Clearwall™ Curtain Wall System OCTOBER, 2015 1 FEATURES EC 97911-084 Features • ClearwallTM is a 4-sided Toggle Glazed (TG) curtain wall system Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. • Achieves an all-glass monolithic aesthetic in a field glazed; screw spline or shear block fabricated application • 5/8" (15.9) exterior vertical and horizontal weatherseal sightline • 2-1/2" (63.5) interior metal sightline • Innovative toggle assembly captures glass, eliminating field application of structural silicone • All three glazing options, use the toggle based glass retention system • ClearwallTM SS (Screw Spline) or SB (Shear Block) • Toggles capture 1-1/8" (28.6) insulating glass unit, with a recessed spacer • Inside lite of insulating glass unit is directly engaged by toggles • No structural silicone required • ClearwallTM SSI (Screw Spline Interface) or SBI (Shear Block Interface) • Toggles capture standard 1" (25.4) insulating glass unit attached with shop applied metal interface using structural silicone • ClearwallTM SSIT (Screw Spline Interface Tape) or SBIT (Shear Block Interface Tape) • Toggles capture standard 1" (25.4) insulating glass unit attached with shop applied metal interface using 3M™ VHB™ SGT (Structural Glazing Tape) • Screw spline joinery method allows shop assembly of ladder sections, reducing field labor • Shear Block joinery and deeper mullions allow for higher free-spans (up to 26' with steel reinforcing) • ClearwallTM can be supplied fabricated and KD, or in stock lengths • Offers integrated entrance framing systems • Two color option • PermanodicTM anodized finishes in seven choices • Painted finishes in standard and custom choices • Comprehensively tested to latest high performance standards • Full technical support from 3MTM for application of the 3M™ VHB™ SGT (Structural Glazing Tape) for ClearwallTM SSIT and SBIT © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. • Silicone compatible EPDM glazing materials for long-lasting seals Optional Features • Air barrier and back pan applications available • Profit$MakerTM Plus die sets available Product Applications • Ideal for low-rise applications of four floors or less requiring a sleek, uninterrupted all-glass facade • Ideal for office buildings, and lobbies or accent walls of high profile buildings For specific product applications, Consult your Kawneer representative. kawneer.com ADMD100EN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Clearwall™ Curtain Wall System BLANK PAGE ADMD100EN kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 OCTOBER, 2015 EC 97911-084 OCTOBER, 2015 Clearwall™ Curtain Wall System 3 INDEX EC 97911-084 Architects – Most extrusions illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. PICTORIAL VIEW................................................................................. 5 TYPICAL 1/4 SIZE DETAILS................................................................ 6 SCREW SPLINE (SS)..................................................................... 6 SCREW SPLINE INTERFACE (SSI)............................................... 7 SCREW SPLINE INTERFACE TAPE (SSIT).................................. 8 SHEAR BLOCK (SB)...................................................................... 9 SHEAR BLOCK INTERFACE (SBI)............................................. 10 SHEAR BLOCK INTERFACE TAPE (SBIT)................................. 11 CORNERS........................................................................................... 12 90° OUTSIDE SINGLE MULLION CORNERS................................... 13 ANCHORING................................................................................. 14-15 WIND LOAD CHARTS................................................................... 16-24 DEADLOAD CHARTS........................................................................ 25 THERMAL CHARTS...................................................................... 26-45 The following metric (SI ) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADMD100EN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Clearwall™ Curtain Wall System BLANK PAGE ADMD100EN kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 OCTOBER, 2015 EC 97911-084 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. OCTOBER, 2015 kawneer.com Clearwall™ Curtain Wall System EC 97911-084 PICTORIAL VIEW CLEARWALLTM SS (Screw Spline) shown ADMD100EN 5 Clearwall™ Curtain Wall System 6 OCTOBER, 2015 SCREW SPLINE (SS) DETAILS EC 97911-084 SCALE 3" = 1'-0" 1 VARIES PER PROJECT ANCHOR DETAILS PAGE 14 & 15 5 4 2 7 2 HORIZONTAL CORNER DETAILS PAGE 12 &13 2-1/2" (63.5) 2 5-1/8" (130.2) 6-5/8" (168.3) ENTRANCE DETAILS 6 3 5-1/8" (130.2) 6-5/8" (168.3) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3 SILL ELEVATION IS NUMBER KEYED TO DETAILS 7/8" (22.2) 2-1/2" (63.5) 4 JAMB 5 VERTICAL INTERMEDIATE 6 DOOR JAMB BUTT HUNG OR OFFSET PIVOT 7 DOOR JAMB BUTT HUNG OR OFFSET PIVOT Note: 1-1/8" (28.6) insulating glass unit with recessed spacer by qualified Insulated Glass Unit (IGU) manufacturer. ADMD100EN kawneer.com © Kawneer Company, Inc., 2013 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 HEAD 2 © Kawneer Company, Inc., 2013 6" (152.4) 7-1/2" (190.5) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2-1/2" (63.5) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. OCTOBER, 2015 4 JAMB kawneer.com Clearwall™ Curtain Wall System EC 97911-084 SCREW SPLINE INTERFACE (SSI) DETAILS SCALE 3" = 1'-0" 1 VARIES PER PROJECT 2 4 1 HEAD ANCHOR DETAILS PAGE 14 & 15 2 5 7 2 CORNER DETAILS PAGE 12 &13 5 VERTICAL INTERMEDIATE 2 HORIZONTAL ENTRANCE DETAILS 6 6" (152.4) 7-1/2" (190.5) 3 ELEVATION IS NUMBER KEYED TO DETAILS 3 SILL 2-1/2" (63.5) 7/8" (22.2) 6 DOOR JAMB BUTT HUNG OR OFFSET PIVOT ADMD100EN 7 DOOR JAMB BUTT HUNG OR OFFSET PIVOT 7 Clearwall™ Curtain Wall System 8 OCTOBER, 2015 SCREW SPLINE INTERFACE TAPE (SSIT) DETAILS EC 97911-084 SCALE 3" = 1'-0" 1 VARIES PER PROJECT ANCHOR DETAILS PAGE 14 & 15 2-1/2" (63.5) 2 5 4 CORNER DETAILS PAGE 12 &13 2 7 2 HORIZONTAL 5-7/8" (149.2) ENTRANCE DETAILS 7-3/8" (187.3) 6 3 5-7/8" (149.2) 7-3/8" (187.3) 7/8" (22.2) 2-1/2" (63.5) 4 JAMB 5 VERTICAL INTERMEDIATE Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3 SILL ELEVATION IS NUMBER KEYED TO DETAILS 6 DOOR JAMB BUTT HUNG OR OFFSET PIVOT 7 DOOR JAMB BUTT HUNG OR OFFSET PIVOT Note: Metal interface uses 3M™ VHB™ SGT (Structural Glazing Tape) ADMD100EN kawneer.com © Kawneer Company, Inc., 2013 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 HEAD 2 Clearwall™ Curtain Wall System OCTOBER, 2015 SHEAR BLOCK (SB) DETAILS EC 97911-084 SCALE 3" = 1'-0" VARIES PER PROJECT 1 2 2-1/2" (63.5) ANCHOR DETAILS PAGE 14 & 15 2 5 4 CORNER DETAILS PAGE 12 &13 2 7 2 HORIZONTAL 10-1/8" (257.2) ENTRANCE DETAILS 6 3 3 SILL ELEVATION IS NUMBER KEYED TO DETAILS 7 2-1/2" (63.5) 4 JAMB 5 VERTICAL INTERMEDIATE BUTT HUNG OR OFFSET PIVOT (257.2) 10-1/8" DOOR JAMB © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 HEAD 7/8" (22.2) 6 DOOR JAMB BUTT HUNG OR OFFSET PIVOT Note: 1-1/8" (28.6) insulating glass unit with recessed spacer by qualified Insulated Glass Unit (IGU) manufacturer. kawneer.com ADMD100EN 9 11" 1 2 ANCHOR DETAILS PAGE 14 & 15 5 7 4 JAMB 2 CORNER DETAILS PAGE 12 &13 ENTRANCE DETAILS 6 3 2-1/2" (63.5) 5 VERTICAL INTERMEDIATE 2 HORIZONTAL (279.4) 11" 3 SILL ELEVATION IS NUMBER KEYED TO DETAILS ADMD100EN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SHEAR BLOCK INTERFACE (SBI) DETAILS 7 DOOR JAMB BUTT HUNG OR OFFSET PIVOT 7/8" (22.2) 6 DOOR JAMB BUTT HUNG OR OFFSET PIVOT kawneer.com © Kawneer Company, Inc., 2013 2 2-1/2" (63.5) Clearwall™ Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 (279.4) 10 OCTOBER, 2015 EC 97911-084 SCALE 3" = 1'-0" VARIES PER PROJECT 1 HEAD Clearwall™ Curtain Wall System OCTOBER, 2015 SHEAR BLOCK INTERFACE TAPE (SBIT) DETAILS EC 97911-084 SCALE 3" = 1'-0" VARIES PER PROJECT 1 2 2-1/2" (63.5) ANCHOR DETAILS PAGE 14 & 15 2 5 4 7 CORNER DETAILS PAGE 12 &13 2 ENTRANCE DETAILS 2 HORIZONTAL 10-27/32" (275.3) 3 SILL 6 3 ELEVATION IS NUMBER KEYED TO DETAILS 7 BUTT HUNG OR OFFSET PIVOT (275.3) 10-27/32" DOOR JAMB © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 HEAD 7/8" (22.2) 2-1/2" (63.5) 4 JAMB 5 VERTICAL INTERMEDIATE 6 DOOR JAMB BUTT HUNG OR OFFSET PIVOT Note: Metal interface uses 3M™ VHB™ SGT (Structural Glazing Tape) kawneer.com ADMD100EN 11 12 Clearwall™ Curtain Wall System CORNER DETAILS OCTOBER, 2015 EC 97911-084 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 90° INSIDE (SS) CORNER 90° OUTSIDE (SS) CORNER Note: 5-1/8" (130.2) System shown, 6-5/8" (168.3) System similar. 90° INSIDE (SSI) CORNER 90° OUTSIDE (SSI) CORNER Note: 6" (152.4) System shown, 7-1/2" (190.5) System similar. 90° INSIDE (SSIT) CORNER 90° OUTSIDE (SSIT) CORNER Note: 5-7/8" (149.2) System shown, 7-3/8" (187.3) System similar. ADMD100EN kawneer.com © Kawneer Company, Inc., 2013 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SCALE 3" = 1'-0" © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. OCTOBER, 2015 EC 97911-084 kawneer.com Clearwall™ Curtain Wall System 90° OUTSIDE SINGLE MULLION CORNER DETAILS SCALE 3" = 1'-0" 90° OUTSIDE (SS) CORNER 5-1/8" (130.2) System 90° OUTSIDE (SSI) CORNER 6" (152.4) System 90° OUTSIDE (SSIT) CORNER 5-7/8" (149.2) System 90° OUTSIDE (SS) CORNER 6-5/8" (168.3) System 90° OUTSIDE (SSI) CORNER 7-1/2" (190.5) System 90° OUTSIDE (SSIT) CORNER 7-3/8" (187.3) System ADMD100EN 13 1" (25.4) MINIMUM ANCHORING TO FLOOR SLAB 1" (25.4) MINIMUM ANCHORING TO SUPPORT STEEL ADMD100EN kawneer.com © Kawneer Company, Inc., 2013 ANCHORING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Clearwall™ Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 14 OCTOBER, 2015 EC 97911-084 Actual project conditions will determine specific anchor design. Details on this page are for reference only. Note: Clearwall 6-5/8" (168.3) Screw Spline (SS) system shown, other Clearwall systems are similar. © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. OCTOBER, 2015 kawneer.com Clearwall™ Curtain Wall System EC 97911-084 ANCHORING Actual project conditions will determine specific anchor design. Details on this page are for reference only. Note: Clearwall 6-5/8" (168.3) Screw Spline (SS) system shown, other Clearwall systems are similar. 1" (25.4) MINIMUM ANCHORING TO HORIZONTAL STRUCTURAL STEEL 1" (25.4) MINIMUM ANCHORING TO VERTICAL STRUCTURAL STEEL ADMD100EN 15 16 Clearwall™ Curtain Wall System WIND LOAD / DEAD LOAD CHARTS OCTOBER, 2015 EC 97911-084 DEADLOAD CHARTS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass or 1-3/4" (44.5) thick glass supported on two setting blocks placed at the loading points shown. ADMD100EN kawneer.com © Kawneer Company, Inc., 2013 Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WIND LOAD CHARTS Clearwall™ Curtain Wall System OCTOBER, 2015 WIND LOAD CHARTS (SCREW SPLINE / TOGGLES AT 6" O/C) EC 97911-084 A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN MULLION CENTERS IN METERS 2.0 TWIN SPAN MULLION CENTERS IN METERS 1.0 20 9.0 28 12 11 10 3.0 9 A 8 B C 7 2.0 D E 6 5 23 7.0 22 21 A 20 6.0 19 18 17 B 5.0 15 4 C 14 1.0 (SS) 172001 0 1 2 3 4 5 6 7 (SS) 172002 13 Combined I = 3.494 (145.43 x 104) Combined S = 1.634 (26.78 x 103) 8 MULLION CENTERS IN FEET 12 0 1 2 3 4 5 MULLION CENTERS IN METERS 2.0 1.0 20 9.0 28 A 11 10 B 9 C 8 D E 3.0 7 2.0 8.0 26 MULLION HEIGHT IN FEET 12 27 A 25 EQUAL 4.0 13 MULLION HEIGHT IN METERS 5.0 MULLION HEIGHT 17 EQUAL 18 MULLION HEIGHT 29 14 2.0 30 6.0 19 15 7 E8 6 TWIN SPAN MULLION CENTERS IN METERS 16 4.0 MULLION CENTERS IN FEET Note: These curves are for 6" (152.4) on center toggles with 1-1/8" (28.6) glass. SINGLE SPAN 1.0 D 24 23 7.0 22 B 21 20 6.0 19 C 18 17 6 16 D 5 15 E 4 14 1.0 3 2 (SS) 172003 (SS) 172004 Combined I = 7.871 (327.61 x 10 ) Combined S = 2.648 (43.39 x 103) 4 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET kawneer.com ADMD100EN 5.0 4.0 13 12 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET MULLION HEIGHT IN METERS 3 MULLION HEIGHT IN FEET 24 16 2 © Kawneer Company, Inc., 2013 8.0 26 MULLION HEIGHT IN FEET 4.0 13 27 25 EQUAL 14 MULLION HEIGHT 15 MULLION HEIGHT IN METERS 5.0 EQUAL 18 MULLION HEIGHT 29 17 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 6.0 19 16 2.0 30 MULLION HEIGHT IN METERS 1.0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 17 Clearwall™ Curtain Wall System OCTOBER, 2015 WIND LOAD CHARTS (SCREW SPLINE / TOGGLES AT 9" O/C) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN MULLION CENTERS IN METERS 2.0 TWIN SPAN MULLION CENTERS IN METERS 1.0 20 6.0 28 12 11 10 3.0 9 A 8 B C 7 8.0 26 25 2.0 6 24 23 7.0 22 21 A 20 6.0 19 18 17 B 5.0 16 D 5 15 E 4 14 1.0 (SS) 172001 2 0 1 2 3 4 5 6 7 (SS) 172002 Combined I = 3.494 (145.43 x 104) Combined S = 1.634 (26.78 x 103) 8 MULLION CENTERS IN FEET 12 0 2 3 MULLION CENTERS IN METERS 1.0 20 9.0 28 A 11 B 10 3.0 9 8 7 C 2.0 8.0 26 MULLION HEIGHT IN FEET 12 27 A 25 EQUAL 4.0 13 MULLION HEIGHT IN METERS 5.0 MULLION HEIGHT 17 EQUAL 18 MULLION HEIGHT 29 14 2.0 30 6.0 19 15 8 TWIN SPAN 2.0 16 4 E 5D 6 C7 MULLION CENTERS IN FEET MULLION CENTERS IN METERS MULLION HEIGHT IN FEET 1 Note: These curves are for 9" (228.6) on center toggles with 1-1/8" (28.6) glass. SINGLE SPAN 1.0 4.0 13 24 23 7.0 22 B 21 20 6.0 19 18 17 MULLION HEIGHT IN METERS 3 5.0 6 16 D 5 15 E 4 14 1.0 3 2 (SS) 172003 (SS) 172004 Combined I = 7.871 (327.61 x 10 ) Combined S = 2.648 (43.39 x 103) 4 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET ADMD100EN 4.0 13 12 0 1 2 3 4 E 5 D 6 C7 8 MULLION CENTERS IN FEET kawneer.com © Kawneer Company, Inc., 2013 4.0 13 27 MULLION HEIGHT IN FEET 14 EQUAL MULLION HEIGHT IN FEET 15 MULLION HEIGHT IN METERS 5.0 MULLION HEIGHT 17 EQUAL 18 MULLION HEIGHT 29 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 9.0 19 16 2.0 30 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1.0 EC 97911-084 MULLION HEIGHT IN METERS 18 Clearwall™ Curtain Wall System OCTOBER, 2015 WIND LOAD CHARTS (SCREW SPLINE INTERFACE / TOGGLES AT 9" O/C) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN MULLION CENTERS IN METERS 2.0 1.0 TWIN SPAN MULLION CENTERS IN METERS 1.0 20 9.0 28 12 11 10 3.0 9 A 8 B C 7 E D 2.0 A 6.0 19 18 17 B (SSI) 172001 1 2 3 4 5 6 7 8 (SSI) 172002 13 Combined I = 3.494 (145.43 x 104) Combined S = 1.634 (26.78 x 103) 12 D 4.0 0 1 2 3 4 5 6 MULLION CENTERS IN METERS 1.0 2.0 30 6.0 19 8 TWIN SPAN 2.0 20 7 MULLION CENTERS IN FEET MULLION CENTERS IN METERS 1.0 E Note: These curves are for 9" (228.6) on center toggles with 1" (25.4) glass. SINGLE SPAN 5.0 C 14 1.0 3 9.0 29 12 A 11 10 B 9 C 3.0 8 7 D 2.0 6 EQUAL 8.0 26 A 25 24 23 7.0 22 B 21 20 6.0 19 18 E C D 17 5.0 16 E 5 27 15 4 14 1.0 3 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET kawneer.com (SSI) 172003 (SSI) 172004 13 Combined I = 7.871 (327.61 x 10 ) Combined S = 2.648 (43.39 x 103) 12 4 ADMD100EN 4.0 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET MULLION HEIGHT IN METERS 4.0 13 28 MULLION HEIGHT IN FEET 14 EQUAL 15 MULLION HEIGHT IN METERS 5.0 16 MULLION HEIGHT 17 MULLION HEIGHT 18 MULLION HEIGHT IN FEET 21 20 15 4 7.0 22 5 MULLION CENTERS IN FEET © Kawneer Company, Inc., 2013 23 16 2 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 24 6 2 8.0 26 MULLION HEIGHT IN FEET 4.0 13 27 25 EQUAL 14 MULLION HEIGHT 15 MULLION HEIGHT IN METERS 5.0 EQUAL 18 MULLION HEIGHT 29 17 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 6.0 19 16 2.0 30 MULLION HEIGHT IN METERS EC 97911-084 0 19 Clearwall™ Curtain Wall System OCTOBER, 2015 WIND LOAD CHARTS (SCREW SPLINE INTERFACE TAPE / TOGGLES AT 9" O/C) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN MULLION CENTERS IN METERS 2.0 TWIN SPAN MULLION CENTERS IN METERS 1.0 20 6.0 28 12 11 10 3.0 9 A 8 B E D 7 C 25 2.0 24 23 7.0 22 21 A 20 6.0 19 18 17 6 16 5 15 4 B E D 5.0 C 14 1.0 (SSIT) 172001 2 0 1 2 3 4 5 6 7 (SSIT) 172002 Combined I = 3.494 (145.43 x 104) Combined S = 1.634 (26.78 x 103) 8 MULLION CENTERS IN FEET 12 0 4 5 6 1.0 A 11 B 10 3.0 C 8 7 2.0 27 8.0 26 MULLION HEIGHT IN FEET 12 2.0 A 25 EQUAL 4.0 13 MULLION HEIGHT 14 MULLION HEIGHT IN METERS 5.0 EQUAL 28 17 MULLION HEIGHT 18 15 8 9.0 29 16 7 30 6.0 19 E D 3 MULLION CENTERS IN METERS 2.0 20 9 2 TWIN SPAN MULLION CENTERS IN METERS 1.0 1 MULLION CENTERS IN FEET Note: These curves are for 9" (228.6) on center toggles with 1" (25.4) glass. SINGLE SPAN 4.0 13 24 23 7.0 22 B 21 E D 20 C 6.0 19 18 17 MULLION HEIGHT IN METERS 3 MULLION HEIGHT IN FEET 8.0 26 5.0 6 16 5 15 4 14 1.0 3 2 (SSIT) 172003 (SSIT) 172004 Combined I = 7.871 (327.61 x 10 ) Combined S = 2.648 (43.39 x 103) 4 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET ADMD100EN 4.0 13 12 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET kawneer.com © Kawneer Company, Inc., 2013 4.0 13 27 MULLION HEIGHT IN FEET 14 EQUAL MULLION HEIGHT IN FEET 15 MULLION HEIGHT IN METERS 5.0 MULLION HEIGHT 17 EQUAL 18 MULLION HEIGHT 29 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 9.0 19 16 2.0 30 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1.0 EC 97911-084 MULLION HEIGHT IN METERS 20 Clearwall™ Curtain Wall System OCTOBER, 2015 WIND LOAD CHARTS (SHEAR BLOCK / TOGGLES AT 6" O/C) EC 97911-084 A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN MULLION CENTERS IN METERS 1.0 2.0 28 SINGLE SPAN MULLION CENTERS IN METERS 1.0 8.5 8.5 27 8 8 7.5 7 23 22 6.5 21 20 6 19 A 18 5.5 17 B 5 16 C 15 4.5 14 D E 13 4 MULLION HEIGHT IN METERS 24 25 MULLION HEIGHT IN FEET 25 MULLION HEIGHT 26 (SB) 172023 W/162363 3.5 I = 37.690 (1568.77 x 104) S = 8.525 (139.70 x 103) 0 1 2 3 4 5 6 7 7 22 B 6.5 21 C 20 6 19 D 5.5 18 E 17 5 16 15 4.5 4 12 3.5 Ia = 37.690 (1568.77 x 104) Sa = 8.525 (139.70 x 103) Is = 17.600 (732.56 x 104) Ss = 4.732 (77.54 x 103) 8 MULLION CENTERS IN FEET 11 10 0 1 2 3 4 5 6 8 SINGLE SPAN MULLION CENTERS IN METERS MULLION CENTERS IN METERS 2.0 1.0 28 7 MULLION CENTERS IN FEET Note: These curves are for 6" (152.4) on center toggles with 1-1/8" (28.6) glass. SINGLE SPAN 1.0 23 13 12 10 A 14 (SB) 172023 11 7.5 24 MULLION HEIGHT IN METERS 26 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2.0 28 27 8.5 28 A 27 2.0 8.5 A 8 7.5 24 7 MULLION HEIGHT IN FEET 23 22 C 6.5 21 D 20 6 19 E 18 5.5 17 5 16 15 4.5 MULLION HEIGHT IN METERS B 25 MULLION HEIGHT IN FEET 25 8 26 MULLION HEIGHT 26 14 7.5 24 B 23 7 C 22 6.5 21 D 20 6 19 E 18 5.5 17 5 16 15 4.5 14 4 13 12 3.5 11 (SB) 172023 W/162363/364/365 0 1 2 3 4 5 6 7 3.5 4 MULLION CENTERS IN FEET kawneer.com 12 11 Ia = 37.690 (1568.77 x 10 ) Ia = 37.690 (1568.77 x 10 ) Sa = 8.525 (139.70 x 103) Sa = 8.525 (139.70 x 103) 10 4 4 8 Combined Is = 26.033 (1083.57 x 10 ) Combined Is = 32.432 (1349.92 x 10 ) 0 Combined Ss = 7.000 (114.71 x 103) Combined Ss = 8.721 (142.91 x 103) 4 10 4 13 (SB) 172023 W/162363/364 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET ADMD100EN MULLION HEIGHT IN METERS 27 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 21 Clearwall™ Curtain Wall System 22 OCTOBER, 2015 WIND LOAD CHARTS (SHEAR BLOCK / TOGGLES AT 9" O/C) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN MULLION CENTERS IN METERS 1.0 2.0 28 EC 97911-084 SINGLE SPAN MULLION CENTERS IN METERS 1.0 8.5 27 8 20 6 19 A 18 5.5 17 B 5 16 15 4.5 14 A 23 7 22 B 6.5 21 20 6 19 5.5 18 17 5 16 15 4.5 14 4 12 (SB) 172023 W/162363 3.5 11 I = 37.690 (1568.77 x 104) S = 8.525 (139.70 x 103) 10 0 1 2 3 4 E 5 D 6 C7 8 MULLION CENTERS IN FEET 12 3.5 Ia = 37.690 (1568.77 x 104) Sa = 8.525 (139.70 x 103) Is = 17.600 (732.56 x 104) Ss = 4.732 (77.54 x 103) 11 10 0 1 2 3 MULLION CENTERS IN METERS 2.0 1.0 A 24 23 22 6.5 21 20 6 19 5.5 18 17 5 16 15 4.5 MULLION HEIGHT IN METERS B 25 7.5 MULLION HEIGHT IN FEET 7.5 7 A 8 26 MULLION HEIGHT 25 8.5 27 8 26 2.0 28 8.5 27 8 SINGLE SPAN MULLION CENTERS IN METERS 28 4 E 5 D 6 C7 MULLION CENTERS IN FEET Note: These curves are for 9" (228.6) on center toggles with 1-1/8" (28.6) glass. SINGLE SPAN 1.0 4 13 (SB) 172023 24 B 23 7 22 6.5 21 20 6 19 18 5.5 17 5 16 15 4.5 MULLION HEIGHT IN METERS 13 14 14 4 13 12 3.5 11 10 0 1 2 3 4 E 5 D 6 C7 4 13 (SB) 172023 W/162363/364 (SB) 172023 W/162363/364/365 12 3.5 11 Ia = 37.690 (1568.77 x 104) Ia = 37.690 (1568.77 x 104) Sa = 8.525 (139.70 x 103) Sa = 8.525 (139.70 x 103) 10 4 4 8 Combined Is = 26.033 (1083.57 x 10 ) Combined Is = 32.432 (1349.92 x 10 ) 0 3 3 Combined Ss = 7.000 (114.71 x 10 ) Combined Ss = 8.721 (142.91 x 10 ) MULLION CENTERS IN FEET 1 2 3 4 E 5 D 6 C7 8 MULLION CENTERS IN FEET ADMD100EN kawneer.com © Kawneer Company, Inc., 2013 6.5 21 7.5 24 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 22 MULLION HEIGHT IN METERS 7 23 25 MULLION HEIGHT IN FEET 7.5 24 MULLION HEIGHT IN METERS MULLION HEIGHT 26 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 8 25 MULLION HEIGHT IN FEET 8.5 27 26 MULLION HEIGHT IN FEET 2.0 28 Clearwall™ Curtain Wall System OCTOBER, 2015 WIND LOAD CHARTS (SHEAR BLOCK INTERFACE / TOGGLES AT 9" O/C) EC 97911-084 A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN MULLION CENTERS IN METERS 1.0 2.0 28 SINGLE SPAN MULLION CENTERS IN METERS 1.0 8.5 8 22 6.5 21 20 6 19 A 5.5 18 17 B 5 16 D E C 4.5 15 MULLION HEIGHT IN METERS 7 23 25 MULLION HEIGHT IN FEET 7.5 24 14 7.5 24 A 23 7 22 B 6.5 21 C 20 6 D 19 E 5.5 18 17 5 16 15 4.5 MULLION HEIGHT IN METERS MULLION HEIGHT 25 14 4 (SBI) 172023 12 3.5 11 I = 37.690 (1568.77 x 104) S = 8.525 (139.70 x 103) 0 1 2 3 4 5 6 7 12 3.5 Ia = 37.690 (1568.77 x 104) Sa = 8.525 (139.70 x 103) Is = 17.600 (732.56 x 104) Ss = 4.732 (77.54 x 103) 8 MULLION CENTERS IN FEET 11 10 0 1 2 5 6 1.0 28 27 8.5 28 A 27 8 7.5 24 7 C D 6.5 E 20 6 19 5.5 18 17 5 16 15 4.5 MULLION HEIGHT IN METERS B 23 2.0 8.5 A 8 25 7.5 B 24 23 MULLION HEIGHT IN FEET 25 8 26 MULLION HEIGHT 26 7 MULLION CENTERS IN METERS 2.0 21 4 SINGLE SPAN MULLION CENTERS IN METERS 22 3 MULLION CENTERS IN FEET Note: These curves are for 9" (228.6) on center toggles with 1" (25.4) glass. SINGLE SPAN 1.0 4 13 (SBI) 172023 W/162363 7 D E C 22 6.5 21 20 6 19 5.5 18 17 5 16 15 4.5 14 14 4 13 12 3.5 11 (SBI) 172023 W/162363/364/365 0 1 2 3 4 5 6 7 3.5 4 MULLION CENTERS IN FEET kawneer.com 12 11 Ia = 37.690 (1568.77 x 10 ) Ia = 37.690 (1568.77 x 10 ) Sa = 8.525 (139.70 x 103) Sa = 8.525 (139.70 x 103) 10 4 4 0 8 Combined Is = 26.033 (1083.57 x 10 ) Combined Is = 32.432 (1349.92 x 10 ) 3 3 Combined Ss = 7.000 (114.71 x 10 ) Combined Ss = 8.721 (142.91 x 10 ) 4 10 4 13 (SBI) 172023 W/162363/364 ADMD100EN 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET MULLION HEIGHT IN METERS 13 MULLION HEIGHT IN FEET 8 26 10 © Kawneer Company, Inc., 2013 8.5 27 26 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2.0 28 27 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 23 Clearwall™ Curtain Wall System 24 OCTOBER, 2015 WIND LOAD CHARTS (SHEAR BLOCK INTERFACE TAPE / TOGGLES AT 9" O/C) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN MULLION CENTERS IN METERS 1.0 2.0 28 8.5 SINGLE SPAN MULLION CENTERS IN METERS 1.0 8.5 8 8 20 6 19 A 18 5.5 B 17 5 16 C 15 4.5 D 14 4 12 (SBIT) 172023 W/162363 3.5 11 I = 37.690 (1568.77 x 104) S = 8.525 (139.70 x 103) 1 2 3 4 7 22 B 6.5 21 C 20 6 D 19 5.5 18 E 17 5 16 15 4.5 5 6 7 8 MULLION CENTERS IN FEET 12 3.5 Ia = 37.690 (1568.77 x 104) Sa = 8.525 (139.70 x 103) Is = 17.600 (732.56 x 104) Ss = 4.732 (77.54 x 103) 11 10 0 1 2 3 4 5 6 8 SINGLE SPAN MULLION CENTERS IN METERS MULLION CENTERS IN METERS 2.0 1.0 28 7 MULLION CENTERS IN FEET Note: These curves are for 9" (228.6) on center toggles with 1" (25.4) glass. SINGLE SPAN 1.0 4 13 (SBIT) 172023 0 23 14 E 13 A 8.5 28 A 27 2.0 8.5 A 8 7.5 24 7 C 22 D 6.5 21 20 6 E 19 5.5 18 17 5 16 15 4.5 MULLION HEIGHT IN METERS B 23 MULLION HEIGHT IN FEET 26 25 7.5 B 24 C 7 23 MULLION HEIGHT IN FEET 25 MULLION HEIGHT 26 8 14 D 22 E 6.5 21 20 6 19 5.5 18 17 5 16 15 4.5 MULLION HEIGHT IN METERS 27 14 4 13 12 3.5 11 (SBIT) 172023 W/162363/364/365 0 1 2 3 4 5 6 7 12 3.5 11 Ia = 37.690 (1568.77 x 10 ) Ia = 37.690 (1568.77 x 10 ) Sa = 8.525 (139.70 x 103) Sa = 8.525 (139.70 x 103) 10 4 4 8 Combined Is = 26.033 (1083.57 x 10 ) Combined Is = 32.432 (1349.92 x 10 ) 0 Combined Ss = 7.000 (114.71 x 103) Combined Ss = 8.721 (142.91 x 103) 4 10 4 13 (SBIT) 172023 W/162363/364 4 MULLION CENTERS IN FEET 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET ADMD100EN kawneer.com © Kawneer Company, Inc., 2013 6.5 21 7.5 24 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 7 22 MULLION HEIGHT IN METERS 23 25 MULLION HEIGHT IN METERS 7.5 24 MULLION HEIGHT IN FEET 25 MULLION HEIGHT 26 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 27 26 MULLION HEIGHT IN FEET 2.0 28 27 10 EC 97911-084 Clearwall™ Curtain Wall System OCTOBER, 2015 DEAD LOAD CHARTS EC 97911-084 GLASS TYPE AND LOADING: NOTE: DASHED LINE REPRESENTS A 45 SQ/FT ALLOWABLE MAXIMUM GLASS LIMIT FOR A 4-1/2" LONG GLASS CHAIR. GLASS SIZES ABOVE THIS LINE REQUIRE THE GLASS CHAIR AND SETTING BLOCK TO BE DOUBLED UP (SIDE BY SIDE) AT POINTS REQUIRED. (1" or 1-1/8" INFILL) (1" or 1-1/8" INFILL) SPAN IN METERS SPAN IN METERS 2.0 1.0 * 12 2.0 6 C 5 * 4 B 1.0 3 A 2 172007 I = 1.601 (66.64 x 104) S = 1.281 (20.99 x 103) * 7 2.0 6 * 5 4 1.0 3 C B A 1 0 1 2 3 4 5 6 7 0 172008 8 I = 0.570 (23.73 x 10 ) S = 0.428 (7.02 x 103) 4 0 1 2 3 4 5 6 7 8 SPAN IN FEET (1" or 1-1/8" INFILL) (1" or 1-1/8" INFILL) SPAN IN METERS SPAN IN METERS 2.0 1.0 * 12 2.0 1.0 * 12 11 * 8 C 7 2.0 6 5 * B 4 A 1.0 3 2 10 172009 I = 2.033 (84.62 x 104) S = 1.627 (26.66 x 103) 3.0 9 8 * 7 2.0 6 * 5 4 1.0 3 C B A 2 1 1 0 1 2 3 4 5 6 SPAN IN FEET kawneer.com 7 8 172010 I = 0.581 (24.18 x 104) S = 0.446 (7.31 x 103) ADMD100EN 0 0 1 2 3 4 5 6 SPAN IN FEET 7 8 GLASS HEIGHT IN METERS 9 GLASS HEIGHT IN FEET 3.0 GLASS HEIGHT IN METERS 11 10 GLASS HEIGHT IN FEET 8 2 SPAN IN FEET © Kawneer Company, Inc., 2013 3.0 9 GLASS HEIGHT IN METERS 7 10 GLASS HEIGHT IN FEET * 8 GLASS HEIGHT IN METERS 3.0 9 1 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. * 11 10 0 2.0 1.0 12 11 GLASS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 1" OR 1-1/8" GLASS - 1/4 POINT LOADING B = 1" OR 1-1/8" GLASS - 1/6 POINT LOADING C = 1" OR 1-1/8" GLASS - 1/8 POINT LOADING 0 25 Clearwall™ Curtain Wall System 26 OCTOBER, 2015 THERMAL CHARTS EC 97911-084 Project Specific U-factor Example Calculation (Based on single bay of Curtain Wall/Window Wall) VISION 6'-0" D.L.O. SPANDREL 9'-0" D.L.O. VISION Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 5'-0" D.L.O. Vision Area Example Glass U-factor = 0.48 Btu/(ft2 · h · °F) Vision Area = 5(9 + 8 + 4) = 105.0 ft2 Total Area (Vision) = 5' 2-1/2" (9' 3-3/4" + 8' 2-1/2" + 4' 2-1/2") = 113.2 ft2 Percentage of Vision Glass = (Vision Area ÷ Total Area)100 = (105.0 ÷ 113.2)100 = 93% Spandrel Area Example Spandrel R-value = 15 (ft2 · h · °F)/Btu Spandrel Area = 5(6 + 3) = 45.0 ft2 Total Area (Spandrel) = 5' 2-1/2" (6' 2-1/2" + 3' 3-3/4") = 49.6 ft2 Percent of Spandrel = (Spandrel Area ÷ Total Area)100 = (49.0 ÷ 49.6)100 = 91% ADMD100EN kawneer.com © Kawneer Company, Inc., 2013 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. VISION 2-1/2" Typ. SPANDREL 31'-3" 8'-0" D.L.O. 4'-0" 3'-0" D.L.O. D.L.O. 2-1/2" Typ. Clearwall™ Curtain Wall System OCTOBER, 2015 27 THERMAL CHARTS EC 97911-084 Vision Area Chart System U-factor vs Percent of Vision Area 0.80 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. T COG U-factor 0.53 0.50 0.40 0.30 ) 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.60 Btu h·ft 2·°F System U-factor O E IGN PL S M E A D EX FOR (N 0.70 93% 0.20 95 85 90 75 80 70 Vision Area / Total Area (%) Based on a single curtain wall bay of 93% vision glass and center of glass U-factor of 0.48, System U-factor is equal to 0.53 Btu/(h·ft 2·°F) System U-factor vs Percent of Spandrel Area Spandrel R-value E IGN PL S M E A D EX FOR O 0.50 T 3.00 4.00 © Kawneer Company, Inc., 2013 5.00 0.21 0.20 0.10 91% 95 0.30 ) 11.00 15.00 19.00 30.00 0.40 Btu h·ft 2·°F System U-factor 2.00 0.60 (N Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Spandrel Area Chart 90 85 80 75 70 Spandrel Area / Total Area (%) Based on a single curtain wall bay of 91% spandrel and center of spandrel R-value of 15, system U-factor is equal to 0.21 Btu/(h·ft 2·°F) kawneer.com ADMD100EN Clearwall™ Curtain Wall System OCTOBER, 2015 THERMAL CHARTS - SS EC 97911-084 Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. 0.65 0.60 (3.50) COG U-factor 0.50 0.48 (2.73) 0.46 (2.61) 0.44 (2.50) 0.45 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.40 0.36 (2.05) (3.00) (2.50) System U-Factor (W/m2·°C) 0.55 0.34 (1.93) 0.32 (1.82) 0.35 (2.00) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.30 0.24 (1.37) 0.22 (1.25) 0.25 0.20 (1.14) (1.50) 0.20 Vision Area / Total Area (%) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. ADMD100EN kawneer.com © Kawneer Company, Inc., 2013 (4.00) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.70 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-Factor for Vision Glass System U-Factor (Btu/h·ft2·°F) 28 System VT © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. OCTOBER, 2015 kawneer.com Clearwall™ Curtain Wall System EC 97911-084 Vision Ares / Total Area (%) Charts are generated per AAMA 507. ADMD100EN 29 THERMAL CHARTS - SS System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) Charts are generated per AAMA 507. System Visible Transmittance (VT) vs Percent of Vision Area COG VT Clearwall™ Curtain Wall System OCTOBER, 2015 THERMAL PERFORMANCE MATRIX (NFRC SIZE) - SS EC 97911-084 Overall U-Factor 4 0.48 0.54 0.46 0.53 0.44 0.51 0.42 0.50 0.40 0.48 0.38 0.46 0.36 0.45 0.34 0.43 0.32 0.41 0.30 0.40 0.28 0.38 0.26 0.37 0.24 0.35 0.22 0.33 0.20 0.32 SHGC Matrix 2 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.74 0.75 0.67 0.70 0.70 0.70 0.62 0.65 0.66 0.65 0.58 0.60 0.61 0.60 0.53 0.55 0.57 0.55 0.49 0.50 0.52 0.50 0.44 0.45 0.48 0.45 0.40 0.40 0.43 0.40 0.35 0.35 0.39 0.35 0.31 0.30 0.35 0.30 0.27 0.25 0.30 0.25 0.22 0.20 0.26 0.20 0.18 0.15 0.21 0.15 0.13 0.10 0.17 0.10 0.09 0.05 0.12 0.05 0.04 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200. 3. Glass properties are based on center of glass values and are obtained from your glass supplier. 4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). ADMD100EN kawneer.com © Kawneer Company, Inc., 2013 Glass U-Factor 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 30 Clearwall™ Curtain Wall System OCTOBER, 2015 31 THERMAL CHARTS - SSI EC 97911-084 Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-Factor for Vision Glass 0.70 (4.00) 0.65 0.60 0.50 0.48 (2.73) 0.44 (2.50) 0.45 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.40 0.36 (2.05) (3.00) (2.50) 0.34 (1.93) 0.32 (1.82) 0.35 (2.00) 0.30 (1.71) 0.28 (1.59) 0.30 0.26 (1.48) © Kawneer Company, Inc., 2013 0.24 (1.37) 0.22 (1.25) 0.25 0.20 (1.14) 0.20 Vision Area / Total Area (%) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. kawneer.com ADMD100EN (1.50) System U-Factor (W/m2·°C) COG U-factor System U-Factor (Btu/h·ft2·°F) 0.55 0.46 (2.61) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. (3.50) COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT Vision Ares / Total Area (%) Charts are generated per AAMA 507. ADMD100EN kawneer.com © Kawneer Company, Inc., 2013 THERMAL CHARTS - SSI Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC Clearwall™ Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 32 OCTOBER, 2015 EC 97911-084 System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area Charts are generated per AAMA 507. Clearwall™ Curtain Wall System OCTOBER, 2015 THERMAL PERFORMANCE MATRIX (NFRC SIZE) - SSI EC 97911-084 Glass U-Factor 3 Overall U-Factor 4 0.48 0.53 0.46 0.51 0.44 0.49 0.42 0.47 0.40 0.46 0.38 0.44 0.36 0.42 0.34 0.41 0.32 0.39 0.30 0.37 0.28 0.35 0.26 0.34 0.24 0.32 0.22 0.30 0.20 0.29 SHGC Matrix 2 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.73 0.75 0.68 0.70 0.69 0.70 0.63 0.65 0.64 0.65 0.59 0.60 0.60 0.60 0.54 0.55 0.55 0.55 0.50 0.50 0.50 0.50 0.45 0.45 0.46 0.45 0.41 0.40 0.41 0.40 0.36 0.35 0.37 0.35 0.32 0.30 0.32 0.30 0.27 0.25 0.28 0.25 0.23 0.20 0.23 0.20 0.18 0.15 0.19 0.15 0.14 0.10 0.14 0.10 0.09 0.05 0.10 0.05 0.05 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Thermal Transmittance 1 (BTU/hr • ft 2 • °F) NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200. 3. Glass properties are based on center of glass values and are obtained from your glass supplier. 4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). kawneer.com ADMD100EN 33 Clearwall™ Curtain Wall System OCTOBER, 2015 THERMAL CHARTS - SSIT EC 97911-084 (3.50) 0.55 (3.00) 0.50 COG U-factor 0.46 (2.61) 0.45 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.40 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.35 0.32 (1.82) (2.50) System U-Factor (W/m2·°C) 0.48 (2.73) (2.00) 0.30 (1.71) 0.30 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.25 0.22 (1.25) (1.50) 0.20 (1.14) 0.20 Vision Area / Total Area (%) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. ADMD100EN kawneer.com © Kawneer Company, Inc., 2013 0.60 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System U-Factor for Vision Glass Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. System U-Factor (Btu/h·ft2·°F) 34 System VT © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. OCTOBER, 2015 kawneer.com Clearwall™ Curtain Wall System EC 97911-084 Vision Ares / Total Area (%) Charts are generated per AAMA 507. ADMD100EN 35 THERMAL CHARTS - SSIT System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) Charts are generated per AAMA 507. System Visible Transmittance (VT) vs Percent of Vision Area COG VT Clearwall™ Curtain Wall System OCTOBER, 2015 THERMAL PERFORMANCE MATRIX (NFRC SIZE) - SSIT EC 97911-084 Overall U-Factor 4 0.48 0.50 0.46 0.48 0.44 0.46 0.42 0.45 0.40 0.43 0.38 0.41 0.36 0.40 0.34 0.38 0.32 0.36 0.30 0.35 0.28 0.33 0.26 0.31 0.24 0.30 0.22 0.28 0.20 0.26 SHGC Matrix 2 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.71 0.75 0.68 0.70 0.67 0.70 0.63 0.65 0.62 0.65 0.59 0.60 0.58 0.60 0.54 0.55 0.53 0.55 0.50 0.50 0.49 0.50 0.45 0.45 0.44 0.45 0.41 0.40 0.40 0.40 0.36 0.35 0.35 0.35 0.32 0.30 0.31 0.30 0.27 0.25 0.26 0.25 0.23 0.20 0.22 0.20 0.18 0.15 0.17 0.15 0.14 0.10 0.12 0.10 0.09 0.05 0.08 0.05 0.05 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200. 3. Glass properties are based on center of glass values and are obtained from your glass supplier. 4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). ADMD100EN kawneer.com © Kawneer Company, Inc., 2013 Glass U-Factor 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 36 Clearwall™ Curtain Wall System OCTOBER, 2015 37 THERMAL CHARTS - SB EC 97911-084 Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-Factor for Vision Glass 0.85 (5.00) 0.80 0.70 (4.00) 0.65 0.60 0.46 (2.61) 0.44 (2.50) 0.45 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.40 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.35 0.30 (1.71) (3.00) (2.50) (2.00) 0.28 (1.59) 0.26 (1.48) 0.30 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.25 (1.50) 0.18 (1.03) 0.16 (0.91) 0.20 © Kawneer Company, Inc., 2013 0.14 (0.80) 0.12 (0.69) (1.00) 0.10 (0.57) 0.15 0.10 Vision Area / Total Area (%) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. kawneer.com ADMD100EN (0.50) System U-Factor (W/m2·°C) 0.50 0.47 (2.67) (3.50) System U-Factor (Btu/h·ft2·°F) 0.55 COG U-factor Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. (4.50) 0.75 Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT Vision Ares / Total Area (%) Charts are generated per AAMA 507. ADMD100EN kawneer.com © Kawneer Company, Inc., 2013 THERMAL CHARTS - SB Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC Clearwall™ Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 38 OCTOBER, 2015 EC 97911-084 System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Charts are generated per AAMA 507. Clearwall™ Curtain Wall System OCTOBER, 2015 39 THERMAL PERFORMANCE MATRIX (NFRC SIZE) - SB EC 97911-084 Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.47 0.55 0.46 0.54 0.44 0.52 0.42 0.51 0.40 0.49 0.38 0.47 0.36 0.46 0.34 0.44 0.32 0.42 0.30 0.41 0.28 0.39 0.26 0.38 0.24 0.36 0.22 0.34 0.20 0.32 0.18 0.31 0.16 0.29 0.14 0.28 0.12 0.26 0.10 0.25 NOTE: For glass values that are not listed, linear interpolation is permitted. 1.U-Factors are determined in accordance with NFRC 100. 2.SHGC and VT values are determined in accordance with NFRC 200. 3.Glass properties are based on center of glass values and are obtained from your glass supplier. 4.Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). SHGC Matrix 2 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.75 0.75 0.67 0.70 0.71 0.70 0.62 0.65 0.66 0.65 0.58 0.60 0.62 0.60 0.53 0.55 0.57 0.55 0.49 0.50 0.53 0.50 0.44 0.45 0.49 0.45 0.40 0.40 0.44 0.40 0.36 0.35 0.40 0.35 0.31 0.30 0.35 0.30 0.27 0.25 0.31 0.25 0.22 0.20 0.26 0.20 0.18 0.15 0.22 0.15 0.13 0.10 0.17 0.10 0.09 0.05 0.13 0.05 0.04 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com ADMD100EN Clearwall™ Curtain Wall System OCTOBER, 2015 THERMAL CHARTS - SBI EC 97911-084 (5.00) 0.80 (4.50) 0.75 0.70 (4.00) 0.65 0.60 COG U-factor 0.50 0.47 (2.67) 0.46 (2.61) 0.44 (2.50) 0.45 0.42 (2.39) 0.40 (2.27) 0.40 0.38 (2.16) 0.36 (2.05) (3.00) (2.50) System U-Factor (W/m2·°C) 0.55 (3.50) 0.34 (1.93) 0.35 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) (2.00) 0.30 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.25 0.20 (1.14) (1.50) 0.18 (1.03) 0.16 (0.91) 0.20 0.14 (0.80) (1.00) 0.12 (0.69) 0.10 (0.57) 0.15 0.10 (0.50) Vision Area / Total Area (%) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. ADMD100EN kawneer.com © Kawneer Company, Inc., 2013 0.85 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System U-Factor for Vision Glass Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. System U-Factor (Btu/h·ft2·°F) 40 System VT © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. OCTOBER, 2015 kawneer.com Clearwall™ Curtain Wall System EC 97911-084 Vision Ares / Total Area (%) Charts are generated per AAMA 507. ADMD100EN 41 THERMAL CHARTS - SSI System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) Charts are generated per AAMA 507. System Visible Transmittance (VT) vs Percent of Vision Area COG VT Clearwall™ Curtain Wall System OCTOBER, 2015 THERMAL PERFORMANCE MATRIX (NFRC SIZE) - SBI EC 97911-084 Overall U-Factor 4 0.47 0.52 0.46 0.51 0.44 0.49 0.42 0.48 0.40 0.46 0.38 0.44 0.36 0.43 0.34 0.41 0.32 0.39 0.30 0.37 0.28 0.36 0.26 0.34 0.24 0.32 0.22 0.31 0.20 0.29 0.18 0.27 0.16 0.26 0.14 0.24 0.12 0.22 0.10 0.20 NOTE: For glass values that are not listed, linear interpolation is permitted. 1.U-Factors are determined in accordance with NFRC 100. 2.SHGC and VT values are determined in accordance with NFRC 200. 3.Glass properties are based on center of glass values and are obtained from your glass supplier. 4.Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). SHGC Matrix 2 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.73 0.75 0.68 0.70 0.69 0.70 0.63 0.65 0.64 0.65 0.59 0.60 0.60 0.60 0.54 0.55 0.55 0.55 0.50 0.50 0.51 0.50 0.45 0.45 0.46 0.45 0.41 0.40 0.41 0.40 0.36 0.35 0.37 0.35 0.32 0.30 0.32 0.30 0.27 0.25 0.28 0.25 0.23 0.20 0.23 0.20 0.18 0.15 0.19 0.15 0.14 0.10 0.14 0.10 0.09 0.05 0.10 0.05 0.05 ADMD100EN kawneer.com © Kawneer Company, Inc., 2013 Glass U-Factor 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 42 Clearwall™ Curtain Wall System OCTOBER, 2015 43 THERMAL CHARTS - SBIT EC 97911-084 Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-Factor for Vision Glass 0.85 (5.00) 0.80 0.70 (4.00) 0.65 0.60 0.47 (2.67) 0.46 (2.61) 0.45 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.40 0.38 (2.16) 0.36 (2.05) 0.35 0.34 (1.93) 0.32 (1.82) (3.00) (2.50) (2.00) 0.30 (1.71) 0.30 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.25 0.22 (1.25) (1.50) 0.20 (1.14) © Kawneer Company, Inc., 2013 0.18 (1.03) 0.20 0.16 (0.91) 0.14 (0.80) (1.00) 0.12 (0.69) 0.15 0.10 (0.57) 0.10 Vision Area / Total Area (%) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. kawneer.com ADMD100EN (0.50) System U-Factor (W/m2·°C) 0.50 (3.50) System U-Factor (Btu/h·ft2·°F) 0.55 COG U-factor Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. (4.50) 0.75 Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT Vision Ares / Total Area (%) Charts are generated per AAMA 507. ADMD100EN kawneer.com © Kawneer Company, Inc., 2013 THERMAL CHARTS - SBIT Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC Clearwall™ Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 44 OCTOBER, 2015 EC 97911-084 System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Charts are generated per AAMA 507. Clearwall™ Curtain Wall System OCTOBER, 2015 45 THERMAL PERFORMANCE MATRIX (NFRC SIZE) - SBIT EC 97911-084 Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.47 0.49 0.46 0.48 0.44 0.46 0.42 0.45 0.40 0.43 0.38 0.41 0.36 0.40 0.34 0.38 0.32 0.36 0.30 0.35 0.28 0.33 0.26 0.31 0.24 0.29 0.22 0.28 0.20 0.26 0.18 0.25 0.16 0.23 0.14 0.21 0.12 0.19 0.10 0.18 NOTE: For glass values that are not listed, linear interpolation is permitted. 1.U-Factors are determined in accordance with NFRC 100. 2.SHGC and VT values are determined in accordance with NFRC 200. 3.Glass properties are based on center of glass values and are obtained from your glass supplier. 4.Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). SHGC Matrix 2 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.71 0.75 0.68 0.70 0.67 0.70 0.63 0.65 0.62 0.65 0.59 0.60 0.58 0.60 0.54 0.55 0.53 0.55 0.50 0.50 0.49 0.50 0.45 0.45 0.44 0.45 0.41 0.40 0.40 0.40 0.36 0.35 0.35 0.35 0.32 0.30 0.31 0.30 0.27 0.25 0.26 0.25 0.23 0.20 0.22 0.20 0.18 0.15 0.17 0.15 0.14 0.10 0.12 0.10 0.09 0.05 0.08 0.05 0.05 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com ADMD100EN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Clearwall™ Curtain Wall System BLANK PAGE ADMD100EN kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 46 OCTOBER, 2015 EC 97911-084