RS900GP

Product Overview
RUGGEDCOM RS900GP
10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports,
128-bit Encryption
The RUGGEDCOM RS900GP from Siemens is a utility grade,
fully managed Ethernet switch providing dual fiber optical
or copper Gigabit Ethernet ports and eight Fast Ethernet
copper ports each capable of supplying high power 802.3at
compliant Power over Ethernet. In addition, the RS900GP is
fully compatible with the RUGGEDCOM WIN CPE and Pico
Base Stations.
Designed to operate reliably in industrial environments
the RS900GP provides a high level of immunity to
electromagnetic interference and heavy electrical surges
typical of environments found in electric utility substations,
curb side traffic control cabinets, and factory floors. An
operating temperature range of -40°C to +85°C coupled
with hazardous location compliance, optional conformal
coating and a cast aluminum enclosure allows the RS900GP
to be placed in almost any location.
The embedded Rugged Operating System (ROS) provides
advanced cyber security features and comprehensive
networking functions such as Enhanced Rapid Spanning Tree
(eRSTP), Port Rate Limiting, and a full array of intelligent
functionality for high network availability and manageability.
Coupled with ruggedness and durability that is designed in
from the onset, the RS900GP is ideal for creating missioncritical, real-time, control applications where high reliability
and availability is of paramount importance.
All RUGGEDCOM products are backed by a five year warranty
and unsurpassed technical support.
The RS900GP provides two fiber optical Gigabit Ethernet
ports for creating a fiber optical backbone with high noise
immunity and long haul connectivity. The versatility and
wide selection of fiber optics allows the RS900GP to be
used in a variety of applications.
usa.siemens.com/ruggedcom
Features and Benefit
Ethernet Ports
Rugged Rated for Reliability in Harsh
Environments
■ 8 Fast Ethernet Ports (10/100BaseTX) all External
802.3af / 802.3at compliant PoE
■ Up to 2 fiber optical gigabit Ethernet ports (100/1000BaseX)
■ Up to 2 10/100/1000 BaseTx copper ports
■ Multiple fiber connector types (LC, SC, SFP
Pluggable Optics)
■ Bi-directional single strand fiber support
■ Long haul optics allow gigabit distances up to 70k
■ Immunity to EMI and heavy electrical surges
- Meets IEEE 1613 (electric utility substations)
- Exceeds IEC 61850-3 (electric utility substations)
- Exceeds IEC 61800-3 (variable speed drive systems)
- Exceeds IEC 61000-6-2 (generic industrial)
- Exceeds NEMA TS-2 (traffic control equipment)
■ -40 to +85°C operating temperature (no fans)
■ Conformal coated printed circuit boards (optional)
Power Over Ethernet (PoE)
Rugged Operating System (ROS) Features
■ 8 10/100BaseTx 802.3af / 802.3at compliant ports
■ Data and power over a single Ethernet cable
■ Auto-sensing ports that provide power only to PoE
end devices
■ Compatible with RUGGEDCOM WIN CPE and Pico
Base Stations
Cyber Security Features
■ Multi-level user passwords
■ SSH / SSL / SFTP (128-bit encryption)
■ Enable/disable ports, MAC based port security
■ Port based network access control (802.1x)
■ VLAN (802.1Q) to segregate and secure network traffic
■ RADIUS centralized password management
■ SNMPv3 authentication and 56-bit encryption
2
RUGGEDCOM RS900GP
■ Simple plug and play operation 802.3af / 802.3at
- automatic learning, negotiation, and crossover detection
■ MSTP 802.1Q-2005 (formerly 802.1s)
■ RSTP (802.1w) and Enhanced Rapid Spanning Tree
(eRSTP) network fault recovery (<5ms)
■ Quality of Service (802.1p) for real-time traffic
■ VLAN (802.1Q) with double tagging and GVRP support
■ Link aggregation (802.3ad)
■ IGMP Snooping for multicast filtering
■ Port Rate Limiting and Broadcast Storm Limiting
■ Industrial automation features (eg. Modbus)
Management Tools
■ Web-based, Telnet, CLI management interfaces
■ SNMP v1/v2/v3 (56-bit encryption)
■ Remote Monitoring (RMON)
■ Rich set of diagnostics with logging and alarms
10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption
RUGGEDCOM RS900GP
Dual Gigabit Ports
Fiber
Operating
Temperature
„ Pluggable optics (SFP)
„LC or SC connectors
„ Bi-directional (single strand)
„Distances up to 70km
„ -40°C to +85°C
„No fans
Copper
„ Copper 10/100/1000 TX
(RJ45 or Micro-D)
Rugged Construction
„Cast aluminum
enclosure
„Conformal coating
(optional)
Critical Alarm Relay
„Form-C failsafe contact relay:
1A@30VDP
Fast Ethernet ports
Dual Power Input 1
„ 8 – Fast Ethernet ports
(10/100BaseTX)
„802.3af / 802.3at
compliant
„Compatible with
RUGGEDCOM WIN CPE
and Pico Base Stations
„54VDC (44-57VDC),
160W (Powers
8 ports with 802.3af
or 4 ports 802.3at)
„2 x 54V DC, 160W
(Powers 8 ports
with 802.3at)
Mounting Options
„DIN rail
„Panel mount
1 Either
input power port can power any or all PoE ports. If both power inputs are used, the unit will share the PoE load between supplies.
The aggregate power required from the supplies to fully power the eight 802.3at PoE ports is 240W.
10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption
RUGGEDCOM RS900GP
3
ROS Features
Cyber Security
Cyber security is an urgent issue in many industries where
advanced automation and communications networks play
a crucial role in mission critical applications and where high
reliability is of paramount importance. Key ROS features that
address security issues at the local area network
level include:
■ Passwords – Multi-level user passwords secures switch
against unauthorized configuration
■ SSH / SSL – Extends capability of password protection
to add encryption of passwords and data as they cross
the network
■ Enable/Disable ports – Capability to disable ports so
that traffic can not pass
■ 802.1Q VLAN – Provides the ability to logically segregate
traffic between predefined ports on switches
■ MAC based port security – The ability to secure ports
on a switch so only specific Devices / MAC addresses
can communicate via that port
■ 802.1x Port based network access control – The ability
to lock down ports on a switch so that only authorized
clients can communicate via this port
■ RADIUS – authentication service using MD5 hash and
providing centralized password management
■ SNMPv3 – encrypted authentication access security and data encryption (CBC-DES with 56-bit encryption key)
■ Secure Socket Layer – Web-based management using
SSL with data encryption (128-bit encryption key)
■ RSA – 1024 bit key for key management and key exchange
■ TACACS+ – Terminal Access Control and Accounting
Services. Client provides encrypted authentication
and authorization.
■ Point to Point (PPP) – using CHAP (MD5 Hash)
authentication service
■ SFTP – Secure File Transfer Protocol using SSH encryption
The ROS cyber security features are included to help address
the various industry specific security standards such as
NERC CIP, ISA S99, AGA 12, IEC 62443, ISO 17799:2005
and PCSRF SPP-ICS.
Enhanced Rapid Spanning Tree Protocol
(eRSTP)
RUGGEDCOM eRSTP allows the creation of fault-tolerant
ring and mesh Ethernet networks that incorporate
redundant links that are ‘pruned’ to prevent loops. eRSTP
yields worst-case fault recovery1 of 5ms times the ‘bridge
diameter’ and allows rings of up to 160 switches. For
example, a ring of ten switches will have fault recovery
times under 50ms. eRSTP implements both STP and
RSTP to ensure interoperability with commercial switches
unlike other proprietary ‘ring’ solutions.
Quality of Service (IEEE 802.1p)
Some networking applications such as real-time control
or VoIP (voice over IP) require predictable arrival times for
Ethernet frames. Switches can introduce latency in times
of heavy network traffic due to the internal queues that
buffer frames and then transmit on a first come first serve
basis. ROS supports ‘Class of Service’ in accordance with
IEEE 802.1p that allows time critical traffic to jump ahead
to the front of the queue thus minimizing latency and
reducing jitter to allow such demanding applications to
operate correctly. ROS allows priority classification by
port, tags, MAC address, and IP type of service (ToS). A
configurable “weighted fair queing” algorithm controls
how frames are emptied from the queues.
VLAN (IEEE 802.1Q)
Virtual local area networks (VLAN) allow the segregation
of a physical network into separate logical networks with
independent broadcast domains. A measure of security is
provided since hosts can only access other hosts on the
same VLAN and traffic storms are isolated. ROS supports
802.1Q tagged Ethernet frames and VLAN trunks. Port
based classification allows legacy devices to be assigned
to the correct VLAN. GVRP support is also provided to
simplify the configuration of the switches on the VLAN.
Link Aggregation (802.3ad)
The link aggregation feature provides the ability to
aggregate several Ethernet ports into one logical link (port
trunk) with higher bandwidth. This provides an inexpensive
way to set up a high speed backbone to improve network
bandwidth. This feature is also known as “port trunking,”
“port bundling,” “port teaming,” and “Ethernet trunk.”
IGMP Snooping
ROS uses IGMP snooping (Internet Group Management
Protocol v1&v2) to intelligently forward or filter multicast
traffic streams (e.g. MPEG video) to or from hosts on the
network. This reduces the load on network trunks and
prevents packets from being received on hosts that are
not involved. ROS has a very powerful implementation
of IGMP snooping that:
■ Can be enabled on a per VLAN basis
■ Detects and filters all multicast streams regardless of whether subscribers exist
■ Supports “router-less” operation by supporting an
“active” mode
■ Restores traffic streams immediately after an RSTP
topology change
1 eRSTP fault recovery times may be approximated as follows:
For 100 Mbps, fault recovery performance is <5ms/hop
For 1,000 Mbps, fault recovery performance is <5ms/hop + 20ms
4
RUGGEDCOM RS900GP
10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption
ROS Features
SNMP (Simple Network Management Protocol)
Loss of Link Management
SNMP provides a standardized method for network
management stations to interrogate devices from different
vendors. SNMP versions supported by ROS are v1, v2c, and
v3. SNMPv3, in particular, provides security features such as
authentication, privacy with data encryption (CBC-DES with
56-bit encryption key) and access control not present in
earlier SNMP versions. ROS also supports numerous standard
MIBs (Management Information Base) allowing for easy
integration with any network management system (NMS).
Some intelligent electronic devices (IEDs) have dual fiber
optic ports with automatic failover to a backup port should
the primary fail. ROS ensures this mechanism works reliably
under all failure modes by appropriately disabling link signals
when required. ROS also flushes learned MAC addresses to
ensure the failover occurs quickly.
A feature of SNMP supported by ROS is the ability to
generate “traps” upon system events. RUGGEDCOM NMS, the
RUGGEDCOM management solution, can record traps from
multiple devices providing a powerful network troubleshooting
tool. It also provides a graphical visualization of the network
and is fully integrated with all RUGGEDCOM products.
Port Configuration and Status
ROS allows individual ports to be ‘hard’ configured for speed,
duplex, auto-negotiation, flow control and more. This allows
proper connection with devices that do not negotiate or have
unusual settings. Detailed status of ports with alarm and SNMP
trap on link problems aid greatly in system troubleshooting.
Port Statistics and RMON (Remote Monitoring)
SNTP automatically synchronizes the internal clock of all
ROS devices on the network. This allows for correlation
of time stamped events for troubleshooting.
ROS provides continuously updating statistics per port that
provide both ingress and egress packet and byte counters as
well as detailed error figures. Also provided is full support
for the RMON statistics, history, alarms, and event groups.
RMON allows for very sophisticated data collection, analysis
and detection of traffic patterns.
SCADA and Industrial Automation
Event Logging and Alarms
ROS contains features that optimize network performance
and simplify switch management based on the unique
requirements found in SCADA and industrial automation
applications. Features such as Modbus TCP management
for retrieval of switch data using the ubiquitous Modbus
protocol and DHCP Option 82, a Rockwell Automation ODVA
requirement for IP address assignment based on the location
of the end device, provide capabilities not found in typical
“commercial” or “office grade” Ethernet switches.
ROS records all significant events to a non-volatile system
log allowing forensic troubleshooting. Events include link
failure and recovery, unauthorized access, broadcast storm
detection, and self-test diagnostics among others. Alarms
provide a snapshot of recent events that have yet to be
acknowledged by the network administrator. An external
hardware relay is de-energized during the presence of
critical alarms allowing an external controller to react
if desired.
Port Based Network Access Control (802.1x)
HTML Web Browser and Telnet/SSH User
Interfaces
SNTP (Simple Network Time Protocol)
ROS supports the IEEE 802.1x standard that defines a
mechanism for port-based network access control which
provides a means of authenticating and authorizing
devices attached to LAN ports.
Port Rate Limiting
ROS supports configurable rate limiting per port to limit
unicast and multicast traffic. This can be essential to managing
precious network bandwidth for service providers. It also
provides edge security for denial of service (DoS) attacks.
Broadcast Storm Filtering
Broadcast storms wreak havoc on a network and can cause
attached devices to malfunction. This could be disastrous on
a network with mission critical equipment. ROS limits this by
filtering broadcast frames with a user-defined threshold.
Port Mirroring
ROS can be configured to duplicate all traffic on one port to
a designated mirror port. When combined with a network
analyzer, this can be a powerful troubleshooting tool.
ROS provides a simple, intuitive user interface for configuration
and monitoring via a standard graphical web browser or via
Telnet/SSH. All system parameters include detailed on-line
help to make setup a breeze. ROS, presents a common look
and feel and standardized configuration process allowing
easy migration to other RUGGEDCOM managed products.
Configuration Via ASCII Text File
All configuration parameters are stored in an ASCII formatted
text file that can easily be transferred via TFTP, SFTP or
Xmodem. The configuration file can be saved for backup
purposes and easily manipulated by a text editor. The same
text file can be downloaded to the switch at a later date in
order tore-configure or restore a previous configuration.
Command Line Interface (CLI)
A command line interface can be used in conjunction with
remote shell to automate data retrieval, configuration updates,
and firmware upgrades. A powerful SQL-like capability allows
expert users the ability to selectively retrieve or manipulate any
parameters the device has to offer.
10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption
RUGGEDCOM RS900GP
5
EMI and Environmental Type Tests
IEC 61850-3 EMI Type Tests
Test
Description
IEC 61000-4-2
ESD
IEC 61000-4-3
Radiated RFI
IEC 61000-4-4
Burst (fast transient)
IEC 61000-4-5
Surge
IEC 61000-4-6
Induced (conducted) RFI
Test Levels
Severity Levels
Enclosure contact
Enclosure air
Enclosure ports
Signal ports
D.C. power ports
Earth ground ports 3
+/- 8kV
+/- 15kV
20 V/m
+/- 2kV @ 2.5kHz
+/- 2kV
+/- 2kV
4
4
x
x
4
4
Signal ports
+/- 2kV line-to-earth, +/- 1.5kV line-to-line
4
D.C. power ports
Signal ports
D.C power ports
Earth ground ports 3
3
3
3
3
N/A
N/A
N/A
3
3
4
4
3
N/A
N/A
N/A
N/A
IEC 61000-4-8
Magnetic field
Enclosure ports
IEC 61000-4-29
Voltage dips and interrupts
IEC 61000-4-12
Damped oscillatory
IEC 61000-4-16
Mains frequency voltage
IEC 61000-4-17
Ripple on D.C. power supply
IEC 60255-5
Dielectric strength
IEC 60255-5
H.V. impulse
D.C. power ports
Signal ports
D.C. power ports
Signal ports
D.C. power ports
D.C. power ports
Signal ports
D.C. power ports
Signal ports
D.C. Power ports
+/- 1.5V line-to-earth, +/- 1kV line-to-line
10V
10V
10V
40 A/m continuous, 1000 A/m for 1 s
1000 A/m for 1 s
30% for 0.1s, 60% for 0.1s, 100% for 0.05s
2.5kV common, 1kV diff. mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
30V Continuous, 300V for 1s
30V Continuous, 300V for 1s
10%
1.5k V AC (Fail-safe relay output)
1.5V DC
5kV (Fail-safe relay output)
5kV
Enclosure contact
Enclosure air
Enclosure ports
Test Levels
+/- 8kV
+/-12kV
35 V/m
Severity Levels
N/A
N/A
N/A
Signal ports
D.C. power ports
Earth ground ports 3
Signal ports
D.C. power ports
Signal ports
D.C. power ports
+/- 2kV @ 2.5kHz
+/-2kV
+/- 2kV
2.5kV common mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
5kV (Fail-safe relay output)
5kV
N/A
N/A
N/A
N/A
N/A
N/A
N/A
IEEE 1613 (C37.90.x) EMI Immunity Type Tests
Test
Description
IEEE C37.90.3
ESD
IEEE C37.90.2
Radiated RFI
IEEE C37.90.1
Fast transient
IEEE C37.90.1
Oscillatory
IEEE C37.90
H.V. impulse
Environmental Type Tests
Test
Description
Test Levels
Severity Levels
IEC 60068-2-1
Cold temperature
Test Ad
-40°C, 16 hours
N/A
IEC 60068-2-2
Dry heat
Test Bd
+85°C, 16 hours
N/A
IEC 60068-2-30
Humidity (damp heat, cyclic) Test Db
95% (non-condensing), 55°C , 6 cycles
N/A
IEC 60255-21-1
Vibration
Test Fc
2g @ (10 - 150) Hz
Class 2 2
IEC 60255-21-2
Shock
Test Ea
30g @ 11mS
Class 2 2
1 RUGGEDCOM
specified severity levels.
2 refers to “Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are
very high, (e.g. shipboard application and for severe transportation conditions”).
3 Only applicable to functional earth connections separated from the safety earth connection.
2 Class
6
RUGGEDCOM RS900GP
10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption
Technical Specifications
Power Supply
■ 54VDC, 160W (Powers 8 ports with 802.3af or
4 ports 802.3at)
■ 2 x 54VDC, 160W (Powers 8 ports with 802.3at
Notes:
- One power supply will power RS900GP and 8 ports with 802.3af,
or 4 ports with 802.3at
- Two power supplies will power RS900GP and 8 ports with 802.3af with load sharing redundancy or 8 ports with 802.3at
Critical Alarm Relay
■ Form-C failsafe contact relay:
1A@30VDC
Physical Dimensions
■ Height: 6.95” (177mm)
■ Width: 3.63” (92mm)
■ Depth: 6.08” (154mm)
■ Weight: 2.5kg
■ Ingress Protection: IP40 (1mm objects)
■ Enclosure: Cast aluminum
■ Mounting: DIN rail or panel mounted
Switch Properties
■ Switching method: Store and forward
■ Switching latency: 7 us
■ Switching bandwidth: 5.6 Gbps
■ MAC addresses: 8192
■ MAC address table size: 32kbytes
■ Priority queues: 4
■ Frame buffer memory: 2 Mbit
■ VLANs: 255
■ IGMP multicast groups: 256
■ Port rate limiting: 128kbps, 256, 512, 4, 8Mbps
■ No head of line blocking
Regulatory Approvals
■ ISO: Designed and manufactured using a ISO9001:
2000 certified quality program
■ CE marking
■ Emissions: FCC Part 15 (Class A), EN55022 (CISPR22 Class A)
■ Safety: cCSAus (Compliant with CSA C22.2 No. 60950,
UL 60950, EN60950)
■ Laser eye safety (FDA/CDRH): Complies with 21 CFR
Chapter 1, Subchapter J
Network Management
■ HTTPS graphical web-based, SSL (128-bit encryption)
■ SNMP v1, v2c, v3 (56-bit encryption)
■ Telnet, VT100, SSH/SFTP (128-bit encryption)
■ Command Line Interface (CLI)
■ RSA key management (1024 bit key)
■ Authentication and accounting - TACACS+ (encrypted),
RADIUS client, PPP
Warranty
■ 5 Years – Applicable to design and manufacturing related
product defects.
EMI Immunity and Environmental Compliance
■IEC 61000-6-2 Industrial (Generic)
■IEC 61800-3 Industrial (Variable Speed Drive Systems)
■ IEC 61850-3 Electric Utility Substations
■ IEEE 1613 Electric Utility Substations
■ NEMA TS 2 Traffic Control Equipment
■ EN 50121-4 Railway Applications
■ Hazardous Locations: Class 1, Division 2
IEEE Compliance
■ 802.3-10BaseT
■ 802.3af / 802.3at
■802.3u-100BaseTX, 100BaseFX
■802.3x-Flow Control
■802.3z-1000BaseLX
■802.3ab-1000BaseTX
■802.3ad-Link Aggregation
■802.1d-MAC Bridges
■802.1d-Spanning Tree Protocol
■802.1p-Class of Service
■802.1Q-VLAN Tagging
■802.1w-Rapid Spanning Tree Protocol
■802.1x-Port Based Network Access Control
■802.1Q-2005 (formerly 802.1s) MSTP
IETF RFC Compliance
■RFC768-UDP
■ RFC783-TFTP
■ RFC791-IP
■RFC792-ICMP
■RFC793-TCP
■ RFC826-ARP
■ RFC854-Telnet
■RFC894-IP over Ethernet
■RFC1112-IGMP v1
■ RFC1519-CIDR
■ RFC1541-DHCP (client)
■ RFC2030-SNTP
■RFC2068-HTTP
■RFC2236-IGMP v2
■ RFC2284-EAP
■RFC2475-Differentiated Services
■RFC2865-RADIUS
■RFC3414-SNMPv3-USM
■RFC3415-SNMPv3-VACM
IETF SNMP MIBS
■ RFC1493-BRIDGE-MIB
■RFC1907-SNMPv2-MIB
■RFC2012-TCP-MIB
■RFC2013-UDP-MIB
■RFC2578-SNMPv2-SMI
■RFC2579-SNMPv2-TC
■RFC2819-RMON-MIB
■RFC2863-IF-MIB
■draft-ietf-bridge-rstpmib-03-BRIDGE-MIB
■draft-ietf-bridge-bridgemib-smiv2-03-RSTP-MIB
■IANAifType-MIB
10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption
RUGGEDCOM RS900GP
7
Fiber Specifications and Dimension Drawings
Fiber
Optical
RUGGEDCOM
RS900GP
Specifications
Chapter 5
Installation
Guide
Parameter
Dimension Drawings
Fiber Port Type
Mode
Multimode
Singlemode
Singlemode
Singlemode
Connector
LC, LC-SFP
SC, LC, LC-SFP
SC, LC, LC-SFP
LC-SFP
Dimension Drawings
Typical Dist.
500m
10km
25km
70km
Optical Wavelength (nm)
850
1310
1310
1550
Cable Size Core/Cladding (um)
50 / 125 or 62.5 / 125
8 / 125 or 9 / 125
8 / 125 or 9 / 125
8 / 125 or 9 / 125
TX Power (Min/Max) (dBm)
-9.5 / -4
-9 /-3
-7 / -3
0/5
RX Sensitivity (dBm)
-20
-22
-26
-23
0
-3
NOTE
RX Saturation
(dBm)
All dimensions are in millimeters,
unless otherwise
stated.
14
17
Typical Budget (dB)
0
25
154.4
176.5
89.9
-3
19
Figure 14: Overall Dimensions
Overall dimensions
All dimensions are in millimeters, unless otherwise stated.
8
RUGGEDCOM RS900GP
10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption
Chapter 5
RUGGEDCOM RS900GP
Dimension Drawings
Installation Guide
Dimension Drawings
174.2
163.1
175.8
Figure
DIN Rail
Mount Dimensions
DIN rail15:
mount
dimensions
All dimensions are in millimeters, unless otherwise stated.
22
10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption
RUGGEDCOM RS900GP
9
Order Codes
6GK60900PS2 - 0 - 0 - _______ - A - ________ - Z _______
PS1 PS2 Mount
MOD
P9P10
PS1: Power Supply 1
0 = External power supply required. Available as accessory. MLFB: 6GK6000-8HS00-0AA0
PS1: Power Supply 2
0 = External power supply required. Available as accessory. MLFB: 6GK6000-8HS00-0AA0
Mount: Mounting options
A = No mounting option
B = DIN rail mounting
C = Panel mounting
MOD: Manufacturing Modifications
0 = None
1 = Conformal coating
P9P10: Port 9 and Port 10 Transceiver Options
A00 = None
A01 = 2 x 10/100/1000Tx RJ45
A02 = 2 x 1000SX - Multimode, 850nm, LC, 500m
A03 = 2 x 1000LX - Singlemode, 1310nm, SC connectors, 10km
A04 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 10km
A05 = 2 x 1000LX - Singlemode, 1310nm, SC connectors, 25km
A06 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 25km
A07 = 2 x 100FX - Multimode, 1300nm, SC
A08 = 2 x 100FX - Singlemode, 1310nm, SC, 20km
A09 = 2 x 100FX - Singlemode, 1310nm, SC, 50km
A10 = 2 x 100FX - Singlemode, 1310nm, SC, 90km
A11 = 2 x 1000LX SFP - Blank (no optical transceiver)
A12 = 2 x 1000SX SFP - Multimode, 850nm, LC, 500m 1, 3
A13 = 2 x 1000LX SFP - Singlemode, 1310nm, LC, 10km 1, 3
A14 = 2 x 1000LX SFP - Singlemode, 1310nm, LC, 25km 1, 3
A15 = 2 x 1000LX SFP - Singlemode, 1550nm, LC, 70km 1, 2, 3
A16 = 2 x 1000TX SFP - RJ45
A17 = 2 x 10/100/1000TX micro-D
Power Supply Requirements
54VDC, 160W (Powers 8 ports with 802.3af
or 4 ports 802.3at)
2 x 54VDC, 160W (Powers 8 ports with 802.3at)
1 Distance
ratings are typical but will depend on type of cabling, number of connectors and splices.
you not find an appropriate fiber optic option listed here, please consult Siemens for other options.
3 These tranceivers have an operating temperature range of -20 to +85°C.
All other transceivers have an operating temperature range of -40° to +85°C.
2 Should
10
RUGGEDCOM RS900GP
10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption
Example Order Codes
6GK6090-0PS20-0BA0-Z A12
Din Rail Mount, Dual 1000SX Multimode LC 850nm 500m
6GK6090-0PS20-0CA1-Z A14
Panel Mount, Dual 1000LX Singlemode LC 1310nm 25km,
Conformal Coating
6GK6090-0PS20-0AA1-Z A03
Dual 1000LX Singlemode SC 1310nm 10km,
Conformal Coating
10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption
RUGGEDCOM RS900GP
11
Siemens Industry, Inc.
5300 Triangle Parkway
Norcross, GA 30092
1-800-241-4453
[email protected]
usa.siemens.com/ruggedcom
Subject to change without prior notice.
All rights reserved.
©2015 Siemens Industry, Inc.
The information provided in this brochure contains descriptions or
characteristics of performance which in case of actual use do not
always apply as described or which may change as a result of
further development of the products. An obligation to provide
the respective characteristics shall only exist if expressly agreed in
the terms of contract. Availability and technical specifications are
subject to change without notice.
All product designations may be trademarks or product names
of Siemens AG or supplier companies whose use by third parties
for their own purposes could violate the rights of the owners.