Product Headline 1620/1620 SSG Curtain Wall System ® Description See Less So You Can See More caption It’s hard to say whether the beauty of the 1620/1620 SSG (structural silicone glazed) Curtain Wall System is in the slim, sleek 2" sightline or in the performance. Built on the strength and reliability of the flagship 1600 curtain wall platform, the 1620/1620 SSG Curtain Wall System is an excellent choice for low- to mid-rise applications. The 1620/1620 SSG Curtain Wall System is engineered with a thermal break and can accommodate double pane insulating glass. Helping architects and glazing contractors achieve even greater thermal performance is an optional fiberglass pressure plate. Glaziers and installers can leverage their previous knowledge of 1600 Wall System™1 and 1600 Wall System™2 Curtain Wall to simplify installation. With a slimmed-down sightline and design features that have been tested to U.S. and Canadian standards, the 1620/1620 SSG Curtain Wall System allows you to see more. Economy Performance Test Standards The highly versatile 1620/1620 SSG Curtain Wall System leads the way to performance at a competitive price, providing an attractive, cost-effective solution for low- and mid-rise construction. It allows building owners, architects and glaziers to meet stringent building codes while simultaneously providing fast installation, simplified fabrication, robust design options and value. The 1620 / 1620 SSG Curtain Wall Systems has been tested in accordance with the following major standards for curtain walls: Performance and Aesthetics The 1620/1620 SSG Curtain Wall System delivers the desired narrow sightline aesthetic of many traditional storefront products packaged with performance levels and options expected of a curtain wall system. The system is tested in accordance with North American performance standards for curtain walls, including air and water infiltration, thermal transmittance, severe wind-driven rain, acoustical, and condensation resistance. The stick-fabricated, pressure-glazed curtain wall system is available as a four-sided captured system and offers a vertical SSG mullion option. Additionally, to create flush and unbroken sightlines, the captured and SSG options both use concealed fasteners in their joinery construction. Air Infiltration ASTM E283; NFRC 400; TAS 202 Water ASTM E547, E331; TAS 202 Severe Wind-Driven Rain, Level 10 AAMA 520 Structural – Uniform Wind Load ASTM E330; TAS 202 Thermal Transmittance – U-Factor AAMA 1503, 507; NFRC 100 Condensation Resistance (CRF, I, CR) AAMA 1503; CSA A440.2; NFRC 500 Overall Solar Heat Gain (SHGC, VT) AAMA 507; NFRC 200 Acoustical (STC & OITC) ASTM E90, E1425; AAMA 1801 *Test results available from Kawneer. Contact your Kawneer sales representative for more information. Fabrication and Installation A variety of features enhance ease of installation and minimize time for the 1620/1620 SSG Curtain Wall System, including: • Installers can leverage their knowledge of fabrication and installation methods for the 1600 curtain wall platform. • Straight cuts without notching simplify fabrication. • A pre-engineered rain screen pressure-equalized (RSPE) back pan option is available that uses easy-to-install spandrel adapters. For the Finishing Touch Permanodic™ anodized finishes are available in clear (Class I and Class II) and color (Class I) choices, including champagne, black, light bronze, medium bronze and dark bronze. Painted finishes, including fluoropolymers that meet or exceed the standards of AAMA 2605, are offered in many standard choices and an unlimited number of specially designed colors. Solvent-free powder coatings add the “green” element with high performance, durability and scratch resistance that meet the standards of AAMA 2604. 1620 Curtain Wall Kawneer Company, Inc. Technology Park / Atlanta 555 Guthridge Court Norcross, GA 30092 1620 SSG Curtain Wall kawneer.com kawneergreen.com 770 . 449 . 5555 © Kawneer Company, Inc. 2014 LITHO IN U.S.A. Form No. 14-2188 1600 Wall System™1, 1600 Wall System™2 and Permanodic™ are trademarks of Kawneer Company, Inc. and Alcoa Inc. 1620 SSG Curtain Wall System JUNE, 2015 FEATURES Features • 1620 SSG is an outside glazed structurally silicone glazed curtain wall • 1620 SSG has a 2" (50.8) sight line • Standard 6" (152.4) or 7-1/2" (190.5) depth systems • Standard infill options 1/4" (6.4) and 1" (25.4) • Thermally Broken by means of a continuous 1/4" (6.4) low conductance spacer • Concealed fastener joinery creates smooth, monolithic appearance • Open-back horizontals and perimeters are available for cost savings • Shear block fabrication method • Corner mullions available • Offers integrated entrance framing systems • Silicone compatible glazing materials for long-lasting seals • Two color option • PermanodicTM anodized finishes in seven choices • Painted finishes in standard and custom choices Optional Features • Steel reinforcing available • Rain screen and backpans • Deep covers available • Fiberglass pressure plates available • Heavy-weight mullions available • Profit$MakerTM plus die sets available Product Applications • Ideal for low to mid-rise applications where high performance is desired © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 For specific product applications, Consult your Kawneer representative. kawneer.com ADMD211 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1620 SSG Curtain Wall System BLANK PAGE ADMD211 kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 JUNE, 2015 EC 97911-075 JUNE, 2015 1620 SSG Curtain Wall System EC 97911-075 3 INDEX Architects - Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. PICTORIAL VIEW................................................................................ 5 1" & 1/4" INFILL DETAILS.................................................................. 6 ENTRANCE DETAILS......................................................................... 7 CORNERS............................................................................................ 8 BACKPAN AND MISCELLANEOUS DETAILS................................... 9 MISCELLANEOUS FRAMING........................................................... 10 ANCHORING................................................................................ 11,12 WIND LOAD CHARTS.................................................................. 13-20 DEADLOAD CHARTS.................................................................. 21-22 THERMAL CHARTS .................................................................... 23-30 The following metric (SI ) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADMD211 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1620 SSG Curtain Wall System BLANK PAGE ADMD211 kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 JUNE, 2015 EC 97911-075 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2015 kawneer.com 1620 SSG Curtain Wall System EC 97911-075 PICTORIAL VIEW ADMD211 5 9A 7 3 1 4 7 1A 8 8A 8 6 6A ELEVATION IS NUMBER KEYED TO DETAILS 9 6A ADMD211 7-1/2" (190.5) 6" (152.4) 2 3 8A 4 HEAVY VERTICAL MULLION 5 9B 6 kawneer.com © Kawneer Company, Inc., 2014 1" & 1/4" INFILL DETAILS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1620 SSG Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 9 9A 9B 2" (50.8) 5 5-1/4" (133.4) 2 3-3/4" (95.3) 6 JUNE, 2015 EC 97911-075 SCALE 3" = 1'-0" 1 1A 2" (50.8) 1620 SSG Curtain Wall System JUNE, 2015 EC 97911-075 7 ENTRANCE DETAILS (1" INFILL) 3 2 5 4 1 6 TRANSOM BAR B/H OR O/P C/H BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER OR FLOOR CLOSER B/H OR O/P ELEVATION IS NUMBER KEYED TO DETAILS 2" (50.8) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 1A 2" (50.8) SCALE 3" = 1'-0" 1A DOOR JAMB 2 BUTT HUNG OR OFFSET PIVOT TRANSOM BAR 2" (50.8) 7/8" (22.2) TYP. 4 3 DOOR JAMB CENTER HUNG TRANSOM BAR 6 2-1/2" (63.5) CENTER HUNG CONCEALED OVERHEAD OR FLOOR CLOSER © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. BUTT HUNG OR OFFSET PIVOT WITH SINGLE ACTING CONCEALED OVERHEAD CLOSER DOOR JAMB BUTT HUNG OR OFFSET PIVOT 5 TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH LCN CONCEALED OVER HEAD CLOSER OR SURFACE CLOSER kawneer.com ADMD211 22" 1/ (6 5) 3. 2- 2" 1/ (6 5) 3. 90° OUTSIDE CORNER 2-1 /2" (63 .5) 2-1 /2" 135° OUTSIDE CORNER ADMD211 (63 .5) 135° INSIDE CORNER kawneer.com © Kawneer Company, Inc., 2014 CORNERS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1620 SSG Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 8 JUNE, 2015 EC 97911-075 SCALE 3" = 1'-0" NOTE: 1" SYSTEM SHOWN, 1/4" SYSTEM SIMILAR. 90° INSIDE CORNER © Kawneer Company, Inc., 2014 6" (152.4) kawneer.com NOTE: 6" SYSTEM SHOWN, 7-1/2" SYSTEM SIMILAR 1 JAMB MULLION AT SPANDREL (With vapor barrier tie-in) ELEVATION IS NUMBER KEYED TO DETAILS 1-1/2" (38.1) 3-1/4" (82.6) MULLION AT SPANDREL 6 TRANSOM – SPANDREL OVER VISION ADMD211 2 2" (50.8) TYPICAL DEADLOAD ANCHOR MULLION LENGTH 2" (50.8) 4 EXPANSION JOINT 5 MULLION LENGTH 3/8" (9.5) 1/8" (3.2) D.L.O. 6 6" (152.4) 2-3/8" (60.3) 1 D.L.O. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 CONSTRUCTION JOINT 1/2" (12.7) MAX (ALLOWS +/-1/4" MOVEMENT) 1/2" (12.7) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. JUNE, 2015 1620 SSG Curtain Wall System BACKPAN AND MISCELLANEOUS DETAILS SCALE 3" = 1'-0" 3 3 4 HEAD TRANSOM AT PARAPET FLASHING 2 5 9 1620 SSG Curtain Wall System 10 JUNE, 2015 MISCELLANEOUS FRAMING EC 97911-075 SCALE 3" = 1'-0" 2-3/4" (69.85) WITH VAPOR BARRIER TIE-IN 2" (50.8) OPTIONAL MULLION VARIES OPTIONAL SSG MULLION DOUBLE MULLION 7" (177.8) STOOL TRIM OPTIONS: 069264 - 2-3/4" (69.9) 069265 - 4-1/2" (114.3) 069266 - 5" (127.0) 069267 - 6-1/8" (155.6) 069268 - 6-3/4" (171.4) 2-3/4" (69.85) 2" (50.8) 069263 GYPSUM BOARD TRIM NOTE: STOOL TRIMS REQUIRE 069271 TRIM CLIP PACKAGE 2" (50.8) OPTIONAL MULLION OPTIONAL COVER INTERIOR STOOL TRIM ADMD211 kawneer.com © Kawneer Company, Inc., 2014 2" (50.8) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 5" (127) 2-3/4" (69.85) WITH FIBERGLASS PRESSURE PLATE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Architects – Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2015 kawneer.com 1620 SSG Curtain Wall System EC 97911-075 ANCHORING Actual project conditions will determine specific anchor design. Details on this page are for reference only. 1" (25.4) MINIMUM ANCHORING TO FLOOR SLAB 1" (25.4) MINIMUM ANCHORING TO SUPPORT STEEL ADMD211 11 1" (25.4) MINIMUM ANCHORING TO HORIZONTAL STRUCTURAL STEEL 1" (25.4) MINIMUM ANCHORING TO VERTICAL STRUCTURAL STEEL ADMD211 kawneer.com © Kawneer Company, Inc., 2014 ANCHORING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1620 SSG Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 12 JUNE, 2015 EC 97911-075 Actual project conditions will determine specific anchor design. Details on this page are for reference only. JUNE, 2015 1620 SSG Curtain Wall System EC 97911-075 13 WIND LOAD / DEADLOAD CHARTS Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. Wind load charts contained herein are based upon nominal wind load utilized in allowable stress design. To convert ultimate wind loads to nominal loads, multiply ultimate wind loads by a factor of 0.6 per ASCE/SEI 7. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. DEADLOAD CHARTS Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass or 1/4" (6.4) thick glass supported on two setting blocks placed at the loading points shown. © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WIND LOAD CHARTS kawneer.com ADMD211 1620 SSG Curtain Wall System 14 JUNE, 2015 WIND LOAD CHARTS (1/4" and 1" INFILL) SINGLE SPAN TWIN SPAN A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) METERS 2.0 1.0 EC 97911-075 18 METERS 1.0 9.0 5.0 28 15 27 14 26 7 D 6 2.0 5 C 4 1.0 2 1 0 2 3 4 5 6 21 20 6.0 19 A 18 E 5.0 7 D 15 C 14 B 13 I = 2.712(112.88 x 104) S = 1.416(23.2 x 103) 1 22 17 178023 0 7.0 16 B 3 23 4.0 12 0 8 1 2 3 4 5 6 7 MULLION CENTERS IN FEET MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN METERS METERS 2.0 1.0 1.0 18 30 17 29 8 2.0 9.0 5.0 15 27 14 26 4.0 A D 7 C 6 2.0 B 5 MULLION HEIGHT IN FEET E 8 MULLION HEIGHT EQUAL EQUAL 3.0 9 METERS 11 3-3/4" (95.3) 12 10 8.0 25 MULLION HEIGHT 13 MULLION HEIGHT IN FEET 28 24 23 7.0 22 21 A 20 E 6.0 19 18 D 17 4 5.0 16 1.0 3 C 15 178024 2 1 B 14 4.0 13 0 0 1 2 3 4 5 6 7 8 METERS 16 I = 3.260(135.69 x 104) S = 1.712(28.05 x 103) MULLION CENTERS IN FEET 12 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET ADMD211 kawneer.com © Kawneer Company, Inc., 2014 E 24 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. A 8 25 MULLION HEIGHT IN FEET 3.0 9 MULLION HEIGHT EQUAL EQUAL 10 METERS 11 3-3/4" (95.3) 12 MULLION HEIGHT 4.0 13 8.0 METERS 16 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 29 17 MULLION HEIGHT IN FEET 2.0 30 1620 SSG Curtain Wall System JUNE, 2015 EC 97911-075 15 WIND LOAD CHARTS (1/4" and 1" INFILL) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN METERS 2.0 1.0 TWIN SPAN METERS 1.0 18 30 17 29 2.0 5.0 28 15 27 14 26 4.0 10 3.0 E 9 D 8 C 7 B 6 METERS A 2.0 24 A 23 7.0 E 22 21 D 20 6.0 C 19 B 18 17 5 5.0 16 4 1.0 3 15 178025 14 2 4.0 13 1 I = 5.707(237.54 x 104) S = 2.132(34.94 x 103) 0 0 1 2 3 4 5 6 7 12 0 8 1 2 3 4 5 6 7 MULLION CENTERS IN FEET MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN METERS METERS 1.0 2.0 1.0 18 30 17 29 8 2.0 9.0 5.0 15 27 14 26 4.0 3.0 D 9 C 8 B 7 2.0 6 MULLION HEIGHT IN FEET 10 MULLION HEIGHT EQUAL EQUAL E METERS A 5-1/4" (133.4) 12 11 23 C 21 B 20 6.0 19 18 4 16 1.0 7.0 D 22 17 5.0 15 178026 2 8.0 E 24 5 3 A 25 MULLION HEIGHT 13 MULLION HEIGHT IN FEET 28 14 4.0 13 1 0 0 1 2 3 4 5 6 7 8 I = 7.257(302.06 x 104) S = 2.730(44.74 x 103) MULLION CENTERS IN FEET kawneer.com 12 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET ADMD211 8 METERS 16 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. MULLION HEIGHT IN FEET 11 5-1/4" (133.4) 12 MULLION HEIGHT EQUAL EQUAL 25 MULLION HEIGHT 13 8.0 METERS 16 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 9.0 1620 SSG Curtain Wall System 16 JUNE, 2015 WIND LOAD CHARTS (1/4" and 1" INFILL) SINGLE SPAN TWIN SPAN A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) METERS 1.0 EC 97911-075 2.0 18 METERS 1.0 9.0 D 11 10 3.0 B 9 8 METERS C 7 2.0 6 5 MULLION HEIGHT IN FEET 30 MULLION HEIGHT EQUAL EQUAL 12 D C 29 B 28 7.0 27 26 25 6.0 24 23 22 5.0 21 4 1.0 3 20 178026 W/162302 2 1 1 2 3 4 5 6 7 8 4.0 18 Ia = 7.257(302.06 x 104) Sa = 2.730(44.74 x 103) Is = 2.111(87.87 x 104) Ss = 1.108(18.16 x 103) 0 0 19 17 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN METERS METERS 2.0 1.0 1.0 8 2.0 45 18 12.0 44 17 5.0 16 42 A E 11.0 41 D 13 4.0 40 9 8 7 2.0 6 MULLION HEIGHT EQUAL EQUAL 3.0 5-1/4" (133.4) 10 METERS B 11 MULLION HEIGHT C 12 5 39 A 38 10.0 E 37 METERS 14 MULLION HEIGHT IN FEET 15 43 36 35 D 34 9.0 C 33 B 32 4 8.0 31 1.0 3 30 178026 W/162302/303 2 1 0 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET 8 Ia = 7.257(302.06 x 104) Sa = 2.730(44.74 x 103) Is = 3.489(145.22 x 104) Ss = 1.831(30.00 x 103) ADMD211 29 28 7.0 27 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET kawneer.com © Kawneer Company, Inc., 2014 4.0 5-1/4" (133.4) 13 8.0 31 A E MULLION HEIGHT 14 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. E 32 15 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 33 METERS 5.0 16 MULLION HEIGHT IN FEET A 34 17 MULLION HEIGHT IN FEET 2.0 35 1620 SSG Curtain Wall System JUNE, 2015 EC 97911-075 WIND LOAD CHARTS (1/4" and 1" INFILL) SINGLE SPAN 2.0 18 9.0 28 15 27 14 26 6 E 2.0 A 21 20 6.0 19 18 16 1.0 7.0 22 4 B 5.0 C 15 178001 2 14 D 4.0 13 1 I = 4.657(193.84 x 104) S = 1.816(29.76 x 103) 0 1 2 3 4 5 6 7 E 12 0 8 1 2 3 4 5 6 7 MULLION CENTERS IN FEET MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN METERS METERS 1.0 1.0 2.0 8 2.0 30 18 9.0 5.0 29 16 28 15 27 14 26 4.0 10 3.0 B 9 C D E 8 7 2.0 6 METERS A MULLION HEIGHT IN FEET 11 6" (152.4) 12 MULLION HEIGHT EQUAL EQUAL 25 MULLION HEIGHT 13 23 21 B 20 6.0 19 18 4 16 C 5.0 D 15 178002 2 7.0 22 17 1.0 A 24 5 3 8.0 E 14 4.0 13 1 0 0 1 2 3 4 5 6 7 8 I = 6.042(251.49 x 104) S = 2.380(39.00 x 103) MULLION CENTERS IN FEET kawneer.com 12 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET ADMD211 8 METERS 17 MULLION HEIGHT IN FEET 23 17 0 © Kawneer Company, Inc., 2014 24 5 3 8.0 25 MULLION HEIGHT IN FEET 7 B C D 8 MULLION HEIGHT EQUAL EQUAL 3.0 A 9 METERS 11 6" (152.4) 12 MULLION HEIGHT 4.0 10 2.0 29 16 13 MULLION HEIGHT IN FEET 1.0 30 5.0 17 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. METERS METERS 1.0 TWIN SPAN A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) METERS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 17 1620 SSG Curtain Wall System JUNE, 2015 WIND LOAD CHARTS (1/4" and 1" INFILL) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN METERS 2.0 TWIN SPAN METERS 1.0 28 15 27 14 26 4.0 2.0 6 23 7.0 22 B 21 20 6.0 19 C 18 17 5 D 5.0 16 4 1.0 3 E 15 178003 14 2 4.0 13 1 I = 9.414(391.84 x 104) S = 2.782(45.59 x 103) 0 0 1 2 3 4 5 6 7 12 0 8 1 2 3 4 5 6 7 MULLION CENTERS IN FEET MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN METERS METERS 2.0 1.0 1.0 18 8 2.0 30 9.0 5.0 29 16 28 15 27 14 26 4.0 25 11 10 3.0 D E 9 8 7 METERS C MULLION HEIGHT EQUAL EQUAL B 7-1/2" (190.5) 12 MULLION HEIGHT A 2.0 6 MULLION HEIGHT IN FEET 13 23 20 1 6.0 19 D 18 16 2 C 21 4 178004 7.0 22 17 1.0 B 24 5 3 8.0 E 5.0 15 14 4.0 13 0 0 1 2 3 4 5 6 7 8 I = 12.059(501.93 x 104) S = 3.580(58.67 x 103) MULLION CENTERS IN FEET METERS 17 MULLION HEIGHT IN FEET 24 12 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET ADMD211 kawneer.com © Kawneer Company, Inc., 2014 7 MULLION HEIGHT IN FEET D E 8 MULLION HEIGHT EQUAL EQUAL 3.0 C 9 7-1/2" (190.5) 10 METERS B MULLION HEIGHT 11 8.0 25 A 12 A Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 29 16 13 MULLION HEIGHT IN FEET 9.0 5.0 17 2.0 30 18 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1.0 EC 97911-075 METERS 18 1620 SSG Curtain Wall System JUNE, 2015 EC 97911-075 WIND LOAD CHARTS (1/4" and 1" INFILL) SINGLE SPAN 2.0 1.0 18 5.0 METERS 1.0 9.0 32 15 A 4.0 3.0 E 9 8 7 2.0 6 MULLION HEIGHT IN FEET 10 METERS C D 11 7-1/2" (190.5) 12 MULLION HEIGHT EQUAL EQUAL 30 B MULLION HEIGHT 13 29 28 26 25 23 22 21 2 1 3 4 5 6 7 5.0 8 E 19 4.0 18 Ia = 9.414(391.84 x 104) Sa = 2.782(45.59 x 103) Is = 2.111(87.87 x 104) Ss = 1.108(18.16 x 103) 0 2 D 20 178003 W/162302 1 6.0 C 24 4 1.0 7.0 B 27 5 3 8.0 31 17 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN METERS METERS 1.0 2.0 1.0 METERS 14 8 2.0 35 18 9.0 5.0 17 34 33 16 A 14 32 4.0 8 7 2.0 6 MULLION HEIGHT IN FEET 3.0 9 MULLION HEIGHT EQUAL EQUAL 10 METERS D E 11 7-1/2" (190.5) 12 29 28 25 23 21 0 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET kawneer.com 8 E 5.0 20 178003 W/162302/303 1 6.0 D 24 4 2 C 26 22 1.0 7.0 27 5 3 B 30 C MULLION HEIGHT 13 8.0 31 B Ia = 9.414(391.84 x 104) Sa = 2.782(45.59 x 103) Is = 3.489(145.22 x 104) Ss = 1.831(30.00 x 103) ADMD211 19 4.0 18 17 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET 8 METERS 15 MULLION HEIGHT IN FEET A 34 33 0 © Kawneer Company, Inc., 2014 2.0 35 16 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 17 TWIN SPAN A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) METERS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 19 1620 SSG Curtain Wall System JUNE, 2015 WIND LOAD CHARTS (1/4" and 1" INFILL) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN METERS 2.0 18 TWIN SPAN METERS 1.0 9.0 5.0 34 33 16 4.0 8 7 2.0 6 MULLION HEIGHT IN FEET 9 MULLION HEIGHT EQUAL EQUAL 3.0 7-1/2" (190.5) 10 METERS 11 29 28 7.0 27 C 26 25 6.0 24 D 23 22 5 5.0 E 21 4 1.0 3 20 178004 W/162302 2 1 0 1 2 3 4 5 6 7 19 8 4.0 18 Ia = 12.059(501.93 x 104) Sa = 3.580(58.67 x 103) Is = 2.111(87.87 x 104) Ss = 1.108(18.16 x 103) 0 17 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN METERS METERS 1.0 2.0 1.0 8 2.0 35 18 9.0 5.0 17 34 A 16 B 33 32 15 B 13 C D E 4.0 8 7 2.0 6 MULLION HEIGHT IN FEET 3.0 9 MULLION HEIGHT EQUAL EQUAL 10 7-1/2" (190.5) 11 30 MULLION HEIGHT 12 29 26 1 2 3 4 5 6 7 8 5.0 19 Ia = 12.059(501.93 x 10 ) Sa = 3.580(58.67 x 103) Is = 3.489(145.22 x 104) Ss = 1.831(30.00 x 103) 4 0 E 23 20 178004 W/162302/303 0 6.0 24 21 1 D 25 4 2 7.0 27 22 1.0 C 28 5 3 8.0 31 METERS 14 METERS MULLION HEIGHT IN FEET B 30 C D E 12 MULLION HEIGHT 13 8.0 31 B METERS 14 MULLION HEIGHT IN FEET 32 A 15 MULLION CENTERS IN FEET 4.0 18 17 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET ADMD211 kawneer.com © Kawneer Company, Inc., 2014 17 2.0 35 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1.0 EC 97911-075 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 20 1620 SSG Curtain Wall System JUNE, 2015 EC 97911-075 DEADLOAD CHARTS (TUBULAR) A - 1" GLASS (1/4 POINT LOADING) B - 1" GLASS (1/8 POINT LOADING) C - 1/4" GLASS (1/4 POINT LOADING) D - 1/4" GLASS (1/8 POINT LOADING) 6" (152.4) 6" (152.4) 178002 METERS METERS 1.0 1.0 2.0 16 16 15 15 14 14 4.0 13 12 11 10 METERS 3.0 9 8 D 7 2.0 6 11 10 3.0 9 8 D 7 2.0 6 5 5 C B 4 2 C B 4 1.0 3 1.0 3 2 A A 1 0 1 2 3 4 5 6 7 8 0 1 2 3 4 SPAN IN FEET 7-1/2" (190.5) 7-1/2" (190.5) 6 7 8 178004 METERS METERS 1.0 2.0 1.0 16 16 15 15 14 2.0 14 4.0 13 4.0 13 12 GLASS HEIGHT IN FEET 12 11 10 3.0 D 9 8 METERS GLASS HEIGHT IN FEET 5 SPAN IN FEET 178003 © Kawneer Company, Inc., 2014 METERS GLASS HEIGHT IN FEET 12 GLASS HEIGHT IN FEET 4.0 13 1 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2.0 7 2.0 6 5 8 7 2.0 6 C B 1.0 3 A 2 3.0 D 9 4 1.0 3 10 5 C B 4 11 A 2 1 1 0 1 2 3 4 5 6 7 0 8 SPAN IN FEET 1 2 3 4 5 SPAN IN FEET ADMD211 6 7 8 METERS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 178001 kawneer.com 21 1620 SSG Curtain Wall System JUNE, 2015 DEADLOAD CHARTS (OPEN BACK) EC 97911-075 A - 1" GLASS (1/4 POINT LOADING) B - 1" GLASS (1/8 POINT LOADING) C - 1/4" GLASS (1/4 POINT LOADING) D - 1/4" GLASS (1/8 POINT LOADING) 178008 178012 (DOTTED) 7-1/2" (190.5) 178009 178013 (DOTTED) METERS METERS 2.0 16 15 15 14 14 4.0 13 4.0 13 12 10 3.0 9 8 METERS 11 7 2.0 6 5 11 10 3.0 9 8 METERS GLASS HEIGHT IN FEET 12 7 2.0 6 5 4 1.0 3 2 1 0 1 2 3 4 5 6 7 8 D 4 D 1.0 3 C B A C B A 2 1 0 1 2 3 4 5 SPAN IN FEET SPAN IN FEET 6" (152.4) 7-1/2" (190.5) 178014 REINF. 6 7 8 178015 REINF. 178012 178013 METERS METERS 1.0 2.0 1.0 16 16 15 15 2.0 14 14 4.0 13 4.0 13 12 GLASS HEIGHT IN FEET 12 11 10 8 D 7 METERS 3.0 9 2.0 6 11 10 3.0 D 9 8 7 2.0 6 C B 5 5 C B1.0 4 3 2 METERS GLASS HEIGHT IN FEET 2.0 1.0 16 4 1.0 3 A 2 A 1 1 0 1 2 3 4 5 6 7 0 8 SPAN IN FEET 1 2 3 4 5 6 7 8 SPAN IN FEET ADMD211 kawneer.com © Kawneer Company, Inc., 2014 1.0 GLASS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 6" (152.4) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 22 1620 SSG Curtain Wall System JUNE, 2015 EC 97911-075 THERMAL CHARTS Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines) (Based on single bay of Curtain Wall/Window Wall) 8'-0" D.L.O. VISION 2" Typ. 3'-0" D.L.O. 4'-0" D.L.O. VISION 6'-0" D.L.O. SPANDREL 9'-0" D.L.O. 31' SPANDREL VISION 5'-0" D.L.O. Vision Area Example Glass U-factor = 0.28 Btu/(ft2 · h · °F) Vision Area = 5(9 + 8 + 4) = 105.0 ft2 Total Area (Vision)* = 5' 2" (9' 3" + 8' 2" + 4' 2") = 111.5 ft2 Percentage of Vision Glass = (Vision Area ÷ Total Area)100 = (105.0 ÷ 111.5)100 = 94% © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2" Typ. * Area taken to the centerlines of vertical mullions and centerline of horizontal at spandrels. kawneer.com ADMD211 23 System U-factor vs Percent of Vision Area 0.80 90 0.70 85 80 ADMD211 75 0.50 0.40 0.34 0.30 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. THERMAL CHARTS Based on a single curtain wall bay of 94% vision glass and center of glass U-factor of 0.28, System U-factor is equal to 0.34 Btu/(h·ft 2·°F) kawneer.com © Kawneer Company, Inc., 2014 ) 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.60 Btu h·ft 2·°F System U-factor 1620 SSG Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. COG U-factor E IGN PL S M E A D EX OR F T O (N 95 94% 24 JUNE, 2015 EC 97911-075 Vision Area Chart 70 0.20 Vision Area / Total Area (%) JUNE, 2015 1620 SSG Curtain Wall System EC 97911-075 25 THERMAL CHARTS 1620 SSG Curtain Wall Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-Factor for Vision Glass 0.85 0.80 (4.50) 0.75 0.70 (4.00) COG U-factor 0.55 0.46 (2.61) 0.50 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.45 0.38 (2.16) 0.36 (2.05) 0.40 0.34 (1.93) (3.50) (3.00) (2.50) 0.32 (1.82) 0.30 (1.71) 0.35 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) (2.00) 0.30 0.22 (1.25) 0.20 (1.14) © Kawneer Company, Inc., 2014 0.18 (1.02) 0.25 (1.50) 0.16 (0.91) 0.14 (0.80) 0.20 0.12 (0.68) 0.10 (0.57) (1.00) 0.15 Vision Area / Total Area (%) kawneer.com ADMD211 System U-Factor (W/m2·°C) 0.60 System U-Factor (Btu/h·ft2·°F) 0.65 0.48 (2.73) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. (5.00) Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT Vision Ares / Total Area (%) Charts are generated per AAMA 507. ADMD211 kawneer.com © Kawneer Company, Inc., 2014 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC 1620 SSG Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 26 JUNE, 2015 EC 97911-075 1620 SSG Curtain Wall System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Charts are generated per AAMA 507. 1620 SSG Curtain Wall System JUNE, 2015 EC 97911-075 THERMAL PERFORMANCE MATRIX (NFRC SIZE) 1" GLAZING WITH ALUMINUM PRESSURE PLATE Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.56 0.46 0.54 0.44 0.52 0.42 0.51 0.40 0.49 0.38 0.47 0.36 0.46 0.34 0.44 0.32 0.42 0.30 0.40 0.28 0.39 0.26 0.37 0.24 0.35 0.22 0.34 0.20 0.32 0.18 0.29 0.16 0.27 0.14 0.26 0.12 0.24 0.10 0.22 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 27 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.73 0.75 0.69 0.70 0.68 0.70 0.65 0.65 0.63 0.65 0.60 0.60 0.59 0.60 0.55 0.55 0.54 0.55 0.51 0.50 0.50 0.50 0.46 0.45 0.45 0.45 0.41 0.40 0.40 0.40 0.37 0.35 0.36 0.35 0.32 0.30 0.31 0.30 0.28 0.25 0.27 0.25 0.23 0.20 0.22 0.20 0.18 0.15 0.17 0.15 0.14 0.10 0.13 0.10 0.09 0.05 0.08 0.05 0.05 ADMD211 1620 SSG Curtain Wall System JUNE, 2015 EC 97911-075 THERMAL CHARTS 1620 SSG Fiberglass Pressure Plate Curtain Wall (4.50) 0.75 0.70 (4.00) 0.65 0.60 0.48 (2.73) 0.50 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.45 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.40 0.34 (1.93) (3.00) (2.50) System U-Factor (W/m2·°C) 0.55 COG U-factor (3.50) 0.32 (1.82) 0.35 0.30 (1.71) 0.28 (1.59) (2.00) 0.26 (1.48) 0.30 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.25 (1.50) 0.18 (1.02) 0.16 (0.91) 0.20 0.14 (0.80) 0.12 (0.68) (1.00) 0.10 (0.57) 0.15 Vision Area / Total Area (%) Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. ADMD211 kawneer.com © Kawneer Company, Inc., 2014 0.80 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System U-Factor for Vision Glass Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 System U-Factor (Btu/h·ft2·°F) 28 System VT © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2015 kawneer.com 1620 SSG Curtain Wall System EC 97911-075 Vision Area / Total Area (%) ADMD211 29 THERMAL CHARTS 1620 SSG Fiberglass Pressure Plate Curtain Wall System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT 1620 SSG Curtain Wall System JUNE, 2015 EC 97911-075 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Overall U-Factor 4 0.48 0.54 0.46 0.52 0.44 0.51 0.42 0.49 0.40 0.47 0.38 0.45 0.36 0.44 0.34 0.42 0.32 0.40 0.30 0.38 0.28 0.37 0.26 0.35 0.24 0.33 0.22 0.32 0.20 0.30 0.18 0.27 0.16 0.25 0.14 0.24 0.12 0.22 0.10 0.20 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.73 0.75 0.69 0.70 0.68 0.70 0.65 0.65 0.63 0.65 0.60 0.60 0.59 0.60 0.55 0.55 0.54 0.55 0.51 0.50 0.49 0.50 0.46 0.45 0.45 0.45 0.41 0.40 0.40 0.40 0.37 0.35 0.36 0.35 0.32 0.30 0.31 0.30 0.28 0.25 0.26 0.25 0.23 0.20 0.22 0.20 0.18 0.15 0.17 0.15 0.14 0.10 0.13 0.10 0.09 0.05 0.08 0.05 0.05 ADMD211 kawneer.com © Kawneer Company, Inc., 2014 Glass U-Factor 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1" GLAZING WITH FIBERGLASS PRESSURE PLATE Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 30