
64
QY42P
QY82P
* @@@@ is replaced by the cable length.
Note: This Connector-Terminal Block Conversion Unit is for NPN. For PNP, reverse the polarity of the external power supply and I/O on the
Connector-Terminal Block Conversion Unit.
XW2Z-@@@B, XW2Z-@@@@BF-L
Connectors: One 40-pin Connector Made by Fujitsu Component, Ltd. to One 40-pin MIL Connector
Appearance
Wiring Diagram
Cable length L
(m)
With shield
Without shield
Model
Model
0.5
XW2Z-050B
XW2Z-0050BF-L
1
XW2Z-100B
XW2Z-0100BF-L
1.5
XW2Z-150B
XW2Z-0150BF-L
2
XW2Z-200B
XW2Z-0200BF-L
3
XW2Z-300B
XW2Z-0300BF-L
5
XW2Z-500B
XW2Z-0500BF-L
7
XW2Z-700B
XW2Z-0700BF-L
10
XW2Z-010B
XW2Z-1000BF-L
15
XW2Z-15MB
---
19 19
20
XW2Z-20MB
---
20 20
FCN367J040-AU/F
(mating side)
1
1
2
2
2
1
4
3
10 10
20 19
11 11
22 21
38 37
40 39
B
Cable length L (m)
XG4M-4030-T
(mating side) Triangular
mark
A
L
23
XW2R
Models for Connection to Mitsubishi PLCs with power supply terminals
MIL Connector
Models for Connection to Mitsubishi PLCs
I/O Points
Model
Models that connect to PLCs
32
QH42P (Input) , QX41Y41P (Input)
XW2R-G32GD-M1-COM: 1 pcs
XW2R-G32GD-M1-COM: 2 pcs
Connection A
XW2Z-@@@B: 2 Cables, or
XW2Z-@@@@BF-L: 2 Cables
Connection B
XW2Z-@@@AA: 8 Cables
LX41C4
QX42, QX42-S1, QX82, QX82-S1
64
Connecting cables∗
Connection A
XW2Z-@@@B: 1 Cable, or
XW2Z-@@@@BF-L: 1 Cable
Connection B
XW2Z-@@@AA: 4 Cables
QX41, QX41-S1, QX41-S2, QX71
LX42C4
* @@@@ is replaced by the cable length.
Note: Refer to page 23 for information on the XW2Z-@@@B and XW2Z-@@@@BF-L.
This Connector-Terminal Block Conversion Unit is for NPN. For PNP, reverse the polarity of the external power supply and I/O on the
Connector-Terminal Block Conversion Unit.
XW2Z-@@@AA One 14-pin MIL Connector to One 14-pin MIL Connector
Appearance
Wiring Diagram
With shield
Cable length L (m)
Model
0.5
XW2Z-050AA
1
XW2Z-100AA
2
XW2Z-200AA
5
XW2Z-500AA
10
XW2Z-010AA
Cable length L (m)
L
Note: Wire the connector terminals 1:1 so that
the connector terminal numbers coincide.
Connection Examples
controller
Connection A
XW2Z-@@@B or
XW2Z-@@@@BF-L
The 32 PLC inputs are
separated into groups
of 8 inputs.
XW2R-G32GD-M1-COM
Connection B
XW2Z-@@@AA
By distributing the input locations,
less work is required for changes
to sensors and other devices.
XW2R-N08GD-COM
(e-CON Connectors: 4 poles × 8)
XN2A-1470
(e-CON Connector: 4 poles)
Connection to sensor
Relay Connector
XN2B-1470
(e-CON Connector: 4 poles)
24
XN2A-1470
(e-CON Connector: 4 poles)
XW2R
Models for Connection to Mitsubishi PLCs with power supply terminals
Ordering Information
Appearance
Model
Number of poles
40 poles x 1 point
14 poles x 4 points
XW2R-G32GD-M1-COM
Ratings and Specifications
Rated current
Power supply terminal block: 8A
Connectors: 1A
Rated voltage
24VDC
Insuration resistance
100MΩ min. (at 500VDC)
Dielectric strength
500VAC for 1 min
(leakage current: 1 mA max.)
Ambient operating
temperature
0 to 55°C
Applicable
wires
Wiring Diagram
MIL Connector
External
power
supply
AWG 24 to 14 (ferrules)
AWG 28 to 14 (stranded wires)
Applicable
AWG 28 to 16 (solid wires)
wire sizes
(Outer diameter of insulation must be 4
mm max)
Stripped
length
AWG28-16: 8 to 10 mm,
AWG14: 9 to 10 mm
MIL Connector
MIL Connector
MIL Connector
MIL Connector
Dimensions
(Unit: mm)
Power supply terminal block
MIL Plug: XG4A-4031
98.5
G
G
50
V
V
44.8
MIL Plug:
XG4A-1431
19.7
(33.1)
25
XW2R
Models for Connection to Mitsubishi PLCs with power supply terminals
Ordering Information
Appearance
I/O Points
Number of poles
(PLC end)
I/O
Model
8 points
14 poles
Input
XW2R-N08GD-COM
Ratings and Specifications
Rated voltage
Insuration resistance
Dielectric strength
Ambient operating
temperature
0 to 55°C
Applicable wire
Applicable sizes ∗
wires
Stripped length
XG4A-1431 (PLC end)
XN2D-4471 (for input)
Cable Connector
model
XG4M-1430-T (PLC end)
XN2A-1470 (for input)
Wiring Diagram
Power supply terminal block: 2A
Connectors/e-CON Connectors: 1 A
(However, rated current of e-CON Connector
depends on the wires that are used.)
24VDC
100MΩ min. (at 500VDC)
500VAC for 1 min (leakage current: 1 mA max.)
Rated current
Mounted Connector
model
MIL Connector
External
power
supply
AWG 24 to 14 (ferrules), AWG 28 to 14 (stranded
wires), AWG 28 to 16 (solid wires)
(Outer diameter of insulation must be 4 mm max)
AWG28-16: 8 to 10 mm, AWG14: 9 to 10 mm
* This is the applicable range for the power supply terminal block. For the applicable
wire sizes for I/O Connectors (e-CON), refer to page 37.
e-CON
(This connection diagram is for combining with CN1
on the XW2R-G32GD-M1-COM.)
Refer to page 37 for the recommended e-CON Connectors.
Dimensions
Power supply terminal block
(Unit: mm)
MIL Plug: XG4A-1431
64.4
G
V
G
50
V
(44.8)
19.7
e-CON Sockets: XN2D-4471 × 2
(30.8)
(33.1)
The e-CON address assignments are for combining the XW2R-G32GD-M1-COM with four XW2R-N08GD-COM.
26
CN3
CN4
CN1
CN2
XW2R
Models for Connection to Mitsubishi PLCs with power supply terminals
Push-in spring
Ordering Information
Appearance
I/O Points
Input/Output
Model
Input
XW2R-P32GD-M1-COM
Output
XW2R-P32GD-M2-COM
32 points
Ratings and Specifications
Rated current
Rated voltage
Insuration resistance
Dielectric strength
Ambient operating
temperature
Details on Crimp Terminals
Applicable Ferrules
1 A/signal, 8 A/common
24VDC
100MΩ min. (at 500VDC)
500VAC for 1 min (leakage current: 1 mA max.)
8-10 mm
A
Round ferrules
Dia. C
8-10 mm
• Ferrule Dimensions
Square
ferrules
AWG 24 to 14 (ferrules)
AWG 28 to 14 (stranded or solid)
(Outer diameter of insulation must be 4 mm max)
AWG28-16: 8 to 10 mm
AWG14: 9 to 10 mm
Appli
cable
wires Stripped
length
B
• Use ferrules of the lengths and thicknesses
specified below.If other lengths or thicknesses
are used, connection maynot be possible or it
may not be possible to insert or remove the posts.
0 to 55°C
Applicable
wire sizes
Square ferrules
Round
ferrules
Dimension A (Width)
Dimension B (Height)
Dimension C
(Diameter)
2.7 mm max. The cross-sectional
area after crimping must
2 mm max.
be 4.8 mm2 or less
2 mm dia. max. (after crimping)
Refer to page 46 for information on Square/Round ferrule and use tool.
Dimensions
(Unit: mm)
The label contents
depend on the model.
The label contents
depend on the model.
MIL Plug: XG4A-4031
(44.81)
NC 00
01
02
03
0B 0C 0D 0E 0F 10
11
12
13
14
15
16
17
18
19
1A 1B 1C 1D 1E 1F NC
V
V
V
V
V
V
04
V
05
V
06
V
07
V
08
V
09 0A
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
Terminal block word mCH side (warm gray)
50
186.7
Terminal block word (m+1)CH side (light gray)
19.7
(33.1)
Wiring Diagram
XW2R-P32GD-M1-COM
XW2R-P32GD-M2-COM
MIL Connector
External power supply
Terminal Block
MIL Connector
External power supply
Terminal Block
Label Contents
XW2R-P32GD-M1-COM, XW2R-P32GD-M2-COM
Row 1
Row 2
Row 3
mC H
(m+1)CH
NC 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F NC
V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V
G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G
27
XW2R
Models for Connection to Mitsubishi PLCs without power supply terminals
Model List
X W 2 R - @ 34 G D - M @
Wiring method
Number of poles
J
34 poles
34 (I/O points: 32 points)
Phillips screw
E Slotted screw (rise up)
Mounted Connector type
G MIL (XG4A)
Mounting method
PLC Type
D DIN Track mounting
M1 Refer to the following
M2 table for details.
P Push-in spring
Models for Connection to Mitsubishi PLCs
PLC Type
I/O Points
Mitsubishi PLC Module model
Models that connect to PLCs ∗1
Connecting cables ∗2
LX41C4
QX41
QX41-S1
32
QX41-S2
XW2R-@34GD-M1: 1 pcs
XW2Z-@@@B: 1 Cable, or
XW2Z-@@@BF-L: 1 Cable
XW2R-@34GD-M1: 2 pcs
XW2Z-@@@B: 2 Cables, or
XW2Z-@@@@BF-L: 2 Cables
XW2R-@34GD-M2: 1 pcs
XW2Z-@@@B: 1 Cable, or
XW2Z-@@@@BF-L: 1 Cable
XW2R-@34GD-M2: 2 pcs
XW2Z-@@@B: 2 Cables, or
XW2Z-@@@@BF-L: 1 Cable
QX71
QH42P (Input)
M1
QX41Y41P (Input)
LX42C4
QX42
64
QX42-S1
QX82
QX82-S1
LY41NT1P
QY41P
32
QY71
QH42P (Output)
M2
QX41Y41P (Output)
LY42NT1P
QY42P
64
QY82P
*1 Replace the box (@) with the wiring method code (J, E, or P).
*2 @@@@ is replaced by the cable length.
XW2Z-@@@B, XW2Z-@@@@BF-L
Connectors: One 40-pin Connector Made by Fujitsu Component, Ltd. to One 40-pin MIL Connector
Appearance
With shield
Model
Model
0.5
XW2Z-050B
XW2Z-0050BF-L
1
XW2Z-100B
XW2Z-0100BF-L
1.5
XW2Z-150B
XW2Z-0150BF-L
2
XW2Z-200B
XW2Z-0200BF-L
3
XW2Z-300B
XW2Z-0300BF-L
5
XW2Z-500B
XW2Z-0500BF-L
10 10
7
XW2Z-700B
XW2Z-0700BF-L
11 11
10
XW2Z-010B
XW2Z-1000BF-L
15
XW2Z-15MB
---
19 19
20
XW2Z-20MB
---
20 20
FCN367J040-AU/F
(mating side)
1
1
2
2
L
XG4M-4030-T
(mating side) Triangular
mark
2
1
4
3
20 19
22 21
38 37
40 39
B
Cable length L (m)
28
Wiring Diagram
With shield
Cable length L (m)
A
XW2R
Models for Connection to Mitsubishi PLCs without power supply terminals
Phillips screw
Ordering Information
Appearance
I/O Points (Number of poles)
Model
XW2R-J34GD-M1
32 (34)
XW2R-J34GD-M2
Ratings and Specifications
Rated current
Rated voltage
Insuration resistance
Dielectric strength
Ambient operating
temperature
Applicable
Appli wire sizes
cable
Stripped length
wires
Tightening
Details on Crimp Terminals
0.5 A/signal, 2 A/common
24VDC
100MΩ min. (at 500VDC)
500VAC for 1 min (leakage current: 1 mA max.)
0 to 55°C
AWG 22 to 16 (round or forked crimp terminals)
AWG 26 to 16 (stranded or solid wires)
9 mm
0.5 N·m
Wiring Terminal Blocks
• Using Crimp Terminals (With a Terminal
Block with M3 Screws)
Terminal Screw Tightening Torque
• Use a tightening torque of 0.5 N·m when
connecting wires or crimp terminals to
the terminal block.
Applicable crimp terminals
Round crimp terminals
3.2 mm dia.
5.8 mm max.
Forked crimp terminals
3.2 mm
5.8 mm max.
Applicable wires
Round crimp terminals
1.25-3
AWG 22 to 16 (0.30 to 1.25 mm2)
Forked crimp terminals
1.25Y-3
AWG 22 to 16 (0.30 to 1.25 mm2)
Dimensions
(Unit: mm)
MIL Plug: XG4A-4031
130.7
50
(44.81)
M3
3.5
7 (Pitch)
19.7
The label contents
depend on the model.
5.8
(48.05)
Wiring Diagram
XW2R-J34GD-M2
XW2R-J34GD-M1
MIL Connector
MIL Connector
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
(COM)
2
39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 4
(10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (1A) (1B) (1C) (1D) (1E) (1F)
40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 1
3
(00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (0A) (0B) (0C) (0D) (0E) (0F)
(+V)
2
39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 4
(10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (1A) (1B) (1C) (1D) (1E) (1F)
40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 1
3
(00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (0A) (0B) (0C) (0D) (0E) (0F)
(0V)
(NC)
Terminal Block
Terminal Block
Label Contents
XW2R-J34GD-M1
XW2R-J34GD-M2
29
XW2R
Models for Connection to Mitsubishi PLCs without power supply terminals
Slotted screw (rise up)
Ordering Information
Appearance
I/O Points (Number of poles)
Model
XW2R-E34GD-M1
32 (34)
XW2R-E34GD-M2
Ratings and Specifications
Rated current
Rated voltage
Insuration resistance
Dielectric strength
Ambient operating
temperature
Applicable wire
Applic sizes
able
Stripped length
wires
Tightening
Details on Crimp Terminals
Applicable crimp
terminals
0.5 A/signal, 2 A/common
24VDC
100MΩ min. (at 500VDC)
500VAC for 1 min
(leakage current: 1 mA max.)
Rod
0 to 55°C
Blade
AWG 22 to 16 (ferrules)
AWG 26 to 16 (stranded or solid wires)
7 mm
0.5 to 0.6 N·m
TC-05
Dia. = 1
Applicable wires
Dia.
TC-1.25S
Dia. = 1.5
AWG22 to AWG16
(0.30 to 1.25 mm2)
BT1.25-9-1
BT1.25-10-1
W = 2.2
AWG22 to AWG16
(0.30 to 1.25 mm2)
W
(Unit: mm)
MIL Plug: XG4A-4031
(44.81)
50
The label contents
depend on the model.
19.7
2.5
5 (Pitch)
(43)
Wiring Diagram
XW2R-E34GD-M1
XW2R-E34GD-M2
MIL Connector
MIL Connector
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
(COM)
(+V)
(10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (1A) (1B) (1C) (1D) (1E) (1F) 2
39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 4
(10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (1A) (1B) (1C) (1D) (1E) (1F) 2
39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 4
40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 1
3
(00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (0A) (0B) (0C) (0D) (0E) (0F)
(00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (0A) (0B) (0C) (0D) (0E) (0F)
(NC)
40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 1
3
(0V)
Terminal Block
Label Contents
30
t = 0.75
Note: Round rod and blade crimp terminals are made by Nichifu.
98.5
XW2R-E34GD-M1
8-10 mm
Blade
8-10 mm
Dimensions
Terminal Block
Round rod
AWG22 to AWG18
(0.30 to 0.75 mm2)
XW2R-E34GD-M2
XW2R
Models for Connection to Mitsubishi PLCs without power supply terminals
Push-in spring
Ordering Information
Appearance
I/O Points (Number of poles)
Model
XW2R-P34GD-M1
32 (34)
XW2R-P34GD-M2
Ratings and Specifications
Rated current
Rated voltage
Insuration resistance
Dielectric strength
Ambient operating
temperature
Applicable
Applicable wire sizes
wires
Stripped
length
Details on Crimp Terminals
Square ferrules
Applicable Ferrules
• Use ferrules of the lengths and thicknesses
specified below.If other lengths or
thicknesses are used, connection maynot
be possible or it may not be possible to
insert or remove the posts.
0.5 A/signal, 2 A/common
24VDC
100MΩ min. (at 500VDC)
500VAC for 1 min
(leakage current: 1 mA max.)
B
8-10 mm
A
Round ferrules
Dia. C
8-10 mm
Ferrule Dimensions
0 to 55°C
AWG 24 to 14 (ferrules)
AWG 28 to 14 (stranded or solid)
(Outer diameter of insulation must be 4
mm max)
AWG28-16: 8 to 10 mm
AWG14: 9 to 10 mm
Square
ferrules
Round
ferrules
Dimension A
(Width)
2.7 mm max.
Dimension B
(Height)
2 mm max.
Dimension C
(Diameter)
2 mm dia. max. (after crimping)
The cross-sectional area
after crimping must be
4.8 mm2 or less
Refer to page 46 for information on Square/Round ferrule and use tool.
Dimensions
(Unit: mm)
MIL Plug: XG4A-4031
98.5
50
(44.81)
10
11
12
13
14
15
00
01
02
03
04
05
16
06
17
07
18
08
19
09
1A
0A
1B
1C
1D
1E
1F
COM
0B
0C
0D
0E
0F
NC
The label contents
depend on the model.
19.7
5 (Pitch)
(33.1)
Wiring Diagram
XW2R-P34GD-M1
XW2R-P34GD-M2
MIL Connector
MIL Connector
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
(+V)
(COM)
(10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (1A) (1B) (1C) (1D) (1E) (1F)
2
39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 4
40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 1
3
(00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (0A) (0B) (0C) (0D) (0E) (0F)
(10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (1A) (1B) (1C) (1D) (1E) (1F)
2
39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 4
40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 1
3
(00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (0A) (0B) (0C) (0D) (0E) (0F)
(0V)
(NC)
Terminal Block
Terminal Block
Label Contents
XW2R-P34GD-M1
XW2R-P34GD-M2
31
XW2R
Models for Keyence PLCs with power supply terminals
Model List
X W 2 R - P 3 2 G D - K 1 - COM
Wiring method
I/O Points
P Push-in spring
32 32 Points
Mounted Connector type
G
MIL (XG4A)
Mounting method
D DIN Track mounting
Power supply terminals
PLC Type
K1
Refer to the following
table for details.
COM
Provided
Models for Keyence PLCs
I/O
I/O Points
32
Input
64
Unit
Models for Keyence PLCs
Input Unit
Model
Models that connect to PLCs
Connecting cables∗
KV-C32XA, KV-C32XC
XW2R-P32GD-K1-COM:1 pcs
XW2Z-@@@EE: 1 Cable, or
XW2Z-@@@@EE-L: 1 Cable
KV-C64XA, KV-C64XB, KV-C64XC
XW2R-P32GD-K1-COM:2 pcs
XW2Z-@@@EE: 2 Cables, or
XW2Z-@@@@EE-L: 2 Cables
* @@@@ is replaced by the cable length.
Note: This Connector-Terminal Block Conversion Unit is for NPN. For PNP, reverse the polarity of the external power supply and I/O on the
Connector-Terminal Block Conversion Unit.
XW2Z-@@@EE, XW2Z-@@@EE-L
Connectors: One 34-pin MIL Connector to One 34-pin MIL Connector
Appearance
Cable length L (m)
Without shield
Model
Model
0.5
XW2Z-050EE
XW2Z-0050EE-L
1
XW2Z-100EE
XW2Z-0100EE-L
1.5
XW2Z-150EE
XW2Z-0150EE-L
2
XW2Z-200EE
XW2Z-0200EE-L
3
XW2Z-300EE
XW2Z-0300EE-L
5
XW2Z-500EE
XW2Z-0500EE-L
7
---
XW2Z-0700EE-L
10
---
XW2Z-1000EE-L
Cable length L (m)
L
32
With shield
Wiring Diagram
XG4M-3430-T
(mating side)
XG4M-3430-T
(mating side)
Triangular
mark
Triangular
mark
Note: Wire the connector terminals 1:1 so
that the connector terminal numbers
coincide.
XW2R
Models for Keyence PLCs with power supply terminals
Push-in spring
Ordering Information
Appearance
I/O Points
Model
32
XW2R-P32GD-K1-COM
Ratings and Specifications
Rated current
Rated voltage
Insuration resistance
Dielectric strength
Ambient operating
temperature
Applicable
Applicable wire sizes
wires
Stripped
length
Details on Crimp Terminals
Square ferrules
Applicable Ferrules
• Use ferrules of the lengths and thicknesses
specified below.If other lengths or
thicknesses are used, connection maynot
be possible or it may not be possible to
insert or remove the posts.
1 A/signal, 8 A/common
24VDC
100MΩ min. (at 500VDC)
500VAC for 1 min
(leakage current: 1 mA max.)
B
8-10 mm
A
Round ferrules
Dia. C
8-10 mm
• Ferrule Dimensions
0 to 55°C
AWG 24 to 14 (ferrules)
AWG 28 to 14 (stranded or solid)
(Outer diameter of insulation must be 4
mm max)
AWG28-16: 8 to 10 mm
AWG14: 9 to 10 mm
Square
ferrules
Round
ferrules
Dimension A
(Width)
2.7 mm max.
Dimension B
(Height)
2 mm max.
Dimension C
(Diameter)
2 mm dia. max. (after crimping)
The cross-sectional area
after crimping must be
4.8 mm2 or less
Refer to page 46 for information on Square/Round ferrule and use tool.
Dimensions
(Unit: mm)
The label contents depend on the model.
MIL Connector: XG4A-3431
186.7
50
(44.81)
19.7
Terminal block word mCH side (warm gray)
Terminal block word (m+1)CH side (light gray)
(33.1)
Wiring Diagram
XW2R-P32GD-K1-COM
MIL Connector
External power supply
Terminal Block
Label Contents
XW2R-P32GD-K1-COM
mCH
(m+1)CH
NC 000 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 NC
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G G
G
G
G
G
G
G
G
G
G
G
G
G
G
33
XW2R
Models for Keyence PLCs without power supply terminals
Model List
XW2R - @
Wiring method
Number of poles
@ @
G D - K @
Mounted Connector type
*1
J
Phillips screw
34 34 poles (I/O points: 32 points)
P
Push-in spring
40 40 poles (I/O points: 36 points)*2
G MIL (XG4A)
Mounting method
PLC Type
D DIN Track mounting
K1 Refer to the following
K2 table for details.
*1. K1 Type
*2. K2 Type
Models for Keyence PLCs
I/O
I/O Points
Unit
Output
Output
---
Connecting cables ∗2
KV-C32XA, KV-C32XC
KV-C32TA, KV-C32TC, KV-C32TCP
32
KV-C32TD
I/O Unit
Model
I/O
Input
Models that connect to PLCs ∗1
Models for Keyence PLCs
Input
XW2Z-@@@EE: 1 Cable, or
XW2Z-@@@@EE-L: 1 Cable
XW2R-@34GD-K1: 2 pcs
XW2Z-@@@EE: 2 Cables, or
XW2Z-@@@@EE-L: 2 Cables
XW2R-@40GD-K2: 1 pcs
XW2Z-@@@K: 1 Cable, or
XW2Z-@@@@FF-L: 1 Cable
KV-C32XTD
KV-C64XA, KV-C64XB, KV-C64XC
64
---
XW2R-@34GD-K1: 1 pcs
KV-C64TA, KV-C64TC, KV-C64TD, KV-C64TCP
CPU Unit
Model
KV-1000, KV-3000, KV-5000, KV-5500
*1 Replace the box (@) with the wiring method code (J or P).
*2 @@@@ is replaced by the cable length.
XW2Z-@@@EE, XW2Z-@@@@EE-L
Connectors: One 34-pin MIL Connector to One 34-pin MIL Connector
Appearance
Cable length L
(m)
0.5
1
1.5
2
3
5
7
10
With shield
Model
XW2Z-050EE
XW2Z-100EE
XW2Z-150EE
XW2Z-200EE
XW2Z-300EE
XW2Z-500EE
-----
Without shield
Model
XW2Z-0050EE-L
XW2Z-0100EE-L
XW2Z-0150EE-L
XW2Z-0200EE-L
XW2Z-0300EE-L
XW2Z-0500EE-L
XW2Z-0700EE-L
XW2Z-1000EE-L
Wiring Diagram
XG4M-3430-T
(mating side)
XG4M-3430-T
(mating side)
Triangular
mark
Triangular
mark
Cable length L (m)
Note: Wire the connector terminals 1:1 so that
the connector terminal numbers coincide.
L
XW2Z-@@@K, XW2Z-@@@@FF-L
Connectors: One 40-pin MIL Connector to One 40-pin MIL Connector
Appearance
Cable length L
(m)
0.25
0.5
1
1.5
2
3
5
7
10
Cable length L (m)
Without shield
Model
--XW2Z-0050FF-L
XW2Z-0100FF-L
XW2Z-0150FF-L
XW2Z-0200FF-L
XW2Z-0300FF-L
XW2Z-0500FF-L
XW2Z-0700FF-L
XW2Z-1000FF-L
Wiring Diagram
XG4M-4030-T
(mating side)
XG4M-4030-T
(mating side)
39 40
2
1
37 38
4
3
21 22
20 19
19 20
22 21
3
4
38 37
1
2
40 39
Triangular
mark
Triangular
mark
L
34
With shield
Model
XW2Z-C25K
XW2Z-C50K
XW2Z-100K
XW2Z-150K
XW2Z-200K
XW2Z-300K
XW2Z-500K
--XW2Z-010K
Note: Wire the connector terminals 1:1 so that
the connector terminal numbers coincide.
XW2R
Models for Keyence PLCs without power supply terminals
Phillips screw
Ordering Information
Appearance
I/O Points (Number of poles)
Model
Dimension A (mm)
32 (34)
XW2R-J34GD-K1
130.7
36 (40)
XW2R-J40GD-K2
151.7
Ratings and Specifications
Rated current
Rated voltage
Insuration
resistance
Dielectric strength
Ambient operating
temperature
Applicable
Applic wire sizes
Stripped
able
length
wires
Tightening
Details on Crimp Terminals
1A
125 VAC/DC
100MΩ min. (at 500VDC)
500VAC for 1 min (leakage current: 1 mA max.)
0 to 55°C
Wiring Terminal Blocks
• Using Crimp Terminals (With a Terminal
Block with M3 Screws)
Terminal Screw Tightening Torque
• Use a tightening torque of 0.5 N·m when
connecting wires or crimp terminals to
the terminal block.
Applicable crimp terminals
AWG 22 to 16 (round or forked crimp terminals)
AWG 26 to 16 (stranded or solid wires)
9 mm
Round crimp terminals
3.2 mm dia.
5.8 mm max.
Forked crimp terminals
3.2 mm
5.8 mm max.
Applicable wires
Round crimp terminals
1.25-3
AWG 22 to 16 (0.30 to 1.25 mm2)
Forked crimp terminals
1.25Y-3
AWG 22 to 16 (0.30 to 1.25 mm2)
0.5 N·m
Dimensions
(Unit: mm)
The label contents
depend on the model.
MIL Plug: XG4A-3431
A
50
(44.81)
3.5
7 (Pitch)
M3
19.7
5.8
(48.05)
Wiring Diagram
XW2R-J34GD-K1
MIL Connector
XW2R-J40GD-K2
MIL Connector
(100) (101) (102) (103) (104) (105) (106) (107) (108) (109) (110) (111) (112) (113) (114) (115) (COM1)
(21) (22) (23) (24) (25) (26) (27) (28) (29) (30) (31) (32) (33) (34) (35) (36) (37) (38) (39) (40)
(000) (001) (002) (003) (004) (005) (006) (007) (008) (009) (010) (011) (012) (013) (014) (015) (COM0)
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (20)
Terminal Block
Terminal Block
Label Contents
XW2R-J34GD-K1
XW2R-J40GD-K2
35
XW2R
Models for Keyence PLCs without power supply terminals
Push-in spring
Ordering Information
Appearance
I/O Points (Number of poles)
Model
Dimension A (mm)
32 (34)
XW2R-P34GD-K1
98.5
36 (40)
XW2R-P40GD-K2
113.5
Ratings and Specifications
Rated current
Rated voltage
Insuration resistance
Dielectric strength
Ambient operating
temperature
Appli
cable
wires
Applicable
wire sizes
Stripped
length
Details on Crimp Terminals
Applicable Ferrules
1A
AC/ DC125V
100MΩ min. (at 500VDC)
500VAC for 1 min (leakage current: 1 mA max.)
B
• Use ferrules of the lengths and thicknesses
specified below.If other lengths or thicknesses
are used, connection maynot be possible or it
may not be possible to insert or remove the posts.
AWG 24 to 14 (ferrules),
AWG 28 to 14 (stranded or solid wires)
(Outer diameter of insulation must be 4 mm max)
AWG28-16: 8 to 10 mm,
AWG14: 9 to 10 mm
2.7 mm max. The cross-sectional
area after crimping must
Dimension B (Height) 2 mm max.
be 4.8 mm2 or less
Square
ferrules
Dimension A (Width)
Round
ferrules
Dimension C
(Diameter)
2 mm dia. max. (after crimping)
Refer to page 46 for information on Square/Round ferrule and use tool.
Dimensions
(Unit: mm)
MIL Plug: XG4A-3431
(44.81)
50
A
100
101
102
103
104
105
000
001
002
003
004
005
106
006
107
108
109
110
111
112
113
114
115
COM1
007
008
009
010
011
012
013
014
015
COM0
The label contents
depend on the model.
5 (Pitch)
19.7
(33.1)
Wiring Diagram
XW2R-P34GD-K1
MIL Connector
XW2R-P40GD-K2
MIL Connector
(100) (101) (102) (103) (104) (105) (106) (107) (108) (109) (110) (111) (112) (113) (114) (115) (COM1)
(21) (22) (23) (24) (25) (26) (27) (28) (29) (30) (31) (32) (33) (34) (35) (36) (37) (38) (39) (40)
(000) (001) (002) (003) (004) (005) (006) (007) (008) (009) (010) (011) (012) (013) (014) (015) (COM0)
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (20)
Terminal Block
Terminal Block
Label Contents
XW2R-P34GD-K1
36
8-10 mm
A
Round ferrules
Dia. C
8-10 mm
• Ferrule Dimensions
0 to 55°C
Square ferrules
XW2R-P40GD-K2
XW2R
Input Device Connectors: XN2 e-CON Connectors
For Sensor
Relay Connector
Appearance
Number of poles
Model
4
XN2A-1470
Appearance
Number of poles
Model
4
XN2B-1470
Ratings and Specifications
Rated current
3 A/pin (with AWG20 wires), 2 A/pin (with AWG22 wires),
1 A/pin (with AWG24 wires), 0.5 A/pin (with AWG26 or AWG28 wires)
Rated voltage
32 VDC
Contact resistance
30 mΩ max. (at 20 mV, 100 mA max.)
Insuration resistance
103 MΩ min. (at 500VDC)
Dielectric strength
1,000 VAC for 60 sec (leakage current: 1 mA max.)
Insertion durability
50 times
Ambient operating
temperature
-30 to 75°C ∗
Applicable wires
Stranded wire 0.08mm2 (AWG28) to 0.5mm2 (AWG20)
(Outer diameter of insulation must be 1.5 mm max)
* The operating temperature range is restricted by the maximum operating temperature of the cable.
Wiring Procedure
Wire Preparation
Use the strip gauge on the
front panel and strip 7 to 8 mm
of the insulation. If you use
stranded wires, twist them
several times.
3. Insert a flat-blade screwdriver
into the release hole and
gently reset the lever. You
should hear the operation
lever reset.
Operation lever
(white)
Release
hole
7-8 mm
Connection Procedure
1. Press a flat-blade
screwdriver into the
operation hole until
the operation lever
locks into place.
Flat-blade
screwdriver
Operation
hole
2. Insert the wire all the way into the wire insertion hole. Confirm that
the insulation on the wire also enters the wire insertion hole and
that the end of the wire has passed through the connection
section.
Connection
section
Wire insulation
4. Finally, check the following items.
• Make sure the operation lever has been
reset.
• Check the items given in step 2 again.
(Pull lightly on the wire to see if it is held
firmly in place.)
Wire insertion
hole
Disconnection Procedure
1. Press in the operation level, confirm
that the operation lever is locked into
place, and then pull out the wire.
2. After you remove the wire, always
reset the operation lever. However, if
you are going to connect another wire
to the same terminal, you do not need
to reset the operation lever and can
immediately connect the other wire.
Operation
lever
(white)
37
Connector-Terminal Block Conversion Units for General-purpose Devices
XW2R
Many Variations in Connectors and
Number of Poles
• Models available with Phillips screw, slotted screw, push-in, or
e-CON connections.
• The terminal arrangement enables smoother wiring work.
• Push-in terminals simplify wiring and make the Terminal Blocks
even easier to use. (In comparison to the OMRON XW2F.)
• Mounting to DIN Track is possible.
Models that are mounted with screws are also available.
Refer to page 67.
Model List
With power supply terminals
X W 2R -
Wiring method
N
e-CON
I/O Points
G D - COM
Mounted Connector type
G
08
MIL (XG4A)
Mounting method
D
DIN Track mounting
Power supply terminals
COM
Provided
Without power supply terminals
X W 2R -
Wiring method
D - T
Number of poles
J
Phillips screw
20
G
MIL (XG4A)
E
Slotted screw (rise up)
34
F
FCN
P
Push-in spring
40
D
D-sub ∗
50
R
MR ∗
60
M
MDR ∗
Options (Order Separately)
Connecting Cables for Connector-Terminal Block Conversion Units
Refer to page 49.
38
Plug/Socket
Mounted Connector type
Blank Plug (male)
R
Mounting method
D
DIN Track mounting
Socket (female) ∗
∗ Consult your OMRON representative for these models.
XW2R
With power supply terminals
e-CON Type
Ordering Information
Appearance
I/O Points
I/O
Model
8 Points
Input
XW2R-N08GD-COM
Mounted Connector model
XG4A-1431 (MIL Connector)
XN2D-4471 (e-CON Connector)
Ratings and Specifications
XG4M-1430-T (MIL Connector)
XN2A-1470 (e-CON Connector)
Wiring Diagram
Rated current
Power supply terminal block: 2 A,
Connectors/e-CON Connectors: 1 A
(However, rated current of e-CON Connector
depends on the wires that are used.)
Rated voltage
24VDC
Insuration resistance
100MΩ min. (at 500VDC)
Dielectric strength
500VAC for 1 min (leakage current: 1 mA max.)
Ambient operating
temperature
0 to 55°C
MIL Connector
External
power
supply
AWG 24 to 14 (ferrules),
Applicable AWG 28 to 14 (stranded wires),
Applicable wire sizes∗ AWG 28 to 16 (solid wires)
(Outer diameter of insulation must be 4 mm max)
wires
Stripped
length
Cable Connector model
e-CON
AWG28-16: 8 to 10 mm
AWG14: 9 to 10 mm
* This is the applicable range for the power supply terminal block. For the
applicable wire sizes for I/O Connectors (e-CON), refer to page 40.
Dimensions
(Unit: mm)
Power supply
terminal block
MIL Plug:
XG4A-1431
64.4
50
(44.8)
19.7
e-CON Sockets:
XN2D-4471 x 2 sockets
(30.8)
(33.1)
39
XW2R
Input Device Connectors: XN2 e-CON Connectors
For Sensor
Appearance
Relay Connector
Number of
poles
Model
4
XN2A-1470
Appearance
Number of
poles
Model
4
XN2B-1470
Ratings and Specifications
Rated current
3 A/pin (with AWG20 wires), 2 A/pin (with AWG22 wires),
1 A/pin (with AWG24 wires), 0.5 A/pin (with AWG26 or AWG28 wires)
Rated voltage
32 VDC
Contact resistance
30 mΩ max. (at 20 mV, 100 mA max.)
Insuration resistance
103 MΩ min. (at 500VDC)
Dielectric strength
1,000 VAC for 60 sec (leakage current: 1 mA max.)
Insertion durability
50 times
Ambient operating
temperature
-30 to 75°C ∗
Applicable wires
Stranded wire 0.08mm2 (AWG28) to 0.5mm2 (AWG20)
(Outer diameter of insulation must be 1.5 mm max)
* The operating temperature range is restricted by the maximum operating temperature of the cable.
Wiring Procedure
Wire Preparation
3. Insert a flat-blade screwdriver
into the release hole and
gently reset the lever. You
should hear the operation
lever reset.
Use the strip gauge on the
front panel and strip 7 to 8 mm
of the insulation. If you use
stranded wires, twist them
several times.
Operation lever
(white)
Release hole
7 to 8 mm
Connection Procedure
1. Press a flat-blade
screwdriver into the
operation hole until
the operation lever
locks into place.
Flat-blade
screwdriver
Operation hole
2. Insert the wire all the way into the wire insertion hole. Confirm that
the insulation on the wire also enters the wire insertion hole and
that the end of the wire has passed through the connection
section.
Connection
section
Wire insulation
4. Finally, check the following items.
• Make sure the operation lever has been
reset.
• Check the items given in step 2 again.
(Pull lightly on the wire to see if it is held
firmly in place.)
Wire insertion
hole
Disconnection Procedure
1. Press in the operation level, confirm
that the operation lever is locked into
place, and then pull out the wire.
2. After you remove the wire, always
reset the operation lever. However, if
you are going to connect another wire
to the same terminal, you do not need
to reset the operation lever and can
immediately connect the other wire.
40
Operation
lever
(white)
XW2R
Without power supply terminals
Phillips screw
Ordering Information
Appearance∗
Mounted Connector model
MIL Connector
FCN Connector
Number of poles
Model
XG4A-2031
20
XW2R-J20GD-T
Dimension A (mm)
81.7
XG4A-3431
34
XW2R-J34GD-T
130.7
XG4A-4031
40
XW2R-J40GD-T
151.7
XG4A-5031
50
XW2R-J50GD-T
186.7
XG4A-6031
60
XW2R-J60GD-T
221.7
FCN-364P040-AU
40
XW2R-J40FD-T
151.7
* The mounted Connector shown in the appearance illustration is a MIL Connector.
Ratings and Specifications
Rated current
1A
Rated voltage
125 VAC, 24 VDC
Insuration resistance
100MΩ min.(at 500VDC)
Dielectric strength
500VAC for 1 min
(leakage current: 1 mA max.)
Ambient operating
temperature
0 to 55°C
Details on Crimp Terminals
Wiring Terminal Blocks
• Using Crimp Terminals (With a Terminal
Block with M3 Screws)
Terminal Screw Tightening Torque
• Use a tightening torque of 0.5 N·m when
connecting wires or crimp terminals to
the terminal block.
Applicable crimp terminals
AWG 22 to 16 (round or forked crimp
Applicable wire
terminals)
Applic sizes
AWG 26 to 16 (stranded or solid wires)
able
wires Stripped length 9 mm
Tightening
Round crimp terminals
3.2 mm dia.
5.8 mm max.
Forked crimp terminals
3.2 mm
5.8 mm max.
Applicable wires
Round crimp terminals
1.25-3
AWG 22 to 16 (0.30 to 1.25 mm2)
Forked crimp terminals
1.25Y-3
AWG 22 to 16 (0.30 to 1.25 mm2)
0.5 N·m
Dimensions
(Unit: mm)
Drawing is MIL Plug: XG4A-@@31
Wiring Diagram
Mounted Connector model: MIL Connector
A
(44.81)
50
Connector
Terminal Block
M3
3.5
7 (Pitch)
The label contents depend on
the number of poles.
5.8
19.7
Mounted Connector model: FCN Connector
(48.05)
① ②
⑲ ⑳
① ②
⑲ ⑳
Connector
① ②
① ②
⑲ ⑳
⑲ ⑳
Terminal Block
Label Contents
Note: The label contents for a Terminal Block with 34 poles are shown.
41
XW2R
Without power supply terminals
Slotted screw (rise up)
Ordering Information
Appearance∗
Mounted Connector model
MIL Connector
FCN Connector
Number of poles
Model
Dimension A (mm)
XG4A-2031
20
XW2R-E20GD-T
XG4A-3431
34
XW2R-E34GD-T
64.4
98.5
XG4A-4031
40
XW2R-E40GD-T
113.5
XG4A-5031
50
XW2R-E50GD-T
138.5
XG4A-6031
60
XW2R-E60GD-T
163.5
FCN-364P040-AU
40
XW2R-E40FD-T
113.5
* The mounted Connector shown in the appearance illustration is a MIL Connector.
Ratings and Specifications
Rated current
1A
Rated voltage
125 VAC, 24 VDC
Insuration resistance
100MΩ min. (at 500VDC)
Dielectric strength
500VAC for 1 min
(leakage current: 1 mA max.)
Applicable crimp
terminals
Applicable wires
TC-05
Dia. = 1
AWG22 to AWG18
(0.30 to 0.75 mm2)
TC-1.25S
Dia. = 1.5
AWG22 to AWG16
(0.30 to 1.25 mm2)
BT1.25-9-1
BT1.25-10-1
W = 2.2
AWG22 to AWG16
(0.30 to 1.25 mm2)
Rod
Blade
Ambient operating
temperature
Appli
cable
wires
Details on Crimp Terminals
0 to 55°C
Round rod
Dia.
8-10 mm
Blade
t = 0.75
8-10 mm
W
Note: Round rod and blade crimp terminals are made by Nichifu.
Applicable wire
sizes
AWG 22 to 16 (ferrules)
AWG 26 to 16 (stranded or solid wires)
Stripped length
7 mm
Tightening
0.5 to 0.6 N·m
Dimensions
(Unit: mm)
Mounted Connector model:MIL Connector
Drawing is MIL Plug: XG4A-@@31
A
Wiring Diagram
(44.81)
50
Connector
Terminal Block
The label contents depend on
the number of poles.
19.7
2.5
5 (Pitch)
(43)
Mounted Connector model:FCN Connector
① ②
⑲ ⑳
① ②
⑲ ⑳
① ②
① ②
Label Contents
Note: The label contents for a Terminal Block with 34 poles are shown.
42
Connector
⑲ ⑳
⑲ ⑳
Terminal Block
XW2R
Without power supply terminals
Push-in spring
Ordering Information
Appearance∗
Mounted Connector model
MIL Connector
FCN Connector
Number of poles
Model
Dimension A (mm)
XG4A-2031
20
XW2R-P20GD-T
64.4
XG4A-3431
34
XW2R-P34GD-T
98.5
XG4A-4031
40
XW2R-P40GD-T
113.5
XG4A-5031
50
XW2R-P50GD-T
138.5
XG4A-6031
60
XW2R-P60GD-T
163.5
FCN-364P040-AU
40
XW2R-P40FD-T
113.5
* The mounted Connector shown in the appearance illustration is a MIL Connector.
Ratings and Specifications
1A
Rated voltage
125 VAC, 24 VDC
Insuration resistance
100MΩ min. (at 500VDC)
Dielectric strength
500VAC for 1 min
(leakage current: 1 mA max.)
Ambient operating
temperature
0 to 55°C
Applicable
wires
Details on Crimp Terminals
Square ferrules
Applicable Ferrules
Rated current
B
• Use ferrules of the lengths and thicknesses
specified below.If other lengths or thicknesses
are used, connection maynot be possible or it
may not be possible to insert or remove the
posts.
8-10 mm
A
Round ferrules
Dia. C
8-10 mm
• Ferrule Dimensions
Applicable
wire sizes
AWG 24 to 14 (ferrules)
AWG 28 to 14 (stranded or solid)
(Outer diameter of insulation must be
4 mm max)
Stripped
length
AWG28-16: 8 to 10 mm
AWG14: 9 to 10 mm
Square
ferrules
Round
ferrules
Dimension A
(Width)
2.7 mm max.
Dimension B
(Height)
2 mm max.
Dimension C
(Diameter)
2 mm dia. max. (after crimping)
The cross-sectional area
after crimping must be
4.8 mm2 or less
Refer to page 46 for information on Square/Round ferrule and use tool.
Dimensions
(Unit: mm)
Drawing is MIL Plug: XG4A-@@31
Wiring Diagram
Mounted Connector model: MIL Connector
A
(44.81)
50
Connector
Terminal Block
19.7
5 (Pitch)
The label contents depend on
the number of poles.
Mounted Connector model: FCN Connector
(33.1)
① ②
⑲ ⑳
① ②
⑲ ⑳
① ②
⑲ ⑳
① ②
⑲ ⑳
Connector
Terminal Block
Label Contents
Note: The label contents for a Terminal Block with 34 poles are shown.
43
Common Terminals
XW2R-COM
Space-saving and less wiring work of
power supply wiring are achieved.
• Common wiring is already wired on the PCB, transition
wiring is unnecessary.
• Wiring is completed by one action.
• Models available with +,−,+ − Mix.
Application Example
Each terminal connected by PCB.
Bus-bar and transition wiring are unnecessary.
for ὺ
for ὼ
Connection Examples
PLC
Connection cable
(XW2Z)
Power supply
Connector terminal conversion unit
for signal
(XW2R-@34GD-C@)
Common Terminal
(XW2R-P40@D-COM)
Model list
X W 2 R - P 40 @ D - C O M
Wiring method
Terminal number of poles
P
40 40 poles
Push-in spring
Type of connector
P + Common
M
B
44
− Common
+ − Mix
Mounting method
D
DIN Track mounting
Power supply terminals
(Common terminals)
COM
Provided
XW2R
Ordering Information
Appearance
Specification
Number of poles
Model
+ Common terminal
XW2R-P40PD-COM
− Common terminal
40
XW2R-P40MD-COM
+ − Mix terminal
XW2R-P40BD-COM
Details on Crimp Terminals
Ratings and Specifications
Square ferrules
Applicable Ferrules
B
Rated current
10A(Unit total)
Rated voltage
125VDC/240VAC
Insuration resistance
100MΩmin. (at 500VDC)
• Use ferrules of the lengths and thicknesses
specified below.If other lengths or thicknesses
are used, connection maynot be possible or it
may not be possible to insert or remove the
posts.
0 to 55°C
• Ferrule Dimensions
Ambient operating
temperature
Applicable
wires
Applicable
wire sizes
Stripped
length
Ferrule:AWG24 to 14
(0.2mm2 to 2mm2)
Stranded or solid wire:AWG 28 to 14
(0.08mm2 to 2mm2)
(Outer diameter of insulation must be
4 mm max)
AWG28-16: 8 to 10 mm
AWG14: 9 to 10 mm
Square
ferrules
Round
ferrules
8-10 mm
A
Round ferrules
Dia. C
8-10 mm
Dimension A
(Width)
2.7 mm max.
Dimension B
(Height)
2 mm max.
Dimension C
(Diameter)
2 mm dia. max. (after crimping)
The cross-sectional area
after crimping must be
4.8 mm2 or less
Refer to page 46 for information on Square/Round ferrule and use tool.
Dimensions
64.4
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
(33.1)
50
The label contents
depend on the model.
19.7
Label Contents
Wiring Diagram
形XW2R-P40PD-COM
形XW2R-P40MD-COM
形XW2R-P40BD-COM
XW2R-P40PD-COM
XW2R-P40MD-COM
XW2R-P40BD-COM
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
Lower
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
Upper
+
+
+
+
+
+
+
+
+
+
Lower
−
−
−
−
−
−
−
−
−
−
1
2
3
4
5
6
7
8
9
10
Upper
Lower
Upper
1 2 3 4 5 6 7 8 9 10
45
XW2R
Safety Precautions
Precautions for Correct Use
Wiring Precautions
• Do not perform wiring work, remove connectors, or connect connectors while power is being supplied.
Electric shock or damage to the device may result.
• Double-check all wiring before turning ON the power supply.
• After wiring, route the cable so that force is not applied directly to the connections.
Wires for Terminal Blocks
• Do not damage the cores when stripping the insulation from them.
• Always twist stranded wires together before connecting them.
• Do not presolder wires. It may not be possible to connect them or remove them.
XW2R-P@@ type (Square/Round ferrule)
Type of terminal
Manufacturer
Size
AWG24
AI0.25-8@@
AWG22
AI0.34-8TQ
AWG20
AI0.5-10WH
AI0.5-8WH
AWG18
AI0.75-10GY
AI0.75-8GY
AWG16
AI1.5-10BK
AWG14
AI2.5-8BU
AWG24
H0.25/12
AWG22
H0.34/12
AWG20
H0.5/14
AWG18
H0.75/14
Phoenix Contact
Square ferrule
Weidmuller
Round ferrule
Nichifu
Recommend ferrule
Recommend crimp tool
CRIMFOX6
PZ6 roto
AWG16
H1.5/14
AWG14
H2.5/15D
AWG22AWG16
TGV TC-1.25-9T
NH11
NH32
NH65
Note: @@ of ferrule model is for color (Ex: YE = Yellow)
When an electric wire is connected directly (J,E,P type)
a
Model
Strip length “a”
XW2R-J@@
9 mm
XW2R-E@@
7 mm
XW2R-P@@
AWG28-16: 8 to 10 mm
AWG14: 9 to 10 mm
Mounting Units to and Removing Units from DIN Track
Mounting Procedure
Removal Procedure
2 Press.
1 Hook.
1. Hook the Unit on the DIN Track.
2. Press the Unit onto the DIN Track to secure it.
46
1. Insert a flat-blade screwdriver into the DIN Track lock.
2. Move the screwdriver like a lever to free the lock.
XW2R
Connecting Spring cramp Terminals
Using Ferrules
How to insert wire
How to release wire
Release hole
Terminal holes
The wire should be pushed into
the terminal block till stopping.
Insert the screwdriver into the
release hole and pull out the ferrule.
Using Stripped Wires
Inserting and Removing Wires
Insert the screwdriver into the release hole, and
the wire should be inserted into the wire insertion
hole, and then pull out the screwdriver.
Inserting Wires
Removing Wires
1. Press the a flat-blade screwdriver diagonally into the release hole.
Press at an angle of 10° to 15°.
If you press in the screwdriver correctly, you will feel the spring in
the release hole.
1. Press the flat-blade screwdriver diagonally into the release hole.
Press at an angle of 10° to 15°.
If you press in the screwdriver correctly, you will feel the spring in
the release hole.
Flat-blade screwdriver
Release hole
1
Flat-blade screwdriver
1
10 to 15˚
2. Leave the flat-blade screwdriver pressed into the release hole and
insert the stranded wire or the solid wire into the terminal hole.
Insert the stranded wire or the solid wire until the stripped portion
is no longer visible to prevent shorting.
10 to 15˚
2. Leave the flat-blade screwdriver pressed into the release hole and
pull out the wire.
2
2
Wire
Stranded wire/Solid wire
3. Remove the flat-blade screwdriver from the release hole.
3. Remove the flat-blade screwdriver from the release hole.
3
3
47
XW2R
Precautions for Safe Use
• Do not press the flat-blade screwdriver straight into the release hole. Doing so may break the terminal block.
• When you insert a flat-blade screwdriver into a release hole, press it down with a force of 30 N max. Applying excessive force may damage the
terminal block.
• Do not tilt or twist the flat-blade screwdriver while it is pressed into the release hole. Doing so may break the terminal block.
• Make sure that all wiring is correct.
• Do not bend the cable forcibly. Doing so may sever the cable.
Use tool
• Select a use tool from following table.
Model
Use tool
Specialized tool and dimension
XW2R-J@@
Phillips screwdriver
JIS#2
Flat-blade screwdriver
Model XW4Z-00B
Head of screwdriver Is 0.4 x 2.5mm max.
XW2R-E@@
XW2R-P@@
Flat-blade screwdriver
Model
XW4Z-00B
Bending Radius of Connecting Cables
• To prevent damaging the Connecting Cables, use the following minimum bending radii as guidelines.
X W 2Z - @ @ @ @ @
End of model number
Minimum bending radius
BF-L, EE-L, FF-L
66 mm
A
67.2 mm
EE
83 mm
B, D, K, L, N
88 mm
For checking electrical continuity
• XW2R-E@@ type: There is no elecrical continuity in the screw, Please confirm it at hole for confirming continuity or wiring part.
48
Shielded Cables for Connector-Terminal Block Conversion Units
XW2Z
Connect Connector-Terminal
Block Conversion Units (XW2@) to
I/O Units for Programmable
Controllers with one touch.
Shielded
Ratings and Specifications
Rated current
1A
Rated voltage
125 VAC 24 VDC
Contact resistance
20 mΩ max. (at 20 mV, 100 mA max.) *1
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
500 VAC for 1 min (leakage current: 1 mA max.) *2
Ambient operating
temperature
−25 to 80°C
*1 Contact resistance for the Connector.
*2 Dielectric strength for the Connector.
Materials and Finish
Item
Part name
Materials and Finish
Housing
XG4M-2030
XG4M-3430
XG4M-4030
Connectors
Fiber-glass reinforced PBT resin (UL94V-0)/black
Cover
Contacts
XG4T-2004/4004
FCN-367J024-AU/F *
FCN-367J040-AU/F *
Mating end
Phosphor bronze/nickel base, 0.15-μm gold plating
Press-fit end
Phosphor bronze/nickel base, 2.0-μm tin plating
Strain Relief
Fiber-glass reinforced PBT resin (UL94V-0)/black
Housing
Polyester resin (UL94V-0)/black
Contacts
Mating end
Copper alloy/gold plated
Press-fit end
Copper alloy/tin plated
Connecting screw
Steel/nickel plated
Cable
UL2464 Interface Cable
AWG28/Shielded
Crimp terminal
Forked crimp terminal
1.25 Y AS 3.5 or the equivalent
Note: These housings, contacts, and connecting screws are made by Fujitsu Component Ltd.
XW2Z-@@@A
Connectors: One 24-pin FCN Connector to One 20-pin MIL Connector
Appearance
Model
XW2Z-050A
XW2Z-100A
XW2Z-150A
XW2Z-200A
XW2Z-300A
XW2Z-500A
XW2Z-700A
XW2Z-010A
XW2Z-15MA
XW2Z-20MA
Cable length L (m)
0.5
1
1.5
2
3
5
7
10
15
20
Cable length L (m)
20
B1
19
Wiring Diagram
FCN367J024-AU/F
(Mating Side)
1
1
2
2
6
6
7
7
9
9
XG4M-2030-T
(Mating Side)
Triangle mark
2
1
4
3
12 11
14 13
18
17
10 10
11
20 19
11
12 12
NC
A1
B A
B12
A12
2
1
L
49
XW2Z
XW2Z-@@@AA
Connectors: One 14-pin MIL Connector to One 14-pin MIL Connector
Appearance
Model
XW2Z-050AA
XW2Z-100AA
XW2Z-200AA
XW2Z-500AA
XW2Z-010AA
Cable length L (m)
Cable length L (m)
0.5
1
2
5
10
2
14
13
2
1
Wiring Diagram
XG4M-1430-T
(Mating Side)
XG4M-1430-T
(Mating Side)
1
13
14
Note: Wire the pins 1:1 so that the
Connector pin numbers match.
L
XW2Z-@@@AU(for XW2D-20C6)
Connectors: One 24-pin FCN Connector to One 20-pin MIL Connector with Lock
Appearance
Model
XW2Z-050AU
XW2Z-100AU
XW2Z-150AU
XW2Z-200AU
XW2Z-300AU
XW2Z-500AU
Cable length L (m)
0.5
1
1.5
2
3
5
Cable length L (m)
20
B1
Wiring Diagram
FCN367J024-AU/F
(Mating Side)
1
1
2
2
6
6
7
7
9
9
XG4M-2030-U
(Mating Side)
Triangle mark
2
1
4
3
12 11
14 13
19
A1
18 17
10 10
B12
A12
20 19
11 11
2
1
12 12
L
NC
B A
XW2Z-@@@B
Connectors: One 40-pin FCN Connector to One 40-pin MIL Connector
Appearance
Model
XW2Z-050B
XW2Z-100B
XW2Z-150B
XW2Z-200B
XW2Z-300B
XW2Z-500B
XW2Z-700B
XW2Z-010B
XW2Z-15MB
XW2Z-20MB
XW2Z-050B-R1
XW2Z-100B-R1
XW2Z-150B-R1
XW2Z-200B-R1
XW2Z-300B-R1
XW2Z-500B-R1
Type
Normal wiring
Reversed wiring
Cable length L (m)
0.5
1
1.5
2
3
5
7
10
15
20
0.5
1
1.5
2
3
5
Wiring Diagram
Normal wiring
FCN367J040-AU/F
(Mating Side)
1
1
2
2
XG4M-4030-T
(Mating Side)
Triangle mark
2
1
4
3
10 10
20 19
11 11
22 21
19 19
38 37
20 20
40 39
B
A
Reversed wiring
FCN367J040-AU/F
(Mating Side)
Cable length L (m)
40
B1
A1
B20
A20
39
20 20
XG4M-4030-T
(Mating Side)
Triangle mark
2
1
4
3
19 19
2
1
L
11 11
20 19
10 10
22 21
2
2
1
1
38 37
40 39
A B
50
XW2Z
XW2Z-@@@BU (for XW2D-40C6)
Connectors: One 40-pin FCN Connector to One 40-pin MIL Connector with Lock
Appearance
Type
Normal wiring
Model
XW2Z-050BU
XW2Z-100BU
XW2Z-150BU
XW2Z-200BU
XW2Z-300BU
XW2Z-500BU
Cable length L (m)
Cable length L (m)
0.5
1
1.5
2
3
5
40
B1
Wiring Diagram
FCN367J040-AU/F
(Mating Side)
1
1
2
2
XG4M-4030-U
(Mating Side)
Triangle mark
2
1
4
3
10 10
39
A1
20 19
11 11
22 21
B20
A20
1
2
19 19
L
38 37
20 20
40 39
B A
XW2Z-@@@B-A(for XW2F-40G7-IN32)
Connectors: One 40-pin FCN Connector to One 40-pin MIL Connector
Appearance
Type
Normal wiring
Model
XW2Z-100B-A
XW2Z-150B-A
XW2Z-200B-A
XW2Z-300B-A
XW2Z-500B-A
Cable length L (m)
Cable length L (m)
1
1.5
2
3
5
40
B1
A1
B20
A20
39
1
2
L
Wiring Diagram
FCN367J040-AU/F
XG4M-4030-T
B20
B19
B18
B17
B16
B15
B14
B13
B12
B11
B10
B9
B8
B7
B6
B5
B4
B3
B2
B1
A20
A19
A18
A17
A16
A15
A14
A13
A12
A11
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
1
2
3
5
7
9
11
13
15
17
19
4
6
8
10
12
14
16
18
20
21
22
23
25
27
29
31
33
35
37
39
24
26
28
30
32
34
36
38
40
XW2Z-@@@B-B(for XW2F-40G7-OUT32)
Connectors: One 40-pin FCN Connector to One 40-pin MIL Connector
Appearance
Type
Normal wiring
Model
XW2Z-100B-B
XW2Z-150B-B
XW2Z-200B-B
XW2Z-300B-B
XW2Z-500B-B
Cable length L (m)
Cable length L (m)
1
1.5
2
3
5
40
B1
A1
B20
A20
2
L
39
1
Wiring Diagram
FCN367J040-AU/F
B20
B19
B18
B17
B16
B15
B14
B13
B12
B11
B10
B9
B8
B7
B6
B5
B4
B3
B2
B1
A20
A19
A18
A17
A16
A15
A14
A13
A12
A11
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
XG4M-4030-T
1
3
5
7
9
11
13
15
17
19
2
4
6
8
10
12
14
16
18
20
21
23
25
27
29
31
33
35
37
39
22
24
26
28
30
32
34
36
38
40
51
XW2Z
XW2Z-@@@D
Connectors: One 40-pin FCN Connector to Two 20-pin MIL Connectors
Wiring Diagram
Appearance
Cable
length L (m)
A
B
1
0.75
1.5
1.25
2
1.75
3
2.75
5
4.75
10
9.75
15 14.75
20 19.75
Model
XW2Z-100D
XW2Z-150D
XW2Z-200D
XW2Z-300D
XW2Z-500D
XW2Z-010D
XW2Z-15MD
XW2Z-20MD
Cable length L (m)
(250)
CN1
20
1
1
2
2
8
8
9
9
10
10
11
11
17
17
18
18
19
19
20
20
CN3
3
16
15
18
17
20
19
XG4M-2030-T
NC
CN3
(Mating Side)
NC
2
1
4
3
16
15
18
17
20
19
Triangle
mark
NC
CN2
1 20
19
2
1
B20
B19
B18
B17
B16
B15
B14
B13
B12
B11
B10
B9
B8
B7
B6
B5
B4
B3
B2
B1
XG4M-2030-T
CN3
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
XG4M-2030-T
CN2
BA
A1
2
B20
4
FCN367J040-AU/F
CN1
19
YELLOW
B1
XG4M-2030-T
CN2
(Mating Side)
Triangle mark
2
1
FCN367J040-AU/F
CN1
(Mating Side)
A20
BLACK
(500)
B
A
A20
A19
A18
A17
A16
A15
A14
A13
A12
A11
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
XW2Z-@@@EE
Connectors: One 34-pin MIL Connector to One 34-pin MIL Connector
Appearance
Wiring Diagram
Cable
length L (m)
0.5
1
1.5
2
3
5
Model
XW2Z-050EE
XW2Z-100EE
XW2Z-150EE
XW2Z-200EE
XW2Z-300EE
XW2Z-500EE
XG4M-3430-T
(Mating Side)
XG4M-3430-T
(Mating Side)
Triangle mark
Cable length L (m)
2
40
39
2
1
1
39
40
Triangle mark
L
Note: Wire the pins 1:1 so that the
Connector pin numbers match.
XW2Z-@@@F
Connectors: One 20-pin MIL Connector to 20 Loose Wires with Crimp Terminals Attached
Wiring Diagram
Appearance
Cable
length L (m)
1
1.5
2
3
5
10
15
20
Model
XW2Z-100F
XW2Z-150F
XW2Z-200F
XW2Z-300F
XW2Z-500F
XW2Z-010F
XW2Z-15MF
XW2Z-20MF
(Mating Side)
Triangle mark
Cable length L (m)
1
Forked crimp
terminals (M3.5)
2
Device end
19
20
L
300(mm)
52
Connector Pin No. Table
XG4M-2030-T
19
20
17
18
3
4
1
2
Forked crimp
terminals (M3.5)
20
19
18
17
4
3
2
1
Forked No. of
terminal cores
1
1
2
3
2
4
5
3
6
7
4
8
9
5
10
11
6
12
13
7
14
15
8
16
17
9
18
19
10
20
Insulation Dot
color
marks
Blue
Pink
Green
@
Orange
Gray
Blue
Pink
Green
Orange
Gray
@@
Dot
Connector
color pin No.
Red
1
Black
2
Red
3
Black
4
Red
5
Black
6
Red
7
Black
8
Red
9
Black
10
Red
11
Black
12
Red
13
Black
14
Red
15
Black
16
Red
17
Black
18
Red
19
Black
20
XW2Z
XW2Z-@@@H-1 (to connect CS1-series I/O Unit)
Connectors: One 56-pin FCN Connector to One 60-pin MIL Connector
Appearance
Type
Normal
wiring
Reversed
wiring
Model
XW2Z-050H-1
XW2Z-100H-1
XW2Z-150H-1
XW2Z-200H-1
XW2Z-300H-1
XW2Z-500H-1
XW2Z-700H-1
XW2Z-010H-1
XW2Z-100H-1G
XW2Z-150H-1G
XW2Z-200H-1G
XW2Z-300H-1G
XW2Z-500H-1G
Cable length L (m)
0.5
1
1.5
2
3
5
7
10
1
1.5
2
3
5
Cable length L (m)
60
B1
A1
B28
A28
59
1
2
L
* One or two Cables are used for each PLC I/O Unit.
Note: 1. The CS1 signals that are connected to the XW2B/D are different between the XW2Z-@@@H-@and XW2Z-@@@H-@G.
XW2Z-@@@H-2 (to connect CS1-series I/O Unit)
Connectors: One 56-pin FCN Connector to One 20-pin,One 40-pin MIL Connectors
Appearance
Type
Normal
wiring
Reversed
wiring
Cable length L (m)
A
B
Model
XW2Z-100H-2
XW2Z-150H-2
XW2Z-200H-2
XW2Z-300H-2
XW2Z-500H-2
XW2Z-010H-2
XW2Z-100H-2G
XW2Z-150H-2G
XW2Z-200H-2G
XW2Z-300H-2G
XW2Z-500H-2G
1
Cable length L (m)
0.75
1.5
1.25
2
1.75
3
2.75
5
4.75
10
9.75
1
0.75
1.5
1.25
2
1.75
3
2.75
5
4.75
(250)
CN3
20
19
2
1
Yellow
CN1
B1
B28
A1
CN2
40
39
2
1
A28
Black
(500)
B
A
Linear lengths (not including bends)
* One or two Cables are used for each PLC I/O Unit.
Note: 1. The CS1 signals that are connected to the XW2B/D are different between the XW2Z-@@@H-@and XW2Z-@@@H-@G.
XW2Z-@@@H-3 (to connect CS1-series I/O Unit)
Connectors: One 56-pin FCN Connector to Three 20-pin MIL Connectors
Appearance
Model
XW2Z-100H-3
XW2Z-150H-3
XW2Z-200H-3
XW2Z-300H-3
XW2Z-500H-3
XW2Z-010H-3
Cable length L (m)
B C Cable length L (m)
A
1
0.75
1.5
1.25
1.5
2
1.75
2
3
2.75
3
5
4.75
5
10
9.75
10
* One or two Cables are used for each PLC I/O Unit.
C
1
B
(500mm)
(250mm)
Gray
CN4
CN1
CN3
Yellow
CN2
Black
(500mm)
A
Linear lengths (not including bends)
53
XW2Z
I/O Signal Tables (Examples for CN1 on CS1W-OD291)
With XW2Z-@@@H-@ Cable Connected
XW2@-20G@
0
XW2Z-@@@H-3
1
1
2
3
3
5
7
6
9 11 13 15 17 19
1
1
2
3
3
5
N+1ch(CN3)
4 5 6 7 COM NC
0
9 11 13 15 17 19
1
7
2
3
N+2ch(CN4)
4 5 6 7 COM NC
3
5
7
2
4
8 10 12 14 16 18 20
2
4
8
9 10 11 12 13 14 15 +V NC
8
9 10 11 12 13 14 15 +V NC
8
9 10 11 12 13 14 15 +V NC
1
1
2
3
3
5
7
6
1
XW2@-20G@
N+1ch(CN2)
3 4 5 6 7 COM NC
0 1
2
9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
2
4
8
9 10 11 12 13 14 15 +V NC 8
1
8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
XW2B-60G@
9 10 11 12 13 14 15 +V NC
3
N+2ch(CN3)
4 5 6 7 COM NC
3
5
7
6
8 10 12 14 16 18 20
9 11 13 15 17 19
2
4
8
9 10 11 12 13 14 15 +V NC
0
1
2
3
1
3
5
7
9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59
2
4
8
9 10 11 12 13 14 15 +V
6
2
1
N+2ch(CN2)
3 4 5 6
8 10 12 14 16 18 20
Nch(CN2)
4 5 6 7 COM 0
1
N+1ch(CN2)
3 4 5 6 7 COM 0
2
6
9 11 13 15 17 19
8 10 12 14 16 18 20
Nch(CN2)
4 5 6 7 COM NC 0
6
1
4
0
XW2Z-@@@H-1
0
2
XW2@-40G@
XW2Z-@@@H-2
Nch(CN2)
4 5 6 7 COM NC
2
7 COM NC NC NC
8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60
8
9 10 11 12 13 14 15 +V
9 10 11 12 13 14 15 +V NC NC NC
8
With XW2Z-@@@H-@G/G79-@@@C-@@@-@@@ Cable Connected
XW2@-20G@
Nch(CN2)
+V NC 15 14 13 12 11 10
G79-@@@C-@@@@@@
1
3
5
2
4
7
6
9
9 11 13 15 17 19
6
5
4
3
2
1
XW2@-40G@
Nch(CN2)
+V NC 15 14 13 12 11 10
1
3
5
2
4
7
6
2
5
6
4
7
6
NC COM 7
4
7
6
9
5
4
3
2
1
9 11 13 15 17 19
6
6
5
4
3
2
1
5
4
3
3
2
0
5
4
7
6
NC COM 7
9
8
9 11 13 15 17 19
8 10 12 14 16 18 20
6
5
4
3
2
1
0
XW2@-20G@
9
2
N+1ch(CN2)
8 +V NC 15 14 13 12 11 10
9
1
8 10 12 14 16 18 20
NC COM 7
0 NC COM 7
N+2ch(CN4)
+V NC 15 14 13 12 11 10
8
N+2ch(CN3)
+V NC 15 14 13 12 11 10
8
9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
Nch(CN2)
+V NC 15 14 13 12 11 10
3
2
5
N+1ch(CN2)
8 +V NC 15 14 13 12 11 10
XW2B-60G@
1
0
3
9
1
8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
NC COM 7
XW2Z-@@@H-1G
1
8 10 12 14 16 18 20
NC COM 7
XW2Z-@@@H-2G
N+1ch(CN3)
+V NC 15 14 13 12 11 10
8
1
9
0
8
3
2
5
4
7
6
NC COM 7
9
8
9 11 13 15 17 19
8 10 12 14 16 18 20
6
5
4
N+2ch(CN2)
+V NC 15 14 13 12 11 10
3
9
2
1
0
8
9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59
8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60
6
5
4
3
2
1
0 NC COM 7
6
5
4
3
2
1
0 NC COM 7
6
5
4
3
2
1
0
Note: The XW2Z-@@@H-@G have the same I/O signal arrangement as the G79 I/O Relay Terminal Connecting Cables.
XW2Z-@@@K
Connectors: One 40-pin MIL Connector to One 40-pin MIL Connector
Appearance
Cable length L (m)
0.25
0.5
1
1.5
2
3
5
10
Model
XW2Z-C25K
XW2Z-C50K
XW2Z-100K
XW2Z-150K
XW2Z-200K
XW2Z-300K
XW2Z-500K
XW2Z-010K
Cable length L (m)
40
2
Wiring Diagram
XG4M-4030-T
(Mating Side)
XG4M-4030-T
(Mating Side)
Triangle mark
39 40
2
1
37 38
4
3
21 22
20 19
19
20
22
3
4
38 37
1
2
40 39
21
39
1
39
1
2
40
Triangle mark
Note: Wire the pins 1:1 so that the
Connector pin numbers match.
L
XW2Z-@@@L
Connectors: One 40-pin FCN Connector to Two 20-pin MIL Connectors
Appearance
Cable length L (m)
A
B
1
0.75
1.5
1.25
2
1.75
3
2.75
5
4.75
10
9.75
15
14.75
20
19.75
Model
XW2Z-100L
XW2Z-150L
XW2Z-200L
XW2Z-300L
XW2Z-500L
XW2Z-010L
XW2Z-15ML
XW2Z-20ML
CN3
CN1
20
19
2
1 20
Green
2
1
39
2
B
A
54
CN2
19
White
40
(500)
FCN367J040-AU/F
XG4M-2030-T
CN1
CN3
B20
B19
B18
B17
B16
B15
B14
B13
B12
B11
B10
B9
B8
B7
B6
B5
B4
B3
B2
B1
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
XG4M-2030-T
CN2
(250)
Cable length L (m)
Wiring Diagram
1
A20
A19
A18
A17
A16
A15
A14
A13
A12
A11
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
XW2Z
XW2Z-@@@N
Connectors: One 40-pin MIL Connector to Two 20-pin MIL Connector
Appearance
Cable length L (m)
A
B
1
0.75
1.5
1.25
2
1.75
3
2.75
5
4.75
10
9.75
15
14.75
20
19.75
Model
XW2Z-100N
XW2Z-150N
XW2Z-200N
XW2Z-300N
XW2Z-500N
XW2Z-010N
XW2Z-15MN
XW2Z-20MN
Wiring Diagram
XG4M-4030-T
(Mating Side)
39
40
37
38
23
24
21
22
19
20
Triangle mark
2
1
4
3
18
17
20
19
2
1
4
3
Triangle mark
17 18
(250)
Cable length L (m)
XG4M-2030-T
CN2
(Mating Side)
CN2
CN1
20
19
2
1 20
Green
2
1
CN3
19
3
4
1
2
18 17
20 19
39
Triangle mark
40
XG4M-2030-T
CN3
(Mating Side)
Black
2
1
(500)
B
A
Linear lengths (not including bends)
XW2Z-@@@PF (to connect XW2R-@34G@-C@ to OMRON PLC)
Connectors: One 40-pin FCN Connector to One 40-pin MIL Connector
Appearance
Cable length L (m)
0.5
1
1.5
2
3
5
Model
XW2Z-050PF
XW2Z-100PF
XW2Z-150PF
XW2Z-200PF
XW2Z-300PF
XW2Z-500PF
Wiring Diagram
FCN367J040-AU/F
(Mating Side)
1
1
2
2
10
Triangle mark
40
B1
A1
B20
A20
2
1
4
3
10
20 19
11 11
Cable length L (m)
XG4M-4030-T
(Mating Side)
22 21
39
19
19
38 37
20 20
2
40 39
1
L
B
A
XW2Z-@@@PM (to connect XW2R-@34G@-C@ to OMRON PLC)
Connectors: One 40-pin MIL Connector to One 40-pin MIL Connector
Appearance
Model
XW2Z-050PM
XW2Z-100PM
XW2Z-150PM
XW2Z-200PM
XW2Z-300PM
XW2Z-500PM
Cable length L (m)
Cable length L (m)
0.5
1
1.5
2
3
5
2
40
39
40
2
1
Wiring Diagram
XG4M-4030-T
(Mating Side)
XG4M-4030-T
(Mating Side)
Triangle mark
39
40
2
1
37
38
4
3
21 22
20 19
19
20
22
3
4
38
37
1
2
40
39
21
1
39
L
Triangle mark
Note: Wire the pins 1:1 so that the
Connector pin numbers match.
55
XW2Z
XW2Z-@@@X
Connectors: One 20-pin MIL Connector to One 20-pin MIL Connector
Appearance
Cable length L (m)
Wiring Diagram
Cable length L (m)
0.5
1
2
3
5
10
Model
XW2Z-C50X
XW2Z-100X
XW2Z-200X
XW2Z-300X
XW2Z-500X
XW2Z-010X
20
2
XG4M-2030-T
(Mating Side)
Triangle mark
20
2
1
17 18
4
3
3
4
18 17
1
2
20
19
19
1
19
2
20
XG4M-2030-T
(Mating Side)
19
Triangle mark
1
Note: Wire the pins 1:1 so that the
Connector pin numbers match.
L
Safety Precautions
Precautions for Correct Use
Wiring
• Do not perform wiring work, remove connectors, or connect connectors while power is being supplied. Electric shock or damage to the device
may result.
• Double-check all wiring before turning ON the power supply.
• After wiring, route the cable so that force is not applied directly to the connections.
Bending Radius of Connecting Cables
• To prevent damaging the Connecting Cables, use the following minimum bending radii as guidelines.
X W 2Z - @ @ @ @ @
End of model number Minimum bending radius
56
AA
60mm
A,AU,F,X
68mm
EE
83mm
B,BU,B-A,B-B,D,
K,L,N,PF,PM
88mm
H-1,H-2,H-3
99mm
Connecting Cables for I/O Terminal Blocks
XW2Z
Connect I/O Terminal Blocks (XW2@) to
I/O Units of Programmable Controllers.
Fast and Faultless.
Ratings and Specifications
Rated current
1A
Rated voltage
125 VAC 24 VDC
Contact resistance
20 mΩ max. (at 20 mV, 100 mA max.) *1
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
500 VAC for 1 min (leakage current: 1 mA max.) *2
Ambient operating
temperature
−25 to 80°C
*1 Contact resistance for the Connector.
*2 Dielectric strength for the Connector.
Materials and Finish
Item
Part name
MIL :
XG4M-2030
XG4M-4030
XG4M-6030
Connectors
XG4T-2004/4004/6004
Materials and Finish
Housing
Fiber-glass reinforced PBT resin (UL94V-0)/black
Cover
Contacts
Mating end
Phosphor bronze/nickel base, 0.15-μm gold plating
Press-fit end
Phosphor bronze/nickel base, 2.0-μm tin plating
Strain Relief
Fiber-glass reinforced PBT resin (UL94V-0)/black
Housing
FCN-367J024-AU/FW *
FCN-367J040-AU/FW
FCN-367J056-AU/FW
Contacts
Polyester resin (UL94V-0)/black
Mating end
Copper alloy/gold plated
Press-fit end
Copper alloy/tin plated
Connecting screw
Cable
UL2464 Interface Cable
Steel/nickel plated
AWG28 or the equivalent/AWG28 Non-shield
Note: These housings, contacts, and connecting screws are made by Fujitsu Component, Ltd.
57
XW2Z
XW2Z-@@@@AD-L
Connectors:One 24-pin FCN Connector to One 20-pin MIL Connector
Appearance
Wiring Diagram
Models
Cable length L (m)
XW2Z-0050AD-L
0.5
XW2Z-0100AD-L
1
XW2Z-0200AD-L
2
B1
XW2Z-0300AD-L
3
A2
Connector
No.
Wire pair
No.
A1
1
2
B2
A SIDE
20
B1
A3
B SIDE
3
B3
19
A4
A1
4
B4
A5
B12
2
A
1
A6
6
B6
S
I
D
E
L
5
B5
A12
A7
7
B7
A8
8
B8
A9
9
B9
A10
B10
A11
B11
A12
B12
10
11
12
Color of
insulator
Color of
dot
Connector
No.
White
-
1
White
Black
2
Black
-
3
Black
White
4
Yellow
-
5
Yellow
Gray
6
Red
-
7
8
Red
White
Purple
-
9
Purple
White
10
Pink
-
11
Pink
White
12
Orange
-
13
Orange
White
14
Brown
-
15
Brown
White
16
Green
-
17
Green
White
18
Light Green
-
19
Light Green
White
20
NC
-
NC
-
NC
-
NC
-
B
S
I
D
E
XW2Z-@@@@BH-L01
Connectors: One 40-pin FCN Connector to Two 20-pin MIL Connectors
Appearance
L1
XW2Z-0100BH-L01
1
CN 1 : FCN-367J040-AU/FW
L2
1.5
1.25
XW2Z-0200BH-L01
2
1.75
XW2Z-0300BH-L01
3
2.75
XW2Z-0400BH-L01
4
3.75
XW2Z-0500BH-L01
5
4.75
(250)
Color of insulator
0.75
XW2Z-0150BH-L01
CN1
Wiring Diagram
Cable length L (m)
Models
CN3
20
19
2
1 20
19
2
1
(YELLOW)
B1
B20
A1
CN2
White
Black
Yellow
Red
Purple
Pink
Orange
Brown
Green
Light Green
Gray
Blue
Light Blue
White
Black
Yellow
Red
Purple
NC
NC
Color of Connector
dot
No.
B1
Black
B2
White
B3
Gray
B4
White
B5
White
B6
White
White
B7
White
B8
White
B9
White
B10
White
B11
White
B12
White
B13
Red
B14
Orange
B15
Red
B16
Yellow
B17
Yellow
B18
B19
B20
A20
(500)
58
Color of
Connector
Color of insulator
dot
No.
White
Black
1
Light Green
2
White
Black
3
White
Gray
4
White
Yellow
5
Gray
Blue
6
White
Red
7
White
Light Blue
8
White
Purple
9
White
White
10
Red
Pink
11
White
Black
12
Orange
Orange
13
White
Yellow
14
Red
Brown
15
White
Red
16
Yellow
Green
17
White
Purple
18
Yellow
NC
19
NC
20
CN 2 : XG4M-2030-T
(BLACK)
L2
L1
CN 3 : XG4M-2030-T
Color of insulator
White
Black
Yellow
Red
Purple
Pink
Orange
Brown
Green
Light Green
Gray
Blue
Light Blue
White
Black
Yellow
Red
Purple
NC
NC
Color of Connector
dot
No.
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
Yellow
A14
Yellow
A15
Black
A16
Black
A17
Black
A18
A19
A20
Color of
Connector
Color of insulator
dot
No.
1
White
2
Light Green
3
Black
4
Gray
5
Yellow
6
Blue
7
Red
8
Light Blue
9
Purple
Yellow
10
White
11
Pink
Yellow
12
Black
13
Orange
Black
14
Yellow
15
Brown
Black
16
Red
17
Green
Black
18
Purple
19
NC
20
NC
XW2Z
XW2Z-@@@@BH-L02
Connectors: One 40-pin FCN Connector to Two 20-pin MIL Connectors
Appearance
Wiring Diagram
Cable length L (m)
Models
XW2Z-0100BH-L02
L2
1
0.75
XW2Z-0150BH-L02
1.5
1.25
XW2Z-0200BH-L02
2
1.75
XW2Z-0300BH-L02
3
2.75
XW2Z-0400BH-L02
4
3.75
XW2Z-0500BH-L02
5
4.75
Color of insulator
(250)
CN2
CN1
(BLACK)
B1
B20
CN 3 : XG4M-2030-T
CN 1 : FCN-367J040-AU/FW
L1
20
19
2
1 20
19
2
1
A1
CN3
White
Black
Yellow
Red
Purple
Pink
Orange
Brown
Green
Light Green
Gray
Blue
Light Blue
White
Black
Yellow
Red
Purple
Pink
Orange
Color of
Connector
Color of insulator
dot
No.
20
White
Black
White
19
Gray
White
18
Black
White
17
Blue
Gray
16
Yellow
White
15
Light Blue
White
14
Red
13
Red
White
12
White
Purple
11
Orange
Black
10
White
Pink
9
Red
Yellow
8
White
Orange
7
Yellow
Red
6
White
Brown
5
Yellow
Purple
4
White
Green
3
Yellow
Pink
2
Light Green
White
1
Yellow
Orange
Color of Connector
dot
No.
B1
Black
B2
White
B3
Gray
B4
White
B5
White
B6
White
White
B7
White
B8
White
B9
White
B10
White
B11
White
B12
White
B13
Red
B14
Orange
B15
Red
B16
Yellow
B17
Yellow
B18
Yellow
B19
Yellow
B20
A20
CN 2 : XG4M-2030-T
(YELLOW)
L2
L1
(500)
Color of insulator
White
Black
Yellow
Red
Purple
Pink
Orange
Brown
Green
Light Green
Gray
Blue
Light Blue
White
Black
Yellow
Red
Purple
Pink
Orange
Color of Connector
dot
No.
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
Yellow
A14
Yellow
A15
Black
A16
Black
A17
A18
Black
Black
A19
Black
A20
Color of
Connector
Color of insulator
dot
No.
20
White
19
Gray
18
Black
17
Blue
16
Yellow
15
Light Blue
14
Red
Yellow
13
White
12
Purple
Yellow
11
Black
10
Pink
Black
9
Yellow
8
Orange
Black
7
Red
6
Brown
Black
5
Purple
4
Green
Black
3
Pink
2
Light Green
Black
1
Orange
XW2Z-@@@@BF-L
Connectors: One 40-pin FCN Connector to One 40-pin MIL Connector
Appearance
Wiring Diagram
Models
Cable length L (m)
XW2Z-0050BF-L
0.5
XW2Z-0100BF-L
1
XW2Z-0150BF-L
1.5
XW2Z-0200BF-L
2
A3
XW2Z-0300BF-L
3
A4
XW2Z-0500BF-L
5
XW2Z-0700BF-L
7
B5
XW2Z-1000BF-L
10
B6
Connector No.
A1
B1
A2
B2
B3
B4
A5
A6
A7
B7
A8
A SIDE
B SIDE
B8
A9
40
B1
B20
39
A1
A
S
I
D
E
A20
2
1
B9
A10
B10
A11
B11
A12
B12
L
A13
B13
A14
B14
A15
B15
A16
B16
A17
B17
A18
B18
A19
B19
A20
B20
Wire pair No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Color of insulator
Color of dot
White
-
White
Black
Black
-
Black
White
Yellow
-
Yellow
Gray
Red
-
Red
White
Purple
-
Purple
White
Pink
-
Pink
White
Orange
-
Orange
White
Brown
-
Brown
White
Green
-
Green
White
Light Green
-
Light Green
White
Gray
-
Gray
White
Blue
-
Blue
White
Light Blue
-
Light Blue
White
White
Yellow
White
Red
Black
Yellow
Black
Orange
Yellow
Black
Yellow
Red
Red
Black
Red
Yellow
Purple
Black
Purple
Yellow
Pink
Black
Pink
Yellow
Orange
Black
Orange
Yellow
Connector No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
B
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
S
I
D
E
59
XW2Z
XW2Z-@@@@CJ-L01
Connectors: One 56-pin FCN Connector to Three 20-pin MIL Connectors
Appearance
Models
L1
L2
XW2Z-0150CJ-L01
1.5
1.25
XW2Z-0200CJ-L01
2
1.75
XW2Z-0300CJ-L01
3
2.75
A1
B28
A28
20
19
2
1
(GRAY)
CN1
CN3
20
19
(YELLOW)
2
CN2
1 20
19
2
1
(BLACK)
(500)
L2
L1
Color of
insulator
White
Black
Yellow
Red
Purple
Pink
Orange
Brown
Green
Light Green
Gray
Blue
Light Blue
White
Black
Yellow
Red
Purple
Pink
Orange
Brown
Green
Light Green
Gray
Blue
Light Blue
White
NC
Color of
dot
Black
White
Gray
White
White
White
White
White
White
White
White
White
White
Red
Orange
Red
Yellow
Yellow
Yellow
Yellow
Yellow
Orange
Yellow
Yellow
Yellow
Yellow
Pink
Connector
No.
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16
B17
B18
B19
B20
B21
B22
B23
B24
B25
B26
B27
B28
Color of
insulator
White
Black
Yellow
Red
Purple
Pink
Orange
Brown
Green
Light Green
Gray
Blue
Light Blue
White
Black
Yellow
Red
Purple
Pink
Orange
Brown
Green
Light Green
Gray
Blue
Light Blue
White
Color of
dot
Yellow
Yellow
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Purple
Connector
No.
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
A21
A22
A23
A24
A25
A26
A27
A28
NC
60
CN4 : XG4M-2030-T
CN 1 : FCN-367J056-AU/FW
CN4
(500)
B1
Wiring Diagram
Cable length L (m)
Connector
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Color of
insulator
Pink
Pink
Orange
Orange
Brown
Brown
Green
Green
Light Green
Light Green
Gray
Gray
Blue
Blue
Light Blue
Light Blue
White
White
NC
NC
Color of
dot
Black
Yellow
Black
Yellow
Black
Yellow
Black
Orange
Black
Yellow
Black
Yellow
Black
Yellow
Black
Yellow
Purple
Pink
CN 3 : XG4M-2030-T
Connector
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Color of
insulator
Light Green
Light Green
Gray
Gray
Blue
Blue
Light Blue
Light Blue
White
White
Black
Black
Yellow
Yellow
Red
Red
Purple
Purple
NC
NC
Color of
dot
White
White
White
White
Yellow
Red
Yellow
Orange
Black
Red
Black
Yellow
Black
Yellow
CN 2 : XG4M-2030-T
Connector
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Color of
insulator
White
White
Black
Black
Yellow
Yellow
Red
Red
Purple
Purple
Pink
Pink
Orange
Orange
Brown
Brown
Green
Green
NC
NC
Color of
dot
Black
White
Gray
White
White
White
White
White
White
XW2Z
XW2Z-@@@@CJ-L02
Connectors: One 56-pin FCN Connector to Three 20-pin MIL Connectors
Appearance
Wiring Diagram
Cable length L (m)
Models
L1
L2
L3
XW2Z-0150CJ-L02
1.5
1.25
1
XW2Z-0200CJ-L02
2
1.75
1.5
XW2Z-0300CJ-L02
3
2.75
2.5
L1
(750)
CN 1 : FCN-367J056-AU/FW
20
19
2
1
(GRAY)
CN1
B1
(500)
A1
20
19
CN3
(YELLOW)
B28
A28
2
20
19
2
1
(BLACK)
(250)
L3
L2
1
CN2
CN4
Color of
Color of Connector
insulator
dot
No.
White
Black
B1
Black
White
B2
Yellow
Gray
B3
Red
White
B4
Purple
White
B5
Pink
White
B6
Orange
White
B7
Brown
White
B8
Green
White
B9
Light Green
White
B10
Gray
White
B11
Blue
White
B12
Light Blue
White
B13
White
Red
B14
Black
Orange
B15
Yellow
Red
B16
Red
Yellow
B17
Purple
Yellow
B18
Pink
Yellow
B19
Orange
Yellow
B20
Brown
Yellow
B21
Green
Orange
B22
Light Green
Yellow
B23
Gray
Yellow
B24
Blue
Yellow
B25
Light Blue
Yellow
B26
White
Pink
B27
NC
B28
Color of
insulator
White
Black
Yellow
Red
Purple
Pink
Orange
Brown
Green
Light Green
Gray
Blue
Light Blue
White
Black
Yellow
Red
Purple
Pink
Orange
Brown
Green
Light Green
Gray
Blue
Light Blue
White
Color of Connector
dot
No.
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
A14
Yellow
A15
Yellow
A16
Black
A17
Black
A18
Black
A19
Black
A20
Black
A21
Black
A22
Black
A23
Black
A24
Black
A25
Black
A26
Black
A27
Purple
A28
NC
CN4 : XG4M-2030-T
Connector
No.
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Color of
Color of
insulator
dot
Pink
Black
Pink
Yellow
Orange
Black
Orange
Yellow
Brown
Black
Brown
Yellow
Green
Black
Green
Orange
Light Green
Black
Light Green Yellow
Gray
Black
Gray
Yellow
Blue
Black
Blue
Yellow
Light Blue
Black
Light Blue
Yellow
White
Purple
NC
NC
White
Pink
CN 3 : XG4M-2030-T
Connector
No.
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Color of
Color of
insulator
dot
Light Green
Light Green White
Gray
Gray
White
Blue
Blue
White
Light Blue
Light Blue
White
White
Yellow
White
Red
Black
Yellow
Black
Orange
Yellow
Black
Yellow
Red
Red
Black
Red
Yellow
Purple
Black
NC
NC
Purple
Yellow
CN 2 : XG4M-2030-T
Connector
No.
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Color of
Color of
insulator
dot
White
White
Black
Black
Black
White
Yellow
Yellow
Gray
Red
Red
White
Purple
Purple
White
Pink
Pink
White
Orange
Orange
White
Brown
Brown
White
Green
NC
NC
Green
White
61
XW2Z
XW2Z-@@@@CK-L0@
Connectors: One 56-pin FCN Connector to One 40-pin MIL Connector,
plus One 20-pin MIL Connector
Appearance
Cable length L (m)
Models
L1
L2
XW2Z-0150CK-L01
1.5
1.25
XW2Z-0150CK-L02
1.5
1.25
XW2Z-0200CK-L01
2
1.75
XW2Z-0200CK-L02
2
1.75
(250)
CN3
20
19
2
1
(YELLOW)
CN1
B1
B28
A1
CN2
40
39
2
1
A28
(BLACK)
L2
L1
(500)
Wiring Diagram
Wiring Diagram
XW2Z-0150CK-L01, XW2Z-0200CK-L01
CN 1 : FCN-367J056-AU/FW
Color of insulator Color of dot Connector No.
White
B1
Black
Black
B2
White
Yellow
B3
Gray
Red
B4
White
Purple
B5
White
Pink
B6
White
Orange
B7
White
Brown
B8
White
Green
B9
White
Light Green
B10
White
Gray
B11
White
Blue
B12
White
Light Blue
B13
White
White
B14
Red
Black
B15
Orange
Yellow
B16
Red
Red
B17
Yellow
Purple
B18
Yellow
Pink
B19
Yellow
Orange
B20
Yellow
Brown
B21
Yellow
Green
B22
Orange
Light Green
B23
Yellow
Gray
B24
Yellow
Blue
B25
Yellow
Light Blue
B26
Yellow
White
B27
Pink
B28
NC
Color of insulator Color of dot Connector No.
White
A1
Black
A2
Yellow
A3
Red
A4
Purple
A5
Pink
A6
Orange
A7
Brown
A8
Green
A9
Light Green
A10
Gray
A11
Blue
A12
Light Blue
A13
White
A14
Yellow
Black
A15
Yellow
Yellow
A16
Black
Red
A17
Black
Purple
A18
Black
Pink
A19
Black
Orange
A20
Black
Brown
A21
Black
Green
A22
Black
Light Green
A23
Black
Gray
A24
Black
Blue
A25
Black
Light Blue
A26
Black
White
A27
Purple
A28
NC
62
CN3 : XG4M-2030-T
Connector No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Color of insulator Color of dot
Pink
Black
Pink
Yellow
Orange
Black
Orange
Yellow
Brown
Black
Brown
Yellow
Green
Black
Green
Orange
Light Green
Black
Light Green Yellow
Gray
Black
Gray
Yellow
Blue
Black
Blue
Yellow
Light Blue
Black
Light Blue
Yellow
White
Purple
White
Pink
NC
NC
CN2 : XG4M-4030-T
Connector No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
Color of insulator Color of dot
White
Black
White
Black
Black
White
Yellow
Yellow
Gray
Red
Red
White
Purple
Purple
White
Pink
Pink
White
Orange
Orange
White
Brown
Brown
White
Green
Green
White
NC
NC
Light Green
Light Green White
Gray
Gray
White
Blue
Blue
White
Light Blue
Light Blue
White
White
Yellow
White
Red
Black
Yellow
Black
Orange
Yellow
Black
Yellow
Red
Red
Black
Red
Yellow
Purple
Black
Purple
Yellow
NC
NC
XW2Z-0150CK-L02, XW2Z-0200CK-L02
CN 1 : FCN-367J056-AU/FW
Color of insulator Color of dot Connector No.
White
B1
Black
Black
B2
White
Yellow
B3
Gray
Red
B4
White
Purple
B5
White
Pink
B6
White
Orange
B7
White
Brown
B8
White
Green
B9
White
Light Green
B10
White
Gray
B11
White
Blue
B12
White
Light Blue
B13
White
White
B14
Red
Black
B15
Orange
Yellow
B16
Red
Red
B17
Yellow
Purple
B18
Yellow
Pink
B19
Yellow
Orange
B20
Yellow
Brown
B21
Yellow
Green
B22
Orange
Light Green
B23
Yellow
Gray
B24
Yellow
Blue
B25
Yellow
Light Blue
B26
Yellow
White
B27
Pink
B28
NC
Color of insulator Color of dot Connector No.
White
A1
Black
A2
Yellow
A3
Red
A4
Purple
A5
Pink
A6
Orange
A7
Brown
A8
Green
A9
Light Green
A10
Gray
A11
Blue
A12
Light Blue
A13
White
A14
Yellow
Black
A15
Yellow
Yellow
A16
Black
Red
A17
Black
Purple
A18
Black
Pink
A19
Black
Orange
A20
Black
Brown
A21
Black
Green
A22
Black
Light Green
A23
Black
Gray
A24
Black
Blue
A25
Black
Light Blue
A26
Black
White
A27
Purple
A28
NC
CN3 : XG4M-2030-T
Connector No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Color of insulator Color of dot
Pink
White
NC
NC
Purple
White
Yellow
Light Blue
Black
Light Blue
Yellow
Blue
Black
Blue
Yellow
Gray
Black
Gray
Light Green Yellow
Black
Light Green
Orange
Green
Black
Green
Yellow
Brown
Black
Brown
Yellow
Orange
Black
Orange
Yellow
Pink
Black
Pink
CN2 : XG4M-4030-T
Connector No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
Color of insulator Color of dot
White
Green
NC
NC
Green
Brown
White
Brown
Orange
White
Orange
Pink
White
Pink
Purple
White
Purple
Red
White
Red
Yellow
Gray
Yellow
Black
White
Black
White
Black
White
Purple
Yellow
NC
NC
Purple
Black
Red
Yellow
Red
Black
Yellow
Red
Yellow
Black
Black
Orange
Black
Yellow
White
Red
White
Yellow
Light Blue
White
Light Blue
Blue
White
Blue
Gray
White
Gray
Light Green
White
Light Green
-
XW2Z
XW2Z-@@@@CG-L
Connectors: One 56-pin FCN Connector to One 60-pin MIL Connector
Appearance
Models
Cable length L (m)
XW2Z-0100CG-L
1
XW2Z-0200CG-L
2
XW2Z-0300CG-L
3
Wiring Diagram
Connector No.
A1
B1
Cable core No.
1
A2
2
B2
A3
3
B3
A SIDE
60
B1
A4
B SIDE
4
B4
A5
59
A1
5
B5
A6
6
B6
A7
B28
7
B7
A28
1
2
A8
8
B8
L
A9
9
B9
A10
10
B10
A11
11
B11
A12
12
B12
A13
13
B13
A14
A
S
I
D
E
14
B14
A15
15
B15
A16
16
B16
A17
17
B17
A18
18
B18
A19
19
B19
A20
20
B20
A21
21
B21
A22
22
B22
A23
23
B23
A24
24
B24
A25
25
B25
A26
26
B26
A27
27
B27
A28
Color of insulator
White
White
Black
-
Black
White
Yellow
-
Yellow
Gray
Red
-
Red
White
Purple
-
Purple
White
Pink
-
Pink
White
Orange
-
Orange
White
Brown
-
Brown
White
Green
-
Green
White
Light Green
-
Light Green
White
Gray
-
Gray
White
Blue
-
Blue
White
Light Blue
-
Light Blue
White
White
−
Red
Black
Yellow
Black
Orange
Yellow
Black
Yellow
Red
Red
Black
Red
−
Black
Yellow
Pink
Black
Pink
Yellow
Orange
Black
Orange
Yellow
Brown
Black
Brown
Yellow
Green
Black
Green
Orange
Light Green
Black
Light Green
Yellow
Gray
Black
Gray
Yellow
Blue
Black
Blue
Yellow
Light Blue
Black
Light Blue
Yellow
White
Purple
White
Pink
NC
NC
NC
NC
NC
30
−
Yellow
Purple
Purple
29
−
Yellow
White
28
B28
Color of dot
Black
NC
Connector No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
B
S
I
D
E
XW2Z-@@@@DD-L
Connectors: One 20-pin MIL Connector to One 20-pin MIL Connector
Appearance
Models
Cable length L (m)
XW2Z-0050DD-L
0.5
XW2Z-0100DD-L
1
XW2Z-0200DD-L
2
A SIDE
B SIDE
20
2
Wiring Diagram
Connector No.
A
19
1
S
I
D
E
19
2
20
L
1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Wire pair No.
1
2
3
4
5
6
7
8
9
10
Color of insulator
Color of dot
White
White
Black
Black
Yellow
Yellow
Red
Red
Purple
Purple
Pink
Pink
Orange
Orange
Brown
Brown
Green
Green
Light Green
Light Green
Black
White
Gray
White
White
White
White
White
White
White
Connector No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
B
S
I
D
E
63
XW2Z
XW2Z-@@@@EE-L
Connectors: One 34-pin MIL Connector to One 34-pin MIL Connector
Appearance
Model
Cable length L (m)
XW2Z-0050EE-L
0.5
XW2Z-0100EE-L
1
XW2Z-0150EE-L
1.5
XW2Z-0200EE-L
2
XW2Z-0300EE-L
3
XW2Z-0500EE-L
5
XW2Z-0700EE-L
7
XW2Z-1000EE-L
10
A SIDE
Connector No.
B SIDE
A
33
34
2
Wiring Diagram
1
S
I
D
E
33
1
2
34
L
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
14
25
26
27
28
29
30
31
32
33
34
Wire pair No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Color of insulator
White
White
Color of dot
Black
Black
-
Black
White
Yellow
-
Yellow
Gray
Red
-
Red
White
Purple
-
Purple
White
Pink
-
Pink
White
Orange
-
Orange
White
Brown
-
Brown
White
Green
-
Green
White
Light Green
-
Light Green
White
Gray
-
Gray
White
Blue
-
Blue
White
Light Blue
-
Light Blue
White
White
Yellow
White
Red
Black
Yellow
Black
Orange
Yellow
Black
Yellow
Red
Red
Black
Red
Yellow
Connector No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
B
15
16
S
17
I
18
D
19
E
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
XW2Z-@@@@FH-L01
Connectors: One 40-pin MIL Connector to Two 20-pin MIL Connectors
Appearance
Cable length L (m)
Models
L1
L2
XW2Z-0075FH-L01
0.75
0.5
XW2Z-0100FH-L01
1
0.75
XW2Z-0200FH-L01
2
1.75
XW2Z-0300FH-L01
3
2.75
XW2Z-0500FH-L01
5
4.75
CN 1 : XG4M-4030-T
(250)
CN3
CN1
20
19
2
1 20
(YELLOW)
2
1
39
CN2
19
CN2 : XG4M-2030-T
Color of insulator Color of dot
Orange
Yellow
Orange
Black
Pink
Yellow
Pink
Black
Purple
Yellow
Purple
Black
Red
Yellow
Red
Black
Yellow
Red
Yellow
Black
Black
Orange
Black
Yellow
White
Red
White
Yellow
Light Blue
White
Light Blue
Blue
White
Blue
Gray
White
Gray
-
Connector No.
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
Color of insulator Color of dot
Light Green
White
Light Green
Green
White
Green
Brown
White
Brown
Orange
White
Orange
Pink
White
Pink
Purple
White
Purple
Red
White
Red
Yellow
Gray
Yellow
Black
White
Black
White
Black
White
-
Connector No.
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Connector No. Color of insulator Color of dot
1
Orange
Yellow
2
Orange
Black
3
Pink
Yellow
4
Pink
Black
5
Purple
Yellow
6
Purple
Black
7
Red
Yellow
8
Red
Black
9
Yellow
Red
10
Yellow
Black
11
Black
Orange
12
Black
Yellow
13
White
Red
14
White
Yellow
15
Light Blue
White
16
Light Blue
17
Blue
White
18
Blue
19
Gray
White
20
Gray
-
(BLACK)
40
2
L2
L1
64
Wiring Diagram
(500)
CN 3 : XG4M-2030-T
1
Connector No. Color of insulator Color of dot
1
Light Green
White
2
Light Green
3
Green
White
4
Green
5
Brown
White
6
Brown
7
Orange
White
8
Orange
9
Pink
White
10
Pink
11
Purple
White
12
Purple
13
Red
White
14
Red
15
Yellow
Gray
16
Yellow
17
Black
White
18
Black
19
White
Black
20
White
-
XW2Z
XW2Z-@@@@FH-L02
Connectors: One 40-pin MIL Connector to Two 20-pin MIL Connectors
Appearance
Cable length L (m)
Models
L2
XW2Z-0075FH-L02
0.75
0.5
XW2Z-0100FH-L02
1
0.75
XW2Z-0200FH-L02
2
1.75
XW2Z-0300FH-L02
3
2.75
XW2Z-0500FH-L02
5
4.75
(250)
CN2
CN1
20
19
2
1 20
(BLACK)
2
1
39
40
Wiring Diagram
CN 1 : XG4M-4030-T
L1
CN3
19
CN2 : XG4M-2030-T
Color of insulator Color of dot
Orange
Yellow
Orange
Black
Pink
Yellow
Pink
Black
Purple
Yellow
Purple
Black
Red
Yellow
Red
Black
Yellow
Red
Yellow
Black
Black
Orange
Black
Yellow
White
Red
White
Yellow
Light Blue
White
Light Blue
Blue
White
Blue
Gray
White
Gray
-
Connector No.
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
Color of insulator Color of dot
Light Green
White
Light Green
Green
White
Green
Brown
White
Brown
Orange
White
Orange
Pink
White
Pink
Purple
White
Purple
Red
White
Red
Yellow
Gray
Yellow
Black
White
Black
White
Black
White
-
Connector No.
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Connector No. Color of insulator Color of dot
Orange
Yellow
20
Orange
Black
19
Pink
Yellow
18
Pink
Black
17
Purple
Yellow
16
Purple
Black
15
Red
Yellow
14
Red
Black
13
Yellow
Red
12
Yellow
Black
11
Black
Orange
10
Black
Yellow
9
White
Red
8
White
Yellow
7
Light Blue
White
6
Light Blue
5
Blue
White
4
Blue
3
Gray
White
2
Gray
1
(YELLOW)
2
CN 3 : XG4M-2030-T
1
(500)
L2
L1
Connector No. Color of insulator Color of dot
Light Green
White
20
Light Green
19
Green
White
18
Green
17
Brown
White
16
Brown
15
Orange
White
14
Orange
13
Pink
White
12
Pink
11
Purple
White
10
Purple
9
Red
White
8
Red
7
Yellow
Gray
6
Yellow
5
Black
White
4
Black
3
White
Black
2
White
1
XW2Z-@@@@FF-L
Connectors: One 40-pin MIL Connector to One 40-pin MIL Connector
Appearance
Models
Cable length L (m)
XW2Z-0030FF-L
0.3
XW2Z-0050FF-L
0.5
XW2Z-0100FF-L
1
XW2Z-0150FF-L
1.5
XW2Z-0200FF-L
2
XW2Z-0300FF-L
3
XW2Z-0500FF-L
5
XW2Z-0700FF-L
7
XW2Z-1000FF-L
10
A SIDE
Wiring Diagram
Connector No.
B SIDE
40
2
39
1
A
S
I
D
E
39
2
40
L
1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
Wire pair No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Color of insulator
White
White
Color of dot
Black
Black
-
Black
White
Yellow
-
Yellow
Gray
Red
-
Red
White
Purple
-
Purple
White
Pink
-
Pink
White
Orange
-
Orange
White
Brown
-
Brown
White
Green
-
Green
White
Light Green
-
Light Green
White
Gray
-
Gray
White
Blue
-
Blue
White
Light Blue
-
Light Blue
White
White
Yellow
White
Red
Black
Yellow
Black
Orange
Yellow
Black
Yellow
Red
Red
Black
Red
Yellow
Purple
Black
Purple
Yellow
Pink
Black
Pink
Yellow
Orange
Black
Orange
Yellow
Connector No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
B
18
19
S
20
I
21
D
22
E
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
65
XW2Z
Safety Precautions
Precautions for Correct Use
● Bending Radius of Connecting Cables
• To prevent damaging the Connecting Cables, use the following minimum bending radii as guidelines.
XW2Z-@@@@@@-@@@
End of model number
AD-L
DD-L
Minimum bending radius
54mm
BH-L01, BH-L02
BF-L
EE-L
66mm
FH-L01, FH-L02
FF-L
CJ-L01, CJ-L02
CK-L01, CK-L02
CG-L
66
80mm
XW2R
Vertical Screw Mounting
Type
Connected PLC
manufacturer
Wiring method
Mounted connector type
and model
Number of
poles
Model
Dimension A
Dimension B
Reference di- Refermensions dience
agram,
wiring
pattern 1
diagram
PLC connection
OMRON
Phillips screws
MIL
XG4A-4031
34
(XW2R-J34GV-C1)
130.7
122.2
1
PLC connection
OMRON
Phillips screws
MIL
XG4A-4031
34
(XW2R-J34GV-C2)
130.7
122.2
1
Page 20
PLC connection
OMRON
Phillips screws
MIL
XG4A-4031
34
(XW2R-J34GV-C3)
130.7
122.2
1
Page 20
PLC connection
OMRON
Phillips screws
MIL
XG4A-4031
34
(XW2R-J34GV-C4)
130.7
122.2
1
Page 20
PLC connection
OMRON
Slotted screws
MIL
XG4A-4031
34
(XW2R-E34GV-C1)
98.5
90
2
Page 21
PLC connection
OMRON
Slotted screws
MIL
XG4A-4031
34
(XW2R-E34GV-C2)
98.5
90
2
Page 21
PLC connection
OMRON
Slotted screws
MIL
XG4A-4031
34
(XW2R-E34GV-C3)
98.5
90
2
Page 21
PLC connection
OMRON
Slotted screws
MIL
XG4A-4031
34
(XW2R-E34GV-C4)
98.5
90
2
Page 21
PLC connection
OMRON
Push-in spring
MIL
XG4A-4031
34
(XW2R-P34GV-C1)
98.5
90
3
Page 22
PLC connection
OMRON
Push-in spring
MIL
XG4A-4031
34
(XW2R-P34GV-C2)
98.5
90
3
Page 22
PLC connection
OMRON
Push-in spring
MIL
XG4A-4031
34
(XW2R-P34GV-C3)
98.5
90
3
Page 22
PLC connection
OMRON
Push-in spring
MIL
XG4A-4031
34
(XW2R-P34GV-C4)
98.5
90
3
Page 22
PLC connection
OMRON
Push-in spring
MIL
XG4A-2031
16
(XW2R-P16GV-C1-COM)
98.5
90
4
Page 16
PLC connection
OMRON
Push-in spring
MIL
XG4A-2031
16
(XW2R-P16GV-C3-COM)
98.5
90
4
Page 16
PLC connection
OMRON
Push-in spring
MIL
XG4A-4031
32
(XW2R-P32GV-C1-COM)
186.7
178.2
4
Page 16
PLC connection
OMRON
Push-in spring
MIL
XG4A-4031
32
(XW2R-P32GV-C2-COM)
186.7
178.2
4
Page 16
PLC connection
OMRON
Push-in spring
MIL
XG4A-4031
32
(XW2R-P32GV-C3-COM)
186.7
178.2
4
Page 16
PLC connection
OMRON
Push-in spring
MIL
XG4A-4031
32
(XW2R-P32GV-C4-COM)
186.7
178.2
4
Page 16
PLC connection
Mitsubishi
Phillips screws
MIL
XG4A-4031
34
(XW2R-J34GV-M1)
130.7
122.2
1
Page 29
PLC connection
Mitsubishi
Phillips screws
MIL
XG4A-4031
34
(XW2R-J34GV-M2)
130.7
122.2
1
Page 29
PLC connection
Mitsubishi
Slotted screws
MIL
XG4A-4031
34
(XW2R-E34GV-M1)
98.5
90
2
Page 30
PLC connection
Mitsubishi
Slotted screws
MIL
XG4A-4031
34
(XW2R-E34GV-M2)
98.5
90
2
Page 30
PLC connection
Mitsubishi
Push-in spring
MIL
XG4A-4031
34
(XW2R-P34GV-M1)
98.5
90
3
Page 31
PLC connection
Mitsubishi
Push-in spring
MIL
XG4A-4031
34
(XW2R-P34GV-M2)
98.5
90
3
Page 31
PLC connection
Keyence
Phillips screws
MIL
XG4A-3431
34
(XW2R-J34GV-K1)
130.7
122.2
1
Page 35
PLC connection
Keyence
Phillips screws
MIL
XG4A-4031
40
(XW2R-J40GV-K2)
151.7
143.2
1
Page 35
PLC connection
Keyence
Push-in spring
MIL
XG4A-3431
34
(XW2R-P34GV-K1)
98.5
90
3
Page 36
PLC connection
Keyence
Push-in spring
MIL
XG4A-4031
40
(XW2R-P40GV-K2)
113.5
105
3
Page 36
Page 20
General-purpose
−
Phillips screws
MIL
XG4A-2031
20
(XW2R-J20GV-T)
81.7
73.2
1
Page 41
General-purpose
−
Phillips screws
MIL
XG4A-3431
34
(XW2R-J34GV-T)
130.7
122.2
1
Page 41
General-purpose
−
Phillips screws
MIL
XG4A-4031
40
(XW2R-J40GV-T)
151.7
143.2
1
Page 41
General-purpose
−
Phillips screws
MIL
XG4A-5031
50
(XW2R-J50GV-T)
186.7
178.2
1
Page 41
General-purpose
−
Phillips screws
MIL
XG4A-6031
60
(XW2R-J60GV-T)
221.7
213.2
1
Page 41
General-purpose
−
Phillips screws
FCN
FCN-364P040-AU
40
(XW2R-J40FV-T)
151.7
143.2
1
Page 41
General-purpose
−
Slotted screws
MIL
XG4A-2031
20
(XW2R-E20GV-T)
64.4
55.9
2
Page 42
General-purpose
−
Slotted screws
MIL
XG4A-3431
34
(XW2R-E34GV-T)
98.5
90
2
Page 42
General-purpose
−
Slotted screws
MIL
XG4A-4031
40
(XW2R-E40GV-T)
113.5
105
2
Page 42
General-purpose
−
Slotted screws
MIL
XG4A-5031
50
(XW2R-E50GV-T)
138.5
130
2
Page 42
General-purpose
−
Slotted screws
MIL
XG4A-6031
60
(XW2R-E60GV-T)
163.5
155
2
Page 42
General-purpose
−
Slotted screws
FCN
FCN-364P040-AU
40
(XW2R-E40FV-T)
113.5
105
2
Page 42
General-purpose
−
Push-in spring
MIL
XG4A-2031
20
(XW2R-P20GV-T)
64.4
55.9
3
Page 43
General-purpose
−
Push-in spring
MIL
XG4A-3431
34
(XW2R-P34GV-T)
98.5
90
3
Page 43
General-purpose
−
Push-in spring
MIL
XG4A-4031
40
(XW2R-P40GV-T)
113.5
105
3
Page 43
General-purpose
−
Push-in spring
MIL
XG4A-5031
50
(XW2R-P50GV-T)
138.5
130
3
Page 43
General-purpose
−
Push-in spring
MIL
XG4A-6031
60
(XW2R-P60GV-T)
163.5
155
3
Page 43
General-purpose
−
Push-in spring
FCN
FCN-364P040-AU
40
(XW2R-P40FV-T)
113.5
105
3
Page 43
PLC connection
Mitsubishi
MIL connector relay
MIL
XG4A-4031
40
(XW2R-G32GV-M1-COM)
98.5
90
5
Page 25
General-purpose
−
e-CON
MIL
XG4A-1431
14
(XW2R-N08GV-COM)
64.4
55.9
6
Page 39
Please consult your OMRON representative for the marketing dates for model in parentheses.
All models can be mounted to DIN track. For details, refer to page 9.
67
XW2R
Reference Dimensions Diagram Patterns
1
(Unit: mm)
2
MIL Plug:
XG4A-@@31
50
63.5
8.5
19.7
,4
4
7
8
30
31
32
33
34
35
36
37
38
39
40
1
2
3
4
5
6
7
8
30
31
32
33
34
35
36
37
38
39
40
NC 0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
NC
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
GGGGGGGGGGGGGGGGGG
8.5
Depends on
number of poles.
19.7
o,
Tw
Depends on
number of poles.
5(Pitch)
4.5
11
6
63.5
5
50
4
11
63.5
3
(44.81)
A
B
(44.81)
4.5
A
B
2
MIL Plug:
XG4A-@@31
50
MIL Plug:
XG4A-@@31
1
s
s
ole
ole
.h
.h
3
(43)
dia
.5-
dia
.5-
,4
Depends on
number of poles.
o
Tw
2.5
5(Pitch)
19.7
(48.05)
o
Tw
Depends on
8.5
number of poles.
5.8
11
M3
3.5
7(Pitch)
(44.81)
4.5
A
B
11
50
63.5
A
B
MIL Plug:
XG4A-@@31
(44.81)
4.5
8.5
Tw
o, 4
4.5
.5-d
ia.
-d
(33.1)
ia.
19.7
(33.1)
hol
es
les
ho
G
V
G
(44.81)
4.5
11
XG4A-1431
8.5
Tw
o,
4.5
-di
68
V
G
V
G
MIL Plug:
XG4A-1431
(44.81)
4.5
11
50
63.5
V
Power supply
terminal block
64.4
55.9
6
MIL Plug:
XG4A-4031
50
Power supply
terminal block
98.5
90
63.5
5
a.
ho
19.7
(33.1)
les
e-CON Sockets:
XN2D-4471 × 2
8.5 Tw
o
19.7
(30.8)
(33.1)
,4
.5-
dia
.h
ole
s
XW2R
Horizontal Screw Mounting
Type
Connected PLC
manufacturer
PLC connection
OMRON
Phillips screws
MIL
XG4A-4031
34
XW2R-J34G-C1
130.7
140.2
1
Page 20
PLC connection
OMRON
Phillips screws
MIL
XG4A-4031
34
XW2R-J34G-C2
130.7
140.2
1
Page 20
PLC connection
OMRON
Phillips screws
MIL
XG4A-4031
34
XW2R-J34G-C3
130.7
140.2
1
Page 20
PLC connection
OMRON
Phillips screws
MIL
XG4A-4031
34
XW2R-J34G-C4
130.7
140.2
1
Page 20
PLC connection
OMRON
Slotted screws
MIL
XG4A-4031
34
XW2R-E34G-C1
98.5
108
2
Page 21
PLC connection
OMRON
Slotted screws
MIL
XG4A-4031
34
XW2R-E34G-C2
98.5
108
2
Page 21
PLC connection
OMRON
Slotted screws
MIL
XG4A-4031
34
XW2R-E34G-C3
98.5
108
2
Page 21
PLC connection
OMRON
Slotted screws
MIL
XG4A-4031
34
XW2R-E34G-C4
98.5
108
2
Page 21
PLC connection
OMRON
Push-in spring
MIL
XG4A-4031
34
XW2R-P34G-C1
98.5
108
3
Page 22
PLC connection
OMRON
Push-in spring
MIL
XG4A-4031
34
XW2R-P34G-C2
98.5
108
3
Page 22
PLC connection
OMRON
Push-in spring
MIL
XG4A-4031
34
XW2R-P34G-C3
98.5
108
3
Page 22
PLC connection
OMRON
Push-in spring
MIL
XG4A-4031
34
XW2R-P34G-C4
98.5
108
3
Page 22
PLC connection
OMRON
Push-in spring
MIL
XG4A-2031
16
XW2R-P16G-C1-COM
98.5
108
4
Page 16
PLC connection
OMRON
Push-in spring
MIL
XG4A-2031
16
XW2R-P16G-C3-COM
98.5
108
4
Page 16
PLC connection
OMRON
Push-in spring
MIL
XG4A-4031
32
XW2R-P32G-C1-COM
186.7
196.2
4
Page 16
PLC connection
OMRON
Push-in spring
MIL
XG4A-4031
32
XW2R-P32G-C2-COM
186.7
196.2
4
Page 16
PLC connection
OMRON
Push-in spring
MIL
XG4A-4031
32
XW2R-P32G-C3-COM
186.7
196.2
4
Page 16
PLC connection
OMRON
Push-in spring
MIL
XG4A-4031
32
XW2R-P32G-C4-COM
186.7
196.2
4
Page 16
PLC connection
Mitsubishi
Phillips screws
MIL
XG4A-4031
34
XW2R-J34G-M1
130.7
140.2
1
Page 29
PLC connection
Mitsubishi
Phillips screws
MIL
XG4A-4031
34
XW2R-J34G-M2
130.7
140.2
1
Page 29
PLC connection
Mitsubishi
Slotted screws
MIL
XG4A-4031
34
XW2R-E34G-M1
98.5
108
2
Page 30
PLC connection
Mitsubishi
Slotted screws
MIL
XG4A-4031
34
XW2R-E34G-M2
98.5
108
2
Page 30
PLC connection
Mitsubishi
Push-in spring
MIL
XG4A-4031
34
XW2R-P34G-M1
98.5
108
3
Page 31
PLC connection
Keyence
Push-in spring
MIL
XG4A-4031
34
XW2R-P34G-M2
98.5
108
3
Page 31
PLC connection
Keyence
Phillips screws
MIL
XG4A-3431
34
XW2R-J34G-K1
130.7
140.2
1
Page 35
PLC connection
Keyence
Phillips screws
MIL
XG4A-4031
40
XW2R-J40G-K2
151.7
161.2
1
Page 35
PLC connection
Keyence
Push-in spring
MIL
XG4A-3431
34
XW2R-P34G-K1
98.5
108
3
Page 36
PLC connection
Keyence
Push-in spring
MIL
XG4A-4031
40
XW2R-P40G-K2
113.5
123
3
Page 36
General-purpose
−
Phillips screws
MIL
XG4A-2031
20
XW2R-J20G-T
81.7
91.2
1
Page 41
General-purpose
−
Phillips screws
MIL
XG4A-3431
34
XW2R-J34G-T
130.7
140.2
1
Page 41
General-purpose
−
Phillips screws
MIL
XG4A-4031
40
XW2R-J40G-T
151.7
161.2
1
Page 41
General-purpose
−
Phillips screws
MIL
XG4A-5031
50
XW2R-J50G-T
186.7
196.2
1
Page 41
General-purpose
−
Phillips screws
MIL
XG4A-6031
60
XW2R-J60G-T
221.7
231.2
1
Page 41
General-purpose
−
Phillips screws
FCN
FCN-364P040-AU
40
XW2R-J40F-T
151.7
161.2
1
Page 41
General-purpose
−
Slotted screws
MIL
XG4A-2031
20
XW2R-E20G-T
64.4
73.9
2
Page 42
General-purpose
−
Slotted screws
MIL
XG4A-3431
34
XW2R-E34G-T
98.5
108
2
Page 42
General-purpose
−
Slotted screws
MIL
XG4A-4031
40
XW2R-E40G-T
113.5
123
2
Page 42
General-purpose
−
Slotted screws
MIL
XG4A-5031
50
XW2R-E50G-T
138.5
148
2
Page 42
General-purpose
−
Slotted screws
MIL
XG4A-6031
60
XW2R-E60G-T
163.5
173
2
Page 42
General-purpose
−
Slotted screws
FCN
FCN-364P040-AU
40
XW2R-E40F-T
113.5
123
2
Page 42
General-purpose
−
Push-in spring
MIL
XG4A-2031
20
XW2R-P20G-T
64.4
73.9
3
Page 43
General-purpose
−
Push-in spring
MIL
XG4A-3431
34
XW2R-P34G-T
98.5
108
3
Page 43
General-purpose
−
Push-in spring
MIL
XG4A-4031
40
XW2R-P40G-T
113.5
123
3
Page 43
General-purpose
−
Push-in spring
MIL
XG4A-5031
50
XW2R-P50G-T
138.5
148
3
Page 43
General-purpose
−
Push-in spring
MIL
XG4A-6031
60
XW2R-P60G-T
163.5
173
3
Page 43
General-purpose
−
Push-in spring
FCN
FCN-364P040-AU
40
XW2R-P40F-T
113.5
123
3
Page 43
PLC connection
Mitsubishi
MIL connector relay
MIL
XG4A-4031
40
XW2R-G32G-M1-COM
108
98.5
5
Page 25
General-purpose
−
e-CON
MIL
XG4A-1431
14
XW2R-N08G-COM
73.9
64.4
6
Page 39
Wiring method
Mounted connector type
and model
Number of
poles
Model
Dimension A
Reference di- ReferDimen- mensions dience
sion B
agram,
wiring
pattern 1
diagram
All models can be mounted to DIN track. For details, refer to page 9.
69
XW2R
Reference Dimensions Diagram Patterns
(Unit: mm)
1
2
Depends on mounted connector.
The XG4A-@@31 MIL Connector Plug is shown.
B
A
Depends on mounted connector.
The XG4A-@@31 MIL Connector Plug is shown.
B
A
a.
-di
4.5
o,
Tw oles
h
50
29.75
8.5
20.25
(45.11)
a.
-di
4.5
o,
Tw oles
h
50
29.75
8.5
20.25
(45.11)
3.5 M3
7(Pitch)
9
Depends on mounted connector.
Depends on number of poles.
2
9
9
20
(48.35)
Depends on mounted connector.
4.5
4
Depends on mounted connector.
The XG4A-@@31 MIL Connector Plug is shown.
B
A
Depends on
model number.
Depends on
model number.
(45.11)
50
-d
4.5
o,
Tw oles
h
.
ia.
dia
4.5
o,
Tw oles
h
50
29.75
8.5
20.25
(45.11)
29.75
8.5
MIL Plug:
XG4A-@@31
B
A
20.25
3
9
2
9
5(Pitch)
Depends on mounted connector.
20
(43.3)
2.5
5(Pitch)
4.5
5.8
2
9
Depends on number of poles.
9
2
9
20
(33.4)
20
(33.4)
4.5
4.5
Depends on number of poles.
6
29.75
8.5
29.75
8.5
50
.
20
(33.4)
4.5
70
(45.11)
-dia
2
9
XG4A-1431
MIL Plug:
XG4A-1431
.5
o, 4
Tw oles
h
ia.
.5-d
o, 4
Tw oles
h
9
73.9
64.4
Power supply
terminal block
(45.11)
20.25
98.5
20.25
MIL Plug:
XG4A-4031
50
108
Power supply
terminal block
9
2
9
e-CON Sockets:
XN2D-4471 × 2
4.5
5
20
(31.1)
(33.4)
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
OMRON Corporation
Industrial Automation Company
Authorized Distributor:
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL60169 USA
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
© OMRON Corporation 2012-2015 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
CSM_8_3_0416
Cat. No. G077-E1-03
0315 (1012)(W)