NEW PRO-H Series—Single Phase Input Supplies CP T SNT 180W 24V 7.5A L (+) N(- CP T SNT 600W 24V 25A + AC PE CP T SNT 360W 24V 15A DC - Ordering Data Technical Data Input Specifications Input voltage Input voltage range Input voltage frequency Harmonic limits Hold up time Inrush current Recommended Circuit breaker, Curve 1 or fuse, slow blow type Efficiency Output Specifications Output voltage Output voltage adj. range Output current Output power max. Regulation – Input variation – Load variation (10–100 %) Ripple and Noise (20MHz Bandwidth) Electronic short circuit protection Output overvoltage protection Overload protection Overtemperature protection Status indicator Power OK signal – trigger threshold: – active output signal: (reference to –Vout) – relay output General Specifications Operating temperature range Cooling Mounting Storage temperature Humidity (non condensing) Pollution degree Temperature coefficient Reliability, calculated MTBF @ 25°C acc. to IEC 61709 Remote On/Off (See LIT0917 - Installation Instructions) Isolation Environment – Vibration acc. IEC 60068-2-6 – Shock acc. IEC 60068-2-27 Dimension (W x D x H) Clearances – Above /Below – Sides Weight Approvals Type CP T SNT 180W 24V 7.5A Part No. 1105810000 Type CP T SNT 360W 24V 15A Part No. 1105820000 Type CP T SNT 600W 24V 25A Part No. 1105840000 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC) 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <13A @ 115VAC; <25A @ 230VAC 6A 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC) 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <16A @ 115VAC; <25A @ 230VAC 10A 115VAC/230VAC autoselect 85-132/187-264 VAC autoselect (output current derating below 100VAC) 47Hz - 63Hz EN 61000-3-2, Class A (for limited output power) 20ms min. 115/230 VAC <25A @ 115VAC; <30A @ 230VAC 15A 87% typ. 87% typ. 87% typ. 24 VDC 24-28 VDC 7.5A 180W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 35V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 18-22 V 22.0 V ±2.0 V (20 mA max.) rated: 30 VDC/1.0 A 24 VDC 24-28 VDC 15A 360W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 35V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 18-22 V 22.0 V ±2.0 V (20 mA max.) rated: 30 VDC/1.0 A 24 VDC 24-28 VDC 25A 600W 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Current limitation at Imax., constant current, automatic recovery 35V electronic overload protection Switch off at overtemperature, automatic restart Dual color LED (green: DC ok; red: DC off) 18-22 V 22.0 V ±2.0 V (20 mA max.) rated: 30 VDC/1.0 A –25 °C to +70 °C max. (–13 °F to +158°F) convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >0.9 Million hours, max. load –25 °C to +70 °C max. (–13 °F to +158°F) convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >0.9 Million hours, max. load –25 °C to +70 °C max. (–13 °F to +158°F) convection cooling, no internal fan TS35 DIN-rail (Horizontal) to allow for cooling –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K >0.9 Million hours, max. load by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 54 x 110 x 110 mm 80 mm (3.15 in) 10 mm (0.39 in) 0.7kg by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 80 x 125 x 125 mm 80 mm (3.15 in) 10 mm (0.39 in) 1.1kg by ext. contact. DC on: -S contact open DC off: -S connected via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms 165 x 125 x 125 mm 80 mm (3.15 in) 10 mm (0.39 in) 2.8kg UL file E236157 cULus Listed to UL508, CSA C22.2 No. 14 UL file E255651 cRUus to ANSI/UL60950, CSA60950 CSA file 246286 CSA to C22.2 No. 107.1 CSA file 246286 cCSAus to CSA60950, ANSI/UL60950 CSA file 246286 cCSAus C1D2 to C22.2 No. 213 UL1604, Group A, B, C, D CSA file 246286 cCSAus C1Z2 to CSA60079-15 & ANSI/ISA 12.012.01, Ex nC IIC T4U, Aex nC IIC T4U IEC file SI-1729 B3, CE marked LCIE file 10, ATEX 1015 U EN60079-0, EN60079-15 (Ex nAC IIC T4 or T5 with derating) II 3G Ex nA nC IIC t4 Gc UL file E236157 cULus Listed to UL508, CSA C22.2 No. 14 UL file E255651 cRUus to ANSI/UL60950, CSA60950 CSA file 246286 CSA to C22.2 No. 107.1 CSA file 246286 cCSAus to CSA60950, ANSI/UL60950 CSA file 246286 cCSAus C1D2 to C22.2 No. 213 UL1604, Group A, B, C, D CSA file 246286 cCSAus C1Z2 to CSA60079-15 & ANSI/ISA 12.012.01, Ex nC IIC T4U, Aex nC IIC T4U IEC file SI-1729 B3, CE marked LCIE file 10, ATEX 1015 U EN60079-0, EN60079-15 (Ex nAC IIC T4 or T5 with derating) II 3G Ex nA nC IIC t4 Gc UL file E236157 cULus Listed to UL508, CSA C22.2 No. 14 UL file E255651 cRUus to ANSI/UL60950, CSA60950 CSA file 246286 CSA to C22.2 No. 107.1 CSA file 246286 cCSAus to CSA60950, ANSI/UL60950 CSA file 246286 cCSAus C1D2 to C22.2 No. 213 UL1604, Group A, B, C, D CSA file 246286 cCSAus C1Z2 to CSA60079-15 & ANSI/ISA 12.012.01, Ex nC IIC T4U, Aex nC IIC T4U IEC file SI-1729 B3, CE marked LCIE file 10, ATEX 1015 U EN60079-0, EN60079-15 (Ex nAC IIC T4 or T5 with derating) II 3G Ex nA nC IIC t4 Gc 29 NEW PRO-H Series—Diode Modules for Redundancy Redundancy Modules CP T RM 10 Redundancy Module With a redundancy module and two PRO-H Series power supplies (of same type) you can configure a highly reliable, truly redundant power system without any additional components. This module enforces the equivalent sharing of the output current by each power supply. The system is fully redundant and provides output power even if one power supply has completely failed e.g. by short circuit on the output. In the event that either power supply fails or is disconnected, the second unit will automatically supply the full current to the load. The redundancy of the system is monitored and if lost, indicated by an alarm output. The inputs are hot swappable and can be loaded up to 15A each. CP T RM 20 Redundancy Module Technical Data Input Specifications Input Input current Output Specifications Output voltage Output voltage adj. range Output power max. Output current General Data Status indicator Operating temperature Redundancy OK signal (Alarm) MTBF in acc. To IEC 61709 Alarm relay contact Environment - Vibration - Shock Dimension (W x D x H) Weight Remote link cable (0.5m) Remote On/Off 2 x 24 VDC 15A 2 x Control Input 25A 24 VDC 24-27 VDC 360 W 15A @ 24VDC, @ 40°C 24 VDC 24-27 VDC 600 W 25A @ 24VDC, @ 40°C LED – 25 °C to 70 °C max. (–13 °F...+158 °F) derating above 40 °C (104 °F): 1.5 %/K trigger threshold at 18...22VDC, contact open if both inputs failed >350,000 hours, max. load 30VDC/1A 3 axis, sine sweep, 10…55Hz, 1g, 1oct/min. 3 axis, 15g half sine, 11ms 35 x 110 x 110 mm 0.5kg 2 cables included by ext. contact: contact open = On, contact closed = Off LED – 25 °C to 70 °C max. (–13 °F...+158 °F) derating above 40 °C (104 °F): 1.5 %/K trigger threshold at 18...22VDC, contact open if both inputs failed >350,000 hours, max. load 3 axis, sine sweep, 10…55Hz, 1g, 1oct/min. 3 axis, 15g half sine, 11ms 54 x 110 x 110 mm 0.7kg 2 cables included by ext. contact: contact open = On, contact closed = Off II 3G Ex nA nC IIC t4 Gc Approvals II 3G Ex nA nC IIC t4 Gc Ordering Data Type CP T RM 10 Function Diagram Part No. 1105880000 + TSP J1.2 J1.1 J2 J2.3 J2.4 + J2.1 J2.2 _ Bottom view Output Load Output Remote Link 1 1 2 1 2 Volt adjust DC IN 2_ J1.4 Power Supplies Remote Link 2 J4 J3 J1.3 J4.1 TSP Top view 1 2 3 4 J3.1 J3.2 + Part No. 1105890000 Connector Positions Front view DC IN 1_ Type CP T RM 20 J5 REM Controller J4.2 1 DC IN 1 DC IN 2 J5.1 Alarm Redundancy ok J5.2 J5.3 2 3 4 J5.4 J1 Remote On/Off 1 2 3 4 J1 For detailed installation instructions, please visit www.weidmuller.com/power_supplies and download LIT0917 Pin Pin Pin Pin 1 2 3 4 Input 1 Input 1 Input 2 Input 2 J2 -Vin +Vin -Vin +Vin GND (-) GND (-) Vout (+) Vout (+) J3 Voltage Control 1 For Input 1 S+ S- J4 Voltage Control 2 For Input 2 S+ S- J5 DC-OK Signal DC-OK Relay Contact Remote ON/OFF Remote ON/OFF 31