RS900W

Product Overview
RUGGEDCOM RS900W
Wireless Ethernet With Integrated 8-port Managed Switch,
128-bit Encryption
The wireless RUGGEDCOM RS900W from Siemens is a utility
grade Ethernet switch which integrates an IEEE 802.11b/g
wireless access point, with a fully managed wired 8-Port
Ethernet switch providing six Fast Ethernet copper only ports
and two optional copper or fiber ports. With the installation
of the RS900W wireless access point, a network designer
will achieve the integration of wired and wireless networks.
The RS900W can be configured as an access point, client, or
bridge device.
Designed to operate reliably in harsh environments
the RS900W provides a high level of immunity to
electromagnetic interference and heavy electrical surges
typical of environments found in electric utility substations,
curb side traffic control cabinets, and factory floors. An
operating temperature range of -40°C to +85°C coupled
with hazardous location compliance, optional conformal
coating and a galvanized steel enclosure allows the RS900W
to be placed in almost any location.
WPA2/802.11i with AES support. Static authentication support
is provided by WPA-PSK. For additional centralized control,
the RS900W also supports IEEE 802.1X/RADIUS for wireless
user traffic and distributing dynamic encryption keys.
The embedded Rugged Operating System (ROS) provides
advanced networking features such as Enhanced Rapid
Spanning Tree (eRSTP), VLAN, Quality of Service, and a full
array of intelligent functionality and advanced cyber security
features for high network availability and manageability.
All RUGGEDCOM products are backed by a five year warranty
and unsurpassed technical support.
The RS900W functions as a standalone IEEE 802.11b/g access
point for wireless clients providing wireless data rates of up
to 54Mbps. All wireless communications are protected by
the very latest “robust security network” features including
strong encryption protocols using WPA with TKIP and even
usa.siemens.com/ruggedcom
Features and Benefits
■ 6 - Fast Ethernet ports (10/100BaseTX)
■ Optional 2 - Fast Ethernet ports (10/100BaseTX
or 100BaseFX)
■ Multiple fiber connector types
■ -40°C to +85°C operating temperature (no fans)
■ 20 AWG galvanized steel enclosure
■ DIN or panel mounting options provide secure
mechanical reliability
■ Hazardous Locations: Class 1, Division 2
Cyber Security Features
Rugged Operating System (ROS) Features
■ WPA (Wi-Fi Protected Access) with TKIP for enhanced
security and encryption
■ WPA2/802.11i with CCMP for robust security and
128-bit AES encryption
■ IEEE 802.1X/RADIUS using EAP-PEAP for secure “enterprise class” authentication configuration
■ Pre-shared Key Mode (PSK) for “personal” mode
authentication configuration
■ Multi-level user passwords
■ SSH/SSL/SFTP (128-bit encryption)
■ Enable/disable ports, MAC based port security
■ Port based network access control (802.1x)
■ VLAN (802.1Q) to segregate and secure network traffic
■ RADIUS centralized password management
■ SNMPv3 authentication and 56-bit encryption
■ Simple plug and play operation - automatic learning,
negotiation, and crossover detection
■ MSTP (802.1Q - 2005, formerly 802.1s)
■ RSTP (802.1D-2004) and Enhanced Rapid Spanning Tree
(eRSTP) network fault recovery (<5ms)
■ Quality of Service (802.1p) for real-time traffic
■ VLAN (802.1Q) with double tagging and GVRP support
■ Link aggregation (802.3ad)
■ IGMP snooping for multicast filtering
■ Port rate limiting and broadcast storm limiting
■ Port configuration, status, statistics, mirroring, security
■ SNTP time synchronization (client and server)
Ethernet Ports
Rugged Rated for Reliability in Harsh
Environments
■ Immunity to EMI and heavy electrical surges
- Meets IEEE 1613 (electric utility substations)
- Exceeds IEC 61850-3 (electric utility substations)
- Exceeds IEC 61800-3 (variable speed drive systems)
- Exceeds IEC 61000-6-2 (generic industrial)
- Exceeds NEMA TS-2 (traffic control equipment)
2
RUGGEDCOM RS900W
Universal Power Supply Options
■ Fully integrated power supply (no external adaptors)
■ Popular low-voltage DC ranges: 24VDC (10-36VDC) or 48VDC (36-72VDC)
■ Universal high-voltage range: 88-300VDC or 85-264VAC
■ CSA/UL 60950 safety approved to +85°C
■ Screw connection terminal blocks ensure reliable
maintenance free connections
Wireless Ethernet With Integrated 8-port Managed Switch, 128-bit Encryption
RUGGEDCOM Wireless RS900W
Operating
Temperature
Antenna
„ -40°C to +85°C
„No fans
„ Standard 3dBi
„ Various antenna option
packages available
Hazardous Location
Compliance
Rugged Construction
„20 AWG. galvanized
steel enclosure
„Conformal coating
(optional)
„ Class 1, Division 2
Optional Ports
„ Up to 2 additional ports
„Fast 10/100BaseTX
or 10/100BaseFX
„Fiber optical (MMF/SMF)
„Multiple fiber connector types
Integrated Power Supply
„Universal high-voltage
range: 88-300VDC or
85–264VAC
„Popular low voltage DC ranges:
24VDC (10-36VDC)
48VDC (36-72VDC)
„Dual Isolated DC
power inputs
Fast Ethernet
Ports
„ 6 – Fast Ethernet ports
(10/100BaseTX)
Critical Alarm Relay
Mounting Options
„DIN rail
„Panel mount
„Form-C failsafe contact relay:
1A@30VDC
Wireless Specifications
■ IEEE 802.11b/g compliant provides simultaneous support
for both IEEE802.11b and IEEE802.11g wireless clients.
■ Can be configured as an access, client or bridge device
■ Antenna type: Removable, upgradeable 3dBi Antenna
with R-SMA (male) connector
■ Operating channels/frequency-range:
-11 channels, 2.400 - 2.4720 Ghz (US, Canada)
- 13 channels, 2.400 - 2.4835 Ghz (ETSI)
- 14 channels, 2.400 - 2.4970 Ghz (Japan)
■ Data rates:
-IEEE 802.11b: 11/5.5/2/1 Mbps with automatic failback
-IEEE 802.11g: 54/48/36/24/18/12/9/6 Mbps with automatic failback
■ Modulation technology:
-IEEE 802.11b: DSSS over CCK (11/5 Mbps), DQPSK
(2 Mbps), DBPSK (1 Mbps)
-IEEE 802.11g: OFDM over 64QAM, 16QAM, QPSK, BPSK
■ Transmit power:
- IEEE 802.11b: 20dBm nominal @ 11 Mbps
-IEEE 802.11g: 16dBm nominal @ 54 Mbps
■ Receiver sensitivity:
- IEEE 802.11b: -88dBm @ 11 Mbps with 8% FER
- IEEE 802.11g: -74dBm @ 54 Mbps with 10% FER
Wireless Ethernet With Integrated 8-port Managed Switch, 128-bit Encryption
RUGGEDCOM RS900W
3
Network Architecture
Remote Access
from Laptop
Security Perimeter
Field Devices
RUGGEDCOM
RS910W
Access Point
Control Room
RUGGEDCOM
RS900W
Fiber Optic
RUGGEDCOM
RS910W
RUGGEDCOM
RSG2100
SCADA Servers
RUGGEDCOM
RS400
SCADA Servers
Industrial Ethernet
(Copper)
4
RUGGEDCOM RS900W
Industrial Ethernet
(Fiber Optic)
Serial
Cellular
Wireless Ethernet With Integrated 8-port Managed Switch, 128-bit Encryption
ROS Features
Cyber Security
Cyber security is an urgent issue in many industries where
advanced automation and communications networks play
a crucial role in mission critical applications and where high
reliability is of paramount importance. Key ROS features that
address security issues at the local area network
level include:
■ Passwords – Multi-level user passwords secures switch
against unauthorized configuration
■ SSH / SSL – Extends capability of password protection
to add 128-bit encryption of passwords and data as they
cross the network
■ Enable/Disable ports – Capability to disable ports so
that traffic can not pass
■ 802.1Q VLAN – Provides the ability to logically segregate
traffic between predefined ports on switches
■ MAC based port security – The ability to secure ports
on a switch so only specific Devices / MAC addresses
can communicate via that port
■ 802.1x Port based network access control – The ability
to lock down ports on a switch so that only authorized
clients can communicate via this port
■ RADIUS – authentication service using MD5 hash and
providing centralized password management
■ SNMPv3 – encrypted authentication access security and data encryption (CBC-DES with 56-bit encryption key)
■ Secure socket layer – Web-based management using
SSL with data encryption (128-bit encryption key)
■ RSA – 1024 bit key for key management and key
exchange
■ TACACS+ – Terminal Access Control and Accounting Services. Client provides encrypted authentication
and authorization
■ Point to Point (PPP) – using CHAP (MD5 Hash)
authentication service
■ SFTP – Secure File Transfer Protocol using SSH encryption
The ROS cyber security features are included to help address
the various industry specific security standards such as
NERC CIP, ISA S99, AGA 12, IEC 62443, ISO 17799:2005
and PCSRF SPP-ICS.
Enhanced Rapid Spanning Tree Protocol
(eRSTP)
RUGGEDCOM eRSTP allows the creation of fault-tolerant
ring and mesh Ethernet networks that incorporate
redundant links that are ‘pruned’ to prevent loops. eRSTP
yields worst-case fault recovery 1 of 5ms times the ‘bridge
diameter’ and allows rings of up to 160 switches. For
example, a ring of ten switches will have fault recovery
times under 50ms. eRSTP implements both STP and
RSTP to ensure interoperability with commercial switches
unlike other proprietary ‘ring’ solutions.
Quality of Service (IEEE 802.1p)
Some networking applications such as real-time control
or VoIP (voice over IP) require predictable arrival times for
Ethernet frames. Switches can introduce latency in times
of heavy network traffic due to the internal queues that
buffer frames and then transmit on a first come first serve
basis. ROS supports ‘Class of Service’ in accordance with
IEEE 802.1p that allows time critical traffic to jump ahead
to the front of the queue thus minimizing latency and
reducing jitter to allow such demanding applications to
operate correctly. ROS allows priority classification by
port, tags, MAC address, and IP type of service (ToS). A
configurable “weighted fair queuing” algorithm controls
how frames are emptied from the queues.
VLAN (IEEE 802.1Q)
Virtual local area networks (VLAN) allow the segregation
of a physical network into separate logical networks with
independent broadcast domains. A measure of security is
provided since hosts can only access other hosts on the
same VLAN and traffic storms are isolated. ROS supports
802.1Q tagged Ethernet frames and VLAN trunks. Port
based classification allows legacy devices to be assigned to
the correct VLAN. GVRP support is also provided to simplify
the configuration of the switches on the VLAN.
Link Aggregation (802.3ad)
The link aggregation feature provides the ability to
aggregate several Ethernet ports into one logical link (port
trunk) with higher bandwidth. This provides an inexpensive
way to set up a high speed backbone to improve network
bandwidth. This feature is also known as “port trunking,”
“port bundling,” “port teaming,” and “Ethernet trunk.”
IGMP Snooping
ROS uses IGMP snooping (Internet Group Management
Protocol v1&v2) to intelligently forward or filter multicast
traffic streams (e.g. MPEG video) to or from hosts on the
network. This reduces the load on network trunks and
prevents packets from being received on hosts that are
not involved. ROS has a very powerful implementation
of IGMP snooping that:
■ Can be enabled on a per VLAN basis
■ Detects and filters all multicast streams regardless of whether subscribers exist
■ Supports “router-less” operation by supporting an
“active” mode
■ Restores traffic streams immediately after an RSTP
topology change
1 eRSTP fault recovery times may be approximated as follows:
For 100 Mbps, fault recovery performance is <5ms/hop
For 1,000 Mbps, fault recovery performance is <5ms/hop + 20ms
Wireless Ethernet With Integrated 8-port Managed Switch, 128-bit Encryption
RUGGEDCOM RS900W
5
ROS Features
SNMP (Simple Network Management Protocol)
Loss of Link Management
SNMP provides a standardized method for network
management stations to interrogate devices from different
vendors. SNMP versions supported by ROS are v1, v2c, and
v3. SNMPv3, in particular, provides security features such as
authentication, privacy with data encryption (CBC-DES with
56-bit encryption key) and access control not present in
earlier SNMP versions. ROS also supports numerous standard
MIBs (Management Information Base) allowing for easy
integration with any network management system (NMS).
Some intelligent electronic devices (IEDs) have dual fiber
optic ports with automatic failover to a backup port should
the primary fail. ROS ensures this mechanism works reliably
under all failure modes by appropriately disabling link signals
when required. ROS also flushes learned MAC addresses to
ensure the failover occurs quickly.
A feature of SNMP supported by ROS is the ability to
generate “traps” upon system events. RUGGEDCOM NMS, the
RUGGEDCOM management solution, can record traps from
multiple devices providing a powerful network troubleshooting
tool. It also provides a graphical visualization of the network
and is fully integrated with all RUGGEDCOM products.
Port Configuration and Status
ROS allows individual ports to be ‘hard’ configured for speed,
duplex, auto-negotiation, flow control and more. This allows
proper connection with devices that do not negotiate or have
unusual settings. Detailed status of ports with alarm and SNMP
trap on link problems aid greatly in system troubleshooting.
Port Statistics and RMON (Remote Monitoring)
SNTP automatically synchronizes the internal clock of all
ROS devices on the network. This allows for correlation
of time stamped events for troubleshooting.
ROS provides continuously updating statistics per port that
provide both ingress and egress packet and byte counters as
well as detailed error figures. Also provided is full support
for the RMON statistics, history, alarms, and event groups.
RMON allows for very sophisticated data collection, analysis
and detection of traffic patterns.
SCADA and Industrial Automation
Event Logging and Alarms
ROS contains features that optimize network performance
and simplify switch management based on the unique
requirements found in SCADA and industrial automation
applications. Features such as Modbus TCP management
for retrieval of switch data using the ubiquitous Modbus
protocol and DHCP Option 82, a Rockwell Automation ODVA
requirement for IP address assignment based on the location
of the end device, provide capabilities not found in typical
“commercial” or “office grade” Ethernet switches.
ROS records all significant events to a non-volatile system
log allowing forensic troubleshooting. Events include link
failure and recovery, unauthorized access, broadcast storm
detection, and self-test diagnostics among others. Alarms
provide a snapshot of recent events that have yet to be
acknowledged by the network administrator. An external
hardware relay is de-energized during the presence of critical
alarms allowing an external controller to react if desired.
SNTP (Simple Network Time Protocol)
Port Based Network Access Control (802.1x)
ROS supports the IEEE 802.1x standard that defines a
mechanism for port-based network access control which
provides a means of authenticating and authorizing
devices attached to LAN ports.
Port Rate Limiting
ROS supports configurable rate limiting per port to limit
unicast and multicast traffic. This can be essential to managing
precious network bandwidth for service providers. It also
provides edge security for denial of service (DoS) attacks.
Broadcast Storm Filtering
Broadcast storms wreak havoc on a network and can cause
attached devices to malfunction. This could be disastrous on
a network with mission critical equipment. ROS limits this by
filtering broadcast frames with a user-defined threshold.
Port Mirroring
ROS can be configured to duplicate all traffic on one port to
a designated mirror port. When combined with a network
analyzer, this can be a powerful troubleshooting tool.
6
RUGGEDCOM RS900W
HTML Web Browser and Telnet/SSH User
Interfaces
ROS provides a simple, intuitive user interface for configuration
and monitoring via a standard graphical web browser or via
Telnet/SSH. All system parameters include detailed on-line
help to make setup a breeze. ROS, presents a common look
and feel and standardized configuration process allowing
easy migration to other RUGGEDCOM managed products.
Configuration Via ASCII Text File
All configuration parameters are stored in an ASCII formatted
text file that can easily be transferred via TFTP, SFTP or
Xmodem. The configuration file can be saved for backup
purposes and easily manipulated by a text editor. The same
text file can be downloaded to the switch at a later date in
order to re-configure or restore a previous configuration.
Command Line Interface (CLI)
A command line interface can be used in conjunction with
remote shell to automate data retrieval, configuration
updates, and firmware upgrades. A powerful SQL-like
capability allows expert users the ability to selectively
retrieve or manipulate any parameters the device has
to offer.
Wireless Ethernet With Integrated 8-port Managed Switch, 128-bit Encryption
EMI and Environmental Type Tests
IEC 61850-3 EMI Type Tests
Test
Description
Test Levels
Severity Levels
Enclosure contact
Enclosure air
Enclosure ports
Signal ports
D.C. power ports
A.C. power ports
Earth ground ports 3
+/- 8kV
+/- 15kV
20 V/m
+/- 4kV @ 2.5kHz
+/- 4kV
+/- 4kV
+/- 4kV
4
4
Note 1
Note 1
4
4
4
Signal ports
+/-4kV line-to-earth, +/- 2kV line-to-line
4
D.C. power ports
A.C. power ports
Signal ports
D.C power ports
A.C power ports
Earth ground ports 3
Signal ports
D.C. power ports
A.C. power ports
Signal ports
D.C. power ports
D.C. power ports
Signal ports
D.C. power ports
+/-2kV line-to-earth, +/- 1kV line-to-line
+/- 4kV line-to-earth, +/- 2kV line-to-line
10V
10V
10V
10V
40 A/m continuous, 1000 A/m for 1 s
1000 A/m for 1 s
30% for 0.1s, 60% for 0.1s, 100% for 0.05s
30% for 1 period, 60% for 50 periods
100% for 5 periods, 100% for 50 periods
2.5kV common, 1kV diff. mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
30V Continuous, 300V for 1s
30V Continuous, 300V for 1s
10%
2k V AC (Fail-safe relay output)
1.5V DC
3
4
3
3
3
3
Note 1
5
N/A
N/A
N/A
3
3
3
4
4
3
N/A
N/A
A.C. power ports
Signal ports
D.C. Power ports
A.C. Power ports
2k V AC
5kV (Fail-safe relay output)
5kV
5kV
N/A
N/A
N/A
N/A
Enclosure contact
Enclosure air
Enclosure ports
Test Levels
+/-2kV, +/-4kV, +/- 8kV
+/-4kV, +/-8kV, +/-15kV
35 V/m
Severity Levels
N/A
N/A
N/A
Signal ports
D.C. power ports
A.C. power ports
Earth ground ports 3
Signal ports
D.C. power ports
A.C. power ports
Signal ports
D.C. power ports
A.C. power ports
Signal ports
D. C. power ports
A. C. power ports
+/-4kV @ 2.5kHz
+/-4kV
+/-4kV
+/-4kV
2.5kV common mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
5kV (Fail-safe relay output)
5kV
5kV
2k V AC
1.5k V DC
2k V AC
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Environmental Type Tests
Test
Description
IEC 60068-2-1
Cold temperature
Test Ad
Test Levels
-40°C, 16 hours
Severity Levels
N/A
IEC 60068-2-2
Dry heat
Test Bd
+85°C, 16 hours
N/A
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
Humidity (damp heat, cyclic) Test Db
Vibration
Test Fc
Shock
Test Ea
95% (non-condensing), 55°C , 6 cycles
2g @ (10 - 150) Hz
30g @ 11mS
N/A
Class 2 2
Class 2 2
IEC 61000-4-2
ESD
IEC 61000-4-3
Radiated RFI
IEC 61000-4-4
Burst (fast transient)
IEC 61000-4-5
Surge
IEC 61000-4-6
Induced (conducted) RFI
IEC 61000-4-8
Magnetic field
IEC 61000-4-29
Voltage dips and interrupts
IEC 61000-4-11
IEC 61000-4-12
Damped oscillatory
IEC 61000-4-16
Mains frequency voltage
IEC 61000-4-17
Ripple on D.C. power supply
IEC 60255-5
Dielectric strength
IEC 60255-5
Enclosure ports
D.C. power ports
H.V. Impulse
A.C. power ports
IEEE 1613 (C37.90.x) EMI Immunity Type Tests 2
Test
Description
IEEE C37.90.3
ESD
IEEE C37.90.2
Radiated RFI
IEEE C37.90.1
Fast transient
IEEE C37.90.1
Oscillatory
IEEE C37.90
H.V. impulse
IEEE C37.90
Dielectric strength
1 RUGGEDCOM
specified severity levels.
2 refers to “Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are
very high, (e.g. shipboard application and for severe transportation conditions”).
3 Only applicable to functional earth connections separated from the safety earth connection.
2 Class
Wireless Ethernet With Integrated 8-port Managed Switch, 128-bit Encryption
RUGGEDCOM RS900W
7
Technical Specifications
Power Supply
■ Power consumption: 10W max
■ 24VDC: 10-36VDC, 0.4A
■ 48VDC: 36-72VDC, 0.2A
■ HI voltage AC/DC: 88-300VDC, 85-264VAC, 0.1A
Critical Alarm Relay
■ Form-C failsafe contact relay:
1A@30VDC
Physical Dimensions
■ Height: 7.4” (188mm)
■ Width: 2.6” (66mm)
■ Depth: 5.0” (127mm)
■ Weight: 1.22 kg
■ Ingress Protection: IP40 (1mm objects)
■ Enclosure: 20 AWG galvanized steel enclosure
■ Mounting: DIN rail or panel mounted
Switch Properties
■ Switching method: Store and forward
■ Switching latency: 8 us (100Mbps)
■ Switching bandwidth: 1.8 Gbps
■ MAC address table size: 16kbytes
■ Priority queues: 4
■ Frame buffer memory: 1 Mbit
■ Simultaneous VLANs: 255
■ VLAN ID range: 1 to 4094
■ IGMP and static multicast groups: 256
■ Port rate limiting: 128kbps, 256, 512, 4, 8Mbps
■ No head of line blocking
Regulatory Approvals
■ ISO: Designed and manufactured using a ISO9001:
2000 certified quality program
■ CE marking
■ Emissions: FCC Part 15 (Class A), EN55022 (CISPR22 Class A)
■ Safety: cCSAus (Compliant with CSA C22.2 No. 60950,
UL 60950, EN60950)
■ Laser eye safety (FDA/CDRH): Complies with 21 CFR
Chapter 1, Subchapter J
Network Management
■ HTTPS graphical web-based, SSL (128-bit encryption)
■ SNMP v1, v2c, v3 (56-bit encryption)
■ Telnet, VT100, SSH/SFTP (128-bit encryption)
■ Command Line Interface (CLI)
■ RSA key management (1024 bit key)
■ Authentication and accounting - TACACS+ (encrypted),
RADIUS client, PPP
Warranty
■ 5 Years – Applicable to design and manufacturing related
product defects.
8
RUGGEDCOM RS900W
EMI Immunity and Environmental Compliance
■IEC 61000-6-2 Industrial (Generic)
■IEC 61800-3 Industrial (Variable Speed Drive Systems)
■ IEC 61850-3 Electric Utility Substations
■ IEEE 1613 Electric Utility Substations
■ NEMA TS 2 Traffic Control Equipment
■ Hazardous Locations: Class 1, Division 2
IEEE Compliance
■ 802.3-10BaseT
■802.3u-100BaseTX, 100BaseFX
■802.3x-Flow Control
■802.3z-1000BaseLX
■802.3ab-1000BaseTX
■802.3ad-Link Aggregation
■802.1d-MAC Bridges
■802.1d-Spanning Tree Protocol
■802.1p-Class of Service
■802.1Q-VLAN Tagging
■802.1w-Rapid Spanning Tree Protocol
■802.1x-Port Based Network Access Control
■802.1Q-2005 (formerly 802.1s) MSTP
IETF RFC Compliance
■RFC768-UDP
■ RFC783-TFTP
■ RFC791-IP
■RFC792-ICMP
■RFC793-TCP
■ RFC826-ARP
■ RFC854-Telnet
■RFC894-IP over Ethernet
■RFC1112-IGMP v1
■ RFC1519-CIDR
■ RFC1541-DHCP (client)
■ RFC2030-SNTP
■RFC2068-HTTP
■RFC2236-IGMP v2
■ RFC2284-EAP
■RFC2475-Differentiated Services
■RFC2865-RADIUS
■RFC3414-SNMPv3-USM
■RFC3415-SNMPv3-VACM
IETF SNMP MIBS
■ RFC1493-BRIDGE-MIB
■RFC1907-SNMPv2-MIB
■RFC2012-TCP-MIB
■RFC2013-UDP-MIB
■RFC2578-SNMPv2-SMI
■RFC2579-SNMPv2-TC
■RFC2819-RMON-MIB
■RFC2863-IF-MIB
■draft-ietf-bridge-rstpmib-03-BRIDGE-MIB
■draft-ietf-bridge-bridgemib-smiv2-03-RSTP-MIB
■IANAifType-MIB
Wireless Ethernet With Integrated 8-port Managed Switch, 128-bit Encryption
Fiber Specifications and Dimension Drawings
Fiber Optical Specifications
Parameter
RUGGEDCOM
RS900W
Fiber Port Type
Installation
Guide
Mode
Chapter 5
Multimode
Singlemode
Singlemode
Dimension
Drawings
Singlemode
Connector
MTRJ, ST, SC
LC, SC, ST
LC, SC, ST
LC, SC, ST
Typical Dist. (km)
2
20
50
90
Dimension Drawings
Optical Wavelength (nm)
1310
1310
1310
1310
Cable Size Core/Cladding (um)
50 / 125 or 62.5 / 125
8 / 125 or 9 / 125
8 / 125 or 9 / 125
8 / 125 or 9 / 125
TX Power (Min/Max) (dBm)
-9.5 / -4
-9 /-3
-7 / -3
0/5
RX Sensitivity (dBm)
-15.7
-15.5
-2.5
-2.5
RX Saturation (dBm)
-33.5
-32
-37
-39
17
16.5
34.5
41.5
NOTE
Typical Budget
(dB)
All dimensions
are in on
millimeters,
unlessConsult
otherwise
Longer segment
lengths dependent
fiber specifications.
factory stated.
for further details.
116.59
187.96
168.66
65.13
99.06
7.87
Figure
15:dimensions
Overall Dimensions
Overall
All dimensions are in millimeters, unless otherwise stated.
Wireless Ethernet With Integrated 8-port Managed Switch, 128-bit Encryption
RUGGEDCOM RS900W
9
Chapter 5
RUGGEDCOM RS900W
Dimension Drawings
Installation Guide
Dimension Drawings
134.09
101.60
11.18
83.82
183.89
194.06
13.64
78.74
120.65
Figure
16:DIN
Panel
DINdimensions
Rail Mount Dimensions
Panel
and
railand
mount
All dimensions are in millimeters, unless otherwise stated.
24
10
RUGGEDCOM RS900W
Wireless Ethernet With Integrated 8-port Managed Switch, 128-bit Encryption
Order Codes
6GK60900AW2
_______ - 0 - _______ - A - ________ - Z _______ + ______
PS1
Mount
PS1: Power Supply 1
1 = 24 VDC (10-36 VDC)
2 = 48 VDC (36-72 VDC)
3 = 88-300VDC or 85-264VAC
Mount: Mounting Options
A = No mounting option
B = DIN rail mounting
C = Panel mounting
MOD: Manufacturing Modifications
0 = None
1 = Conformal coating
P7P8: Port 7 and Port 8 Options
A00 = None
A01 = 1 x 10/100BaseTX 1 x 10/100BaseTX (if selected,
P7 & P8 must both be TX)
A02 = 1 x 100BaseFX - Multimode, MTRJ connector, 1 x none
A03 = 1 x 100BaseFX - Multimode, LC connector 1 x none
A04 = 1 x 100BaseFX - Multimode, SC connector 1 x none
A05 = 1 x 100BaseFX - Multimode, ST connector 1 x none
A06 = 1 x 100BaseFX - Singlemode, ST connector,
20km 1 x none
A07 = 1 x 100BaseFX - Singlemode, LC connector,
20km 1 x none
A08 = 1 x 100BaseFX - Singlemode SC connector,
20km 1 x none
A09 = 1 x 100BaseFX - Multimode, MTRJ connector
1 x 100BaseFX - Multimode, MTRJ connector
A10 = 1 x 100BaseFX - Multimode, LC connector
1 x 100BaseFX - Multimode, LC connector
A11 = 1 x 100BaseFX - Singlemode LC connector,
50km 1 x none
A12 = 1 x 100BaseFX - Multimode, SC connector
1 x 100BaseFX - Multimode, SC connector
A13 = 1 x 100BaseFX - Multimode, ST connector
1 x 100BaseFX - Multimode, ST connector
A14 = 1 x 100BaseFX - Multimode, LC connector
1 x 100BaseFX - Singlemode, LC connector, 20km
A15 = 1 x 100BaseFX - Multimode, ST connector
1 x 100BaseFX - Singlemode, ST connector, 20km
A16 = 1 x 100BaseFX - Multimode, SC connector
1 x 100BaseFX - Singlemode SC connector, 20km
A17 = 1 x 100BaseFX - Multimode, ST connector
1 x 100BaseFX - Singlemode SC connector, 20km
A18 = 1 x 100BaseFX - Singlemode, ST connector, 20km
1 x 100BaseFX - Singlemode, ST connector, 20km
A19 = 1 x 100BaseFX - Singlemode, LC connector, 20km
1 x 100BaseFX - Singlemode, LC connector, 20km
MOD
P7P8
WVV
A20 = 1 x 100BaseFX - Singlemode SC connector, 20km
1 x 100BaseFX - Singlemode SC connector, 20km
A21 = 1 x 100BaseFX - Singlemode LC connector, 50km
1 x none
A22 = 1 x 100BaseFX - Singlemode LC connector, 50km
1 x 100BaseFX - Singlemode LC connector, 50km
A23 = 1 x 100BaseFX - Singlemode, LC connector, 20km
1 x 100BaseFX - Singlemode LC connector, 90km
A24 = 1 x 100BaseFX - Singlemode LC connector, 90km
1 x 100BaseFX - Singlemode LC connector, 90km
A25 = 1 x 100BaseFX - Singlemode SC connector, 50km
1 x none
A26 = 1 x 100BaseFX - Singlemode, LC connector, 20km
1 x 100BaseFX - Singlemode LC connector, 50km
A27 = 1 x 100BaseFX - Singlemode SC connector, 90km
1 x none
A28 = 1 x 100BaseFX - Singlemode SC connector, 20km
1 x 100BaseFX - Singlemode SC connector, 50km
A29 = 1 x 100BaseFX - Singlemode SC connector, 90km
1 x 100BaseFX - Singlemode SC connector, 90km
A30 = 1 x 100BaseFX - Singlemode SC connector, 50km
1 x 100BaseFX - Singlemode SC connector, 90km
A31 = 1 x 100BaseFX - Singlemode SC connector, 50km
1 x 100BaseFX - Singlemode SC connector, 50km
WVV: Wireless
B01 = 802.11 – US (North America)
B02 = 802.11 – EU (European Union)
B03 = 802.11 – CH (China)
B04 = 802.11 – AU (Australia)
B05 = 802.11 – IN (India)
Power cables
6GK6000-8BB00-0AA0 – Bare-wire
6GK6000-8BA00-0AA0 – with lugs
Wireless Ethernet With Integrated 8-port Managed Switch, 128-bit Encryption
RUGGEDCOM RS900W
11
Example order codes
6GK6090-0AW21-0BA0-Z A02+B01
24VDC Power Supply, DIN Rail Mount, 1 x 100BaseFX – Multimode,
MTRJ connector, 1 x none, 802.11 - US (North America)
6GK6090-0AW22-0CA0-Z A22+B02
48VDC Power Supply, Panel Mount, Conformal Coating,
1 x 100BaseFX - Singlemode LC connector, 50km
1 x 100BaseFX - Singlemode LC connector, 50km,
802.11 - EU (European Union)
12
RUGGEDCOM RS900W
Wireless Ethernet With Integrated 8-port Managed Switch, 128-bit Encryption
Siemens Industry, Inc.
5300 Triangle Parkway
Norcross, GA 30092
1-800-241-4453
[email protected]
usa.siemens.com/ruggedcom
Subject to change without prior notice.
All rights reserved.
©2015 Siemens Industry, Inc.
The information provided in this brochure contains descriptions or
characteristics of performance which in case of actual use do not
always apply as described or which may change as a result of
further development of the products. An obligation to provide
the respective characteristics shall only exist if expressly agreed in
the terms of contract. Availability and technical specifications are
subject to change without notice.
All product designations may be trademarks or product names
of Siemens AG or supplier companies whose use by third parties
for their own purposes could violate the rights of the owners.