Datasheet PRO-H Series Single-Phase Power Supplies NEW DC-OK signal and external shut down function. Redundant operation with true power sharing is available as an option. The PRO-H Series power supplies comply with the latest safety and EMC standards for industrial environments. The PRO-H Series is a new generation of high performance DIN-rail mounted single-phase power supplies designed to work reliably even under demanding factory floor conditions. A high power reserve guarantees reliable start-up of loads with high inrush currents. Excellent electrical specifications and high immunity against fluctuations on input voltage makes these compact modules the best choice to power sensitive loads in industrial process control systems, machine tools or other demanding industrial applications. The PRO-H Series offers users easy installation with detachable screw terminal block and snap-on mounting on DIN-rails. All models offer a Weidmuller, Canada 10 Spy Court Markham, Ontario L3R 5H6 Telephone: (800) 268-4080 Facsimile: (877) 300-5635 Email: [email protected] Website: www.weidmuller.ca Weidmuller, Mexico Blvd. Hermanos Serdán 698, Col. San Rafael Oriente Puebla, Puebla, Mexico C.P. 72029 Telephone: 01 222 2686267 Facsimile: 01 222 2686219 Email: [email protected] Website: www.weidmuller.com.mx • Hazardous approvals for process automation applications • Industrial grade design • Rugged metal case for harsh industrial environments • Autoselect input and international safety approvals • Industrial operating temperature range: –25°C to +70°C (Cold start at full load at -25°C) • Variable output voltage • Indefinite short circuit, overvoltage and overtemperature protection • Power OK signal • Remote On/Off • Shock and vibration proof • Optional panel mounting • Redundancy module Weidmuller, United States 821 Southlake Blvd. Richmond, Virginia 23236 Telephone: (800) 849-9343 Facsimile: (804) 379-2593 Email: [email protected] Website: www.weidmuller.com PRO-H SERIES Single-Phase Power Supplies CP T SNT 70W 12V 6A L (+) N(- CP T SNT 90W 24V 3.8A + AC PE CP T SNT 140W 12V 12A DC - Technical Data Input Specifications Input voltage Input voltage range Input voltage frequency Harmonic limits Hold up time Inrush current Recommended Circuit breaker, Curve 1 or fuse, slow blow type Efficiency Output Specifications Output voltage Output voltage adj. range Output current Output power max. Regulation – Input variation – Load variation (10–100 %) Ripple and Noise (20MHz Bandwidth) Electronic short circuit protection Output overvoltage protection Overload protection Overtemperature protection Status indicator Power OK signal – trigger threshold: – active output signal: (reference to –Vout) – relay output General Specifications Operating temperature range Cooling Mounting Storage temperature Humidity (non condensing) Pollution degree Temperature coefficient Reliability, calculated MTBF @ 25°C acc. to IEC 61709 Remote On/Off (See LIT0917 - Installation Instructions) Isolation Environment – Vibration acc. IEC 60068-2-6; – Shock acc. IEC 60068-2-27 Dimension (W x D x H) Clearances – Above/Below – Sides Weight Approvals 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC)* 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <12A @ 115VAC; <20A @ 230VAC 6A 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC)* 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <13A @ 115VAC; <25A @ 230VAC 6A 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC)* 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <12A @ 115VAC; <20A @ 230VAC 6A 87% typ. 87% typ. 87% typ. 12 VDC 12-14 VDC 6.5A 70W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 20V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 9–11 V 11.0 V ±1.0 V (20 mA max.) rated: 30 VDC/1.0 A 12 VDC 12-14 VDC 13.0A 140W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 20V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 9–11 V 11.0 V ±1.0 V (20 mA max.) rated: 30 VDC/1.0 A 24 VDC 24-28 VDC 3.75A 90W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 35V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 18-22 V 22.0 V ±2.0 V (10 mA max.) rated: 30 VDC/1.0 A –25 °C to +70 °C max. (–13 °F to +158°F)** convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >1.8 Million hours, max. load –25 °C to +70 °C max. (–13 °F to +158°F)** convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >1.2 Million hours, max. load –25 °C to +70 °C max. (–13 °F to +158°F)** convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >1.8 Million hours, max. load by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 35 x 110 x 110 mm 80 mm (3.15 in) 10 mm (0.39 in) 0.5kg by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 54 x 110 x 110 mm 80 mm (3.15 in) 10 mm (0.39 in) 0.7kg by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 35 x 110 x 110 mm 80 mm (3.15 in) 10 mm (0.39 in) 0.5kg See Approvals Table, page 6 See Approvals Table, page 6 See Approvals Table, page 6 Ordering Data Type CP T SNT 70W 12V 6A * See Graph B, page 8 **See Graph A, page 8 2 Part No. 1105430000 Type CP T SNT 140W 12V 12A Part No. 1105440000 Type CP T SNT 90W 24V 3.8A Part No. 1105790000 Single-Phase Power Supplies PRO-H SERIES CP T SNT 180W 24V 7.5A L (+) N(- CP T SNT 600W 24V 25A + AC PE CP T SNT 360W 24V 15A DC - Technical Data Input Specifications Input voltage Input voltage range Input voltage frequency Harmonic limits Hold up time Inrush current Recommended Circuit breaker, Curve 1 or fuse, slow blow type Efficiency Output Specifications Output voltage Output voltage adj. range Output current Output power max. Regulation – Input variation – Load variation (10–100 %) Ripple and Noise (20MHz Bandwidth) Electronic short circuit protection Output overvoltage protection Overload protection Overtemperature protection Status indicator Power OK signal – trigger threshold: – active output signal: (reference to –Vout) – relay output General Specifications Operating temperature range Cooling Mounting Storage temperature Humidity (non condensing) Pollution degree Temperature coefficient Reliability, calculated MTBF @ 25°C acc. to IEC 61709 Remote On/Off (See LIT0917 - Installation Instructions) Isolation Environment – Vibration acc. IEC 60068-2-6; – Shock acc. IEC 60068-2-27 Dimension (W x D x H) Clearances – Above/Below – Sides Weight Approvals 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC)* 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <13A @ 115VAC; <25A @ 230VAC 6A 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC)* 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <16A @ 115VAC; <25A @ 230VAC 10A 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC)* 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <25A @ 115VAC; <30A @ 230VAC 15A 87% typ. 87% typ. 87% typ. 24 VDC 24-28 VDC 7.5A 180W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 35V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 18-22 V 22.0 V ±2.0 V (20 mA max.) rated: 30 VDC/1.0 A 24 VDC 24-28 VDC 15A 360W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 35V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 18-22 V 22.0 V ±2.0 V (20 mA max.) rated: 30 VDC/1.0 A 24 VDC 24-28 VDC 25A 600W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 35V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 18-22 V 22.0 V ±2.0 V (20 mA max.) rated: 30 VDC/1.0 A –25 °C to +70 °C max. (–13 °F to +158°F)** convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >0.9 Million hours, max. load –25 °C to +70 °C max. (–13 °F to +158°F)** convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >0.9 Million hours, max. load –25 °C to +70 °C max. (–13 °F to +158°F)** convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >0.9 Million hours, max. load by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 54 x 110 x 110 mm 80 mm (3.15 in) 10 mm (0.39 in) 0.7kg by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 80 x 125 x 125 mm 80 mm (3.15 in) 10 mm (0.39 in) 1.1kg by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 165 x 125 x 125 mm 80 mm (3.15 in) 10 mm (0.39 in) 2.8kg See Approvals Table, page 6 See Approvals Table, page 6 See Approvals Table, page 6 Ordering Data Type CP T SNT 180W 24V 7.5A Part No. 1105810000 Type CP T SNT 360W 24V 15A Part No. 1105820000 Type CP T SNT 600W 24V 25A Part No. 1105840000 * See Graph B, page 8 **See Graph A, page 8 3 PRO-H SERIES Single-Phase Power Supplies CP T SNT 180W 48V 4A L (+) N(- CP T SNT 600W 48V 12.5A + AC PE CP T SNT 360W 48V 7.5A DC - Technical Data Input Specifications Input voltage Input voltage range Input voltage frequency Harmonic limits Hold up time Inrush current Recommended Circuit breaker, Curve 1 or fuse, slow blow type Efficiency Output Specifications Output voltage Output voltage adj. range Output current Output power max. Regulation – Input variation – Load variation (10–100 %) Ripple and Noise (20MHz Bandwidth) Electronic short circuit protection Output overvoltage protection Overload protection Overtemperature protection Status indicator Power OK signal – trigger threshold: – active output signal: (reference to –Vout) – relay output General Specifications Operating temperature range Cooling Mounting Storage temperature Humidity (non condensing) Pollution degree Temperature coefficient Reliability, calculated MTBF @ 25°C acc. to IEC 61709 Remote On/Off (See LIT0917 - Installation Instructions) Isolation Environment – Vibration acc. IEC 60068-2-6; – Shock acc. IEC 60068-2-27 Dimension (W x D x H) Clearances – Above/Below – Sides Weight Approvals 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC)* 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <13A @ 115VAC; <25A @ 230VAC 6A 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC)* 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <16A @ 115VAC; <25A @ 230VAC 10A 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC)* 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <25A @ 115VAC; <30A @ 230VAC 15A 87% typ. 87% typ. 87% typ. 48 VDC 48-56 VDC 4.0A 180W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 60V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 36-46 V 44.0 V ±4.0 V (15 mA max.) rated: 48 VDC/0.5 A 48 VDC 48-56 VDC 7.5A 360W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 60V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 36-46 V 44.0 V ±4.0 V (15 mA max.) rated: 48 VDC/0.5 A 48 VDC 48-56 VDC 12.5A 600W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 60V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 36-46 V 44.0 V ±4.0 V (15 mA max.) rated: 48 VDC/0.5 A –25 °C to +70 °C max. (–13 °F to +158°F)** convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >0.9 Million hours, max. load –25 °C to +70 °C max. (–13 °F to +158°F)** convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >0.9 Million hours, max. load –25 °C to +70 °C max. (–13 °F to +158°F)** convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >0.9 Million hours, max. load by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 54 x 110 x 110 mm 80 mm (3.15 in) 10 mm (0.39 in) 0.7kg by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 80 x 125 x 125 mm 80 mm (3.15 in) 10 mm (0.39 in) 1.1kg by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 165 x 125 x 125 mm 80 mm (3.15 in) 10 mm (0.39 in) 2.8kg See Approvals Table, page 6 See Approvals Table, page 6 See Approvals Table, page 6 Ordering Data Type CP T SNT 180W 48V 4A * See Graph B, page 8 **See Graph A, page 8 4 Part No. 1105850000 Type CP T SNT 360W 48V 7.5A Part No. 1105860000 Type CP T SNT 600W 48V 12.5A Part No. 1105870000 Single-Phase Power Supplies PRO-H SERIES CP T RM 10 Redundancy Module Redundancy Modules With a redundancy module and two PRO-H Series power supplies (of same type) you can configure a highly reliable, truly redundant power system without any additional components. This module enforces the equivalent sharing of the output current by each power supply. The system is fully redundant and provides output power even if one power supply has completely failed e.g. by short circuit on the output. In the event that either power supply fails or is disconnected, the second unit will automatically supply the full current to the load. The redundancy of the system is monitored and if lost, indicated by an alarm output. The inputs are hot swappable and can be loaded up to 15 A each. CP T RM 20 Redundancy Module Technical Data Input Specifications Input Input current Output Specifications Output voltage Output voltage adj. range Output power max. Output current General Data Status indicator Operating temperature Redundancy OK signal (Alarm) MTBF in acc. To IEC 61709 Alarm relay contact Environment - Vibration - Shock Dimension (W x D x H) Weight Remote link cable (0.5m) Remote On/Off Approvals 2 x 24 VDC 15A 2 x Control Input 25A 24 VDC 24-27 VDC 360 W 15A @ 24VDC, @ 40°C 24 VDC 24-27 VDC 600 W 25A @ 24VDC, @ 40°C LED – 25 °C to 70 °C max. (–13 °F...+158 °F) derating above 40 °C (104 °F): 1.5 %/K trigger threshold at 18...22VDC, contact open if both inputs failed >350,000 hours, max. load 30VDC/1A 3 axis, sine sweep, 10…55Hz, 1g, 1oct/min. 3 axis, 15g half sine, 11ms 35 x 110 x 110 mm 0.5kg 2 cables included by ext. contact: contact open = On, contact closed = Off LED – 25 °C to 70 °C max. (–13 °F...+158 °F) derating above 40 °C (104 °F): 1.5 %/K trigger threshold at 18...22VDC, contact open if both inputs failed >350,000 hours, max. load 3 axis, sine sweep, 10…55Hz, 1g, 1oct/min. 3 axis, 15g half sine, 11ms 54 x 110 x 110 mm 0.7kg 2 cables included by ext. contact: contact open = On, contact closed = Off See Approvals Table, page 6 See Approvals Table, page 6 Ordering Data Type CP T RM 10 Function Diagram Part No. 1105880000 + TSP J1.2 J1.1 J2 J2.3 J2.4 + J2.1 J2.2 _ Bottom view Output Load Output Remote Link 1 1 2 1 2 Volt adjust DC IN 2_ J1.4 Power Supplies Remote Link 2 J4 J3 J1.3 J4.1 TSP Top view 1 2 3 4 J3.1 J3.2 + Part No. 1105890000 Connector Positions Front view DC IN 1_ Type CP T RM 20 J5 REM Controller J4.2 1 DC IN 1 DC IN 2 J5.1 Alarm Redundancy ok J5.2 J5.3 2 3 4 J5.4 J1 Remote On/Off 1 2 3 4 J1 For detailed installation instructions, please visit www.weidmuller.com/power_supplies and download LIT0917 Pin 1 Pin 2 Pin 3 Pin 4 Input 1 Input 1 Input 2 Input 2 J2 -Vin +Vin -Vin +Vin GND (-) GND (-) Vout (+) Vout (+) J3 Voltage Control 1 For Input 1 S+ S- J4 Voltage Control 2 For Input 2 S+ S- J5 DC-OK Signal DC-OK Relay Contact Remote ON/OFF Remote ON/OFF 5 PRO-H SERIES IEC file SI-1729 B3 LCIE file 10 ATEX 1015U cULus Listed to UL508, CSA C22.2 No. 14 cRUus to ANSI/UL60950, CSA60950 CSA to C22.2 No. 107.1 cCSAus to CSA60950, ANSI/UL60950 cCSAus C1D2 to C22.2 No. 213, UL1604, Group A, B, C, D cCSAus C1Z2 to CSA60079-15, UL60079-15 & ANSI/ISA 12.012.01, Ex nC IIC T4U, Aex nC IIC T4U CE marked to EN60079-0, EN60079-15 (Ex nAC IIC T4 or T5 with derating) 35.0 CP T SNT 70W 12V 6A CP T SNT 90W 24V 3.8A (1.38) 5.0 12345 (0.20) Agency Approvals UL file E236157 UL file E255651 CSA file 246286 CSA file 246286 CSA file 246286 CSA file 246286 Single-Phase Power Supplies 25.0 5.0 (0.98) (0.20) 110.0 (4.33) 110.0 (4.33) 38.5 (1.52) J2 DC OK Weight: 0.5kg (1.0lb) DC ON O/P ADJ. (3.15) 3 2 1 1 2 P/S P S 80.0 110.0 (4.33) J4 J3 Remote PE N L J1 1 2 3 J1 Earth Neutral Live - 54.0 J3 S+ S- J4 Normal Mode Common Parallel Mode - (2.13) 1 2 3 4 56 7 5.0 CP T SNT 140W 12V 12A CP T SNT 180W 24V 7.5A CP T SNT 180W 48V 4A J2 GND (-) Vout (+) DC-OK Signal DC-OK Relay Contact 1 DC-OK Relay Contact 2 (0.20) Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 25.0 14.5 (0.98) (0.57) 38.5 (1.52) J2 DC OK DC ON O/P ADJ. PE N J4 Remote P/S 1 2 3 80.0 2 S P 110.0 J3 1 (3.15) (4.33) Weight: 0.7kg (1.4lb) L J1 1 2 3 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Dimensions in [mm], ( ) = inch Tolerances: ±0.5 mm (±0.02) 6 J1 Earth Neutral Live - J2 GND (-) GND (-) Vout (+) Vout (+) DC-OK Signal DC-OK Relay Contact 1 DC-OK Relay Contact 2 J3 S+ S- J4 Normal Mode Common Parallel Mode - For detailed installation instructions, please visit www.weidmuller.com/power_supplies and download LIT0917 Single-Phase Power Supplies PRO-H SERIES 80.0 CP T SNT 360W 24V 15A CP T SNT 360W 48V 7.5A (3.15) 46.0 17.0 5.0 1 2 3 4 56 7 (0.20) (1.81) (0.67) 25.0 25.0 (0.98) (0.98) J2 Weight: 1.1kg (2.4lb) DC OK DC ON 125.0 (4.92) O/P ADJ. J3 1 PE N 2 Remote 3 2 1 L J4 J1 125.0 (4.92) (1.77) 1 2 3 J3 S+ S- J4 Normal Mode Common Parallel Mode - CP T SNT 600W 24V 24A CP T SNT 600W 48V 12.5A 45.0 J2 GND (-) GND (-) Vout (+) Vout (+) DC-OK Signal DC-OK Relay Contact 1 DC-OK Relay Contact 2 (3.41) J1 Earth Neutral Live - 86.5 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 321 2 1 165.0 1 2 J4 3 J3 123 J5 J1 1 2 3 (6.50) 4 J2 P/S (4.92) Weight: 2.8kg (6.0lb) Remote 125.0 P S DC ON DC OK PE N L J5 1 2 3 J2 1 2 3 4 J1 1 2 3 25.0 O/P ADJ. 25.0 (0.98) (0.98) 21.0 (4.84) (0.83) 125.0 (4.92) J1 J2 J3 J4 J5 Earth Neutral Live - GND (-) GND (-) Vout (+) Vout (+) S+ S- Normal Mode Common Parallel Mode - DC-OK Relay Contact 1 DC-OK Relay Contact 2 DC-OK Signal - 86.5 Pin 1 Pin 2 Pin 3 Pin 4 (3.41) 45.0 (1.77) 123.0 Dimensions in [mm], ( ) = inch Tolerances: ±0.5 mm (±0.02) For detailed installation instructions, please visit www.weidmuller.com/power_supplies and download LIT0917 7 PRO-H SERIES Single-Phase Power Supplies Power Supplies Output Power Derating A) Wall Mounting Bracket Output Power Derating vs Ambient Temperature Ordering Data 1129210000 1129220000 100 90 Type CP MB01 CP MB02 For Models CP T SNT 70W, 90W, 140W, 180W CP T SNT 360W, 600W Content of Kit 1 bracket type A 2 brackets type B 70 TSP 070 TSP 140 TSP 090 TSP 180 TSP 360 60 50 CP T SNT 70W, 90W 85.0 (3.35) Type A: 42.5 (1.67) 60 34.5 (1.36) 70 ø 4.3 (0.17) ø 4.3 (0.17) ø 4.3 (0.17) B) 34.5 (1.36) Output Power Derating vs Input Voltage 55.0 (2.16) 40 50 Temperature [˚C] 31.0 (5.06) 40 -25 2.0 (0.08) Output Power [% Pmax] TSP 600 80 100 80 CP T SNT 140W, 180W 4 x positioning holes 70 60 50 7.0 (0.28) Output Power [% Pmax] 90 15.0 40 132 Input Voltage [VAC] 18 7 2 30 264 (0.59) 15.0 (0.59) 55.0 (2.16) 85 90 100 110 115 Material: 2 mm Mild Steel Tolerance: ±0.1mm (± 0.004) Trip Curve 1000 Operating Characteristics Curve 1 Ambient Temperature 30°C CP T SNT 360W 46.0 (1.81) Type B: 33.0 (1.30) 96.0 (3.78) 10 25 (0.98) 2.0 (0.08) Tripping Time Minutes 100 1 0.1 ø 4.3 (0.17) 50.0 (1.97) 30.0 (1.18) Seconds 1 62.5 (2.46) 10 2x ø4.3 (0.17) 4000 5000 2000 2500 3000 1500 1000 400 500 300 100 105 130 150 200 0.001 2.0 (0.08) 0.01 CP T SNT 600W 4 x positioning holes (%) Rated Current 62.5 (2.46) (0.59) 7.0 (0.28) 173.0 (6.81) 15.0 Material: 2 mm Mild Steel Tolerance: ±0.1mm (± 0.004) Dimensions: [mm] ( ) = Inch For detailed installation instructions, please visit www.weidmuller.com/power_supplies and download LIT0917 8 Subject to technical changes • 10/11-2.5M-LIT0909