SIEMENS Product data sheet E87010-A0112-T007-A6-LEN0 Lighting Contactor Class LE Electrically Held 60 Amp, 3 Pole General technical data: Finger-safe (main circuit / control circuit) Degree of pollution Altitude (m) Ambient storage temperature (°C) Ambient operating temperature (°C) Humidity (% non-condensing) Shock resistance at rectangular impulse (g/ms) Shock resistance at sine pulse (g/ms) Rated impulse voltage resistance (kV) Rated insulation voltage (V) Mechanical operating cycles as operating time: of contactor of contactor with additional aux contacts Main circuit: Number of NC / NO main contacts Typical power loss per conductor (W) Off-load operating frequency (cycles per hour) Current ratings: Tungsten (poles per phase) Ballast (poles per phase) General & resistive (poles per phase) Coil ratings: Inrush / sealed power (VA) Coil voltage tolerance factor Coil code 024 Coil code 120 Coil code 208 Coil code 240 Coil code 277 Coil code 347 Coil code 480 Coil code 600 Internal/standard auxiliary contact: Number of NC / NO auxiliary contacts Rating ©2012 Siemens Industry, Inc. Subject to change without prior notice. Siemens Industry, Inc. 5300 Triangle Parkway, Norcross, GA 30092 August, 2012 no / yes 3 2,000 -55 to 80 0 to 40 10 to 95 10 / 5, 5 / 10 15 / 5, 8 / 10 no data no data 10,000,000 10,000,000 0NC / 3NO 2.6 5,000 60A @277V 1p 1ph 60A @480V 2p 1ph 60A @480V 3p 3ph 60A @600V 1p 1ph 60A @600V 2p 1ph 60A @600V 3p 3ph 60A @600V 1p 1ph 60A @600V 2p 1ph 60A @600V 3p 3ph 166 / 12.6 0.8 - 1.1 24VAC 50/60HZ 110VAC 50HZ / 120VAC 60HZ 208VAC 50/60HZ 220VAC 50HZ / 240VAC 60HZ 277VAC 60HZ 347VAC 60HZ 480VAC 60HZ 600VAC 60HZ (must use an external/optional auxiliary contact) NA A5E31166497A-001 Page 1 of 2 Installation/mounting/dimensions: Mounting orientation Type of mounting: screw / DIN rail Height x Width x Depth (mm) Minimum clearance to sides (mm) Minimum clearance to earthed parts (mm) Connection type / torque for main circuit terminals Connection type / torque for control circuit terminals Solid & stranded conductors for main contacts (AWG) Solid & stranded conductors for control circuit (AWG) Conductor type for main and control circuits Short circuit current rating of main circuit: Short circuit current rating Max fuse / circuit breaker (Amp) Certificates: vertical yes / yes 112 x 55 x 115 6 6 screw / 27-40 lb in screw / 7-10 lb in 2x(18-3), 1x(18-2) 2x(18-14) 75°C CU 5kA @ 600V 100 / 80 cULus Dimensions Wiring Diagram ©2012 Siemens Industry, Inc. Subject to change without prior notice. Siemens Industry, Inc. 5300 Triangle Parkway, Norcross, GA 30092 A5E31166497A-001 Page 2 of 2