Product Overview RUGGEDCOM RS900GP 10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption The RUGGEDCOM RS900GP from Siemens is a utility grade, fully managed Ethernet switch providing dual fiber optical or copper Gigabit Ethernet ports and eight Fast Ethernet copper ports each capable of supplying high power 802.3at compliant Power over Ethernet. In addition, the RS900GP is fully compatible with the RUGGEDCOM WIN CPE and Pico Base Stations. Designed to operate reliably in industrial environments the RS900GP provides a high level of immunity to electromagnetic interference and heavy electrical surges typical of environments found in electric utility substations, curb side traffic control cabinets, and factory floors. An operating temperature range of -40°C to +85°C coupled with hazardous location compliance, optional conformal coating and a cast aluminum enclosure allows the RS900GP to be placed in almost any location. The embedded Rugged Operating System (ROS) provides advanced cyber security features and comprehensive networking functions such as Enhanced Rapid Spanning Tree (eRSTP), Port Rate Limiting, and a full array of intelligent functionality for high network availability and manageability. Coupled with ruggedness and durability that is designed in from the onset, the RS900GP is ideal for creating missioncritical, real-time, control applications where high reliability and availability is of paramount importance. All RUGGEDCOM products are backed by a five year warranty and unsurpassed technical support. The RS900GP provides two fiber optical Gigabit Ethernet ports for creating a fiber optical backbone with high noise immunity and long haul connectivity. The versatility and wide selection of fiber optics allows the RS900GP to be used in a variety of applications. usa.siemens.com/ruggedcom Features and Benefit Ethernet Ports Rugged Rated for Reliability in Harsh Environments ■ 8 Fast Ethernet Ports (10/100BaseTX) all External 802.3af / 802.3at compliant PoE ■ Up to 2 fiber optical gigabit Ethernet ports (100/1000BaseX) ■ Up to 2 10/100/1000 BaseTx copper ports ■ Multiple fiber connector types (LC, SC, SFP Pluggable Optics) ■ Bi-directional single strand fiber support ■ Long haul optics allow gigabit distances up to 70k ■ Immunity to EMI and heavy electrical surges - Meets IEEE 1613 (electric utility substations) - Exceeds IEC 61850-3 (electric utility substations) - Exceeds IEC 61800-3 (variable speed drive systems) - Exceeds IEC 61000-6-2 (generic industrial) - Exceeds NEMA TS-2 (traffic control equipment) ■ -40 to +85°C operating temperature (no fans) ■ Conformal coated printed circuit boards (optional) Power Over Ethernet (PoE) Rugged Operating System (ROS) Features ■ 8 10/100BaseTx 802.3af / 802.3at compliant ports ■ Data and power over a single Ethernet cable ■ Auto-sensing ports that provide power only to PoE end devices ■ Compatible with RUGGEDCOM WIN CPE and Pico Base Stations Cyber Security Features ■ Multi-level user passwords ■ SSH / SSL / SFTP (128-bit encryption) ■ Enable/disable ports, MAC based port security ■ Port based network access control (802.1x) ■ VLAN (802.1Q) to segregate and secure network traffic ■ RADIUS centralized password management ■ SNMPv3 authentication and 56-bit encryption 2 RUGGEDCOM RS900GP ■ Simple plug and play operation 802.3af / 802.3at - automatic learning, negotiation, and crossover detection ■ MSTP 802.1Q-2005 (formerly 802.1s) ■ RSTP (802.1w) and Enhanced Rapid Spanning Tree (eRSTP) network fault recovery (<5ms) ■ Quality of Service (802.1p) for real-time traffic ■ VLAN (802.1Q) with double tagging and GVRP support ■ Link aggregation (802.3ad) ■ IGMP Snooping for multicast filtering ■ Port Rate Limiting and Broadcast Storm Limiting ■ Industrial automation features (eg. Modbus) Management Tools ■ Web-based, Telnet, CLI management interfaces ■ SNMP v1/v2/v3 (56-bit encryption) ■ Remote Monitoring (RMON) ■ Rich set of diagnostics with logging and alarms 10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption RUGGEDCOM RS900GP Dual Gigabit Ports Fiber Operating Temperature Pluggable optics (SFP) LC or SC connectors Bi-directional (single strand) Distances up to 70km -40°C to +85°C No fans Copper Copper 10/100/1000 TX (RJ45 or Micro-D) Rugged Construction Cast aluminum enclosure Conformal coating (optional) Critical Alarm Relay Form-C failsafe contact relay: 1A@30VDP Fast Ethernet ports Dual Power Input 1 8 – Fast Ethernet ports (10/100BaseTX) 802.3af / 802.3at compliant Compatible with RUGGEDCOM WIN CPE and Pico Base Stations 54VDC (44-57VDC), 160W (Powers 8 ports with 802.3af or 4 ports 802.3at) 2 x 54V DC, 160W (Powers 8 ports with 802.3at) Mounting Options DIN rail Panel mount 1 Either input power port can power any or all PoE ports. If both power inputs are used, the unit will share the PoE load between supplies. The aggregate power required from the supplies to fully power the eight 802.3at PoE ports is 240W. 10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption RUGGEDCOM RS900GP 3 ROS Features Cyber Security Cyber security is an urgent issue in many industries where advanced automation and communications networks play a crucial role in mission critical applications and where high reliability is of paramount importance. Key ROS features that address security issues at the local area network level include: ■ Passwords – Multi-level user passwords secures switch against unauthorized configuration ■ SSH / SSL – Extends capability of password protection to add encryption of passwords and data as they cross the network ■ Enable/Disable ports – Capability to disable ports so that traffic can not pass ■ 802.1Q VLAN – Provides the ability to logically segregate traffic between predefined ports on switches ■ MAC based port security – The ability to secure ports on a switch so only specific Devices / MAC addresses can communicate via that port ■ 802.1x Port based network access control – The ability to lock down ports on a switch so that only authorized clients can communicate via this port ■ RADIUS – authentication service using MD5 hash and providing centralized password management ■ SNMPv3 – encrypted authentication access security and data encryption (CBC-DES with 56-bit encryption key) ■ Secure Socket Layer – Web-based management using SSL with data encryption (128-bit encryption key) ■ RSA – 1024 bit key for key management and key exchange ■ TACACS+ – Terminal Access Control and Accounting Services. Client provides encrypted authentication and authorization. ■ Point to Point (PPP) – using CHAP (MD5 Hash) authentication service ■ SFTP – Secure File Transfer Protocol using SSH encryption The ROS cyber security features are included to help address the various industry specific security standards such as NERC CIP, ISA S99, AGA 12, IEC 62443, ISO 17799:2005 and PCSRF SPP-ICS. Enhanced Rapid Spanning Tree Protocol (eRSTP) RUGGEDCOM eRSTP allows the creation of fault-tolerant ring and mesh Ethernet networks that incorporate redundant links that are ‘pruned’ to prevent loops. eRSTP yields worst-case fault recovery1 of 5ms times the ‘bridge diameter’ and allows rings of up to 160 switches. For example, a ring of ten switches will have fault recovery times under 50ms. eRSTP implements both STP and RSTP to ensure interoperability with commercial switches unlike other proprietary ‘ring’ solutions. Quality of Service (IEEE 802.1p) Some networking applications such as real-time control or VoIP (voice over IP) require predictable arrival times for Ethernet frames. Switches can introduce latency in times of heavy network traffic due to the internal queues that buffer frames and then transmit on a first come first serve basis. ROS supports ‘Class of Service’ in accordance with IEEE 802.1p that allows time critical traffic to jump ahead to the front of the queue thus minimizing latency and reducing jitter to allow such demanding applications to operate correctly. ROS allows priority classification by port, tags, MAC address, and IP type of service (ToS). A configurable “weighted fair queing” algorithm controls how frames are emptied from the queues. VLAN (IEEE 802.1Q) Virtual local area networks (VLAN) allow the segregation of a physical network into separate logical networks with independent broadcast domains. A measure of security is provided since hosts can only access other hosts on the same VLAN and traffic storms are isolated. ROS supports 802.1Q tagged Ethernet frames and VLAN trunks. Port based classification allows legacy devices to be assigned to the correct VLAN. GVRP support is also provided to simplify the configuration of the switches on the VLAN. Link Aggregation (802.3ad) The link aggregation feature provides the ability to aggregate several Ethernet ports into one logical link (port trunk) with higher bandwidth. This provides an inexpensive way to set up a high speed backbone to improve network bandwidth. This feature is also known as “port trunking,” “port bundling,” “port teaming,” and “Ethernet trunk.” IGMP Snooping ROS uses IGMP snooping (Internet Group Management Protocol v1&v2) to intelligently forward or filter multicast traffic streams (e.g. MPEG video) to or from hosts on the network. This reduces the load on network trunks and prevents packets from being received on hosts that are not involved. ROS has a very powerful implementation of IGMP snooping that: ■ Can be enabled on a per VLAN basis ■ Detects and filters all multicast streams regardless of whether subscribers exist ■ Supports “router-less” operation by supporting an “active” mode ■ Restores traffic streams immediately after an RSTP topology change 1 eRSTP fault recovery times may be approximated as follows: For 100 Mbps, fault recovery performance is <5ms/hop For 1,000 Mbps, fault recovery performance is <5ms/hop + 20ms 4 RUGGEDCOM RS900GP 10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption ROS Features SNMP (Simple Network Management Protocol) Loss of Link Management SNMP provides a standardized method for network management stations to interrogate devices from different vendors. SNMP versions supported by ROS are v1, v2c, and v3. SNMPv3, in particular, provides security features such as authentication, privacy with data encryption (CBC-DES with 56-bit encryption key) and access control not present in earlier SNMP versions. ROS also supports numerous standard MIBs (Management Information Base) allowing for easy integration with any network management system (NMS). Some intelligent electronic devices (IEDs) have dual fiber optic ports with automatic failover to a backup port should the primary fail. ROS ensures this mechanism works reliably under all failure modes by appropriately disabling link signals when required. ROS also flushes learned MAC addresses to ensure the failover occurs quickly. A feature of SNMP supported by ROS is the ability to generate “traps” upon system events. RUGGEDCOM NMS, the RUGGEDCOM management solution, can record traps from multiple devices providing a powerful network troubleshooting tool. It also provides a graphical visualization of the network and is fully integrated with all RUGGEDCOM products. Port Configuration and Status ROS allows individual ports to be ‘hard’ configured for speed, duplex, auto-negotiation, flow control and more. This allows proper connection with devices that do not negotiate or have unusual settings. Detailed status of ports with alarm and SNMP trap on link problems aid greatly in system troubleshooting. Port Statistics and RMON (Remote Monitoring) SNTP automatically synchronizes the internal clock of all ROS devices on the network. This allows for correlation of time stamped events for troubleshooting. ROS provides continuously updating statistics per port that provide both ingress and egress packet and byte counters as well as detailed error figures. Also provided is full support for the RMON statistics, history, alarms, and event groups. RMON allows for very sophisticated data collection, analysis and detection of traffic patterns. SCADA and Industrial Automation Event Logging and Alarms ROS contains features that optimize network performance and simplify switch management based on the unique requirements found in SCADA and industrial automation applications. Features such as Modbus TCP management for retrieval of switch data using the ubiquitous Modbus protocol and DHCP Option 82, a Rockwell Automation ODVA requirement for IP address assignment based on the location of the end device, provide capabilities not found in typical “commercial” or “office grade” Ethernet switches. ROS records all significant events to a non-volatile system log allowing forensic troubleshooting. Events include link failure and recovery, unauthorized access, broadcast storm detection, and self-test diagnostics among others. Alarms provide a snapshot of recent events that have yet to be acknowledged by the network administrator. An external hardware relay is de-energized during the presence of critical alarms allowing an external controller to react if desired. Port Based Network Access Control (802.1x) HTML Web Browser and Telnet/SSH User Interfaces SNTP (Simple Network Time Protocol) ROS supports the IEEE 802.1x standard that defines a mechanism for port-based network access control which provides a means of authenticating and authorizing devices attached to LAN ports. Port Rate Limiting ROS supports configurable rate limiting per port to limit unicast and multicast traffic. This can be essential to managing precious network bandwidth for service providers. It also provides edge security for denial of service (DoS) attacks. Broadcast Storm Filtering Broadcast storms wreak havoc on a network and can cause attached devices to malfunction. This could be disastrous on a network with mission critical equipment. ROS limits this by filtering broadcast frames with a user-defined threshold. Port Mirroring ROS can be configured to duplicate all traffic on one port to a designated mirror port. When combined with a network analyzer, this can be a powerful troubleshooting tool. ROS provides a simple, intuitive user interface for configuration and monitoring via a standard graphical web browser or via Telnet/SSH. All system parameters include detailed on-line help to make setup a breeze. ROS, presents a common look and feel and standardized configuration process allowing easy migration to other RUGGEDCOM managed products. Configuration Via ASCII Text File All configuration parameters are stored in an ASCII formatted text file that can easily be transferred via TFTP, SFTP or Xmodem. The configuration file can be saved for backup purposes and easily manipulated by a text editor. The same text file can be downloaded to the switch at a later date in order tore-configure or restore a previous configuration. Command Line Interface (CLI) A command line interface can be used in conjunction with remote shell to automate data retrieval, configuration updates, and firmware upgrades. A powerful SQL-like capability allows expert users the ability to selectively retrieve or manipulate any parameters the device has to offer. 10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption RUGGEDCOM RS900GP 5 EMI and Environmental Type Tests IEC 61850-3 EMI Type Tests Test Description IEC 61000-4-2 ESD IEC 61000-4-3 Radiated RFI IEC 61000-4-4 Burst (fast transient) IEC 61000-4-5 Surge IEC 61000-4-6 Induced (conducted) RFI Test Levels Severity Levels Enclosure contact Enclosure air Enclosure ports Signal ports D.C. power ports Earth ground ports 3 +/- 8kV +/- 15kV 20 V/m +/- 2kV @ 2.5kHz +/- 2kV +/- 2kV 4 4 x x 4 4 Signal ports +/- 2kV line-to-earth, +/- 1.5kV line-to-line 4 D.C. power ports Signal ports D.C power ports Earth ground ports 3 3 3 3 3 N/A N/A N/A 3 3 4 4 3 N/A N/A N/A N/A IEC 61000-4-8 Magnetic field Enclosure ports IEC 61000-4-29 Voltage dips and interrupts IEC 61000-4-12 Damped oscillatory IEC 61000-4-16 Mains frequency voltage IEC 61000-4-17 Ripple on D.C. power supply IEC 60255-5 Dielectric strength IEC 60255-5 H.V. impulse D.C. power ports Signal ports D.C. power ports Signal ports D.C. power ports D.C. power ports Signal ports D.C. power ports Signal ports D.C. Power ports +/- 1.5V line-to-earth, +/- 1kV line-to-line 10V 10V 10V 40 A/m continuous, 1000 A/m for 1 s 1000 A/m for 1 s 30% for 0.1s, 60% for 0.1s, 100% for 0.05s 2.5kV common, 1kV diff. mode@1MHz 2.5kV common, 1kV diff. mode@1MHz 30V Continuous, 300V for 1s 30V Continuous, 300V for 1s 10% 1.5k V AC (Fail-safe relay output) 1.5V DC 5kV (Fail-safe relay output) 5kV Enclosure contact Enclosure air Enclosure ports Test Levels +/- 8kV +/-12kV 35 V/m Severity Levels N/A N/A N/A Signal ports D.C. power ports Earth ground ports 3 Signal ports D.C. power ports Signal ports D.C. power ports +/- 2kV @ 2.5kHz +/-2kV +/- 2kV 2.5kV common mode@1MHz 2.5kV common, 1kV diff. mode@1MHz 5kV (Fail-safe relay output) 5kV N/A N/A N/A N/A N/A N/A N/A IEEE 1613 (C37.90.x) EMI Immunity Type Tests Test Description IEEE C37.90.3 ESD IEEE C37.90.2 Radiated RFI IEEE C37.90.1 Fast transient IEEE C37.90.1 Oscillatory IEEE C37.90 H.V. impulse Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068-2-1 Cold temperature Test Ad -40°C, 16 hours N/A IEC 60068-2-2 Dry heat Test Bd +85°C, 16 hours N/A IEC 60068-2-30 Humidity (damp heat, cyclic) Test Db 95% (non-condensing), 55°C , 6 cycles N/A IEC 60255-21-1 Vibration Test Fc 2g @ (10 - 150) Hz Class 2 2 IEC 60255-21-2 Shock Test Ea 30g @ 11mS Class 2 2 1 RUGGEDCOM specified severity levels. 2 refers to “Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are very high, (e.g. shipboard application and for severe transportation conditions”). 3 Only applicable to functional earth connections separated from the safety earth connection. 2 Class 6 RUGGEDCOM RS900GP 10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption Technical Specifications Power Supply ■ 54VDC, 160W (Powers 8 ports with 802.3af or 4 ports 802.3at) ■ 2 x 54VDC, 160W (Powers 8 ports with 802.3at Notes: - One power supply will power RS900GP and 8 ports with 802.3af, or 4 ports with 802.3at - Two power supplies will power RS900GP and 8 ports with 802.3af with load sharing redundancy or 8 ports with 802.3at Critical Alarm Relay ■ Form-C failsafe contact relay: 1A@30VDC Physical Dimensions ■ Height: 6.95” (177mm) ■ Width: 3.63” (92mm) ■ Depth: 6.08” (154mm) ■ Weight: 2.5kg ■ Ingress Protection: IP40 (1mm objects) ■ Enclosure: Cast aluminum ■ Mounting: DIN rail or panel mounted Switch Properties ■ Switching method: Store and forward ■ Switching latency: 7 us ■ Switching bandwidth: 5.6 Gbps ■ MAC addresses: 8192 ■ MAC address table size: 32kbytes ■ Priority queues: 4 ■ Frame buffer memory: 2 Mbit ■ VLANs: 255 ■ IGMP multicast groups: 256 ■ Port rate limiting: 128kbps, 256, 512, 4, 8Mbps ■ No head of line blocking Regulatory Approvals ■ ISO: Designed and manufactured using a ISO9001: 2000 certified quality program ■ CE marking ■ Emissions: FCC Part 15 (Class A), EN55022 (CISPR22 Class A) ■ Safety: cCSAus (Compliant with CSA C22.2 No. 60950, UL 60950, EN60950) ■ Laser eye safety (FDA/CDRH): Complies with 21 CFR Chapter 1, Subchapter J Network Management ■ HTTPS graphical web-based, SSL (128-bit encryption) ■ SNMP v1, v2c, v3 (56-bit encryption) ■ Telnet, VT100, SSH/SFTP (128-bit encryption) ■ Command Line Interface (CLI) ■ RSA key management (1024 bit key) ■ Authentication and accounting - TACACS+ (encrypted), RADIUS client, PPP Warranty ■ 5 Years – Applicable to design and manufacturing related product defects. EMI Immunity and Environmental Compliance ■IEC 61000-6-2 Industrial (Generic) ■IEC 61800-3 Industrial (Variable Speed Drive Systems) ■ IEC 61850-3 Electric Utility Substations ■ IEEE 1613 Electric Utility Substations ■ NEMA TS 2 Traffic Control Equipment ■ EN 50121-4 Railway Applications ■ Hazardous Locations: Class 1, Division 2 IEEE Compliance ■ 802.3-10BaseT ■ 802.3af / 802.3at ■802.3u-100BaseTX, 100BaseFX ■802.3x-Flow Control ■802.3z-1000BaseLX ■802.3ab-1000BaseTX ■802.3ad-Link Aggregation ■802.1d-MAC Bridges ■802.1d-Spanning Tree Protocol ■802.1p-Class of Service ■802.1Q-VLAN Tagging ■802.1w-Rapid Spanning Tree Protocol ■802.1x-Port Based Network Access Control ■802.1Q-2005 (formerly 802.1s) MSTP IETF RFC Compliance ■RFC768-UDP ■ RFC783-TFTP ■ RFC791-IP ■RFC792-ICMP ■RFC793-TCP ■ RFC826-ARP ■ RFC854-Telnet ■RFC894-IP over Ethernet ■RFC1112-IGMP v1 ■ RFC1519-CIDR ■ RFC1541-DHCP (client) ■ RFC2030-SNTP ■RFC2068-HTTP ■RFC2236-IGMP v2 ■ RFC2284-EAP ■RFC2475-Differentiated Services ■RFC2865-RADIUS ■RFC3414-SNMPv3-USM ■RFC3415-SNMPv3-VACM IETF SNMP MIBS ■ RFC1493-BRIDGE-MIB ■RFC1907-SNMPv2-MIB ■RFC2012-TCP-MIB ■RFC2013-UDP-MIB ■RFC2578-SNMPv2-SMI ■RFC2579-SNMPv2-TC ■RFC2819-RMON-MIB ■RFC2863-IF-MIB ■draft-ietf-bridge-rstpmib-03-BRIDGE-MIB ■draft-ietf-bridge-bridgemib-smiv2-03-RSTP-MIB ■IANAifType-MIB 10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption RUGGEDCOM RS900GP 7 Fiber Specifications and Dimension Drawings Fiber Optical RUGGEDCOM RS900GP Specifications Chapter 5 Installation Guide Parameter Dimension Drawings Fiber Port Type Mode Multimode Singlemode Singlemode Singlemode Connector LC, LC-SFP SC, LC, LC-SFP SC, LC, LC-SFP LC-SFP Dimension Drawings Typical Dist. 500m 10km 25km 70km Optical Wavelength (nm) 850 1310 1310 1550 Cable Size Core/Cladding (um) 50 / 125 or 62.5 / 125 8 / 125 or 9 / 125 8 / 125 or 9 / 125 8 / 125 or 9 / 125 TX Power (Min/Max) (dBm) -9.5 / -4 -9 /-3 -7 / -3 0/5 RX Sensitivity (dBm) -20 -22 -26 -23 0 -3 NOTE RX Saturation (dBm) All dimensions are in millimeters, unless otherwise stated. 14 17 Typical Budget (dB) 0 25 154.4 176.5 89.9 -3 19 Figure 14: Overall Dimensions Overall dimensions All dimensions are in millimeters, unless otherwise stated. 8 RUGGEDCOM RS900GP 10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption Chapter 5 RUGGEDCOM RS900GP Dimension Drawings Installation Guide Dimension Drawings 174.2 163.1 175.8 Figure DIN Rail Mount Dimensions DIN rail15: mount dimensions All dimensions are in millimeters, unless otherwise stated. 22 10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption RUGGEDCOM RS900GP 9 Order Codes 6GK60900PS2 - 0 - 0 - _______ - A - ________ - Z _______ PS1 PS2 Mount MOD P9P10 PS1: Power Supply 1 0 = External power supply required. Available as accessory. MLFB: 6GK6000-8HS00-0AA0 PS1: Power Supply 2 0 = External power supply required. Available as accessory. MLFB: 6GK6000-8HS00-0AA0 Mount: Mounting options A = No mounting option B = DIN rail mounting C = Panel mounting MOD: Manufacturing Modifications 0 = None 1 = Conformal coating P9P10: Port 9 and Port 10 Transceiver Options A00 = None A01 = 2 x 10/100/1000Tx RJ45 A02 = 2 x 1000SX - Multimode, 850nm, LC, 500m A03 = 2 x 1000LX - Singlemode, 1310nm, SC connectors, 10km A04 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 10km A05 = 2 x 1000LX - Singlemode, 1310nm, SC connectors, 25km A06 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 25km A07 = 2 x 100FX - Multimode, 1300nm, SC A08 = 2 x 100FX - Singlemode, 1310nm, SC, 20km A09 = 2 x 100FX - Singlemode, 1310nm, SC, 50km A10 = 2 x 100FX - Singlemode, 1310nm, SC, 90km A11 = 2 x 1000LX SFP - Blank (no optical transceiver) A12 = 2 x 1000SX SFP - Multimode, 850nm, LC, 500m 1, 3 A13 = 2 x 1000LX SFP - Singlemode, 1310nm, LC, 10km 1, 3 A14 = 2 x 1000LX SFP - Singlemode, 1310nm, LC, 25km 1, 3 A15 = 2 x 1000LX SFP - Singlemode, 1550nm, LC, 70km 1, 2, 3 A16 = 2 x 1000TX SFP - RJ45 A17 = 2 x 10/100/1000TX micro-D Power Supply Requirements 54VDC, 160W (Powers 8 ports with 802.3af or 4 ports 802.3at) 2 x 54VDC, 160W (Powers 8 ports with 802.3at) 1 Distance ratings are typical but will depend on type of cabling, number of connectors and splices. you not find an appropriate fiber optic option listed here, please consult Siemens for other options. 3 These tranceivers have an operating temperature range of -20 to +85°C. All other transceivers have an operating temperature range of -40° to +85°C. 2 Should 10 RUGGEDCOM RS900GP 10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption Example Order Codes 6GK6090-0PS20-0BA0-Z A12 Din Rail Mount, Dual 1000SX Multimode LC 850nm 500m 6GK6090-0PS20-0CA1-Z A14 Panel Mount, Dual 1000LX Singlemode LC 1310nm 25km, Conformal Coating 6GK6090-0PS20-0AA1-Z A03 Dual 1000LX Singlemode SC 1310nm 10km, Conformal Coating 10-port PoE Managed Ethernet Switch With Gigabit Uplink Ports, 128-bit Encryption RUGGEDCOM RS900GP 11 Siemens Industry, Inc. 5300 Triangle Parkway Norcross, GA 30092 1-800-241-4453 [email protected] usa.siemens.com/ruggedcom Subject to change without prior notice. All rights reserved. ©2015 Siemens Industry, Inc. The information provided in this brochure contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.