Product Overview RUGGEDCOM RS401 4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch, 128-bit Encryption The RUGGEDCOM RS401 from Siemens is a utility grade 4 port serial device server with an integrated, fully managed 4 port Ethernet switch and an optional V.90 modem. Based on the popular RS400, the RS401 includes all the same functionality in a more compact design that is particularly suited for panel mount locations or installations with tight space restrictions. The RS401 is able to interconnect multiple types of intelligent electronic devices (IEDs) that have different methods of communications. Using the RS400 results in fewer connectivity devices (which reduces overall system costs) and also extends the useful life of existing legacy IEDs, which minimizes capital expenditures for new equipment. Designed to operate reliably in electrically harsh and climatically demanding environments, the RS401 provides a high level of immunity to electromagnetic interference and heavy electrical surges typical of environments found in electric utility substations, curb side traffic control cabinets, and factory floors. An operating temperature range of -40°C to +85°C coupled with hazardous location compliance (Class 1 Division 2), optional conformal coating and a galvanized steel enclosure, allows the RS401 to be placed in almost any location. Options include 24VDC, 48VDC, 88-300VDC, and 85-264VAC, allowing for great installation flexibility. The embedded Rugged Operating System (ROS) provides advanced cyber security features and comprehensive networking functions such as Enhanced Rapid Spanning Tree (eRSTP), Port Rate Limiting, and a full array of intelligent functionality for high network availability and manageability. Coupled with ruggedness and durability that is designed in from the onset, the RS400 is ideal for creating mission critical, real-time, control applications where high reliability and availability is of paramount importance. All RUGGEDCOM products are backed by a five year warranty and unsurpassed technical support. The RS401 also includes an industrially rated integrated power supply that can support a wide range of power options suitable for multiple industries and worldwide operability. usa.siemens.com/ruggedcom Features and Benefits Serial Device Server ■ Fully compliant EIA/TIA RS485, RS422, RS232 serial ports (software selectable) – DB9, RJ45, Phoenix style connectors ■ 4 serial port interfaces ■ Serial fiber interface (ST) option ■ Raw socket mode allows conversion of any serial protocol ■ Converts DNP3.0 to DNP over UDP/TCP ■ Transmit serial data over an IP network ■ Support for Modbus TCP, DNP3, WIN, TIN, and Microlock serial protocols ■ Baud rates up to 230 kbps ■ Point-to-point and multi-point modes ■ Convert Modbus RTU to Modbus TCP ■ Supports multiple Modbus masters Ethernet Ports ■ Integrated Ethernet Switch – up to 4 ports ■ High performance and throughput Ethernet switching ■ Full IEEE 802.3, IEEE 802.3u, IEEE 802.3x compliance ■ Non-blocking, store and forward switching ■ 10/100BaseTX, 10BaseFL, 100BaseFX options Cyber Security Features ■ Multi-level user passwords ■ SSH/SSL/SFTP (128-bit encryption) ■ Enable/disable ports, MAC based port security ■ Port based network access control (802.1x) ■ VLAN (802.1Q) to segregate and secure network traffic ■ RADIUS centralized password management ■ SNMPv3 authentication and 56-bit encryption Rugged Rated for Reliability in Harsh Environments ■ Immunity to EMI and heavy electrical surges - Meets IEEE 1613 (electric utility substations) - Exceeds IEC 61850-3 (electric utility substations) 2 RUGGEDCOM RS401 - Exceeds IEC 61800-3 (variable speed drive systems) - Exceeds IEC 61000-6-2 (generic industrial) - Exceeds NEMA TS-2 (traffic control equipment) ■ Fully independent 2kV (RMS) isolated serial ports ■ -40°C to +85°C operating temperature (no fans) ■ 18 AWG galvanized steel enclosure Rugged Operating System (ROS) Features ■ Simple plug and play operation – automatic learning, negotiation, and crossover detection ■ MSTP (802.1Q – 2005, formerly 802.1s ■ RSTP (802.1D-2004) and Enhanced Rapid Spanning Tree (eRSTP) network fault recovery (<5ms) ■ Quality of Service (802.1p) for real-time traffic ■ VLAN (802.1Q) with double tagging and GVRP support ■ Link aggregation (802.3ad) ■ IGMP snooping for multicast filtering ■ Port rate limiting and broadcast storm limiting ■ Port configuration, status, statistics, mirroring, security ■ SNTP time synchronization (client and server) Universal Power Supply Options ■ Fully integrated power supply (no external adaptors) ■ Popular low-voltage DC ranges: 24VDC (10-36VDC) or 48VDC (36-59VDC) ■ Universal high-voltage range: 88-300VDC or 85-264VAC ■ CSA/UL 60950 safety approved to +85°C ■ Screw connection terminal blocks ensure reliable maintenance free connections Remote Dial Up Access ■ Integrated V.90 modem and PPP server ■ Provides remote access to serial devices and Ethernet LAN 4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch, 128-bit Encryption RUGGEDCOM RS401 Mounting Options Integrated V.90 Modem Failsafe Output Relay Panel or DIN Rail 56 kbps 0.4A @ 120VAC 2 A @ 30VDC Integrated Power Supply Universal high-voltage range: 88-300VDC or 85-264VAC Popular low voltage DC ranges: 24VDC (10-36VDC) 48VDC (36-59VDC) Serial Ports 4 - RS232/RS422/RS485 DB9, RJ45, or screw terminal connectors 2 kV Isolation per Port Ethernet Ports 4 -Port Ethernet Switch Fiber and Copper Ports 4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch, 128-bit Encryption RUGGEDCOM RS401 3 ROS Features Serial IP Encapsulation Many ‘legacy’ devices (RTU, PLC, IED, etc.) only support serial communications via RS232, RS422 or RS485. ROS encapsulates the serial data within a TCP connection allowing these devices to be reached via an IP network. A wide range of baud rates, frame packetization options, and diagnostics allows any serial protocol to function. The RS400 has specific support for the following serial protocols: ■ Raw socket serial encapsulation ■ Modbus TCP (client and server) ■ DNP 3 ■ WIN and TIN ■ Microlok Modbus TCP The Modbus protocol is ubiquitous in the industrial control and automation world. ROS converts Modbus RTU master/ slave serial data packets to Modbus TCP client/server packets for transmission over an IP network. This allows communications to Modbus RTU slaves via Ethernet and allows multiple masters to poll the same slave device. Cyber Security Cyber security is an urgent issue in many industries where advanced automation and communications networks play a crucial role in mission critical applications and where high reliability is of paramount importance. Key ROS features that address security issues at the local area network level include: ■ Passwords – Multi-level user passwords secures switch against unauthorized configuration ■ SSH / SSL – Extends capability of password protection to add 128-bit encryption of passwords and data as they cross the network ■ Enable/Disable ports – Capability to disable ports so that traffic can not pass ■ 802.1Q VLAN – Provides the ability to logically segregate traffic between predefined ports on switches ■ MAC based port security – The ability to secure ports on a switch so only specific Devices / MAC addresses can communicate via that port ■ 802.1x Port based network access control – The ability to lock down ports on a switch so that only authorized clients can communicate via this port ■ RADIUS – authentication service using MD5 hash and providing centralized password management ■ SNMPv3 – encrypted authentication access security and data encryption (CBC-DES with 56-bit encryption key) ■ Secure socket layer – Web-based management using SSL with data encryption (128-bit encryption key) ■ RSA – 1024 bit key for key management and key exchange ■ TACACS+ – Terminal Access Control and Accounting Services. Client provides encrypted authentication and authorization ■ Point to Point (PPP) – using CHAP (MD5 Hash) authentication service ■ SFTP – Secure File Transfer Protocol using SSH encryption 4 RUGGEDCOM RS401 The ROS cyber security features are included to help address the various industry specific security standards such as NERC CIP, ISA S99, AGA 12, IEC 62443, ISO 17799:2005 and PCSRF SPP-ICS. Enhanced Rapid Spanning Tree Protocol (eRSTP) RUGGEDCOM eRSTP allows the creation of fault-tolerant ring and mesh Ethernet networks that incorporate redundant links that are ‘pruned’ to prevent loops. eRSTP yields worst-case fault recovery 1 of 5ms times the ‘bridge diameter’ and allows rings of up to 160 switches. For example, a ring of ten switches will have fault recovery times under 50ms. eRSTP implements both STP and RSTP to ensure interoperability with commercial switches unlike other proprietary ‘ring’ solutions. Quality of Service (IEEE 802.1p) Some networking applications such as real-time control or VoIP (voice over IP) require predictable arrival times for Ethernet frames. Switches can introduce latency in times of heavy network traffic due to the internal queues that buffer frames and then transmit on a first come first serve basis. ROS supports ‘Class of Service’ in accordance with IEEE 802.1p that allows time critical traffic to jump ahead to the front of the queue thus minimizing latency and reducing jitter to allow such demanding applications to operate correctly. ROS allows priority classification by port, tags, MAC address, and IP type of service (ToS). A configurable “weighted fair queuing” algorithm controls how frames are emptied from the queues. VLAN (IEEE 802.1Q) Virtual local area networks (VLAN) allow the segregation of a physical network into separate logical networks with independent broadcast domains. A measure of security is provided since hosts can only access other hosts on the same VLAN and traffic storms are isolated. ROS supports 802.1Q tagged Ethernet frames and VLAN trunks. Port based classification allows legacy devices to be assigned to the correct VLAN. GVRP support is also provided to simplify the configuration of the switches on the VLAN. Link Aggregation (802.3ad) The link aggregation feature provides the ability to aggregate several Ethernet ports into one logical link (port trunk) with higher bandwidth. This provides an inexpensive way to set up a high speed backbone to improve network bandwidth. This feature is also known as “port trunking,” “port bundling,” “port teaming,” and “Ethernet trunk.” 1 eRSTP fault recovery times may be approximated as follows: For 100 Mbps, fault recovery performance is <5ms/hop 4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch, 128-bit Encryption ROS Features IGMP Snooping Broadcast Storm Filtering ROS uses IGMP snooping (Internet Group Management Protocol v1, v2 and v3) to intelligently forward or filter multicast traffic streams (e.g. MPEG video) to or from hosts on the network. This reduces the load on network trunks and prevents packets from being received on hosts that are not involved. ROS has a very powerful implementation of IGMP snooping that: ■ Can be enabled on a per VLAN basis ■ Detects and filters all multicast streams regardless of whether subscribers exist ■ Supports “router-less” operation by supporting an “active” mode ■ Restores traffic streams immediately after an RSTP topology change Broadcast storms wreak havoc on a network and can cause attached devices to malfunction. This could be disastrous on a network with mission critical equipment. ROS limits this by filtering broadcast frames with a user-defined threshold. SNMP (Simple Network Management Protocol) SNMP provides a standardized method for network management stations to interrogate devices from different vendors. SNMP versions supported by ROS are v1, v2c, and v3. SNMPv3, in particular, provides security features such as authentication, privacy with data encryption (CBC-DES with 56-bit encryption key) and access control not present in earlier SNMP versions. ROS also supports numerous standard MIBs (Management Information Base) allowing for easy integration with any network management system (NMS). A feature of SNMP supported by ROS is the ability to generate “traps” upon system events. RUGGEDCOM NMS, the RUGGEDCOM management solution, can record traps from multiple devices providing a powerful network troubleshooting tool. It also provides a graphical visualization of the network and is fully integrated with all RUGGEDCOM products. SCADA and Industrial Automation ROS contains features that optimize network performance and simplify switch management based on the unique requirements found in SCADA and industrial automation applications. Features such as Modbus TCP management for retrieval of switch data using the ubiquitous Modbus protocol and DHCP Option 82, a Rockwell Automation ODVA requirement for IP address assignment based on the location of the end device, provide capabilities not found in typical “commercial” or “office grade” Ethernet switches. Port Based Network Access Control (802.1x) ROS supports the IEEE 802.1x standard that defines a mechanism for port-based network access control which provides a means of authenticating and authorizing devices attached to LAN ports. Port Rate Limiting ROS supports configurable rate limiting per port to limit unicast and multicast traffic. This can be essential to managing precious network bandwidth for service providers. It also provides edge security for denial of service (DoS) attacks. Port Mirroring ROS can be configured to duplicate all traffic on one port to a designated mirror port. When combined with a network analyzer, this can be a powerful troubleshooting tool. Port Statistics and RMON (Remote Monitoring) ROS provides continuously updating statistics per port that provide both ingress and egress packet and byte counters as well as detailed error figures. Also provided is full support for the RMON statistics, history, alarms, and event groups. RMON allows for very sophisticated data collection, analysis and detection of traffic patterns. Event Logging and Alarms ROS records all significant events to a non-volatile system log allowing forensic troubleshooting. Events include link failure and recovery, unauthorized access, broadcast storm detection, and self-test diagnostics among others. Alarms provide a snapshot of recent events that have yet to be acknowledged by the network administrator. An external hardware relay is de-energized during the presence of critical alarms allowing an external controller to react if desired. HTML Web Browser and Telnet/SSH User Interfaces ROS provides a simple, intuitive user interface for configuration and monitoring via a standard graphical web browser or via Telnet/SSH. All system parameters include detailed on-line help to make setup a breeze. ROS, presents a common look and feel and standardized configuration process allowing easy migration to other RUGGEDCOM managed products. Configuration via ASCII Text File All configuration parameters are stored in an ASCII formatted text file that can easily be transferred via TFTP, SFTP or Xmodem. The configuration file can be saved for backup purposes and easily manipulated by a text editor. The same text file can be downloaded to the switch at a later date in order to re-configure or restore a previous configuration. Command Line Interface (CLI) A command line interface can be used in conjunction with remote shell to automate data retrieval, configuration updates, and firmware upgrades. A powerful SQL-like capability allows expert users the ability to selectively retrieve or manipulate any parameters the device has to offer. 4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch, 128-bit Encryption RUGGEDCOM RS401 5 EMI and Environmental Type Tests IEC 61850-3 EMI Type Tests Test Description IEC 61000-4-2 ESD IEC 61000-4-3 Radiated RFI IEC 61000-4-4 Burst (fast transient) IEC 61000-4-5 Surge IEC 61000-4-6 Induced (conducted) RFI IEC 61000-4-8 Magnetic field IEC 61000-4-29 Voltage dips and interrupts IEC 61000-4-11 IEC 61000-4-12 Damped oscillatory IEC 61000-4-16 Mains frequency voltage IEC 61000-4-17 Ripple on D.C. power supply IEC 60255-5 Dielectric strength IEC 60255-5 H.V. impulse Test Levels Severity Levels Signal ports D.C. power ports A.C. power ports Signal ports D.C. power ports D.C. power ports Signal ports D.C. power ports A.C. power ports Signal ports D.C. Power ports A.C. Power ports +/- 8kV +/- 15kV 20 V/m +/- 4kV @ 2.5kHz +/- 4kV +/- 4kV +/- 4kV +/- 4kV line-to-earth, +/- 2kV line-to-line +/- 4kV line-to-earth, +/- 1kV line-to-line +/- 4kV line-to-earth, +/- 2kV line-to-line 10V 10V 10V 10V 40 A/m continuous, 1000 A/m for 1 s 30% for 0.1s, 60% for 0.1s, 100% for 0.05s 30% for 1 period, 60% for 50 periods 100% for 5 periods, 100% for 50 periods 2 2.5kV common, 1kV diff. mode@1MHz 2.5kV common, 1kV diff. mode@1MHz 2.5kV common, 1kV diff. mode@1MHz 30V Continuous, 300V for 1s 30V Continuous, 300V for 1s 10% 2kVac (Fail-safe relay output) 1.5V DC 2kVac 5kV (Fail-safe relay output) 5kV 5kV 4 4 X X 4 4 4 4 3 4 3 3 3 3 N/A N/A N/A N/A 3 3 3 4 4 3 N/A N/A N/A N/A N/A N/A Enclosure contact Enclosure air Enclosure ports Signal ports D.C. power ports A.C. power ports Earth ground ports 3 Signal ports D.C. power ports A.C. power ports Signal ports D.C. power ports A.C. power ports Signal ports D.C. power ports A.C. power ports Test Levels +/-8kV +/-15kV 35 V/m +/- 4kV @ 2.5kHz +/- 4kV +/- 4kV +/- 4kV 2.5kV common mode@1MHz 2.5kV common, 1kV diff. mode@1MHz 2.5kV common, 1kV diff. mode@1MHz 2kVac (Fail-safe relay output) 1.5kV DC 2kVac 5kV (Fail-safe relay output) 5kV 5kV Severity Levels N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Enclosure contact Enclosure air Enclosure ports Signal ports D.C. power ports A.C. power ports Earth ground ports 3 Signal ports D.C. power ports A.C. power ports Signal ports D.C power ports A.C. power ports Earth ground ports 3 Enclosure ports D.C. power ports A.C. power ports IEEE 1613 (C37.90.x) EMI Immunity Type Tests Test Description IEEE C37.90.3 ESD IEEE C37.90.2 Radiated RFI IEEE C37.90.1 Fast transient IEEE C37.90.1 Oscillatory IEEE C37.90 Dielectric strength IEEE C37.90 H.V. impulse Environmental Type Tests Test IEC 60068-2-1 IEC 60068-2-2 IEC 60068-2-30 IEC 60255-21-1 IEC 60255-21-2 Description Cold temperature Dry heat Humidity (damp heat, cyclic) Vibration Shock Test Ad Test Bd Test Db Test Fc Test Ea Test Levels -40°C, 16 hours +85°C, 16 hours 95% (non-condensing), 55°C , 6 cycles 2g @ (10 - 150) Hz 30g @ 11mS Security Levels N/A N/A N/A Class 2 Class 2 1 RUGGEDCOM specified severity levels. 2 refers to “Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are very high, (e.g. shipboard application and for severe transportation conditions”). 3 Only applicable to functional earth connections separated from the safety earth connection. 2 Class 6 RUGGEDCOM RS401 4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch, 128-bit Encryption Technical Specifications Power Supply ■ Power consumption: 8W Max ■ 24VDC: 10-36VDC (max, 0.4A ■ 48VDC: 36-59VDC (max), 0.2A ■ HI voltage AC/DC: 88-300VDC or 85-264VAC, 0.1A Critical Alarm Relay ■ Form-C failsafe contact relay: 1A@30VDC Physical Dimensions ■ Height: 3.5” (89mm) ■ Width: 6.76” (172mm) ■ Depth: 7.42” (188mm) ■ Weight: 4.15lbs (1.9 kg) ■ Ingress protection: IP40 (1mm objects) ■ Enclosure: 18 AWG galvanized steel enclosure ■ Mounting: DIN rail or panel mounted Switch Properties ■ Switching method: Store and forward ■ Switching latency: 5 μs (100Mbps) ■ Switching bandwidth: 1.2 Gbps ■ MAC addresses: 2048 ■ MAC address table size: 16kbytes ■ Priority Queues: 4 ■ Frame buffer memory: 1-Mbit ■ Simultaneous VLANs: 255 ■ VLAN ID Range: 1 to 4094 ■ IGMP multicast groups: 256 Regulatory Approvals ■ ISO: Designed and manufactured using an ISO9001: 2000 certified quality program ■ CE marking ■ Emissions: FCC Part 15 (Class A), EN55022 (CISPR22 Class A) ■ Safety: cCSAus (Compliant with CSA C22.2 No. 60950, UL 60950, EN60950) ■ Laser eye safety (FDA/CDRH): Complies with 21 CFR Chapter 1, Subchapter J Network Management ■ HTTPS graphical web-based, SSL (128-bit encryption) ■ SNMP v1, v2c, v3 (56-bit encryption) ■ Telnet, VT100, SSH/SFTP (128-bit encryption) ■ Command Line Interface (CLI) ■ RSA Key Management (1024 bit key) ■ Authentication and Accounting – TACACS+ (encrypted), RADIUS client, PPP Warranty ■ 5 Years – Applicable to design and manufacturing related product defects EMI Immunity and Environmental Compliance ■IEC 61000-6-2 Industrial (Generic) ■IEC 61800-3 Industrial (Variable Speed Drive Systems) ■ IEC 61850-3 Electric Utility Substations ■ IEEE 1613 Electric Utility Substations ■ NEMA TS 2 Traffic Control Equipment ■Hazardous Location Class 1, Division 2 IEEE Compliance ■802.3-10BaseT ■802.3u-100BaseTX, 100BaseFX ■802.3x-Flow Control ■ 802.3D-MAC Bridges ■802.1D-Spanning Tree Protocol ■802.1p-Class of Service ■802.1Q-VLAN Tagging ■802.1w-Rapid Spanning Tree Protocol ■ 802.1x-Port Based Network Access Control ■802.1Q-2005 (formerly 802.1s) MSTP IETF RFC Compliance ■RFC768-UDP ■ RFC783-TFTP ■RFC791-IP ■RFC792-ICMP ■RFC793-TCP ■RFC826-ARP ■RFC854-Telnet ■RFC894-IP over Ethernet ■RFC1112-IGMP v1 ■RFC1519-CIDR ■RFC1541-DHCP (client) ■RFC2030-SNTP ■RFC2068-HTTP ■RFC2236-IGMP v2 ■RFC2284-EAP ■RFC2475-Differentiated Services ■RFC2865-RADIUS ■RFC3376 IGMP v3 ■RFC3414-SNMPv3-USM ■RFC3415-SNMPv3-VACM IETF SNMP MIBS ■ RFC1493-BRIDGE-MIB ■RFC1907-SNMPv2-MIB ■RFC2012-TCP-MIB ■RFC2013-UDP-MIB ■RFC2578-SNMPv2-SMI ■RFC2579-SNMPv2-TC ■ RFC2819-RMON-MIB ■RFC2863-IF-MIB ■draft-ietf-bridge-rstpmib-03-BRIDGE-MIB ■draft-ietf-bridge-bridgemib-smiv2-03-RSTP-MIB ■IANAifType-MIB 4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch, 128-bit Encryption RUGGEDCOM RS401 7 Fiber Specifications and Dimension Drawings Fiber Optical Specifications Parameter Fiber Port Type RUGGEDCOM RS401 Installation Guide Mode 10BaseFL 100BaseFX Multimode Multimode Chapter 5 Dimension Drawings Singlemode Connectors ST MTRJ, ST, SC LC, SC Typical dist. (km) 2 2 20 50 Dimension Drawings 90 Optical wavelength (nm) 820 1310 1310 1310 1310 Cable size core/cladding (um) 50/125 or 62./125 50/125 or 62./125 8/125 or 9/125 8/125 or 9/125 8/125 or 9/125 TX power (dBm) -34.4 -15.7 -15.5 -2.5 2.5 RX sensitivity (dBm) -8.2 -33.5 -32 -37 -39 Typical budget (dB) 22 17 16.5 34.5 41.5 NOTE Longer segment lengths dependent on fiber specifications. Consult factory for further details. All dimensions are in millimeters, unless otherwise stated. 8.2 151.9 127.0 174.0 188.5 10.2 8.2 22.1 88.6 172.0 Figure 20: Overall Dimensions Overall dimensions All dimensions are in millimeters, unless otherwise stated. 8 RUGGEDCOM RS401 4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch, 128-bit Encryption Chapter 5 RUGGEDCOM RS401 Dimension Drawings Installation Guide Dimension Drawings 125.7 12.7 134.4 4.1 8.1 Figure 21: Panel and Din Rail Mount Dimensions Panel and DIN rail mount dimensions All dimensions are in millimeters, unless otherwise stated. 26 4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch, 128-bit Encryption RUGGEDCOM RS401 9 Order Code 6GK6040-1AT2 - ____ - 0 - ________ - A - ______ - Z - ______ + PS1 Mount MOD E1/E2 PS: Power Supply ____ + ____ SP MP SP: Serial Port Options 1 = 24VDC (12-36VDC) 2 = 48VDC (36-59VDC) 3 = 87-264VAC or 88-300VDC B00 = 4 x RS232 via DB9 B01 = 4 x RS485 via 3 POS screw terminals B02 = 4 x RS232/RS422/RS485 via DB9 B03 = 4 x RS232/RS422/RS485 via RJ45 Mount: Mounting Options A = No mounting hardware B = Front panel mount with DIN screw points C = Side panel mount with DIN screw points MOD: Manufacturing Modifications 0 = None 1 = Conformal coating E1/E2: Addition Ethernet Ports 1 & 2 Options 1 A00 = 100FX Singlemode LC, Long Reach 90km A01 = 10FL Multimode ST, 820nm, 2km A02 = 100FX Singlemode SC, Long Reach 90km A03 = 100FX Singlemode LC, Intermediate Reach 50km A04 = 100FX Multimode MTRJ A05 = 100FX Multimode LX A06 = 100FX Multimode SC A07 = 100FX Multimode ST A08 = 100FX Multimode LC 100FX Singlemode LC, Standard 20km A09 = 100FX Singlemode LC, Standard 20km A10 = 100FX Singlemode SC, Standard 20km A11 = 100FX Singlemode SC, Intermediate Reach 50 km A12 = 10/100BaseTX RJ45 A13 = 100FX Singlemode ST, Standard 20km MP: Modem Port Options C00 = No Modem C01 = V.90 (56Kbps) Modem Notes: 1 Ports 1 & 2 must have the same type of connector ie. RJ45, MTRJ, ST, SC, LCW. All units come standard with 2 10/100Tx RJ45 Ethernet ports (on Ports 3 & 4). Example Order Codes 6GK6040-1AT21-0AA1-Z A04+B02+C00 24VDC power supply, no Mounting Hardware, Conformal Coating, 100FX Multimode MTRJ, 4 x RS232/RS422/RS485 via DB9, no modem 6GK6040-1AT23-0BA0-Z A02+B00+C01 87-264VAC or 88-300VDC, Front panel mount with DIN screw points, 100 FX Singlemode SC, Long Reach 90km, 4 x RS232 via DB9, V.90(56Kbps) Modem 10 RUGGEDCOM RS401 4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch, 128-bit Encryption Siemens Industry, Inc. 5300 Triangle Parkway Norcross, GA 30092 1-800-241-4453 [email protected] usa.siemens.com/ruggedcom Subject to change without prior notice. All rights reserved. ©2015 Siemens Industry, Inc. The information provided in this brochure contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. All product designations may be trademarks or product names of Siemens or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.