RS930L

Product Overview
RUGGEDCOM RS930L
6-port Managed Ethernet Switch With Dual Port Ethernet Over
VDSL Uplinks, 128-bit Encryption
The RUGGEDCOM RS930L from Siemens is a 6 port utility
grade fully managed Ethernet switch supporting Ethernet
over VDSL (EoVDSL) allowing up to 5km LAN segments over
telephone grade cable (or other legacy serial cabling) at up
to 35Mbps. The RS930L allows for aggregation of Ethernet
enabled devices at a remote location back to the central
control room with EoVDSL using existing telephone grade
cable (or other legacy serial cabling). The RS930L can be
configured with dual EoVDSL interfaces and is ideal for ring
or loop network architecture and is the perfect solution
for bringing Ethernet networking to applications where
existing telephone wiring is already present, thus saving
the considerable cost of installing new network cabling.
Designed to operate reliably in harsh environments the
RS930L provides a high level of immunity to electromagnetic
interference and heavy electrical surges typical of environments
found in electric utility substations, curb side traffic control
cabinets, and factory floors. An operating temperature range
of -40°C to +85°C coupled with hazardous location compliance,
optional conformal coating and a galvanized steel enclosure
allows the RS930L to be placed in almost any location.
and 48VDC power supply inputs for high availability
applications requiring backup power inputs.
The embedded Rugged Operating System (ROS) provides
advanced cyber security features and comprehensive
networking functions, providing a full array of intelligent
functionality for high network availability and manageability.
Coupled with ruggedness and durability that is designed
in from the onset, the RS900L is ideal for creating missioncritical, real-time, control applications where high reliability
and availability is of paramount importance.
All RUGGEDCOM products are backed by a five year warranty
and unsurpassed technical support.
The RS930L provides an integrated power supply with a wide
range of voltages (88-300VDC or 85-264VAC) for worldwide
operability or dual-input, reversible polarity, 12VDC, 24VDC
usa.siemens.com/ruggedcom
Features and Benefits
Ethernet Ports
■ Up to two Ethernet over VDSL (EoVDSL) interfaces
■ 6 fast Ethernet ports (10/100BaseTX)
Ethernet Over VDSL Characteristics
■ Up to 5km LAN segments
■ Symmetric data rates up to 35Mbps
■ Asymmetric data rates up to 40Mbps
■ Automatically selects fastest data rate based on distance and quality of cable
■ Software selectable to be master or slave
■ Frequency Division Multiplexing (FDM)
Cyber Security Features
■ Multi-level user passwords
■ SSH/SSL/SFTP (128-bit encryption)
■ Enable/disable ports, MAC based port security
■ Port based network access control (802.1x)
■ VLAN (802.1Q) to segregate and secure network traffic
■ RADIUS centralized password management
■ SNMPv3 authentication and 56-bit encryption
Rugged Rated for Reliability in Harsh
Environments
■ Immunity to EMI and heavy electrical surges
- Meets IEEE 1613 (electric utility substations)
- Exceeds IEC 61850-3 (electric utility substations)
- Exceeds IEC 61800-3 (variable speed drive systems)
- Exceeds IEC 61000-6-2 (generic industrial)
- Exceeds NEMA TS-2 (traffic control equipment)
2
RUGGEDCOM RS930L
■ -40°C to +85°C operating temperature (no fans)
■ 20 AWG galvanized steel enclosure
■ DIN or panel mounting options provide secure mechanical reliability
■ Hazardous Locations: Class 1, Division 2
Rugged Operating System (ROS) Features
■ Simple plug and play operation – automatic learning,
negotiation, and crossover detection
■ MSTP (802.1Q - 2005, formerly 802.1s)
■ RSTP (802.1D-2004) and Enhanced Rapid Spanning Tree
(eRSTP) network fault recovery (<5ms)
■ Quality of Service (802.1p) for real-time traffic
■ VLAN (802.1Q) with double tagging and GVRP support
■ Link aggregation (802.3ad)
■ IGMP Snooping for multicast filtering
■ Port Rate Limiting and Broadcast Storm Limiting
■ Loss of link management on fiber ports
■ SNTP time synchronization (client and server)
Universal Power Supply Options
■ Fully integrated power supply (no external adaptors)
■ Popular low-voltage DC ranges: 24VDC (10-36VDC) or 48VDC (36-72VDC)
■ Universal high-voltage range: 88-300VDC or 85-264VAC
■ CSA/UL 60950 safety approved to +85°C
■ Screw connection terminal blocks ensure reliable maintenance free connections
6-port Managed Ethernet Switch With Dual Port Ethernet Over VDSL Uplinks, 128-bit Encryption
RUGGEDCOM RS930L
Operating
Temperature
EoVDSL Port
„ -40°C to +85°C
„No fans
„Two EoVDSL ports standard
„RJ11 connector
„Symmetric data rates
up to 35Mbps
Rugged Construction
„20 AWG galvanized
steel enclosure
„Conformal coating
(optional)
Integrated Power
Supply
Fast Ethernet
Ports
„Universal high-voltage
range: 88-300VDC or
85-264VAC
„Popular low voltage
DC ranges:
24VDC, 48VDC
„Dual isolated DC
power inputs
„ 6 – Fast Ethernet ports
(10/100BaseTX)
Critical Alarm Relay
Mounting Options
„Form-C failsafe contact relay:
1A@30VDC
„DIN rail
„Panel mount
6-port Managed Ethernet Switch With Dual Port Ethernet Over VDSL Uplinks, 128-bit Encryption
RUGGEDCOM RS930L
3
Network Architecture
Control Room
RUGGEDCOM
RS930L
Video
Servers
Traffic Control
Servers
VDSL
RUGGEDCOM
RS920L
RUGGEDCOM
RS930L
Up to 40Mbps
Up to 5km
RUGGEDCOM
RS910L
Up to 40Mbps
RUGGEDCOM
RS900L
Up to 100Mbps
Up to 90km
VoIP
Phone
Video
SCADA
Servers
Up to 5km
SCADA
Servers
Serial
VoIP
Phone
Video
SCADA
Servers
Industrial Ethernet
(Copper)
Industrial Ethernet
(Fiber Optic)
Video
SCADA
Servers
Serial
Serial
Serial
Serial
RS900L
RS920L
8 Port Managed Switch with Ethernet over VDSL Uplink
■ 1 Ethernet over VDSL interface
■ Up to 8 fast Ethernet ports
■ Copper and fiber options
■ Use to aggregate Ethernet enabled devices at remote locations back to a central point
Dual Port Ethernet over VDSL with Integrated Dual Port Serial Server
■ 2 Ethernet over VDSL interfaces
■ 2 RS485/RS422/RS232 Serial ports (DB9 or RJ45)
■ Use as a serial drop point for a ring or bus network
topology
RS910L
RS930L
Serial and Ethernet Device Server with Ethernet over
VDSL Uplink
■ 1 Ethernet over VDSL interface
■ 2 RS485/RS422/RS232 Serial ports (DB9 or RJ45)
■ Optional 2 Ethernet ports – copper of fiber
■ Use to network enable legacy serial devices at
remote locations
4
RUGGEDCOM RS930L
6 Port Managed Switch with Dual Port Ethernet over
VDSL Uplink
■ 2 Ethernet over VDSL interfaces
■ 6 Port Managed Ethernet Switch – copper interfaces
■ Use as an Ethernet drop point for a ring or bus
network topology
■ Span over hundreds of kilometers using existing
telephone grade cables
6-port Managed Ethernet Switch With Dual Port Ethernet Over VDSL Uplinks, 128-bit Encryption
ROS Features
Cyber Security
Cyber security is an urgent issue in many industries where
advanced automation and communications networks play a crucial role in mission critical applications and where high
reliability is of paramount importance. Key ROS features that
address security issues at the local area network level include:
■ Passwords – Multi-level user passwords secures switch
against unauthorized configuration
■ SSH / SSL – Extends capability of password protection
to add 128-bit encryption of passwords and data as they cross the network
■ Enable/Disable ports – Capability to disable ports so that traffic can not pass
■ 802.1Q VLAN – Provides the ability to logically segregate
traffic between predefined ports on switches
■ MAC based port security – The ability to secure ports
on a switch so only specific Devices / MAC addresses can communicate via that port
■ 802.1x Port based network access control – The ability to lock down ports on a switch so that only authorized clients can communicate via this port
■ RADIUS – authentication service using MD5 hash and
providing centralized password management
■ SNMPv3 – encrypted authentication access security and data encryption (CBC-DES with 56-bit encryption key)
■ Secure socket layer – Web-based management using
SSL with data encryption (128-bit encryption key)
■ RSA – 1024 bit key for key management and key
exchange
■ TACACS+ – Terminal Access Control and Accounting Services. Client provides encrypted authentication and authorization
■ Point to Point (PPP) – using CHAP (MD5 Hash)
authentication service
■ SFTP – Secure File Transfer Protocol using SSH encryption
The ROS cyber security features are included to help address
the various industry specific security standards such as NERC CIP, ISA S99, AGA 12, IEC 62443, ISO 17799:2005 and PCSRF SPP-ICS.
Enhanced Rapid Spanning Tree Protocol
(eRSTP)
RUGGEDCOM eRSTP allows the creation of fault-tolerant ring and mesh Ethernet networks that incorporate redundant links that are ‘pruned’ to prevent loops. eRSTP yields worst-case fault recovery 1 of 5ms times the ‘bridge diameter’ and allows rings of up to 160 switches. For example, a ring of ten switches will have fault recovery times under 50ms. eRSTP implements both STP and RSTP to ensure interoperability with commercial switches unlike other proprietary ‘ring’ solutions.
Quality of Service (IEEE 802.1p)
Some networking applications such as real-time control or VoIP (voice over IP) require predictable arrival times for Ethernet frames. Switches can introduce latency in times of heavy network traffic due to the internal queues that buffer frames and then transmit on a first come first serve
basis. ROS supports ‘Class of Service’ in accordance with IEEE 802.1p that allows time critical traffic to jump ahead to the front of the queue thus minimizing latency and
reducing jitter to allow such demanding applications to
operate correctly. ROS allows priority classification by port, tags, MAC address, and IP type of service (ToS). A configurable “weighted fair queuing” algorithm controls
how frames are emptied from the queues.
VLAN (IEEE 802.1Q)
Virtual local area networks (VLAN) allow the segregation
of a physical network into separate logical networks with
independent broadcast domains. A measure of security is
provided since hosts can only access other hosts on the
same VLAN and traffic storms are isolated. ROS supports
802.1Q tagged Ethernet frames and VLAN trunks. Port
based classification allows legacy devices to be assigned to
the correct VLAN. GVRP support is also provided to simplify
the configuration of the switches on the VLAN.
Link Aggregation (802.3ad)
The link aggregation feature provides the ability to
aggregate several Ethernet ports into one logical link (port
trunk) with higher bandwidth. This provides an inexpensive
way to set up a high speed backbone to improve network
bandwidth. This feature is also known as “port trunking,”
“port bundling,” “port teaming,” and “Ethernet trunk.”
IGMP Snooping
ROS uses IGMP snooping (Internet Group Management
Protocol v1&v2) to intelligently forward or filter multicast
traffic streams (e.g. MPEG video) to or from hosts on the
network. This reduces the load on network trunks and
prevents packets from being received on hosts that are
not involved. ROS has a very powerful implementation
of IGMP snooping that:
■ Can be enabled on a per VLAN basis
■ Detects and filters all multicast streams regardless of whether subscribers exist
■ Supports “router-less” operation by supporting an
“active” mode
■ Restores traffic streams immediately after an RSTP
topology change
1 eRSTP fault recovery times may be approximated as follows:
For 100 Mbps, fault recovery performance is <5ms/hop
For 1,000 Mbps, fault recovery performance is <5ms/hop + 20ms
6-port Managed Ethernet Switch With Dual Port Ethernet Over VDSL Uplinks, 128-bit Encryption
RUGGEDCOM RS930L
5
ROS Features
SNMP (Simple Network Management Protocol)
Loss of Link Management
SNMP provides a standardized method for network
management stations to interrogate devices from different
vendors. SNMP versions supported by ROS are v1, v2c, and
v3. SNMPv3, in particular, provides security features such
as authentication, privacy with data encryption (CBC-DES
with 56-bit encryption key) and access control not present in
earlier SNMP versions. ROS also supports numerous standard
MIBs (Management Information Base) allowing for easy
integration with any network management system (NMS).
A feature of SNMP supported by ROS is the ability to
generate “traps” upon system events. RUGGEDCOM NMS, the
RUGGEDCOM management solution, can record traps from
multiple devices providing a powerful network troubleshooting
tool. It also provides a graphical visualization of the network
and is fully integrated with all RUGGEDCOM products.
Some intelligent electronic devices (IEDs) have dual fiber
optic ports with automatic failover to a backup port should
the primary fail. ROS ensures this mechanism works reliably
under all failure modes by appropriately disabling link signals
when required. ROS also flushes learned MAC addresses to
ensure the failover occurs quickly.
SNTP (Simple Network Time Protocol)
SNTP automatically synchronizes the internal clock of all
ROS devices on the network. This allows for correlation
of time stamped events for troubleshooting.
SCADA and Industrial Automation
ROS contains features that optimize network performance
and simplify switch management based on the unique
requirements found in SCADA and industrial automation
applications. Features such as Modbus TCP management
for retrieval of switch data using the ubiquitous Modbus
protocol and DHCP Option 82, a Rockwell Automation ODVA
requirement for IP address assignment based on the location
of the end device, provide capabilities not found in typical
“commercial” or “office grade” Ethernet switches.
Port Based Network Access Control (802.1x)
ROS supports the IEEE 802.1x standard that defines a
mechanism for port-based network access control which
provides a means of authenticating and authorizing
devices attached to LAN ports.
Port Rate Limiting
ROS supports configurable rate limiting per port to limit
unicast and multicast traffic. This can be essential to managing
precious network bandwidth for service providers. It also
provides edge security for denial of service (DoS) attacks.
Port Configuration and Status
ROS allows individual ports to be ‘hard’ configured for speed,
duplex, auto-negotiation, flow control and more. This allows
proper connection with devices that do not negotiate or have
unusual settings. Detailed status of ports with alarm and SNMP
trap on link problems aid greatly in system troubleshooting.
Port Statistics and RMON (Remote monitoring)
ROS provides continuously updating statistics per port that
provide both ingress and egress packet and byte counters as
well as detailed error figures. Also provided is full support
for the RMON statistics, history, alarms, and event groups.
RMON allows for very sophisticated data collection, analysis
and detection of traffic patterns.
Event Logging and Alarms
ROS records all significant events to a non-volatile system
log allowing forensic troubleshooting. Events include link
failure and recovery, unauthorized access, broadcast storm
detection, and self-test diagnostics among others. Alarms
provide a snapshot of recent events that have yet to be
acknowledged by the network administrator. An external
hardware relay is de-energized during the presence of critical
alarms allowing an external controller to react if desired.
HTML Web Browser and Telnet/SSH User
Interfaces
ROS provides a simple, intuitive user interface for configuration
and monitoring via a standard graphical web browser or via
Telnet/SSH. All system parameters include detailed on-line
help to make setup a breeze. ROS, presents a common look
and feel and standardized configuration process allowing
easy migration to other RuggedCom managed products.
Configuration Via ASCII Text File
Broadcast storms wreak havoc on a network and can cause
attached devices to malfunction. This could be disastrous on
a network with mission critical equipment. ROS limits this by
filtering broadcast frames with a user-defined threshold.
All configuration parameters are stored in an ASCII formatted
text file that can easily be transferred via TFTP, SFTP or
Xmodem. The configuration file can be saved for backup
purposes and easily manipulated by a text editor. The same
text file can be downloaded to the switch at a later date in
order to re-configure or restore a previous configuration.
Port Mirroring
Command Line Interface (CLI)
Broadcast Storm Filtering
ROS can be configured to duplicate all traffic on one port to
a designated mirror port. When combined with a network
analyzer, this can be a powerful troubleshooting tool.
6
RUGGEDCOM RS930L
A command line interface can be used in conjunction with
remote shell to automate data retrieval, configuration
updates, and firmware upgrades. A powerful SQL-like
capability allows expert users the ability to selectively
retrieve or manipulate any parameters the device has
to offer.
6-port Managed Ethernet Switch With Dual Port Ethernet Over VDSL Uplinks, 128-bit Encryption
EMI and Environmental Type Tests
IEC 61850-3 EMI Type Tests
Test
Description
IEC 61000-4-2
ESD
IEC 61000-4-3
Radiated RFI
IEC 61000-4-4
Burst (fast transient)
IEC 61000-4-5
Surge
IEC 61000-4-6
Induced (conducted) RFI
IEC 61000-4-8
Magnetic field
IEC 61000-4-29
Severity Levels
+/- 8kV
+/- 15kV
20 V/m
+/- 4kV @ 2.5kHz
+/- 4kV
+/- 4kV
+/- 4kV
4
4
Note 1
Note 1
4
4
4
Signal ports
+/-4kV line-to-earth, +/- 2kV line-to-line
4
D.C. power ports
A.C. power ports
Signal ports
D.C power ports
A.C power ports
Earth ground ports 3
Signal ports
D.C. power ports
A.C. power ports
Signal ports
D.C. power ports
D.C. power ports
Signal ports
D.C. power ports
+/-2kV line-to-earth, +/- 1kV line-to-line
+/- 4kV line-to-earth, +/- 2kV line-to-line
10V
10V
10V
10V
40 A/m continuous, 1000 A/m for 1 s
1000 A/m for 1 s
30% for 0.1s, 60% for 0.1s, 100% for 0.05s
30% for 1 period, 60% for 50 periods
100% for 5 periods, 100% for 50 periods
2.5kV common, 1kV diff. mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
30V Continuous, 300V for 1s
30V Continuous, 300V for 1s
10%
2k V AC (Fail-safe relay output)
1.5V DC
3
4
3
3
3
3
Note 1
5
N/A
N/A
N/A
3
3
3
4
4
3
N/A
N/A
A.C. power ports
Signal ports
D.C. Power ports
A.C. Power ports
2k V AC
5kV (Fail-safe relay output)
5kV
5kV
N/A
N/A
N/A
N/A
Enclosure contact
Enclosure air
Enclosure ports
Test Levels
+/-2kV, +/-4kV, +/- 8kV
+/-4kV, +/-8kV, +/-15kV
35 V/m
Severity Levels
N/A
N/A
N/A
Signal ports
D.C. power ports
A.C. power ports
Earth ground ports 3
Signal ports
D.C. power ports
A.C. power ports
Signal ports
D.C. power ports
A.C. power ports
Signal ports
D. C. power ports
A. C. power ports
+/- 4kV @ 2.5kHz
+/- 4kV
+/- 4kV
+/- 4kV
2.5kV common mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
5kV (Fail-safe relay output)
5kV
5kV
2k V AC
1.5k V DC
2k V AC
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Test Ad
Test Bd
Test Db
Test Fc
Test Ea
Test Levels
-40°C, 16 hours
+85°C, 16 hours
95% (non-condensing), 55°C , 6 cycles
2g @ (10 - 150) Hz
30g @ 11mS
Severity Levels
N/A
N/A
N/A
Class 2 2
Class 2 2
Enclosure ports
D.C. power ports
Voltage dips and interrupts
IEC 61000-4-11
IEC 61000-4-12
Damped oscillatory
IEC 61000-4-16
Mains frequency voltage
IEC 61000-4-17
Ripple on D.C. power supply
IEC 60255-5
Dielectric strength
IEC 60255-5
Test Levels
Enclosure contact
Enclosure air
Enclosure ports
Signal ports
D.C. power ports
A.C. power ports
Earth ground ports 3
H.V. impulse
A.C. power ports
IEEE 1613 (C37.90.x) EMI immunity Type Tests 2
Test
Description
IEEE C37.90.3
ESD
IEEE C37.90.2
Radiated RFI
IEEE C37.90.1
Fast transient
IEEE C37.90.1
Oscillatory
IEEE C37.90
H.V. impulse
IEEE C37.90
Dielectric strength
Environmental Type Tests
Test
Description
IEC 60068-2-1
Cold temperature
IEC 60068-2-2
Dry heat
IEC 60068-2-30
Humidity (damp heat, cyclic)
IEC 60255-21-1
Vibration
IEC 60255-21-2
Shock
1 RUGGEDCOM specified severity levels.
2 Class 2 refers to “Measuring relays and
protection equipment for which a very high security margin is required or where the vibration levels are
very high, (e.g. shipboard application and for severe transportation conditions”).
3 Only applicable to functional earth connections separated from the safety earth connection.
6-port Managed Ethernet Switch With Dual Port Ethernet Over VDSL Uplinks, 128-bit Encryption
RUGGEDCOM RS930L
7
Technical Specifications
Power Supply
■ Power consumption: 10W max
■ 24VDC: 10-36VDC, 0.4A
■ 48VDC: 36-72VDC, 0.2A
■ HI voltage AC/DC: 88-300VDC, 85-264VAC, 0.1A
Critical Alarm Relay
■ Form-C failsafe contact relay:
1A@30VDC
■ Height: 7.4” (188 mm)
■ Width: 2.6” (66 mm)
■ Depth: 5.0” (127 mm)
■ Weight: 1.22 kg
■ Ingress protection: IP40 (1mm objects)
■ Enclosure: 20 AWG galvanized steel enclosure
■ Mounting: DIN rail or panel mounted
Switch Properties
■ Switching method: Store and forward
■ Switching latency: 8 us (100Mbps)
■ Switching bandwidth: 1.8 Gbps
■ MAC address table size: 16kbytes
■ Priority queues: 4
■ Frame buffer memory: 1 Mbit
■ Simultaneous VLANs: 255
■ VLAN ID range: 1 to 4094
■ IGMP and static multicast groups: 256
■ Port rate limiting: 128kbps, 256, 512, 4, 8Mbps
■ No head of line blocking
Regulatory Approvals
■ ISO: Designed and manufactured using a ISO9001:
2000 certified quality program
■ CE marking
■ Emissions: FCC Part 15 (Class A), EN55022 (CISPR22 Class A)
■ Safety: cCSAus (Compliant with CSA C22.2 No. 60950,
UL 60950, EN60950)
■ Laser eye safety (FDA/CDRH): Complies with 21 CFR
Chapter 1, Subchapter J
Network Management
■ HTTPS graphical web-based, SSL (128-bit encryption)
■ SNMP v1, v2c, v3 (56-bit encryption)
■ Telnet, VT100, SSH/SFTP (128-bit encryption)
■ Command Line Interface (CLI)
■ RSA key management (1024 bit key)
■ Authentication and accounting – TACACS+ (encrypted),
RADIUS client, PPP
■ 5 Years – Applicable to design and manufacturing related
product defects.
8
RUGGEDCOM RS930L
■IEC 61000-6-2 Industrial (Generic)
■IEC 61800-3 Industrial (Variable Speed Drive Systems)
■ IEC 61850-3 Electric Utility Substations
■ IEEE 1613 Electric Utility Substations
■ NEMA TS 2 Traffic Control Equipment
■Hazardous Locations: Class 1, Division 2
IEEE Compliance
Physical Dimensions
Warranty
EMI Immunity and Environmental Compliance
■ 802.3-10BaseT
■802.3u-100BaseTX, 100BaseFX
■802.3x-Flow Control
■802.3z-1000BaseLX
■802.3ab-1000BaseTX
■802.3ad-Link Aggregation
■802.1d-MAC Bridges
■802.1d-Spanning Tree Protocol
■802.1p-Class of Service
■802.1Q-VLAN Tagging
■802.1w-Rapid Spanning Tree Protocol
■802.1x-Port Based Network Access Control
■802.1Q-2005 (formerly 802.1s) MSTP
IETF RFC Compliance
■RFC768-UDP
■ RFC783-TFTP
■ RFC791-IP
■RFC792-ICMP
■RFC793-TCP
■ RFC826-ARP
■ RFC854-Telnet
■RFC894-IP over Ethernet
■RFC1112-IGMP v1
■ RFC1519-CIDR
■ RFC1541-DHCP (client)
■ RFC2030-SNTP
■RFC2068-HTTP
■RFC2236-IGMP v2
■ RFC2284-EAP
■RFC2475-Differentiated Services
■RFC2865-RADIUS
■RFC3414-SNMPv3-USM
■RFC3415-SNMPv3-VACM
IETF SNMP MIBS
■ RFC1493-BRIDGE-MIB
■RFC1907-SNMPv2-MIB
■RFC2012-TCP-MIB
■RFC2013-UDP-MIB
■RFC2578-SNMPv2-SMI
■RFC2579-SNMPv2-TC
■RFC2819-RMON-MIB
■RFC2863-IF-MIB
■draft-ietf-bridge-rstpmib-03-BRIDGE-MIB
■draft-ietf-bridge-bridgemib-smiv2-03-RSTP-MIB
■IANAifType-MIB
6-port Managed Ethernet Switch With Dual Port Ethernet Over VDSL Uplinks, 128-bit Encryption
Fiber Specifications and Dimension Drawings
Fiber Optical Specifications
Parameter
RUGGEDCOM
RS930L
Fiber Port Type
Installation
Guide
Mode
Chapter 5
Multimode
Singlemode
Singlemode
Dimension
Drawings
Singlemode
Connector
MTRJ, ST, SC
LC, SC, ST
LC, SC, ST
LC, SC, ST
Typical Dist. (km)
2
20
50
90
Dimension Drawings
Optical Wavelength (nm)
1310
1310
1310
1310
Cable Size Core/Cladding (um)
50 / 125 or 62.5 / 125
8 / 125 or 9 / 125
8 / 125 or 9 / 125
8 / 125 or 9 / 125
TX Power (Min/Max) (dBm)
-9.5 / -4
-9 /-3
-7 / -3
0/5
RX Sensitivity (dBm)
-15.7
-15.5
-2.5
-2.5
RX Saturation (dBm)
-33.5
-32
-37
-39
17
16.5
34.5
41.5
NOTE
Typical Budget
(dB)
All dimensions
are in on
millimeters,
unlessConsult
otherwise
Longer segment
lengths dependent
fiber specifications.
factory stated.
for further details.
65.13
187.96
168.66
116.59
99.06
7.87
Figure
11:dimensions
Overall Dimensions
Overall
All dimensions are in millimeters, unless otherwise stated.
6-port Managed Ethernet Switch With Dual Port Ethernet Over VDSL Uplinks, 128-bit Encryption
RUGGEDCOM RS930L
9
Chapter 5
RUGGEDCOM RS930L
Dimension drawings
Dimension Drawings
Installation Guide
13.64
11.18
83.82
194.06
183.89
101.60
78.74
120.65
Figure 12: Panel and DIN Rail Mount Dimensions
Panel and DIN rail mount dimensions
All dimensions are in millimeters, unless otherwise stated.
20
10
RUGGEDCOM RS930L
6-port Managed Ethernet Switch With Dual Port Ethernet Over VDSL Uplinks, 128-bit Encryption
Order codes
6GK60930AD2 _______ - 0 - _______ - A - ________ - Z _______ + _______
PS1
Mount
MOD
VV1
VV2
Base Unit includes 6 10/100 BaseTX Ethernet Ports
PS1: Power Supply 1
1 = 24 VDC (10-36 VDC)
2 = 48 VDC (36-72 VDC)
3 = 87-264VAC or 88-300VDC
Mount: Mounting Options
A = No mounting option
B = DIN rail mounting
C = Panel mounting
MOD: Manufacturing Modifications
0 = None
1 = Conformal coating
VV1: VDSL Interface
A00 = Standard reach (under 2.5km)
A01 = Long reach (5km) Master / CO
A02 = Long reach (5km) / CPE
VV2: VDSL Interface
B00 = Standard reach (under 2.5km)
B01 = Long reach (5km) Master / CO
B02 = Long reach (5km) / CPE
Power Cables
6GK6000-8BB00-0AA0 – Bare-wire
6GK6000-8BA00-0AA0 – with lugs
Example order codes
6GK6093-0AD21-0BA0-Z A00+B00
24VDC (10-36 VDC), DIN Rail Mounting, Standard reach (under 2.5km) VDSL 1
Interface, Standard reach (under 2.5km) VDSL 2 Interface
6GK6093-0AD22-0CA1-Z A01+B00
48VDC (36-72 VDC), Panel Mounting, Conformal Coating, Long Reach (5km)
Master/CO VDSL 1 Interface, Standard reach (under 2.5km) VDSL 2 Interface
6-port Managed Ethernet Switch With Dual Port Ethernet Over VDSL Uplinks, 128-bit Encryption
RUGGEDCOM RS930L
11
Siemens Industry, Inc.
5300 Triangle Parkway
Norcross, GA 30092
1-800-241-4453
[email protected]
usa.siemens.com/ruggedcom
Subject to change without prior notice.
All rights reserved.
©2015 Siemens Industry, Inc.
The information provided in this brochure contains descriptions or
characteristics of performance which in case of actual use do not
always apply as described or which may change as a result of
further development of the products. An obligation to provide
the respective characteristics shall only exist if expressly agreed in
the terms of contract. Availability and technical specifications are
subject to change without notice.
All product designations may be trademarks or product names
of Siemens AG or supplier companies whose use by third parties
for their own purposes could violate the rights of the owners.