Product Overview RUGGEDCOM RS416P Modular Serial Device Server with Integrated Power Over Ethernet (PoE), 128-bit Encryption The RUGGEDCOM RS416P from Siemens is a utility grade serial device server with an integrated, fully managed 4-port Power over Ethernet (PoE) switch. Featuring a modular design that can support up to 16 serial ports, the RS416P is able to interconnect multiple types of intelligent electronic devices (IEDs) that have different methods of communications. The high port density of the RS416 results in fewer overall serial servers, which reduces overall system costs, extends the useful life of existing legacy IEDs, and minimizes capital expenditures for new equipment. Designed to operate reliably in electrically harsh and climatically demanding environments, the RS416P provides a high level of immunity to electromagnetic interference and heavy electrical surges typical of environments found in electric utility substations, curb side traffic control cabinets, and factory floors. An operating temperature range of -40°C to +85°C coupled with hazardous location compliance (Class 1 Division 2), optional conformal coating and a galvanized steel enclosure, allows the RS416P to be placed in almost any location. Options include 24VDC, 48VDC, 88-300VDC, and 85-264VAC, allowing for great installation flexibility. The embedded Rugged Operating System (ROS) provides advanced cyber security features and comprehensive networking functions such as Enhanced Rapid Spanning Tree (eRSTP), Port Rate Limiting, and a full array of intelligent functionality for high network availability and manageability. Coupled with ruggedness and durability that is designed in from the onset, the RS416P is ideal for creating mission critical, real-time, control applications where high reliability and availability is of paramount importance. All RUGGEDCOM products are backed by a five year warranty and unsurpassed technical support. The RS416P also includes a wide range of power supply options for multiple industries and worldwide operability. usa.siemens.com/ruggedcom Features and Benefits Serial Device Server ■ Modular design allows for 4, 8, 12 or 16 serial ports ■ Software selectable EIA RS422 / TIA RS485, RS422, RS232 serial ports – DB9 or RJ45 connectors ■ Transmit serial data over an IP network ■ Support for Modbus TCP, DNP3, WIN, TIN, and Microlock serial protocols ■ Baud rates up to 230 kbps ■ Raw socket mode allows conversion of any serial protocol ■ Point-to-point and multi-point modes ■ Converts Modbus RTU to Modbus ■ Converts Modbus RTU to Modbus; Multiple Modbus masters ■ Converts DNP3.0 to DNP over UDP/TCP ■ 2 or 4 10/100BaseTx 802.3af compliant ports ■ Data and power over a single Ethernet cable ■ Powered from the internal 48VDC source ■ No mid-span patch panel required ■ Fully compatible with 802.3af powered devices ■ Auto-sensing ports that provide power only to PoE end devices ■ Power to port is turned off if cables are removed ■ Optional 2 Port Fast Ethernet Module ■ Multi-level user passwords ■ SSH/SSL (128-bit encryption) ■ Enable/disable ports, MAC based port security ■ Port based network access control (802.1x) ■ VLAN (802.1Q) to segregate and secure network traffic ■ RADIUS centralized password management ■ SNMPv3 authentication and 56-bit encryption Management Tools ■ Immunity to EMI and heavy electrical surges - Meets IEEE 1613 (electric utility substations) - Exceeds IEC 61850-3 (electric utility substations) - Exceeds IEEE 61800-3 (variable speed drive systems) - Exceeds IEC 61000-6-2 (generic industrial) - Exceeds NEMA TS-2 (traffic control equipment) ■ Fully independent 2kV (RMS) isolated serial ports ■ -40°C to +85°C operating temperature (no fans) ■ 18 AWG galvanized steel enclosure ■ Hazardous Location Compliance: Class 1 Division 2 Universal Power Supply Options Power Over Ethernet (PoE) Cyber Security Features Rugged Rated for Reliability in Harsh Environments ■ Fully integrated power supplies ■ PoE power supply: 48VDC ■ Unit power supply: 24VDC (10-36VDC), 48VDC (36-59VDC), or 88-300VDC/85-264VAC ■ Screw or pluggable terminal blocks ensure reliable maintenance free connections ■ CSA/UL 60950 safety approved to +85°C Rugged Operating System (ROS) Features ■ Simple plug and play operation – automatic learning, negotiation, and crossover detection ■ RSTP (802.1w) and Enhanced Rapid Spanning Tree (eRSTP) network fault recovery (<5ms) ■ Quality of Service (802.1p) for real-time traffic ■ VLAN (802.1Q) with double tagging and GVRP support ■ IGMP Snooping for multicast filtering ■ Port Rate Limiting and Broadcast Storm Limiting ■ Port configuration, status, statistics, mirroring, security ■ SNTP time synchronization (client and server) ■ Web-based, Telnet, CLI management interfaces ■ SNMP v1/v2/v3 (56-bit encryption) ■ Remote Monitoring (RMON) ■ Rich set of diagnostics with logging and alarms 2 RUGGEDCOM RS416P Modular Serial Device Server with Integrated Power Over Ethernet (PoE), 128-bit Encryption RUGGEDCOM RS416P Integrated Power Supply Universal high-voltage range: 88-300VDC or 85-264VAC Popular low voltage DC ranges: 24VDC (12-36VDC), 48VDC (36-59VDC) Separate 48VDC PoE Power Supply Screw or pluggable terminal blocks available Operating Temperature Critical Alarm Relay -40°C to +85°C No fans Form-C contact ratings: Max voltage 250VAC,125VDC Max current 2A@250VAC, 2A@30VDC Mounting Options Serial Port Types Fast Ethernet Port Types Panel/Din rail 19” rack mount Up to 16 Serial Ports Software Selectable RS232/RS422/RS485 DB9 or RJ45 connectors Fiber Serial Interface Mix and match types and connector Optional 2 Fast Ethernet Ports 10/100TX RJ45 10FL Multimode 100FX Multimode Modularity Power Over Ethernet Modular HMI 4 available slots 4, 8, 12, 16 Serial Port Configurations 2 or 4 10/100BaseTx Ports 802.3af Compliant Ports Auto-sensing Front or rear mount Modular Serial Device Server with Integrated Power Over Ethernet (PoE), 128-bit Encryption RUGGEDCOM RS416P 3 ROS Features Serial IP Encapsulation Many ‘legacy’ devices (RTU, PLC, IED, etc.) only support serial communications via RS232, RS422 or RS485. ROS encapsulates the serial data within a TCP connection allowing these devices to be reached via an IP network. A wide range of baud rates, frame packetization options, and diagnostics allows any serial protocol to function. The RS400 has specific support for the following serial protocols: ■ Raw socket serial encapsulation ■ Modbus TCP (client and server) ■ DNP 3 ■ WIN and TIN ■ Microlok Modbus TCP The Modbus protocol is ubiquitous in the industrial control and automation world. ROS converts Modbus RTU master/ slave serial data packets to Modbus TCP client/server packets for transmission over an IP network. This allows communications to Modbus RTU slaves via Ethernet and allows multiple masters to poll the same slave device. Cyber Security Cyber security is an urgent issue in many industries where advanced automation and communications networks play a crucial role in mission critical applications and where high reliability is of paramount importance. Key ROS features that address security issues at the local area network level include: ■ Passwords – Multi-level user passwords secures switch against unauthorized configuration ■ SSH / SSL – Extends capability of password protection to add 128-bit encryption of passwords and data as they cross the network ■ Enable/Disable ports – Capability to disable ports so that traffic can not pass ■ 802.1Q VLAN – Provides the ability to logically segregate traffic between predefined ports on switches ■ MAC based port security – The ability to secure ports on a switch so only specific Devices / MAC addresses can communicate via that port ■ 802.1x Port based network access control – The ability to lock down ports on a switch so that only authorized clients can communicate via this port ■ RADIUS – authentication service using MD5 hash and providing centralized password management ■ SNMPv3 – encrypted authentication access security and data encryption (CBC-DES with 56-bit encryption key) ■ Secure socket layer – Web-based management using SSL with data encryption (128-bit encryption key) ■ RSA – 1024 bit key for key management and key exchange ■ TACACS+ – Terminal Access Control and Accounting Services. Client provides encrypted authentication and authorization ■ Point to Point (PPP) – using CHAP (MD5 Hash) authentication service ■ SFTP – Secure File Transfer Protocol using SSH encryption 4 RUGGEDCOM RS416P The ROS cyber security features are included to help address the various industry specific security standards such as NERC CIP, ISA S99, AGA 12, IEC 62443, ISO 17799:2005 and PCSRF SPP-ICS. Enhanced Rapid Spanning Tree Protocol (eRSTP) RUGGEDCOM eRSTP allows the creation of fault-tolerant ring and mesh Ethernet networks that incorporate redundant links that are ‘pruned’ to prevent loops. eRSTP yields worst-case fault recovery 1 of 5ms times the ‘bridge diameter’ and allows rings of up to 160 switches. For example, a ring of ten switches will have fault recovery times under 50ms. eRSTP implements both STP and RSTP to ensure interoperability with commercial switches unlike other proprietary ‘ring’ solutions. Quality of Service (IEEE 802.1p) Some networking applications such as real-time control or VoIP (voice over IP) require predictable arrival times for Ethernet frames. Switches can introduce latency in times of heavy network traffic due to the internal queues that buffer frames and then transmit on a first come first serve basis. ROS supports ‘Class of Service’ in accordance with IEEE 802.1p that allows time critical traffic to jump ahead to the front of the queue thus minimizing latency and reducing jitter to allow such demanding applications to operate correctly. ROS allows priority classification by port, tags, MAC address, and IP type of service (ToS). A configurable “weighted fair queuing” algorithm controls how frames are emptied from the queues. VLAN (IEEE 802.1Q) Virtual local area networks (VLAN) allow the segregation of a physical network into separate logical networks with independent broadcast domains. A measure of security is provided since hosts can only access other hosts on the same VLAN and traffic storms are isolated. ROS supports 802.1Q tagged Ethernet frames and VLAN trunks. Port based classification allows legacy devices to be assigned to the correct VLAN. GVRP support is also provided to simplify the configuration of the switches on the VLAN. Link Aggregation (802.3ad) The link aggregation feature provides the ability to aggregate several Ethernet ports into one logical link (port trunk) with higher bandwidth. This provides an inexpensive way to set up a high speed backbone to improve network bandwidth. This feature is also known as “port trunking,” “port bundling,” “port teaming,” and “Ethernet trunk.” 1 eRSTP fault recovery times may be approximated as follows: For 100 Mbps, fault recovery performance is <5ms/hop Modular Serial Device Server with Integrated Power Over Ethernet (PoE), 128-bit Encryption ROS Features IGMP Snooping Broadcast Storm Filtering ROS uses IGMP snooping (Internet Group Management Protocol v1, v2 and v3) to intelligently forward or filter multicast traffic streams (e.g. MPEG video) to or from hosts on the network. This reduces the load on network trunks and prevents packets from being received on hosts that are not involved. ROS has a very powerful implementation of IGMP snooping that: ■ Can be enabled on a per VLAN basis ■ Detects and filters all multicast streams regardless of whether subscribers exist ■ Supports “router-less” operation by supporting an “active” mode ■ Restores traffic streams immediately after an RSTP topology change Broadcast storms wreak havoc on a network and can cause attached devices to malfunction. This could be disastrous on a network with mission critical equipment. ROS limits this by filtering broadcast frames with a user-defined threshold. SNMP (Simple Network Management Protocol) SNMP provides a standardized method for network management stations to interrogate devices from different vendors. SNMP versions supported by ROS are v1, v2c, and v3. SNMPv3, in particular, provides security features such as authentication, privacy with data encryption (CBC-DES with 56-bit encryption key) and access control not present in earlier SNMP versions. ROS also supports numerous standard MIBs (Management Information Base) allowing for easy integration with any network management system (NMS). A feature of SNMP supported by ROS is the ability to generate “traps” upon system events. RUGGEDCOM NMS, the RUGGEDCOM management solution, can record traps from multiple devices providing a powerful network troubleshooting tool. It also provides a graphical visualization of the network and is fully integrated with all RUGGEDCOM products. SCADA and Industrial Automation ROS contains features that optimize network performance and simplify switch management based on the unique requirements found in SCADA and industrial automation applications. Features such as Modbus TCP management for retrieval of switch data using the ubiquitous Modbus protocol and DHCP Option 82, a Rockwell Automation ODVA requirement for IP address assignment based on the location of the end device, provide capabilities not found in typical “commercial” or “office grade” Ethernet switches. Port Based Network Access Control (802.1x) ROS supports the IEEE 802.1x standard that defines a mechanism for port-based network access control which provides a means of authenticating and authorizing devices attached to LAN ports. Port Rate Limiting ROS supports configurable rate limiting per port to limit unicast and multicast traffic. This can be essential to managing precious network bandwidth for service providers. It also provides edge security for denial of service (DoS) attacks. Port Mirroring ROS can be configured to duplicate all traffic on one port to a designated mirror port. When combined with a network analyzer, this can be a powerful troubleshooting tool. Port Statistics and RMON (Remote Monitoring) ROS provides continuously updating statistics per port that provide both ingress and egress packet and byte counters as well as detailed error figures. Also provided is full support for the RMON statistics, history, alarms, and event groups. RMON allows for very sophisticated data collection, analysis and detection of traffic patterns. Event Logging and Alarms ROS records all significant events to a non-volatile system log allowing forensic troubleshooting. Events include link failure and recovery, unauthorized access, broadcast storm detection, and self-test diagnostics among others. Alarms provide a snapshot of recent events that have yet to be acknowledged by the network administrator. An external hardware relay is de-energized during the presence of critical alarms allowing an external controller to react if desired. HTML Web Browser and Telnet/SSH User Interfaces ROS provides a simple, intuitive user interface for configuration and monitoring via a standard graphical web browser or via Telnet/SSH. All system parameters include detailed on-line help to make setup a breeze. ROS, presents a common look and feel and standardized configuration process allowing easy migration to other RUGGEDCOM managed products. Configuration via ASCII Text File All configuration parameters are stored in an ASCII formatted text file that can easily be transferred via TFTP, SFTP or Xmodem. The configuration file can be saved for backup purposes and easily manipulated by a text editor. The same text file can be downloaded to the switch at a later date in order to re-configure or restore a previous configuration. Command Line Interface (CLI) A command line interface can be used in conjunction with remote shell to automate data retrieval, configuration updates, and firmware upgrades. A powerful SQL-like capability allows expert users the ability to selectively retrieve or manipulate any parameters the device has to offer. Modular Serial Device Server with Integrated Power Over Ethernet (PoE), 128-bit Encryption RUGGEDCOM RS416P 5 EMI and Environmental Type Tests IEC 61850-3 EMI Type Tests Test Description IEC 61000-4-2 ESD IEC 61000-4-3 Radiated RFI IEC 61000-4-4 Burst (fast transient) IEC 61000-4-5 Surge IEC 61000-4-6 Induced (conducted) RFI IEC 61000-4-8 Magnetic field IEC 61000-4-29 Test Levels Severity Levels Enclosure contact Enclosure air Enclosure ports Signal ports D.C. power ports A.C. power ports Earth ground ports 3 +/- 8kV +/- 15kV 20 V/m +/- 4kV @ 2.5kHz +/- 4kV +/- 4kV +/- 4kV 4 4 Note 1 Note 1 4 4 4 Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line 4 D.C. power ports A.C. power ports Signal ports D.C power ports A.C. power ports Earth ground ports 3 Signal ports D.C. power ports A.C. power ports Signal ports D.C. power ports D.C. power ports Signal ports D.C. power ports A.C. power ports Signal ports D.C. Power ports A.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line +/- 4kV line-to-earth, +/- 2kV line-to-line 10V 10V 10V 10V 40 A/m continuous, 1000 A/m for 1 s 1000 A/m for 1 s 30% for 0.1s, 60% for 0.1s, 100% for 0.05s 30% for 1 period, 60% for 50 periods 100% for 5 periods, 100% for 50 periods 2.5kV common, 1kV diff. mode@1MHz 2.5kV common, 1kV diff. mode@1MHz 2.5kV common, 1kV diff. mode@1MHz 30V Continuous, 300V for 1s 30V Continuous, 300V for 1s 10% 2kVac (Fail-safe relay output) 1.5V DC 2kVac 5kV (Fail-safe relay output) 5kV 5kV 3 4 3 3 3 3 Note 1 5 N/A N/A N/A 3 3 3 4 4 3 N/A N/A N/A N/A N/A N/A Enclosure contact Enclosure air Enclosure ports Test Levels +/-2kV, +/-4kV, +/-8kV +/-4kV, +/-8kV, +/-15kV 35 V/m Severity Levels N/A N/A N/A Signal ports D.C. power ports A.C. power ports Earth ground ports 3 Signal ports D.C. power ports A.C. power ports Signal ports D.C. power ports A.C. power ports Signal ports D.C. power ports A.C. power ports +/- 4kV @ 2.5kHz +/- 4kV +/- 4kV +/- 4kV 2.5kV common mode@1MHz 2.5kV common, 1kV diff. mode@1MHz 2.5kV common, 1kV diff. mode@1MHz 5kV (Fail-safe relay output) 5kV 5kV 2kVac 1.5kVac 2kVac N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Enclosure ports D.C. power ports Voltage dips and interrupts IEC 61000-4-11 IEC 61000-4-12 Damped oscillatory IEC 61000-4-16 Mains frequency voltage IEC 61000-4-17 Ripple on D.C. power supply IEC 60255-5 Dielectric strength IEC 60255-5 H.V. impulse A.C. power ports IEEE 1613 (C37.90.x) EMI Immunity Type Tests Test Description IEEE C37.90.3 ESD IEEE C37.90.2 Radiated RFI IEEE C37.90.1 Fast transient IEEE C37.90.1 Oscillatory IEEE C37.90 H.V. impulse IEEE C37.90 Dielectric strength Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068-2-1 Cold temperature Test Ad -40°C, 16 hours N/A IEC 60068-2-2 Dry heat Test Bd +85°C, 16 hours N/A IEC 60068-2-30 Humidity (damp heat, cyclic) Test Db 95% (non-condensing), 55°C, 6 cycles N/A IEC 60255-21-1 Vibration Test Fc 2g @ (10 - 150) Hz Class 2 2 IEC 60255-21-2 Shock Test Ea 30g @ 11mS Class 2 2 1 RUGGEDCOM specified severity levels. 2 Class 2 refers to “Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are very high, (e.g. shipboard application and for severe transportation conditions”). 3 Only applicable to functional earth connections separated from the safety earth connection. 6 RUGGEDCOM RS416P Modular Serial Device Server with Integrated Power Over Ethernet (PoE), 128-bit Encryption Technical Specifications Power Supply ■ Power consumption: 15W Max ■ 24VDC: 10-36VDC Max ■ 48VDC: 36-59VDC Max ■ HI voltage AC/DC: 88-300VDC or 85-264VAC Max ■ PoE Power Supply: 48VDC: 36-59VDC, 0.6A Physical Dimensions ■ Height: 1.74” (44mm) ■ Width: 18.3” (464mm) ■ Depth: 12.4” (315mm) ■ Weight: 5.2kg ■ Ingress protection: IP40 (1mm objects) ■ Enclosure: 18 AWG galvanized steel enclosure ■ Mounting: DIN rail or panel mounted Switch Properties ■ Switching method: Store and forward ■ Switching latency: 7 μs ■ Switching bandwidth: 800 Mbps ■ MAC addresses: 4096 ■ MAC address table size: 32kbytes ■ Priority queues: 4 ■ Frame buffer memory: 2 Mbit ■ Simultaneous VLANs: 255 ■ VLANs: 4096 ■ VLAN ID range: 1 to 4096 ■ IGMP multicast groups: 256 ■ Port rate limiting: 128kbps, 256, 512, 4, 8Mbps ■ No head of line blocking Regulatory Approvals ■ ISO: Designed and manufactured using an ISO9001: 2000 certified quality program ■ CE marking ■ Emissions: FCC Part 15 (Class A), EN55022 (CISPR22 Class A) ■ Safety: cCSAus (Compliant with CSA C22.2 No. 60950, UL 60950, EN60950) ■ Laser eye safety (FDA/CDRH): Complies with 21 CFR Chapter 1, Subchapter J Network Management ■ HTTP graphical web-based, SSL (128-bit encryption) ■ SNMP v1, v2c, v3 (56-bit encryption) ■ Telnet, VT100, SSH/SFTP (128-bit encryption) ■ Command Line Interface (CLI) ■ RSA key management (1024 bit key) ■ Authentication and accounting - TACACS+ (encrypted), RADIUS client, PPP Warranty ■ 5 Years – Applicable to design and manufacturing related product defects EMI Immunity and Environmental Compliance ■IEC 61000-6-2 Industrial (Generic) ■IEC 61800-3 Industrial (Variable Speed Drive Systems) ■ IEC 61850-3 Electric Utility Substations ■ IEEE 1613 Electric Utility Substations ■ NEMA TS 2 Traffic Control Equipment ■Hazardous Locations: Class 1 Division 2 IEEE Compliance ■ 802.3-10BaseT ■802.3u-100BaseTX, 100BaseFX ■802.3x-Flow Control ■ 802.3z-1000BaseLX ■ 802.3ab-1000BaseTX ■ 802.3ad-Link Aggregation ■ 802.1D-MAC Bridges ■ 802.1D-Spanning Tree Protocol ■ 802.1p-Class of Service ■ 802.1Q-VLAN Tagging ■ 802.1w-Rapid Spanning Tree Protocol ■ 802.1x-Port Based Network Access Control IETF RFC Compliance ■RFC768-UDP ■ RFC783-TFTP ■ RFC791-IP ■RFC792-ICMP ■RFC793-TCP ■ RFC826-ARP ■ RFC854-Telnet ■RFC894-IP over Ethernet ■RFC1112-IGMP v1 ■ RFC1519-CIDR ■ RFC1541-DHCP (client) ■ RFC2030-SNTP ■RFC2068-HTTP ■RFC2236-IGMP v2 ■ RFC2284-EAP ■RFC2475-Differentiated Services ■RFC2865-RADIUS ■RFC3376 IGMP v3 ■RFC3414-SNMPv3-USM ■RFC3415-SNMPv3-VACM IETF SNMP MIBS ■ RFC1493-BRIDGE-MIB ■RFC1907-SNMPv2-MIB ■RFC2012-TCP-MIB ■RFC2013-UDP-MIB ■RFC2578-SNMPv2-SMI ■RFC2579-SNMPv2-TC ■RFC2819-RMON-MIB ■RFC2863-IF-MIB ■draft-ietf-bridge-rstpmib-03-BRIDGE-MIB ■draft-ietf-bridge-bridgemib-smiv2-03-RSTP-MIB ■IANAifType-MIB Modular Serial Device Server with Integrated Power Over Ethernet (PoE), 128-bit Encryption RUGGEDCOM RS416P 7 Fiber Specifications and Dimension Drawings Fiber Optical Specifications RUGGEDCOM RS416P Parameter Installation Guide Chapter 5 Fiber Port Type Dimension Drawings 10BaseFL 100BaseFX Mode Multimode Multimode Singlemode Connectors ST MTRJ, ST, SC, LC LC, SC, ST Typical dist. (km) 2 2 20 50 90 Optical wavelength (nm) 820 1310 1310 1310 1310 Cable size core/cladding (um) 50/125 or 62./125 50/125 or 62./125 8/125 or 9/125 TX power (dBm) -34.4 -15.7 -15.5 -2.5 2.5 RX sensitivity (dBm) -8.2 -33.5 -32 -37 -39 Typical budget (dB) 22 17 16.5 34.5 41.5 Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. Longer segment lengths dependent on fiber specifications. Consult factory for further details. 303.28 44.45 285.24 438.15 Figure dimensions 31: Overall Dimensions Overall All dimensions are in millimeters, unless otherwise stated. 8 RUGGEDCOM RS416P Modular Serial Device Server with Integrated Power Over Ethernet (PoE), 128-bit Encryption Dimension Drawings Chapter 5 RUGGEDCOM RS416P 25.40 28.96 6.35 479.30 461.01 31.75 6.35 12.70 308.10 50.80 Installation Guide 314.71 Dimension Drawings 11.68 21.08 32.64 4.57 Figure 32: Rack Mount Dimensions Rack mount dimensions All dimensions are in millimeters, unless otherwise stated. 34 Modular Serial Device Server with Integrated Power Over Ethernet (PoE), 128-bit Encryption RUGGEDCOM RS416P 9 Dimension Drawings RUGGEDCOM RS416P Chapter 5 Dimension Drawings 486.4 476.3 51.6 38.9 Installation Guide 84.1 134.3 285.5 159.8 158.0 125.5 127.5 80.0 7.4 10.4 11.7 Figure 33: Panel and DIN Rail Mount Dimensions Panel and DIN rail mount dimensions All dimensions are in millimeters, unless otherwise stated. 10 RUGGEDCOM RS416P Modular Serial Device Server with Integrated Power Over Ethernet (PoE), 128-bit Encryption 35 Order Code 6GK6041-6PT2 - ____ - ____ - _______ - _____ - _____ - Z A ___ + B ___ + C ___ + D ___ + E ___ + ___ P1 P2 Mount Main MOD S1 S2 S3 S4 S5 S6 Slot 1 Slot 3 Slot 5 Slot 2 Slot 4 Slot 6 RS416P P1: Unit Power Supply 1 = 24VDC (12-36VDC) 2 = 48VDC (36-59VDC) 3 = 85-264VAC or 88-300VDC 4 = 24VDC (10-36VDC), pluggable terminal block 5 = 48VDC (36-59VDC), pluggable terminal block 6 = 88-300VDC or 85-264VAC, pluggable terminal block P2: PoE Power Supply 5 = 48VDC (36-59VDC) PoE Power Supply Mount: Mounting Options A = No mounting hardware D = 19” rack mount kit E = DIN and panel mount kit F = 19” rack, DIN and panel mount kit Main: Ethernet and Power Connectors B = Ethernet rear; LED panel front; power connector rear C = Ethernet front; LED panel front; power connector rear D = Ethernet rear; LED panel top; power connector rear E = Ethernet front; LED panel top; power connector rear MOD: Manufacturing Modifications 0 = None 1 = Conformal coating S1: Port 01 = 4 x RS232/RS422/RS485 via DB9 02 = 4 x RS232/RS422/RS485 via RJ45 03 = 4 x Fiber Serial Interface (ST Connector) 04 = 4 x RS232/RS422/RS485 & IRIG-B via DB9 05 = 4 x RS232/RS422/RS485 & IRIG-B via RJ45 S2, S3, S4: Serial Port Modules for slots 2,3,4 00 = none 01 = 4 x RS232/RS422/RS485 via DB9 02 = 4 x RS232/RS422/RS485 via RJ45 03 = 4 x Fiber Serial Interface (ST Connector) 04 = 4 x RS232/RS422/RS485 & IRIG-B via DB9 05 = 4 x RS232/RS422/RS485 & IRIG-B via RJ45 S5: Ethernet Modules for Slots 5 00 = none 01 = 2 x 10/100T x PoE ports 02 = 2 x 10FL – Multimode, 850 nm, ST 03 = 2 x 100FX - Multimode, 1300nm, ST 04 = 2 x 100FX - Multimode, 1300nm, SC 05 = 2 x 100FX - Multimode, 1300nm, LC 06 = 2 x 100FX - Multimode, 1300nm, MTRJ 07 = 2 x 100FX - Singlemode, 1300nm, ST, 20km 08 = 2 x 100FX - Singlemode, 1300nm, SC, 20km 09 = 2 x 100FX - Singlemode, 1300nm, LC, 20km 10 = 2 x 100FX - Singlemode, 1300nm, SC, 50km 11 = 2 x 100FX - Singlemode, 1300nm, LC, 50km 12 = 2 x 100FX - Singlemode, 1300nm, SC, 90km 13 = 2 x 100FX - Singlemode, 1300nm, LC, 90km 14 = 1 x IRIG-B in (BNC), 1 x IRIG-B out (BNC) S6: PoE Ethernet Modules for Slot 6 F00 = 2 x 10/100 BaseTx PoE Ports Modular Serial Device Server with Integrated Power Over Ethernet (PoE), 128-bit Encryption RUGGEDCOM RS416P 11 Example Order Codes 6GK6041-6PT24-5FC1-Z A01+B05+C02+D03+E06+F00 Unit Power Supply: 24VDC (10-36VDC), pluggable terminal block, 48VDC (36-59VDC), 19” Rack, DIN and panel mount kit, Ethernet on front, LED panel on front, power connector on rear, Conformal Coating, S1: 4 x RS232/RS422/RS485 via DB9, S2: 4 x RS232/RS422/RS485 &IRIG-B via RJ45 1, S3: 4 x RS232/RS422/RS485 via RJ45, S4: 4 x Fiber Serial Interface (ST Connector), S5: 2 x 100FX – Multimode, 1300nm, MTRJ, S6: 2 x 10/100 BaseTx PoE Ports 6GK6041-6PT22-5DC0-Z A03+B00+C00+D00+E00+F00 Unit Power Supply: 48VDC (36-59VDC), PoE Power Supply: 48VDC (36-59),19” Rack Mount Kit, Ethernet on front, LED panel on front, power connector on rear, S1: 4 x Fiber Serial Interface (ST Connector), s6: 2 x 10/100 BaseTx PoE Ports Accessories/Options 6GK6000-8MQ00-0AA0 – Cable support bracket (one) 6GK6000-8BA00-0AA0 – Power Cable with Lugs RS1600 12 RUGGEDCOM RS416P Modular Serial Device Server with Integrated Power Over Ethernet (PoE), 128-bit Encryption Siemens Industry, Inc. 5300 Triangle Parkway Norcross, GA 30092 1-800-241-4453 [email protected] usa.siemens.com/ruggedcom Subject to change without prior notice. All rights reserved. ©2015 Siemens Industry, Inc. The information provided in this brochure contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. All product designations may be trademarks or product names of Siemens or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.