NX-series Analog Output Unit NX-DA CSM_NX-DA_DS_E_2_5 Analog Outputs to meet all machine control needs; from general-purpose outputs to highspeed synchronous, highresolution control outputs • Analog Output Units for the NX-series modular I/O system. • Connect to other NX-series I/O Units and EtherCAT Coupler units using the high-speed NX-bus. • Separate modules for voltage- and current outputs. Features • Up to four analog outputs per unit. • Free-Run refreshing or Synchronous I/O refreshing, Task Period Prioritized refreshing *, can be selected for refreshing with the NX-series EtherCAT Coupler. • Output update cycles of 10 μs per channel, and resolution of 1/30000, ideal for high-speed, high-precision control. • The screwless terminal block is detachable for easy commissioning and maintenance. • Screwless push-in terminal block significantly reduces wiring work. • All models are just 12 mm wide, saving space in your cabinet. * Task Period Prioritized refreshing is available when the NX-ECC203 is used together. System Configuration Sysmac Studio Support Software EtherCAT master* NJ/NX-series CPU Unit Connection to peripheral USB port or built-in EtherNet/IPTM port on NJ/NX-series CPU Unit Built-in EtherCAT port Sysmac Studio Support Software ●EtherCAT Slave Terminal Communications cable Ethernet cables Peripheral USB port. NX Series EtherCAT Coupler Unit NX-ECC@@@ Connection to peripheral USB port on EtherCAT Coupler Unit NX Units End Cover * OMRON CJ1W-NC@81/@82 Position Control Units cannot be connected to the EtherCAT Slave Terminal even though they support EtherCAT. Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products. EtherCAT® is a registered trademark of Beckhoff Automation GmbH for their patented technology. Other company names and product names in this document are the trademarks or registered trademarks of their respective companies. 1 NX-DA Ordering Information International Standards • The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, CE: EC Directives,and KC: KC Registration. • Contact your OMRON representative for further details and applicable conditions for these standards. Analog Output Unit Specification Unit type Product Name Voltage Output Unit Capacity Input range Resolution Over all accuracy (25°C) 1/8000 -4000 to 4000 ±0.3% 250 μs/point (full scale) Free-Run refreshing 1.10W max. NX-DA2603 1.10W max. NX-DA2605 Current Output Unit Model Standards -15000 to 15000 ±0.1% 10 μs/point (full scale) 1/8000 -4000 to 4000 ±0.3% 250 μs/point (full scale) Free-Run refreshing 1.25W max. NX-DA3603 1/30000 -15000 to 15000 ±0.1% 10 μs/point (full scale) Selectable Synchronous I/O refreshing or Free-Run refreshing 1.25W max. NX-DA3605 1/8000 0 to 8000 ±0.3% 250 μs/point (full scale) Free-Run refreshing 1.75W max. NX-DA2203 1/30000 0 to 30000 ±0.1% 10 μs/point (full scale) Selectable Synchronous I/O refreshing or Free-Run refreshing 1.75W max. NX-DA2205 1/8000 0 to 8000 ±0.3% 250 μs/point (full scale) Free-Run refreshing 1.80W max. NX-DA3203 0 to 30000 ±0.1% 10 μs/point (full scale) Selectable Synchronous I/O refreshing or Free-Run refreshing 1.80W max. NX-DA3205 2 points 4 to 20mA I/O refreshing method 1/30000 4 points NX Series Analog Output Unit Conversion time Selectable Synchronous I/O refreshing or Free-Run refreshing 2 points -10 to +10V NX Unit power consumption Output setting value, decimal number (0 to 100%) 4 points 1/30000 UC1,N, L, CE,KC Option Product Name Unit/Terminal Block Coding Pins Specification Model For 10 Units (Terminal Block: 30 pins, Unit: 30 pins) NX-AUX02 Standards --- Specification Product Name Terminal Block No. of terminals 8 12 Terminal number indications A/B Ground terminal mark None Terminal current capacity 10 A Model NX-TBA082 NX-TBA122 Standards --- Accessories Not included. 2 NX-DA General Specification Item Enclosure Specification Mounted in a panel Grounding method Ground to 100 Ω or less Ambient operating temperature 0 to 55°C Ambient operating humidity 10% to 95% (with no condensation or icing) Atmosphere Must be free from corrosive gases. Ambient storage temperature −25 to 70°C (with no condensation or icing) Altitude 2,000 m max. Pollution degree Operating Noise immunity environment Overvoltage category 2 or less: Conforms to JIS B3502 and IEC 61131-2. 2 kV on power supply line (Conforms to IEC61000-4-4.) Category II: Conforms to JIS B3502 and IEC 61131-2. EMC immunity level Zone B Vibration resistance Conforms to IEC 60068-2-6. 5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz, acceleration of 9.8 m/s2, 100 min each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total) Shock resistance IConforms to IEC 60068-2-27. 147 m/s2, 3 times each in X, Y, and Z directions Applicable standards cULus: Listed UL508 and ANSI/ISA 12.12.01 EC: EN 61131-2 and C-Tick, KC Registration, NK, LR 3 NX-DA Analog Output Unit Specifications Analog Output Unit (voltage output type) 2points NX-DA2603 Unit name Analog Output Unit (voltage output type) Model NX-DA2603 Capacity 2 points External connection terminals Screwless clamping terminal block (8 terminals) I/O refreshing method Free-Run refreshing Output range -10 to +10 V Output conversion range -5 to 105% (full scale) Allowable load resistance 5 kΩ min. Output impedance 0.5 Ω max. TS indicator Indicator Resolution 1/8000 (full scale) 25°C Overall accuracy 0 to 55°C ±0.3% (full scale) Conversion time 250 μs/point ±0.5% (full scale) Dimensions 12 (W) x 100 (H) x 71 (D) Isolation method Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC) Dielectric strength 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. I/O power supply method Supply from the NX bus Current capacity of I/O power supply terminal IOV: 0.1 A/terminal max., IOG: 0.1 A/terminal max. NX Unit power consumption 1.10 W max. I/O current consumption No consumption Weight 70 g max. IOV AMP Output V1+ to V2+ IOG Circuit layout AG: Analog circuit internal GND NX bus connector (left) Installation orientation and restrictions AG I/O power supply + I/O power supply + I/O power supply − I/O power supply − NX bus connector (right) Installation orientation: Possible in 6 orientations. Restrictions: No restrictions Additional I/O Power Supply Unit A1 Terminal connection diagram Terminal block B1 Voltage Output Unit NX-DA2603 A1 B1 IOV IOV V1+ V2+ Voltage output + IOG IOG IOV IOV Voltage output − IOV IOV IOG IOG IOG IOG NC NC 24 VDC A8 B8 A8 B8 4 NX-DA Analog Output Unit (voltage output type) 2points NX-DA2605 Unit name Analog Output Unit (voltage output type) Model NX-DA2605 Capacity 2 points External connection terminals Screwless clamping terminal block (8 terminals) I/O refreshing method Selectable Synchronous I/O refreshing or Free-Run refreshing TS indicator Indicator Output range -10 to +10 V Output conversion range -5 to 105% (full scale) Allowable load resistance 5 kΩ min. Output impedance 0.5 Ω max. Resolution 1/30000 (full scale) 25°C Overall accuracy 0 to 55°C ±0.1% (full scale) Conversion time 10 μs/point ±0.3% (full scale) Dimensions 12 (W) x 100 (H) x 71 (D) Isolation method Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC) Dielectric strength 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. I/O power supply method Supply from the NX bus Current capacity of I/O power supply terminal IOV: 0.1 A/terminal max., IOG: 0.1 A/terminal max. NX Unit power consumption 1.10 W max. I/O current consumption No consumption Weight 70 g max. IOV AMP Output V1+ to V2+ Circuit layout IOG AG: Analog circuit internal GND NX bus connector (left) Installation orientation and restrictions AG I/O power supply + I/O power supply + I/O power supply − I/O power supply − NX bus connector (right) Installation orientation: Possible in 6 orientations. Restrictions: No restrictions Additional I/O Power Supply Unit A1 Terminal connection diagram Terminal block B1 Voltage Output Unit NX-DA2605 A1 B1 IOV IOV V1+ V2+ Voltage output + IOG IOG IOV IOV Voltage output − IOV IOV IOG IOG IOG IOG NC NC 24 VDC A8 B8 A8 B8 5 NX-DA Analog Output Unit (voltage output type) 4points NX-DA3603 Unit name Analog Output Unit (voltage output type) Model NX-DA3603 Capacity 4 points External connection terminals Screwless clamping terminal block (12 terminals) I/O refreshing method Free-Run refreshing Output range -10 to +10 V Output conversion range -5 to 105% (full scale) Allowable load resistance 5 kΩ min. Output impedance 0.5 Ω max. TS indicator Indicator Resolution 1/8000 (full scale) 25°C Overall accuracy 0 to 55°C ±0.3% (full scale) Conversion time 250 μs/point ±0.5% (full scale) Dimensions 12 (W) x 100 (H) x 71 (D) Isolation method Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC) Dielectric strength 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. I/O power supply method Supply from the NX bus Current capacity of I/O power supply terminal IOV: 0.1 A/terminal max., IOG: 0.1 A/terminal max. NX Unit power consumption 1.25 W max. I/O current consumption No consumption Weight 70 g max. IOV AMP Output V1+ to V4+ Circuit layout IOG AG: Analog circuit internal GND NX bus connector (left) Installation orientation and restrictions AG I/O power supply + I/O power supply + I/O power supply − I/O power supply − NX bus connector (right) Installation orientation: Possible in 6 orientations. Restrictions: No restrictions Additional I/O Power Supply Unit A1 B1 IOV Terminal connection diagram Terminal block IOG Voltage Output Unit NX-DA3603 A1 IOV IOG 24 VDC IOV IOG A8 IOV B1 V1+ V2+ IOV IOV IOG IOG V3+ V4+ IOV IOV IOG IOG Voltage output + Voltage output − IOG B8 A8 B8 6 NX-DA Analog Output Unit (voltage output type) 4points NX-DA3605 Unit name Analog Output Unit (voltage output type) Model NX-DA3605 Capacity 4 points External connection terminals Screwless clamping terminal block (12 terminals) I/O refreshing method Selectable Synchronous I/O refreshing or Free-Run refreshing TS indicator Indicator Output range -10 to +10 V Output conversion range -5 to 105% (full scale) Allowable load resistance 5 kΩ min. Output impedance 0.5 Ω max. Resolution 1/30000 (full scale) 25°C Overall accuracy 0 to 55°C ±0.1% (full scale) Conversion time 10 μs/point ±0.3% (full scale) Dimensions 12 (W) x 100 (H) x 71 (D) Isolation method Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC) Dielectric strength 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. I/O power supply method Supply from the NX bus Current capacity of I/O power supply terminal IOV: 0.1 A/terminal max., IOG: 0.1 A/terminal max. NX Unit power consumption 1.25 W max. I/O current consumption No consumption Weight 70 g max. IOV AMP Output V1+ to V4+ Circuit layout IOG AG: Analog circuit internal GND NX bus connector (left) Installation orientation and restrictions AG I/O power supply + I/O power supply + I/O power supply − I/O power supply − NX bus connector (right) Installation orientation: Possible in 6 orientations. Restrictions: No restrictions Additional I/O Power Supply Unit A1 B1 IOV Terminal connection diagram Terminal block IOG Voltage Output Unit NX-DA3605 A1 IOV IOG 24 VDC IOV IOG A8 IOV B1 V1+ V2+ IOV IOV IOG IOG V3+ V4+ IOV IOV IOG IOG Voltage output + Voltage output − IOG B8 A8 B8 7 NX-DA Analog Output Unit (current output type) 2points NX-DA2203 Unit name Analog Output Unit (current output type) Model NX-DA2203 Capacity 2 points External connection terminals Screwless clamping terminal block (8 terminals) I/O refreshing method Free-Run refreshing Output range 4 to 20 mA Output conversion range -5 to 105% (full scale) Allowable load resistance 600 Ω min. TS indicator Indicator Resolution 1/8000 (full scale) 25°C Overall accuracy 0 to 55°C ±0.3% (full scale) Conversion time 250 μs/point ±0.6% (full scale) Dimensions 12 (W) x 100 (H) x 71 (D) Isolation method Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC) Dielectric strength 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. I/O power supply method Supply from the NX bus Current capacity of I/O power supply terminal IOV: 0.1 A/terminal max., IOG: 0.1 A/terminal max. NX Unit power consumption 1.75 W max. I/O current consumption No consumption Weight 70 g max. IOV AMP Output I1+ to I2+ Circuit layout Terminal block IOG AG: Analog circuit internal GND NX bus connector (left) AG I/O power supply + I/O power supply + I/O power supply − I/O power supply − NX bus connector (right) Installation orientation: Possible in 6 orientations. Restrictions: For upright installation: No restrictions For any installation other than upright: Restricted as shown in the graph below. Installation orientation and restrictions Load resistance (per point) (Ω) 600 350 Use it within this range. 0 55 (°C) 40 Ambient operating temperature Additional I/O Power Supply Unit A1 Terminal connection diagram B1 Current Output Unit NX-DA2203 A1 B1 IOV IOV I1+ I2+ Current output + IOG IOG IOV IOV Current output − IOV IOV IOG IOG IOG IOG NC NC 24 VDC A8 B8 A8 B8 8 NX-DA Analog Output Unit (current output type) 2points NX-DA2205 Unit name Analog Output Unit (current output type) Model NX-DA2205 Capacity 2 points External connection terminals Screwless clamping terminal block (8 terminals) I/O refreshing method Selectable Synchronous I/O refreshing or Free-Run refreshing TS indicator Indicator Output range 4 to 20 mA Output conversion range -5 to 105% (full scale) Allowable load resistance 600 Ω min. Resolution 1/30000 (full scale) 25°C Overall accuracy 0 to 55°C ±0.1% (full scale) Conversion time 10 μs/point ±0.3% (full scale) Dimensions 12 (W) x 100 (H) x 71 (D) Isolation method Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC) Dielectric strength 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. I/O power supply method Supply from the NX bus Current capacity of I/O power supply terminal IOV: 0.1 A/terminal max., IOG: 0.1 A/terminal max. NX Unit power consumption 1.75 W max. I/O current consumption No consumption Weight 70 g max. IOV AMP Output I1+ to I2+ Circuit layout Terminal block IOG AG: Analog circuit internal GND NX bus connector (left) AG I/O power supply + I/O power supply + I/O power supply − I/O power supply − NX bus connector (right) Installation orientation: Possible in 6 orientations. Restrictions: For upright installation: No restrictions For any installation other than upright: Restricted as shown in the graph below. Installation orientation and restrictions Load resistance (per point) (Ω) 600 350 Use it within this range. 0 55 (°C) 40 Ambient operating temperature Additional I/O Power Supply Unit A1 Terminal connection diagram B1 Current Output Unit NX-DA2205 A1 B1 IOV IOV I1+ I2+ Current output + IOG IOG IOV IOV Current output − IOV IOV IOG IOG IOG IOG NC NC 24 VDC A8 B8 A8 B8 9 NX-DA Analog Output Unit (current output type) 4points NX-DA3203 Unit name Analog Output Unit (current output type) Model NX-DA3203 Capacity 4 points External connection terminals Screwless clamping terminal block (12 terminals) I/O refreshing method Free-Run refreshing Output range 4 to 20 mA Output conversion range -5 to 105% (full scale) Allowable load resistance 350 Ω min. TS indicator Indicator Resolution 1/8000 (full scale) 25°C Overall accuracy 0 to 55°C ±0.3% (full scale) Conversion time 250 μs/point ±0.6% (full scale) Dimensions 12 (W) x 100 (H) x 71 (D) Isolation method Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC) Dielectric strength 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. I/O power supply method Supply from the NX bus Current capacity of I/O power supply terminal IOV: 0.1 A/terminal max., IOG: 0.1 A/terminal max. NX Unit power consumption 1.80 W max. I/O current consumption No consumption Weight 70 g max. IOV AMP Output I1+ to I4+ Circuit layout Terminal block IOG AG: Analog circuit internal GND NX bus connector (left) AG I/O power supply + I/O power supply + I/O power supply − I/O power supply − NX bus connector (right) Installation orientation: Possible in 6 orientations. Restrictions: For upright installation: No restrictions For any installation other than upright: Restricted as shown in the graph below. Installation orientation and restrictions Load resistance (per point) (Ω) 350 250 Use it within this range. 0 55 (°C) 40 Ambient operating temperature Additional I/O Power Supply Unit A1 B1 IOV Terminal connection diagram IOG Current Output Unit NX-DA3203 A1 IOV IOG 24 VDC IOV IOG A8 IOV B1 I1+ I2+ IOV IOV IOG IOG I3+ I4+ IOV IOV IOG IOG Current output + Current output − IOG B8 A8 B8 10 NX-DA Analog Output Unit (current output type) 4points NX-DA3205 Unit name Analog Output Unit (current output type) Model NX-DA3205 Capacity 4 points External connection terminals Screwless clamping terminal block (12 terminals) I/O refreshing method Selectable Synchronous I/O refreshing or Free-Run refreshing TS indicator Indicator Output range 4 to 20 mA Output conversion range -5 to 105% (full scale) Allowable load resistance 350 Ω min. Resolution 1/30000 (full scale) 25°C Overall accuracy 0 to 55°C ±0.1% (full scale) Conversion time 10 μs/point ±0.3% (full scale) Dimensions 12 (W) x 100 (H) x 71 (D) Isolation method Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) Insulation resistance 20 MΩ min. between isolated circuits (at 100 VDC) Dielectric strength 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. I/O power supply method Supply from the NX bus Current capacity of I/O power supply terminal IOV: 0.1 A/terminal max., IOG: 0.1 A/terminal max. NX Unit power consumption 1.80 W max. I/O current consumption No consumption Weight 70 g max. IOV AMP Output I1+ to I4+ Circuit layout Terminal block IOG AG: Analog circuit internal GND NX bus connector (left) AG I/O power supply + I/O power supply + I/O power supply − I/O power supply − NX bus connector (right) Installation orientation: Possible in 6 orientations. Restrictions: For upright installation: No restrictions For any installation other than upright: Restricted as shown in the graph below. Installation orientation and restrictions Load resistance (per point) (Ω) 350 250 Use it within this range. 0 55 (°C) 40 Ambient operating temperature Additional I/O Power Supply Unit A1 B1 IOV Terminal connection diagram IOG Current Output Unit NX-DA3205 A1 IOV IOG 24 VDC IOV IOG A8 IOV B1 I1+ I2+ IOV IOV IOG IOG I3+ I4+ IOV IOV IOG IOG Current output + Current output − IOG B8 A8 B8 11 NX-DA Version Information NX Unit Corresponding unit versions/versions * EtherCAT Coupler Units Model Unit Version NJ/NX-series CPU Units Sysmac Studio NX-ECC20@ NX-DA@@@@ Ver.1.0 Version 1.0 or later Version 1.05 or later Version 1.06 or higher * Some Units do not have all of the versions given in the above table. If a Unit does not have the specified version, support is provided by the oldest available version after the specified version. Refer to the user’s manuals for the specific Units for the relation between models and versions. External Interface Analog Output Unit NX-DA@@@@ 12mm Width (B) (C) (A) Symbol (A) (B) (C) Name NX bus connector Indicators Terminal block Function This connector is used to connect each Unit. The indicators show the current operating status of the Unit. The terminal block is used to connect external devices. The number of terminals depends on the type of Unit. Terminal Blocks (A) (B) A1 B1 A1 B1 A2 B2 A2 B2 A3 B3 A3 B3 A4 B4 A4 B4 A5 B5 A5 B5 A6 B6 A6 B6 A7 B7 A7 B7 A8 B8 A8 B8 (C) 12 mm width 8-terminal type Symbol Name (A) Terminal number indications (B) (C) Release holes Terminal holes 12 mm width 12-terminal type Function Terminal numbers for which A to D indicate the column, and 1 to 8 indicate the line are displayed. The terminal number is a combination of column and line, so A1 to A8 and B1 to B8 are displayed. The terminal number indications are the same regardless of the number of terminals on the terminal block. Insert a flat-blade screwdriver into these holes to connect and remove the wires. The wires are inserted into these holes. 12 NX-DA Applicable Terminal Blocks for Each Unit Model Unit model Model NX-DA2@@@ NX-DA3@@@ NX-TBA082 NX-TBA122 No. of terminals 8 12 Terminal Blocks Terminal number indications A/B A/B Ground terminal mark None None Terminal current capacity 10 A 10 A Applicable Wires Using Ferrules If you use ferrules, attach the twisted wires to them. Observe the application instructions for your ferrules for the wire stripping length when attaching ferrules. Always use plated one-pin ferrules. Do not use unplated ferrules or two-pin ferrules. The applicable ferrules, wires, and crimping tool are given in the following table. Terminal types Manufacturer Terminals other than ground terminals Phoenix Contact Ground terminals Terminals other than ground terminals Weidmuller Ferrule model number AI0,34-8 AI0,5-8 AI0,5-10 AI0,75-8 AI0,75-10 AI1,0-8 AI1,0-10 AI1,5-8 AI1,5-10 AI2,5-10 H0.14/12 H0.25/12 H0.34/12 H0.5/14 H0.5/16 H0.75/14 H0.75/16 H1.0/14 H1.0/16 H1.5/14 H1.5/16 Applicable wire (mm2 (AWG)) Crimping tool 0.34 (#22) 0.5 (#20) Phoenix Contact (The figure in parentheses is the applicable wire size.) CRIMPFOX 6 (0.25 to 6 mm2, AWG24 to 10) 0.75 (#18) 1.0 (#18) 1.5 (#16) 2.0 * 0.14 (#26) 0.25 (#24) 0.34 (#22) 0.5 (#20) Weidmuller (The figure in parentheses is the applicable wire size.) PZ6 Roto (0.14 to 6 mm2, AWG 26 to 10) 0.75 (#18) 1.0 (#18) 1.5 (#16) * Some AWG 14 wires exceed 2.0 mm2 and cannot be used in the screwless clamping terminal block. When you use any ferrules other than those in the above table, crimp them to the twisted wires so that the following processed dimensions are achieved. Finished Dimensions of Ferrules 8 to 10 mm 1.6 mm max. (except ground terminals) 2.4 mm max. (except ground terminals) 2.0 mm max. (ground terminals) 2.7 mm max. (ground terminals) Using Twisted Wires/Solid Wires If you use the twisted wires or the solid wires, use the following table to determine the correct wire specifications. Terminals Classification Current capacity Wire type Twisted wires Plated 2 A max. All terminals except ground terminals Ground terminals Greater than 2 A and 4 A or less Possible Greater than 4 A Possible *1 --- Possible Solid wire Unplated Plated Unplated Possible Possible Possible Not Possible Possible Possible *1 Not Possible Possible *2 Not Possible Possible *2 Wire size Conductor length (stripping length) 0.08 to 1.5 mm2 AWG28 to 16 8 to 10 mm 2.0 mm2 9 to 10 mm *1 Secure wires to the screwless clamping terminal block. Refer to the Securing Wires in the USER'S MANUAL for how to secure wires. *2 With the NX-TB@@@1 Terminal Block, use twisted wires to connect the ground terminal. Do not use a solid wire. Conductor length (stripping length) <Additional Information> If more than 2 A will flow on the wires, use plated wires or use ferrules. 13 NX-DA Dimensions (Unit/mm) Analog Output Unit NX-DA@@@@ 12 mm Width 14.1 12.0 0.55 1.5 100 1.5 104.5 65.2 71 80.1 Related Manuals Cat. No. W522 Model number Manual name NX-AD@@@@ NX-series Analog I/O NX-DA@@@@ Units User’s Manual NX-TS@@@@ Application Description Learning how to use NX-series The hardware, setup methods, and functions of the NXAnalog I/O Units and series Analog I/O Units and Temperature Input Units Temperature Input Units are described. 14 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2016.4 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2016 All Right Reserved.