NCV7513A FLEXMOSt Hex Low-Side MOSFET Pre-Driver The NCV7513A programmable six channel low−side MOSFET pre−driver is one of a family of FLEXMOSTM automotive grade products for driving logic−level MOSFETs. The product is controllable by a combination of serial SPI and parallel inputs. It features programmable fault management modes and allows power−limiting PWM operation with programmable refresh time. The device offers 3.3 V/5.0 V compatible inputs and the serial output driver can be powered from either 3.3 V or 5.0 V. Power−on reset provides controlled powerup and two enable inputs allow all outputs to be simultaneously disabled. Each channel independently monitors its external MOSFET’s drain voltage for fault conditions. Shorted load fault detection thresholds are fully programmable using an externally programmed reference voltage and a combination of four discrete internal ratio values. The ratio values are SPI selectable and allow different detection thresholds for each group of three output channels. Fault information for each channel is 2−bit encoded by fault type and is available through SPI communication. Fault recovery operation for each channel is programmable and may be selected for latch−off or automatic retry. The FLEXMOS family of products offers application scalability through choice of external MOSFETs. Features • • • • • • • • • • • 16−Bit SPI with Frame Error Detection 3.3 V/5.0 V Compatible Parallel and Serial Control Inputs 3.3 V/5.0 V Compatible Serial Output Driver Two Enable Inputs Open−Drain Fault and Status Flags Programmable − Shorted Load Fault Detection Thresholds − Fault Recovery Mode − Fault Retry Timer − Flag Masking Load Diagnostics with Latched Unique Fault Type Data − Shorted Load − Open Load − Short to GND AEC Qualified PPAP Capable NCV Prefix for Automotive and Other Applications Requiring Site and Change Controls These are Pb−Free Devices* http://onsemi.com MARKING DIAGRAM 32 LEAD LQFP FT SUFFIX CASE 873A A WL YY WW G NCV7513A AWLYYWWG = Assembly Location = Wafer Lot = Year = Work Week = Pb−Free Package ORDERING INFORMATION Device Package Shipping† NCV7513AFTG LQFP (Pb−Free) 250 Units/Tray NCV7513AFTR2G LQFP 2000 Tape & Reel (Pb−Free) †For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging Specification Brochure, BRD8011/D. Benefits • Scalable to Load by Choice of External MOSFET *For additional information on our Pb−Free strategy and soldering details, please download the ON Semiconductor Soldering and Mounting Techniques Reference Manual, SOLDERRM/D. © Semiconductor Components Industries, LLC, 2009 March, 2009 − Rev. 1 1 Publication Order Number: NCV7513A/D NCV7513A IN5 IN4 IN3 IN2 IN1 IN0 ENA2 VCC2 NCV7513A CHANNEL 0 Hex MOSFET Pre−Driver POWER ON RESET & BIAS VCC1 DRN0 FAULT DETECT VSS POR VCC2 DRIVER ENA1 GATE SELECT GAT0 VSS FLAG MASK ENA ENA VCC2 DRN 1 2 REF DISABLE DISABLE MODE REFRESH/REF CSB PARALLEL SERIAL IREF 6 ENA ENA VCC2 DRN 1 2 REF DISABLE PARALLEL SERIAL VCC SCLK POR CSB SCLK SI SI CHANNEL 1 CHANNEL 2 IREF SPI ENA ENA VCC2 DRN 1 2 REF DISABLE 16 BIT VDD VSS VSS CHANNEL 3 PARALLEL SERIAL SO DRIVER IREF SO ENA ENA VCC2 1 2 REF DISABLE PARALLEL SERIAL DRN VSS 12 FAULT BITS 2 GND + OA − ENA ENA VCC2 DRN 1 2 REF DISABLE FAULT LOGIC & REFRESH TIMER ENA1 4 FLTREF CHANNEL 4 IREF FLTB VSS CHANNEL 5 PARALLEL SERIAL IREF CLOCK FAULT REFERENCE GENERATOR VSS DRN 0:5 CH 0−2 MASK 0:5 CH 3−5 POR Figure 1. Block Diagram http://onsemi.com 2 ENA 1 VSS DRN1 GAT1 DRN2 GAT2 DRN3 GAT3 DRN4 GAT4 DRN5 GAT5 VSS DRAIN FEEDBACK MONITOR STAB M +5V 14W UNCLAMPED LOAD VLOAD 14W 28W 28W 5W NCV7513A RFILT CB1 +5V OR +3.3V RX1 POWER−ON RESET VCC1 VCC2 FLTREF DRN0 ENA1 GAT0 ENA2 DRN1 IN0 GAT1 IN1 DRN2 RD0 NID9N05CL IN2 IN3 SPI RD1 NID9N05CL IN4 IN5 RD2 NID9N05CL NCV7513A HOST CONTROLLER PARALLEL RX2 RST GAT2 DRN3 RD3 CB2 NID9N05CL GAT3 DRN4 RD4 NID9N05CL IRQ FLTB GAT4 I/O CSB DRN5 SCLK GAT5 RD5 NID9N05CL RFPU RSPU SI VDD STAB SO GND VSS Figure 2. Application Diagram http://onsemi.com 3 NCV7513A PIN FUNCTION DESCRIPTION Symbol FLTREF Description Analog Fault Detect Threshold: 5.0 V Compliant DRN0 – DRN5 Analog Drain Feedback: Internally Clamped GAT0 – GAT5 Analog Gate Drive: 5.0 V Compliant ENA1, ENA2 Digital Master Enable Inputs: 3.3 V/5.0 V (TTL) Compatible Digital Parallel Input: 3.3 V/5.0 V (TTL) Compatible Digital Serial Data Output: 3.3 V/5.0 V Compliant STAB Digital Open−Drain Output: 3.3 V/5.0 V Compliant FLTB Digital Open−Drain Output: 3.3 V/5.0 V Compliant VCC1 Power Supply − Low Power Path GND Power Return − Low Power Path – Device Substrate VCC2 Power Supply − Gate Drivers VDD Power Supply − Serial Output Driver VSS Power Return – VCC2, VDD, Drain Clamps DRN5 SO GAT4 Digital Serial Data Input: 3.3 V/5.0 V (TTL) Compatible DRN4 SI GAT3 Digital Shift Clock Input: 3.3 V/5.0 V (TTL) Compatible DRN3 SCLK GAT2 Digital Chip Select Input: 3.3 V/5.0 V (TTL) Compatible DRN2 CSB GAT5 IN0 – IN5 24 23 22 21 20 19 18 17 GAT1 25 16 VSS DRN1 26 15 STAB GAT0 27 14 VDD DRN0 28 13 SO VCC2 29 12 SI VCC1 30 11 SCLK FLTREF 31 10 CSB GND 32 9 FLTB 1 2 3 4 5 6 7 8 IN0 IN1 IN2 IN3 IN4 IN5 ENA2 ENA1 NCV7513A Figure 3. 32 Pin LQFP Pinout (Top View) http://onsemi.com 4 NCV7513A MAXIMUM RATINGS (Voltages are with respect to device substrate.) Rating Value Unit −0.3 to 6.5 V Difference Between VCC1 and VCC2 "0.3 V Difference Between GND (Substrate) and VSS "0.3 V Output Voltage (Any Output) −0.3 to 6.5 V Drain Feedback Clamp Voltage (Note 1) −0.3 to 40 V Drain Feedback Clamp Current (Note 1) 10 mA Input Voltage (Any Input) −0.3 to 6.5 V Junction Temperature, TJ −40 to 150 °C Storage Temperature, TSTG −65 to 150 °C Peak Reflow Soldering Temperature: Lead−Free 60 to 150 seconds at 217°C (Note 2) 260 peak °C DC Supply (VCC1, VCC2, VDD) Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect device reliability. ATTRIBUTES Characteristic Value ESD Capability Human Body Model Machine Model w " 2.0 kV w " 200 V Moisture Sensitivity (Note 2) MSL3 Package Thermal Resistance (Note 3) Junction–to–Ambient, RqJA Junction–to–Pin, RYJL 86.0 °C/W 58.5 °C/W 1. An external series resistor must be connected between the MOSFET drain and the feedback input in the application. Total clamp power dissipation is limited by the maximum junction temperature, the application environment temperature, and the package thermal resistances. 2. For additional information, see or download ON Semiconductor’s Soldering and Mounting Techniques Reference Manual, SOLDERRM/D, and Application Note AND8003/D. 3. Values represent still air steady−state thermal performance on a 4 layer (42 x 42 x 1.5 mm) PCB with 1 oz. copper on an FR4 substrate, using a minimum width signal trace pattern (384 mm2 trace area). RECOMMENDED OPERATING CONDITIONS Symbol Parameter Min Max Unit 4.75 5.25 V VCC1 − 0.3 VCC1 + 0.3 V Serial Output Driver Power Supply Voltage 3.0 VCC1 V VIN High Logic High Input Voltage 2.0 VCC1 V VIN Low Logic Low Input Voltage 0 0.8 V −40 125 °C VCC1 Main Power Supply Voltage VCC2 Gate Drivers Power Supply Voltage VDD TA Ambient Still−Air Operating Temperature http://onsemi.com 5 NCV7513A ELECTRICAL CHARACTERISTICS (4.75 VvVCCXv5.25 V, VDD = VCCX, −40°CvTJv125°C, unless otherwise specified.) (Note 4) Characteristic Symbol Conditions Min Typ Max Unit ENAX = 0 ENA1 = ENA2 = VCC1, VDRNX = 0 V, GATX drivers off ENA1 = ENA2 = VCC1, GATX drivers on – – 2.80 3.10 5.0 5.0 mA – 2.80 5.0 3.65 4.20 4.60 V 0.150 0.385 – V 2.0 – – V VCC1 Supply Operating Current – VCC1 = 5.25 V, VFLTREF = 1.0 V Power−On Reset Threshold VCC1 Rising Power−On Reset Hysteresis − Digital I/O VIN High ENAX, INX, SI, SCLK, CSB VIN Low ENAX, INX, SI, SCLK, CSB – – 0.8 V VIN Hysteresis ENAX, INX, SI, SCLK, CSB 100 330 500 mV Input Pullup Current CSB VIN = 0 V −25 −10 – mA Input Pulldown Current ENA2, INX, SI, SCLK, VIN = VCC1 – 10 25 mA Input Pulldown Resistance ENA1 SO Low Voltage VDD = 3.3 V, ISINK = 5.0 mA SO High Voltage VDD = 3.3 V, ISOURCE = 5.0 mA SO Output Resistance Output High or Low SO Tri−State Leakage Current CSB = 3.3 V STAB Low Voltage STAB Leakage Current 100 150 200 kW – 0.11 0.25 V VDD − 0.25 VDD − 0.11 – V – 22 – W −10 – 10 mA STAB Active, ISTAB = 1.25 mA – 0.1 0.25 V VSTAB = VCC1 – – 10 mA FLTB Low Voltage FLTB Active, IFLTB = 1.25 mA – 0.1 0.25 V FLTB Leakage Current VFLTB = VCC1 – – 10 mA FLTREF Input Current VFLTREF = 0 V −1.0 – – mA FLTREF Input Linear Range (Note 5) 0 – VCC1 − 2.0 V (Note 5) 30 – – dB IDRNX = 10 mA IDRNX = ICL(MAX) = 10 mA 27 – 32 33.6 – 37 V Register 2: R1 = 0, R0 = 0 or R4 = 0, R3 = 0 20 25 30 % VFLTREF Register 2: R1 = 0, R0 = 1 or R4 = 0, R3 = 1 45 50 55 % VFLTREF Register 2: R1 = 1, R0 = 0 or R4 = 1, R3 = 0 70 75 80 % VFLTREF Register 2: R1 = 1, R0 = 1 or R4 = 1, R3 = 1 95 100 105 % VFLTREF VCC1 = VCC2 = VDD = 5.0 V, ENAX = INX = 0 V, VDRNX = VCL(MIN) VCC1 = VCC2 = VDD = 0 V, ENAX = INX = 0 V, VDRNX = VCL(MIN) −1.0 – 1.0 mA Fault Detection – GATX ON FLTREF Op−amp VCC1 PSRR DRNX Clamp Voltage DRNX Shorted Load Threshold GATX Output High VFLTREF = 1.0 V DRNX Input Leakage Current VCL 4. Designed to meet these characteristics over the stated voltage and temperature recommended operating ranges, though may not be 100% parametrically tested in production. 5. Guaranteed by design. http://onsemi.com 6 NCV7513A ELECTRICAL CHARACTERISTICS (continued) (4.75 VvVCCXv5.25 V, VDD = VCCX, −40°CvTJv125°C, unless otherwise specified.) (Note 6) Characteristic Symbol Conditions Min Typ Max Unit Fault Detection – GATX OFF DRNX Diagnostic Current DRNX Fault Threshold Voltage DRNX Off State Bias Voltage ISG Short to GND Detection, VDRNX = 0.30 VCC1 −27 −20 −10 mA IOL Open Load Detection, VDRNX = 0.75 VCC1 30 60 80 mA VSG Short to GND Detection 27 30 33 %VCC1 VOL Open Load Detection 72 75 78 %VCC1 – 50 – %VCC1 1.0 1.80 2.5 kW −5.25 – −1.9 mA 1.9 – 5.25 mA – – 1.0 – – 1.0 – – 1.40 ms – – 1.40 ms VCTR − Gate Driver Outputs GATX Output Resistance Output High or Low GATX High Output Current VGATX = 0 V GATX Low Output Current VGATX = VCC2 Turn−On Propagation Delay tP(ON) Turn−Off Propagation Delay tP(OFF) INX to GATX (Figure 4) CSB to GATX (Figure 5) INX to GATX (Figure 4) CSB to GATX (Figure 5) Output Rise Time tR 20% to 80% of VCC2, ms ms CLOAD = 400 pF (Figure 4, Note 5) Output Fall Time tF 80% to 20% of VCC2, CLOAD = 400 pF (Figure 4, Note 5) Fault Timers Channel Fault Blanking Timer tBL(ON) VDRNX = 5.0 V; INX rising to FLTB falling (Figure 6) 30 45 60 ms tBL(OFF) VDRNX = 0 V; INX falling to FLTB falling (Figure 6) 90 120 150 ms Channel Fault Filter Timer tFF Figure 7 7.0 12 17 ms Global Fault Refresh Timer (Auto−retry Mode) tFR Register 2: Bit R2 = 0 or R5 = 0 7.5 10 12.5 ms Register 2: Bit R2 = 1 or R5 = 1 30 40 50 ms ENA1 = 1 – 500 – kHz 3.0 3.3 3.6 V 4.5 5.0 5.5 V – 250 – ns Timer Clock Serial Peripheral Interface (Figure 9) Vccx = 5.0 V, VDD = 3.3 V, FSCLK = 4.0 MHz, CLOAD = 200 pF SO Supply Voltage VDD 3.3 V Interface 5.0 V Interface SCLK Clock Period − Maximum Input Capacitance Sl, SCLK (Note 7) – – 12 pF SCLK High Time SCLK = 2.0 V to 2.0 V 125 – – ns SCLK Low Time SCLK = 0.8 V to 0.8 V 125 – – ns Sl Setup Time Sl = 0.8 V/2.0 V to SCLK = 2.0 V (Note 7) 25 – – ns Sl Hold Time SCLK = 2.0 V to Sl = 0.8 V/2.0 V (Note 7) 25 – – ns 6. Designed to meet these characteristics over the stated voltage and temperature recommended operating ranges, though may not be 100% parametrically tested in production. 7. Guaranteed by design. http://onsemi.com 7 NCV7513A ELECTRICAL CHARACTERISTICS (continued) (4.75 VvVCCXv5.25 V, VDD = VCCX, −40°CvTJv125°C, unless otherwise specified.) (Note 8) Characteristic Symbol Conditions Min Typ Max Unit Serial Peripheral Interface (continued) (Figure 9) Vccx = 5.0 V, VDD = 3.3 V, FSCLK = 4.0 MHz, CLOAD = 200 pF SO Rise Time (20% VSO to 80% VDD) CLOAD = 200 pF (Note 9) – 25 50 ns SO Fall Time (80% VSO to 20% VDD) CLOAD = 200 pF (Note 9) – – 50 ns CSB Setup Time CSB = 0.8 V to SCLK = 2.0 V (Note 9) 60 – – ns CSB Hold Time SCLK = 0.8 V to CSB = 2.0 V (Note 9) 75 – – ns CSB to SO Time CSB = 0.8 V to SO Data Valid (Note 9) – 65 125 ns SO Delay Time SCLK = 0.8 V to SO Data Valid (Note 9) – 65 125 ns Transfer Delay Time CSB Rising Edge to Next Falling Edge (Note 9) 1.0 – – ms 8. Designed to meet these characteristics over the stated voltage and temperature recommended operating ranges, though may not be 100% parametrically tested in production. 9. Guaranteed by design. http://onsemi.com 8 NCV7513A INX 50% tP(OFF) GAT X tR 80% 50% 20% tP(ON) Figure 4. Gate Driver Timing Diagram – Parallel Input CSB 50% GX tP(OFF) GAT X 50% tP(ON) Figure 5. Gate Driver Timing Diagram – Serial Input DRNX INX 50% tBL(ON) FLTB tBL(OFF) 50% 50% Figure 6. Blanking Timing Diagram http://onsemi.com 9 tF NCV7513A OPEN LOAD THRESHOLD SHORTED LOAD THRESHOLD DRNX INX tFF FLTB tFF 50% 50% Figure 7. Filter Timing Diagram GAT X tBL(ON) tFR tFF DRNX tFR tBL(ON) tFR SHORTED LOAD THRESHOLD (FLTREF) INX Figure 8. Fault Refresh Timing Diagram CSB SETUP TRANSFER DELAY CSB SI SETUP SCLK CSB HOLD 1 16 SI HOLD SI MSB IN SO DELAY CSB to SO VALID SO LSB IN BITS 14...1 MSB OUT SO RISE,FALL BITS 14...1 LSB OUT Note: Not defined but usually MSB of data just received. Figure 9. SPI Timing Diagram http://onsemi.com 10 SEE NOTE 80% VDD 20% VDD NCV7513A DETAILED OPERATING DESCRIPTION General The NCV7513A is a six channel general purpose low−side pre−driver for controlling and protecting N−type logic level MOSFETs. While specifically designed for driving MOSFETs with resistive, inductive or lamp loads in automotive applications, the device is also suitable for industrial and commercial applications. Programmable fault detection and protection modes allow the NCV7513A to accommodate a wide range of external MOSFETs and loads, providing the user with flexible application solutions. Separate power supply pins are provided for low and high current paths to improve analog accuracy and digital signal integrity. ON Semiconductor’s SMARTDISCRETES TM clamp MOSFETs, such as the NID9N05CL, are recommended when driving unclamped inductive loads. The active−low CSB chip select input has a pullup current source. The SI and SCLK inputs have pulldown current sources. The recommended idle state for SCLK is low. The tri−state SO line driver can be supplied with either 3.3 or 5.0 V and is powered via the device’s VDD and VSS pins. The NCV7513A employs frame error detection that requires integer multiples of 16 SCLK cycles during each CSB high−low−high cycle (valid communication frame.) A frame error does not affect the flags. The CSB input controls SPI data transfer and initializes the selected device’s frame error and fault reporting logic. The host initiates communication when a selected device’s CSB pin goes low. Output (fault) data is simultaneously sent MSB first from the SO pin while input (command) data is received MSB first at the SI pin under synchronous control of the master’s SCLK signal while CSB is held low (Figure 10). Fault data changes on the falling edge of SCLK and is guaranteed valid before the next rising edge of SCLK. Command data received must be valid before the rising edge of SCLK. When CSB goes low, frame error detection is initialized, latched fault data is transferred to the SPI, and the FLTB flag is disabled and reset if previously set. Data for faults detected while CSB is low are ignored but will be captured if still present after CSB goes high. If a valid frame has been received when CSB goes high, the last multiple of 16 bits received is decoded into command data, and FLTB is re−enabled. Latched (previous) fault data is cleared and current fault data is captured. The FLTB flag will be set if a fault is detected. If a frame error is detected when CSB goes high, new command data is ignored, and previous fault data remains latched and available for retrieval during the next valid frame. The FLTB flag will be set if a fault (not a frame error) is detected. Power Up/Down Control The NCV7513A’s powerup/down control prevents spurious output operation by monitoring the VCC1 power supply. An internal Power−On Reset (POR) circuit causes all GATX outputs to be held low until sufficient voltage is available to allow proper control of the device. All internal registers are initialized to their default states, fault data is cleared, and the open−drain fault (FLTB) and status (STAB) flags are disabled. When VCC1 exceeds the POR threshold, outputs and flags are enabled and the device is ready to accept input data. When VCC1 falls below the POR threshold during power down, flags are reset and disabled and all GATX outputs are driven and held low until VCC1 falls below about 0.7 V. SPI Communication The NCV7513A is a 16−bit SPI slave device. SPI communication between the host and the NCV7513A may either be parallel via individual CSB addressing or daisy−chained through other devices using a compatible SPI protocol. CSB MSB SCLK SO 1 2 3 14 15 16 X B15 B14 B13 B12 − B3 B2 B1 B0 Z SI LSB 4 − 13 B15 B14 B13 B12 − B3 B2 B1 B0 Note: X=Don’t Care, Z=Tri−State, UKN=Unknown Data Figure 10. SPI Communication Frame Format http://onsemi.com 11 X UKN Z NCV7513A Serial Data and Register Structure The 16−bit data sent by the NCV7513A is always the encoded 12−bit fault information, with the upper 4 bits forced to zero. The 16−bit data received is decoded into a 4−bit address and a 6−bit data word (see Figure 11). The upper four bits, beginning with the received MSB, are fully decoded to address one of four programmable registers and the lower six bits are decoded into data for the addressed register. Bit B15 must always be set to zero. The valid register addresses are shown in Table 1. Each register is next described in detail. MSB LSB B15 B14 B13 B12 B11 B10 0 0 0 0 B9 CH5 B8 B7 CH4 B6 CH3 B5 B4 CH2 B3 B2 CH1 B1 B0 CH0 CHANNEL FAULT OUTPUT DATA REGISTER SELECT COMMAND INPUT DATA MSB LSB B15 B14 B13 B12 B11 B10 0 A2 A1 A0 X X B9 B8 B7 B6 B5 B4 B3 B2 B1 B0 X X X X D5 D4 D3 D2 D1 D0 Figure 11. SPI Data Format Table 1. Register Address Definitions 4−BIT ADDRESS 6−BIT INPUT DATA B15 A2 A1 A0 D5 D4 D3 D2 0 0 0 0 Gate Select 0 0 0 1 Disable Mode 0 0 1 0 Refresh & Reference 0 0 1 1 Flag Mask 0 1 X X Null D1 D0 16−BIT OUTPUT DATA B15 B14 B13 B12 B11 0 0 0 0 D11 B0 12−bit Fault Data Gate Select – Register 0 Each GATX output is turned on/off by programming its respective GX bit (see Table 2). Setting a bit to 1 causes the selected GATX output to drive its external MOSFET’s gate to VCC2 (ON). Setting a bit to 0 causes the selected GATX output to drive its external MOSFET’s gate to VSS (OFF). Note that the actual state of the output depends on POR, ENAX and shorted load fault states as later defined by Equation 1. At powerup, each bit is set to 0 (all outputs OFF). to 1 causes the selected GATX output to latch−off when a fault is detected. Setting a bit to 0 causes the selected GATX output to auto−retry when a fault is detected. At powerup, each bit is set to 0 (all outputs in auto−retry mode). Table 3. Disable Mode Register A1 A0 D5 D4 D3 D2 D1 D0 0 0 0 G5 G4 G3 G2 G1 G0 A2 A1 A0 D5 D4 D3 D2 D1 D0 0 0 1 M5 M4 M3 M2 M1 M0 0 = AUTO−RETRY 1 = LATCH OFF Table 2. Gate Select Register A2 D0 Refresh and Reference – Register 2 Refresh time (auto−retry mode) and shorted load fault detection references are programmable in two groups of three channels. Refresh time and the fault reference for channels 5−3 is programmed by RX bits 5−3. Refresh time and the fault reference for channels 2−0 is programmed by RX bits 2−0 (see Table 4). At powerup, each bit is set to 0 (VFLT = 25% VFLTREF , tFR = 10 ms). 0 = GATX OFF 1 = GATX ON Disable Mode – Register 1 The disable mode for shorted load faults is controlled by each channel’s respective MX bit (see Table 3). Setting a bit http://onsemi.com 12 NCV7513A Table 4. Refresh and Reference Register A2 A1 A0 D5 D4 D3 D2 D1 D0 0 1 0 R5 R4 R3 R2 R1 R0 CHANNELS 5−3 CHANNELS 2−0 25% VFLTREF X 0 0 X 0 0 50% VFLTREF X 0 1 X 0 1 75% VFLTREF X 1 0 X 1 0 VFLTREF X 1 1 X 1 1 tFR = 10 ms X X X 0 X X tFR = 40 ms X X X 1 X X tFR = 10 ms 0 X X X X X tFR = 40 ms 1 X X X X X Flag Mask – Register 3 The drain feedback from each channel’s DRNX input is combined with the channel’s KX mask bit (Table 5). When KX = 1, a channel’s mask is cleared and its feedback to the FLTB and STAB flags is enabled. At powerup, each bit is set to 0 (all masks set). Gate Driver Control and Enable Each GATX output may be turned on by either its respective parallel INX input or the internal GX (Gate Select) register bit via SPI communication. The device’s common ENAX enable inputs can be used to implement global control functions, such as system reset, overvoltage or input override by a watchdog controller. Each parallel input and the ENA2 input have individual internal pulldown current sources. The ENA1 input has an internal pulldown resistor. Unused parallel inputs should be connected to GND and unused enable inputs should be connected to VCC1. Parallel input is recommended when low frequency (v2.0 kHz) PWM operation of the outputs is desired. ENA2 disables all GATX outputs when brought low. When ENA1 is brought low, all GATX outputs, the timer clock, and the flags are disabled. The fault and gate registers are cleared and the flags are reset. New serial GX data is ignored while ENA1 is low but other registers can be programmed. When both the ENA1 and ENA2 inputs are high, the outputs will reflect the current parallel or serial input states. This allows ENA1 to be used to perform a soft reset and ENA2 to be used to disable the GATX outputs during initialization of the NCV7513A. The INX input state and the GX register bit data are logically combined with the internal (active low) power−on reset signal (POR), the ENAX input states, and the shorted load state (SHRTX) to control the corresponding GATX output such that: Table 5. Flag Mask Register A2 A1 A0 D5 D4 D3 D2 D1 D0 0 1 1 K5 K4 K3 K2 K1 K0 0 = MASK SET 1 = MASK CLEAR The STAB flag is influenced when a mask bit changes CLR→SET after one valid SPI frame. FLTB is influenced after two valid SPI frames. This is correct behavior for FLTB since, while a fault persists, the FLTB will be set when CSB goes LO→HI at the end of an SPI frame. The mask instruction is decoded after CSB goes LO→HI so FLTB will only reflect the mask bit change after the next SPI frame. Both FLTB and STAB require only one valid SPI frame when a mask bit changes SET→CLR. Null Register – Register 4 Fault information is always returned when any register is addressed. The null register (Table 6) provides a way to read back fault information without regard to the content of DX. Table 6. Null Register A2 A1 A0 D5 D4 D3 D2 D1 D0 1 X X X X X X X X GATX + POR · ENA1 · ENA2 · SHRTx · (INx ) Gx) (eq. 1) http://onsemi.com 13 NCV7513A On−state faults will initiate MOSFET protection behavior, set the FLTB flag and the respective channel’s DX bits in the device’s fault latches. Off−state faults will simply set the FLTB flag and the channel’s DX bits. Fault types are uniquely encoded in a 2−bit per channel format. Fault information for all channels simultaneously is retrieved by SPI read (Figure 11). Table 8 shows the fault−encoding scheme for channel 0. The remaining channels are identically encoded. The GATX state truth table is given in Table 7. Table 7. Gate Driver Truth Table POR ENA1 ENA2 SHRTX INX GX GATX 0 X X X X X L 1 0 0 X X X L 1 0 1 X X X L 1 1 0 X X X L 1 1 1 1 0 0 L 1 1 1 1 1 X H 1 1 1 1 X 1 H 1 1 1 0 X X L 1 1→0 1 X X →0 →L 1 1 1→0 X X GX →L 1 1 0→1 X 0 GX →GX Table 8. Fault Data Encoding CHANNEL 0 Gate Drivers The non−inverting GATX drivers are symmetrical resistive switches (1.80 kW typ.) to the VCC2 and VSS voltages. While the outputs are designed to provide symmetrical gate drive to an external MOSFET, load current switching symmetry is dependent on the characteristics of the external MOSFET and its load. Figure 12 shows the gate driver block diagram. DX0 DX1 tFR R2 | R 5 MX IN X GX ENA1 ENA2 POR FILTER TIMER ENCODING LOGIC S LATCH OFF / AUTO RE−TRY _ EN R DRNX BLANKING TIMER SHRTX VSS VCC2 DRIVER VSS D1 D0 0 0 NO FAULT 0 1 OPEN LOAD 1 0 SHORT TO GND 1 1 SHORTED LOAD Blanking and Filter Timers Blanking timers are used to allow drain feedback to stabilize after a channel is commanded to change states. Filter timers are used to suppress glitches while a channel is in a stable state. A turn−on blanking timer is started when a channel is commanded on. Drain feedback is sampled after tBL(ON). A turn−off blanking timer is started when a channel is commanded off. Drain feedback is sampled after tBL(OFF). A filter timer is started when a channel is in a stable state and a fault detection threshold associated with that state has been crossed. Drain feedback is sampled after tFF. Blanking timers for all channels are started when both ENA1 and ENA2 go high or when either ENAX goes high while the other is high. The blanking time for each channel depends on the commanded state when ENAX goes high. While each channel has independent blanking and filter timers, the parameters for the tBL(ON), tBL(OFF), and tFF times are the same for all channels. 50 FAULT DETECTION STATUS 1800 GAT X Figure 12. Gate Driver Channel Fault Diagnostics and Behavior Each channel has independent fault diagnostics and employs blanking and filter timers to suppress false faults. An external MOSFET is monitored for fault conditions by connecting its drain to a channel’s DRNX feedback input through an external series resistor. When either ENA1 or ENA2 is low, diagnostics are disabled. When both ENA1 and ENA2 are high, diagnostics are enabled. Shorted load (or short to VLOAD) faults can be detected when a driver is on. Open load or short to GND faults can be detected when a driver is off. Shorted Load Detection An external reference voltage applied to the FLTREF input serves as a common reference for all channels (Figure 13). The FLTREF voltage must be within the range of 0 to VCC1−2.0 V and can be derived via a voltage divider between VCC1 and GND. Shorted load detection thresholds can be programmed via SPI in four 25% increments that are ratiometric to the applied FLTREF voltage. Separate thresholds can be selected for channels 0−2 and for channels 3−5 (Table 4). http://onsemi.com 14 NCV7513A Fault Recovery Refresh Time Refresh time for shorted load faults is SPI programmable to one of two values for channels 0−2 (register bit R2) and for channels 3−5 (register bit R5) via the Refresh and Reference register (Table 4). A global refresh timer with taps at nominally 10 ms and 40 ms is used for auto−retry timing. The first faulted channel triggers the timer and the full refresh period is guaranteed for that channel. An additional faulted channel may initially retry immediately after its turn−on blanking time, but subsequent retries will have the full refresh time period. If all channels in a group (e.g. channels 0−2) become faulted, they will become synchronized to the selected refresh period for that group. If all channels become faulted and are set for the same refresh time, all will become synchronized to the refresh period. A shorted load fault is detected when a channel’s DRNX feedback is greater than its selected fault reference after either the turn−on blanking or the filter has timed out. VCC1 RX1 CHANNELS 0−2 FLTREF 0 − 3V 3 VCC1 2 1 0 + RX2 KELVIN 2X4 DECODER OA − R R1 R0 75% REGISTER 2 BITS R 50% R R4 R3 25% R 3 2 1 0 2X4 DECODER CHANNELS 3−5 Figure 13. Shorted Load Reference Generator Open Load and Short to GND Detection A window comparator with fixed references proportional to VCC1 along with a pair of bias currents is used to detect open load or short to GND faults when a channel is off. Each channel’s DRNX feedback is compared to the references after either the turn−off blanking or the filter has timed out. Figure 14 shows the DRNX bias and fault detection zones. The diagnostics are disabled and the bias currents are turned off when ENAX is low. No fault is detected if the feedback voltage at DRNX is greater than the VOL open load reference. If the feedback is less than the VSG short to GND reference, a short to GND fault is detected. If the feedback is less than VOL and greater than VSG, an open load fault is detected. Shorted Load Fault Recovery Shorted load fault disable mode for each channel is individually SPI programmable via the MX bits in the device’s Disable Mode register (Table 3). When latch−off mode is selected the corresponding GATX output is turned off upon detection of a fault. Fault recovery is initiated by toggling (ON→OFF→ON) the channel’s respective INX parallel input, serial GX bit, or ENA2. When auto−retry mode is selected (default mode) the corresponding GATX output is turned off for the duration of the programmed fault refresh time (tFR) upon detection of a fault. The output is automatically turned back on (if still commanded on) when the refresh time ends. The channel’s DRNX feedback is resampled after the turn−on blanking time. The output will automatically be turned off if a fault is again detected. This behavior will continue for as long as the channel is commanded on and the fault persists. In either mode, a fault may exist at turn−on or may occur some time afterward. To be detected, the fault must exist longer than either tBL(ON) at turn−on or longer than tFF some time after turn−on. The length of time that a MOSFET stays on during a shorted load fault is thus limited to either tBL(ON) or tFF. In auto−retry mode, a persistent shorted load fault will result in a low duty cycle (tFD [ tBL(ON)/tFR) for the affected channel and help prevent thermal failure of the channel’s MOSFET. CAUTION − CONTINUOUS INPUT TOGGLING VIA INX, GX or ENA2 WILL OVERRIDE EITHER DISABLE MODE. Care should be taken to service a shorted load fault quickly when one has been detected. I DRNX Short to GND I OL Open Load No Fault 0 −ISG VSG VCTR VOL VDRNX Figure 14. DRNX Bias and Fault Detection Zones Figure 15 shows the simplified detection circuitry. Bias currents ISG and IOL are applied to a bridge along with bias voltage VCTR (50% VCC1 typ.). http://onsemi.com 15 NCV7513A Status Flag (STAB) The open−drain active−low status flag output can be used to provide a host controller with information about the state of a channel’s DRNx feedback. Feedback from all channels is logically ORed to the flag (Figure 16). The STAB outputs from several devices can be wire−ORed to a common pullup resistor connected to the controller’s 3.3 or 5.0 V VDD supply. When ENA1 is high, the drain feedback from a channel’s DRNx input is compared to the VOL reference without regard to ENA2 or the commanded state of the channel’s driver. The flag is reset and disabled when ENA1 is low or when all mask bits are set. See Table 9 for additional details. The flag is set (low) when the feedback voltage is less than VOL, and the channel’s mask bit (Table 5) is cleared. The flag is reset (hi−Z) when the feedback voltage is greater than VOL, and the channel’s mask bit is cleared. VCC1 I SG A B − CMP1 VLOAD VOL D3 + + CMP2 − D1 1600 DZ1 D4 D2 VSG VCTR + _ I OL (VCL) 50 RLOAD DRNX VX RDX RSG +VOS Figure 15. Short to GND/Open−Load Detection When a channel is off and VLOAD and RLOAD are present, RSG is absent, and VDRNX >> VCTR, bias current IOL is supplied from VLOAD to ground through external resistors RLOAD and RDX, and through the internal 1650 W resistance and bridge diode D2. Bias current ISG is supplied from VCC1 to VCTR through D3. No fault is detected if the feedback voltage (VLOAD minus the total voltage drop caused by ISG and the resistance in the path) is greater than VOL. When either VLOAD or RLOAD and RSG are absent, the bridge will self−bias so that the voltage at DRNX will settle to about VCTR. An open load fault can be detected since the feedback is between VSG and VOL. Short to GND detection can tolerate up to a 1.0 V offset (VOS) between the NCV7513A’s GND and the short. When RSG is present and VDRNX << VCTR, bias current ISG is supplied from VCC1 to VOS through D1, the internal 1650 W, and the external RDX and RSG resistances. Bias current IOL is supplied from VCTR to ground through D4. A “weak” short to GND can be detected when either VLOAD or RLOAD is absent and the feedback (VOS plus the total voltage rise caused by IOL and the resistance in the path) is less than VOL. When VLOAD and RLOAD are present, a voltage divider between VLOAD and VOS is formed by RLOAD and RSG. A “hard” short to GND may be detected in this case depending on the ratio of RLOAD and RSG and the values of RDX, VLOAD, and VOS. Note that the comparators see a voltage drop or rise due only to the 50 W internal resistance and the bias currents. This produces a small difference in the comparison to the actual feedback voltage at the DRNX input. Several equations for choosing RDX and for predicting open load or short to GND resistances, and a discussion of the dynamic behavior of the short to GND/open load diagnostic are provided in the Applications Information section of this data sheet. OTHER CHANNELS KX VOL DRNX ENA1 − CMP1 + STAB D Q A 500 kHz CLR POR Figure 16. STAB Flag Logic Fault Flag (FLTB) The open−drain active−low fault flag output can be used to provide immediate fault notification to a host controller. Fault detection from all channels is logically ORed to the flag (Figure 17). The FLTB outputs from several devices can be wire−ORed to a common pullup resistor connected to the controller’s 3.3 or 5.0 V VDD supply. The flag is set (low) when a channel detects any fault, the channel’s mask bit (Table 5) is cleared, and both ENAx and CSB are high. The flag is reset (hi−Z) and disabled when either ENA1 or CSB is low. See Table 9 for additional details. KX FAULT X ENA2 OTHER CHANNELS FLTB S Q R ENA1 POR CSB (RESET DOMINANT) Figure 17. FLTB Flag Logic http://onsemi.com 16 NCV7513A Fault Detection and Capture Each channel of the NCV7513A is capable of detecting shorted load faults when the channel is on, and short to ground or open load faults when the channel is off. Each fault type is uniquely encoded into two−bit per channel fault data. A drain feedback input for each channel compares the voltage at the drain of the channel’s external MOSFET to several internal reference voltages. Separate detection references are used to distinguish the three fault types, and blanking and filter timers are used respectively to allow for output state transition settling and for glitch suppression. Fault diagnostics are disabled when either enable input is low. When both enable inputs are high, each channel’s drain feedback input is continuously compared to references appropriate to the channel’s input state to detect faults, but the comparison result is only latched at the end of either a blanking or filter timer event. Blanking timers for all channels are triggered when either enable input changes state from low to high while the other enable input is high, or when both enable inputs go high simultaneously. A single channel’s blanking timer is triggered when its input state changes. If the comparison of the feedback to a reference indicates an abnormal condition when the blanking time ends, a fault has been detected and the fault data is latched into the channel’s fault latch. A channel’s filter timer is triggered when its drain feedback comparison state changes. If the change indicates an abnormal condition when the filter time ends, a fault has been detected and the fault data is latched into the channel’s fault latch. Thus, a state change of the inputs (ENAX, INX or GX) or a state change of an individual channel’s feedback (DRNX) comparison must occur for a timer to be triggered and a detected fault to be captured. flag is reset when CSB goes low at the start of the SPI frame. Fault latches are cleared and re−armed when CSB goes high at the end of the SPI frame only if a valid frame has occurred; otherwise the latches retain the detected fault data until a valid frame occurs. The FLTB flag will be set if a fault is still present. Fault latches for all channels and the FLTB flag can also be cleared and re−armed by toggling ENA1 H−L−H. A full I/O truth table is given in Table 9. Fault Data Readback Examples Several examples are shown to illustrate fault detection, capture and SPI read−back of fault data for one channel. A normal SPI frame returns 16 bits of data but only the two bits of serial data for the single channel are shown for clarity. The examples assume: The NCV7513A is configured as in Figure 2 Both enable inputs are high The channel’s flag mask bit is cleared Disable mode is set to auto−retry The parallel input commands the channel SPI frame is always valid • • • • • • Shorted Load Detected Refer to Figure 18. The channel is commanded on when INX goes high. GATX goes high and the timers are started. At “A”, the STAB flag is set as the DRNX feedback falls through the VOL threshold. A SPI frame sent soon after the INX command returns data indicating “no fault.” The blanking time ends and the filter timer is triggered as DRNX rises through the FLTREF threshold. The STAB flag is reset as DRNX passes through the VOL threshold. DRNX is nearly at VLOAD when the filter time ends at “B”. A shorted load fault is detected and captured by the fault latch, GATX goes low, the FLTB flag is set, and the auto−retry timer is started. An SPI frame sent soon after “B” returns data indicating “shorted load”. The FLTB flag is reset when CSB goes low. At “C” when CSB goes high at the end of the frame, the fault latch is cleared and re−armed. Since INX and the DRNX feedback are unchanged, FLTB and the fault latch are set and the fault is recaptured. When the auto−retry timer ends at “D”, GATX goes high and the blanking and filter timers are started. Since INX and DRNX are unchanged, GATX goes low when the blanking time ends at “E” and the auto−retry timer is started. Read−back data continues to indicate a “shorted load” and the FLTB flag continues to be set while the fault persists. Fault Capture, SPI Communication, and SPI Frame Error Detection The fault capture and frame error detection strategies of the NCV7513A combine to ensure that intermittent faults can be captured and identified, and that the device cannot be inadvertently reprogrammed by a communication error. The NCV7513A latches a fault when it is detected, and frame error detection will not allow any register to accept data if an invalid frame occurred. When a fault has been detected, the FLTB flag is set and fault data is latched into a channel’s fault latch. The latch captures and holds the fault data and ignores subsequent fault data for that channel until a valid SPI frame occurs. Fault data from all channels is transferred from each channel’s fault latch into the SPI shift register and the FLTB http://onsemi.com 17 NCV7513A INx GATx 1 0 FAULT DETECTED 1 0 DRNx VLOAD VOL FLTREF 0 STAB 1 FILTER TIMER 1 FAULT LATCH 1 SO FLTB D 0 BLANK TIMER CSB A 1 0 tFR tBL(ON) 0 0 E B tFR tBL(ON) INTERNAL SIGNALS C tFF 00 11 11 11 11 11 1 0 1 0 00 11 11 1 0 Figure 18. Shorted Load Detected http://onsemi.com 18 11 11 11 NCV7513A Shorted Load Recovery Figure 19 is a continuation of Figure 18. INX is high when the auto−retry timer ends. GATX goes high and the blanking and filter timers are started. The fault is removed before the blanking timer ends, and DRNX starts to fall. As DRNX passes through the VOL threshold at “A”, the STAB flag is set. DRNX continues to fall and settles below the FLTREF threshold. An SPI frame is sent during the blanking time and returns data indicating a “shorted load” fault. Although the fault is removed, updates to the fault latches are suppressed while a blanking or filter timer is active. The same fault is captured again and FLTB is set when CSB goes high. At “B” the blanking time ends and the channel’s fault bits will INx GATx 1 D 0 1 0 FAULT REMOVED VLOAD DRNx indicate “no fault” but because the latched data has not yet been read, the data remains unchanged. The SPI frame sent after the blanking time ends returns a “shorted load” fault because the previous frame occurred during the blanking time. Since the channel’s fault bits indicate “no fault”, FLTB is reset and the fault latch is updated at “C” when CSB goes high. If another SPI frame is sent before “D”, the returned data will indicate “no fault”. The channel is commanded off at “D”. GATX goes low and the timers are started. DRNX starts to rise and the STAB flag is reset as DRNX passes through the VOL threshold. The SPI frame sent at “E” returns data indicating “no fault”. A VOL FLTREF 0 STAB 1 0 BLANK TIMER 1 FILTER TIMER 1 FAULT LATCH 1 CSB SO FLTB B tFR 0 INTERNAL SIGNALS tFF 0 0 tBL(OFF) tBL(ON) 11 11 tFF 11 00 1 C 0 1 0 11 11 11 1 0 Figure 19. Shorted Load Recovery http://onsemi.com 19 E 00 NCV7513A Short to GND/Open Load Figure 20 illustrates turn−off with an open or high resistance load when some capacitance is present at DRNX. In the case of an open load, DRNX rises and settles to VCTR. In the case of a high resistance load, DRNX may continue to rise and may eventually settle to VLOAD. The channel is commanded off. GATX goes low and the timers are started. DRNX starts to rise and is below the VSG threshold when the blanking time ends at “A”. A short to GND fault is detected and captured by the fault latch, and the FLTB flag is set. DRNX continues to rise and as it passes through the VSG threshold at “B”, the filter timer is triggered. At the end of the filter time, the channel’s fault bits will indicate an INx DRNx GATx “open load” but because the latched data has not yet been read, the data remains unchanged. An SPI frame sent shortly after “B” returns data indicating “short to GND” and the fault latch is updated at “C” when CSB goes high. The next three frames sent after “C” return data indicating an “open load”. The STAB flag is reset at “D” as DRNX passes through the VOL threshold. Note that the filter timer is not triggered as DRNX passes from a fault state to a good state. The channel’s fault bits will indicate “no fault” but because the latched data has not yet been read, the data remains unchanged. The fault latch is updated at “E” when CSB goes high and the FLTB flag remains reset. The next SPI frame sent returns data indicating “no fault”. 1 0 1 0 VLOAD VOL VCTR VSG D 0 STAB 1 FILTER TIMER 1 FAULT LATCH 1 SO FLTB B C 0 BLANK TIMER CSB A 1 0 tBL(OFF) tFF 0 0 00 INTERNAL SIGNALS tFF 10 01 01 E 01 00 1 0 1 0 00 10 01 01 1 0 Figure 20. Short to GND/Open Load http://onsemi.com 20 01 00 NCV7513A Table 9. I/O Truth Table Inputs Outputs* POR ENA1 ENA2 CSB KX INX GX DRNX GATX FLTB STAB DX1DX0 0 X X X →0 X →0 X →L →Z →Z →00 1 0 X X X X X X L Z Z 00 ENA1 1 1 0 X KX X GX X L FLTB STAB DX1DX0 ENA2 1 1→0 1 X KX X →0 X →L →Z →Z →00 1 1 1→0 X KX X GX X →L FLTB STAB DX1DX0 1 1 X X 0 X X X L Z Z − FLAGS MASKED 1 1 0 X 1 X X > VOL L − Z − STAB RESET 1 1 0 X 1 X X < VOL L − L − STAB SET 1 1 0 X 1→0 X X < VOL L − L→Z − STAB RESET 1 1 0 X 0→1 X X < VOL L − Z→L − STAB SET 1 1 1 X 1 0 0 > VOL L Z Z 00 FLAGS RESET 1 1 1 1 1 0 0 VSG<V<VOL L L L 01 FLAGS SET 1 1 1 X 1→0 0 0 VSG<V<VOL L L L→Z 01 STAB RESET 1 1 1 X 0→1 0 0 VSG<V<VOL L L 01 STAB SET 1 1 1 1→0 1 0 0 VSG<V<VOL L L→Z L 01 FLTB RESET 1 1 1 0→1 1 0 0 VSG<V<VOL L Z→L L 01 FLTB SET 1 1 1 1 1 0 0 < VSG L L L 10 FLAGS SET 1 1 1 X 1→0 0 0 < VSG L L L→Z 10 STAB RESET 1 1 1 X 0→1 0 0 < VSG L L Z→L 10 STAB SET 1 1 1 1→0 1 0 0 < VSG L L→Z L 10 FLTB RESET 1 1 1 0→1 1 0 0 < VSG L Z→L L 10 FLTB SET 1 1 1 X 1 1 X < VFLTREF H Z L 00 STAB SET 1 1 1 1 1 1 X VFLTREF<V<VOL L L L 11 FLAGS SET 1 1 1 X 1→0 1 X VFLTREF<V<VOL L L L→Z 11 STAB RESET 1 1 1 X 0→1 1 X VFLTREF<V<VOL L L Z→L 11 STAB SET 1 1 1 1→0 1 1 X VFLTREF<V<VOL L L→Z L 11 FLTB RESET 1 1 1 0→1 1 1 X VFLTREF<V<VOL L Z→L L 11 FLTB SET 1 1 1 1 1 1 X > VOL L L Z 11 STAB RESET 1 1 1 X 1 X 1 < VFLTREF H Z L 00 STAB SET 1 1 1 1 1 X 1 VFLTREF<V<VOL L L L 11 FLAGS SET 1 1 1 X 1→0 X 1 VFLTREF<V<VOL L L L→Z 11 STAB RESET 1 1 1 X 0→1 X 1 VFLTREF<V<VOL L L Z→L 11 STAB SET 1 1 1 1→0 1 X 1 VFLTREF<V<VOL L L→Z L 11 FLTB RESET 1 1 1 0→1 1 X 1 VFLTREF<V<VOL L Z→L L 11 FLTB SET 1 1 1 1 1 X 1 > VOL L L Z 11 STAB RESET * Output states after blanking and filter timers end and when channel is set to latch−off mode. http://onsemi.com 21 COMMENT POR RESET ENA1 RESET ENA2 DISABLE NCV7513A APPLICATION GUIDELINES General Unused DRNX inputs should be connected to VCC1 to prevent false open load faults. Unused parallel inputs should be connected to GND and unused enable inputs should be connected to VCC1. The mask bit for each unused channel should be ‘set’ (see Table 5) to prevent activation of the flags and the user’s software should be designed to ignore fault information for unused channels. For best shorted−load detection accuracy, the external MOSFET source terminals should be star−connected and the NCV7513A’s GND pin, and the lower resistor in the fault reference voltage divider should be Kelvin connected to the star (see Figures 2 and 13). Consideration of auto−retry fault recovery behavior is necessary from a power dissipation viewpoint (for both the NCV7513A and the MOSFETs) and also from an EMI viewpoint. Driver slew rate and turn−on/off symmetry can be adjusted externally to the NCV7513A in each channel’s gate circuit by the use of series resistors for slew control, or resistors and diodes for symmetry. Any benefit of EMI reduction by this method comes at the expense of increased switching losses in the MOSFETs. The channel fault blanking timers must be considered when choosing external components (MOSFETs, slew control resistors, etc.) to avoid false faults. Component choices must ensure that gate circuit charge/discharge times stay within the turn−on/turn−off blanking times. The NCV7513A does not have integral drain−gate flyback clamps. Clamp MOSFETs, such as ON Semiconductor’s NID9N05CL, are recommended when driving unclamped inductive loads. This flexibility allows choice of MOSFET clamp voltages suitable to each application. clamp power is limited to the maximum allowable junction temperature. To limit power in the DRNX input clamps and to ensure proper open load or short to GND detection, the RDX resistor must be dimensioned according to the following constraint equations: RDX(MIN) + VPK−VCL(MIN) ICL(MAX) (eq. 2) VSG−|VOS| |ISG| (eq. 3) RDX(MAX) + where VPK is the peak transient drain voltage, VCL is the DRNX input clamp voltage, ICL(MAX) is the input clamp current, and VSG and ISG are the respective short to GND fault detection voltage and diagnostic current, and VOS is the allowable offset (1.0 V max) between the NCV7513A’s GND and the short. Once RDX is chosen, the open load and short to GND detection resistances in the application can be predicted: V −V ROL w LOAD OL * RDX IOL (eq. 4) RLOAD(VSG " VOS−|ISG|RDX) (eq. 5) RSG v VLOAD−VSG ) |ISG|(RDX ) RLOAD) Using the data sheet values for VCL(MIN) = 27 V, ICL(MAX) = 10 mA, and choosing VPK = 55 V as an example, Equation 2 evaluates to 2.8 kW minimum. Choosing VCC1 = 5.0 V and using the typical data sheet values for VSG = 30%VCC1, ISG = 20 mA, and choosing VOS = 0, Equation 3 evaluates to 75 kW maximum. Selecting RDX = 6.8 kW "5%, VCC1 = 5.0 V, VLOAD = 12.0 V, VOS = 0 V, RLOAD = 555 W, and using the typical data sheet values for VOL, IOL, VSG, and ISG, Equation 4 predicts an open load detection resistance of 130.7 kW and Equation 5 predicts a short to GND detection resistance of 71.1 W. When RDX and the data sheet values are taken to their extremes, the open load detection range is 94.1 kW v ROL v 273.5 kW, and the short to GND detection range is 59.2 W v RSG v 84.4 W. DRNX Feedback Resistor Each DRNX feedback input has a clamp to keep the applied voltage below the breakdown voltage of the NCV7513A. An external series resistor (RDX) is required between each DRNX input and MOSFET drain. Channels may be clamped sequentially or simultaneously but total http://onsemi.com 22 NCV7513A PACKAGE DIMENSIONS 32 LEAD LQFP CASE 873A−02 ISSUE C 0.20 (0.008) AB T-U Z 1 −U− −T− B V B1 AE P DETAIL Y BASE METAL V1 17 8 ÉÉ ÉÉ ÉÉ ÉÉ N AE 9 DETAIL Y 4X −Z− 9 F 0.20 (0.008) AC T-U Z S1 S 8X M_ J R D DETAIL AD G −AB− SEATING PLANE AC T-U Z 25 M 32 4X 0.20 (0.008) A −T−, −U−, −Z− A1 SECTION AE−AE C E −AC− DIM A A1 B B1 C D E F G H J K M N P Q R S S1 V V1 W X MILLIMETERS MIN MAX 7.000 BSC 3.500 BSC 7.000 BSC 3.500 BSC 1.400 1.600 0.300 0.450 1.350 1.450 0.300 0.400 0.800 BSC 0.050 0.150 0.090 0.200 0.450 0.750 12_ REF 0.090 0.160 0.400 BSC 1_ 5_ 0.150 0.250 9.000 BSC 4.500 BSC 9.000 BSC 4.500 BSC 0.200 REF 1.000 REF INCHES MIN MAX 0.276 BSC 0.138 BSC 0.276 BSC 0.138 BSC 0.055 0.063 0.012 0.018 0.053 0.057 0.012 0.016 0.031 BSC 0.002 0.006 0.004 0.008 0.018 0.030 12_ REF 0.004 0.006 0.016 BSC 1_ 5_ 0.006 0.010 0.354 BSC 0.177 BSC 0.354 BSC 0.177 BSC 0.008 REF 0.039 REF H W K X DETAIL AD Q_ GAUGE PLANE NOTES: 1. DIMENSIONING AND TOLERANCING PER ANSI Y14.5M, 1982. 2. CONTROLLING DIMENSION: MILLIMETER. 3. DATUM PLANE −AB− IS LOCATED AT BOTTOM OF LEAD AND IS COINCIDENT WITH THE LEAD WHERE THE LEAD EXITS THE PLASTIC BODY AT THE BOTTOM OF THE PARTING LINE. 4. DATUMS −T−, −U−, AND −Z− TO BE DETERMINED AT DATUM PLANE −AB−. 5. DIMENSIONS S AND V TO BE DETERMINED AT SEATING PLANE −AC−. 6. DIMENSIONS A AND B DO NOT INCLUDE MOLD PROTRUSION. ALLOWABLE PROTRUSION IS 0.250 (0.010) PER SIDE. DIMENSIONS A AND B DO INCLUDE MOLD MISMATCH AND ARE DETERMINED AT DATUM PLANE −AB−. 7. DIMENSION D DOES NOT INCLUDE DAMBAR PROTRUSION. DAMBAR PROTRUSION SHALL NOT CAUSE THE D DIMENSION TO EXCEED 0.520 (0.020). 8. MINIMUM SOLDER PLATE THICKNESS SHALL BE 0.0076 (0.0003). 9. EXACT SHAPE OF EACH CORNER MAY VARY FROM DEPICTION. 0.250 (0.010) 0.10 (0.004) AC FLEXMOS and SMARTDISCRETES are trademarks of Semiconductor Components Industries, LLC (SCILLC). ON Semiconductor and are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. SCILLC does not convey any license under its patent rights nor the rights of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where personal injury or death may occur. Should Buyer purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture of the part. SCILLC is an Equal Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner. PUBLICATION ORDERING INFORMATION LITERATURE FULFILLMENT: Literature Distribution Center for ON Semiconductor P.O. Box 5163, Denver, Colorado 80217 USA Phone: 303−675−2175 or 800−344−3860 Toll Free USA/Canada Fax: 303−675−2176 or 800−344−3867 Toll Free USA/Canada Email: [email protected] N. American Technical Support: 800−282−9855 Toll Free USA/Canada Europe, Middle East and Africa Technical Support: Phone: 421 33 790 2910 Japan Customer Focus Center Phone: 81−3−5773−3850 http://onsemi.com 23 ON Semiconductor Website: www.onsemi.com Order Literature: http://www.onsemi.com/orderlit For additional information, please contact your loca Sales Representative NCV7513A/D