LITTELFUSE B1101U_4L

Battrax® Dual Port Negative SLIC Protector
RoHS
(R)
4
Ground
5
This Battrax device is an integrated overvoltage protection solution for SLIC-based
(Subscriber Line Interface Circuit) line cards. This six-pin device is constructed using
four SCRs and four gate diodes.
The device is referenced to VBAT and conducts when a voltage that is more negative
than -VREF is applied to the cathode (Pins 1, 3, 4, or 6) of the SCR. During
conduction, all negative transients are shorted to Ground. All positive transients are
passed to Ground by the diodes.
1
(T)
3
(R)
2
(-VREF)
For specific diagrams showing these Battrax applications, see Figure 6.48 in
Section 6, “Reference Designs” of this Telecom Design Guide.
Electrical Parameters
Part
Number *
VDRM
Volts
VS
Volts
VT
Volts
IDRM
µAmps
IGT
mAmps
IT
Amps
IH
mAmps
100
B1101U_ 4L
|-VREF| + |-1.2V|
|-VREF| + |-10V|
4
5
100
2.2
B1161U_ 4L
|-VREF| + |-1.2V|
|-VREF| + |-10V|
4
5
100
2.2
160
B1201U_ 4L
|-VREF| + |-1.2V|
|-VREF| + |-10V|
4
5
100
2.2
200
* “L” in part number indicates RoHS compliance. For non-RoHS compliant device, delete “L” from part number.
For individual “UA” and “UC” surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• IPP ratings assume a VREF = ±48 V.
• VDRM is measured at IDRM.
• VS is measured at 100 V/µs.
• VREF maximum value for the negative Battrax is -200 V.
Surge Ratings in Amps
Series
IPP
0.2x310 * 2x10 *
8x20 *
0.5x700 ** 2x10 ** 1.2x50 **
10x160 *
10x160 **
10x560 *
10x560 **
5x320 *
9x720 **
Amps
Amps
Amps
10x360 * 10x1000 * 5x310 *
ITSM
10x360 ** 10x1000 ** 10x700 ** 50 / 60 Hz
Amps
Amps
Amps
Amps
A
20
150
150
90
50
75
75
C
50
500
400
200
150
200
175
Amps
di/dt
Amps
Amps
Amps/µs
45
75
20
500
100
200
50
500
* Current waveform in µs
** Voltage waveform in µs
Telecom Design Guide • © 2006 Littelfuse
3 - 81
www.littelfuse.com
SIDACtor Devices
(T)
6
Battrax® Dual Port Negative SLIC Protector
Thermal Considerations
Package
Symbol
Modified MS-013
TJ
Operating Junction Temperature Range
-40 to +125
°C
TS
Storage Temperature Range
-65 to +150
°C
60
°C/W
6
5
Parameter
Thermal Resistance: Junction to Ambient
RθJA
4
Value
Unit
1
2
3
Capacitance Values
pF
Part Number
B1101UA 4L
B1101UC 4L
B1161UA 4L
B1161UC 4L
B1201UA 4L
B1201UC 4L
MIN
50
50
50
50
50
50
MAX
200
200
200
200
200
200
Note: Off-state capacitance (CO) is measured at 1 MHz with a 2 V bias.
IPP – Peak Pulse Current – %IPP
+I
VF
VS VDRM
VT
-V
IDRM
+V
IH
IGT
IT
100
50
0
tr
td
t – Time (µs)
10
IH
8
6
25 ˚C
4
2
IH (TC = 25 ˚C)
tr x td Pulse Waveform
Ratio of
Percent of VS Change – %
Half Value
0
14
12
0
-4
-6
2.0
1.8
1.6
1.4
25 ˚C
1.2
1.0
0.8
0.6
0.4
-40 -20 0
-8
-40 -20
0
20 40 60 80 100 120 140 160
Normalized VS Change versus Junction Temperature
20 40 60 80 100 120 140 160
Case Temperature (TC) – ˚C
Junction Temperature (TJ) – ˚C
www.littelfuse.com
tr = rise time to peak value
td = decay time to half value
Waveform = tr x td
-I
V-I Characteristics
Peak
Value
Normalized DC Holding Current versus Case Temperature
3 - 82
© 2006 Littelfuse • Telecom Design Guide