Termseries Interface Adapter Datasheet

Datasheet
TERMSERIES Interface Adapter (TIA)
NEW
Extensive wiring complexity leads to high throughput times in
electrical cabinets. Thanks to our TERMSERIES interface adapter, you
benefit from the speed of our plug-and-play solution. Let’s connect.
To reduce wiring times, pre-assembled lines are used between the
controller and interface level and are simply connected to the
TERMSERIES adapter. This enables electrical cabinet throughput
times to be significantly reduced.
Our pre-assembled plug-and-play solution with TERMSERIES interface
adapter minimizes wiring complexity. The adapter has a universal
fit and offers a genuine space advantage in conjunction with
TERMSERIES products with identical contours.
Thanks to its symmetrical structure, the adapter can be connected
to both TERMSERIES coil and contact connections. The use of
positive (PNP) and negative (NPN) switching logic is also possible for
the lower level with the aid of the potential changeover switch.
Weidmuller, Canada
10 Spy Court
Markham, Ontario L3R 5H6
Telephone: (800) 268-4080
Facsimile: (877) 300-5635
Email: [email protected]
Website: www.weidmuller.ca
Weidmuller, Mexico
Blvd. Hermanos Serdán 698,
Col. San Rafael Oriente
Puebla, Puebla, Mexico
C.P. 72029
Telephone: 01 222 2686267
Facsimile: 01 222 2686219
Email: [email protected]
Website: www.weidmuller.com.mx
Weidmuller, United States
821 Southlake Blvd.
Richmond, Virginia 23236
Telephone: (800) 849-9343
Facsimile: (804) 379-2593
Email: [email protected]
Website: www.weidmuller.com
TERMSERIES Interface Adapter (TIA)
Connection to a variety of controllers
The standardized ribbon cable plug-in
connections enable connection of all the
interface system's pre-assembled cable types.
Fast supply and bridging of the
auxiliary voltage
Quick and safe supply of the auxiliary voltage as
a result of the TOP connection with "PUSH IN"
technology. Simple bridging is also possible
thanks to duplication of the connections.
Reliable and unambiguous wiring
Installation is unambiguous and safe thanks
to practical marking of the connections,
assignment of the contacts and the option of
individual marking using MultiCard.
Both types of logic with one device
The potential switch for the lower level allows
the adapter for plus and minus switching logic
to be used (PNP/NPN).
2
Connection with our remote I/O
system u-remote
Use our perfectly matched cable
harness for connecting our u-remote
DI/DO sub assemblies and
TERMSERIES relays.
TERMSERIES Interface Adapter (TIA)
Applications
The TIA can be used together with TERMSERIES relay and
optocoupler products, resulting in substantial space-savings.
Its symmetrical design means the TIA can be plugged onto
both the TERMSERIES input coil connections and/or output
contact connections.
The TIA’s new contact system creates a spring-loaded effect,
thus guaranteeing reliable contact at all times – even in
vibration applications. It visually and audibly snaps into place,
providing the user with valuable feedback to indicate secure
connection is made into the relay terminal block.
Connections to the u-remote
TIAs can also be combined with Weidmuller’s new remote I/O
system (u-remote), connect the u-remote DI/DO sub-assemblies
using form-fit cable sets for the TERMSERIES relay adapter.
Connections with Flying Leads
The TIA can be used with a flying lead cable to give flexibility
in wiring the relays or optocouplers to another connector
location. The cabling solution is a simple, speedy, configurable
and space saving means to wire your electrical cabinet.
Connect to u-remote
20-Pin Connector
Flying Ferrule Leads
Connections for PLC Interfaces
The TIA and cabling solutions can also be used to create
simple, easy and accurate connection solutions for many PLC
manufacturers’ products. See Catalog 4.5 Interface Units & PLC
Solutions for a listing of these solutions.
CSA/UL Approved Cables
3
TERMSERIES Interface Adapter (TIA)
TERMSERIES adapters
TIA F10
Potential change-over switch
•S
uitable for input and output logic
•V
ersion for 6.4 mm TERMSERIES base
•S
upply connections (PUSH IN)
designed double for simple supply
voltage bridging
•U
ser-friendly and unique markings
•1
0-pole connecting plug according to
DIN EN 60603-13
The potential change-over switch is located between contact rows of
the TERMSERIES adapter. It is used to switch the potential of the lower
contact row to “+” or “-“ potential of the supply voltage.
9'&
²
²
Installation input
A1
24V
A2
TOS
24V
A1 +
A2 -
NC
TRS 24VDC 1CO
1122770000
Figure 1a
Figure 1b
Installation output
NO
14 11
62 / 51 / 43
COM
2
III
1.5 kV
32 V
IP 20
11
-40°C...+60°C
-40°C...+85°C
5...95% (indoor), Tu = 40°C, no condensation
V-0
cULus Listed, GL, CE
Figure 1a:Positive-switching logic (PNP): Potential change-over
switch to “-“, installation on 24 V DC input (A1/A2).
Figure 1b:Negative-switching logic (NPN): Potential change-over
switch to “+”, installation on ONLY 24 V UC units.
14
10-pole plug according to DIN EN 60603-13,
long locking lever
A1
14 11 12
Cables
10 pin to flying ferruled leads
10 pin to flying ferruled leads
10 pin to flying ferruled leads
10 pin to 10 pin connectors
10 pin to 10 pin connectors
10 pin to 10 pin connectors
Note
4
Part No.
1463520000
Suitable for 6.4 mm wide TERMSERIES base
TRS 24VDC 1CO
1122770000
Accessories
Qty.
1
NC
Note
Type
TIA F10
12
Ordering data
Figure 2a
Figure 2b
Description
SP-CBL-TIAU-10-F 0.5M
SP-CBL-TIAU-10-F 1M
SP-CBL-TIAU-10-F 2M
SP-CBL-TIAU-10-10 0.5M
SP-CBL-TIAU-10-10 1M
SP-CBL-TIAU-10-10 2M
Length
0.5 m
1.0 m
2.0 m
0.5 m
1.0 m
2.0 m
Part No.
6720000965
6720000966
6720000967
6720000960
6720000961
6720000962
other lengths available upon request and see page 8 for additional cables
Figure 2a:Positive-switching logic (sourced loads): Potential
change-over switch to “+”, installation on output (11/14).
Figure 2b:Negative-switching logic (sinked loads): Potential
change-over switch to “-“, installation on output (11/14).
12
A2
TRS
14 11 12
A1
PUSH IN
0.13 mm²
1.5 mm²
4 (+,+,−,−)
mm
14 11
24 V DC
30 V DC
100 mA
1A
1A
8
COM
NO
General data
Ambient temperature (operational)
Storage temperature
Humidity
UL 94 flammability rating
Agency Approvals
Insulation coordination
Pollution degree
Overvoltage category
Impulse withstand voltage
Rated voltage
Protection degree
Dimensions
Depth x width x height
Note
24 V DC ± 20%
Green LED
11
Supply
Supply voltage
Status display
Signals
Rated voltage
Voltage, max.
Rated current (per signal path)
Current (per signal path), max.
Total current of all signals, max.
Number of signal paths
Connection data (supply)
Wire connection method
Clamping range, rated connection, min.
Clamping range, rated connection, max.
Number of terminals
Connection data (signal)
Plug type
14
Technical data
TERMSERIES Interface Adapter (TIA)
TERMSERIES adapters
TIAL F10
Potential change-over switch
•S
uitable for input and output logic
•V
ersion for 12.8 mm TERMSERIES
base
•S
upply connections (PUSH IN)
designed double for simple supply
voltage bridging
•U
ser-friendly and unique markings
•1
0-pole connecting plug according to
DIN EN 60603-13
The potential change-over switch is located between contact rows of
the TERMSERIES adapter. It is used to switch the potential of the lower
contact row to “+” or “-“ potential of the supply voltage.
9'&
²
²
Installation input
12
A1
24V
A2
TOS
A2
TRS
14 11 12
A1
24V
A1 +
A2 -
NC
TRS 24VDC 1CO
1122770000
PUSH IN
0.13 mm²
1.5 mm²
4 (+,+,−,−)
Figure 1a
Figure 1b
Installation output
NO
14 11
62 / 102 / 43
COM
2
III
1.5 kV
32 V
IP 20
11
-40°C...+60°C
-40°C...+85°C
5...95% (indoor), Tu = 40°C, no condensation
V-0
cULus Listed, GL, CE
Figure 1a:Positive-switching logic (PNP): Potential change-over
switch to “-“, installation on 24 V DC input (A1/A2).
Figure 1b:Negative-switching logic (NPN): Potential change-over
switch to “+”, installation on ONLY 24 V UC units.
14
10-pole plug according to DIN EN 60603-13,
long locking lever
A1
mm
14 11
24 V DC
30 V DC
100 mA
1A
1A
8
COM
NO
General data
Ambient temperature (operational)
Storage temperature
Humidity
UL 94 flammability rating
Agency Approvals
Insulation coordination
Pollution degree
Overvoltage category
Impulse withstand voltage
Rated voltage
Protection degree
Dimensions
Depth x width x height
Note
24 V DC ± 20%
Green LED
11
Supply
Supply voltage
Status display
Signals
Rated voltage
Voltage, max.
Rated current (per signal path)
Current (per signal path), max.
Total current of all signals, max.
Number of signal paths
Connection data (supply)
Wire connection method
Clamping range, rated connection, min.
Clamping range, rated connection, max.
Number of terminals
Connection data (signal)
Plug type
14
Technical data
14 11 12
Cables
10 pin to flying ferruled leads
10 pin to flying ferruled leads
10 pin to flying ferruled leads
10 pin to 10 pin connectors
10 pin to 10 pin connectors
10 pin to 10 pin connectors
Note
Part No.
1463540000
Suitable for 12.8 mm wide TERMSERIES base
TRS 24VDC 1CO
1122770000
Accessories
Qty.
1
NC
Note
Type
TIAL F10
12
Ordering data
Figure 2a
Figure 2b
Description
SP-CBL-TIAU-10-F 0.5M
SP-CBL-TIAU-10-F 1M
SP-CBL-TIAU-10-F 2M
SP-CBL-TIAU-10-10 0.5M
SP-CBL-TIAU-10-10 1M
SP-CBL-TIAU-10-10 2M
Length
0.5 m
1.0 m
2.0 m
0.5 m
1.0 m
2.0 m
Part No.
6720000965
6720000966
6720000967
6720000960
6720000961
6720000962
Figure 2a:Positive-switching logic (sourced loads): Potential changeover switch to “+”, installation on output (11/14).
Figure 2b:Negative-switching logic (sinked loads): Potential changeover switch to “-“, installation on output (11/14).
other lengths available upon request and see page 8 for additional cables
5
TERMSERIES Interface Adapter (TIA)
TERMSERIES adapters
TIAL F20
•S
uitable for input and output logic
•V
ersion for 6.4 mm TERMSERIES base
•S
upply connections (PUSH IN) designed
double for simple supply voltage
bridging
•U
ser-friendly and unique markings
•2
0-pole connecting plug according to
DIN EN 60603-13
Potential change-over switch
The potential change-over switch is located between contact rows of
the TERMSERIES adapter. It is used to switch the potential of the lower
contact row to “+” or “-“ potential of the supply voltage.
9'&
²
²
Installation input
A1
24V
A2
TOS
A2
TRS
14 11 12
12
A1
24V
A1 +
A2 -
NC
TRS 24VDC 1CO
1122770000
PUSH IN
0.13 mm²
1.5 mm²
4 (+,+,−,−)
Figure 1a
Figure 1b
Installation output
NO
14 11
62 / 102 / 43
COM
2
III
1.5 kV
32 V
IP 20
11
-40°C...+60°C
-40°C...+85°C
5...95% (indoor), Tu = 40°C, no condensation
V-0
cULus Listed, GL, CE
Figure 1a:Positive-switching logic (PNP): Potential change-over
switch to “-“, installation on 24 V DC input (A1/A2).
Figure 1b:Negative-switching logic (NPN): Potential change-over
switch to “+”, installation on ONLY 24 V UC units.
14
20-pole plug according to DIN EN 60603-13,
long locking lever
A1
mm
14 11
24 V DC
30 V DC
100 mA
1A
2A
16
COM
NO
General data
Ambient temperature (operational)
Storage temperature
Humidity
UL 94 flammability rating
Agency Approvals
Insulation coordination
Pollution degree
Overvoltage category
Impulse withstand voltage
Rated voltage
Protection degree
Dimensions
Depth x width x height
Note
24 V DC ± 20%
Green LED
11
Supply
Supply voltage
Status display
Signals
Rated voltage
Voltage, max.
Rated current (per signal path)
Current (per signal path), max.
Total current of all signals, max.
Number of signal paths
Connection data (supply)
Wire connection method
Clamping range, rated connection, min.
Clamping range, rated connection, max.
Number of terminals
Connection data (signal)
Plug type
14
Technical data
14 11 12
Cables
20 pin to flying ferruled eads
20 pin to flying ferruled leads
20 pin to flying ferruled leads
20 pin to 20 pin connectors
20 pin to 20 pin connectors
20 pin to 20 pin connectors
Note
6
Qty.
1
Part No.
1463550000
Suitable for 6.4 mm wide TERMSERIES base
TRS 24VDC 1CO
1122770000
Accessories
NC
Note
Type
TIAL F20
12
Ordering data
Figure 2a
Figure 2b
Description
SP-CBL-TIAU-20-F, 0.5M
SP-CBL-TIAU-20-F 1M
SP-CBL-TIAU-20-F 2M
SP-CBL-TIAU-20-20 0.5M
SP-CBL-TIAU-20-20 1M
SP-CBL-TIAU-20-20 2M
Length
0.5 m
1.0 m
2.0 m
0.5 m
1.0 m
2.0 m
Part No.
6720000950
6720000951
6720000952
6720000945
6720000946
6720000947
other lengths available upon request and see page 8 for additional cables
Figure 2a:Positive-switching logic (sourced loads): Potential changeover switch to “+”, installation on output (11/14).
Figure 2b:Negative-switching logic (sinked loads): Potential changeover switch to “-“, installation on output (11/14).
TERMSERIES Interface Adapter (TIA)
TERMSERIES adapters
TIA SUBD 15S
•S
uitable for input and output logic
•V
ersion for 6.4 mm TERMSERIES base
•U
ser-friendly and unique markings
•1
5-pole sub-D plug according to
DIN 41652 / IEC 60807
Potential change-over switch
The potential change-over switch is located between contact rows of
the TERMSERIES adapter. It is used to switch the potential of the lower
contact row to “+” or “-“ potential of the supply voltage.
TRS 24VDC 1CO
14 NO
NC 1122770000
12
14 11 12
24V
A1
24V
A2
A1
A2
Figure
Figure 1a
1b
14 11 12
NC
A1
Figure 1b
A1 +
24V
A1 +
A2 -
24V
A2
24V
A1 +
A2 -
Figure 1a:Positive-switching logic (PNP): Potential change-over
switch to “-“, installation on 24 V DC input (A1/A2).
Figure 1b:Negative-switching logic (NPN): Potential change-over
1a units.
switch to “+”, installation on ONLYFigure
24 V UC
12
24V
A2 -
Figure 1a
COM
11 TRS
24VDC141CO
11
1122770000
TOS
TRS
A2A2
TOS
NC
12
A1
TRS
A1
14 11
11 12
14
A2
TRS
COM
11
A1
TRS 24VDC 1CO
1122770000
PUSH IN
0.13 mm²
1.5 mm²
2 (+,−)
Installation output
Figure 1b
Sub-D, 15-pole, DIN 41652 / IEC 60807
NO
14
COM
COM
11
A1
14 11
A1
14 11
14 11 12
NC
12
TRS 24VDC 1CO
14 NO
NC 1122770000
12
14 11 12
52 / 51 / 43
Figure 2a
COM
11 TRS
24VDC141CO
11
1122770000
mm
11
2
III
1.5 kV
32 V
IP 20
NO
-40°C...+60°C
-40°C...+85°C
5...95% (indoor), Tu = 40°C, no condensation
V-0
cULus Listed, GL, CE
14
A1
Figure 2b
2a
Figure
Figure 2a:Positive-switching logic (sourced loads): Potential change2b
over switch to “+”, installation on Figure
output (11/14).
Figure 2b:Negative-switching logic (sinked loads): Potential changeover switch to “-“, installation on output (11/14).
14 11 12
Part No.
1463530000
Suitable for 6.4 mm wide TERMSERIES base
Description
PAC-UNIV-D15M-F-1M
Length
1.0 m
Part No.
1350420010
TRS 24VDC 1CO
1122770000
Qty.
1
NC
Type
TIA SUBD 15S
12
Cables
DB 15 to flying ferruled leads
Note
14 11
Accessories
NO
Note
24 V DC
30 V DC
100 mA
1A
1A
8
14
Ordering data
24 V DC ± 20%
Green LED
COM
Supply
Supply voltage
Status display
Signals
Rated voltage
Voltage, max.
Rated current (per signal path)
Current (per signal path), max.
Total current of all signals, max.
Number of signal paths
Connection data (supply)
Wire connection method
Clamping range, rated connection, min.
Clamping range, rated connection, max.
Number of terminals
Connection data (signal)
Plug type
General data
Ambient temperature (operational)
Storage temperature
Humidity
UL 94 flammability rating
Agency Approvals
Insulation coordination
Pollution degree
Overvoltage category
Impulse withstand voltage
Rated voltage
Protection degree
Dimensions
Depth x width x height
Note
NO
Technical data
14
²
TOS
Installation input
11
9'&
²
Figure 2a
Figure 2b
other lengths available upon request. These cables do not have CSA or UL approval.
15 Pin D Sub to Flying Ferruled Leads
7
TERMSERIES Interface Adapter (TIA)
CSA/UL Recognized Cables and Connectors
Physical Characteristics
Conductor
Insulation
Cable
Jacket
Electrical Characteristics
Temperature
Suggested Working Voltage (Vrms)
Conductor D.C. Resistance
Mutual Capacitance
Approvals
#22 AWG 7/30 Tinned Copper,
0.030“ nom. diameter
0.010“ Wall Semi-Rigid Polyvinyl Chloride,
0.050“ nom. diameter
20 conductors @ 4.5“ LHL with mylar
wrap, 0.270“ nom. diameter
0.032“ Wall Polyvinyl Chloride,
0.334“ +/- 0.017“ diameter
75°C
300Vrms
16.6 Ohms/1000 ft nom
24.5 pF/ft @ 1kHz nom
National Electrical Code, Article 800
UL Standard 444, Type CM
UL Standard 758, AWM Style 2464
CSA International, Type CMG
RoHS Compliant, Directive 2002/95/EC
10 pin connector to 10 pin connector
(1:1)
20 pin to flying ferruled leads
20 pin connector to 20 pin connector
(1:1)
20 pin to 2 x 10 pin connectors
Note
8
10 Pin to Flying Ferruled Leads
20 Pin Connector to 20 Pin Connector
Ordering Data
10 pin to flying ferruled leads
Color Code
1
Black
2
White
3
Red
4
Lt. Green
5
Orange
6
Blue
7
White/Black
8
Red/Black
9
Green/Black
10
Orange/Black
11
Blue/Black
12
Black/White
13
Red/White
14
Green/White
15
Blue/White
16
Black/Red
17
White/Red
18
Orange/Red
19
Blue/Red
20
Red/Green
Length*
0.5 m
1.0 m
2.0 m
3.0 m
5.0 m
0.5 m
1.0 m
2.0 m
3.0 m
5.0 m
0.5 m
1.0 m
2.0 m
3.0 m
5.0 m
0.5 m
1.0 m
2.0 m
3.0 m
5.0 m
0.5 m
1.0 m
2.0 m
3.0 m
5.0 m
Description
SP-CBL-TIAU-10-F 0.5M
SP-CBL-TIAU-10-F 1M
SP-CBL-TIAU-10-F 2M
SP-CBL-TIAU-10-F 3M
SP-CBL-TIAU-10-F 5M
SP-CBL-TIAU-10-10 0.5M
SP-CBL-TIAU-10-10 1M
SP-CBL-TIAU-10-10 2M
SP-CBL-TIAU-10-10 3M
SP-CBL-TIAU-10-10 5M
SP-CBL-TIAU-20-F 0.5M
SP-CBL-TIAU-20-F 1M
SP-CBL-TIAU-20-F 2M
SP-CBL-TIAU-20-F 3M
SP-CBL-TIAU-20-F 5M
SP-CBL-TIAU-20-20 0.5M
SP-CBL-TIAU-20-20 1M
SP-CBL-TIAU-20-20 2M
SP-CBL-TIAU-20-20 3M
SP-CBL-TIAU-20-20 5M
SP-CBL-TIAU-20-2X10 0.5M
SP-CBL-TIAU-20-2X10 1M
SP-CBL-TIAU-20-2X10 2M
SP-CBL-TIAU-20-2X10 3M
SP-CBL-TIAU-20-2X10 5M
Part No.
6720000965
6720000966
6720000967
6720000968
6720000969
6720000960
6720000961
6720000962
6720000963
6720000964
6720000950
6720000951
6720000952
6720000953
6720000954
6720000945
6720000946
6720000947
6720000948
6720000949
6720000955
6720000956
6720000957
6720000958
6720000959
20 Pin to 2 x 10 Pin Connectors
*other lengths available upon request
Subject to technical changes • 08/15 • LIT1419E