BETA Low-Voltage Circuit Protection 5SJ4...-.HG.. Miniature Circuit Breakers For worldwide use according to IEC and UL UL standards are used in North America, but also in several other countries. This is of particular importance to European exporters of electrical switchgear equipment for machines who export to the USA, as their products will only be accepted if they meet the relevant UL standards. A wide range of BETA devices comply with UL standards and are therefore suitable for implementation worldwide in both IEC/EN and UL applications within the framework of their specified use. Miniature circuit breakers certified to UL 489 permit use as an all-round solution for protection tasks in distribution boards, control cabinets and control systems to UL 508A as "branch protectors". In particular, they are also certified for the protection of electrical circuits in heating, ventilating and cooling systems (HVAC), as well as for DC applications up to 60 V/125 V in the area of telecommunication applications. A busbar system enables fast and simple installation in the assembly. Benefits • Can be used globally for most applications in residential, non-residential and industrial buildings. This facilitates the planning of plants and enhances export opportunities • The devices can be used according to IEC/EN 60898 and UL 489, which means these devices can be installed virtually anywhere in the world BETA s Miniature Circuit Breakers 5SJ4 miniature circuit breakers according to UL 489 Overview These products cover a wide range of protection tasks, in residential and non-residential buildings, as well as in industry. The tripping characteristics B, C and D to EN/IEC 60898 have been adapted so that they fall in the permissible tripping range to UL 489, as well as for applications at 25 °C and 40 °C. This means that the devices are certified for use according to both standards. The enclosure dimensions of the devices correspond to DIN format. This means that all three device series are suitable for universal use worldwide to IEC or UL standards. The key differences between the three device series are their application in different power supply systems. • • • The terminals are suitable for field wiring. This means that the devices can be installed not only in factory-finished distribution boards and control cabinets, but also on-site in a customer system. 1, 2 and 3-pole busbars in 3 lengths with 6, 12 or 18 terminals are available as accessories for all device series. Connection terminals are available for direct connection at either the busbar; or, the miniature circuit breakers. All unused busbar terminals must be covered with touch protection covers. 5SJ4 … -.HG40: 240/120VAC, 1-pole, "same polarity only", 5SJ4 … -.HG41: 240VAC, 1, 2 and 3-pole, 5SJ4 … -.HG42: 480Y/277VAC, 1, 2 and 3-pole. Benefits • 2 Center feed busbar mounting with a conductor crosssection of up to 50 mm² Miniature Circuit Breakers • End feed miniature circuit breaker mounting for conductor cross-sections up to 35 mm² Technical specifications 5SJ4 ... -.HG40 Standards V AC/DC V DC/pole V AC V AC V DC/1P V DC/2P kA AC kA AC 10 14/101) V AC 250 250/440 3/III Yes Yes IP20, with connected conductors Yes On standard mounting rail Approved to Tripping characteristic Operational voltage • To IEC60898 • To UL 489 and CSAC22.2 No.5-02 min. max. max. max. Rated breaking capacity • Icn to IEC60898-1 • To UL 489 and CSAC22.2 No.5-02 Insulation coordination • Rated insulation voltage • Degree of pollution for overvoltage category Touch protection to EN50274 Handle end position, sealable Degree of protection to EN60529 CFC and silicone-free Mounting Terminals • Combined terminals at both ends • Terminal tightening torque, only for Cu, 60/75°C Conductor cross-sections • Solid and stranded to UL 489 and CSA C22.2 No. 5-02 • Solid and stranded to IEC 60898-1 Mains connection Mounting position Average service life, with rated load Ambient temperature 5SJ4 ... -.HG41 EN 60898; UL 489; CSA C22.2 No.5-02 UL 489; CSA C22.2 No.5-02, UL File Nr. E243414 B, C, D 24 60 440 240/120 60 -- 5SJ4 ... -.HG42 C, D 240 60 125 480Y/277 60 125 14/101) 101) Nm lb/in Yes 3.5 31 AWG 14 ... 4 mm2 0,75...35 Any Any 20000 actuations -25...+45, occasionally +55, max. 95% humidity, storage temperature: -40...+75 6 cycles 60 at 10 ... 150 Hz °C Resistance to climate to IEC 60068-2-30 Resistance to vibrations to IEC 60068-2-6 m/s2 1) For detailed information on rated interrupting ratings, see page 10. Miniature Circuit Breaker Accessories - Preliminary Busbars 5ST3 663 5ST3 664 5ST3 665 Standards Approved to UL 489 UL 489 UL File No. E 5ST3 666-0 Operational voltage • To IEC • To UL 489 V AC V AC 690 480Y/277 and 240 Rated conditional short-circuit current Dielectric strength Surge strength kA kV/mm kV 15 kA with NH3 355A gL/gG 500 V 30 >9,5 Rated current at 40 °C ambient temperature A 115 Insulation coordination • Degree of pollution • Overvoltage category Busbar cross-section 5ST3 666-2 2 III mm² Cu Infeed 16 Any Conductor cross-sections AWG mm² 14 … 2 1.5 … 35 14 … 1 1.5 … 50 Terminals – terminal tightening torque Nm lbs/in 3.5 30 3.5 30 Temperature resistance °C 200 °C – UL94-V0/0.4 mm Miniature Circuit Breakers 3 Selection and ordering data (Dated 10/2008) Characteristic B Rated current In MW A Miniature circuit breakers "same polarity only" 1P, 240 V AC 6 10 13 DT Order No. 1 4 PG PU PS1)/P. unit Unit(s) Unit(s) Weight per PU approx. kg B B C 5SJ4 106-6HG40 5SJ4 110-6HG40 5SJ4 113-6HG40 012 012 012 1 1 1 1 1 1 0.120 0.120 0.120 15 16 20 C C C 5SJ4 118-6HG40 5SJ4 116-6HG40 5SJ4 120-6HG40 012 012 012 1 1 1 1 1 1 0.120 0.120 0.120 25 30 32 C C C 5SJ4 125-6HG40 5SJ4 130-6HG40 5SJ4 132-6HG40 012 012 012 1 1 1 1 1 1 0.120 0.120 0.120 35 40 45 C C C 5SJ4 135-6HG40 5SJ4 140-6HG40 5SJ4 145-6HG40 012 012 012 1 1 1 1 1 1 0.120 0.120 0.120 50 60 63 C C C 5SJ4 150-6HG40 5SJ4 160-6HG40 5SJ4 163-6HG40 012 012 012 1 1 1 1 1 1 0.120 0.120 0.120 PG PU PS1)/P. unit Unit(s) Unit(s) Weight per PU approx. kg Characteristic C 1) Price per PU Characteristic D DT Order No. Order No. 5SJ4 114-7HG40 5SJ4 105-7HG40 5SJ4 101-7HG40 003 003 003 C C C 5SJ4 114-8HG40 5SJ4 105-8HG40 5SJ4 101-8HG40 012 012 012 1 1 1 1 1 1 0.120 0.120 0.120 1.6 2 3 C B B 5SJ4 115-7HG40 5SJ4 102-7HG40 5SJ4 103-7HG40 003 003 003 C C C 5SJ4 115-8HG40 5SJ4 102-8HG40 5SJ4 103-8HG40 012 012 012 1 1 1 1 1 1 0.120 0.120 0.120 4 5 6 B C B 5SJ4 104-7HG40 5SJ4 111-7HG40 5SJ4 106-7HG40 003 003 003 C C C 5SJ4 104-8HG40 5SJ4 111-8HG40 5SJ4 106-8HG40 012 012 012 1 1 1 1 1 1 0.120 0.120 0.120 8 10 13 B B C 5SJ4 108-7HG40 5SJ4 110-7HG40 5SJ4 113-7HG40 003 003 003 C C C 5SJ4 108-8HG40 5SJ4 110-8HG40 5SJ4 113-8HG40 012 012 012 1 1 1 1 1 1 0.120 0.120 0.120 15 16 20 C B B 5SJ4 118-7HG40 5SJ4 116-7HG40 5SJ4 120-7HG40 003 003 003 C C C 5SJ4 118-8HG40 5SJ4 116-8HG40 5SJ4 120-8HG40 012 012 012 1 1 1 1 1 1 0.120 0.120 0.120 25 30 32 B C C 5SJ4 125-7HG40 5SJ4 130-7HG40 5SJ4 132-7HG40 003 003 003 C C C 5SJ4 125-8HG40 5SJ4 130-8HG40 5SJ4 132-8HG40 012 012 012 1 1 1 1 1 1 0.120 0.120 0.120 35 40 45 C C C 5SJ4 135-7HG40 5SJ4 140-7HG40 5SJ4 145-7HG40 003 003 003 C C C 5SJ4 135-8HG40 5SJ4 140-8HG40 5SJ4 145-8HG40 012 012 012 1 1 1 1 1 1 0.120 0.120 0.120 50 60 63 C C C 5SJ4 150-7HG40 5SJ4 160-7HG40 5SJ4 163-7HG40 003 003 003 C C C 5SJ4 150-8HG40 5SJ4 160-8HG40 5SJ4 163-8HG40 012 012 012 1 1 1 1 1 1 0.120 0.120 0.120 You can order this quantity or a multiple thereof. Miniature Circuit Breakers Price per PU PG Rated MW DT current In A Miniature circuit breakers "same polarity only" 1P, 240 V AC 0.3 1 C 0.5 C 1 B Price per PU Characteristic C Rated current In A 1) MW DT Order No. Characteristic D Price per PU PG DT Order No. Price per PU PG PU PS1)/P. unit Unit(s) Unit(s) Weight per PU approx. kg Miniature circuit breakers 1P, 240 V AC 0.3 1 C 0.5 C 1 C 5SJ4 114-7HG41 5SJ4 105-7HG41 5SJ4 101-7HG41 003 003 003 C C C 5SJ4 114-8HG41 5SJ4 105-8HG41 5SJ4 101-8HG41 012 012 012 1 1 1 1 1 1 0.155 0.155 0.155 1.6 2 3 C C C 5SJ4 115-7HG41 5SJ4 102-7HG41 5SJ4 103-7HG41 003 003 003 C C C 5SJ4 115-8HG41 5SJ4 102-8HG41 5SJ4 103-8HG41 012 012 012 1 1 1 1 1 1 0.155 0.155 0.155 4 5 6 C C C 5SJ4 104-7HG41 5SJ4 111-7HG41 5SJ4 106-7HG41 003 003 003 C C C 5SJ4 104-8HG41 5SJ4 111-8HG41 5SJ4 106-8HG41 012 012 012 1 1 1 1 1 1 0.155 0.155 0.155 8 10 13 C C C 5SJ4 108-7HG41 5SJ4 110-7HG41 5SJ4 113-7HG41 003 003 003 C C C 5SJ4 108-8HG41 5SJ4 110-8HG41 5SJ4 113-8HG41 012 012 012 1 1 1 1 1 1 0.155 0.155 0.155 15 16 20 C C C 5SJ4 118-7HG41 5SJ4 116-7HG41 5SJ4 120-7HG41 003 003 003 C C C 5SJ4 118-8HG41 5SJ4 116-8HG41 5SJ4 120-8HG41 012 012 012 1 1 1 1 1 1 0.155 0.155 0.155 25 30 32 C C C 5SJ4 125-7HG41 5SJ4 130-7HG41 5SJ4 132-7HG41 003 003 003 C C C 5SJ4 125-8HG41 5SJ4 130-8HG41 5SJ4 132-8HG41 012 012 012 1 1 1 1 1 1 0.155 0.155 0.155 35 40 45 C C C 5SJ4 135-7HG41 5SJ4 140-7HG41 5SJ4 145-7HG41 003 003 003 C C C 5SJ4 135-8HG41 5SJ4 140-8HG41 5SJ4 145-8HG41 012 012 012 1 1 1 1 1 1 0.155 0.155 0.155 50 C 60 C 63 C Miniature circuit breakers 2P, 240 V AC 0.3 2 C 0.5 C 1 C 5SJ4 150-7HG41 5SJ4 160-7HG41 5SJ4 163-7HG41 003 003 003 C C C 5SJ4 150-8HG41 5SJ4 160-8HG41 5SJ4 163-8HG41 012 012 012 1 1 1 1 1 1 0.155 0.155 0.155 5SJ4 214-7HG41 5SJ4 205-7HG41 5SJ4 201-7HG41 003 003 003 C C C 5SJ4 214-8HG41 5SJ4 205-8HG41 5SJ4 201-8HG41 012 012 012 1 1 1 1 1 1 0.310 0.310 0,310 1.6 2 3 C C C 5SJ4 215-7HG41 5SJ4 202-7HG41 5SJ4 203-7HG41 003 003 003 C C C 5SJ4 215-8HG41 5SJ4 202-8HG41 5SJ4 203-8HG41 012 012 012 1 1 1 1 1 1 0.310 0.310 0,310 4 5 6 C C C 5SJ4 204-7HG41 5SJ4 211-7HG41 5SJ4 206-7HG41 003 003 003 C C C 5SJ4 204-8HG41 5SJ4 211-8HG41 5SJ4 206-8HG41 012 012 012 1 1 1 1 1 1 0.310 0.310 0,310 8 10 13 C C C 5SJ4 208-7HG41 5SJ4 210-7HG41 5SJ4 213-7HG41 003 003 003 C C C 5SJ4 208-8HG41 5SJ4 210-8HG41 5SJ4 213-8HG41 012 012 012 1 1 1 1 1 1 0.310 0.310 0,310 15 16 20 C C C 5SJ4 218-7HG41 5SJ4 216-7HG41 5SJ4 220-7HG41 003 003 003 C C C 5SJ4 218-8HG41 5SJ4 216-8HG41 5SJ4 220-8HG41 012 012 012 1 1 1 1 1 1 0.310 0.310 0,310 25 30 32 C C C 5SJ4 225-7HG41 5SJ4 230-7HG41 5SJ4 232-7HG41 003 003 003 C C C 5SJ4 225-8HG41 5SJ4 230-8HG41 5SJ4 232-8HG41 012 012 012 1 1 1 1 1 1 0.310 0.310 0,310 35 40 45 C C C 5SJ4 235-7HG41 5SJ4 240-7HG41 5SJ4 245-7HG41 003 003 003 C C C 5SJ4 235-8HG41 5SJ4 240-8HG41 5SJ4 245-8HG41 012 012 012 1 1 1 1 1 1 0.310 0.310 0,310 50 60 63 C C C 5SJ4 250-7HG41 5SJ4 260-7HG41 5SJ4 263-7HG41 003 003 003 C C C 5SJ4 250-8HG41 5SJ4 260-8HG41 5SJ4 263-8HG41 012 012 012 1 1 1 1 1 1 0.310 0.310 0,310 You can order this quantity or a multiple thereof. Miniature Circuit Breakers 5 Characteristic C Rated current In A 1) 6 MW DT Order No. Characteristic D Price per PU PG DT Order No. Price per PU PG PU PS1)/P. unit Unit(s) Unit(s) Weight per PU approx. kg Miniature circuit breakers 3P, 240 V AC 0.3 3 C 0.5 C 1 C 5SJ4 314-7HG41 5SJ4 305-7HG41 5SJ4 301-7HG41 003 003 003 C C C 5SJ4 314-8HG41 5SJ4 305-8HG41 5SJ4 301-8HG41 012 012 012 1 1 1 1 1 1 0.465 0.465 0.465 1.6 2 3 C C C 5SJ4 315-7HG41 5SJ4 302-7HG41 5SJ4 303-7HG41 003 003 003 C C C 5SJ4 315-8HG41 5SJ4 302-8HG41 5SJ4 303-8HG41 012 012 012 1 1 1 1 1 1 0.465 0.465 0.465 4 5 6 C C C 5SJ4 304-7HG41 5SJ4 311-7HG41 5SJ4 306-7HG41 003 003 003 C C C 5SJ4 304-8HG41 5SJ4 311-8HG41 5SJ4 306-8HG41 012 012 012 1 1 1 1 1 1 0.465 0.465 0.465 8 10 13 C C C 5SJ4 308-7HG41 5SJ4 310-7HG41 5SJ4 313-7HG41 003 003 003 C C C 5SJ4 308-8HG41 5SJ4 310-8HG41 5SJ4 313-8HG41 012 012 012 1 1 1 1 1 1 0.465 0.465 0.465 15 16 20 C C C 5SJ4 318-7HG41 5SJ4 316-7HG41 5SJ4 320-7HG41 003 003 003 C C C 5SJ4 318-8HG41 5SJ4 316-8HG41 5SJ4 320-8HG41 012 012 012 1 1 1 1 1 1 0.465 0.465 0.465 25 30 32 C C C 5SJ4 325-7HG41 5SJ4 330-7HG41 5SJ4 332-7HG41 003 003 003 C C C 5SJ4 325-8HG41 5SJ4 330-8HG41 5SJ4 332-8HG41 012 012 012 1 1 1 1 1 1 0.465 0.465 0.465 35 40 45 C C C 5SJ4 335-7HG41 5SJ4 340-7HG41 5SJ4 345-7HG41 003 003 003 C C C 5SJ4 335-8HG41 5SJ4 340-8HG41 5SJ4 345-8HG41 012 012 012 1 1 1 1 1 1 0.465 0.465 0.465 50 C 60 C 63 C Miniature circuit breakers 1P, 480Y/277 V AC 0.3 1 0.5 1 5SJ4 350-7HG41 5SJ4 360-7HG41 5SJ4 363-7HG41 003 003 003 C C C 5SJ4 350-8HG41 5SJ4 360-8HG41 5SJ4 363-8HG41 012 012 012 1 1 1 1 1 1 0.465 0.465 0.465 5SJ4 114-7HG42 5SJ4 105-7HG42 5SJ4 101-7HG42 5SJ4 114-8HG42 5SJ4 105-8HG42 5SJ4 101-8HG42 012 012 012 1 1 1 1 1 1 0,155 0,155 0,155 1.6 2 3 5SJ4 115-7HG42 5SJ4 102-7HG42 5SJ4 103-7HG42 5SJ4 115-8HG42 5SJ4 102-8HG42 5SJ4 103-8HG42 012 012 012 1 1 1 1 1 1 0,155 0,155 0,155 4 5 6 5SJ4 104-7HG42 5SJ4 111-7HG42 5SJ4 106-7HG42 5SJ4 104-8HG42 5SJ4 111-8HG42 5SJ4 106-8HG42 012 012 012 1 1 1 1 1 1 0,155 0,155 0,155 8 10 13 5SJ4 108-7HG42 5SJ4 110-7HG42 5SJ4 113-7HG42 5SJ4 108-8HG42 5SJ4 110-8HG42 5SJ4 113-8HG42 012 012 012 1 1 1 1 1 1 0,155 0,155 0,155 15 16 20 5SJ4 118-7HG42 5SJ4 116-7HG42 5SJ4 120-7HG42 5SJ4 118-8HG42 5SJ4 116-8HG42 5SJ4 120-8HG42 012 012 012 1 1 1 1 1 1 0,155 0,155 0,155 25 30 32 5SJ4 125-7HG42 5SJ4 130-7HG42 5SJ4 132-7HG42 5SJ4 125-8HG42 5SJ4 130-8HG42 5SJ4 132-8HG42 012 012 012 1 1 1 1 1 1 0,155 0,155 0,155 35 40 5SJ4 135-7HG42 5SJ4 140-7HG42 --- 1 1 1 1 0,155 0,155 You can order this quantity or a multiple thereof. Miniature Circuit Breakers Characteristic C Rated current In A 1) MW DT Order No. Characteristic D Price per PU PG DT Order No. Price per PU PG PU PS1)/P. unit Unit(s) Unit(s) Weight per PU approx. kg Miniature circuit breakers 2P, 480Y/277 V AC 0.3 2 0.5 1 5SJ4 214-7HG42 5SJ4 205-7HG42 5SJ4 201-7HG42 5SJ4 214-8HG42 5SJ4 205-8HG42 5SJ4 201-8HG42 012 012 012 1 1 1 1 1 1 0,310 0,310 0,310 1.6 2 3 5SJ4 215-7HG42 5SJ4 202-7HG42 5SJ4 203-7HG42 5SJ4 215-8HG42 5SJ4 202-8HG42 5SJ4 203-8HG42 012 012 012 1 1 1 1 1 1 0,310 0,310 0,310 4 5 6 5SJ4 204-7HG42 5SJ4 211-7HG42 5SJ4 206-7HG42 5SJ4 204-8HG42 5SJ4 211-8HG42 5SJ4 206-8HG42 012 012 012 1 1 1 1 1 1 0,310 0,310 0,310 8 10 13 5SJ4 208-7HG42 5SJ4 210-7HG42 5SJ4 213-7HG42 5SJ4 208-8HG42 5SJ4 210-8HG42 5SJ4 213-8HG42 012 012 012 1 1 1 1 1 1 0,310 0,310 0,310 15 16 20 5SJ4 218-7HG42 5SJ4 216-7HG42 5SJ4 220-7HG42 5SJ4 218-8HG42 5SJ4 216-8HG42 5SJ4 220-8HG42 012 012 012 1 1 1 1 1 1 0,310 0,310 0,310 25 30 32 5SJ4 225-7HG42 5SJ4 230-7HG42 5SJ4 232-7HG42 5SJ4 225-8HG42 5SJ4 230-8HG42 5SJ4 232-8HG42 012 012 012 1 1 1 1 1 1 0,310 0,310 0,310 35 40 5SJ4 235-7HG42 5SJ4 240-7HG42 --- 1 1 1 1 0,310 0,310 Miniature circuit breakers 3P, 480Y/277 V AC 0.3 3 0.5 1 5SJ4 314-7HG42 5SJ4 305-7HG42 5SJ4 301-7HG42 5SJ4 314-8HG42 5SJ4 305-8HG42 5SJ4 301-8HG42 012 012 012 1 1 1 1 1 1 0,465 0,465 0,465 1.6 2 3 5SJ4 315-7HG42 5SJ4 302-7HG42 5SJ4 303-7HG42 5SJ4 315-8HG42 5SJ4 302-8HG42 5SJ4 303-8HG42 012 012 012 1 1 1 1 1 1 0,465 0,465 0,465 4 5 6 5SJ4 304-7HG42 5SJ4 311-7HG42 5SJ4 306-7HG42 5SJ4 304-8HG42 5SJ4 311-8HG42 5SJ4 306-8HG42 012 012 012 1 1 1 1 1 1 0,465 0,465 0,465 8 10 13 5SJ4 308-7HG42 5SJ4 310-7HG42 5SJ4 313-7HG42 5SJ4 308-8HG42 5SJ4 310-8HG42 5SJ4 313-8HG42 012 012 012 1 1 1 1 1 1 0,465 0,465 0,465 15 16 20 5SJ4 318-7HG42 5SJ4 316-7HG42 5SJ4 320-7HG42 5SJ4 318-8HG42 5SJ4 316-8HG42 5SJ4 320-8HG42 012 012 012 1 1 1 1 1 1 0,465 0,465 0,465 25 30 32 5SJ4 325-7HG42 5SJ4 330-7HG42 5SJ4 332-7HG42 5SJ4 325-8HG42 5SJ4 330-8HG42 5SJ4 332-8HG42 012 012 012 1 1 1 1 1 1 0,465 0,465 0,465 35 40 5SJ4 335-7HG42 5SJ4 340-7HG42 --- 1 1 1 1 0,465 0,465 You can order this quantity or a multiple thereof. Miniature Circuit Breakers 7 Pin spacing Length DT Order No. MW mm fixed lengths, cannot be cut2) Single-phase For 6 MCB 1P For 12 MCB 1P For 18 MCB 1P 1 1 1 100 205 310 A A A 5ST3 663-0HG 5ST3 663-1HG 5ST3 663-2HG Two-phase For 3 MCB 2P For 6 MCB 2P For 9 MCB 2P 1 1 1 100 205 310 A A A Three-phase For 2 MCBs 3P For 4 MCBs 3P For 6 MCBs 3P 1 1 1 100 205 310 Price per PU PU PS1)/ P.unit Unit(s) Unit(s) Weight per PU approx. kg 012 012 012 1 1 1 10 10 10 0,056 0,112 0,170 5ST3 664-0HG 5ST3 664-1HG 5ST3 664-2HG 012 012 012 1 1 1 10 10 10 0,065 0,137 0,211 A A A 5ST3 665-0HG 5ST3 665-1HG 5ST3 665-2HG 012 012 012 1 1 1 10 10 10 0,067 0,155 0,243 Connection terminals to UL 489 for use only with 5SJ4…-.HG.. Infeed - MCBs 35 mm2 A 5ST3 666-0HG 012 1 10 0,033 Infeed - busbars 50 mm2 A 5ST3 666-2HG 012 1 10 0,034 A 5ST3 666-1HG 012 1 10 0,003 PG Busbars to UL 489 for use with 5SJ4…-.HG.. Touch protection covers for busbars to UL 4892) 3 x 1 pin 8 1) You can order this quantity or a multiple thereof. 2) All unused busbar terminals must be covered with touch protection covers 5ST3666-1HG. Miniature Circuit Breakers 45 110 45 90 I2_13385 1 I2_12749 Dimensional drawings 2 18 6 44 70 18 36 54 6,4 46 70 5SJ4 ...-.HG41 90 45 121 I2_13958 5SJ4 ...-.HG40 18 36 54 6,4 44 70 5SJ4 ...-.HG42 1 1 1 = 17.6 ± 0.2 mm 1 1 = 17.6 ± 0.2 mm I2_14014 1 24 1 35 I2_14010 1 16 15 5ST3 665-0HG 5ST3 665-1HG 5ST3 665-2HG 5ST3 666-1HG 18 I2_14016 46 14 26 51 31 5ST3 664-0HG 5ST3 664-1HG 5ST3 664-2HG I2_14015 5ST3 663-0HG 5ST3 663-1HG 5ST3 663-2HG 16 31 5ST3 666-0HG 5ST3 666-2HG Schematics 5SJ4 1-Pole 2-Pole 3-Pole Miniature Circuit Breakers 9 Configuration UL 489 interrupting ratings Designation Characteristic Current Rated interrupting ratings (operational voltage240 V AC) 5SJ4 …-.HG40 B C C A 6 … 63 0.3 … 40 45 … 63 kA AC 14 14 10 Rated interrupting ratings (operational voltage480Y/277 V AC) kA AC ---- D D C C D 0.3 … 20 25 - 63 0.3 … 40 45 … 63 0.3 … 20 14 10 14 10 14 ------ D C D D 25 … 63 0.3 … 40 0.3 … 20 25 … 32 10 14 14 10 -10 10 10 5SJ4 …-.HG41 5SJ4 …-.HG42 Power loss Rated current IN A 0.3 0.5 1 Characteristic B Ri mΩ ---- Pv W ---- Characteristic C Ri mΩ 12900 4900 1650 Pv W 1.2 1.2 1.7 Characteristic D Ri mΩ 12600 4600 1480 Pv W 1.1 1.2 1.5 1.6 2 3 ---- ---- 620 440 197 1.6 1.8 1.8 570 435 190 1.5 1.8 1.7 4 5 6 --85 --3.1 115 115 74 1.8 2.9 2.7 100 100 73 1.6 2.5 2.6 8 10 13 -16.5 11.7 -1.7 2.0 40 13.5 10.2 2.6 1.4 1.7 39 11.9 10.2 2.5 1.2 1.7 15 16 20 8.5 8.5 6.7 1.9 2.2 2.7 7.8 7.8 5.5 1.8 2.0 2.2 7.7 7.7 5.5 1.7 2.0 2.2 25 30 32 4.3 3.4 3.4 2.7 3.1 3.5 4.2 3.5 3.5 2.6 3.2 3.6 4.2 3.0 3.0 2.6 2.7 3.1 35 40 45 2.8 2.8 2.8 3.4 4.5 5.7 2.8 2.8 2.7 3.4 4.5 5.5 2.7 2.5 2.5 3.3 4.0 5.1 50 60 63 2.1 1.7 1.7 5.3 6.1 6.7 2.1 1.7 1.7 5.0 6.1 6.7 2.0 1.7 1.7 5.0 6.1 6.7 Siemens AG Industry Sector Building Technologies Electrical Installation Technology P.O. Box 10 09 53 93009 REGENSBURG GERMANY www.siemens.com/beta Subject to change without notice Order No.: E86060-K8220-E470-A2-7600 PI 0808 1. SB 10 En / 803076 © Siemens AG 2008 The information provided in this brochure contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.