2500 UT Unitwall™ System JULY, 2015 EC 97911-078 FEATURES Features Optional Features • Steel reinforcing available • Accepts GLASSventTM UT for curtain wall with captured system type •Profit$MakerTM Plus die sets available Product Applications • Suitable for new construction or remodel • Ideal for mid-rise and high-rise applications © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. • 2500 UT Unitwall is a pre-glazed unitized curtain wall • 2-1/2" (63.5) sight line and 7-1/2" (190.5) Captured system depth or 6-1/2" (165.1) 4-side SSG system depth • Prefabricated and shipped knocked-down / assembled and glazed / stock length • Polyamide Thermal Break • Screw spline shop assembly • Shop glazed infill options: - 1" (25.4) insulating vision - 1" (25.4) insulating spandrel • Three system types available: - Captured - 4-side SSG - Vertical SSG • No exterior applied joint seals • Exterior re-glazing capability • 90° and 135° inside and outside corners • Top of slab fully adjustable anchoring ±1" in & out, up & down and left & right • Fully tested including thermal and acoustical • Two color option •PermanodicTM anodized finishes in seven choices • Painted finishes in standard and custom choices For specific product applications, Consult your Kawneer representative. kawneer.com ADMD230 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2500 UT Unitwall™ System BLANK PAGE ADMD230 kawneer.com © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 JULY, 2015 EC 97911-078 JULY, 2015 2500 UT Unitwall™ System EC 97911-078 3 INDEX PICTORIAL VIEWS............................................................................... 4, 5 TYPICAL DETAILS (CAPTURED SYSTEM)............................................6 TYPICAL DETAILS (4-SIDE SSG SYSTEM)............................................7 TYPICAL DETAILS (VERTICAL SSG SYSTEM).....................................8 CORNER DETAILS............................................................................. 9, 10 GLASSventTM UT WINDOWS for CURTAIN WALL ...............................11 ANCHORING..........................................................................................12 WIND LOAD CHARTS.......................................................................13-16 DEADLOAD CHARTS............................................................................17 THERMAL CHARTS..........................................................................18-24 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Architects – Most extrusions illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADMD230 EXTERIOR PICTORIAL VIEW INTERIOR ADMD230 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2500 UT Unitwall™ System TYPICAL UNIT (CAPTURED SYSTEM) kawneer.com © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 JULY, 2015 EC 97911-078 © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2015 kawneer.com 2500 UT Unitwall™ System EC 97911-078 PICTORIAL VIEW EXTERIOR CAPTURED SYSTEM SHOWN ADMD230 5 3 6 5 1 2 6 6 7 7 1/2" (190.5) 4 ADMD230 2 TYPICAL ELEVATION (CAPTURED SYSTEM) 7 3 4 6A OPTIONAL STEEL REINFORCING AS REQUIRED kawneer.com © Kawneer Company, Inc., 2015 TYPICAL DETAILS (CAPTURED SYSTEM) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2500 UT Unitwall™ System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 5 2 1/2" (63.5) 6 JULY, 2015 EC 97911-078 SCALE: 3" = 1'-0" 1 2 © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 5 kawneer.com 6 4 5 2 1/2" (63.5) JULY, 2015 2500 UT Unitwall™ System EC 97911-078 TYPICAL DETAILS (4-SIDE SSG SYSTEM) SCALE: 3" = 1'-0" 1 2 3 1 2 6 1/2" (165.1) 6 6 7 6A OPTIONAL STEEL REINFORCING AS REQUIRED ADMD230 2 TYPICAL ELEVATION (4-SIDE SSG SYSTEM) 7 3 4 7 3 5 1 2 6 6 6 7 7 1/2" (190.5) 4 ADMD230 2 TYPICAL ELEVATION (VERTICAL SSG SYSTEM) 7 3 4 6A OPTIONAL STEEL REINFORCING AS REQUIRED kawneer.com © Kawneer Company, Inc., 2015 TYPICAL DETAILS (VERTICAL SSG SYSTEM) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2500 UT Unitwall™ System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 5 2 1/2" (63.5) 8 JULY, 2015 EC 97911-078 SCALE: 3" = 1'-0" 1 2 © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2015 kawneer.com 2500 UT Unitwall™ System EC 97911-078 CORNER DETAILS (CAPTURED SYSTEM) SCALE: 3" = 1'-0" 90° OUTSIDE CORNER 90° INSIDE CORNER 135° OUTSIDE CORNER 135° INSIDE CORNER ADMD230 9 90° SSG OUTSIDE CORNER 90° SSG INSIDE CORNER 135° SSG OUTSIDE CORNER 135° SSG INSIDE CORNER ADMD230 kawneer.com © Kawneer Company, Inc., 2015 CORNER DETAILS (SSG SYSTEM) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2500 UT Unitwall™ System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 10 JULY, 2015 EC 97911-078 SCALE: 3" = 1'-0" © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2015 kawneer.com 2500 UT Unitwall™ System EC 97911-078 GLASSventTM UT WINDOWS for CURTAIN WALL SCALE: 3" = 1'-0" HEAD SILL JAMB Project-Out GLASSvent™ UT Window Shown Casement Window Similar (With Captured System Only) ADMD230 11 2-1/8" (54) 2-1/8" (54) A A 2" Nominal ±1" Building Tolerance 5-1/4" (133.4) 8" (203.2) 6" (152) 9/16" (14) 9/16" (14) ANCHOR AT JAMB ADMD230 2-7/16" (62) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 3/4" (19) ANCHORING ±1" (25.4) ±1" (25.4) ANCHOR AT MULLION kawneer.com © Kawneer Company, Inc., 2015 2-7/16" (62) ±1" Building Tolerance 1-5/16" (33) 2500 UT Unitwall™ System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 9/16" (14) 2-3/4" (70) 2-3/4" (70) 12 JULY, 2015 EC 97911-078 SEE SECTION CUTS BELOW 6" (152) 9/16" (14) JULY, 2015 2500 UT Unitwall™ System EC 97911-078 13 WIND LOAD CHARTS Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. Wind load charts contained herein are based upon nominal wind load utilized in allowable stress design. To convert ultimate wind loads to nominal loads, multiply ultimate wind loads by a factor of 0.6 per ASCE/SEI 7. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. DEADLOAD CHARTS Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass or 1/4" (6.4) thick glass supported on two setting blocks placed at the loading points shown. © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WIND LOAD CHARTS kawneer.com ADMD230 2500 UT Unitwall™ System 14 JULY, 2015 EC 97911-078 WIND LOAD CHARTS When mullion is used in a SSG application, curves become straight due to structural silicone limits, represented by dashed lines on chart. *Charts are for typical spans, not beginning or ending spans. C/L of stack horizontal to be at noted stool height above C/L of anchor. 1.5 24 23 MULLION CENTERS IN METERS 1.0 23 7.0 22 5.5 18 17 A 5.0 16 15 4.5 B 14 C 13 4.0 D 12 E 10 427001 5 E 15 4.5 14 4.0 13 8 6 I = 9.424 (392.25 x 104) S = 3.208 (52.57 x 103) MULLION CENTERS IN FEET 3.5 3.0 2.5 2 3 4 5 6 MULLION CENTERS IN FEET *MULTI-SPAN 30" SPLICE LOCATION *MULTI-SPAN 36" SPLICE LOCATION MULLION CENTERS IN METERS MULLION CENTERS IN METERS 1.0 1.5 1.0 24 1.5 24 23 6.5 5.5 D 17 E 16 5.0 15 4.5 14 4.0 13 12 10 6.0 C 19 5.5 18 D 17 5.0 16 15 4.5 E 14 4.0 13 12 3.5 11 B 20 MULLION HEIGHT IN FEET C MULLION HEIGHT IN METERS 6.0 B 19 6.5 21 3.5 11 10 3.0 9 MULLION HEIGHT IN METERS A 18 7.0 22 21 20 A 23 7.0 22 MULLION HEIGHT IN FEET 5.0 D 16 9 427002 2.5 4 17 10 9 3 5.5 C 11 3.0 2 B 18 12 3.5 11 6.0 19 MULLION HEIGHT IN METERS 19 A 20 MULLION HEIGHT IN FEET 6.0 6.5 21 MULLION HEIGHT IN METERS MULLION HEIGHT IN FEET 20 8 7.0 22 6.5 21 8 1.5 24 3.0 9 2.5 2 3 4 5 8 6 2.5 2 3 4 5 6 MULLION CENTERS IN FEET MULLION CENTERS IN FEET ADMD230 kawneer.com © Kawneer Company, Inc., 2015 MULLION CENTERS IN METERS 1.0 *MULTI-SPAN 24" SPLICE LOCATION A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SINGLE SPAN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SSG Structural Silicone Limit - Silicone joint contact is .625". 2500 UT Unitwall™ System JULY, 2015 EC 97911-078 15 WIND LOAD CHARTS When mullion is used in a SSG application, curves become straight due to structural silicone limits, represented by dashed lines on chart. *Charts are for typical spans, not beginning or ending spans. C/L of stack horizontal to be at noted stool height above C/L of anchor. SINGLE SPAN with 1/2" x 3-1/2" Steel Bar A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) MULLION CENTERS IN METERS 1.0 1.5 24 23 1.0 5.5 B 5.0 16 C 15 4.5 D 14 E 13 4.0 12 5 WITH 1/2" X 3-1/2" STEEL BAR *MULTI-SPAN 30" SPLICE LOCATION with 1/2" x 3-1/2" Steel Bar (Aluminum) I = 9.424 (392.25 x 104) S = 3.208 (52.57 x 103) (Steel) I = 1.786 (74.34 x 104) S = 1.021 (16.73 x 103) MULLION CENTERS IN METERS 24 2.5 3 2 4 5 6 1.5 1.0 A B 23 7.0 5.0 16 15 4.5 14 4.0 13 10 6.0 19 5.5 18 D 17 5.0 16 15 4.5 E 14 4.0 13 12 3.5 11 C 20 MULLION HEIGHT IN FEET 5.5 E 6.5 21 MULLION HEIGHT IN METERS 6.0 12 3.5 11 10 3.0 9 3.0 9 2.5 2 3 4 5 8 6 2.5 2 3 4 5 6 MULLION CENTERS IN FEET MULLION CENTERS IN FEET kawneer.com 3.0 22 D 17 3.5 MULLION CENTERS IN METERS 7.0 20 18 4.0 13 24 C 19 4.5 14 *MULTI-SPAN 36" SPLICE LOCATION with 1/2" x 3-1/2" Steel Bar 6.5 21 15 MULLION CENTERS IN FEET B 22 MULLION HEIGHT IN FEET 1.5 A 23 5.0 16 8 6 MULLION CENTERS IN FEET 1.0 17 9 427002 2.5 4 5.5 E 10 427001 3 D 18 11 3.0 2 6.0 C 19 12 3.5 11 20 ADMD230 MULLION HEIGHT IN METERS 17 B MULLION HEIGHT IN METERS A 18 MULLION HEIGHT IN FEET 6.0 19 6.5 21 MULLION HEIGHT IN METERS 20 8 7.0 A 22 6.5 21 8 1.5 24 23 9 © Kawneer Company, Inc., 2015 MULLION CENTERS IN METERS 7.0 10 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. *MULTI-SPAN 24" SPLICE LOCATION with 1/2" x 3-1/2" Steel Bar 22 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SSG Structural Silicone Limit - Silicone joint contact is .625". 2500 UT Unitwall™ System 16 JULY, 2015 EC 97911-078 WIND LOAD CHARTS When mullion is used in a SSG application, curves become straight due to structural silicone limits, represented by dashed lines on chart. *Charts are for typical spans, not beginning or ending spans. C/L of stack horizontal to be at noted stool height above C/L of anchor. 1.0 1.5 24 23 MULLION CENTERS IN METERS 1.0 24 B 17 5.5 C 16 5.0 D 15 4.5 E 14 4.0 13 12 10 427001 4 5 6 1.5 (Steel) I = 3.572 (148.67 x 104) S = 2.041 (33.44 x 103) 3.0 2 3 4 5 6 2.5 MULLION CENTERS IN METERS 1.0 1.5 A B 23 7.0 22 6.5 5.0 16 15 4.5 14 4.0 13 12 MULLION HEIGHT IN FEET 5.5 E 10 6.0 19 5.5 18 D 17 5.0 16 15 4.5 E 14 4.0 13 12 3.5 11 C 20 MULLION HEIGHT IN METERS 6.0 19 6.5 21 D 17 3.5 *MULTI-SPAN 36" SPLICE LOCATION with (2) 1/2" x 3-1/2" Steel Bars A 20 MULLION HEIGHT IN FEET (Aluminum) I = 9.424 (392.25 x 104) S = 3.208 (52.57 x 103) 7.0 18 4.0 13 MULLION CENTERS IN FEET C 21 4.5 14 24 23 22 15 WITH (2) 1/2" X 3-1/2" STEEL BARS MULLION CENTERS IN METERS B 5.0 16 8 *MULTI-SPAN 30" SPLICE LOCATION with (2) 1/2" x 3-1/2" Steel Bars 24 17 9 427002 2.5 MULLION CENTERS IN FEET 1.0 5.5 18 10 9 3 6.0 E 19 11 3.0 2 20 12 3.5 11 6.5 D 3.5 11 10 3.0 9 MULLION HEIGHT IN METERS 18 MULLION HEIGHT IN FEET 6.0 19 MULLION HEIGHT IN METERS MULLION HEIGHT IN FEET 20 C 21 A MULLION HEIGHT IN METERS 6.5 21 8 7.0 B 22 22 8 A 23 7.0 1.5 3.0 9 2 3 4 5 6 2.5 8 MULLION CENTERS IN FEET 2 3 4 5 6 2.5 MULLION CENTERS IN FEET ADMD230 kawneer.com © Kawneer Company, Inc., 2015 A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) MULLION CENTERS IN METERS *MULTI-SPAN 24" SPLICE LOCATION with (2) 1/2" x 3-1/2" Steel Bars Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SINGLE SPAN with (2) 1/2" x 3-1/2" Steel Bars Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SSG Structural Silicone Limit - Silicone joint contact is .625". © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. GLASS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-078 0 kawneer.com 0 1 2 3 4 5 A = 1" GLASS (1/4 POINT LOADING) B = 1" GLASS (1/8 POINT LOADING) SPAN IN METERS 1.0 2.0 19 6.0 17 16 13 14 4.0 12 10 11 3.0 9 8 7 B 6 2.0 4 3 2 1 6 7 20 1.0 19 18 427013 5.0 15 I = 1.967 (81.87 x 104) S = 1.515 (24.83 x 103) 17 A 1.0 SPAN IN FEET 8 ADMD230 16 5 427019 I = 1.018 (42.37 x 104) S = 0.728 (11.93 x 103) 13 14 12 0 4.0 10 11 3.0 9 7 8 6 2.0 5 4 3 B 2 1 0 1 2 SPAN IN FEET 3 4 5 6 7 8 1.0 A GLASS HEIGHT IN METERS 427013 GLASS HEIGHT IN FEET 20 GLASS HEIGHT IN METERS JULY, 2015 2500 UT Unitwall™ System 17 DEADLOAD CHARTS SPAN IN METERS 427019 2.0 6.0 18 5.0 15 2500 UT Unitwall™ System JULY, 2015 THERMAL CHARTS EC 97911-078 Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines) 15'-8" Frame Width Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2'-0" D.L.O. 9'-6" Frame Height 7'-0" D.L.O. 5'-0" D.L.O. Example Glass U-Factor = 0.42 Btu/hr • ft2 • °F Total Daylight Opening = 3(5' x 7') + 3(5' x 2') = 135 ft2 Total Projected Area = 15'-8" x 9'-6" = 148.83 ft2 Percent of Glass = (Total Daylight Opening ÷ Total Projected Area)100 = (135 ÷ 148.83)100 = 91% System U-Factor vs Percent of Glass Area 0.80 0.70 E n PL ig M es A rD EX Fo ot (N 0.65 COG U-Factor 0.55 0.50 0.49 0.45 0.40 0.35 0.30 ) 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.60 0.25 70 75 80 85 90 91% 0.20 Vision Area / Total Area % Based on 91% glass and center of glass U-Factor of 0.42 System U-Factor is equal to 0.49 Btu/hr • ft2 • °F ADMD230 kawneer.com © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.75 95 18 2500 UT Unitwall™ System JULY, 2015 EC 97911-078 THERMAL CHARTS Captured System System U-Factor vs Percent of Glass Area Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.70 0.65 0.60 0.55 COG U-Factor 0.46 0.44 0.45 0.42 0.40 0.40 0.38 0.36 0.34 0.35 0.30 0.28 0.30 0.26 0.24 0.22 0.25 0.20 0.18 0.16 0.20 0.14 0.12 © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.32 0.15 0.10 95 90 85 80 75 70 0.10 Vision Area / Total Area % Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. kawneer.com ADMD230 System U-Factor (Btu/hr • ft2 • °F) 0.50 0.48 19 2500 UT Unitwall™ System JULY, 2015 THERMAL CHARTS EC 97911-078 Captured System System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC 0.75 0.70 0.70 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.65 0.65 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 95 90 85 80 75 70 System SHGC 0.60 0.60 0.00 Vision Area / Total Area % (Total Daylight Opening / Projected Area) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Captured System Visible Transmittance (VT) vs Percent of Vision Area COG VT 0.75 0.75 0.70 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 95 90 85 80 75 70 0.00 Vision Area / Total Area % (Total Daylight Opening / Projected Area) ADMD230 kawneer.com © Kawneer Company, Inc., 2015 Charts are generated per AAMA 507 System VT 20 2500 UT Unitwall™ System JULY, 2015 EC 97911-078 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.53 0.46 0.51 0.44 0.50 0.42 0.48 0.40 0.46 0.38 0.45 0.36 0.43 0.34 0.41 0.32 0.40 0.30 0.38 0.28 0.36 0.26 0.34 0.24 0.33 0.22 0.31 0.20 0.29 0.18 0.27 0.16 0.25 0.14 0.23 0.12 0.22 0.10 0.20 Captured System 1" GLAZING NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 21 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.67 0.75 0.67 0.70 0.63 0.70 0.62 0.65 0.58 0.65 0.58 0.60 0.54 0.60 0.53 0.55 0.50 0.55 0.49 0.50 0.45 0.50 0.44 0.45 0.41 0.45 0.40 0.40 0.36 0.40 0.36 0.35 0.32 0.35 0.31 0.30 0.27 0.30 0.27 0.25 0.23 0.25 0.22 0.20 0.18 0.20 0.18 0.15 0.14 0.15 0.13 0.10 0.10 0.10 0.09 0.05 0.05 0.05 0.04 ADMD230 2500 UT Unitwall™ System JULY, 2015 EC 97911-078 THERMAL CHARTS SSG SYSTEM System U-Factor vs Percent of Glass Area 0.65 0.60 0.55 COG U-Factor 0.50 0.46 0.44 0.45 0.42 0.40 0.38 0.40 0.36 0.34 0.32 0.35 0.30 0.28 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.48 0.30 0.26 0.24 0.22 0.25 0.20 0.18 0.16 0.20 0.14 0.12 0.15 0.10 95 90 85 80 75 70 0.10 Vision Area / Total Area % Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. ADMD230 kawneer.com © Kawneer Company, Inc., 2015 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.70 System U-Factor (Btu/hr • ft2 • °F) 22 2500 UT Unitwall™ System JULY, 2015 EC 97911-078 23 THERMAL CHARTS SSG SYSTEM System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC 0.75 0.75 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 95 90 85 80 75 70 System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.70 0.00 Vision Area / Total Area % (Total Daylight Opening / Projected Area) Charts are generated per AAMA 507 SSG SYSTEM COG VT 0.75 0.75 0.70 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 95 90 85 80 Vision Area / Total Area % (Total Daylight Opening / Projected Area) kawneer.com ADMD230 75 70 0.00 System VT 0.50 0.50 © Kawneer Company, Inc., 2015 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Visible Transmittance (VT) vs Percent of Vision Area 2500 UT Unitwall™ System JULY, 2015 EC 97911-078 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Thermal Transmittance 1 (BTU/hr • ft 2 • °F) 0.48 0.54 0.46 0.53 0.44 0.51 0.42 0.49 0.40 0.48 0.38 0.46 0.36 0.44 0.34 0.42 0.32 0.41 0.30 0.39 0.28 0.37 0.26 0.36 0.24 0.34 0.22 0.32 0.20 0.30 0.18 0.28 0.16 0.26 0.14 0.24 0.12 0.22 0.10 0.21 SSG System 1" GLAZING NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.69 0.75 0.67 0.70 0.64 0.70 0.63 0.65 0.60 0.65 0.58 0.60 0.55 0.60 0.54 0.55 0.51 0.55 0.49 0.50 0.46 0.50 0.45 0.45 0.42 0.45 0.40 0.40 0.37 0.40 0.36 0.35 0.33 0.35 0.31 0.30 0.28 0.30 0.27 0.25 0.24 0.25 0.22 0.20 0.19 0.20 0.18 0.15 0.15 0.15 0.13 0.10 0.10 0.10 0.09 0.05 0.06 0.05 0.04 ADMD230 kawneer.com © Kawneer Company, Inc., 2015 Overall U-Factor 4 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 24