27668_Unitwall_flyer.qxd 8/13/08 4:59 PM Page 1 2500 PG Unitwall™ A Unitized Solution the Way You Want it Cathedral Place, Milwaukee, WI Architect: Solomon, Cordwell, Buenz, Chicago, IL Glazing Contractor: Lurie Glass, Milwaukee, WI Today's fast paced construction schedules demand it all – high quality, fast installation, simplified fabrication, superior performance and design flexibility. As budgets continue to tighten and on-site space or skilled labor become more scarce, Kawneer’s unitized solutions balance the need for rapid close-in with design aesthetics, durability and structural integrity. Kawneer’s 2500 PG Unitwall™ is a unitized solution engineered to meet these criteria and more. It is offered in a wide range of options that can be customized to each project. Whether you prefer stock length, fabricated or pre-assembled and glazed – this is a unitized solution, the way you want it. Economy 2500 PG Unitwall™ is customizable to meet the unique conditions of each project. It is available in stock lengths, fabricated or pre-assembled and glazed – offering the flexibility to meet a range of budgets, worker availability and timelines. • With stock lengths, glazing contractors can benefit from the flexibility of providing fabrication and pre-glazing under controlled conditions in their own shop. • Factory fabricated units can help meet tight construction schedules when there is a lack of necessary manpower or equipment. 27668_Unitwall_flyer.qxd 8/13/08 5:00 PM Page 2 • The ideal option to ease timeline pressures, pre-assembled and glazed units ensure quality control and increased productivity for almost any size or configuration. Unitized construction accelerates installation, reducing field labor costs. The system is quickly installed on site with little disruption to existing tenants or to the surrounding area. Rapid installation makes 2500 PG Unitwall™ ideal for new or remodel projects, particularly in urban areas or where space is limited. In addition, shop fabrication facilitates the sorting and recycling of scrap without littering the construction site. With its many advantages, Kawneer’s 2500 PG Unitwall™ allows glazing contractors to competitively bid on bigger projects and take their business to the next level. Performance For today's energy-conscious building owners, a continuous thermal separator is incorporated in 2500 PG Unitwall™. This conserves energy by reducing heat gain / loss. 2500 PG Unitwall™ also offers a back pan option to hold insulation in the spandrel area. With complete Kawneer engineering documentation and support, specifying this product is seamless. Fully tested for thermal and acoustic properties, 2500 PG Unitwall™ ensures the kind of performance that reduces building operating costs and pleases occupants. Aesthetics 2500 PG Unitwall™ offers four glazing options: four-sided captured, two-sided SSG (vertical or horizontal) and four-sided SSG. As an additional bonus on two and four-sided captured glazing options, the continuous thermal separator design, with pressure plates and covers, allows different colors on exterior and interior. 2500 PG Unitwall™ has a 2-1/2" (63.5 mm) profile and a clean appearance without sightline build up. The result is maximum adaptability for any design challenge. For the Finishing Touch Permanodic® Anodized finishes are available in Class I and Class II in seven different colors. Painted Finishes, including fluoropolymer that meet or exceed AAMA 2605, are offered in many standard choices and an unlimited number of specially-designed colors. Solvent-free powder coatings add the “green” element with high performance, durability and scratch resistance that meet the standards of AAMA 2604. University of Toronto, Terrence Donnelly Centre for Cellular and Biomolecular Research, Toronto, Ontario, Canada Architects: architectsAlliance, Toronto, Ontario, Canada; and Behnisch Architekten, Stuttgart, Germany and Los Angeles, CA Glazing Contractor: Ferguson-Neudorf Glass, Inc., Beamsville, Ontario, Canada Kawneer Company, Inc. Technology Park / Atlanta 555 Guthridge Court Norcross, GA 30092 © Kawneer Company, Inc. 2008 kawneer.com 770 . 449 . 5555 LITHO IN U.S.A Printed using soy based inks. Form No. 08-2078 2500 PG WallTM Curtain Wall System DECEMBER, 2014 EC 97911-070 FEATURES Features 2500 PG WallTM is a pre-glazed unitized curtain wall 2-1/2" (63.5) sight lines and 7-1/2" (190.5) system depth Prefabricated and shipped knocked-down Screw spline shop assembly Shop glazed infill options: - 1" (25.4) insulating vision - 1/4" (6.3) or 1" (25.4) insulating spandrel - Spandrel back panning Four system types available: - 4-side captured - 4-side SSG - Vertical SSG - Horizontal SSG Adjustable slab edge, drop-on anchors No exterior applied joint seals Exterior re-glazing capability 90° inside and outside corners ±1/2" total allowable vertical movement per floor Fully tested including thermal and acoustical Two color option PermanodicTM anodized finishes in seven choices Painted finishes in standard and custom choices Optional Features • • • • • • © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. • • • • • • • • • • • • • • • Interior trim options Steel reinforcing Accepts GLASSventTM for curtain wall with 4-side captured system type Available pressure equalization enhancement option Profit$MakerTM Plus die sets available Hurricane impact resistant framing options: 7-1/2" (190.5) Product Applications • Suitable for new construction or remodel • Ideal for mid-rise and high-rise applications For specific product applications, Consult your Kawneer representative. kawneer.com ADMD120 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2500 PG WallTM Curtain Wall System BLANK PAGE ADMD120 kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 DECEMBER, 2014 EC 97911-070 DECEMBER, 2014 2500 PG WallTM Curtain Wall System EC 97911-070 3 INDEX PICTORIAL VIEWS............................................................................... 4, 5 TYPICAL DETAILS (4 SIDE CAPTURED SYSTEM)...............................6 TYPICAL DETAILS (4 SIDE SSG SYSTEM)............................................7 TYPICAL DETAILS (VERTICAL SSG SYSTEM).....................................8 TYPICAL DETAILS (HORIZONTAL SSG SYSTEM)................................9 CORNER DETAILS........................................................................... 10, 11 MISCELLANEOUS DETAILS.................................................................12 GLASSventTM WINDOWS for CURTAIN WALL .....................................13 ANCHORING..........................................................................................14 WIND LOAD CHARTS.......................................................................15-17 DEADLOAD CHARTS.......................................................................18-20 THERMAL CHARTS..........................................................................21-30 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Architects – Most extrusions illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADMD120 EXTERIOR PICTORIAL VIEW INTERIOR ADMD120 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2500 PG WallTM Curtain Wall System TYPICAL UNIT (4-SIDE CAPTURED SYSTEM) kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 DECEMBER, 2014 EC 97911-070 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2014 kawneer.com 2500 PG WallTM Curtain Wall System EC 97911-070 PICTORIAL VIEW VERTICAL SSG SYSTEM SHOWN ADMD120 5 1 4 9 JAMB 1/4" INFILL 7 JAMB 9 HEAD 3 8 5 10 EXPANSION HORIZONTAL 2 6 TYPICAL ELEVATION (4-SIDE CAPTURED SYSTEM) 7-1/2" (190.5) 4-1/4" (108) SHALLOW HORIZONTAL 3 1/4" OVER 1" HORIZONTAL 4 MULLION 1/4" INFILL 8 1" OVER 1" HORIZONTAL 5 7-1/2" (190.5) SILL 6 MULLION 10 ADMD120 kawneer.com © Kawneer Company, Inc., 2013 TYPICAL DETAILS (4-SIDE CAPTURED SYSTEM) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2500 PG WallTM Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 7 2-1/2" (63.5) 2 2-1/2" (63.5) 6 DECEMBER, 2014 EC 97911-070 SCALE: 3" = 1'-0" 1 2500 PG WallTM Curtain Wall System DECEMBER, 2014 EC 97911-070 TYPICAL DETAILS (4-SIDE SSG SYSTEM) SCALE: 3" = 1'-0" 1 HEAD (1/4" INFILL) 2 3 7 4 9 8 10 2 5 EXPANSION SSG HORIZONTAL (1" OVER 1/4") 6 7-1/2" (190.5) TYPICAL ELEVATION (4-SIDE SSG SYSTEM) 3-1/2" (88.9) 3 4 1/4" OVER 1" SSG HORIZONTAL 7 JAMB 1/4" INFILL 8 SSG MULLION 1/4" INFILL 5 1" OVER 1" SSG HORIZONTAL © Kawneer Company, Inc., 2013 7-1/2" (190.5) 6 SILL (1" INFILL) 9 JAMB (1" INFILL) kawneer.com 10 SSG MULLION (1" INFILL) ADMD120 2-1/2" (63.5) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SHALLOW SSG HORIZONTAL (1/4" OVER 1/4") 2-1/2" (63.5) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 7 2500 PG WallTM Curtain Wall System 8 DECEMBER, 2014 TYPICAL DETAILS (VERTICAL SSG SYSTEM) EC 97911-070 SCALE: 3" = 1'-0" 1 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. HEAD (1/4" INFILL) 3 7 4 9 8 10 2 5 EXPANSION HORIZONTAL (1" OVER 1/4") 6 7-1/2" (190.5) TYPICAL ELEVATION (VERTICAL SSG SYSTEM) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3 SHALLOW HORIZONTAL (1/4" OVER 1/4") 2-1/2" (63.5) 3-1/2" (88.9) 4 1/4" OVER 1" HORIZONTAL 7 JAMB 1/4" INFILL 8 SSG MULLION 1/4" INFILL 5 1" OVER 1" HORIZONTAL 6 SILL (1" INFILL) 9 JAMB (1" INFILL) 2-1/2" (63.5) 7-1/2" (190.5) 10 SSG MULLION (1" INFILL) ADMD120 kawneer.com © Kawneer Company, Inc., 2013 2 2500 PG WallTM Curtain Wall System DECEMBER, 2014 EC 97911-070 TYPICAL DETAILS (HORIZONTAL SSG SYSTEM) SCALE: 3" = 1'-0" 1 2 3 7 4 9 8 10 2 5 EXPANSION SSG HORIZONTAL (1" OVER 1/4") 6 7-1/2" (190.5) TYPICAL ELEVATION (HORIZONTAL SSG SYSTEM) 3-1/2" (88.9) 3 4 1/4" OVER 1" SSG HORIZONTAL 7 JAMB 1/4" INFILL 8 MULLION 1/4" INFILL 5 1" OVER 1" SSG HORIZONTAL © Kawneer Company, Inc., 2013 7-1/2" (190.5) 6 SILL (1" INFILL) 9 JAMB (1" INFILL) kawneer.com 10 MULLION (1" INFILL) ADMD120 2-1/2" (63.5) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SHALLOW SSG HORIZONTAL (1/4" OVER 1/4") 2-1/2" (63.5) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 HEAD (1/4" INFILL) 9 OUTSIDE CORNER (1" Infill) OUTSIDE CORNER (1/4" Infill) INSIDE CORNER (1" Infill) INSIDE CORNER (1/4" Infill) ADMD120 kawneer.com © Kawneer Company, Inc., 2013 CORNER DETAILS (CAPTURED SYSTEM) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2500 PG WallTM Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 10 DECEMBER, 2014 EC 97911-070 SCALE: 3" = 1'-0" © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2014 kawneer.com 2500 PG WallTM Curtain Wall System EC 97911-070 CORNER DETAILS (SSG SYSTEM) SCALE: 3" = 1'-0" OUTSIDE CORNER (1" Infill) OUTSIDE CORNER (1/4" Infill) INSIDE CORNER (1" Infill) INSIDE CORNER (1/4" Infill) ADMD120 11 STEEL REINFORCING INTERIOR TRIM AT SILL (Head and Jamb similar) PRESSURE EQUALIZATION ENHANCEMENT OPTION (Captured System) PRESSURE EQUALIZATION ENHANCEMENT OPTION (SSG System) Pressure Equalization Holes LARGE MISSILE IMPACT ADMD120 kawneer.com © Kawneer Company, Inc., 2013 MISCELLANEOUS DETAILS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2500 PG WallTM Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 12 DECEMBER, 2014 EC 97911-070 SCALE: 3" = 1'-0" BACK PAN OPTION Pressure Equalization Holes © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2014 kawneer.com 2500 PG WallTM Curtain Wall System EC 97911-070 GLASSventTM WINDOWS for CURTAIN WALL 1 3 2 ADMD120 13 ANCHORING 1-1/2" (38.1) 3/8" (9.5) or 1/2" (12.7) bolt options as required ±1" (25.4) ANCHOR AT JAMB ADMD120 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. ±1/4" (6.4) 2500 PG WallTM Curtain Wall System ANCHOR AT MULLION kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. ±1" (25.4) 14 DECEMBER, 2014 EC 97911-070 SEE SECTION CUTS BELOW DECEMBER, 2014 2500 PG WallTM Curtain Wall System WIND LOAD CHARTS Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-070 15 kawneer.com ADMD120 2500 PG WallTM Curtain Wall System 16 DECEMBER, 2014 EC 97911-070 WIND LOAD CHARTS When mullion is used in a SSG application, curves become straight due to structural silicone limits, represented by dashed lines on chart. *Charts are for typical spans, not beginning or ending spans. C/L of stack horizontal to be at noted stool height above C/L of anchor. SINGLE SPAN MULLION CENTERS IN METERS 1.0 1.5 17 MULLION CENTERS IN METERS 1.0 1.5 24 23 5.0 7.0 22 14 B 4.0 C D 3.5 E 11 B 18 5.5 C 17 5.0 D 16 E 15 4.5 14 4.0 13 12 3.5 11 10 9 10 3.0 8 2 3 4 5 6 MULLION CENTERS IN FEET 425001 6.5 6.0 18 C 5.5 17 D 5.0 16 E 15 4.5 14 4.0 13 12 3.5 11 10 MULLION HEIGHT IN FEET B 19 21 MULLION HEIGHT IN METERS MULLION HEIGHT IN FEET 23 22 A 5 6 1.5 24 7.0 20 20 19 18 17 16 A B 6.5 6.0 D 5.5 E 5.0 15 4.5 14 4.0 13 3.5 11 10 3.0 7.0 C 12 9 8 1.0 I = 8.797 (366.16 x 104) S = 3.120 (51.13 x 103) 21 4 MULLION CENTERS IN METERS 1.5 24 22 3 *MULTI-SPAN 36" STOOL HEIGHT 425002 MULLION CENTERS IN METERS 23 2.5 2 MULLION CENTERS IN FEET *MULTI-SPAN 30" STOOL HEIGHT 1.0 3.0 9 3.0 9 2.5 2 3 4 5 8 6 MULLION CENTERS IN FEET ADMD120 2.5 2 3 4 5 6 MULLION CENTERS IN FEET kawneer.com © Kawneer Company, Inc., 2013 12 6.0 19 MULLION HEIGHT IN METERS 13 20 MULLION HEIGHT IN FEET 4.5 MULLION HEIGHT IN METERS MULLION HEIGHT IN FEET 15 6.5 A MULLION HEIGHT IN METERS 21 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. A 16 *MULTI-SPAN 24" STOOL HEIGHT A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SSG Structural Silicone Limit - Silicone joint contact is .625". 2500 PG WallTM Curtain Wall System DECEMBER, 2014 EC 97911-070 17 WIND LOAD CHARTS A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) MULLION CENTERS IN METERS 1.0 1.5 18 A *MULTI-SPAN 24" STOOL HEIGHT with 1/2" x 2-1/2" Steel Bar MULLION CENTERS IN METERS 1.0 25 17 7.5 24 23 15 4.5 C 14 13 D 12 E 4.0 425001 425002 WITH 1/2" X 3" STEEL BAR 11 (Aluminum) I = 8.797 (366.16 x 104) S = 3.120 (51.13 x 103) 10 (Steel) I = 3.263 (135.82 x 104) S = 0.750 (12.29 x 103) 3.5 2 3 4 5 6 7.0 22 MULLION HEIGHT IN FEET B MULLION HEIGHT IN METERS 5.0 16 MULLION HEIGHT IN FEET 1.5 26 A 21 6.5 B 20 19 6.0 C 18 5.5 D 17 5.0 16 E 15 4.5 14 4.0 13 12 3.5 11 10 MULLION HEIGHT IN METERS SINGLE SPAN with 1/2" x 3" Steel Bar 2 3 4 5 6 MULLION CENTERS IN FEET MULLION CENTERS IN FEET *MULTI-SPAN 30" STOOL HEIGHT with 1/2" x 2-1/2" Steel Bar *MULTI-SPAN 36" STOOL HEIGHT with 1/2" x 2-1/2" Steel Bar 25 22 21 6.5 B 20 6.0 C 19 D 18 17 5.5 E 5.0 16 15 4.5 14 425002 425001 WITH 1/2" X 2-1/2" STEEL BAR (Aluminum) I = 8.797 (366.16 x 104) S = 3.120 (51.13 x 103) (Steel) I = 1.888 (78.58 x 104) S = 0.521 (8.54 x 103) 4.0 13 12 2 3 4 5 B 21 6.5 C 20 19 6.0 D 18 5.5 E 17 5.0 16 15 4.5 14 4.0 12 3.5 11 10 6 MULLION CENTERS IN FEET kawneer.com 7.0 22 13 3.5 11 A 23 MULLION HEIGHT IN FEET 7.0 A 7.5 24 MULLION HEIGHT IN METERS 23 MULLION HEIGHT IN FEET 25 7.5 24 10 MULLION CENTERS IN METERS 1.0 1.5 26 2 3 4 5 6 MULLION CENTERS IN FEET ADMD120 MULLION HEIGHT IN METERS MULLION CENTERS IN METERS 1.0 1.5 26 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. When mullion is used in a SSG application, curves become straight due to structural silicone limits, represented by dashed lines on chart. *Charts are for typical spans, not beginning or ending spans. C/L of stack horizontal to be at noted stool height above C/L of anchor. Steel bar running from 6" above sill stack to 6" below anchor. 1/2" steel bar as shown running from 6" above stack to 6" below stack above (Unit height - 12"). SSG Structural Silicone Limit - Silicone joint contact is .625". 2500 PG WallTM Curtain Wall System 18 DECEMBER, 2014 EC 97911-070 DEADLOAD CHARTS DEADLOAD CHARTS A = 1/4" GLASS (1/4 POINT LOADING) B = 1" GLASS (1/4 POINT LOADING) 425005 425006 SPAN IN METERS SPAN IN METERS 9 9 8 8 7 2.0 6 5 GLASS HEIGHT IN FEET 10 425005 I = 0.885 (36.84 x 104) S = 0.708 (11.60 x 103) 4 2.0 6 5 4 B A 1.0 1.0 3 3 425006 6 7 2 I = 1.059 (44.08 x 104) S = 0.847 (13.88 x 103) 8 SPAN IN FEET 4 5 6 425007 425008 SPAN IN METERS SPAN IN METERS 2.0 8 2.0 10 9 9 2.0 6 5 8 425007 GLASS HEIGHT IN FEET 7 GLASS HEIGHT IN METERS 10 8 GLASS HEIGHT IN FEET 7 SPAN IN FEET I = 0.868 (36.13 x 104) S = 0.695 (11.39 x 103) 4 7 2.0 6 5 4 A B 1.0 3 1.0 B 3 425008 2 4 5 6 7 SPAN IN FEET 8 I = 0.656 (27.30 x 104) S = 0.702 (11.50 x 103) ADMD120 2 4 5 6 7 8 SPAN IN FEET kawneer.com © Kawneer Company, Inc., 2013 5 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 GLASS HEIGHT IN METERS 2 7 GLASS HEIGHT IN METERS 2.0 10 GLASS HEIGHT IN METERS GLASS HEIGHT IN FEET 2.0 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass or 1/4" (6.35) thick glass supported on two setting blocks placed at the loading points shown. Maximum allowable stress for aluminum is 15,152 PSI (104MPa). 2500 PG WallTM Curtain Wall System DECEMBER, 2014 EC 97911-070 19 DEADLOAD CHARTS A = 1/4" GLASS (1/4 POINT LOADING) B = 1" GLASS (1/4 POINT LOADING) 425011 425012 SPAN IN METERS SPAN IN METERS 9 9 7 2.0 6 5 4 425011 7 2.0 6 5 4 B B 1.0 1.0 3 3 425012 4 5 6 7 2 I = 2.078 (86.50 x 104) S = 1.208 (19.8 x 103) 8 4 5 6 425013 425014 SPAN IN METERS SPAN IN METERS 2.0 10 9 9 7 2.0 6 5 425013 8 I = 2.008 (83.58 x 104) S = 1.607 (26.34 x 103) GLASS HEIGHT IN FEET 8 GLASS HEIGHT IN METERS 10 GLASS HEIGHT IN FEET 8 SPAN IN FEET 2.0 © Kawneer Company, Inc., 2013 7 A 7 2.0 6 5 4 4 B 1.0 1.0 3 3 2 4 5 6 7 SPAN IN FEET kawneer.com 8 425014 I = 2.182 (90.83 x 104) S = 1.288 (21.11 x 103) ADMD120 2 4 5 6 7 SPAN IN FEET 8 GLASS HEIGHT IN METERS 2 SPAN IN FEET Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 8 I = 2.090 (87.00 x 104) S = 1.213 (19.88 x 103) GLASS HEIGHT IN FEET 8 GLASS HEIGHT IN METERS 10 GLASS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 10 GLASS HEIGHT IN METERS 2.0 2.0 GLASS HEIGHT IN FEET 2 2 4 4 425027 2.0 SPAN IN METERS 10 10 9 9 6 5 B 5 6 5 6 7 8 A 7 2.0 6 5 7 8 I = 0.508 (21.15 x 104) S = 0.480 (7.87 x 103) 4 3 8 SPAN IN FEET I = 1.977 (83.08 x 104) S = 1.597 (26.17 x 103) 425027 ADMD120 7 2.0 6 5 4 1.0 3 B 1.0 2 4 5 6 7 8 SPAN IN METERS 10 2.0 9 I = 2.179 (90.70 x 104) S = 1.307 (21.42 x 103) 425030 4 3 1.0 8 SPAN IN FEET kawneer.com Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 425024 SPAN IN METERS GLASS HEIGHT IN METERS DEADLOAD CHARTS © Kawneer Company, Inc., 2013 2.0 425024 GLASS HEIGHT IN FEET 2500 PG WallTM Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 7 GLASS HEIGHT IN METERS 8 GLASS HEIGHT IN METERS GLASS HEIGHT IN FEET 20 DECEMBER, 2014 EC 97911-070 A = 1/4" GLASS (1/4 POINT LOADING) B = 1" GLASS (1/4 POINT LOADING) 2.0 SPAN IN FEET 425030 2500 PG WallTM Curtain Wall System DECEMBER, 2014 EC 97911-070 THERMAL CHARTS Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines) 15'-8" Frame Width 2'-0" D.L.O. 9'-6" Frame Height 7'-0" D.L.O. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 5'-0" D.L.O. Example Glass U-Factor = 0.42 Btu/hr • ft2 • °F Total Daylight Opening = 3(5' x 7') + 3(5' x 2') = 135 ft2 Total Projected Area = 15'-8" x 9'-6" = 148.83 ft2 Percent of Glass = (Total Daylight Opening ÷ Total Projected Area)100 = (135 ÷ 148.83)100 = 91% System U-Factor vs Percent of Glass Area 0.80 0.70 0.60 0.55 0.50 0.45 0.40 0.35 0.30 ) COG U-Factor 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 © Kawneer Company, Inc., 2013 E n PL ig M es A rD EX Fo 0.65 ot (N 0.25 Vision Area / Total Area % Based on 91% glass and center of glass U-Factor of 0.42 System U-Factor is equal to 0.49 Btu/hr • ft2 • °F kawneer.com ADMD120 70 75 80 85 90 91% 0.20 95 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.75 0.49 21 2500 PG WallTM Curtain Wall System 22 DECEMBER, 2014 EC 97911-070 THERMAL CHARTS 0.90 0.60 COG U-Factor 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.50 0.40 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.70 System U-Factor (Btu/hr • ft2 • °F) 0.80 0.30 70 75 80 85 90 95 0.20 Vision Area / Total Area % Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. ADMD120 kawneer.com © Kawneer Company, Inc., 2013 System U-Factor vs Percent of Glass Area Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 4 Side Captured 2500 PG WallTM Curtain Wall System DECEMBER, 2014 EC 97911-070 23 THERMAL CHARTS 4 Side Captured System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area 0.80 COG SHGC 0.75 0.75 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.70 70 75 80 85 95 90 0.00 Vision Area / Total Area % (Total Daylight Opening / Projected Area) Charts are generated per AAMA 507 Visible Transmittance (VT) vs Percent of Vision Area 0.80 COG VT 0.75 0.75 0.70 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 Vision Area / Total Area % (Total Daylight Opening / Projected Area) kawneer.com ADMD120 70 75 80 85 90 95 0.00 System VT 0.50 0.50 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 Side Captured 2500 PG WallTM Curtain Wall System DECEMBER, 2014 EC 97911-070 THERMAL PERFORMANCE MATRIX (NFRC SIZE) 4 Side Captured Thermal Transmittance1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.65 0.46 0.63 0.44 0.62 0.42 0.60 0.40 0.59 0.38 0.57 0.36 0.55 0.34 0.54 0.32 0.52 0.30 0.51 0.28 0.49 0.26 0.48 0.24 0.46 0.22 0.44 0.20 0.43 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.68 0.75 0.66 0.70 0.63 0.70 0.61 0.65 0.59 0.65 0.57 0.60 0.55 0.60 0.53 0.55 0.50 0.55 0.48 0.50 0.46 0.50 0.44 0.45 0.41 0.45 0.39 0.40 0.37 0.40 0.35 0.35 0.33 0.35 0.31 0.30 0.28 0.30 0.26 0.25 0.24 0.25 0.22 0.20 0.19 0.20 0.18 0.15 0.15 0.15 0.13 0.10 0.11 0.10 0.09 0.05 0.06 0.05 0.04 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200. 3. Glass properties are based on center of glass values and are obtained from your glass supplier. 4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). ADMD120 kawneer.com © Kawneer Company, Inc., 2013 SHGC Matrix 2 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 24 2500 PG WallTM Curtain Wall System DECEMBER, 2014 EC 97911-070 25 THERMAL CHARTS Vertical SSG 0.90 0.70 0.60 COG U-Factor 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.50 0.40 0.30 Vision Area / Total Area % Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. kawneer.com ADMD120 70 75 80 85 90 95 0.20 System U-Factor (Btu/hr • ft2 • °F) 0.80 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-Factor vs Percent of Glass Area 26 2500 PG WallTM Curtain Wall System DECEMBER, 2014 EC 97911-070 THERMAL CHARTS Vertical SSG System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area 0.80 COG SHGC 0.75 0.75 0.65 0.60 0.60 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 System SHGC 0.65 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.70 0.70 70 75 80 85 95 90 0.00 Vision Area / Total Area % (Total Daylight Opening / Projected Area) Charts are generated per AAMA 507 Vertical SSG Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.80 COG VT 0.75 0.75 0.70 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 System VT 0.50 0.50 70 75 80 85 90 95 0.00 Vision Area / Total Area % (Total Daylight Opening / Projected Area) ADMD120 kawneer.com © Kawneer Company, Inc., 2013 Visible Transmittance (VT) vs Percent of Vision Area 2500 PG WallTM Curtain Wall System DECEMBER, 2014 EC 97911-070 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Vertical SSG Thermal Transmittance1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.57 0.46 0.56 0.44 0.54 0.42 0.53 0.40 0.51 0.38 0.49 0.36 0.48 0.34 0.46 0.32 0.44 0.30 0.43 0.28 0.41 0.26 0.40 0.24 0.38 0.22 0.36 0.20 0.35 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SHGC Matrix 2 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.69 0.75 0.66 0.70 0.65 0.70 0.61 0.65 0.61 0.65 0.57 0.60 0.56 0.60 0.53 0.55 0.52 0.55 0.48 0.50 0.47 0.50 0.44 0.45 0.43 0.45 0.39 0.40 0.39 0.40 0.35 0.35 0.34 0.35 0.31 0.30 0.30 0.30 0.26 0.25 0.25 0.25 0.22 0.20 0.21 0.20 0.18 0.15 0.17 0.15 0.13 0.10 0.12 0.10 0.09 0.05 0.08 0.05 0.04 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200. 3. Glass properties are based on center of glass values and are obtained from your glass supplier. 4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). kawneer.com ADMD120 27 28 2500 PG WallTM Curtain Wall System DECEMBER, 2014 EC 97911-070 THERMAL CHARTS Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 4 Side SSG Vision Area / Total Area % Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. ADMD120 kawneer.com © Kawneer Company, Inc., 2013 COG U-Factor Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System U-Factor (Btu/hr • ft2 • °F) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-Factor vs Percent of Glass Area © Kawneer Company, Inc., 2013 System VT Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2014 kawneer.com 2500 PG WallTM Curtain Wall System EC 97911-070 Vision Area / Total Area % (Total Daylight Opening / Projected Area) ADMD120 29 THERMAL CHARTS 4 Side SSG System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area % (Total Daylight Opening / Projected Area) Charts are generated per AAMA 507 4 Side SSG Visible Transmittance (VT) vs Percent of Vision Area COG VT 2500 PG WallTM Curtain Wall System DECEMBER, 2014 EC 97911-070 THERMAL PERFORMANCE MATRIX (NFRC SIZE) 4 Side SSG Thermal Transmittance1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.56 0.46 0.55 0.44 0.53 0.42 0.51 0.40 0.50 0.38 0.48 0.36 0.46 0.34 0.45 0.32 0.43 0.30 0.42 0.28 0.40 0.26 0.38 0.24 0.37 0.22 0.35 0.20 0.33 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.70 0.75 0.66 0.70 0.65 0.70 0.61 0.65 0.61 0.65 0.57 0.60 0.57 0.60 0.53 0.55 0.52 0.55 0.48 0.50 0.48 0.50 0.44 0.45 0.43 0.45 0.39 0.40 0.39 0.40 0.35 0.35 0.35 0.35 0.31 0.30 0.30 0.30 0.26 0.25 0.26 0.25 0.22 0.20 0.21 0.20 0.18 0.15 0.17 0.15 0.13 0.10 0.13 0.10 0.09 0.05 0.08 0.05 0.04 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200. 3. Glass properties are based on center of glass values and are obtained from your glass supplier. 4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). ADMD120 kawneer.com © Kawneer Company, Inc., 2013 SHGC Matrix 2 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 30