Connector-Terminal Block Conversion Units for PLCs XW2R CSM_XW2R-C_M_K_DS_E_4_2 Connector-Terminal Block Conversion Units Designed Specifically to Connect PLCs • Wiring patterns that are specifically designed for PLCs reduce the work required to check signal layout. • Terminal block signal labels give the PLC addresses. • Models available with Phillips screw, slotted screw, push-in, or e-CON connections. • Models available with and without power supply terminals. • Mounting to DIN Track is possible. Item With power supply terminals Without power supply terminals PLC Maker OMRON Mitsubishi Keyence Model XW2R-@@@GD-C@-COM XW2R-@32GD-M@-COM XW2R-P32GD-K1-COM Page Page 2 Page 13 Page 22 Model XW2R-@34GD-C@ XW2R-@34GD-M@ XW2R-@@@GD-K@ Page Page 9 Page 18 Page 24 Appearance Appearance Options (Order Separately) Models that are mounted with screws are also available. Refer to the XW2R-series Connector-Terminal Block Conversion Units Catalog (Cat. No. G077) for details. Connecting Cables for Connector-Terminal Block Conversion Units Refer to the XW2Z datasheet. 1 XW2R Models for Connection to OMRON PLCs with power supply terminals Model List X W 2 R - @ @ @ G D - C @ - COM Wiring method I/O Points P 16 16 Points N Push-in spring e-CON Type Mounted Connector type G MIL (XG4A) 32 32 Points Mounting method D DIN Track mounting PLC type Power supply terminals C1 Refer to the C2 following table for 16-pole models C3 and to page 3 for C4 32-pole models. COM Provided Models for OMRON PLCs Models with 16 Poles I/O I/O Points 32 Input 64 16 I/O Unit Model CJ1W-ID231 CS1W-ID231 CJ1W-ID261 CS1W-ID261 CJ1W-MD231 (inputs) Models that connect to PLCs Connecting cables ∗ XW2R-P16GD-C1-COM: 2 pcs XW2R-N16GD-C1-COM: 2 pcs XW2Z-@@@D: 1 Cable XW2R-P16GD-C1-COM: 4 pcs XW2R-N16GD-C1-COM: 4 pcs XW2Z-@@@D: 2 Cables XW2R-P16GD-C1-COM: 1 pcs XW2R-N16GD-C1-COM: 1 pcs XW2Z-@@@A: 1 Cable XW2R-P16GD-C1-COM: 2 pcs XW2R-N16GD-C1-COM: 2 pcs XW2Z-@@@D: 1 Cable XW2R-P16GD-C1-COM: 2 pcs XW2R-N16GD-C1-COM: 2 pcs XW2Z-@@@N: 1 Cable XW2R-P16GD-C1-COM: 4 pcs XW2R-N16GD-C1-COM: 4 pcs XW2Z-@@@N: 2 Cables XW2R-P16GD-C3-COM: 2 pcs XW2Z-@@@L: 1 Cable XW2R-P16GD-C3-COM: 2 pcs XW2Z-@@@N: 2 Cables XW2R-P16GD-C3-COM: 4 pcs XW2Z-@@@L: 2 Cables XW2R-P16GD-C3-COM : 4 pcs XW2Z-@@@N: 2 Cables XW2R-P16GD-C3-COM: 1 pcs XW2Z-@@@A: 1 Cable XW2R-P16GD-C3-COM: 2 pcs XW2Z-@@@L: 1 Cable CJ1W-MD261 (inputs) I/O 32 CS1W-MD261 (inputs) CS1W-MD262 (inputs) CS1W-MD561 (inputs) CJ1W-ID232 Input 32 I/O Input CJ1W-ID233 CJ1W-MD263 (inputs) CJ1W-MD563 (inputs) 64 CJ1W-ID262 CJ1W-OD231 CS1W-OD231 32 CS1W-OD232 CJ1W-OD232 CJ1W-OD233 Output CJ1W-OD234 CJ1W-OD261 64 CS1W-OD261 CJ1W-OD262 CJ1W-OD263 16 CJ1W-MD231 (outputs) CJ1W-MD261 (outputs) I/O 32 CS1W-MD261 (outputs) CS1W-MD262 (outputs) CS1W-MD561 (outputs) * @@@ is replaced by the cable length. Refer to the XW2Z datasheet. Note: Connection is not possible to all OMRON PLC Units. This Connector-Terminal Block Conversion Unit is for NPN. For PNP, reverse the polarity of the external power supply and I/O on the Connector-Terminal Block Conversion Unit. 2 XW2R Models with 32 Poles I/O I/O Points 32 Input 64 I/O Unit Model CJ1W-ID231 CS1W-ID231 CJ1W-ID261 CS1W-ID261 Connecting cables ∗ Models that connect to PLCs XW2R-P32GD-C1-COM: 1 pcs XW2R-N32GD-C1-COM: 1 pcs XW2Z-@@@B: 1 Cable, or XW2Z-@@@@BF-L: 1 Cable XW2R-P32GD-C1-COM: 2 pcs XW2R-N32GD-C1-COM: 2 pcs XW2Z-@@@B: 2 Cables, or XW2Z-@@@@BF-L: 2 Cables XW2R-P32GD-C1-COM: 1 pcs XW2R-N32GD-C1-COM: 1 pcs XW2Z-@@@B: 1 Cable, or XW2Z-@@@@BF-L: 1 Cable XW2R-P32GD-C2-COM: 1 pcs XW2R-N32GD-C2-COM: 1 pcs XW2Z-@@@K: 1 Cable, or XW2Z-@@@@FF-L: 1 Cable XW2R-P32GD-C2-COM: 2 pcs XW2R-N32GD-C2-COM: 2 pcs XW2Z-@@@K: 2 Cables, or XW2Z-@@@@FF-L: 2 Cables XW2R-P32GD-C2-COM: 1 pcs XW2R-N32GD-C2-COM: 1 pcs XW2Z-@@@K: 1 Cable, or XW2Z-@@@@FF-L: 1 Cable XW2R-P32GD-C3-COM: 1 pcs XW2Z-@@@B: 1 Cable, or XW2Z-@@@@BF-L: 1 Cable XW2R-P32GD-C3-COM: 2 pcs XW2Z-@@@B: 2 Cables, or XW2Z-@@@@BF-L: 2 Cables XW2R-P32GD-C3-COM: 1 pcs XW2Z-@@@B: 1 Cable, or XW2Z-@@@@BF-L: 1 Cable XW2R-P32GD-C4-COM: 1 pcs XW2Z-@@@K: 1 Cable, or XW2Z-@@@@FF-L: 1 Cable XW2R-P32GD-C4-COM: 2 pcs XW2Z-@@@K: 2 Cables, or XW2Z-@@@@FF-L: 2 Cables XW2R-P32GD-C4-COM: 1 pcs XW2Z-@@@K: 1 Cable, or XW2Z-@@@@FF-L: 1 Cable CJ1W-MD261 (inputs) I/O 32 CS1W-MD261 (inputs) CS1W-MD262 (inputs) CS1W-MD561 (inputs) 32 Input 64 I/O 32 CJ1W-ID232 CJ1W-ID233 CJ1W-ID262 CJ1W-MD263 (inputs) CJ1W-MD563 (inputs) CJ1W-OD231 32 CS1W-OD231 CS1W-OD232 Output CJ1W-OD261 64 CS1W-OD261 CS1W-OD262 CJ1W-MD261 (outputs) I/O 32 CS1W-MD261 (outputs) CS1W-MD262 (outputs) CS1W-MD561 (outputs) CJ1W-OD232 32 64 I/O CJ1W-OD233 CJ1W-OD234 Output 32 CJ1W-OD262 CJ1W-OD263 CJ1W-MD263 (outputs) CJ1W-MD563 (outputs) * @@@@ is replaced by the cable length. Note: Connection is not possible to all OMRON PLC Units. This Connector-Terminal Block Conversion Unit is for NPN. For PNP, reverse the polarity of the external power supply and I/O on the Connector-Terminal Block Conversion Unit. Connection Examples 32-point Input Unit or Output Unit CJ1W-ID231 32-point CJ1W-OD231 32-point 64-point Input Unit or Output Unit CJ1W-ID261 64-point CJ1W-OD261 64-point Connection to 32 pts unit (Without branch) XW2Z-@@@B or XW2Z-@@@@BF-L Connection to 64 pts unit (Without branch) XW2Z-@@@B or XW2Z-@@@@BF-L 64-point I/O Unit CJ1W-MD563 IN 32 Points, OUT 32 Points Connection to 64 pts unit (Without branch) XW2Z-@@@K or XW2Z-@@@@FF-L outputs inputs 3 XW2R Models for Connection to OMRON PLCs with power supply terminals Application Example Power Supply Connections to Sensors and Actuators Can be used as crossovers to the next Unit. PLC Connecting Cables XW2Z-@@@B, XW2Z-@@@@BF-L Connectors: One 40-pin Connector Made by Fujitsu Component, Ltd. to One 40-pin MIL Connector Appearance Cable length L (m) 0.5 1 1.5 2 3 5 7 10 15 20 With shield Model XW2Z-050B XW2Z-100B XW2Z-150B XW2Z-200B XW2Z-300B XW2Z-500B XW2Z-700B XW2Z-010B XW2Z-15MB XW2Z-20MB Without shield Model XW2Z-0050BF-L XW2Z-0100BF-L XW2Z-0150BF-L XW2Z-0200BF-L XW2Z-0300BF-L XW2Z-0500BF-L XW2Z-0700BF-L XW2Z-1000BF-L ----- Wiring Diagram FCN367J040-AU/F (mating side) 1 1 2 2 XG4M-4030-T (mating side) Triangular mark 2 1 4 3 10 10 20 19 11 11 22 21 19 19 38 37 20 20 40 39 B A Cable length L (m) L XW2Z-@@@K, XW2Z-@@@@FF-L Connectors: One 40-pin Connector to One 40-pin MIL Connector Appearance Cable length L (m) 0.25 0.5 1 1.5 2 3 5 7 10 With shield Model XW2Z-C25K XW2Z-C50K XW2Z-100K XW2Z-150K XW2Z-200K XW2Z-300K XW2Z-500K --XW2Z-010K Without shield Model --XW2Z-0050FF-L XW2Z-0100FF-L XW2Z-0150FF-L XW2Z-0200FF-L XW2Z-0300FF-L XW2Z-0500FF-L XW2Z-0700FF-L XW2Z-1000FF-L Wiring Diagram XG4M-4030-T (mating side) XG4M-4030-T (mating side) Triangular mark 39 40 2 1 37 38 4 3 21 22 20 19 19 20 22 21 3 4 38 37 1 2 40 39 Triangular mark Note: Wire the connector terminals 1:1 so that the connector terminal numbers coincide. Cable length L (m) L 4 XW2R Models for Connection to OMRON PLCs with power supply terminals Push-in spring Ordering Information Appearance∗ I/O Points 16 Input/Output Model Dimension A (mm) Input XW2R-P16GD-C1-COM Output XW2R-P16GD-C3-COM 98.5 XW2R-P32GD-C1-COM Input XW2R-P32GD-C2-COM 32 186.7 XW2R-P32GD-C3-COM Output XW2R-P32GD-C4-COM * Input models (XW2R-P@@GD-C1/C2-COM) are black and output models (XW2R-P@@GD-C3/C4-COM) are green. Ratings and Specifications Rated current Rated voltage Insuration resistance Dielectric strength Ambient operating temperature Applicable Applicable wire sizes wires Stripped length Details on Crimp Terminals Square ferrules Applicable Ferrules 16 Points: 1A/signal, 4A/common 32 Points: 1A/signal, 8A/common 24VDC 100MΩ min. (at 500VDC) 500VAC for 1 ferrulemin (leakage current: 1 mA max.) B • Use ferrules of the lengths and thicknesses specified below.If other lengths or thicknesses are used, connection maynot be possible or it may not be possible to insert or remove the posts. 8-10 mm A Round ferrules Dia. C 8-10 mm • Ferrule Dimensions 0 to 55°C Square ferrules AWG 24 to 14 (ferrules) AWG 28 to 14 (stranded or solid) (Outer diameter of insulation must be 4 mm max) AWG28-16: 8 to 10 mm AWG14: 9 to 10 mm Round ferrules Dimension A (Width) 2.7 mm max. Dimension B (Height) 2 mm max. Dimension C (Diameter) 2 mm dia. max. (after crimping) The cross-sectional area after crimping must be 4.8 mm2 or less Refer to page 28 for information on Square/Round ferrule and use tool. Dimensions (Unit: mm) The label contents depend on the model. The label contents depend on the model. MIL Plug: XG4A-2031 A 50 (44.81) 19.7 (33.1) 5 XW2R Models for Connection to OMRON PLCs with power supply terminals Wiring Diagram XW2R-P16GD-C1-COM XW2R-P16GD-C3-COM MIL Connector MIL Connector (0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (NC) (0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (NC) (NC) (V) (V) (G) (G) External power supply (NC) External power supply Terminal Block XW2R-P32GD-C1-COM Terminal Block XW2R-P32GD-C2-COM MIL Connector MIL Connector (0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (NC) (0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (NC) (NC) (V) (V) (G) (G) External power supply (NC) External power supply Terminal Block XW2R-P32GD-C3-COM Terminal Block XW2R-P32GD-C4-COM MIL Connector MIL Connector (0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (NC) (0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (NC) (NC) (V) (V) (G) (G) External power supply (NC) External power supply Terminal Block Terminal Block Label Contents XW2R-P32GD-C1-COM, XW2R-P32GD-C3-COM XW2R-P32GD-C2-COM, XW2R-P32GD-C4-COM XW2R-P16GD-C1-COM XW2R-P16GD-C3-COM NC 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 NC NC 0 V V V V V V V V V V V V V V V V V V V G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G 1 2 V V V 4 5 6 V V 3 V V V V V 7 8 9 10 11 12 13 14 15 0 V V V V V V V 2 3 4 V V 1 V V V V 5 6 7 8 9 10 11 12 13 14 15 NC V V V V V V V V V V 6 XW2R Models for Connection to OMRON PLCs with power supply terminals e-CON Type Ordering Information Appearance I/O Points Input/Output 16 Input Model Dimension A (mm) XW2R-N16GD-C1-COM 98.5 XW2R-N32GD-C1-COM 32 186.7 XW2R-N32GD-C2-COM Ratings and Specifications Power supply terminal block: 4 A/16 poles or 8 A/32 poles Connectors/e-CON Connectors: 1 A (However, rated current of e-CON Connector depends on the wires that are used.) Rated voltage 24VDC Insuration resistance 100MΩ min. (at 500VDC) Dielectric strength 500VAC for 1 min (leakage current: 1 mA max.) Ambient operating temperature 0 to 55°C AWG 24 to 14 (ferrules) Applicable wire AWG 28 to 14 (stranded wires) sizes AWG 28 to 16 (solid wires)∗ Applicable (Outer diameter of insulation must be 4 mm max) wires AWG28-16: 8 to 10 mm Stripped length AWG14: 9 to 10 mm * This is the applicable range for the power supply terminal block. For the applicable wire sizes for I/O Connectors (e-CON), refer to page 27. Rated current Refer to page 27 for the recommended e-CON Connectors. Dimensions (Unit: mm) Two power supply terminal blocks MIL Plug:XG4A-@@31 (44.81) A (33.1) 50 7.5 e-CON Sockets: XN2D-4471: 4 sockets/16 poles 8 sockets/32 poles 19.7 The label contents depend on the model. (30.8) 7 XW2R Models for Connection to OMRON PLCs with power supply terminals Wiring Diagram XW2R-N16GD-C1-COM MIL Connector External power supply External power supply e-CON XW2R-N32GD-C1-COM Connector External power supply External power supply e-CON XW2R-N32GD-C2-COM Connector External power supply External power supply e-CON 8 XW2R Models for Connection to OMRON PLCs without power supply terminals Model List X W 2 R - @ 34 G D - C @ Wiring method Number of poles J Phillips screw E Slotted screw (rise up) P Push-in spring 34 34 poles (I/O points: 32 points) Mounted Connector type G MIL (XG4A) Mounting method D PLC type DIN Track mounting C1 C2 C3 C4 Refer to the following table for details. Models for OMRON PLCs I/O I/O Points 32 Input 64 I/O Unit Model CJ1W-ID231 CS1W-ID231 CJ1W-ID261 CS1W-ID261 Models that connect to PLCs ∗1 Connecting cables ∗2 XW2R-@34GD-C1: 1 pcs XW2Z-@@@B: 1 Cable, or XW2Z-@@@@BF-L: 1 Cable XW2R-@34GD-C1: 2 pcs XW2Z-@@@B: 2 Cables, or XW2Z-@@@@BF-L: 2 Cables XW2R-@34GD-C1: 1 pcs XW2Z-@@@B: 1 Cable, or XW2Z-@@@@BF-L: 1 Cable XW2R-@34GD-C2: 1 pcs XW2Z-@@@K: 1 Cable, or XW2Z-@@@@FF-L: 1 Cable XW2R-@34GD-C2: 2 pcs XW2Z-@@@K: 2 Cables, or XW2Z-@@@@FF-L: 2 Cables XW2R-@34GD-C2: 1 pcs XW2Z-@@@K: 1 Cable, or XW2Z-@@@@FF-L: 1 Cable XW2R-@34GD-C3: 1 pcs XW2Z-@@@B: 1 Cable, or XW2Z-@@@@BF-L: 1 Cable XW2R-@34GD-C3: 2 pcs XW2Z-@@@B: 2 Cables, or XW2Z-@@@@BF-L: 2 Cables XW2R-@34GD-C3: 1 pcs XW2Z-@@@B: 1 Cable, or XW2Z-@@@@BF-L: 1 Cable XW2R-@34GD-C4: 1 pcs XW2Z-@@@K: 1 Cable, or XW2Z-@@@@FF-L: 1 Cable XW2R-@34GD-C4: 2 pcs XW2Z-@@@K: 2 Cables, or XW2Z-@@@@FF-L: 2 Cables XW2R-@34GD-C4: 1 pcs XW2Z-@@@K: 1 Cable, or XW2Z-@@@@FF-L: 1 Cable CJ1W-MD261 (inputs) I/O 32 CS1W-MD261 (inputs) CS1W-MD262 (inputs) CS1W-MD561 (inputs) 32 Input 64 I/O 32 CJ1W-ID232 CJ1W-ID233 CJ1W-ID262 CJ1W-MD263 (inputs) CJ1W-MD563 (inputs) CJ1W-OD231 32 CS1W-OD231 CS1W-OD232 Output CJ1W-OD261 64 CS1W-OD261 CS1W-OD262 CJ1W-MD261 (outputs) I/O 32 CS1W-MD261 (outputs) CS1W-MD262 (outputs) CS1W-MD561 (outputs) CJ1W-OD232 32 CJ1W-OD234 Output 64 I/O CJ1W-OD233 32 CJ1W-OD262 CJ1W-OD263 CJ1W-MD263 (outputs) CJ1W-MD563 (outputs) *1 Replace the box (@) with the wiring method code (J, E, or P). *2 @@@@ is replaced by the cable length. For details, refer to page 4. Note: 1. Connection is not possible to all OMRON PLC Units. 2. There is one common for each 32 points. 9 XW2R Models for Connection to OMRON PLCs without power supply terminals Phillips screw Ordering Information Appearance I/O Points (Number of poles) Model XW2R-J34GD-C1 XW2R-J34GD-C2 32 (34) XW2R-J34GD-C3 XW2R-J34GD-C4 Ratings and Specifications Rated current Rated voltage Insuration resistance Dielectric strength Ambient operating temperature Applic able wires Details on Crimp Terminals Wiring Terminal Blocks • Using Crimp Terminals (With a Terminal Block with M3 Screws) Terminal Screw Tightening Torque • Use a tightening torque of 0.5 N·m when connecting wires or crimp terminals to the terminal block. 0.5 A/signal, 4 A/common 24VDC 100MΩ min. (at 500VDC) 500VAC for 1 min (leakage current: 1 mA max.) 0 to 55°C Applicable crimp terminals AWG 22 to 16 (round or forked crimp Applicable wire terminals) sizes AWG 26 to 16 (stranded or solid wires) Stripped length 9 mm Tightening 0.5 N·m Dimensions (Unit: mm) 5.8 mm max. Forked crimp terminals 3.2 mm 5.8 mm max. Applicable wires Round crimp terminals 1.25-3 AWG 22 to 16 (0.30 to 1.25 mm2) Forked crimp terminals 1.25Y-3 AWG 22 to 16 (0.30 to 1.25 mm2) Wiring Diagram XW2R-J34GD-C1 MIL Plug:XG4A-4031 Round crimp terminals 3.2 mm dia. XW2R-J34GD-C2 MIL Connector 130.7 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 50 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 MIL Connector (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) (NC) M3 3.5 7 (Pitch) The label contents depend on the model. 2 4 6 8 10 12 14 16 20 22 24 26 28 30 32 34 17/18 1 3 5 7 9 11 13 15 19 21 23 25 27 29 31 33 35/36 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) (COM) (NC) 1/2 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) 21/22 20 18 16 14 12 10 8 6 19 17 15 13 11 9 7 5 (COM) 3/4 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) 23/24 40 38 36 34 32 30 28 26 39 37 35 33 31 29 27 25 5.8 Terminal Block Terminal Block XW2R-J34GD-C3 XW2R-J34GD-C4 MIL Connector MIL Connector 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 (44.81) (+V) (+V) 19/20 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) 39/40 2 4 6 8 10 12 14 16 22 24 26 28 30 32 34 36 (0V) 17/18 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) 37/38 1 3 5 7 9 11 13 15 21 23 25 27 29 31 33 35 Terminal Block 1/2 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) 21/22 20 18 16 14 12 10 8 6 19 17 15 13 11 9 7 5 (0V) 3/4 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) 23/24 40 38 36 34 32 30 28 26 39 37 35 33 31 29 27 25 Terminal Block 19.7 (48.05) Label Contents XW2R-J34GD-C1, XW2R-J34GD-C2 XW2R-J34GD-C3, XW2R-J34GD-C4 10 XW2R Models for Connection to OMRON PLCs without power supply terminals Slotted screw (rise up) Ordering Information Appearance I/O Points (Number of poles) Model XW2R-E34GD-C1 XW2R-E34GD-C2 32 (34) XW2R-E34GD-C3 XW2R-E34GD-C4 Ratings and Specifications Rated current Rated voltage Insuration resistance Dielectric strength Ambient operating temperature Applicable wire Appli sizes cable Stripped length wires Tightening Details on Crimp Terminals 0.5 A/signal, 4 A/common 24VDC 100MΩ min. (at 500VDC) 500VAC for 1 min (leakage current: 1 mA max.) Applicable crimp terminals Rod 0 to 55°C Blade AWG 22 to 16 (ferrules) AWG 26 to 16 (stranded or solid wires) 7 mm 0.5 to 0.6 N·m Dimensions (Unit: mm) TC-05 Dia. = 1 Round rod Dia. AWG22 to AWG18 (0.30 to 0.75 mm2) TC-1.25S Dia. = 1.5 AWG22 to AWG16 (0.30 to 1.25 mm2) BT1.25-9-1 BT1.25-10-1 W = 2.2 AWG22 to AWG16 (0.30 to 1.25 mm2) 8-10 mm Blade t = 0.75 8-10 mm W Note: Round rod and blade crimp terminals are made by Nichifu. Wiring Diagram XW2R-E34GD-C1 MIL Plug: XG4A-4031 Applicable wires XW2R-E34GD-C2 MIL Connector MIL Connector 98.5 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 50 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) (NC) The label contents depend on the model. 2.5 5 (Pitch) 2 4 6 8 10 12 14 16 20 22 24 26 28 30 32 34 17/18 1 3 5 7 9 11 13 15 19 21 23 25 27 29 31 33 35/36 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) (COM) (NC) 1/2 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) 21/22 20 18 16 14 12 10 8 6 19 17 15 13 11 9 7 5 (COM) 3/4 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) 23/24 40 38 36 34 32 30 28 26 39 37 35 33 31 29 27 25 Terminal Block XW2R-E34GD-C3 Terminal Block XW2R-E34GD-C4 MIL Connector MIL Connector 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 (44.81) (+V) (+V) 19/20 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) 39/40 2 4 6 8 10 12 14 16 22 24 26 28 30 32 34 36 1/2 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) 21/22 20 18 16 14 12 10 8 6 19 17 15 13 11 9 7 5 (0V) (0V) 17/18 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) 37/38 1 3 5 7 9 11 13 15 21 23 25 27 29 31 33 35 Terminal Block 3/4 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) 23/24 40 38 36 34 32 30 28 26 39 37 35 33 31 29 27 25 Terminal Block 19.7 (43) Label Contents XW2R-E34GD-C1, XW2R-E34GD-C2 XW2R-E34GD-C3, XW2R-E34GD-C4 11 XW2R Models for Connection to OMRON PLCs without power supply terminals Push-in spring Ordering Information Appearance I/O Points (Number of poles) Model XW2R-P34GD-C1 XW2R-P34GD-C2 32 (34) XW2R-P34GD-C3 XW2R-P34GD-C4 Ratings and Specifications Rated current Rated voltage Insuration resistance Dielectric strength Ambient operating temperature Stripped length Square ferrules 0.5 A/signal, 4 A/common 24VDC 100MΩ min. (at 500VDC) 500VAC for 1 min (leakage current: 1 mA max.) Applicable Ferrules • Use ferrules of the lengths and thicknesses specified below.If other lengths or thicknesses are used, connection maynot be possible or it may not be possible to insert or remove the posts. 0 to 55°C Ferrule Dimensions AWG 24 to 14 (ferrules) AWG 28 to 14 (stranded or solid) (Outer diameter of insulation must be 4 mm max) AWG28-16: 8 to 10 mm AWG14: 9 to 10 mm Applicable wire sizes Applicable wires Details on Crimp Terminals Dimensions (Unit: mm) Square ferrules Round ferrules 8-10 mm A Round ferrules Dia. C Dimension A (Width) 2.7 mm max. Dimension B (Height) 2 mm max. Dimension C (Diameter) 2 mm dia. max. (after crimping) 8-10 mm The cross-sectional area after crimping must be 4.8 mm2 or less Refer to page 28 for information on Square/Round ferrule and use tool. Wiring Diagram XW2R-P34GD-C1 MIL Plug:XG4A-4031 B XW2R-P34GD-C2 MIL Connector MIL Connector 98.5 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 50 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 1& &20 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) (NC) 2 4 6 8 10 12 14 16 20 22 24 26 28 30 32 34 17/18 1 3 5 7 9 11 13 15 19 21 23 25 27 29 31 33 35/36 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) The label contents depend on the model. (COM) 5 (Pitch) (NC) 1/2 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) 21/22 20 18 16 14 12 10 8 6 19 17 15 13 11 9 7 5 (COM) 3/4 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) 23/24 40 38 36 34 32 30 28 26 39 37 35 33 31 29 27 25 Terminal Block XW2R-P34GD-C3 Terminal Block XW2R-P34GD-C4 MIL Connector MIL Connector 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 (44.81) (+V) (+V) 19/20 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) 39/40 2 4 6 8 10 12 14 16 22 24 26 28 30 32 34 36 (0V) 17/18 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) 37/38 1 3 5 7 9 11 13 15 21 23 25 27 29 31 33 35 Terminal Block 1/2 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) 21/22 20 18 16 14 12 10 8 6 19 17 15 13 11 9 7 5 (0V) 3/4 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (10) (11) (12) (13) (14) (15) 23/24 40 38 36 34 32 30 28 26 39 37 35 33 31 29 27 25 Terminal Block 19.7 (33.1) Label Contents XW2R-P34GD-C1, XW2R-P34GD-C2 m+1 XW2R-P34GD-C3, XW2R-P34GD-C4 m+1 12 XW2R Models for Connection to Mitsubishi PLCs with power supply terminals Model List X W 2 R - @ 3 2 G D - M @ - COM Wiring method P Push-in spring I/O Points 32 32 Points Mounted Connector type G MIL (XG4A) Mounting method D DIN Track mounting G MIL Connector PLC type Power supply terminals M1 Refer to the following M2 table for details. COM Provided Models for Connection to Mitsubishi PLCs I/O Points Mitsubishi PLC Module model Connecting cables ∗ Models that connect to PLCs LX41C4 QX41 QX41-S1 32 QX41-S2 XW2R-P32GD-M1-COM: 1 pcs XW2Z-@@@B: 1 Cable, or XW2Z-@@@@BF-L: 1 Cable XW2R-P32GD-M1-COM: 2 pcs XW2Z-@@@B: 2 Cables, or XW2Z-@@@@BF-L: 2 Cables XW2R-P32GD-M2-COM: 1 pcs XW2Z-@@@B: 1 Cable, or XW2Z-@@@@BF-L: 1 Cable XW2R-P32GD-M2-COM: 2 pcs XW2Z-@@@B: 2 Cables, or XW2Z-@@@@BF-L: 2 Cables QX71 QH42P (Input) QX41Y41P (Input) LX42C4 QX42 64 QX42-S1 QX82 QX82-S1 LY41NT1P QY41P 32 QY71 QH42P (Output) QX41Y41P (Output) LY42NT1P 64 QY42P QY82P * @@@@ is replaced by the cable length. Note: This Connector-Terminal Block Conversion Unit is for NPN. For PNP, reverse the polarity of the external power supply and I/O on the Connector-Terminal Block Conversion Unit. XW2Z-@@@B, XW2Z-@@@@BF-L Connectors: One 40-pin Connector Made by Fujitsu Component, Ltd. to One 40-pin MIL Connector Appearance Wiring Diagram Cable length L (m) With shield Without shield Model Model 0.5 XW2Z-050B XW2Z-0050BF-L 1 XW2Z-100B XW2Z-0100BF-L 1.5 XW2Z-150B XW2Z-0150BF-L 2 XW2Z-200B XW2Z-0200BF-L 3 XW2Z-300B XW2Z-0300BF-L 5 XW2Z-500B XW2Z-0500BF-L 7 XW2Z-700B XW2Z-0700BF-L 10 XW2Z-010B XW2Z-1000BF-L 15 XW2Z-15MB --- 19 19 20 XW2Z-20MB --- 20 20 FCN367J040-AU/F (mating side) 1 1 2 2 2 1 4 3 10 10 20 19 11 11 22 21 38 37 40 39 B Cable length L (m) XG4M-4030-T (mating side) Triangular mark A L 13 XW2R Models for Connection to Mitsubishi PLCs with power supply terminals MIL Connector Models for Connection to Mitsubishi PLCs I/O Points Model Models that connect to PLCs 32 QH42P (Input) , QX41Y41P (Input) XW2R-G32GD-M1-COM: 1 pcs XW2R-G32GD-M1-COM: 2 pcs Connection A XW2Z-@@@B: 2 Cables, or XW2Z-@@@@BF-L: 2 Cables Connection B XW2Z-@@@AA: 8 Cables LX41C4 QX42, QX42-S1, QX82, QX82-S1 64 Connecting cables∗ Connection A XW2Z-@@@B: 1 Cable, or XW2Z-@@@@BF-L: 1 Cable Connection B XW2Z-@@@AA: 4 Cables QX41, QX41-S1, QX41-S2, QX71 LX42C4 * @@@@ is replaced by the cable length. Note: Refer to page 13 for information on the XW2Z-@@@B and XW2Z-@@@@BF-L. This Connector-Terminal Block Conversion Unit is for NPN. For PNP,reverse the polarity of the external power supply and I/O on the Connector-Terminal Block Conversion Unit. XW2Z-@@@AA One 14-pin MIL Connector to One 14-pin MIL Connector Appearance Wiring Diagram With shield Cable length L (m) Model 0.5 XW2Z-050AA 1 XW2Z-100AA 2 XW2Z-200AA 5 XW2Z-500AA 10 XW2Z-010AA Cable length L (m) Note: Wire the connector terminals 1:1 so that the connector terminal numbers coincide. L Connection Examples controller Connection A XW2Z-@@@B or XW2Z-@@@@BF-L The 32 PLC inputs are separated into groups of 8 inputs. XW2R-G32GD-M1-COM Connection B XW2Z-@@@AA By distributing the input locations, less work is required for changes to sensors and other devices. XW2R-N08GD-COM (e-CON Connectors: 4 poles × 8) XN2A-1470 (e-CON Connector: 4 poles) Connection to sensor Relay Connector XN2B-1470 (e-CON Connector: 4 poles) XN2A-1470 (e-CON Connector: 4 poles) 14 XW2R Models for Connection to Mitsubishi PLCs with power supply terminals Ordering Information Appearance Model Number of poles 40 poles x 1 point 14 poles x 4 points XW2R-G32GD-M1-COM Ratings and Specifications Rated current Power supply terminal block: 8A Connectors: 1A Rated voltage 24VDC Insuration resistance 100MΩ min. (at 500VDC) Dielectric strength 500VAC for 1 min (leakage current: 1 mA max.) Ambient operating temperature 0 to 55°C Applicable wires Wiring Diagram MIL Connector External power supply AWG 24 to 14 (ferrules) AWG 28 to 14 (stranded wires) Applicable AWG 28 to 16 (solid wires) wire sizes (Outer diameter of insulation must be 4 mm max) Stripped length AWG28-16: 8 to 10 mm, AWG14: 9 to 10 mm MIL Connector MIL Connector MIL Connector MIL Connector Dimensions (Unit: mm) Power supply terminal block MIL Plug: XG4A-4031 98.5 G G 50 V V 44.8 MIL Plug: XG4A-1431 19.7 (33.1) 15 XW2R Models for Connection to Mitsubishi PLCs with power supply terminals Ordering Information Appearance I/O Points Number of poles (PLC end) I/O Model 8 points 14 poles Input XW2R-N08GD-COM Ratings and Specifications Rated voltage Insuration resistance Dielectric strength Ambient operating temperature 0 to 55°C Applicable wire Applicable sizes ∗ wires Stripped length XG4A-1431 (PLC end) XN2D-4471 (for input) Cable Connector model XG4M-1430-T (PLC end) XN2A-1470 (for input) Wiring Diagram Power supply terminal block: 2A Connectors/e-CON Connectors: 1 A (However, rated current of e-CON Connector depends on the wires that are used.) 24VDC 100MΩ min. (at 500VDC) 500VAC for 1 min (leakage current: 1 mA max.) Rated current Mounted Connector model MIL Connector External power supply AWG 24 to 14 (ferrules), AWG 28 to 14 (stranded wires), AWG 28 to 16 (solid wires) (Outer diameter of insulation must be 4 mm max) AWG28-16: 8 to 10 mm, AWG14: 9 to 10 mm * This is the applicable range for the power supply terminal block. For the applicable wire sizes for I/O Connectors (e-CON), refer to page 27. e-CON (This connection diagram is for combining with CN1 on the XW2R-G32GD-M1-COM.) Refer to page 27 for the recommended e-CON Connectors. Dimensions Power supply terminal block (Unit: mm) MIL Plug: XG4A-1431 64.4 G V G 50 V (44.8) 19.7 e-CON Sockets: XN2D-4471 × 2 (30.8) (33.1) The e-CON address assignments are for combining the XW2R-G32GD-M1-COM with four XW2R-N08GD-COM. CN3 CN4 CN1 CN2 16 XW2R Models for Connection to Mitsubishi PLCs with power supply terminals Push-in spring Ordering Information Appearance I/O Points Input/Output Model Input XW2R-P32GD-M1-COM Output XW2R-P32GD-M2-COM 32 points Ratings and Specifications Rated current Rated voltage Insuration resistance Dielectric strength Ambient operating temperature Details on Crimp Terminals Applicable Ferrules 1 A/signal, 8 A/common 24VDC 100MΩ min. (at 500VDC) 500VAC for 1 min (leakage current: 1 mA max.) 8-10 mm A Round ferrules Dia. C 8-10 mm • Ferrule Dimensions Square ferrules AWG 24 to 14 (ferrules) AWG 28 to 14 (stranded or solid) (Outer diameter of insulation must be 4 mm max) AWG28-16: 8 to 10 mm AWG14: 9 to 10 mm Appli cable wires Stripped length B • Use ferrules of the lengths and thicknesses specified below.If other lengths or thicknesses are used, connection maynot be possible or it may not be possible to insert or remove the posts. 0 to 55°C Applicable wire sizes Square ferrules Round ferrules Dimension A (Width) Dimension B (Height) Dimension C (Diameter) 2.7 mm max. The cross-sectional area after crimping must 2 mm max. be 4.8 mm2 or less 2 mm dia. max. (after crimping) Refer to page 28 for information on Square/Round ferrule and use tool. Dimensions (Unit: mm) The label contents depend on the model. The label contents depend on the model. MIL Plug: XG4A-4031 (44.81) NC 00 01 02 03 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F NC V V V V V V 04 V 05 V 06 V 07 V 08 V 09 0A V V V V V V V V V V V V V V V V V V V V V V V G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G Terminal block word mCH side (warm gray) 50 186.7 Terminal block word (m+1)CH side (light gray) 19.7 (33.1) Wiring Diagram XW2R-P32GD-M1-COM XW2R-P32GD-M2-COM MIL Connector External power supply Terminal Block MIL Connector External power supply Terminal Block Label Contents XW2R-P32GD-M1-COM, XW2R-P32GD-M2-COM Row 1 Row 2 Row 3 mC H (m+1)CH NC 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F NC V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G 17 XW2R Models for Connection to Mitsubishi PLCs without power supply terminals Model List X W 2 R - @ 34 G D - M @ Wiring method Number of poles J 34 poles 34 (I/O points: 32 points) Phillips screw E Slotted screw (rise up) Mounted Connector type G MIL (XG4A) Mounting method PLC Type D DIN Track mounting M1 Refer to the following M2 table for details. P Push-in spring Models for Connection to Mitsubishi PLCs PLC Type I/O Points Mitsubishi PLC Module model Models that connect to PLCs ∗1 Connecting cables ∗2 LX41C4 QX41 QX41-S1 32 QX41-S2 XW2R-@34GD-M1: 1 pcs XW2Z-@@@B: 1 Cable, or XW2Z-@@@BF-L: 1 Cable XW2R-@34GD-M1: 2 pcs XW2Z-@@@B: 2 Cables, or XW2Z-@@@@BF-L: 2 Cables XW2R-@34GD-M2: 1 pcs XW2Z-@@@B: 1 Cable, or XW2Z-@@@@BF-L: 1 Cable XW2R-@34GD-M2: 2 pcs XW2Z-@@@B: 2 Cables, or XW2Z-@@@@BF-L: 1 Cable QX71 QH42P (Input) M1 QX41Y41P (Input) LX42C4 QX42 64 QX42-S1 QX82 QX82-S1 LY41NT1P QY41P 32 QY71 QH42P (Output) M2 QX41Y41P (Output) LY42NT1P QY42P 64 QY82P *1 Replace the box (@) with the wiring method code (J, E, or P). *2 @@@@ is replaced by the cable length. XW2Z-@@@B, XW2Z-@@@@BF-L Connectors: One 40-pin Connector Made by Fujitsu Component, Ltd. to One 40-pin MIL Connector Appearance Wiring Diagram With shield With shield Model Model 0.5 XW2Z-050B XW2Z-0050BF-L 1 XW2Z-100B XW2Z-0100BF-L 1.5 XW2Z-150B XW2Z-0150BF-L 2 XW2Z-200B XW2Z-0200BF-L 3 XW2Z-300B XW2Z-0300BF-L 5 XW2Z-500B XW2Z-0500BF-L 10 10 7 XW2Z-700B XW2Z-0700BF-L 11 11 10 XW2Z-010B XW2Z-1000BF-L 15 XW2Z-15MB --- 19 19 20 XW2Z-20MB --- 20 20 Cable length L (m) FCN367J040-AU/F (mating side) 1 1 2 2 2 1 4 3 20 19 22 21 38 37 40 39 B Cable length L (m) XG4M-4030-T (mating side) Triangular mark A L 18 XW2R Models for Connection to Mitsubishi PLCs without power supply terminals Phillips screw Ordering Information Appearance I/O Points (Number of poles) Model XW2R-J34GD-M1 32 (34) XW2R-J34GD-M2 Ratings and Specifications Rated current Rated voltage Insuration resistance Dielectric strength Ambient operating temperature Applicable Appli wire sizes cable Stripped length wires Tightening Details on Crimp Terminals 0.5 A/signal, 2 A/common 24VDC 100MΩ min. (at 500VDC) 500VAC for 1 min (leakage current: 1 mA max.) 0 to 55°C AWG 22 to 16 (round or forked crimp terminals) AWG 26 to 16 (stranded or solid wires) 9 mm 0.5 N·m Wiring Terminal Blocks • Using Crimp Terminals (With a Terminal Block with M3 Screws) Terminal Screw Tightening Torque • Use a tightening torque of 0.5 N·m when connecting wires or crimp terminals to the terminal block. Applicable crimp terminals Round crimp terminals 3.2 mm dia. 5.8 mm max. Forked crimp terminals 3.2 mm 5.8 mm max. Applicable wires Round crimp terminals 1.25-3 AWG 22 to 16 (0.30 to 1.25 mm2) Forked crimp terminals 1.25Y-3 AWG 22 to 16 (0.30 to 1.25 mm2) Dimensions (Unit: mm) MIL Plug: XG4A-4031 130.7 50 (44.81) M3 3.5 7 (Pitch) 19.7 The label contents depend on the model. 5.8 (48.05) Wiring Diagram XW2R-J34GD-M2 XW2R-J34GD-M1 MIL Connector MIL Connector 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 (COM) 2 39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 4 (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (1A) (1B) (1C) (1D) (1E) (1F) 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 1 3 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (0A) (0B) (0C) (0D) (0E) (0F) (+V) 2 39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 4 (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (1A) (1B) (1C) (1D) (1E) (1F) 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 1 3 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (0A) (0B) (0C) (0D) (0E) (0F) (0V) (NC) Terminal Block Terminal Block Label Contents XW2R-J34GD-M1 XW2R-J34GD-M2 19 XW2R Models for Connection to Mitsubishi PLCs without power supply terminals Slotted screw (rise up) Ordering Information Appearance I/O Points (Number of poles) Model XW2R-E34GD-M1 32 (34) XW2R-E34GD-M2 Ratings and Specifications Rated current Rated voltage Insuration resistance Dielectric strength Ambient operating temperature Applicable wire Applic sizes able Stripped length wires Tightening Details on Crimp Terminals Applicable crimp terminals 0.5 A/signal, 2 A/common 24VDC 100MΩ min. (at 500VDC) 500VAC for 1 min (leakage current: 1 mA max.) Rod 0 to 55°C Blade AWG 22 to 16 (ferrules) AWG 26 to 16 (stranded or solid wires) 7 mm 0.5 to 0.6 N·m TC-05 Dia. = 1 Applicable wires Round rod Dia. AWG22 to AWG18 (0.30 to 0.75 mm2) TC-1.25S Dia. = 1.5 AWG22 to AWG16 (0.30 to 1.25 mm2) BT1.25-9-1 BT1.25-10-1 W = 2.2 AWG22 to AWG16 (0.30 to 1.25 mm2) 8-10 mm Blade t = 0.75 8-10 mm W Note: Round rod and blade crimp terminals are made by Nichifu. Dimensions (Unit: mm) MIL Plug: XG4A-4031 (44.81) 50 98.5 The label contents depend on the model. 19.7 2.5 5 (Pitch) (43) Wiring Diagram XW2R-E34GD-M1 XW2R-E34GD-M2 MIL Connector MIL Connector 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 (COM) (+V) (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (1A) (1B) (1C) (1D) (1E) (1F) 2 39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 4 (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (1A) (1B) (1C) (1D) (1E) (1F) 2 39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 4 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 1 3 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (0A) (0B) (0C) (0D) (0E) (0F) (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (0A) (0B) (0C) (0D) (0E) (0F) (NC) Terminal Block 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 1 3 (0V) Terminal Block Label Contents XW2R-E34GD-M1 XW2R-E34GD-M2 20 XW2R Models for Connection to Mitsubishi PLCs without power supply terminals Push-in spring Ordering Information Appearance I/O Points (Number of poles) Model XW2R-P34GD-M1 32 (34) XW2R-P34GD-M2 Ratings and Specifications Rated current Rated voltage Insuration resistance Dielectric strength Ambient operating temperature Applicable Applicable wire sizes wires Stripped length Details on Crimp Terminals Square ferrules Applicable Ferrules • Use ferrules of the lengths and thicknesses specified below.If other lengths or thicknesses are used, connection maynot be possible or it may not be possible to insert or remove the posts. 0.5 A/signal, 2 A/common 24VDC 100MΩ min. (at 500VDC) 500VAC for 1 min (leakage current: 1 mA max.) B 8-10 mm A Round ferrules Dia. C 8-10 mm Ferrule Dimensions 0 to 55°C AWG 24 to 14 (ferrules) AWG 28 to 14 (stranded or solid) (Outer diameter of insulation must be 4 mm max) AWG28-16: 8 to 10 mm AWG14: 9 to 10 mm Square ferrules Round ferrules Dimension A (Width) 2.7 mm max. Dimension B (Height) 2 mm max. Dimension C (Diameter) 2 mm dia. max. (after crimping) The cross-sectional area after crimping must be 4.8 mm2 or less Refer to page 28 for information on Square/Round ferrule and use tool. Dimensions (Unit: mm) MIL Plug: XG4A-4031 98.5 50 (44.81) 10 11 12 13 14 15 00 01 02 03 04 05 16 06 17 07 18 08 19 09 1A 0A 1B 1C 1D 1E 1F COM 0B 0C 0D 0E 0F NC The label contents depend on the model. 19.7 5 (Pitch) (33.1) Wiring Diagram XW2R-P34GD-M1 XW2R-P34GD-M2 MIL Connector MIL Connector 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 (+V) (COM) (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (1A) (1B) (1C) (1D) (1E) (1F) 2 39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 4 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 1 3 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (0A) (0B) (0C) (0D) (0E) (0F) (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (1A) (1B) (1C) (1D) (1E) (1F) 2 39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 4 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 1 3 (00) (01) (02) (03) (04) (05) (06) (07) (08) (09) (0A) (0B) (0C) (0D) (0E) (0F) (0V) (NC) Terminal Block Terminal Block Label Contents XW2R-P34GD-M1 XW2R-P34GD-M2 21 XW2R Models for Keyence PLCs with power supply terminals Model List X W 2 R - P 3 2 G D - K 1 - COM Wiring method I/O Points P Push-in spring 32 32 Points Mounted Connector type G MIL (XG4A) Mounting method D DIN Track mounting Power supply terminals PLC Type K1 Refer to the following table for details. COM Provided Models for Keyence PLCs I/O I/O Points 32 Input 64 Unit Models for Keyence PLCs Input Unit Model Models that connect to PLCs Connecting cables∗ KV-C32XA, KV-C32XC XW2R-P32GD-K1-COM:1 pcs XW2Z-@@@EE: 1 Cable, or XW2Z-@@@@EE-L: 1 Cable KV-C64XA, KV-C64XB, KV-C64XC XW2R-P32GD-K1-COM:2 pcs XW2Z-@@@EE: 2 Cables, or XW2Z-@@@@EE-L: 2 Cables * @@@@ is replaced by the cable length. Note: This Connector-Terminal Block Conversion Unit is for NPN. For PNP,reverse the polarity of the external power supply and I/O on the Connector-Terminal Block Conversion Unit. XW2Z-@@@EE, XW2Z-@@@EE-L Connectors: One 34-pin MIL Connector to One 34-pin MIL Connector Appearance Cable length L (m) With shield Without shield Model Model 0.5 XW2Z-050EE XW2Z-0050EE-L 1 XW2Z-100EE XW2Z-0100EE-L 1.5 XW2Z-150EE XW2Z-0150EE-L 2 XW2Z-200EE XW2Z-0200EE-L 3 XW2Z-300EE XW2Z-0300EE-L 5 XW2Z-500EE XW2Z-0500EE-L 7 --- XW2Z-0700EE-L 10 --- XW2Z-1000EE-L Cable length L (m) L Wiring Diagram XG4M-3430-T (mating side) XG4M-3430-T (mating side) Triangular mark Triangular mark Note: Wire the connector terminals 1:1 so that the connector terminal numbers coincide. 22 XW2R Models for Keyence PLCs with power supply terminals Push-in spring Ordering Information Appearance I/O Points Model 32 XW2R-P32GD-K1-COM Ratings and Specifications Rated current Rated voltage Insuration resistance Dielectric strength Ambient operating temperature Applicable Applicable wire sizes wires Stripped length Details on Crimp Terminals Square ferrules Applicable Ferrules • Use ferrules of the lengths and thicknesses specified below.If other lengths or thicknesses are used, connection maynot be possible or it may not be possible to insert or remove the posts. 1 A/signal, 8 A/common 24VDC 100MΩ min. (at 500VDC) 500VAC for 1 min (leakage current: 1 mA max.) B 8-10 mm A Round ferrules Dia. C 8-10 mm • Ferrule Dimensions 0 to 55°C AWG 24 to 14 (ferrules) AWG 28 to 14 (stranded or solid) (Outer diameter of insulation must be 4 mm max) AWG28-16: 8 to 10 mm AWG14: 9 to 10 mm Square ferrules Round ferrules Dimension A (Width) 2.7 mm max. Dimension B (Height) 2 mm max. Dimension C (Diameter) 2 mm dia. max. (after crimping) The cross-sectional area after crimping must be 4.8 mm2 or less Refer to page 28 for information on Square/Round ferrule and use tool. Dimensions (Unit: mm) The label contents depend on the model. MIL Connector: XG4A-3431 186.7 50 (44.81) 19.7 Terminal block word mCH side (warm gray) Terminal block word (m+1)CH side (light gray) (33.1) Wiring Diagram XW2R-P32GD-K1-COM MIL Connector External power supply Terminal Block Label Contents XW2R-P32GD-K1-COM mCH (m+1)CH NC 000 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 NC V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G 23 XW2R Models for Keyence PLCs without power supply terminals Model List XW2R - @ Wiring method Number of poles @ @ G D - K @ Mounted Connector type *1 J Phillips screw 34 34 poles (I/O points: 32 points) P Push-in spring 40 40 poles (I/O points: 36 points)*2 G MIL (XG4A) Mounting method PLC Type D DIN Track mounting K1 Refer to the following K2 table for details. *1. K1 Type *2. K2 Type Models for Keyence PLCs I/O I/O Points Unit Output Output --- Connecting cables ∗2 KV-C32XA, KV-C32XC KV-C32TA, KV-C32TC, KV-C32TCP 32 KV-C32TD I/O Unit Model I/O Input Models that connect to PLCs ∗1 Models for Keyence PLCs Input XW2Z-@@@EE: 1 Cable, or XW2Z-@@@@EE-L: 1 Cable XW2R-@34GD-K1: 2 pcs XW2Z-@@@EE: 2 Cables, or XW2Z-@@@@EE-L: 2 Cables XW2R-@40GD-K2: 1 pcs XW2Z-@@@K: 1 Cable, or XW2Z-@@@@FF-L: 1 Cable KV-C32XTD KV-C64XA, KV-C64XB, KV-C64XC 64 --- XW2R-@34GD-K1: 1 pcs KV-C64TA, KV-C64TC, KV-C64TD, KV-C64TCP CPU Unit Model KV-1000, KV-3000, KV-5000, KV-5500 *1 Replace the box (@) with the wiring method code (J or P). *2 @@@@ is replaced by the cable length. XW2Z-@@@EE, XW2Z-@@@@EE-L Connectors: One 34-pin MIL Connector to One 34-pin MIL Connector Appearance Cable length L (m) 0.5 1 1.5 2 3 5 7 10 With shield Model XW2Z-050EE XW2Z-100EE XW2Z-150EE XW2Z-200EE XW2Z-300EE XW2Z-500EE ----- Without shield Model XW2Z-0050EE-L XW2Z-0100EE-L XW2Z-0150EE-L XW2Z-0200EE-L XW2Z-0300EE-L XW2Z-0500EE-L XW2Z-0700EE-L XW2Z-1000EE-L Wiring Diagram XG4M-3430-T (mating side) XG4M-3430-T (mating side) Triangular mark Triangular mark Cable length L (m) Note: Wire the connector terminals 1:1 so that the connector terminal numbers coincide. L XW2Z-@@@K, XW2Z-@@@@FF-L Connectors: One 40-pin MIL Connector to One 40-pin MIL Connector Appearance Cable length L (m) 0.25 0.5 1 1.5 2 3 5 7 10 Cable length L (m) With shield Model XW2Z-C25K XW2Z-C50K XW2Z-100K XW2Z-150K XW2Z-200K XW2Z-300K XW2Z-500K --XW2Z-010K Without shield Model --XW2Z-0050FF-L XW2Z-0100FF-L XW2Z-0150FF-L XW2Z-0200FF-L XW2Z-0300FF-L XW2Z-0500FF-L XW2Z-0700FF-L XW2Z-1000FF-L Wiring Diagram XG4M-4030-T (mating side) XG4M-4030-T (mating side) 39 40 2 1 37 38 4 3 21 22 20 19 19 20 22 21 3 4 38 37 1 2 40 39 Triangular mark Triangular mark L Note: Wire the connector terminals 1:1 so that the connector terminal numbers coincide. 24 XW2R Models for Keyence PLCs without power supply terminals Phillips screw Ordering Information Appearance I/O Points (Number of poles) Model Dimension A (mm) 32 (34) XW2R-J34GD-K1 130.7 36 (40) XW2R-J40GD-K2 151.7 Ratings and Specifications Rated current Rated voltage Insuration resistance Dielectric strength Ambient operating temperature Applicable Applic wire sizes Stripped able length wires Tightening Details on Crimp Terminals 1A 125 VAC/DC 100MΩ min. (at 500VDC) 500VAC for 1 min (leakage current: 1 mA max.) 0 to 55°C Wiring Terminal Blocks • Using Crimp Terminals (With a Terminal Block with M3 Screws) Terminal Screw Tightening Torque • Use a tightening torque of 0.5 N·m when connecting wires or crimp terminals to the terminal block. Applicable crimp terminals AWG 22 to 16 (round or forked crimp terminals) AWG 26 to 16 (stranded or solid wires) 9 mm Round crimp terminals 3.2 mm dia. 5.8 mm max. Forked crimp terminals 3.2 mm 5.8 mm max. Applicable wires Round crimp terminals 1.25-3 AWG 22 to 16 (0.30 to 1.25 mm2) Forked crimp terminals 1.25Y-3 AWG 22 to 16 (0.30 to 1.25 mm2) 0.5 N·m Dimensions (Unit: mm) The label contents depend on the model. MIL Plug: XG4A-3431 A 50 (44.81) 3.5 7 (Pitch) M3 19.7 5.8 (48.05) Wiring Diagram XW2R-J34GD-K1 MIL Connector XW2R-J40GD-K2 MIL Connector (100) (101) (102) (103) (104) (105) (106) (107) (108) (109) (110) (111) (112) (113) (114) (115) (COM1) (21) (22) (23) (24) (25) (26) (27) (28) (29) (30) (31) (32) (33) (34) (35) (36) (37) (38) (39) (40) (000) (001) (002) (003) (004) (005) (006) (007) (008) (009) (010) (011) (012) (013) (014) (015) (COM0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (20) Terminal Block Terminal Block Label Contents XW2R-J34GD-K1 XW2R-J40GD-K2 25 XW2R Models for Keyence PLCs without power supply terminals Push-in spring Ordering Information Appearance I/O Points (Number of poles) Model Dimension A (mm) 32 (34) XW2R-P34GD-K1 98.5 36 (40) XW2R-P40GD-K2 113.5 Ratings and Specifications Rated current Rated voltage Insuration resistance Dielectric strength Ambient operating temperature Appli cable wires Applicable wire sizes Stripped length Details on Crimp Terminals Applicable Ferrules 1A AC/ DC125V 100MΩ min. (at 500VDC) 500VAC for 1 min (leakage current: 1 mA max.) B • Use ferrules of the lengths and thicknesses specified below.If other lengths or thicknesses are used, connection maynot be possible or it may not be possible to insert or remove the posts. Square ferrules AWG 24 to 14 (ferrules), AWG 28 to 14 (stranded or solid wires) (Outer diameter of insulation must be 4 mm max) AWG28-16: 8 to 10 mm, AWG14: 9 to 10 mm Round ferrules 8-10 mm A Round ferrules Dia. C 8-10 mm • Ferrule Dimensions 0 to 55°C Square ferrules Dimension A (Width) Dimension B (Height) Dimension C (Diameter) 2.7 mm max. The cross-sectional area after crimping must 2 mm max. be 4.8 mm2 or less 2 mm dia. max. (after crimping) Refer to page 28 for information on Square/Round ferrule and use tool. Dimensions (Unit: mm) MIL Plug: XG4A-3431 (44.81) 50 A 100 101 102 103 104 105 000 001 002 003 004 005 The label contents depend on the model. 106 006 107 108 109 110 111 112 113 114 115 COM1 007 008 009 010 011 012 013 014 015 COM0 5 (Pitch) 19.7 (33.1) Wiring Diagram XW2R-P34GD-K1 MIL Connector XW2R-P40GD-K2 MIL Connector (100) (101) (102) (103) (104) (105) (106) (107) (108) (109) (110) (111) (112) (113) (114) (115) (COM1) (21) (22) (23) (24) (25) (26) (27) (28) (29) (30) (31) (32) (33) (34) (35) (36) (37) (38) (39) (40) (000) (001) (002) (003) (004) (005) (006) (007) (008) (009) (010) (011) (012) (013) (014) (015) (COM0) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (20) Terminal Block Terminal Block Label Contents XW2R-P34GD-K1 XW2R-P40GD-K2 26 XW2R Input Device Connectors: XN2 e-CON Connectors For Sensor Relay Connector Appearance Number of poles Model 4 XN2A-1470 Appearance Number of poles Model 4 XN2B-1470 Ratings and Specifications Rated current 3 A/pin (with AWG20 wires), 2 A/pin (with AWG22 wires), 1 A/pin (with AWG24 wires), 0.5 A/pin (with AWG26 or AWG28 wires) Rated voltage 32 VDC Contact resistance 30 mΩ max. (at 20 mV, 100 mA max.) Insuration resistance 103 MΩ min. (at 500VDC) Dielectric strength 1,000 VAC for 60 sec (leakage current: 1 mA max.) Insertion durability 50 times Ambient operating temperature -30 to 75°C ∗ Applicable wires Stranded wire 0.08mm2 (AWG28) to 0.5mm2 (AWG20) (Outer diameter of insulation must be 1.5 mm max) * The operating temperature range is restricted by the maximum operating temperature of the cable. Wiring Procedure Wire Preparation Use the strip gauge on the front panel and strip 7 to 8 mm of the insulation. If you use stranded wires, twist them several times. 3. Insert a flat-blade screwdriver into the release hole and gently reset the lever. You should hear the operation lever reset. Operation lever (white) Release hole 7-8 mm Connection Procedure 1. Press a flat-blade screwdriver into the operation hole until the operation lever locks into place. Flat-blade screwdriver Operation hole 2. Insert the wire all the way into the wire insertion hole. Confirm that the insulation on the wire also enters the wire insertion hole and that the end of the wire has passed through the connection section. Connection section Wire insulation 4. Finally, check the following items. • Make sure the operation lever has been reset. • Check the items given in step 2 again. (Pull lightly on the wire to see if it is held firmly in place.) Wire insertion hole Disconnection Procedure 1. Press in the operation level, confirm that the operation lever is locked into place, and then pull out the wire. 2. After you remove the wire, always reset the operation lever. However, if you are going to connect another wire to the same terminal, you do not need to reset the operation lever and can immediately connect the other wire. Operation lever (white) 27 XW2R Safety Precautions Precautions for Correct Use Wiring Precautions • Do not perform wiring work, remove connectors, or connect connectors while power is being supplied. Electric shock or damage to the device may result. • Double-check all wiring before turning ON the power supply. • After wiring, route the cable so that force is not applied directly to the connections. Wires for Terminal Blocks • Do not damage the cores when stripping the insulation from them. • Always twist stranded wires together before connecting them. • Do not presolder wires. It may not be possible to connect them or remove them. XW2R-P@@ type (Square/Round ferrule) Type of terminal Manufacturer Size AWG24 AI0.25-8@@ AWG22 AI0.34-8TQ AWG20 AI0.5-10WH AI0.5-8WH AWG18 AI0.75-10GY AI0.75-8GY AWG16 AI1.5-10BK AWG14 AI2.5-8BU AWG24 H0.25/12 AWG22 H0.34/12 AWG20 H0.5/14 AWG18 H0.75/14 AWG16 H1.5/14 AWG14 H2.5/15D AWG22AWG16 TGV TC-1.25-9T Phoenix Contact Square ferrule Weidmuller Round ferrule Nichifu Recommend ferrule Recommend crimp tool CRIMFOX6 PZ6 roto NH11 NH32 NH65 Note: @@ of ferrule model is for color (Ex: YE = Yellow) When an electric wire is connected directly (J,E,P type) a Model Strip length “a” XW2R-J@@ 9 mm XW2R-E@@ 7 mm XW2R-P@@ AWG28-16: 8 to 10 mm AWG14: 9 to 10 mm Mounting Units to and Removing Units from DIN Track Mounting Procedure Removal Procedure 2 Press. 1 Hook. 1. Hook the Unit on the DIN Track. 2. Press the Unit onto the DIN Track to secure it. 1. Insert a flat-blade screwdriver into the DIN Track lock. 2. Move the screwdriver like a lever to free the lock. 28 XW2R Connecting Spring cramp Terminals Using Ferrules How to insert wire How to release wire Release hole Terminal holes The wire should be pushed into the terminal block till stopping. Insert the screwdriver into the release hole and pull out the ferrule. Using Stripped Wires Inserting and Removing Wires Insert the screwdriver into the release hole, and the wire should be inserted into the wire insertion hole, and then pull out the screwdriver. Inserting Wires Removing Wires 1. Press the a flat-blade screwdriver diagonally into the release hole. Press at an angle of 10° to 15°. If you press in the screwdriver correctly, you will feel the spring in the release hole. 1. Press the flat-blade screwdriver diagonally into the release hole. Press at an angle of 10° to 15°. If you press in the screwdriver correctly, you will feel the spring in the release hole. Flat-blade screwdriver Release hole 1 Flat-blade screwdriver 1 10 to 15˚ 2. Leave the flat-blade screwdriver pressed into the release hole and insert the stranded wire or the solid wire into the terminal hole. Insert the stranded wire or the solid wire until the stripped portion is no longer visible to prevent shorting. 10 to 15˚ 2. Leave the flat-blade screwdriver pressed into the release hole and pull out the wire. 2 2 Wire Stranded wire/Solid wire 3. Remove the flat-blade screwdriver from the release hole. 3. Remove the flat-blade screwdriver from the release hole. 3 3 29 XW2R Precautions for Safe Use • Do not press the flat-blade screwdriver straight into the release hole. Doing so may break the terminal block. • When you insert a flat-blade screwdriver into a release hole, press it down with a force of 30 N max. Applying excessive force may damage the terminal block. • Do not tilt or twist the flat-blade screwdriver while it is pressed into the release hole. Doing so may break the terminal block. • Make sure that all wiring is correct. • Do not bend the cable forcibly. Doing so may sever the cable. Use tool • Select a use tool from following table. Model Use tool Specialized tool and dimension XW2R-J@@ Phillips screwdriver JIS#2 Flat-blade screwdriver Model XW4Z-00B Head of screwdriver Is 0.4 x 2.5mm max. XW2R-E@@ XW2R-P@@ Flat-blade screwdriver Model XW4Z-00B Bending Radius of Connecting Cables • To prevent damaging the Connecting Cables, use the following minimum bending radii as guidelines. X W 2Z - @ @ @ @ @ End of model number Minimum bending radius BF-L, EE-L, FF-L 66 mm A 67.2 mm EE 83 mm B, D, K, L, N 88 mm For checking electrical continuity • XW2R-E@@ type: There is no elecrical continuity in the screw, Please confirm it at hole for confirming continuity or wiring part. 30 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2016.4 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2016 All Right Reserved.