Power Delivery Solutions Product Selection Guide Battery Back Up Units • DC backup system that actively manages DC battery banks • Increases system uptime by providing DC power to load in the event of an AC power failure • If the input fails, the load is switched seamlessly to batteries • Continuously monitors DC output voltage of power supply • Extensive monitoring is provided via LEDs and outputs Battery Back Up Unit for DC Power Management LOADS BBU 12 Battery Back Up BATTERY + BATTERY EXT. PS + LOAD - 991628 0024 24VDC BATTERY BACK-UP UNIT r Description Part No. 24 VDC input 9916280024 r % \ r Class 1, Div. 2 Dimensions mm (in.) Dimensions mm (in.) BATTERY OPEN BATTERY LOW BATTERY REVERSE CHARGING FULL CHARGE FAULT 115-230VAC. 1.0A-0.6A B.B.U. ONLY I MAX. = 10A (RMS) = B.B.U. + EXT. PS 50/60Hz 127.5 (5.02) + ENABLE + DRAIN + DRAIN RESET - COM BAT STATUS MAX. 1A @30VDC FAULT RELAY MAX. 1A @30VDC L AC IN g B.B.U. N AC OUT g EXT. PS N % LGN BBU AC IN DC OUTPUT 15A MAX. LOAD - L 9916280012 r % \ r Class 1, Div. 2 CLASS 1, DIVISION 2 GROUPS A, B, C &D T4A SEE SIDE PANEL EXT. PS LOAD + LOAD + Part No. 12 VDC Input Power Supply Battery BBU 24 Description ® LISTED 9ZX0 127.5 (5.02) AC INPUT r 161 (6.34) PS AC INPUT 161 (6.34) 72.5 (2.85) 72.5 (2.85) DC/DC Converters DC-DC converter used to convert solar array output (24 VDC in this case) that is used for powering 24 VDC input/output devices, to 12 VDC used for power to lower cost radio transmitter. The transmitter panel (remote monitoring system) transmits information to SCADA system that can monitor the conditions/physical properties at the remote site, taking corrective actions, alarming, or simply providing information on conditions at remote site. Remote Monitoring SUN Antenna Antenna CP-DCDC 50W 12 VDC Input CP-DCDC 50W 24 VDC Input Solar Cell Description Part No. 22-24 VDC @ 2 A 24VDC I/O Devices and Sensors I/O 24VDC Radio Transmitter 12V (powered) 12VDC + + OUTPUT - SCADA System or Other Type of Control System 15VDC 3A V out Adjust 9919371224 Description Part No. 22-24 VDC @ 2 A 9919372424 15 VDC @ 3 A 9919371215 15 VDC @ 3 A 9919372415 12 VDC @ 3 A 9919371212 12 VDC @ 3 A 9919372412 5 VDC @ 8 A 9919371205 5 VDC @ 8 A 9919372405 r % v r Class 1, Div. 2 r % v r Class 1, Div. 2 Dimensions mm (in.) Dimensions mm (in.) DC ON + - INPUT 12VDC ±15% 2.37A ±15% 24VDC 98 (2.24) 98 (2.24) REMOTE MONITORING 131 (5.16) 57 (3.86) 131 (5.16) 57 (3.86) Power Supply Comparison Table 85-265 120-300 INSTAPOWER CP SNT 24W X 85-265 120-300 X CP SNT 25W X 85-264 110-370 X CP SNT 48W X 85-264 110-370 CP SNT 70W X 85-264 120-370 X X X X CP SNT 120W X 88-132/176-264 250-370 X X X X CP SNT 250W X 88-132/176-264 250-370 X X X X CP SNT 500W X 88-132/176-264 250-370 X X X X ECO PRO-M PRO-H Advanced Class 1 Zone 2 Approval X Class 1 Division 2 Approval CP SNT 12W Class 2 Approval WAVE Load Sharing w/o External Diode Status Relay 200% 125% Adjustable Output 48 VDC 24 VDC 12 VDC 5 VDC Additional Features DC 110% Output Power Boost Output Voltage AC Three-Phase Single-Phase Input Voltage Description Series/Family X X X X X X X X X X X CP SNT3 120W X 340-575 450-800 X X X X CP SNT3 250W X 340-575 450-800 X X X X CP SNT3 500W X 340-575 450-800 X X X X CP SNT3 1000W X 340-575 450-800 X X X X CP M SNT 70W X 85-264 80-370 X X X CP M SNT 120W X 85-264 80-370 X X X CP M SNT 180W X 85-264 80-370 X X X CP M SNT 250W X 85-264 80-370 X X X CP M SNT 500W X 85-264 80-370 X X X CP M SNT 1000W X 85-264 80-370 X X X CP M SNT3 120W X 320-575 450-800 X X X CP M SNT3 250W X 320-575 450-800 X X X CP M SNT3 500W X 320-575 450-800 X X X CP M SNT3 1000W X 320-575 450-800 X X X X X X X X X X X X X X X X X X CP T SNT 70W X 85-132/187-264 n/a X CP T SNT 140W X 85-132/187-264 n/a X CP T SNT 90W X 85-132/187-264 n/a X CP T SNT 180W X 85-132/187-264 n/a X X X X X X X CP T SNT 360W X 85-132/187-264 n/a X X X X X X X CP T SNT 600W X 85-132/187-264 n/a X X X X X X X CP SNT 55W X 85-265 120-300 X X X X X X X CP SNT 160W X 85-138/195-250 280-370 X X X X X X X X X X CP SNT 300W X X X X X X X X X X X 85-265 100-200 X CP SNT 55W X 306-550 450-800 X X CP SNT 160W X 342-528 450-800 X X SINGLE-PHASE 120/230VAC PRO-M CP M SNT 70W • DIN-rail mount with no ventilation gap required • Space efficient designs allow for installation in small locations CP M SNT 120W Description Part No. Description Part No. 24 VDC 3 A 8951330000 24 VDC 5 A 8951340000 %{\ to UL508A, rC22.2 no.107.1 L x W x H: 125 x 33 x 130 mm (3.92 x 1.3 x 5.12 in) %{\ to UL508A, rC22.2 no.107.1 L x W x H: 125 x 40 x 130 mm (3.92 x 1.58 x 5.12 in) • Flexibility with a wide range of AC/DC inputs • Single-phase and three-phase versions, from 70 W to 1000 W • 120% power boost feature for high inrush applications • Operating temperature range of -25°C to +70°C • MTBF > 500,000 Hours • cULus to UL 508 and CSA C22.2 No.107.1 SINGLE-PHASE 120/230VAC ECO CP SNT 70W CP SNT 120W Description Part No. Description Part No. • Ideal for OEMs, panel shops, and control manufacturing 24 VDC 3 A 8708660000 24 VDC 5 A 8708670000 • Provide a cost-effective power delivery solution for basic requirements LxWxH: 110 x 55.5 x 125 mm (4.33 x 2.19 x 4.92 in) %\ %\ to UL508A, rC22.2 no.107.1 to UL508A, rC22.2 no.107.1 L x W x H: 110 x 65.5 x 125 mm (4.33 x 2.58 x 4.92 in) • Flexibility of wide range of output current from 3 Amps to 40 Amps • Status relay outputs • Operating temperature range of -10°C to +55°C, model dependent • cULus to UL 508 and CSA C22.2 No.107.1 SINGLE-PHASE 120/230VAC PRO-H CP T SNT 70W CP T SNT 140W Description • Class 1, Division 2 approvals • 125% power boost feature for high inrush applications 12 VDC 6A Part No. Description Part No. 1105430000 12 VDC 12 A 1105440000 Approvals - See table at right Approvals - See table at right L x W x H: 110 x 35 x 110 mm (4.33 x 1.38 x 4.33 in) L x W x H: 110 x 54 x 110 mm (4.33 x 2.12 x 4.33 in) • Cold start-up at full load at -25°C • DC-OK signal and external shut down function • Output voltages of 12, 14 and 48VDC • Operating temperature range of -25°C to +70°C • MTBF > 900,000 Hours SINGLE-PHASE 120/230VAC Advanced CP SNT 55W • Load sharing capability • 200% of maximum rated output for a specified amount of time (power boost) • Available with low residual ripple (< 10mV in some cases) • Single-phase and three-phase versions Description 24…28 VDC 2.3 A 48 VDC 1.04 A 12…15 VDC 3 A 5 VDC 3 A CP SNT 160W Part No. 9927480024* 9927480048 9927480012* 9927480005 Description 24…28 VDC 6.5 A 5 VDC 10 A 48 VDC 3.25 A 9.5…15 VDC 10 A Part No. 9925340024* 9925340005 9925340048* 9925340012 r % v r % v L x W x H: 57 x 98 x 131 mm (2.24 x 3.86 x 5.16 in) L x W x H: 57 x 127 x 175 mm (2.24 x 5.0 x 6.89 in) • Many available in 5, 12, 24, 28, and 48V versions • Rugged housing can be panel mounted • Operating temperature range of -20°C to +50°C, model dependent • Available with status relay and analog outputs for monitoring *r Class 1, Div. 2 CP M SNT 180W Description 24 VDC 7.5 A %{\ CP M SNT 250W CP M SNT 500W Description Part No. Description Part No. Description Part No. 8951350000 24 VDC 10A 8951360000 24 VDC 20A 8951370000 24 VDC 40A 8951380000 to UL508A, rC22.2 no.107.1 Lx W x H: 150 x 50 x 130 mm (5.91 x 1.97 x 5.12 in) %{\ to UL508A, rC22.2 no.107.1 L x Wx H: 150 x 60 x 130 mm (5.91 x 2.37 x 5.12 in) %{\ to UL508A, rC22.2 no.107.1 L x W x H: 150 x 121 x 130 mm (5.91 x 4.77 x 5.12 in) THREE-PHASE CP SNT 250W CP SNT 500W Description Part No. 24 VDC 10 A 8708680000 %\ 24 VDC 16 A-20 A CP T SNT 90W CP SNT3 250W Description Part No. Description Part No. 8778870000 24 VDC 5 A 8862730000 24 VDC 10 A 8708700000 %\ to UL508A, rC22.2 no.107.1 L x Wx H: 110 x 227.5 x 125 mm (4.33 x 8.96 x 4.92 in) %\ to UL508A, rC22.2 no.107.1 L x W x H: 110 x 90 x 125 mm (4.33 x 3.54 x 4.92 in) CP T SNT 360W to UL508A, rC22.2 no.107.1 L x W x H: 110 x 125.5 x 125 mm (4.33 x 4.94 x 4.92 in) CP T SNT 600W Part No. Description Part No. Description Part No. 24 VDC 7.5 A 1105810000 24 VDC 15 A 1105820000 24 VDC 25 A 1105840000 Approvals - See table at right 48V 4 A 1105850000 48V 7.5 A 1105860000 48V 12.5 A 1105870000 Lx W x H: 110 x 35 x 110 mm (4.33 x 1.38 x 4.33 in) Approvals - See table at right Approvals - See table at right Approvals - See table at right L x Wx H: 110 x 54 x 110 mm (4.33 x 2.12 x 4.33 in) L x W x H: 125 x 80 x 125 mm (4.92 x 3.15 x 4.92 in) L x W x H: 125 x 165 x 125 mm (4.92 x 6.5 x 4.92 in) 24 VDC 3.8 A 1105790000 Description to UL508A, rC22.2 no.107.1 Part No. CP T SNT 180W Part No. %{\ L x W x H: 150 x 180 x 130 mm (5.91 x 7.09 x 5.12 in) 380/480VAC CP SNT3 120W Description %\ to UL508A, rC22.2 no.107.1 Lx W x H: 110 x 125.5 x 125 mm (4.33 x 4.94 x 4.92 in) Description CP M SNT 1000W Part No. THREE-PHASE 380/480VAC CP SNT 300W Description CP SNT 55W Part No. Description 24 VDC 2.3 A CP SNT 160W Part No. Description 22…28 VDC 12.5 A 9916250024 r % v r Class 1, Div. 2 r% \ r% \ Lx Wx H: 240 x 104 x 155 mm (9.45 x 4.09 x 6.10 in) L x Wx H: 60 x 108 x 168 mm (2.36 x 4.25 x 6.61 in) L x W x H: 58.4 x 138.2 x 177.8 mm (2.3 x 5.44 x 7.0 in) 9917790324 24…28 VDC 6.5 A Part No. 9925340324 INSTAPOWER THREE-PHASE 380/480VAC CP M SNT3 120W CP M SNT3 250W Description 24 VDC 5A %{\ CP M SNT3 500W CP M SNT3 1000W Part No. Description Part No. Description Part No. Description Part No. 8951390000 24 VDC 10A 8951400000 24 VDC 20A 8951410000 24 VDC 40A 8951420000 %{\ to UL508A, rC22.2 no.107.1 Lx Wx H: 125 x 40 x 130 mm (4.92 x 1.58 x 5.12 in) to UL508A, rC22.2 no.107.1 L x Wx H: 150 x 60 x 130 mm (5.91 x 2.37 x 5.12 in) %{\ to UL508A, rC22.2 no.107.1 L x W x H: 150 x 121 x 130 mm (5.91 x 4.77 x 5.12 in) %{\ to UL508A, rC22.2 no.107.1 LxWxH: 150 x 180 x 130 mm (5.91 x 7.09 x 5.12 in) SINGLE-PHASE 120/230VAC CP SNT3 500W CP SNT3 1000W Description Part No. Description Part No. 24 VDC 20 A 8708710000 24 VDC 40 A 8708730000 %\ %\ to UL508A, rC22.2 no.107.1 Lx Wx H: 110 x 227.5 x 125 mm (4.33 x 8.96 x 4.92 in) to UL508A, rC22.2 no.107.1 LxWxH: 125 x 280 x 150 mm (4.92 x 11.02 x 5.91 in) WAVEPower • Slim, 22.5 mm WAVE housing • Flexibility with a wide-range of AC and DC input CP SNT 12W Description 24 VDC 0.5 A Part No. 9918840024 % r v 508 Listed LxWxH: 90 x 18 x 112.5 mm (3.54 x 0.71 x 4.43 in) • Output voltage adjustable via potentiometer • LED status indicator • Option for connecting in parallel • Operating temperature range of -20°C to +50°C Approvals v file E236157 \ Listed to UL508, CSA C22.2 No. 14 v file E255651 { to ANSI/UL60950, CSA60950 r file 246286 r to C22.2 No. 107.1 r file 246286 C US r file 246286 C US C US r file 246286 to CSA60950, ANSI/UL60950 C1D2 to C22.2 No. 213, UL1604, Group A, B, C, D C1Z2 to CSA60079-15, UL60079-15 & ANSI/ISA 12.012.01, Ex nC IIC T4U, Aex nC IIC T4U IEC file SI-1729 B3 % marked LCIE file 10 ATEX 1015U T to EN60079-0, EN60079-15 (Ex nAC IIC T4 or T5 with derating) SINGLE-PHASE 120/230VAC CP SNT 24W • Flexibility with a wide-range of AC and DC input • Output voltage adjustable via potentiometer • LED status indicator • Option for connecting in parallel • Operating temperature range of -20°C to +50°C, model dependent • International approvals for use world-wide CP SNT 25W Description Part No. 24 VDC 1 A 9928890024 4…8 VDC 5 A CP SNT 48W Description Part No. 8754960000 Description Part No. 9…15 VDC 4 A 8754970000 28 VDC 1 A 9928890028 r, %, v 508, { 60950, GS Class 2 15…28 VDC 2A 8739140000 15 VDC 1.5 A 9928890015 L x W x H: 70 x 90.5 x 62.5 mm (2.76 x 3.56 x 2.46 in) 46…55 VDC 1A 8879230000 12 VDC 1.5 A 9928890012 r, %, v 508, { 60950, GS Class 2 5 VDC 2 A 9928890005 L x W x H: 70 x 90.5 x 62.5 mm (2.76 x 3.56 x 2.46 in) r, v 508 Listed, % r Class 1 Div. 2 and Zone 2 for 9928890012 and 9928890024, v 1310 (Class 2) for 9928890024 L x Wx H: 52 x 90.5 x 62.5 mm (2.05 x 3.56 x 2.46 in) Diode and Redundancy Modules Parallel Connection for Increased Power Delivery 24VDC/20Amp PRO-M 10Amp Power Supply 10Amp Power Supply OUT +V +V -V -V 230VAC 230VAC 115VAC 115VAC 8710620000 CP DM 10 8708680000 CP SNT 250W 24V 10A Input 24V=2x10A Output 24V=20A 8708680000 CP SNT 250W 24V 10A DC OK L N PE 12 11 14 +V DC OK +V -V E1 -V -V -V E2 L N PE 12 11 14 +V +V -V -V ECO IN 24VDC/10Amp PRO-H CP DM 10 • The amount of power needed is provided by two power supplies combined in parallel CP DM 20 Description Part No. 10 A per input 8710620000 % \ Description Part No. 20 A per input 8768650000 % \ Dimensions mm (in.) Provide Uninterrupted DC Power with Redundancy and Fault Indication (this example supplying 7A to load) Diode Module 24VDC/7Amp 10Amp Power Supply Dimensions mm (in.) Advanced 125 (4.92) +V -V -V 230VAC 230VAC 115VAC 115VAC 8708680000 CP SNT 250W 24V 10A 8710620000 CP DM 10 Input 24V=2x10A Output 24V=20A 8708680000 CP SNT 250W 24V 10A DC OK L N PE 12 11 14 +V DC OK +V -V -V E1 -V -V E2 L N PE 12 11 14 +V +V -V -V IN 110 (4.33) 55.5 (2.19) 110 (4.33) 55.5 (2.19) 24VDC/3.5Amp 24VDC/3.5Amp Status Relays (Change-Over-Contact) e.g. to PLC, IPC or Fieldbus Status Relays (Change-Over-Contact) e.g. to PLC, IPC or Fieldbus PRO-M • Diode modules provide galvanic isolation between power supplies 03. UNINTERRUPTED DC POWER WITH REDUNDANCY AND FAULT INDICATION • Use status relays for remote alarm indication ECO Increase DC Power Delivery to Control Systems (this example supplying 14A to load) Diode Module 24VDC/14Amp 10Amp Power Supply CP T RM 10* PRO-H 10Amp Power Supply OUT +V 125 (4.92) 24VDC/10Amp CP T RM 20* Description Part No. 2 x 24 VDC input 15A 1105880000 Description Dimensions mm (in.) Advanced Dimensions mm (in.) 110 (4.33) 110 (4.33) 110 (4.33) -V 230VAC 115VAC 8708680000 CP SNT 250W 24V 10A 1105890000 8710620000 CP DM 10 Input 24V=2x10A Output 24V=20A 8708680000 CP SNT 250W 24V 10A DC OK N PE 12 11 14 +V DC OK +V -V E1 -V -V -V E2 L N PE 12 11 14 +V +V -V -V IN 24VDC/7Amp 24VDC/7Amp Status Relays (Change-Over-Contact) e.g. to PLC, IPC or Fieldbus 110 (4.33) 35 (2.19) -V 115VAC L % \ T +V 230VAC Part No. 2 x Control input 25A % \ T 10Amp Power Supply OUT +V Status Relays (Change-Over-Contact) e.g. to PLC, IPC or Fieldbus 04. INCREASED DC POWER DELIVERY TO CONTROL SYSTEMS • The amount of power needed is provided by two power supplies combined in parallel • Use status relays for remote alarm indication 54 (2.12) * Only these diode modules carry a hazardous approval rating. For Larger Inputs PRO-M Guarantee DC Power to Critical Loads (this example supplying 3A to critical load) 24VDC/3Amp 10Amp Power Supply 24VDC/10Amp OUT +V +V -V -V Critical Loads Diode Module 24VDC/10Amp 230VAC 115VAC 8708680000 CP SNT 250W 24V 10A 8710620000 CP DM 10 Input 24V=2x10A Output 24V=20A Status Relays (Change-Over Contact) e.g. to PLC, IPC or Fieldbus ECO DC OK Non-critical Loads CP DM 30 PRO-H Part No. CP DM 30 with voltage sensing and fault relay CP DM 30 without voltage sensing Description Advanced Dimensions mm (in.) 9987390000 20 A per input (2 x 20) max. 7940005219 9987860000 40 A per input (1 x 40) max. 7940005218 70 (2.75) 110 (4.33) 99 (3.90) 109.2 (4.30) 12 11 14 +V +V -V E1 -V -V -V E2 IN 12 11 10 V+ V+ V- V- DC OK 8703660000 CP SNT 70A 24V 3A Dimensions mm (in.) 155 (6.10) PE Part No. \ va N 24VDC/10Amp Status Relays (Change-Over Contact) e.g. to PLC, IPC or Fieldbus RSD 40 Description L 109.2 (4.30) 24Amp Power Supply 24VDC/3Amp L N PE • Under normal operating conditions, the critical load is provided by both the 05. GUARANTEE DC POWER TO CRITICAL LOADS 10A and 3A power supply • If the larger power supply fails, the critical load will continue to be maintained by the 3A power supply • This ensures uninterrupted power to the critical load Note: Two power supplies in parallel must be calibrated to within ± 50 mv of each other. www.weidmuller.com Argentina Australia Austria Azerbaijan Bahrain Belarus Belgium BosniaHerzegovina Brazil Bulgaria Canada Chile China Colombia Costa Rica Croatia Czech Republic Denmark Ecuador Egypt Estonia Finland France Germany Greece Hong Kong Hungary Iceland India Indonesia Iran Ireland Israel Italy Japan Jordan Kazakhstan Kuwait Latvia Lebanon Lithuania Luxembourg Macedonia Malaysia Malta Mexico Montenegro Netherlands New Zealand Norway Oman Paraguay Peru Philippines Poland Portugal Qatar Romania Russia Saudi Arabia Serbia Weidmuller, Canada 10 Spy Court Markham, Ontario L3R 5H6 Telephone: (800) 268-4080 Facsimile: (877) 300-5635 Email:[email protected] Website:www.weidmuller.ca 10/11 • 6M • LIT0703 Singapore Slovakia Slovenia South Africa South Korea Spain Sweden Switzerland Syria Taiwan Thailand Turkey UAE Ukraine United Kingdom Uruguay USA Venezuela Vietnam Yemen Weidmuller is the leading manufacturer of components for electrical connection technology to transmit energy, signals and data. The Weidmuller product portfolio ranges from terminal blocks, PCB connectors and terminals, protected c omponents, Industrial Ethernet components, I/O components and relay sockets to power supplies and overvoltage protection m odules suitable for all applications. Assemble Services, marking solutions with a variety of tools and software systems, round off the range. As an OEM supplier, the company sets global standards in the field of electrical connection technology. Weidmuller, Mexico Blvd. Hermanos Serdán 698, Col. San Rafael Oriente Puebla, Puebla, Mexico C.P. 72029, Telephone: 01 222 2686267 Facsimile: 01 222 2686219 Email:[email protected] Website:www.weidmuller.com.mx Weidmuller, United States 821 Southlake Blvd. Richmond, Virginia 23236 Telephone: (800) 849-9343 Facsimile: (804) 379-2593 Email:[email protected] Website:www.weidmuller.com PRO-M THREE-PHASE CP M SNT 70W • DIN-rail mount with no ventilation gap required • Space efficient designs allow for installation in small locations CP M SNT 120W CP M SNT 180W Description Part No. Description Part No. 24 VDC 3 A 8951330000 24 VDC 5 A 8951340000 %{\ to UL508A, rC22.2 no.107.1 L x W x H: 125 x 33 x 130 mm (3.92 x 1.3 x 5.12 in) %{\ to UL508A, rC22.2 no.107.1 L x W x H: 125 x 40 x 130 mm (3.92 x 1.58 x 5.12 in) Description 24 VDC 7.5 A %{\ CP M SNT 250W CP M SNT 500W CP M SNT 1000W CP M SNT3 120W Part No. Description Part No. Description Part No. Description Part No. 8951350000 24 VDC 10A 8951360000 24 VDC 20A 8951370000 24 VDC 40A 8951380000 to UL508A, rC22.2 no.107.1 L x W x H: 150 x 50 x 130 mm (5.91 x 1.97 x 5.12 in) %{\ to UL508A, rC22.2 no.107.1 L x W x H: 150 x 60 x 130 mm (5.91 x 2.37 x 5.12 in) %{\ to UL508A, rC22.2 no.107.1 L x W x H: 150 x 121 x 130 mm (5.91 x 4.77 x 5.12 in) %{\ 380/480VAC to UL508A, rC22.2 no.107.1 LxWxH: 150 x 180 x 130 mm (5.91 x 7.09 x 5.12 in) CP M SNT3 250W Description 24 VDC 5A %{\ CP M SNT3 500W CP M SNT3 1000W Part No. Description Part No. Description Part No. Description Part No. 8951390000 24 VDC 10A 8951400000 24 VDC 20A 8951410000 24 VDC 40A 8951420000 %{\ to UL508A, rC22.2 no.107.1 LxWxH: 125 x 40 x 130 mm (4.92 x 1.58 x 5.12 in) to UL508A, rC22.2 no.107.1 LxWxH: 150 x 60 x 130 mm (5.91 x 2.37 x 5.12 in) %{\ to UL508A, rC22.2 no.107.1 LxWxH: 150 x 121 x 130 mm (5.91 x 4.77 x 5.12 in) %{\ to UL508A, rC22.2 no.107.1 LxWxH: 150 x 180 x 130 mm (5.91 x 7.09 x 5.12 in) • Flexibility with a wide range of AC/DC inputs Diode and Redundancy Modules Parallel Connection for Increased Power Delivery L 230VAC 115VAC 8710620000 CP DM 10 24V=2x10A Output 24V=20A 8708680000 CP SNT 250W 24V 10A N PE 12 11 14 +V DC OK +V -V E1 -V -V -V E2 L N PE 12 11 14 +V +V -V -V ECO PRO-H THREE-PHASE CP SNT 70W CP SNT 120W CP SNT 250W CP SNT 500W Description Part No. Description Part No. Description Part No. 24 VDC 3 A 8708660000 24 VDC 5 A 8708670000 24 VDC 10 A 8708680000 %\ %\ to UL508A, rC22.2 no.107.1 LxWxH: 110 x 55.5 x 125 mm (4.33 x 2.19 x 4.92 in) %\ to UL508A, rC22.2 no.107.1 L x W x H: 110 x 65.5 x 125 mm (4.33 x 2.58 x 4.92 in) 24 VDC 16 A-20 A L x W x H: 110 x 125.5 x 125 mm (4.33 x 4.94 x 4.92 in) CP SNT3 250W CP SNT3 500W CP SNT3 1000W Part No. Description Part No. Description Part No. Description Part No. Description Part No. 8778870000 24 VDC 5 A 8862730000 24 VDC 10 A 8708700000 24 VDC 20 A 8708710000 24 VDC 40 A 8708730000 %\ to UL508A, rC22.2 no.107.1 L x W x H: 110 x 227.5 x 125 mm (4.33 x 8.96 x 4.92 in) %\ to UL508A, rC22.2 no.107.1 L x W x H: 110 x 90 x 125 mm (4.33 x 3.54 x 4.92 in) %\ to UL508A, rC22.2 no.107.1 LxWxH: 110 x 125.5 x 125 mm (4.33 x 4.94 x 4.92 in) %\ to UL508A, rC22.2 no.107.1 LxWxH: 110 x 227.5 x 125 mm (4.33 x 8.96 x 4.92 in) to UL508A, rC22.2 no.107.1 LxWxH: 125 x 280 x 150 mm (4.92 x 11.02 x 5.91 in) WAVEPower • Slim, 22.5 mm WAVE housing • Flexibility with a wide-range of AC and DC input 24 VDC 0.5 A Part No. 9918840024 % r v 508 Listed % \ Provide Uninterrupted DC Power with Redundancy and Fault Indication (this example supplying 7A to load) Diode Module 24VDC/7Amp 10Amp Power Supply Dimensions mm (in.) 125 (4.92) 230VAC 115VAC 8708680000 CP SNT 250W 24V 10A 8710620000 CP DM 10 12 VDC 6A Description Part No. 1105430000 12 VDC 12 A 1105440000 Description 24 VDC 3.8 A Part No. 1105790000 Description 24 VDC 7.5 A Approvals - See table at right Approvals - See table at right Approvals - See table at right 48V 4 A L x W x H: 110 x 35 x 110 mm (4.33 x 1.38 x 4.33 in) L x W x H: 110 x 54 x 110 mm (4.33 x 2.12 x 4.33 in) L x W x H: 110 x 35 x 110 mm (4.33 x 1.38 x 4.33 in) Approvals - See table at right CP T SNT 360W 55.5 (2.19) 110 (4.33) N PE 12 11 14 +V Description Part No. Description Part No. v file E236157 \ Listed to UL508, CSA C22.2 No. 14 1105810000 24 VDC 15 A 1105820000 24 VDC 25 A 1105840000 v file E255651 { to ANSI/UL60950, CSA60950 1105850000 48V 7.5 A 1105860000 Approvals - See table at right L x W x H: 125 x 80 x 125 mm (4.92 x 3.15 x 4.92 in) 48V 12.5 A 1105870000 r file 246286 r to C22.2 No. 107.1 Approvals - See table at right r file 246286 C LxWxH: 125 x 165 x 125 mm (4.92 x 6.5 x 4.92 in) r file 246286 r file 246286 • DC-OK signal and external shut down function US C US C US C1D2 to C22.2 No. 213, UL1604, Group A, B, C, D C1Z2 to CSA60079-15, UL60079-15 & ANSI/ISA 12.012.01, Ex nC IIC T4U, Aex nC IIC T4U IEC file SI-1729 B3 % marked • Operating temperature range of -25°C to +70°C LCIE file 10 ATEX 1015U T to EN60079-0, EN60079-15 (Ex nAC IIC T4 or T5 • MTBF > 900,000 Hours Output 24V=20A 8708680000 CP SNT 250W 24V 10A -V -V E1 -V -V E2 L 24VDC/3.5Amp N PE 12 11 14 +V +V -V -V 24VDC/3.5Amp Status Relays (Change-Over-Contact) e.g. to PLC, IPC or Fieldbus • Diode modules provide galvanic isolation between power supplies 03. UNINTERRUPTED DC POWER WITH REDUNDANCY AND FAULT INDICATION • Use status relays for remote alarm indication Increase DC Power Delivery to Control Systems (this example supplying 14A to load) Diode Module 24VDC/14Amp CP T RM 20* Description Part No. 2 x 24 VDC input 15A 1105880000 Description % \ T Dimensions mm (in.) Dimensions mm (in.) 110 (4.33) 110 (4.33) 110 (4.33) -V -V 230VAC 115VAC 115VAC 8708680000 CP SNT 250W 24V 10A 1105890000 8710620000 CP DM 10 Input 24V=2x10A Output 24V=20A 8708680000 CP SNT 250W 24V 10A DC OK N PE 12 11 14 +V DC OK +V -V E1 -V -V -V E2 L N PE 12 11 14 +V +V -V -V IN 24VDC/7Amp 24VDC/7Amp Status Relays (Change-Over-Contact) e.g. to PLC, IPC or Fieldbus 110 (4.33) 35 (2.19) +V 230VAC Part No. 2 x Control input 25A % \ T 10Amp Power Supply OUT +V L to CSA60950, ANSI/UL60950 • Output voltages of 12, 14 and 48VDC 24V=2x10A DC OK +V 55.5 (2.19) PRO-M Approvals Part No. L x W x H: 110 x 54 x 110 mm (4.33 x 2.12 x 4.33 in) • Cold start-up at full load at -25°C CP T SNT 600W PRO-H Part No. CP T SNT 180W Input IN Advanced Description CP T SNT 90W -V 115VAC L CP T RM 10* CP T SNT 140W -V 230VAC 10Amp Power Supply CP T SNT 70W +V DC OK 110 (4.33) SINGLE-PHASE 120/230VAC 10Amp Power Supply OUT ECO • Operating temperature range of -20°C to +50°C • cULus to UL 508 and CSA C22.2 No.107.1 8768650000 Status Relays (Change-Over-Contact) e.g. to PLC, IPC or Fieldbus • Option for connecting in parallel • Operating temperature range of -10°C to +55°C, model dependent Part No. 20 A per input 125 (4.92) LxWxH: 90 x 18 x 112.5 mm (3.54 x 0.71 x 4.43 in) • LED status indicator • Status relay outputs 8710620000 Description +V • Output voltage adjustable via potentiometer • Flexibility of wide range of output current from 3 Amps to 40 Amps 10 A per input Dimensions mm (in.) CP SNT 12W Description Part No. % \ SINGLE-PHASE 120/230VAC CP SNT3 120W Description %\ to UL508A, rC22.2 no.107.1 380/480VAC Description 24VDC/10Amp • The amount of power needed is provided by two power supplies combined in parallel CP DM 20 Advanced SINGLE-PHASE 120/230VAC • 125% power boost feature for high inrush applications Input 24VDC/10Amp CP DM 10 • cULus to UL 508 and CSA C22.2 No.107.1 • Class 1, Division 2 approvals -V IN • MTBF > 500,000 Hours PRO-H -V DC OK • Operating temperature range of -25°C to +70°C • Provide a cost-effective power delivery solution for basic requirements +V 230VAC 8708680000 CP SNT 250W 24V 10A • 120% power boost feature for high inrush applications • Ideal for OEMs, panel shops, and control manufacturing 10Amp Power Supply OUT +V 115VAC • Single-phase and three-phase versions, from 70 W to 1000 W ECO 24VDC/20Amp 10Amp Power Supply PRO-M SINGLE-PHASE 120/230VAC Status Relays (Change-Over-Contact) e.g. to PLC, IPC or Fieldbus 04. INCREASED DC POWER DELIVERY TO CONTROL SYSTEMS • The amount of power needed is provided by two power supplies combined in parallel • Use status relays for remote alarm indication 54 (2.12) * Only these diode modules carry a hazardous approval rating. with derating) For Larger Inputs • Load sharing capability • 200% of maximum rated output for a specified amount of time (power boost) • Available with low residual ripple (< 10mV in some cases) • Single-phase and three-phase versions Description 24…28 VDC 2.3 A 48 VDC 1.04 A 12…15 VDC 3 A 5 VDC 3 A CP SNT 160W Part No. 9927480024* 9927480048 9927480012* 9927480005 Description 24…28 VDC 6.5 A 5 VDC 10 A 48 VDC 3.25 A 9.5…15 VDC 10 A CP SNT 300W Part No. 9925340024* 9925340005 9925340048* 9925340012 r % v r % v L x W x H: 57 x 98 x 131 mm (2.24 x 3.86 x 5.16 in) L x W x H: 57 x 127 x 175 mm (2.24 x 5.0 x 6.89 in) • Many available in 5, 12, 24, 28, and 48V versions Description CP SNT 55W Part No. Description CP SNT 160W Part No. Description 22…28 VDC 12.5 A 9916250024 r % v r Class 1, Div. 2 24 VDC 2.3 A r% \ r% \ L x W x H: 240 x 104 x 155 mm (9.45 x 4.09 x 6.10 in) L x W x H: 60 x 108 x 168 mm (2.36 x 4.25 x 6.61 in) L x W x H: 58.4 x 138.2 x 177.8 mm (2.3 x 5.44 x 7.0 in) 9917790324 24…28 VDC 6.5 A Part No. 9925340324 INSTAPOWER CP SNT 24W • Flexibility with a wide-range of AC and DC input • Output voltage adjustable via potentiometer • LED status indicator • Option for connecting in parallel • Operating temperature range of -20°C to +50°C, model dependent • Rugged housing can be panel mounted • International approvals for use world-wide • Operating temperature range of -20°C to +50°C, model dependent • Available with status relay and analog outputs for monitoring CP SNT 25W Description Part No. 24 VDC 1 A 9928890024 4…8 VDC 5 A Part No. 8754960000 Description -V -V Critical Loads Diode Module 24VDC/10Amp 115VAC 8708680000 CP SNT 250W 24V 10A Part No. 9…15 VDC 4 A 8754970000 28 VDC 1 A 9928890028 r, %, v 508, { 60950, GS Class 2 15…28 VDC 2A 8739140000 9928890015 LxWxH: 70 x 90.5 x 62.5 mm (2.76 x 3.56 x 2.46 in) 46…55 VDC 1A 8879230000 12 VDC 1.5 A 9928890012 r, %, v 508, { 60950, GS Class 2 5 VDC 2 A 9928890005 LxWxH: 70 x 90.5 x 62.5 mm (2.76 x 3.56 x 2.46 in) 8710620000 CP DM 10 Input 24V=2x10A Output 24V=20A Status Relays (Change-Over Contact) e.g. to PLC, IPC or Fieldbus DC OK Non-critical Loads CP DM 30 and 9928890024, v 1310 (Class 2) for 9928890024 Part No. CP DM 30 with voltage sensing and fault relay CP DM 30 without voltage sensing LxWxH: 52 x 90.5 x 62.5 mm (2.05 x 3.56 x 2.46 in) Description Dimensions mm (in.) 9987390000 20 A per input (2 x 20) max. 7940005219 9987860000 40 A per input (1 x 40) max. 7940005218 110 (4.33) 99 (3.90) 109.2 (4.30) PE 12 11 14 +V +V -V E1 -V -V -V E2 IN 12 11 10 V+ V+ V- V- DC OK 8703660000 CP SNT 70A 24V 3A Dimensions mm (in.) 155 (6.10) N Part No. \ va L 24VDC/10Amp Status Relays (Change-Over Contact) e.g. to PLC, IPC or Fieldbus RSD 40 Description 70 (2.75) *r Class 1, Div. 2 +V 230VAC 15 VDC 1.5 A r, v 508 Listed, % r Class 1 Div. 2 and Zone 2 for 9928890012 OUT +V CP SNT 48W Description 24VDC/3Amp 10Amp Power Supply 24VDC/10Amp ECO CP SNT 55W SINGLE-PHASE 120/230VAC PRO-H Advanced THREE-PHASE 380/480VAC Advanced SINGLE-PHASE 120/230VAC PRO-M Guarantee DC Power to Critical Loads (this example supplying 3A to critical load) 109.2 (4.30) 24Amp Power Supply 24VDC/3Amp L N PE • Under normal operating conditions, the critical load is provided by both the 05. GUARANTEE DC POWER TO CRITICAL LOADS 10A and 3A power supply • If the larger power supply fails, the critical load will continue to be maintained by the 3A power supply • This ensures uninterrupted power to the critical load Note: Two power supplies in parallel must be calibrated to within ± 50 mv of each other.