Trip amplifier for monitoring
AC/DC circuits
Contents
Trip amplifier for monitoring AC/DC circuits
Trip amplifier for monitoring AC/DC circuits
Trip amplifier for monitoring AC/DC circuits – Overview
E.2
WAVESERIES – Limit value monitoring
E.4
PLUGCONTROL – Current monitoring
E.6
WAVESERIES – Voltage monitoring
E.8
E
2028820000
E.1
Trip amplifier for monitoring
AC/DC circuits
Trip amplifier for monitoring AC/DC circuits – Overview
Trip amplifier for monitoring AC/DC circuits
Monitoring AC/DC currents and voltages within
single-phase and three-phase power networks.
Some WAVESERIES products provide the function of
monitoring voltage and current. Typical uses include
low voltage distribution applications. This includes the
monitoring of phase voltages and current while controlling
actuators. Another application is in monitoring dropouts of a
power supply, or accumulators and feed-in systems within
industrial production lines. There are many applications for
threshold monitoring (trip amplifier) products in process
automation. Typically they are used to generate alarms
when „out-of-limits“ signals are detected with fill levels, flow
quantities or temperature signals.
E
The PLUGCONTROL series of current monitoring products
monitor DC current up to 10 amps. They can be used in
applications to monitor the functioning of valves, servocontrols and DC motors. The pluggable detector uses the
same socket (base) as Weidmüller PLUGSERIES relays and
optos socket base so it uses the same quick-and-easy to use
pluggable ZQV cross-connections for saving wiring time. A
lever is provided to quickly release or instal the detector.
E.2
Features
WAVECONTROL:
• Threshold monitoring of analogue standard signals
• Measuring AC currents ranging from 1 to 30 A
•Monitoring DC and AC voltages up to 400 V
• Fully adjustable switching thresholds
• Relay outputs for monitoring threshold
• Versatile pluggable connection method – screw or spring
PLUGCONTROL:
• Monitoring for DC currents ranging from 0.5 to 10 A
• Very small, pluggable monitoring unit
•Reed relay contact for monitoring and measuring current
• Install on standard base
• Quick initial commissioning – with replaceable electronics
•Minimal wiring effort – with pluggable ZQV 2,5N crossconnector
2028820000
Trip amplifier for monitoring
AC/DC circuits
Trip amplifier for monitoring AC/DC circuits – Overview
E
Threshold monitoring of analogue
standard signals
Current monitoring
Voltage monitoring
2028820000
E.3
Trip amplifier for monitoring
AC/DC circuits
WAVESERIES - Limit value monitoring
Relay output
DC/Alarm
• 3-way isolation
• Low trip / high trip
• FAILSAFE / NON-FAILSAFE
• 2 relay outputs 250 V AC / 3 A
6ZLWFKSRVLWLRQVHWWLQJRSWLRQV
IXQFWLRQ
&KDQQHO$+LJK7ULS
&KDQQHO$/RZ7ULS
&KDQQHO%+LJK7ULS
&KDQQHO%/RZ7ULS
)$,/6$)(&KDQQHO
121)$,/6$)(&KDQ
U/I
VC
૛
૛
Technical data
Input
Input voltage
Input current
Input resistance, voltage/current
Output
Contact assembly
Contact material
Switching thresholds
Hysteresis
Max. switching voltage, AC
Continuous current
Function
Temperature coefficient
Status indicator
General data
Configuration
Supply voltage
Power consumption
Current-carrying capacity of cross-connect.
Ambient temperature
Default setting
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Pollution degree
Overvoltage category
Clearance & creepage distances
Insulation voltage
2 CO contacts
AgNi 90/10
1...90 % (independently for channel 1 and channel 2)
1...10 % (independent for channel 1 and channel 2)
250 V
3A
Open-circuit/closed-circuit principle
≤ 500 ppm/K
LED green ON: OK, LED red ON: alarm (per channel)
૛
6:
૛
૛
૛
૛
૛
૛
RQ
RII
121)$,/6$)(
)$,/6$)(
/RZ7ULS
+LJK7ULS
6LJQDOWKUHVKROG
+\VWHUHVH
0...10 V
0...20 mA
≥ 100 kΩ / ≤ 110 Ω
૛
7KHUHOD\SLFNVXSZKHQWKHDODUPLVWULJJHUHG
7KHUHOD\GURSVRXWZKHQWKHDODUPLVWULJJHUHG
$QDODUPLVDOVRWULJJHUHGLQWKH)$,/6$)(PRGH
LIIRUH[DPSOHWKHRSHUDWLQJYROWDJHWRWKH
PRGXOHVIDLOV
$ODUPLVWULJJHUHGLIWKHVLJQDOLVXQGHU
WKHWKUHVKROG
$ODUPLVWULJJHUHGLIWKHVLJQDOLVRYHU
WKHWKUHVKROG
$GMXVWPHQWVRIWKHVLJQDOWKUHVKROG
DUHPDGHIRUFKDQQHOZLWKWKHSRWHQWLRPHWHU
3DQGVHSDUDWHO\IRUFKDQQHOYLD
SRWHQWLRPHWHU3
$GMXVWPHQWVRIWKHK\VWHUHVLVDUHPDGH
IRUFKDQQHOZLWKWKHSRWHQWLRPHWHU3DQG
VHSDUDWHO\IRUFKDQQHOYLDSRWHQWLRPHWHU3
:$9($1$/2*'&$ODUP
²$ODUPLQGLFDWLRQ
([DPSOH
DIP switch, Potentiometer
24 V DC ± 25 %
Typically 1 W both relays picked up
≤2A
0 °C...55 °C
Channel A/B: low trip and FAILSAFE
CE; cULus; EAC
6LJQDOWKUHVKROGKLJKWULS
+\VWHUHVLV
DIN EN 50178
EN 61000-4-2, -3, -4, -5, -6
300 V
4 kV
2
III
≥ 3 mm
2 kVeff / 5 s
6LJQDOWKUHVKROGKLJKWULS
+\VWHUHVLV
,QSXWUDQJH
E
5HOD\121)$,/6$)(
5HOD\121)$,/6$)(
([DPSOH
mm²
mm
Screw connection
2.5/0.5/2.5
92.4/17.5
Tension clamp connection
1.5/0.5/2.5
92.4/17.5
+\VWHUHVLV
Ordering data
Screw connection
Tension-clamp connection
Type
WAS5 DC/Alarm
WAZ5 DC/Alarm
Qty.
1
1
Order No.
8543820000
8543880000
Note
Accessories
Note
E.4
6LJQDOWKUHVKROGKLJKWULS
+\VWHUHVLV
6LJQDOWKUHVKROGORZWULS
,QSXWUDQJH
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
5HOD\)$,/6$)(
5HOD\)$,/6$)(
7LPH
Cross-connector for power supplies and markers – refer to Accessories
2028820000
E
2028820000
E.5
Trip amplifier for monitoring
AC/DC circuits
Trip amplifier for monitoring
AC/DC circuits
PLUGCONTROL - Current monitoring
Relay output
PAS CMR 0.5...2.5 A DC
PAS CMR 2.0...5.0 A DC
• Monitors currents up to 10 A DC
• Used with valves, servo-controls or DC motors
• Pull-up / pull-down resistor 4.7 kΩ
14/24
14/24
4.7kΩ
4.7kΩ
11/21
A1
0.5...2.5A DC
A1
100V
0.1A
2.0...5.0A DC
12/22
A2
A2
11/21
100V
0.1A
12/22
Technical data
Input
Input current
Max. current
Making current threshold
Input resistance, current
Secure off
Pulse duration
Output
Switching current
Switching voltage AC / Switching voltage DC
Max. switching frequency
Contact assembly
Contact material
General data
Configuration
Ambient temperature
Humidity
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
E
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
0.5...2.5 A DC
7.5 A for 10 s
≤ 500 mA
< 50 mΩ
≤ 50 mA
min. 1 ms
2...5.0 A DC
15 A for 10 s
≤2A
< 50 mΩ
≤ 300 mA
min. 1 ms
100 mA
/ 1 V...100 V1 V...100 V
15 Hz
1 NO contact
RH/Rd (Reed contact)*
100 mA
/ 1 V...100 V1 V...100 V
15 Hz
1 NO contact
RH/Rd (Reed contact)*
none
0 °C...55 °C
5–95% rel. humidity, Tu = 40°C, no condensation
CE; cULus; EAC
none
0 °C...55 °C
5–95% rel. humidity, Tu = 40°C, no condensation
CE; cULus; EAC
DIN EN 50178 (secure separation)
EN 55011, EN 61000-6-1, 2, 3, 4
300 V
6 kV
4 kVeff / 1 min.
III
2
≥ 5 mm (grout encapsulated)
DIN EN 50178 (secure separation)
EN 55011, EN 61000-6-1, 2, 3, 4
300 V
6 kV
4 kVeff / 1 min.
III
2
≥ 5 mm (grout encapsulated)
Screw connection
1.5 / 2.5 / 2.5
92 / 15.3 /
Screw connection
1.5 / 2.5 / 2.5
92 / 15.3 /
* The peak current should be limited to 100 mA when under capacitive loads.
* The peak current should be limited to 100 mA when under capacitive loads.
Type
PAS CMR 0,5...2,5 A DC
Type
PAS CMR 2,0...5,0 A DC
Ordering data
Screw connection
Qty.
10
Order No.
8742610000
Qty.
10
Order No.
8742620000
Note
Accessories
Note
E.6
Cross-connectors and markers - refer to WAVESERIES accessories
Cross-connectors and markers - refer to WAVESERIES accessories
2028820000
Relay output
Trip amplifier for monitoring
AC/DC circuits
PLUGCONTROL - Current monitoring
PAS CMR 4.5...10 A DC
• Monitors currents up to 10 A DC
• Used with valves, servo-controls or DC motors
• Pull-up / pull-down resistor 4.7 kΩ
14/24
4.7kΩ
A1
4.5...10A DC
A2
11/21
100V
0.1A
12/22
Technical data
Input
Input current
Max. current
Making current threshold
Input resistance, current
Secure off
Pulse duration
Output
Switching current
Switching voltage AC / Switching voltage DC
Max. switching frequency
Contact assembly
Contact material
General data
Configuration
Ambient temperature
Humidity
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
E
4.5...10 A DC
30 A for 10 s
≤ 4.5 A
< 50 mΩ
≤ 600 mA
min. 1 ms
100 mA
/ 1 V...100 V1 V...100 V
15 Hz
1 NO contact
RH/Rd (Reed contact)*
none
0 °C...55 °C
5–95% rel. humidity, Tu = 40°C, no condensation
CE; cULus; EAC
DIN EN 50178 (secure separation)
EN 55011, EN 61000-6-1, 2, 3, 4
300 V
6 kV
4 kVeff / 1 min.
III
2
≥ 5 mm (grout encapsulated)
Screw connection
1.5 / 2.5 / 2.5
92 / 15.3 / 95
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
* The peak current should be limited to 100 mA when under capacitive loads.
Ordering data
Screw connection
Type
PAS CMR 4,5...10 A DC
Qty.
10
Order No.
8742630000
Note
Accessories
Note
2028820000
Cross-connectors and markers - refer to WAVESERIES accessories
E.7
Trip amplifier for monitoring
AC/DC circuits
WAVESERIES - Voltage monitoring
Relay output
VMR V AC / DC
• 3-way isolation
• Monitoring of single-phase systems up to 260 V AC/DC
• 4 input ranges per DIP switch can be selected
• 1 relay module with CO contact
• Switchable hysteresis
• Switch adjusted via potentiometer
• Reset input
Single-phase
Table of setting options
6HWSRLQW
9$&'&«9$&'&
SK
Technical data
Input
Input voltage
Input frequency
Max. voltage
Output
Max. switching voltage, AC
Switching current
Continuous current
Hysteresis
24...70 / 70...140 / 140...210 / 210...260 V AC / DC
50...60 Hz
260 V AC / DC
250 V
8A
3A
24...70 V AC, small = 5 V / large = 10 V, 70–260 VAC, small = 8 V ⁄
large = 16
≤ 250 ppm/K
< 300 ms
< 0.3 % of set range
LED green = OK / LED yellow/red = alarm status
Temperature coefficient
Step response time
Repeat accuracy
Status indicator
General data
Supply voltage
Reset input voltage, min./max.
Pulse duration
Configuration
from the measuring circuit
18 V DC / 30 V DC
≥ 700 ms
DIP switch, Potentiometer, Alarm status reset via reset input or button
Impulse withstand voltage
Input/output, input/reset input, reset input/output: 4 kV
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
2 kVeff
III
2
≥ 3 mm
Screw connection
2.5 / 0.5 / 2.5
96.5 / 17.5 /
DIN EN 50178
EN 55011, EN 61000-6, EN 61326
input/output, input/reset input, reset input/output: 300 V
n
n
n
(Set permanently to closed-circuit principle)
Operating point
Hysteresis
50 %
1
0
Relay/High Trip/Memory out
1
Relay/High Trip/Memory on
0
1
Reset for output
0
100 %
Input range
Note
n
Time
Qty.
1
Order No.
8705640000
min. 700 ms
(Set permanently to closed-circuit principle.)
Operating point
Hysteresis
50 %
Time
Reset
Screw connection
Abb.2: Undervoltage monitoring
Alarm set to “low trip”
(Set permanently to closed-circuit principle.)
Ordering data
Type
WAS5 VMR 1ph
n n n n n
n n
Abb.1: Overvoltage monitoring
Alarm set to “high trip“
(Set permanently to closed-circuit principle.)
Input range
DIP switches: ON = 1,2,5,8 / OFF = 3,4,6,7
-10 °C...55 °C
-20 °C...70 °C
CE; cULus; EAC
n n
Status indicator
Set value not exceeded.
Alarm status.
Alarm status can be reset because
set value has been exceeded.
100 %
Default setting
Ambient temperature
Storage temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
1 2 3 4 5 6 7 8
= on
n = out
Output
E
Output
Input
24 V AC/DC...70 V AC/DC
70 V AC/DC...140 V AC/DC
140 V AC/DC...210 V AC/DC
210 V AC/DC...260 V AC/DC
Trip
High Trip
Low Trip
Memory
Memory on
Memory out
Hysteresis
Hysteresis small
Hysteresis large
Input voltage
AC voltage
DC voltage
Reset
,QSXW
VC
QF
²
9'&«9'&
905
: $6
5HVHW
Uac
1
0
Relay/High Trip/Memory out
1
0
Relay/High Trip/Memory on
1
0
Reset for output
min. 700 ms
Accessories
Note
E.8
Markers – refer to Accessories.
2028820000
Relay output
VMR V AC
• 2-way isolation
• Monitoring of 1- and 3-phase systems from
80 to 400 V AC/DC
• Adjustable by DIP switches
• Monitoring of low and surge voltages
• Detects loss of phase
• 2 relay modules with CO contact
Three-phase
Trip amplifier for monitoring
AC/DC circuits
WAVESERIES - Voltage monitoring
Table of setting options
Uac
11
80…250 V AC/DC L1
14
80…250V AC/DC L2
4
N
5
80…250V AC/DC L3
6
12
21
L1
L2
L3
24
22
7
8
9
10
11
12
Technical data
Input
Input voltage
Input current
Output
Contact assembly
Max. switching voltage, AC
Continuous current
Hysteresis
Temperature coefficient
Step response time
Repeat accuracy
Status indicator
General data
Configuration
200…400 V AC/DC 1~, 80…250 V AC/DC 3~
< 10 mA DC; 15 mA AC
DIP switch, Potentiometer, Alarm status reset via reset input or button
from the measuring circuit
DIP switches: ON = 1,2,4 / OFF = 3
0 °C...50 °C
CE; cULus; EAC
2
◼
3
4
n
◼
◼
n
◼
◼
n
◼
◼
◼n
E
Fig.1: Overvoltage and undervoltage monitoring,
example of setting
– 3-phase monitoring
– Setting limit value to upper operating point:
230 V Hysteresis 5% = -12.5 V
– Lower operating point 10% less 230 V - 25 V = 205 V
Hysteresis 5% = + 12.5 V
– The device operates with the operating current principle.
– All 3 phases monitored in parallel
U
Upper operating point
DIN EN 50178
EN 55011, EN 61000-6, EN 61326
600 V
6 kV
4 kVeff / 1 min.
III
2
Output circuit: 1.8 mm; input circuit, output circuit 1/output circuit 2: 3
mm; input/output: 5.5 mm
Screw connection
2.5 / 0.5 / 2.5
96.5 / 22.5 /
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
1
Status indicator
Voltage is in set range
2 CO contacts
250 V
3A
5% of final value
≤ 300 ppm/K
< 300 ms
< 0.3 % of set range
Green LED
Supply voltage
Default setting
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
Input
3 phases 80 V AC/DC...250 V AC/DC
1 phase 200 V AC/DC...400 V AC/DC
Limit value
Setting to upper switching point
Setting to lower switching point
Hysteresis
Hysteresis, small
Hysteresis, large
Fault tolerance
Operating current method
Closed-circuit current method
◼ = on
◼
n = off
Hysteresis
Input range
3
200…400 V AC/DC
Hysteresis
10%
Lower operating point
0
1
Output
1
0
1
Time
Relay 1/Operating current
principle, Overvoltage
Relay 2/Operating current
principle, Undervoltage
0
Fig. 2: Overvoltage and undervoltage monitoring,
example of setting
– 3-phase monitoring
– Setting limit value to lower operating point:
150 V Hysteresis 5% = +12.5 V
– Upper operating point 20% greater 150 V + 50 V = 200 V
Hysteresis 5 % = –12. 5 V
– The device operates with the closed-circuit current principle.
– All 3 phases monitored in parallel
U
Upper operating point
Ordering data
Qty.
1
Order No.
8705630000
Note
20%
Hysteresis
Lower operating point
0
1
Output
Screw connection
Type
WAS2 VMR 3ph
Input range
Hysteresis
0
1
0
Time
Relay 1 /Closed-circuit
current principle,
Overvoltage
Relay 2 /Closed-circuit
current principle,
Undervoltage
Accessories
Note
2028820000
Markers – refer to Accessories.
E.9
E
E.10
2028820000
Trip amplifier for monitoring
AC/DC circuits