Product Overview RUGGEDCOM RS950G Managed PRP Redundancy Box The RUGGEDCOM RS950G from Siemens is a platform to demonstrate RUGGEDCOM’s on-going implementation of network redundancy as defined in the standard IEC 62439-3. The RS950G is a rugged fiber and copper universally deployable IEC 62439-4 Redundancy Box (RedBox), that supports both High Availability Seamless Redundancy (HSR) and Parallel Redundancy Protocol (PRP), and extends the life of legacy IEDs by connecting them to HSR/PRP networks. Designed to operate reliably in harsh environments the RS950G provides a high level of immunity to electromagnetic interference and heavy electrical surges typical of environments found in electric utility substations, curb side traffic control cabinets, and factory floors. An operating temperature range of -40°C to +85°C coupled with hazardous location compliance (Class 1 Division 2), optional conformal coating and a galvanized steel enclosure allows the RS950G to be placed in almost any location. The RS950G provides the ultimate in network reliability and zero failover time from any network fault. This is achieved by simultaneously transmitting duplicate packets on independent routes through the network to provide complete path redundancy at the data link layer. The RS950G supports full HSR RedBox functionality as described in IEC62439-3, including generation of HSR supervision frames on behalf of Singly Attached Nodes (SANs). In PRP networks the receiving nodes eliminate redundant packets resulting in a truly seamless failover mechanism that is not compromised by failures. All RUGGEDCOM products are backed by a five year warranty and unsurpassed technical support. PRP and HSR are two mechanisms defined by the IEC 62439-3 standard to provide hitless network recovery. PRP provides hitless network recovery by replicating information over two physically independent Ethernet networks. The basic principle behind HSR is the replication of frames over both sides of the HRS ring. usa.siemens.com/ruggedcom Features and benefits Reliability Precision Timing ■ IEC 62439-3 PRP ■ Guaranteed behavior under failure conditions ■ High availability network using simultaneous transmission over two Ethernet ports ■ Efficient elimination of duplicated packets at hardware level ■ Zero recovery time from network failures ■ FPGA implementation maximizes PRP performance ■ IEEE 1588 v2 with hardware time stamping on all ports ■ Transparent clock operation Ethernet Ports ■ 3 configurable copper or fiber ports - 2 IEC 62439 Ethernet ports (HSR or PRP) - 1 Access port for standard IEEE 802.3 Ethernet devices ■ SFP pluggable fiber transceiver with 100FX or 1000LX/SX options ■ 3 X 10/100/1000 BaseT copper ports (disabled when SFP present) ■ RS232 Console Port ■ Up to 70km with long-haul optics ■ LED Status Indicators Cyber Security Features ■ Muti-level user passwords ■ SSH/SSL (128-bit encryption) ■ Enable/disable ports, MAC based port security ■ SSL web based management with data encryption ■ RADIUS centralized password management ■ SNMPv3 authentication and 56-bit encryption 2 RUGGEDCOM RS950G Rugged Rated for Reliability in Harsh Environments ■ Immunity to EMI and heavy electrical surges - IEC 62439-3 PRP - Meets IEEE 1613 (electric utility substations) - Exceeds IEC 61850-3 (electric utility substations) ■ -40°C to +85°C operating temperature ■ No moving parts ■ Conformal coated printed circuit boards (optional) Management Tools ■ Web-based, Telnet, CLI management interfaces ■ SNMP v1/v2/v3 (56-bit encryption) ■ Remote monitoring (RMON) ■ Rich set of diagnostics with logging and alarms ■ IEC 62439 MIB Support Universal Power Supply Options ■ Fully integrated power supply (no external adaptors) ■ Popular low-voltage DC ranges: 24VDC (10-36VDC) or 48VDC (36-72VDC) ■ Universal high-voltage range: 88-300VDC or 85-264VAC ■ CSA/UL 60950 safety approved to +85°C ■ Screw connection terminal blocks ensure reliable maintenance free connections Managed PRP Redundancy Box RUGGEDCOM RS950G Power Inputs Dual Ports (Fiber or Copper) 24 VDC (10-36 VDC) 48 VDC (36-72 VDC) 85-264VAC or 88-300VDC Fiber: Pluggable Optics (SFP) LC connectors Copper: 100TX/RJ45 Rugged Construction 20 AWG galvanized steel enclosure Conformal coating (optional) Operating Temperature -40°C to +85°C No fans Managed PRP Redundancy Box Critical Alarm Relay Mounting Options Form-C failsafe contact relay: 1A@30VDC DIN rail Panel mount RUGGEDCOM RS950G 3 Parallel Redundancy Protocol (PRP) Benefits Applications ■ Connects legacy non-PRP devices to high availability IEC 62439 networks ■ Delivers unprecedented reliability, resilience to faults and performance for the most critical applications ■ Allows scalability by supporting multiple network topologies, eg: tree, ring, mesh, etc. ■ Substation automation networks compliant to IEC 61850 ■ Reliable circuit breaker tripping via GOOSE ■ Guaranteed delivery of sampled measured values (SMV) on IEC 61850-9-2 process bus ■ High availability industrial control networks with zero failover time ■ Time-critical and Safety-critical transport systems Sending Node RUGGEDCOM RS950G RUGGEDCOM RS950G RUGGEDCOM RS950G RUGGEDCOM RS950G Receiving Node Network A RUGGEDCOM RS950G Singly Attached Node RUGGEDCOM RS950G Network B RUGGEDCOM RS950G RUGGEDCOM RS950G IED The RS950G can be used in PRP mode. Duplicate packets are generated by the sending node and removed at the receiving node as required. With PRP, singly attached nodes can be part of the network. 4 RUGGEDCOM RS950G Managed PRP Redundancy Box ROS Features Parallel Redundancy Protocol (PRP) The RuggedCom RS950G is compliant with IEC 62439 and PRP. The RS950G generates duplicate packets and transmits them on independent paths on the PRP networks, providing complete redundancy for network or device faults that could interrupt the continued operation. If both paths remain intact and the receiving node receives duplicate packets, the RS950G ensures the duplicate packets are removed and taken out of circulation. The RS950G permits connection of singly attached nodes to the PRP networks. Cyber Security ■ Passwords – Multilevel user passwords secure switch against unauthorized configuration ■ SSH / SSL – Extends capability of password protection to add 128-bit encryption of passwords and data as they cross the network ■ MAC-based port security – Ability to secure ports on a switch so only specific devices / MAC addresses can communicate via that port ■ RADIUS – Authentication service using MD5 hash and providing centralized password management ■ SNMPv3 – Encrypted authentication access security and data encryption (CBC-DES with 56-bit encryption key) ■ Secure Sockets Layer – Web-based management using SSL with data encryption (128-bit encryption key) Loss of Link Management Some intelligent electronic devices (IEDs) have dual fiber optic ports with automatic failover to a backup port should the primary fail. ROS ensures this mechanism works reliably under all failure modes by appropriately disabling link signals when required. ROS also flushes learned MAC addresses to ensure the failover occurs quickly. Port Statistics and RMON (Remote Monitoring) ROS provides continuously updating statistics per port that provide both ingress and egress packet and byte counters as well as detailed error figures. Also provided is full support for the RMON statistics, history, alarms, and event groups. RMON allows for very sophisticated data collection, analysis and detection of traffic patterns. Event Logging and Alarms ROS records all significant events to a non-volatile system log allowing forensic troubleshooting. Events include link failure and recovery, unauthorized access, broadcast storm detection, and self-test diagnostics among others. Alarms provide a snapshot of recent events that have yet to be acknowledged by the network administrator. An external hardware relay is de-energized during the presence of critical alarms allowing an external controller to react if desired. SNMP (Simple Network Management Protocol) HTML Web Browser and Telnet/SSH User Interfaces SNMP provides a standardized method for network management stations to interrogate devices from different vendors. SNMPv3 in particular provides security features such as authentication, privacy with data encryption (CBC-DES with 56-bit encryption key) and access control not present in earlier SNMP versions. ROS also supports numerous standard MIBs (Management Information Base) allowing for easy integration with any network management system (NMS). Configuration via ASCII Text File A feature of SNMP supported by ROS is the ability to generate “traps” upon system events. RUGGEDCOM NMS, the RUGGEDCOM management solution, can record traps from multiple devices providing a powerful network troubleshooting tool. It also provides a graphical visualization of the network and is fully integrated with all RUGGEDCOM products. SNTP (Simple Network Time Protocol) SNTP automatically synchronizes the internal clock of all ROS devices on the network. This allows for correlation of time stamped events for troubleshooting. Managed PRP Redundancy Box ROS provides a simple, intuitive user interface for configuration and monitoring via a standard graphical web browser or via Telnet/SSH. All system parameters include detailed on-line help to make setup a breeze. ROS, presents a common look and feel and standardized configuration process allowing easy migration to other RUGGEDCOM managed products. All configuration parameters are stored in an ASCII formatted text file that can easily be transferred via TFTP, SFTP or Xmodem. The configuration file can be saved for backup purposes and easily manipulated by a text editor. The same text file can be downloaded to the switch at a later date in order to re-configure or restore a previous configuration. Command Line Interface (CLI) A command line interface can be used in conjunction with remote shell to automate data retrieval, configuration updates, and firmware upgrades. A powerful SQL-like capability allows expert users the ability to selectively retrieve or manipulate any parameters the device has to offer. RUGGEDCOM RS950G 5 EMI and Environmental Type Tests IEC 61850-3 EMI Type Tests Test Description IEC 61000-4-2 ESD IEC 61000-4-3 Radiated RFI IEC 61000-4-4 Burst (fast transient) IEC 61000-4-5 Surge IEC 61000-4-6 Induced (conducted) RFI IEC 61000-4-8 Magnetic field IEC 61000-4-29 Test Levels Severity Levels Enclosure contact Enclosure air Enclosure ports Signal ports D.C. power ports A.C. power ports Earth ground ports 3 +/- 8kV +/- 15kV 20 V/m +/- 4kV @ 2.5kHz +/- 4kV +/- 4kV +/- 4kV 4 4 x x 4 4 4 Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line 4 D.C. power ports A.C. power ports Signal ports D.C power ports A.C. power ports Earth ground ports 3 Signal ports D.C. power ports A.C. power ports Signal ports D.C. power ports D.C. power ports Signal ports D.C. power ports A.C. power ports Signal ports D.C. Power ports A.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line +/- 4kV line-to-earth, +/- 2kV line-to-line 10V 10V 10V 10V 40 A/m continuous, 1000 A/m for 1 s 1000 A/m for 1 s 30% for 0.1s, 60% for 0.1s, 100% for 0.05s 30% for 1 period, 60% for 50 periods 100% for 5 periods, 100% for 50 periods 2 2.5kV common, 1kV diff. mode@1MHz 2.5kV common, 1kV diff. mode@1MHz 2.5kV common, 1kV diff. mode@1MHz 30V Continuous, 300V for 1s 30V Continuous, 300V for 1s 10% 2kVac (Fail-safe relay output) 1.5V DC 2kVac 5kV (Fail-safe relay output) 5kV 5kV 3 4 3 3 3 3 N/A N/A N/A N/A N/A 3 3 3 4 4 3 N/A N/A N/A N/A N/A N/A Enclosure contact Enclosure air Enclosure ports Test Levels +/- 8kV +/-15kV 35 V/m Severity Levels N/A N/A N/A Signal ports D.C. power ports A.C. power ports Earth ground ports 3 Signal ports D.C. power ports A.C. power ports Signal ports D.C. power ports A.C. power ports Signal ports D.C. power ports A.C. power ports +/- 4kV @ 2.5kHz +/- 4kV +/- 4kV +/- 4kV 2.5kV common mode@1MHz 2.5kV common, 1kV diff. mode@1MHz 2.5kV common, 1kV diff. mode@1MHz 5kV (Fail-safe relay output) 5kV 5kV 2kVac 1.5kVac 2kVac N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Enclosure ports D.C. power ports Voltage dips and interrupts IEC 61000-4-11 IEC 61000-4-12 Damped oscillatory IEC 61000-4-16 Mains frequency voltage IEC 61000-4-17 Ripple on D.C. power supply IEC 60255-5 Dielectric strength IEC 60255-5 H.V. Impulse A.C. power ports IEEE 1613 (C37.90.x) EMI immunity Type Tests Test Description IEEE C37.90.3 ESD IEEE C37.90.2 Radiated RFI IEEE C37.90.1 Fast transient IEEE C37.90.1 Oscillatory IEEE C37.90 H.V. impulse IEEE C37.90. Dielectric strength Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068-2-1 Cold temperature Test Ad -40°C, 16 hours N/A IEC 60068-2-2 Dry heat Test Bd +85°C, 16 hours N/A IEC 60068-2-30 Humidity (damp heat, cyclic) Test Db 95% (non-condensing), 55°C , 6 cycles N/A IEC 60255-21-1 Vibration Test Fc 2g @ (10 - 150) Hz Class 2 2 IEC 60255-21-2 Shock Test Ea 30g @ 11mS Class 2 2 1 RUGGEDCOM specified severity levels. 2 Class 2 refers to “Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are very high, (e.g. shipboard application and for severe transportation conditions”). 3 Only applicable to functional earth connections separated from the safety earth connection. 6 RUGGEDCOM RS950G Managed PRP Redundancy Box Technical Specifications Interfaces ■ Two IEC 62439 PRP Ethernet ports ■ One access port for standard IEEE 802.3 Ethernet devices ■ All Ethernet ports support copper or fiber media - SFP pluggable fiber transceiver with 100FX - 100TX (disabled when SFP present) ■ RS232 Console Port ■ LED Status Indicators Power ■ Dual DC inputs ■ Power Consumption: 10W Max ■ 24VDC: 10-36 VDC, 1.2A ■ 48VDC: 36-72 VDC, 0.6A ■ HI Voltage AC/DC: 88-300VDC or 85-264VAC Network Management ■ HTTPS graphical web-based ■ Telnet, VT100 ■ Command Line Interface (CLI) ■ SSH/SFTP (128-bit encryption) - SNMP v1, v2c, v3 (56-bit encryption) - Authentication and Accounting - TACACS+ - RADIUS client Warranty ■ 5 Years – Applicable to design and manufacturing related product defects. EMI Immunity and Environmental Compliance Critical Alarm Relay ■IEC 61000-6-2 Industrial (Generic) ■IEC 61800-3 Industrial (Variable Speed Drive Systems) ■ IEC 61850-3 Electric Utility Substations ■ IEEE 1613 Electric Utility Substations ■ Hazardous Locations: Class 1, Division 2 Environmental ■ 802.3u-100BaseTX, 100BaseFX ■ Form-C contact relay: - Max Voltage 250VAC,125VDC - Max Current 2A@250VAC, 2A@30VDC ■ -40 to +85C (operating and storage) (no fans) ■ 5 to 95% relative humidity (non-condensing) IEEE Compliance IETF RFC Compliance ■ MAC addresses: 1024 ■ Frame buffer memory: 512k bits ■RFC768-UDP ■ RFC783-TFTP ■ RFC791-IP ■RFC792-ICMP ■RFC793-TCP ■ RFC826-ARP ■ RFC854-Telnet ■RFC894-IP over Ethernet ■RFC2865-RADIUS ■RFC1519-CIDR ■RFC1541-DHCP (client) ■RFC2030-SNTP ■RFC2068-HTTP Regulatory Approvals IETF SNMP MIBS Physical Dimensions ■ Height: 7.4” (188mm) ■ Width: 2.6” (66mm) ■ Depth: 5.0” (127mm) ■ Weight: 1.22kg ■ Ingress Protection: IP40 (1mm objects) ■ Enclosure: 20 AWG galvanized steel enclosure ■ Mounting: DIN rail or panel mounted Switch Properties ■ ISO: Designed and manufactured using an ISO9001: 2000 certified quality program ■ CE marking ■ Emissions: FCC Part 15 (Class A), EN55022 (CISPR22 Class A) ■ Safety: cCSAus (Compliant with CSA C22.2 No. 60950, UL 60950, EN60950) ■ Laser eye safety (FDA/CDRH): Complies with 21 CFR Chapter 1, Subchapter J Managed PRP Redundancy Box ■ RFC1493-BRIDGE-MIB ■RFC1907-SNMPv2-MIB ■RFC2012-TCP-MIB ■RFC2013-UDP-MIB ■RFC2578-SNMPv2-SMI ■RFC2579-SNMPv2-TC ■RFC2863-IF-MIB ■IANAifType-MIB RUGGEDCOM RS950G 7 Fiber Specifications and Dimension Drawings Fiber Optical RUGGEDCOM RS950G Specifications Chapter 5 Installation Guide Parameter Dimension Drawings Fiber Port Type Mode Multimode Singlemode Singlemode Singlemode Connector LC, LC-SFP SC, LC, LC-SFP SC, LC, LC-SFP LC-SFP Dimension Drawings Typical Dist. (km) 500m 10km 25km 70km Optical Wavelength (nm) 850 1310 1310 1550 Cable Size Core/Cladding (um) 50 / 125 or 62.5 / 125 8 / 125 or 9 / 125 8 / 125 or 9 / 125 8 / 125 or 9 / 125 TX Power (Min/Max) (dBm) -9.5 / -4 -9 /-3 -7 / -3 0/5 RX Sensitivity (dBm) -20 -22 -26 -23 0- -3 NOTE RX Saturation (dBm) All dimensions are in millimeters, unless otherwise stated. 14 17 Typical Budget (dB) 0.31 0 25 4.59 6.64 7.40 2.56 -3 19 Figure 16:dimensions Overall Dimensions Overall All dimensions are in millimeters, unless otherwise stated. 8 RUGGEDCOM RS950G Managed PRP Redundancy Box Chapter 5 RUGGEDCOM RS950G Dimension Drawings Installation Guide Dimension Drawings 0.44 7.24 0.54 3.30 7.64 3.10 5.39 4.59 4.00 3.90 4.75 Figure 17: Panel and Din Rail Mount Dimensions Panel and DIN rail mount dimensions All dimensions are in millimeters, unless otherwise stated. 22 Managed PRP Redundancy Box RUGGEDCOM RS950G 9 Order Codes 6GK60950GS2 - ______ - 0 - ________ - A - ________ - Z ______ + ______ + _______ PS1 Mount MOD P1 P2 Local PS1: Power Supply 1 P2: HSR/PRP A: 1 = 24 VDC (10-36 VDC) 2 = 48 VDC (36-72 VDC) 3 = 88-300VDC or 85-264VAC B00 = RJ45, No SFP Installed B01 = 1 x 1000SX SFP - Multimode, 850nm, LC, 500m B02 = 1 x 1000LX SFP - Singlemode, 1310nm, LC, 10km B03 = 1 x 1000LX SFP - Singlemode, 1310nm, LC, 25km B04 = 1 x 1000LX SFP - Singlemode, 1550nm, LC, 70km B05 = 1 x 100FX SFP - Multimode, 1310nm, LC, 2km B06 = 1 x 100FX SFP - Singlemode, 1310nm, LC, 20km Mount: Mounting Options A = No Mounting Option B = DIN Rail Mounting C = Panel Mounting MOD: Manufacturing Modifications 0 = None 1 = Conformal coating P1: HSR/PRP B A00 = RJ45, No SFP Installed A01 = 1 x 1000SX SFP - Multimode, 850nm, LC, 500m A02 = 1 x 1000LX SFP - Singlemode, 1310nm, LC, 10km A03 = 1 x 1000LX SFP - Singlemode, 1310nm, LC, 25km A04 = 1 x 1000LX SFP - Singlemode, 1550nm, LC, 70km A05 = 1 x 100FX SFP - Multimode, 1310nm, LC, 2km A06 = 1 x 100FX SFP - Singlemode, 1310nm, LC, 20km Local: C00 = RJ45, No SFP Installed C01 = 1 x 1000SX SFP - Multimode, 850nm, LC, 500m C02 = 1 x 1000LX SFP - Singlemode, 1310nm, LC, 10km C03 = 1 x 1000LX SFP - Singlemode, 1310nm, LC, 25km C04 = 1 x 1000LX SFP - Singlemode, 1550nm, LC, 70km C05 = 1 x 100FX SFP - Multimode, 1310nm, LC, 2km C06 = 1 x 100FX SFP - Singlemode, 1310nm, LC, 20km Example Order Codes 6GK6095-0GS21-0BA0-Z A00+B00+C00 24 VDC (10-36 VDC), DIN Rail Mounting, RJ45, No SFP Installed in HSR/PRP A, B, and Local 6GK6095-0GS21-0CA1-Z A03+B01+C00 24 VDC (10-36 VDC), Panel Mounting, Conformal Coating, 1 x 1000LX SFP Singlemode, 1310nm, LC, 25km HSR/PRP B, 1 x 1000SX SFP - Multimode, 850nm, LC, 500m HSR/PRP A, RJ45, No SFP Installed Local 10 RUGGEDCOM RS950G Managed PRP Redundancy Box Siemens Industry, Inc. 5300 Triangle Parkway Norcross, GA 30092 1-800-241-4453 [email protected] usa.siemens.com/ruggedcom Subject to change without prior notice. All rights reserved. ©2015 Siemens Industry, Inc. The information provided in this brochure contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.