RS401

Product Overview
RUGGEDCOM RS401
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet
Switch, 128-bit Encryption
The RUGGEDCOM RS401 from Siemens is a utility grade
4 port serial device server with an integrated, fully managed
4 port Ethernet switch and an optional V.90 modem. Based
on the popular RS400, the RS401 includes all the same
functionality in a more compact design that is particularly
suited for panel mount locations or installations with tight
space restrictions. The RS401 is able to interconnect multiple
types of intelligent electronic devices (IEDs) that have different
methods of communications. Using the RS400 results in
fewer connectivity devices (which reduces overall system
costs) and also extends the useful life of existing legacy IEDs,
which minimizes capital expenditures for new equipment.
Designed to operate reliably in electrically harsh and climatically
demanding environments, the RS401 provides a high level
of immunity to electromagnetic interference and heavy
electrical surges typical of environments found in electric utility
substations, curb side traffic control cabinets, and factory floors.
An operating temperature range of -40°C to +85°C coupled with
hazardous location compliance (Class 1 Division 2), optional
conformal coating and a galvanized steel enclosure, allows the
RS401 to be placed in almost any location.
Options include 24VDC, 48VDC, 88-300VDC, and
85-264VAC, allowing for great installation flexibility.
The embedded Rugged Operating System (ROS) provides
advanced cyber security features and comprehensive
networking functions such as Enhanced Rapid Spanning
Tree (eRSTP), Port Rate Limiting, and a full array of intelligent
functionality for high network availability and manageability.
Coupled with ruggedness and durability that is designed in
from the onset, the RS400 is ideal for creating mission critical,
real-time, control applications where high reliability and
availability is of paramount importance.
All RUGGEDCOM products are backed by a five year warranty
and unsurpassed technical support.
The RS401 also includes an industrially rated integrated
power supply that can support a wide range of power options
suitable for multiple industries and worldwide operability.
usa.siemens.com/ruggedcom
Features and Benefits
Serial Device Server
■ Fully compliant EIA/TIA RS485, RS422, RS232 serial
ports (software selectable) – DB9, RJ45, Phoenix
style connectors
■ 4 serial port interfaces
■ Serial fiber interface (ST) option
■ Raw socket mode allows conversion of any serial protocol
■ Converts DNP3.0 to DNP over UDP/TCP
■ Transmit serial data over an IP network
■ Support for Modbus TCP, DNP3, WIN, TIN, and Microlock serial protocols
■ Baud rates up to 230 kbps
■ Point-to-point and multi-point modes
■ Convert Modbus RTU to Modbus TCP
■ Supports multiple Modbus masters
Ethernet Ports
■ Integrated Ethernet Switch – up to 4 ports
■ High performance and throughput Ethernet switching
■ Full IEEE 802.3, IEEE 802.3u, IEEE 802.3x compliance
■ Non-blocking, store and forward switching
■ 10/100BaseTX, 10BaseFL, 100BaseFX options
Cyber Security Features
■ Multi-level user passwords
■ SSH/SSL/SFTP (128-bit encryption)
■ Enable/disable ports, MAC based port security
■ Port based network access control (802.1x)
■ VLAN (802.1Q) to segregate and secure network traffic
■ RADIUS centralized password management
■ SNMPv3 authentication and 56-bit encryption
Rugged Rated for Reliability in Harsh
Environments
■ Immunity to EMI and heavy electrical surges
- Meets IEEE 1613 (electric utility substations)
- Exceeds IEC 61850-3 (electric utility substations)
2
RUGGEDCOM RS401
- Exceeds IEC 61800-3 (variable speed drive systems)
- Exceeds IEC 61000-6-2 (generic industrial)
- Exceeds NEMA TS-2 (traffic control equipment)
■ Fully independent 2kV (RMS) isolated serial ports
■ -40°C to +85°C operating temperature (no fans)
■ 18 AWG galvanized steel enclosure
Rugged Operating System (ROS) Features
■ Simple plug and play operation – automatic learning,
negotiation, and crossover detection
■ MSTP (802.1Q – 2005, formerly 802.1s
■ RSTP (802.1D-2004) and Enhanced Rapid Spanning Tree
(eRSTP) network fault recovery (<5ms)
■ Quality of Service (802.1p) for real-time traffic
■ VLAN (802.1Q) with double tagging and GVRP support
■ Link aggregation (802.3ad)
■ IGMP snooping for multicast filtering
■ Port rate limiting and broadcast storm limiting
■ Port configuration, status, statistics, mirroring, security
■ SNTP time synchronization (client and server)
Universal Power Supply Options
■ Fully integrated power supply (no external adaptors)
■ Popular low-voltage DC ranges: 24VDC (10-36VDC) or
48VDC (36-59VDC)
■ Universal high-voltage range: 88-300VDC or 85-264VAC
■ CSA/UL 60950 safety approved to +85°C
■ Screw connection terminal blocks ensure reliable
maintenance free connections
Remote Dial Up Access
■ Integrated V.90 modem and PPP server
■ Provides remote access to serial devices and Ethernet LAN
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch, 128-bit Encryption
RUGGEDCOM RS401
Mounting Options
Integrated V.90 Modem
Failsafe Output Relay
„Panel or DIN Rail
„ 56 kbps
„ 0.4A @ 120VAC
„2 A @ 30VDC
Integrated Power Supply
„ Universal high-voltage range:
88-300VDC or 85-264VAC
„Popular low voltage DC ranges:
24VDC (10-36VDC)
48VDC (36-59VDC)
Serial Ports
„ 4 - RS232/RS422/RS485
„DB9, RJ45, or screw terminal
connectors
„2 kV Isolation per Port
Ethernet Ports
„4 -Port Ethernet Switch
„Fiber and Copper Ports
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch, 128-bit Encryption
RUGGEDCOM RS401
3
ROS Features
Serial IP Encapsulation
Many ‘legacy’ devices (RTU, PLC, IED, etc.) only support
serial communications via RS232, RS422 or RS485. ROS
encapsulates the serial data within a TCP connection
allowing these devices to be reached via an IP network.
A wide range of baud rates, frame packetization options,
and diagnostics allows any serial protocol to function. The
RS400 has specific support for the following serial protocols:
■ Raw socket serial encapsulation
■ Modbus TCP (client and server)
■ DNP 3
■ WIN and TIN
■ Microlok
Modbus TCP
The Modbus protocol is ubiquitous in the industrial control
and automation world. ROS converts Modbus RTU master/
slave serial data packets to Modbus TCP client/server
packets for transmission over an IP network. This allows
communications to Modbus RTU slaves via Ethernet and
allows multiple masters to poll the same slave device.
Cyber Security
Cyber security is an urgent issue in many industries where
advanced automation and communications networks play
a crucial role in mission critical applications and where high
reliability is of paramount importance. Key ROS features that
address security issues at the local area network
level include:
■ Passwords – Multi-level user passwords secures switch
against unauthorized configuration
■ SSH / SSL – Extends capability of password protection
to add 128-bit encryption of passwords and data as they
cross the network
■ Enable/Disable ports – Capability to disable ports so
that traffic can not pass
■ 802.1Q VLAN – Provides the ability to logically segregate
traffic between predefined ports on switches
■ MAC based port security – The ability to secure ports
on a switch so only specific Devices / MAC addresses
can communicate via that port
■ 802.1x Port based network access control – The ability
to lock down ports on a switch so that only authorized
clients can communicate via this port
■ RADIUS – authentication service using MD5 hash and
providing centralized password management
■ SNMPv3 – encrypted authentication access security and data encryption (CBC-DES with 56-bit encryption key)
■ Secure socket layer – Web-based management using
SSL with data encryption (128-bit encryption key)
■ RSA – 1024 bit key for key management and key
exchange
■ TACACS+ – Terminal Access Control and Accounting Services. Client provides encrypted authentication
and authorization
■ Point to Point (PPP) – using CHAP (MD5 Hash)
authentication service
■ SFTP – Secure File Transfer Protocol using SSH encryption
4
RUGGEDCOM RS401
The ROS cyber security features are included to help address
the various industry specific security standards such as
NERC CIP, ISA S99, AGA 12, IEC 62443, ISO 17799:2005
and PCSRF SPP-ICS.
Enhanced Rapid Spanning Tree Protocol
(eRSTP)
RUGGEDCOM eRSTP allows the creation of fault-tolerant
ring and mesh Ethernet networks that incorporate
redundant links that are ‘pruned’ to prevent loops. eRSTP
yields worst-case fault recovery 1 of 5ms times the ‘bridge
diameter’ and allows rings of up to 160 switches. For
example, a ring of ten switches will have fault recovery
times under 50ms. eRSTP implements both STP and RSTP
to ensure interoperability with commercial switches
unlike other proprietary ‘ring’ solutions.
Quality of Service (IEEE 802.1p)
Some networking applications such as real-time control
or VoIP (voice over IP) require predictable arrival times for
Ethernet frames. Switches can introduce latency in times
of heavy network traffic due to the internal queues that
buffer frames and then transmit on a first come first serve
basis. ROS supports ‘Class of Service’ in accordance with
IEEE 802.1p that allows time critical traffic to jump ahead
to the front of the queue thus minimizing latency and
reducing jitter to allow such demanding applications to
operate correctly. ROS allows priority classification by
port, tags, MAC address, and IP type of service (ToS). A
configurable “weighted fair queuing” algorithm controls
how frames are emptied from the queues.
VLAN (IEEE 802.1Q)
Virtual local area networks (VLAN) allow the segregation
of a physical network into separate logical networks with
independent broadcast domains. A measure of security is
provided since hosts can only access other hosts on the
same VLAN and traffic storms are isolated. ROS supports
802.1Q tagged Ethernet frames and VLAN trunks. Port
based classification allows legacy devices to be assigned to
the correct VLAN. GVRP support is also provided to simplify
the configuration of the switches on the VLAN.
Link Aggregation (802.3ad)
The link aggregation feature provides the ability to
aggregate several Ethernet ports into one logical link (port
trunk) with higher bandwidth. This provides an inexpensive
way to set up a high speed backbone to improve network
bandwidth. This feature is also known as “port trunking,”
“port bundling,” “port teaming,” and “Ethernet trunk.”
1 eRSTP fault recovery times may be approximated as follows:
For 100 Mbps, fault recovery performance is <5ms/hop
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch, 128-bit Encryption
ROS Features
IGMP Snooping
Broadcast Storm Filtering
ROS uses IGMP snooping (Internet Group Management
Protocol v1, v2 and v3) to intelligently forward or filter
multicast traffic streams (e.g. MPEG video) to or from
hosts on the network. This reduces the load on network
trunks and prevents packets from being received on
hosts that are not involved. ROS has a very powerful
implementation of IGMP snooping that:
■ Can be enabled on a per VLAN basis
■ Detects and filters all multicast streams regardless of whether subscribers exist
■ Supports “router-less” operation by supporting an
“active” mode
■ Restores traffic streams immediately after an RSTP
topology change
Broadcast storms wreak havoc on a network and can cause
attached devices to malfunction. This could be disastrous on
a network with mission critical equipment. ROS limits this by
filtering broadcast frames with a user-defined threshold.
SNMP (Simple Network Management Protocol)
SNMP provides a standardized method for network
management stations to interrogate devices from different
vendors. SNMP versions supported by ROS are v1, v2c, and
v3. SNMPv3, in particular, provides security features such as
authentication, privacy with data encryption (CBC-DES with
56-bit encryption key) and access control not present in
earlier SNMP versions. ROS also supports numerous standard
MIBs (Management Information Base) allowing for easy
integration with any network management system (NMS).
A feature of SNMP supported by ROS is the ability to
generate “traps” upon system events. RUGGEDCOM NMS, the
RUGGEDCOM management solution, can record traps from
multiple devices providing a powerful network troubleshooting
tool. It also provides a graphical visualization of the network
and is fully integrated with all RUGGEDCOM products.
SCADA and Industrial Automation
ROS contains features that optimize network performance
and simplify switch management based on the unique
requirements found in SCADA and industrial automation
applications. Features such as Modbus TCP management
for retrieval of switch data using the ubiquitous Modbus
protocol and DHCP Option 82, a Rockwell Automation ODVA
requirement for IP address assignment based on the location
of the end device, provide capabilities not found in typical
“commercial” or “office grade” Ethernet switches.
Port Based Network Access Control (802.1x)
ROS supports the IEEE 802.1x standard that defines a
mechanism for port-based network access control which
provides a means of authenticating and authorizing
devices attached to LAN ports.
Port Rate Limiting
ROS supports configurable rate limiting per port to limit
unicast and multicast traffic. This can be essential to managing
precious network bandwidth for service providers. It also
provides edge security for denial of service (DoS) attacks.
Port Mirroring
ROS can be configured to duplicate all traffic on one port to
a designated mirror port. When combined with a network
analyzer, this can be a powerful troubleshooting tool.
Port Statistics and RMON (Remote Monitoring)
ROS provides continuously updating statistics per port that
provide both ingress and egress packet and byte counters as
well as detailed error figures. Also provided is full support
for the RMON statistics, history, alarms, and event groups.
RMON allows for very sophisticated data collection, analysis
and detection of traffic patterns.
Event Logging and Alarms
ROS records all significant events to a non-volatile system
log allowing forensic troubleshooting. Events include link
failure and recovery, unauthorized access, broadcast storm
detection, and self-test diagnostics among others. Alarms
provide a snapshot of recent events that have yet to be
acknowledged by the network administrator. An external
hardware relay is de-energized during the presence of critical
alarms allowing an external controller to react if desired.
HTML Web Browser and Telnet/SSH User
Interfaces
ROS provides a simple, intuitive user interface for configuration
and monitoring via a standard graphical web browser or via
Telnet/SSH. All system parameters include detailed on-line
help to make setup a breeze. ROS, presents a common look
and feel and standardized configuration process allowing
easy migration to other RUGGEDCOM managed products.
Configuration via ASCII Text File
All configuration parameters are stored in an ASCII formatted
text file that can easily be transferred via TFTP, SFTP or
Xmodem. The configuration file can be saved for backup
purposes and easily manipulated by a text editor. The same
text file can be downloaded to the switch at a later date in
order to re-configure or restore a previous configuration.
Command Line Interface (CLI)
A command line interface can be used in conjunction with
remote shell to automate data retrieval, configuration
updates, and firmware upgrades. A powerful SQL-like
capability allows expert users the ability to selectively retrieve
or manipulate any parameters the device has to offer.
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch, 128-bit Encryption
RUGGEDCOM RS401
5
EMI and Environmental Type Tests
IEC 61850-3 EMI Type Tests
Test
Description
IEC 61000-4-2
ESD
IEC 61000-4-3
Radiated RFI
IEC 61000-4-4
Burst (fast transient)
IEC 61000-4-5
Surge
IEC 61000-4-6
Induced (conducted) RFI
IEC 61000-4-8
Magnetic field
IEC 61000-4-29
Voltage dips and interrupts
IEC 61000-4-11
IEC 61000-4-12
Damped oscillatory
IEC 61000-4-16
Mains frequency voltage
IEC 61000-4-17
Ripple on D.C. power supply
IEC 60255-5
Dielectric strength
IEC 60255-5
H.V. impulse
Test Levels
Severity Levels
Signal ports
D.C. power ports
A.C. power ports
Signal ports
D.C. power ports
D.C. power ports
Signal ports
D.C. power ports
A.C. power ports
Signal ports
D.C. Power ports
A.C. Power ports
+/- 8kV
+/- 15kV
20 V/m
+/- 4kV @ 2.5kHz
+/- 4kV
+/- 4kV
+/- 4kV
+/- 4kV line-to-earth, +/- 2kV line-to-line
+/- 4kV line-to-earth, +/- 1kV line-to-line
+/- 4kV line-to-earth, +/- 2kV line-to-line
10V
10V
10V
10V
40 A/m continuous, 1000 A/m for 1 s
30% for 0.1s, 60% for 0.1s, 100% for 0.05s
30% for 1 period, 60% for 50 periods
100% for 5 periods, 100% for 50 periods 2
2.5kV common, 1kV diff. mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
30V Continuous, 300V for 1s
30V Continuous, 300V for 1s
10%
2kVac (Fail-safe relay output)
1.5V DC
2kVac
5kV (Fail-safe relay output)
5kV
5kV
4
4
X
X
4
4
4
4
3
4
3
3
3
3
N/A
N/A
N/A
N/A
3
3
3
4
4
3
N/A
N/A
N/A
N/A
N/A
N/A
Enclosure contact
Enclosure air
Enclosure ports
Signal ports
D.C. power ports
A.C. power ports
Earth ground ports 3
Signal ports
D.C. power ports
A.C. power ports
Signal ports
D.C. power ports
A.C. power ports
Signal ports
D.C. power ports
A.C. power ports
Test Levels
+/-8kV
+/-15kV
35 V/m
+/- 4kV @ 2.5kHz
+/- 4kV
+/- 4kV
+/- 4kV
2.5kV common mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
2kVac (Fail-safe relay output)
1.5kV DC
2kVac
5kV (Fail-safe relay output)
5kV
5kV
Severity Levels
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Enclosure contact
Enclosure air
Enclosure ports
Signal ports
D.C. power ports
A.C. power ports
Earth ground ports 3
Signal ports
D.C. power ports
A.C. power ports
Signal ports
D.C power ports
A.C. power ports
Earth ground ports 3
Enclosure ports
D.C. power ports
A.C. power ports
IEEE 1613 (C37.90.x) EMI Immunity Type Tests
Test
Description
IEEE C37.90.3
ESD
IEEE C37.90.2
Radiated RFI
IEEE C37.90.1
Fast transient
IEEE C37.90.1
Oscillatory
IEEE C37.90
Dielectric strength
IEEE C37.90
H.V. impulse
Environmental Type Tests
Test
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
Description
Cold temperature
Dry heat
Humidity (damp heat, cyclic)
Vibration
Shock
Test Ad
Test Bd
Test Db
Test Fc
Test Ea
Test Levels
-40°C, 16 hours
+85°C, 16 hours
95% (non-condensing), 55°C , 6 cycles
2g @ (10 - 150) Hz
30g @ 11mS
Security Levels
N/A
N/A
N/A
Class 2
Class 2
1 RUGGEDCOM
specified severity levels.
2 refers to “Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are
very high, (e.g. shipboard application and for severe transportation conditions”).
3 Only applicable to functional earth connections separated from the safety earth connection.
2 Class
6
RUGGEDCOM RS401
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch, 128-bit Encryption
Technical Specifications
Power Supply
■ Power consumption: 8W Max
■ 24VDC: 10-36VDC (max, 0.4A
■ 48VDC: 36-59VDC (max), 0.2A
■ HI voltage AC/DC: 88-300VDC or 85-264VAC, 0.1A
Critical Alarm Relay
■ Form-C failsafe contact relay:
1A@30VDC
Physical Dimensions
■ Height: 3.5” (89mm)
■ Width: 6.76” (172mm)
■ Depth: 7.42” (188mm)
■ Weight: 4.15lbs (1.9 kg)
■ Ingress protection: IP40 (1mm objects)
■ Enclosure: 18 AWG galvanized steel enclosure
■ Mounting: DIN rail or panel mounted
Switch Properties
■ Switching method: Store and forward
■ Switching latency: 5 μs (100Mbps)
■ Switching bandwidth: 1.2 Gbps
■ MAC addresses: 2048
■ MAC address table size: 16kbytes
■ Priority Queues: 4
■ Frame buffer memory: 1-Mbit
■ Simultaneous VLANs: 255
■ VLAN ID Range: 1 to 4094
■ IGMP multicast groups: 256
Regulatory Approvals
■ ISO: Designed and manufactured using an ISO9001:
2000 certified quality program
■ CE marking
■ Emissions: FCC Part 15 (Class A), EN55022 (CISPR22 Class A)
■ Safety: cCSAus (Compliant with CSA C22.2 No. 60950,
UL 60950, EN60950)
■ Laser eye safety (FDA/CDRH): Complies with 21 CFR
Chapter 1, Subchapter J
Network Management
■ HTTPS graphical web-based, SSL (128-bit encryption)
■ SNMP v1, v2c, v3 (56-bit encryption)
■ Telnet, VT100, SSH/SFTP (128-bit encryption)
■ Command Line Interface (CLI)
■ RSA Key Management (1024 bit key)
■ Authentication and Accounting – TACACS+ (encrypted),
RADIUS client, PPP
Warranty
■ 5 Years – Applicable to design and manufacturing related
product defects
EMI Immunity and Environmental Compliance
■IEC 61000-6-2 Industrial (Generic)
■IEC 61800-3 Industrial (Variable Speed Drive Systems)
■ IEC 61850-3 Electric Utility Substations
■ IEEE 1613 Electric Utility Substations
■ NEMA TS 2 Traffic Control Equipment
■Hazardous Location Class 1, Division 2
IEEE Compliance
■802.3-10BaseT
■802.3u-100BaseTX, 100BaseFX
■802.3x-Flow Control
■ 802.3D-MAC Bridges
■802.1D-Spanning Tree Protocol
■802.1p-Class of Service
■802.1Q-VLAN Tagging
■802.1w-Rapid Spanning Tree Protocol
■ 802.1x-Port Based Network Access Control
■802.1Q-2005 (formerly 802.1s) MSTP
IETF RFC Compliance
■RFC768-UDP
■ RFC783-TFTP
■RFC791-IP
■RFC792-ICMP
■RFC793-TCP
■RFC826-ARP
■RFC854-Telnet
■RFC894-IP over Ethernet
■RFC1112-IGMP v1
■RFC1519-CIDR
■RFC1541-DHCP (client)
■RFC2030-SNTP
■RFC2068-HTTP
■RFC2236-IGMP v2
■RFC2284-EAP
■RFC2475-Differentiated Services
■RFC2865-RADIUS
■RFC3376 IGMP v3
■RFC3414-SNMPv3-USM
■RFC3415-SNMPv3-VACM
IETF SNMP MIBS
■ RFC1493-BRIDGE-MIB
■RFC1907-SNMPv2-MIB
■RFC2012-TCP-MIB
■RFC2013-UDP-MIB
■RFC2578-SNMPv2-SMI
■RFC2579-SNMPv2-TC
■ RFC2819-RMON-MIB
■RFC2863-IF-MIB
■draft-ietf-bridge-rstpmib-03-BRIDGE-MIB
■draft-ietf-bridge-bridgemib-smiv2-03-RSTP-MIB
■IANAifType-MIB
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch, 128-bit Encryption
RUGGEDCOM RS401
7
Fiber Specifications and Dimension Drawings
Fiber Optical Specifications
Parameter
Fiber Port Type
RUGGEDCOM RS401
Installation
Guide
Mode
10BaseFL
100BaseFX
Multimode
Multimode
Chapter 5
Dimension Drawings
Singlemode
Connectors
ST
MTRJ, ST, SC
LC, SC
Typical dist. (km)
2
2
20
50
Dimension Drawings
90
Optical wavelength (nm)
820
1310
1310
1310
1310
Cable size core/cladding (um)
50/125 or 62./125
50/125 or 62./125
8/125 or 9/125
8/125 or 9/125
8/125 or 9/125
TX power (dBm)
-34.4
-15.7
-15.5
-2.5
2.5
RX sensitivity (dBm)
-8.2
-33.5
-32
-37
-39
Typical budget (dB)
22
17
16.5
34.5
41.5
NOTE
Longer segment lengths dependent on fiber specifications. Consult factory for further details.
All dimensions are in millimeters, unless otherwise stated.
8.2
151.9
127.0
174.0
188.5
10.2
8.2
22.1
88.6
172.0
Figure 20: Overall Dimensions
Overall dimensions
All dimensions are in millimeters, unless otherwise stated.
8
RUGGEDCOM RS401
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch, 128-bit Encryption
Chapter 5
RUGGEDCOM RS401
Dimension Drawings
Installation Guide
Dimension Drawings
125.7
12.7
134.4
4.1
8.1
Figure 21: Panel and Din Rail Mount Dimensions
Panel and DIN rail mount dimensions
All dimensions are in millimeters, unless otherwise stated.
26
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch, 128-bit Encryption
RUGGEDCOM RS401
9
Order Code
6GK6040-1AT2 - ____ - 0 - ________ - A - ______ - Z - ______ +
PS1
Mount
MOD
E1/E2
PS: Power Supply
____ + ____
SP
MP
SP: Serial Port Options
1 = 24VDC (12-36VDC)
2 = 48VDC (36-59VDC)
3 = 87-264VAC or 88-300VDC
B00 = 4 x RS232 via DB9
B01 = 4 x RS485 via 3 POS screw terminals
B02 = 4 x RS232/RS422/RS485 via DB9
B03 = 4 x RS232/RS422/RS485 via RJ45
Mount: Mounting Options
A = No mounting hardware
B = Front panel mount with DIN screw points
C = Side panel mount with DIN screw points
MOD: Manufacturing Modifications
0 = None
1 = Conformal coating
E1/E2: Addition Ethernet Ports 1 & 2 Options 1
A00 = 100FX Singlemode LC, Long Reach 90km
A01 = 10FL Multimode ST, 820nm, 2km
A02 = 100FX Singlemode SC, Long Reach 90km
A03 = 100FX Singlemode LC, Intermediate Reach 50km
A04 = 100FX Multimode MTRJ
A05 = 100FX Multimode LX
A06 = 100FX Multimode SC
A07 = 100FX Multimode ST
A08 = 100FX Multimode LC 100FX Singlemode LC,
Standard 20km
A09 = 100FX Singlemode LC, Standard 20km
A10 = 100FX Singlemode SC, Standard 20km
A11 = 100FX Singlemode SC, Intermediate Reach 50 km
A12 = 10/100BaseTX RJ45
A13 = 100FX Singlemode ST, Standard 20km
MP: Modem Port Options
C00 = No Modem
C01 = V.90 (56Kbps) Modem
Notes:
1 Ports 1 & 2 must have the same type of connector ie. RJ45, MTRJ, ST, SC, LCW.
All units come standard with 2 10/100Tx RJ45 Ethernet ports
(on Ports 3 & 4).
Example Order Codes
6GK6040-1AT21-0AA1-Z A04+B02+C00
24VDC power supply, no Mounting Hardware, Conformal Coating,
100FX Multimode MTRJ, 4 x RS232/RS422/RS485 via DB9, no modem
6GK6040-1AT23-0BA0-Z A02+B00+C01
87-264VAC or 88-300VDC, Front panel mount with DIN screw points,
100 FX Singlemode SC, Long Reach 90km, 4 x RS232 via DB9, V.90(56Kbps) Modem
10
RUGGEDCOM RS401
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch, 128-bit Encryption
Siemens Industry, Inc.
5300 Triangle Parkway
Norcross, GA 30092
1-800-241-4453
[email protected]
usa.siemens.com/ruggedcom
Subject to change without prior notice.
All rights reserved.
©2015 Siemens Industry, Inc.
The information provided in this brochure contains descriptions or
characteristics of performance which in case of actual use do not
always apply as described or which may change as a result of
further development of the products. An obligation to provide
the respective characteristics shall only exist if expressly agreed in
the terms of contract. Availability and technical specifications are
subject to change without notice.
All product designations may be trademarks or product names
of Siemens or supplier companies whose use by third parties
for their own purposes could violate the rights of the owners.