Download

Contents
Signal converters
2028820000
Signal converters
Signal converters
Universal signal converters – Overview
D.2
ACT20C – Overview
D.4
ACT20C – Network-compatible signal converter
D.7
ACT20C – Station
D.8
ACT20P – Overview
D.16
ACT20P – Universal measurement converter
D.20
ACT20P – Signal splitter
D.26
ACT20P – Signal converter
D.27
ACT20P – Limit value monitoring
D.29
ACT20P – Current measuring transducer
D.32
ACT20P – Bridge measuring transducer
D.34
WAVESERIES – Overview
D.38
WAVESERIES – Universal signal converters and trip amplifiers, configurable
D.40
WAVESERIES – DC/DC 3-way isolator
D.44
WAVESERIES – DC/DC 2-way isolator
D.54
WAVESERIES – DC/DC passive isolator
D.56
WAVESERIES – Temperature measuring transducer
D.60
WAVESERIES – Frequency signal isolator/converter configurable
D.70
WAVESERIES – Current measuring transducer
D.72
WAVESERIES – Voltage measuring transducer
D.74
Isolating converter for serial interfaces
D.76
D
D.1
Universal signal converters – Overview
Signal converters
Signal converters
Weidmüller analogue conditioners and monitoring
modules are offered in touch-safe IP 20 housings and
with space-saving DIN mounting.
This product line includes: passive and active isolation
amplifiers for analogue current and voltage signals;
measurement isolators for measuring temperatures,
resistances, frequencies, AC/DC currents and voltages; and
universally-configurable signal isolating converters with
integrated threshold monitoring.
D
Weidmüller wide product range covers all the functions
for isolating, converting and monitoring analogue signals.
These products can therefore be used in practically all
industrial measurement applications to safeguard the basic
functionality between field signals and post-processing
systems. A comprehensive line of accessories is also available
for the analogue signal converter product line. These include
pluggable cross-connectors, markers, and configuration
adapters for the software-programmable products.
D.2
Features
• Can handle a variety of measurements
• Standard analogue signals on the output side
• Configurable options
•Stand-alone, pluggable connection mechanism – screw or
tension clamp
• Tool-free installation
•Minimal commissioning needed - often with no
calibration.
•Minimal wiring effort – with pluggable ZQV 2.5N
cross-connector
• Excellent functionality
• Clear type designations makes selection easy
• High level galvanic isolation
• International approvals
2028820000
Signal converters
Universal signal converters – Overview
D
ACT20C
ACT20P
WAVESERIES
2028820000
D.3
ACT20C – Overview
Signal converters
Your process requires the utmost attention
Our new ACT20C signal conditioners support you in achieving this
Many process parameters in your system are handled by
your control system, which shows you the current status of
your process. Even so, do you have a full overview of critical
system states? And this at all times, at every location, and
with the recent system history?
With the ACT20C, you receive accurate information on the
status of the sensors, signal processing and cabling. Data
can be called up and will depending on your individual
communications infrastructure. This comprehensive
overview allows you to accurately analyse errors and faults,
and initiate targeted actions taken by system operators
and maintenance personnel. By doing so, this technology
contributes to ensuring reliable system operation.
D
D.4
2028820000
ACT20C – Overview
Signal converters
ACT20C signal conditioner with Ethernet interface
Comprehensive process transparency is provided
by the transfer of diagnostics information, signals and data
You would like more process transparency for your
systems. We support you with signal conditioners
that supply you with precise information via our
Ethernet interace. Let’s connect.
To be able to control systems and processes optimally, you
require a constant flow of information on the current states
of individual applications, devices and functions.
Our ACT20C signal conditioner not only monitors the signal
conversion, but also communicates precise information
on device status, signals and data directly to connected
computer and control systems.
D
Our Ethernet interface enables an event-controlled transfer
of diagnostics information, which in turn supports the
elimination of faults in, for example, plant operation.
Universal signal conversion
Can be used in a multitude of
applications thanks to customer
and application specific defined
conversion methods with just one
single module.
Simple operation and configuration
Software supported configuration allows a fast
application of settings and simple operation.
Simple remote access
Continuous monitoring of device and system
functions, simple and affordable integration of
existing Ethernet networks.
ETH
I, U
I, U
PS
2028820000
D.5
ACT20C – Overview
Signal converters
Detailed analysis and presentation of core process parameters
The ACT20C supplies key parameters and historical data,
independent of the location
D
D.6
Thanks to the ACT20C, Weidmüller is now the first to offer
a solution which supplies you with extensive diagnostic
and status information without the need to deal with the
complexity of field bus systems.
the front panel or via the Ethernet, and performance is
ensured through the manufacturer-independent FDT/DTM
software platform. To work with this platform, Weidmüller
provides the WI-Manager universal FDT frame application.
The isolating converters are based on the proven, robust
technology of transferring analogue signals to the DCS
system. Various signal sources and field devices can be
connected to the input side of the isolating converters.
As a result of this, the ACT20C can be configured for the
user-defined processing of current, voltage and transmitter
signals. Access is accomplished via a service interface on
Data collected in the ACT20C is made available over
the Ethernet via Modbus TCP. Depending on the
communications infrastructure, you can make this data
available to your SCADA system within your network, and
you can also access it via the Internet from any location
using an industrial Ethernet router.
2028820000
ACT20C – Network-compatible signal converter
Network-ready signal converter for
DC voltage and current signals
ACT20C-AI-AO-MTCP-S
Signal converters
Network-compatible signal converter with Ethernet
• Scalable current or voltage input
• Current or voltage output
• Limit-value monitoring with parameterisation options
• Diagnostics on device status, signals and line faults
via Modbus
• PC configuration with FDT/DTM software, download
link at www.weidmueller.com
U
I
–
V
I
–
+
mA
12
+
–
Tx +
13
14
U
RJ45
11
ETH
I, U
I, U
PS
63
–
64
+
51
–
52
+
I
–
+
53
54
24 V DC
D
Technical data
Input
Input current
Input voltage
Sensor supply
Output
Output current
Output voltage
load impedance current
load impedance voltage
Signal processing
Transfer functions
Limit-value monitoring
Condition Monitoring
Diagnostics
0...20 mA, 4...20 mA
0…10 V
> 17 V DC at 20 mA
0...20 mA, 4...20 mA
0...10 V
≤ 500 Ω
≥ 10 kΩ
Linear, Inverse
Process alarms with adjustable delay and hysteresis
Process value: sensor value, output value
Device status, Short-circuit (input/output), Cable break (input/output),
Overload (sensor/output)
General data
Supply voltage
Power consumption
Accuracy
Temperature coefficient
Ambient temperature (operational)
Storage temperature
Humidity
Protection degree
Insulation coordination
Galvanic isolation
Rated voltage ⁄ test voltage: input/output to output/input ⁄ supply⁄
Ethernet interface
Rated voltage ⁄ test voltage: Ethernet interface to supply ⁄ functional
earth to supply ⁄ Ethernet interface
Rated voltage ⁄ test voltage: functional earth to input ⁄ output
24 V DC ± 25 %
≤ 3.5 W
< 0.15% end value (+ 0.05% > 55°C), Current: 1 uA / 30 uA (+ 10 uA
> 55°C), Voltage: 1 mV / 15 mV (+ 5 mV > 55°C)
≤ 0.01 % / °C
-20 °C...70 °C
-20 °C...85 °C
0...95 % (no condensation)
IP 20
4-way isolator;, between input / output / power supply / Ethernet
300 Vrms / 1.7 kV rms on secondary electric circuits, reinforced
insulation
31.2 VDC / 0.9 kV rms on secondary electric circuits, basic insulation
300 Vrms / 1.1 kV
rms
on secondary electric circuits, basic insulation
2
Pollution degree
Communication
RJ45 ports
Interface
Addressing
Protocol
Configuration
Approvals
Standards
Recommendations
10/100BaseT(X), auto negotiation
RJ45: female-female, Cat.5 to 100 MHz, Jack plug for CBX200
DHCP or manual adjustment
FDT/DTM, Modbus/TCP
FDT/DTM (Ethernet or service interface)
DIN EN 61010-1, EN 61326-1:2006
Namur NE43, Namur NE44, Namur NE107
Ordering data
Type
ACT20C-AI-AO-MTCP
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height/Weight
Note
2028820000
mm²
mm
Qty.
1
Order No.
1334490000
Screw connection/ RJ45 plug-in connector
2.5 mm²/0.5 mm²/2.5 mm²
113.6/22.5/180 g
D.7
ACT20C – Station
Signal converters
Take a preventative approach to monitoring plants and processes
ACT20C gateway conveys precise status information on your devices
Diagnostic and status information that’s as comprehensive
as possible and comes from all areas of an automation
solution goes a long way in helping to optimise process
control.
D
With the ACT20C gateway and the communication-capable
signal converters, for the first time ever we can obtain
process data from the signal conversion level – regardless
of the automation solution selected. An Ethernet interface
enables simple access to the desired information. The data
obtained in the ACT20C gateway is provided via Modbus
TCP or OPC, or can be displayed directly in an FDT frame
application.
The flexibility of the ACT20C gateway makes it easy
for you to optimise your processes. Depending on the
communication infrastructure, you can make this data
available throughout your entire network or pass it on to
your SCADA or maintenance system. The data can even be
used from any location over the Internet via an Industrial
Ethernet router.
The Ethernet interface enables events-driven transmission of
diagnostic information. So, for example, measurement data
about the pumps, which is continuously collected throughout
their service life, provides information about their performance
and operational status.
Your
special
advantages:
D.8
More transparency in your process automation
For the first time ever, extensive diagnostic and status information
(which you can call up via the Ethernet interface) is available to you at status
conversion level.
2028820000
ACT20C – Station
Signal converters
Simple commissioning, fast maintenance
The station concept with “Plug & Produce”
and “Hot Swapping” makes installation and
maintenance work faster and thus more
efficient.
All the process parameters at a glance
The status of devices, environmental conditions
and functions is continually monitored over the
Ethernet.
D
Extensive diagnostics concept
Support of fast and exact cause analysis
according to NE107, NE43 and NE44.
2028820000
Clever software configuration
The software configuration based on the FDT
and FDT2 standards makes parameterisation,
documentation and data backup easier.
D.9
ACT20C – Station
Condition monitoring
Preventative maintenance strategies using
automation-independent information about
operating conditions and process data for
connected devices.
Signal converters
Multiple limit value monitoring
The main alarm and auxiliary alarm permit
precise identification of all alarm situations.
D
Smart software configuration
The software configuration based on the FDT
and FDT2 standards makes parameterisation,
documentation and data backup easier.
High process reliability
A galvanic four-way isolation and an impulse
withstand voltage of 6.4 kV pursuant to
IEC 61010-2-201 guarantee optimum fusing.
D.10
2028820000
ACT20C – Station
ACT20C-GTW-100-MTCP-S
• Access to all data from the devices connected to an
ACT20C station
• RJ45 port with Ethernet TCP/IP
• Configuration by means of the FDT/DTM standard
• Station management with “Plug & Produce” and “Hot
Swapping”
Communication signal
Ethernet / Modbus TCP
Ethernet
Signal converters
Gateway for ACT20C station
Power supply
Supply
64
63
U
I
–
V
I
–
+
mA
12
+
–
Tx +
13
14
U
RJ45
11
I, U
I, U
PS
64
+
51
–
52
+
Communication L
–
+
Communication H
61
Supply GND
Supply +24 V DC
54
D
Technical data
General data
Configuration
Power consumption, max.
Supply voltage
Insulation coordination
Rated voltage ⁄ test voltage: Ethernet interface to supply ⁄ functional
earth to supply ⁄ Ethernet interface
Standards
62
53
24 V DC
Communication
Addressing
Configuration
RJ45 ports
Interface
DIN Rail Bus CH20M
GND
85 84 83 82 81
ETH
63
–
I
+18...31.2 V DC
DHCP or manual adjustment
With FDT/DTM software, DHCP
10/100BaseT(X), auto negotiation
Ethernet 10/100 Base T, Jack plug for CBX200, Communication via
CH20M rail bus with all current measuring transducers (ACT20CCMT-x)
With FDT/DTM software, DHCP
2.2 W
16,8 V…31,2 V
30 V AC RMS
IEC 61010-1, IEC 61010-2-201:2013, 1st Edition, IEC 61326-1:2012
Test voltage
Impulse withstand voltage
Pollution degree
Overvoltage category
1.1 kV
0,5 kV (1.2/50 μs)
2
II
Dimensions
Clamping range (nominal / min. / max.)
Depth / Height / Width
Note
2.5 / 0.5 / 2.5
113.6 / 117.2 / 22.5 mm
Ordering data
Type
ACT20C-GTW-100-MTCP-S
Qty.
1
Order No.
1510370000
Note
Accessories
Note
2028820000
D.11
ACT20C – Station
Signal converters
Communicative current-measuring transducer
ACT20C-CMT
• Measurement and monitoring of AC/DC current
• Input and output ranges are adjustable
• Contact-free through-hole technology
• Relay output for limit value alarm with switching
threshold, delay, hysteresis
• Monitoring/configuration via ACT20C station/gateway
Input signal
Output signals
Current
Current, voltage
44
Output
Output
43
+
I for AC
42
mA
+
Input
V
I for DC
-
-
41
Output signal
Relay
24
Output
Output
23
U
I
–
V
I
–
+
mA
12
+
–
Tx +
D
13
14
U
RJ45
11
ETH
I, U
I, U
PS
63
–
64
+
51
–
52
+
I
22
Input
CO
21
–
+
DIN Rail Bus CH20M
53
85 84 83 82 81
Communication L
Communication H
54
Supply GND
Supply +24 V DC
24 V DC
Technical data
Input
Input measurement range
Input signal
Input frequency
Output (analogue)
Output voltage [output analogue]
Output current [output analogue]
Load resistance current [output analogue]
Load resistance voltage [output analogue]
Output (digital)
Type
configurable, 0…5/10 A AC (RMS) or DC, 0…40/50/60 A AC (RMS)
or DC
Current-carrying cable in feed-through hole, Diameter 10.5 mm
AC: 15…700 Hz
adjustable, 0...10 V, 2…10 V, 0...5 V, 1...5 V, -5…+5 V, -10...+10 V
adjustable, 0...20 mA, 4...20 mA, -20…+20 mA
≤ 600 Ω
≥ 10 kΩ
&XUUHQW
VLJQDO
t
+LJKDODUP
t
+LJKDODUPVHWSRLQW
+\VWHUHVLV
W!WDG
2XWSXW
WWDG
WDG$ODUPGHOD\
7LPH
WDG$ODUPGHOD\
/RZDODUP
&XUUHQW
VLJQDO
Relay, 1 CO contact, Process alarms (4x) with hysteresis, with alarm
delay (configurable) 0…180 s
W!WDG
WWDG
+\VWHUHVLV
/RZDODUPVHWSRLQW
Rated switching current
Max. switching voltage, AC
General data
Configuration
Step response time
Temperature coefficient
Supply voltage
Insulation coordination
Rated voltage
EMC standards
Galvanic isolation
Test voltage
Impulse withstand voltage
Pollution degree
Overvoltage category
Dimensions
Clamping range (nominal / min. / max.)
Depth / Height / Width
Note
6A
250 V
W
2XWSXW
With FDT/DTM software, via gateway (ACT20C-GTW-100-MTCP-S),
Addressing via DIP switches
< 300 ms
≤ 200 ppm/K
16,8 V…31,2 V, via the system bus
WDG$ODUPGHOD\
7LPH
WDG$ODUPGHOD\
5HOD\GHHQHUJL]HG/('\HOORZ´2))µ 5HOD\HQHUJL]HG/('\HOORZ´21µ
300 V ACrms
IEC 61326-1
8VHUDGGUHVV
4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
4 kV
6.4 kV (1.2/50 µs)
2
III
2.5 / 0.5 / 2.5
113.6 / 117.2 / 22.5 mm
W
█
',3VZLWFK6
█
█
█
█
█
█
█
█
█
█
█
█
█
█
█
█
21
Ordering data
Input measurement range 0...5/10 A
Input measurement range 0...40/50/60 A
Type
ACT20C-CMT-10-AO-RC-S
ACT20C-CMT-60-AO-RC-S
Qty.
1
1
Order No.
1510240000
1510420000
Note
Accessories
Note
D.12
2028820000
ACT20C – Station
Bus termination terminal
ACT20C-LBT-10
Signal converters
• Electrical termination of the CH20M rail bus of an
ACT20C station
• Acts as a mechanical end bracket at the same time
U
I
–
V
I
–
+
mA
12
+
–
Tx +
13
14
U
RJ45
11
ETH
I, U
I, U
PS
63
–
64
+
51
–
52
+
I
–
+
53
54
24 V DC
D
Technical data
Humidity
Ambient temperature
General data
Tightening torque, min.
Tightening torque, max.
Mounting rail
Dimensions
Depth / Width / Height
5...95 %, no condensation
-25 °C...+60 °C
1.2 Nm
2.4 Nm
TS 35
63 / 20.6 / 56
Note
Ordering data
Type
ACT20C-LBT-10
Qty.
1
Order No.
1510340000
Note
Accessories
Note
2028820000
D.13
Signal converters
CH20M rail bus
CH20M rail bus
Quick and safe power supply through the DIN rail.
D
This customer-friendly infrastructure solution brings power,
signals and data to the rail in a quick and reliable manner.
The rail bus can replace the tedious individual wiring process
with a flexible and uninterrupted system solution. As a result,
the customer saves time and cost-especially if any module
changes are needed later, as other adjacent modules are
not disturbed. The uninterrupted system bus is securely
integrated within the 35 mm standard mounting rail.
Whether 7.5 mm or 15 mm high, the custom-fit rail profiles
are easy to install on all TS 35 standard rails in accordance
with DIN EN 60715.
The supply of 24 V DC to the power rail can be from any
one of the auxiliary powered ACT20M modules, when that
module is itself externally supplied. This allows the rail to
power up to 8 other modules (approximately 400 mA). For
powering additional ACT20Ms, a separate Feed-In module
can be used.
The ACT20-Feed-In-Basic provides a simple and compact
(6 mm width) power supply interface to the rail, for
supplying up to 2.5 A (up to 50 x ACT20M modules).
The resistant gold-plated contacts ensure a permanent and
reliable contact. The ACT20M modules are simply snapped
onto the mounting rail and are automatically in contact with
the DIN rail bus.
The ACT20-Feed-In-Pro is a more powerful 22.5 mm wide
solution. This takes 2 external 24 V DC inputs, and via
internal diodes provides a redundant supply to the rail, and
an alarm output in the case of input failure.
D.14
2028820000
CH20M rail bus
Signal converters
Rail bus accessories
CH20M BUS-PROFIL TS35x7.5/1000
CH20M BUS-PROFIL TS35x15/1000
CH20M BUS 4.50/05 AU/1000
Support section for bus circuit board
Support section for bus circuit board
Bus PCB
• Support section for TS 35 x 7.5
• Length: 250, 500 or 750 mm
• Support section for TS 35 x 15
• Length: 250, 500 or 750 mm
• Bus circuit board for use on TS 35 x 7.5
and TS 35 x 15
• Length: 250, 500 or 750 mm
• Five conductor paths, gold-plated
• Electrical rating: 63 V AC, 5 A/conductor path
Ordering data
Type
CH20M BUS-PROFIL TS35x7.5/250
CH20M BUS-PROFIL TS35x7.5/500
CH20M BUS-PROFIL TS35x7.5/750
Qty.
10
10
5
Order No.
1248150000
1248160000
1248170000
Ordering data
Type
CH20M BUS-PROFIL TS35x15/250
CH20M BUS-PROFIL TS35x15/500
CH20M BUS-PROFIL TS35x15/750
Qty.
5
5
5
Order No.
1248180000
1248190000
1248210000
Ordering data
Type
CH20M BUS 4.50/05 AU/250
CH20M BUS 4.50/05 AU/500
CH20M BUS 4.50/05 AU/750
Qty.
10
10
5
CH20M BUS-ADP TS35/1000
CH20M BUS-AP LI TS35x7.5 & 15
CH20M BUS-AP RE TS35x7.5 & 15
Cover plate
End plate
End plate
• Cover plate for DIN rail bus
• Length: 250, 500 or 750 mm
• End plate for DIN rail bus
• Fits on TS 35 x 7.5 and TS 35 x 15
• left
• End plate for DIN rail bus
• Fits on TS 35 x 7.5 and TS 35 x 15
• right
Ordering data
Type
CH20M BUS-ADP TS35/250
CH20M BUS-ADP TS35/500
CH20M BUS-ADP TS35/750
Qty.
10
10
5
Order No.
1248250000
1248260000
1248270000
Ordering data
Type
CH20M BUS-AP LI TS35x7.5 & 15
Qty.
50
Order No.
1193160000
Ordering data
Type
CH20M BUS-AP RE TS35x7.5 & 15
SET CH20M BUS 250MM TS 35X15
SET CH20M BUS 250MM TS 35X7.5
TS 35x7.5 / TS 35x15
Set
Set
DIN rail
• SET consists of one each of
CH20M BUS 4.50/05 AU/250
CH20M BUS-ADP TS 35/250
CH20M BUS-AP LI TS 35X7.5 & 15
CH20M BUS-AP RE TS 35X7.5 & 15
CH20M BUS-PROFIL TS 35X15/250
• SET consists of one each of
CH20M BUS 4.50/05 AU/250
CH20M BUS-ADP TS 35/250
CH20M BUS-AP LI TS 35X7.5 & 15
CH20M BUS-AP RE TS 35X7.5 & 15
CH20M BUS-PROFIL TS 35X7.5/250
• DIN rail with slot
• Passivated galvanised steel
Ordering data
Type
SET CH20M BUS 250MM TS 35X15
2028820000
Qty.
1
Order No.
1335150000
Ordering data
Type
SET CH20M BUS 250MM TS 35X7.5
Qty.
1
Order No.
1335140000
Ordering data
Type
TS 35X7.5/LL 1M/ST/ZN
TS 35X15/LL 1M/ST/ZN
Order No.
1248220000
1248230000
1248240000
Qty.
50
Order No.
1193170000
Qty.
10
10
Order No.
0514510000
0236510000
D
D.15
Signal converters
ACT20P – Overview
D
Your systems work with analogue current signals
ACT20P signal converters efficiently tackle signal conditioning
and isolation
Your systems and processes are controlled using analogue current
signals. Our signal isolation converters are the reliable and efficient
solution to signal conditioning and galvanic isolation of current signals.
Let’s connect.
Temperature, pressure, weight or distance: your system’s sensors pass on a wide
range of analogue signals. During this process, undesirable transients may occur,
causing faults and damaging your controls’ inputs.
Our ACT20P signal converter delivers reliable protection of controls and remote
I/O inputs against transients and voltage peaks. It also adapts a multitude of
signal variants to standard signals, in addition to being space-saving and efficient.
Its properties make the ACT20P signal converter a low-cost universal solution to
all tasks involving the analogue isolation and conversion of current signals.
Fault-free recording of measured data in
water management
During the final step of water purification,
quality values are checked. To this end, the
signals emitted by the measurement devices
are transferred over several hundred metres
from the switching box on the last setting
basin to the plant control room. There, they are
recorded, analysed and stored. For a smooth
measurement data recording process, our signal
isolation converters filter out all of the faults and
transients according to the latest provisions set
forth in EN 61010.
D.16
2028820000
ACT20P – Overview
Signal converters
Can be integrated in HART® communication
Signal converters are suitable for HART®,
transparent communication.
Reliable connection
Individually customisable protection against
mismatching.
transparent
Rapid device replacement
Practical release lever for simple removal of the
female connector.
D
More space in the cabinet
Two channels measure a mere 12.5 mm wide.
12.5 mm
2028820000
Variants for different applications
The range of products is rounded off
by the intrinsically safe ACT20X signal
converter and the high-performance
ACT20M signal converter, which is just
6 mm across.
D.17
Signal converters
ACT20P – Overview
ACT20P – Selection table
D
Selection table
Input
Miscellaneous
Signal converter
7760054114 ACT20P-CI-CO
12.5
7760054115 ACT20P-CI-2CO
12.5
7760054117 ACT20P-2CI-2CO-12
12.5
Bridge-measuring transducer
1067250000 ACT20P-BRIDGE-S
22.5
Universal measuring converter
1481970000 ACT20P-PRO DCDC II-S
12.5
1 X X
1 X X
2 X
X 2-/3-wire transmitter
X 2-/3-wire transmitter
1 X X
2 X X
2 X X
1
X 4-,6-, wire strain gauges
1 X X X
Reset button (TARE)
1 X X X X
1 X X X
1
± 10 V, ± 20 mA
Output Loop powered, NPN output, Limit
value
0…11V, 0…22mA
1453210000 ACT20P-UI-AO-DO-LP-S
12.5 1 X X X X X X
1477420000 ACT20P-AI-AO-DC-S
Limit value monitoring
12.5 1 X X X X
X ± 100 mA, ± 300 V
± 25 mA, ± 5 A DC, ± 28 V DC,
± 300 V DC, 300 V AC
X 0…11V, 0…22mA
7940045760 ACT20P-UI-2RCO-DC-S
22.5 1 X X X X X X
X
AC/DC Signal measuring transducer
1510470000 ACT20P-CMT-10-AO-RC-S 22.5 1
1510540000 ACT20P-CMT-30-AO-RC-S 22.5 1
1510440000 ACT20P-CMT-60-AO-RC-S 22.5 1
D.18
Output
Miscellaneous
Configuration
Amount
0…20mA
4…20mA
0…10V
Relais
Amount
0…20mA
4…20mA
0…10V
0…5V
TC
RTD
Frequency
Sensor feed
Product
Width (mm)
Order No.
X
1 X X X
± 25 mA, ± 5 A DC, ± 30 V DC, ± 300 V DC,
1
potentiometer, resistance
0…10 A AC/DC
0... 30 A AC/DC
0... 60 A AC/DC
X
X 2 x Limit value relay outputs
1 X X X X ± 10 V, ± 20 mA, Limit value relays
1 X X X X ± 10 V, ± 20 mA, Limit value relays
1 X X X X ± 10 V, ± 20 mA, Limit value relays
Display, DIP switch
Software
DIP switch, Button, LED
Software, Display
DIP switch, potentiometer
DIP switch, potentiometer
DIP switch, potentiometer
2028820000
Signal converters
ACT20P – Overview
Reliable connection
Individually configurable protection
against mismating with release lever
High level of galvanic isolation
U, I,
R, T
D
The galvanic isolation of 2 kV
(300 V rated voltage ) ensures high process reliability
U,I
PS
Simple signal conditioning
Devices configured for converting
standard sensor signals to standard DC
signals.
Universal measurement converter
Signal splitter
Special characteristics
Connection system
Isolation
Rated voltage (V)
Auxiliary power
Signal converter
24 V DC
24 V DC
24 V DC
300 3-way
300 3-way
300 3-way
S
S
S
10...60 V DC
300 3-way
S
24 V - 230 V AC/DC
600 3-way
S
aktiv or passiv output
output loop
300 3-way
S
Output Loop powered
12...60 V DC
300 3-way
S
9...60 V DC
300 3-way
S
24 V DC
24 V DC
24 V DC
300 3-way
300 3-way
300 3-way
S
S
S
2028820000
HART®- transparent
HART®- transparent
HART®- transparent
Limit value monitoring
Measuring transducer
Through hole current converter
Through hole current converter
Through hole current converter
D.19
Signal converters
ACT20P – Universal measurement converter
High process reliability
Thanks to the high level of galvanic isolation
amounting to 4 kV (600 V rated voltage), secure
operation is guaranteed.
N9
Flexible supply
The wide supply range from 24 V UC to 230 V
UC opens up a diverse range of applications for
the ACT20P Pro DCDC II.
D
Precise data recording
Measurement data is converted and transmitted
with an accuracy level of 0.05 %.
Universal solution
Due to the multitude of adjustable measurement
ranges from ± 300 V DC or ± 100 mA DC, the
input range can be deployed in an extremely
broad spectrum of applications.
D.20
2028820000
ACT20P – Universal measurement converter
Universal DC isolation amplifier
ACT20P-PRO DCDC II-S
Signal converters
• Universally configurable input and output for voltage/
current
• Active or passive output
• Universal voltage supply 24..230 V AC/DC
• 3-way isolation
• Convenient configuration on the device with DIP
switches or by means of clear-text display + buttons,
without reference source.
D
Technical data
Input
Input voltage
Input current
Input resistance, current
Input resistance, voltage
Output
Output voltage
Output current
load impedance voltage
load impedance current
Offset voltage
Cut-off frequency (-3 dB)
General data
Galvanic isolation
Accuracy
Temperature coefficient
Configuration
Power consumption
Step response time
Supply voltage
Insulation coordination
Rated voltage
Standards
Insulation voltage
Impulse withstand voltage
Pollution degree
Overvoltage category
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
configurable, ±20 mV…±300 V
configurable, ± 0.1mA...± 100 mA
< 5 mA: approx. 100 Ω; >5 mA: approx. 5 Ω
approx. 1 MΩ
adjustable, 0...±10 V
adjustable, 0...±20 mA
≥ 1 kΩ
≤ 600 Ω
< 10 mV
> 10 kHz/ < 10 Hz
3-way isolator, between input ⁄ output ⁄ supply ⁄ relay
< 0.05 % of measuring range
≤0,01% des Messbereichs⁄°C
DIP switch, or via display and push-buttons
≤2.3 W
≤50 ms, ≤50 µs
24…230 V DC ±20 %, 24…230 V AC ±10 % @ 48…62 Hz
600 V
EN 60079-0, EN 60079-15, EN 61010-1:2011, EN 61140, EN 613261, UL 61010-1, SN29500 for MTBF
4 kVeff, input ⁄ output ⁄ power supply
5 kV (1.2/50 µs)
2
II
Screw connection
2.5 / 0.5 / 2.5
/ 12.5 / 117.2
Ordering data
Type
ACT20P-PRO DCDC II-S
Qty.
1
Order No.
1481970000
Note
Accessories
Note
2028820000
D.21
Signal converters
ACT20P – Universal measurement converter
D
All-purpose inputs combined with output loop supply
ACT20 signal converters are equipped for diverse applications
When it comes to recording analogue measured values,
compliance with safety regulations and maximum precision
are basic prerequisites for industrial plants. Basic security
functions, such as switching units on and off, monitoring
actuators or controlling temperature and pressure, require
the support of high-precision signal converters.
With our ACT20X and ACT20P products, we are providing
you with universal devices that will reliably isolate and
convert signals from intrinsically safe or safe zones. Thanks
to the integrated output current loop, the modules do not
require any additional external power supply and can also
be easily used in remote control boxes. Integrated in an
enclosure that measures a mere 12.5 mm wide, the signal
converters take up very little space on the DIN rail.
The latest addition to our ACT20X series is characterised
by high precision and compliance with all the safety
requirements for use in Ex zones 0, 1 and 2. Also, the
ACT20P ITX+ offers extended input properties, such as
measurement of +/-300 V AC/DC voltages and currents of
up to+/-5 A DC. It even features a digital output for indicating
limit values.
The great advantage of a signal converter in applications
involving direct, on-site recording of measured values from
temperature and pressure sensors is that it can be used
independently of the power supply
Your
special
advantages:
D.22
Predestined for field use
The combination of all-purpose input and output loop supply makes the ACT20X a unique
product solution for the process industry and plant manufacture. But the advantages of this
solution really do come into their own especially when the device is used e.g. in remote cabinets
in the mining industry – both above and below ground – or in overburden materials handling.
2028820000
ACT20P – Universal measurement converter
Universal converter with digital output
ACT20P-UI-AO-DO-LP-S
Signal converters
• Independent of external supply thanks to output looppowered supply
• All-purpose usage thanks to versatile input functions
• Simple software configuration
• Digital output for versatile limit value setting
3RW
57'5HV
7&
&XUUHQW
$
P$
P9
9ROWDJH
9
²
9
9
²
9
/RRS3RZHUHGP$
/RRS3RZHUHGP$
$ODUPYH
$ODUPYH
D
Technical data
Input
Sensor
Input voltage
Input current
Potentiometer
Output
Type
Output current
load impedance current
Output (digital)
Type
Rated switching voltage
Rated switching current
General data
Galvanic isolation
Accuracy
Configuration
PT100 / 2-/3-/4-wire, PT1000/2-/3-/4-wire, PT200, N120,
Thermocouples: B, E, J, K, L, N, R, S, T, U, Potentiometer
configurable, ± 300 V DC (min. measurement range 100 V), 0…300 V
AC (min. measurement range 100 V)
configurable, ± 5 A DC (min. measurement range 0.5 A)
1.2…500 kΩ
Output-loop powered
4...20 mA, 20…4 mA, Current loop
typ. 700 Ω @ 24 V DC
Transistor, open collector
≤ 30 V DC
20 mA
2-way isolator, between input/output
< 0.1 % of measuring range
With FDT/DTM software
Step response time
Supply voltage
Insulation coordination
Rated voltage
Standards
Insulation voltage
Impulse withstand voltage
Pollution degree
Overvoltage category
450 ms
Output loop powered, (10…45 V)
Dimensions
Clamping range (nominal / min. / max.)
Depth / Width / Height
Note
Screw connection
2.5 / 0.5 / 2.5
113.6 / 12.5 / 119.2 mm
300 Veff
DIN EN 61326-1, DIN EN 61010-1
3.51 kV between input and output
4 kV (1.2/50 µs)
2
III
Ordering data
Type
ACT20P-UI-AO-DO-LP-S
Note
Qty.
1
Order No.
1453210000
CBX200 USB configuration adapter - 8978580000
Accessories
Note
2028820000
D.23
Signal converters
ACT20P – Universal measurement converter
Simple operation
The intuitive connection system with release
levers makes it easier to maintain the device and
to detach lines.
Versatile application options
The ACT20P-WavePak functions over a large
temperature range and can be used reliably in
an extremely wide range of application areas.
+70 °C
to
–25 °C
D
High process reliability
The high level of galvanic isolation of 4 kV at
300 V rated voltage guarantees safe operation.
N9
D.24
2028820000
ACT20P – Universal measurement converter
Signal converter
ACT20P-AI-AO-DC-S
Signal converters
• Isolation and conversion of DC signals
• 24 V - sensor supply
• Configuration via DIP switch/button
• Supply 12-60 V DC
• 3-way isolation
,QSXW
&XUUHQW
2XWSXWVLJQDOV
9ROWDJH
9
7[
&XUUHQW9ROWDJH
&XUUHQW9ROWDJH
3RZHU6XSSO\
/LYH3RVLWLYH
1HXWUDO1HJDWLYH
D
Technical data
Input
Input voltage
Input current
Input resistance, current
Input resistance, voltage
Sensor supply
Output
Output voltage
Output current
load impedance voltage
load impedance current
Offset voltage
General data
Galvanic isolation
Linearity
Temperature coefficient
Configuration
Step response time
Supply voltage
Insulation coordination
Standards
EMC standards
Insulation voltage
Impulse withstand voltage
Overvoltage category
Dimensions
Clamping range (nominal / min. / max.)
Depth / Height / Width
Note
configurable, 0…11 V (min. measurement range 2V)
configurable, 0…22 mA (min. measurement range 4 mA)
100 Ω
≥ 1 MΩ
24 V DC
adjustable, 0...11 V, min. output range 2V
adjustable, 0...22 mA, min. output range 4 mA
≥ 500 kΩ
≤ 1kΩ
≤ 20 mV
3-way isolator, between input ⁄ output ⁄ supply
< ± 0.1 % of signal range, Typ. ± 0.05 % of signal range
< 0.05 % / °C
DIP switch, Keys and LED display
350 ms
12...60 V DC
IEC 61326-1:2012, UL 61010-1:2012, 3rd Edition
IEC 61326-1
2 kV inputs / outputs
4 kV (1.2/50 µs)
III
Screw connection: pluggable
1.5 / 1 / 2.5
113.7 / 117.2 / 12.5 mm
Ordering data
Type
ACT20P-AI-AO-DC-S
Qty.
1
Order No.
1477420000
Note
Accessories
Note
2028820000
D.25
ACT20P – Signal splitter
Signal converters
Signal splitter
ACT20P-CI-2CO
• Isolation and splitting of DC signals
• Passive transmitter or active current input
• 3-way isolation
• HART® - transparent
IN
11
11
12
12
OUT
I
2 wire
21
transmitter
Current 3 wire
source transmitter
D
22
PLC
823.6
I
61 62
24 V
DC
passive
passive
230 V
AC
Technical data
Input
Input signal
Input current
Voltage drop, current input
Voltage drop
Output
Output current
load impedance current
General data
Configuration
Supply voltage
Accuracy
Step response time
Temperature coefficient
Ambient temperature
Insulation coordination
EMC standards
Insulation voltage
Test voltage
Impulse withstand voltage
Pollution degree
Overvoltage category
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
2-/3-wire transmitter, HART digital signal
0...20 mA, 4…20mA
≥ 17V @20mA
≤1V
0...20 mA, 4...20 mA
< 300 Ω
none
20…30 V DC
< 0.1 % of end value
≤ 0,5 ms
80 ppm/K
EN 61010-1:2011, UL 61010-1, EN 61326-1
2 kV inputs / outputs / power supply
300 V
4 kV (1.2/50 µs)
2
III
Screw connection
2.5 / 0.5 / 2.5
113.7 / 12.5 / 117.2
Ordering data
Type
ACT20P-CI-2CO
Qty.
1
Order No.
7760054115
Note
Accessories
Note
D.26
2028820000
ACT20P – Signal converter
Signal converter
ACT20P-CI-CO
Signal converters
• Isolation of DC signals
• Passive transmitter or active current input
• 3-way isolation
• HART® - transparent
IN
11
11
12
12
OUT
I
passive
PLC
2 wire
21
transmitter
Current 3 wire
source transmitter
22
51 52
24 V
DC
230 V
AC
Technical data
Input
Input signal
Input current
Voltage drop, current input
Voltage drop
Output
Output current
load impedance current
General data
Configuration
Supply voltage
Accuracy
Step response time
Current consumption
Temperature coefficient
Ambient temperature
Insulation coordination
EMC standards
Insulation voltage
Test voltage
Impulse withstand voltage
Pollution degree
Overvoltage category
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
D
2-/3-wire transmitter, HART digital signal
0...20 mA, 4…20mA
≥ 17V @20mA
≤1V
0...20 mA, 4...20 mA
≤ 550 Ω
none
20…30 V DC
< 0.1 % of end value
≤ 0,5 ms
≤60 mA (24V power supply, 20mA output)
80 ppm/K
EN 61010-1:2011, UL 61010-1, EN 61326-1
2 kV inputs / outputs / power supply
300 V
4 kV (1.2/50 µs)
2
III
Screw connection
2.5 / 0.5 / 2.5
113.7 / 12.5 / 117.2
Ordering data
Type
ACT20P-CI-CO
Qty.
1
Order No.
7760054114
Note
Accessories
Note
2028820000
D.27
ACT20P – Signal converter
Signal converters
Signal converter
D
ACT20P-2CI-2CO-12
• Isolation of DC signals
• Passive input
• 2 channels in one module
• 3-way isolation
• HART® - transparent
DNWLY ,1
,
,1
,
SDVVLY
287
,
3/&
287
,
9
'&
VXSSO\
9
$&
SDVVLY
Technical data
Input
Input current
Voltage drop
Output
Output current
load impedance current
General data
Configuration
Supply voltage
Accuracy
Step response time
Temperature coefficient
Ambient temperature
Insulation coordination
EMC standards
Insulation voltage
Test voltage
Impulse withstand voltage
Pollution degree
Overvoltage category
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
0...20 mA, 4…20mA
≤1V
0...20 mA, 4...20 mA
< 300 Ω, per channel
none
20…30 V DC
< 0.1 % of end value
≤ 0,5 ms
80 ppm/K
EN 61010-1:2011, UL 61010-1, EN 61326-1
2 kV inputs / outputs / power supply
300 V
4 kV (1.2/50 µs)
2
III
Screw connection
2.5 / 0.5 / 2.5
113.7 / 12.5 / 117.2
Ordering data
Type
ACT20P-2CI-2CO-12
Qty.
1
Order No.
7760054117
Note
Accessories
Note
D.28
2028820000
ACT20P – Limit value monitoring
Signal converters
Limit monitoring with simple configuration
ACT20P identifies even the smallest deviations
Reliable monitoring of parameters such as pressure, flow and
temperature plays an important role, especially for power
applications and in the process industry. In this regard,
individual specifications and standards define the limits to
be observed for smooth process flows.
D
Our ACT20P trip amplifier enables a precise monitoring
solution to be set up for your process signals. Easily
configured via FDT/DTM software or also directly on the
device, the universal module can be used in many ways. The
universal input range as well as the robust design support a
wide temperature range.
The trip amplifier is characterised by high reproducibility and
reliability. Thanks to its wide range of alarm functions, it can
identify and accurately report even the smallest deviations.
Effective control of threshold limits for the process industry - our
trip amplifiers offer an especially precise solution that responds
rapidly and correctly in the event of deviations
Your
special
advantages:
2028820000
Simple configuration
Use the buttons on the 7-segment display to configure the
ACT20P monitoring module extremely quickly. The manufacturerindependent FDT/DTM software also facilitates configuration.
D.29
Signal converters
ACT20P – Limit value monitoring
Universal input
The universal input range covers
DC currents up to 5 A and voltages up to 300 V,
2/3-wire RTD, thermocouples, resistors and
potentiometers to 500 kΩ.
8,
5ϑ
D
36
Numerous alarm functions
Window alarm, alarm delay, wireline break
detection and hysteresis are just some of
the features with which the trip amplifier
provides the best conditions for each process
requirement.
Configured directly at the device
A 7-segment display and LEDs support the
direct configuration by push buttons and
potentiometer.
High temperature stability
Thanks to the extended temperature range from
–20 °C to +70 °C, the robust monitoring module
can be used in any environment.
ƒ&
WR
²ƒ&
D.30
2028820000
ACT20P – Limit value monitoring
Universal limit-value monitoring
ACT20P-UI-2RCO-DC-S
Signal converters
• Universally configurable input for temperature, voltage,
current, potentiometer, resistance
• 2 independent relay outputs with multiple limit value
functions: window alarm, upper/lower limits, hysteresis,
delay, etc.
• Configuration on the device from 7-segment display or
via FDT/DTM software
• External power supply 9…60 V DC
9,3RW57'7&
J9,
7[
9
36
9
Technical data
Input
Sensor
Input measurement range
Input voltage
Input current
Output (digital)
Type
Rated switching current
General data
Galvanic isolation
Accuracy
Temperature coefficient
Configuration
Power consumption
Step response time
Supply voltage
Ambient temperature (operational)
Insulation coordination
Rated voltage
Standards
Insulation voltage
Impulse withstand voltage
Pollution degree
Overvoltage category
Dimensions
Clamping range (nominal / min. / max.)
Depth / Width / Height
Note
D
Thermocouples: B, E, J, K, L, N, R, S, T, U, PT100/2-/3-wire, PT200,
PT1000, N120, Cu 10, Potentiometer: 1.2 kΩ - 500 kΩ, Resistance:
0 - 1.5 kΩ, Resistance: 0 - 12 kΩ, Resistance: 0 - 750 Ω
configurable, Thermocouple type J -100…+1200°C, Thermocouple
type K -200…+1370°C, PT100 -200…+850 °C
configurable, ±150 mV DC, ± 600mV DC, ±30 V DC, ±300 V DC
configurable, ± 25 mA DC, ±5 A DC
2 CO contacts
200mA @ 110Vdc, 6A @ 24Vdc / 240Vac
3-way isolator, Input to supply ⁄ Alarm 1 ⁄ Alarm 2
< 0.05 % of measuring range
< 0.02 °C of measuring range / °C
With FDT/DTM software, or via 7-segment display, push-buttons and
rotary encoder on the device itself
≤ 3.5 W
450 ms
9...60 V DC
-20 °C...70 °C
300 Veff
DIN EN 61326-1, DIN EN 61010-1
3 kV
3 kV (1.2⁄50µs)
2
III
Screw connection
2.5 / 0.5 / 2.5
113.6 / 22.5 / 117.2
Ordering data
Type
ACT20P-UI-2RCO-DC-S
Qty.
1
Order No.
7940045760
Note
Accessories
Note
2028820000
CBX200 USB configuration adapter - 8978580000
D.31
Signal converters
ACT20P – Current measuring transducer
Simple and quick configuration
DIP switches and potentiometers are located
on the front, which means they’re quickly
accessible even when installed.
Precise measured values
The real-value effective procedure allows you
to record the connected load’s real power
consumption, so you can reliably identify when
levels exceed or fall below the nominal current.
,
W
D
Easy to install
The asymmetrical cable bushing makes it
easier to feed through the power cable and
permits precise measurement on an extremely
small space.
22.5 mm
High process reliability
Reliable function thanks to a galvanic four-way
isolation and an impulse withstand voltage of
6.4 kV according to IEC 61010-2-201
N9
D.32
2028820000
ACT20P – Current measuring transducer
ACT20P-CMT
• Measuring and monitoring of AC/DC current
• Input/output electrically isolated
• Input and output ranges are adjustable
• Contact-free through-hole technology
• Relay output for limit value alarm with switching
threshold, delay, hysteresis
Output signals *
Input signal
Current
Current, voltage
*
44
Output
Output
43
Supply
+
I for AC
42
mA
+
Input
-
V
I for DC
-
41
Output signal
Signal converters
Current-measuring transducer
Power supply
Relay
24
+16.8...31.2 V DC
54
Output
Output
23
22
Ps
U/I
analog
output
Technical data
Input
Input measurement range
52
Input
CO
21
51
&XUUHQW
VLJQDO
configurable, 0…1/5/10 A AC (RMS) or DC
GND
53
Supply
+LJKDODUP
t
D
t
+LJKDODUPVHWSRLQW
+\VWHUHVLV
Input signal
Input frequency
Output (analogue)
Output voltage [output analogue]
Output current [output analogue]
Load resistance voltage [output analogue]
Load resistance current [output analogue]
Output (digital)
Type
Rated switching current
Max. switching voltage, AC
General data
Galvanic isolation
Accuracy
Configuration
Step response time
Temperature coefficient
Supply voltage
Insulation coordination
Rated voltage
Standards
Impulse withstand voltage
Test voltage
Pollution degree
Overvoltage category
Current-carrying cable in feed-through hole, Diameter 10.5 mm
AC: 15…700 Hz
adjustable, 0...10 V, 2…10 V, 0...5 V, 1...5 V, -5…+5 V, -10...+10 V
adjustable, 0...20 mA, 4...20 mA, -20…+20 mA
≥ 10 kΩ
≤ 600 Ω
W!WDG
2XWSXW
WDG$ODUPGHOD\
/RZDODUP
W!WDG
/RZDODUPVHWSRLQW
W
2XWSXW
W
WDG$ODUPGHOD\
7LPH
WDG$ODUPGHOD\
5HOD\GHHQHUJL]HG/('\HOORZ´2))µ 5HOD\HQHUJL]HG/('\HOORZ´21µ
',3VZLWFK6
&XUUHQWLQSXWUDQJH $
█
$
$
$
█
█
$
$
$
█
█
$
300 V ACrms
IEC 61010-1:2010, 3rd Edition, IEC 61010-2-201:2013, 1st Edition,
EN 61326-1
6.4 kV (1.2/50 µs)
4 kV
2
III
1,5 / 0,5 / 2,5
113,6 / 22,5 / 117,2
WWDG
+\VWHUHVLV
0HDVXULQJPHWKRG
7UXH506
$ULWKPHWLFDYHUDJH
$ODUPGHOD\WLPH
V
V
V
V
0HDVXULQJUDQJH
PRQLWRULQJ
<HV
1R
Dimensions
Clamping range (nominal / min. / max.)
Tiefe / Breite / Höhe
Note
7LPH
WDG$ODUPGHOD\
&XUUHQW
VLJQDO
Relay, 1 CO contact, Open or closed-circuit principle, with alarm delay
time (configurable) 0 s ⁄ 2 s ⁄ 5 s ⁄ 10 s
6A
250 V
4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
< 0.5 % of end value
DIP switch and potentiometer, for thresholds (overcurrent ⁄
undercurrent), delay and hysteresis
< 220 ms (10...90 %)
≤ 200 ppm/K
18...30 V DC
WWDG
█
█
█
█
█
2XWSXWUDQJH
9
9
9
9
9
9
P$
P$
P$
',3VZLWFK6
█
█
█
█
█
█
█
█
█
█
█
█
$ODUPUHOD\DFWLRQ
(QHUJL]HG
'HHQHUJL]HG
$ODUPK\VWHUHVLV
$ODUPW\SH
+LJKDODUP
/RZDODUP
█
█
█
█
2XWSXWHUURUDFWLRQ
8SVFDOH
'RZQVFDOH
7UDQVIHUIXQFWLRQ
1RUPDO
,QYHUVH
█
█
█
21
$&73&07$25&6
$&73&07$25&6
$&73&07$25&6$&73&075&6
Ordering data
Input measurement range 0...5/10 A
Input measurement range 0...20/25/30 A
Input measurement range 0...40/50/60 A
Input measurement range 0...40/50/60 A
Note
Type
ACT20P-CMT-10-AO-RC-S
ACT20P-CMT-30-AO-RC-S
ACT20P-CMT-60-AO-RC-S
ACT20P-CMT-60-RC-S
Qty.
1
1
1
1
Order No.
1510470000
1510540000
1510440000
1510390000
Accessories
Note
2028820000
D.33
Signal converters
ACT20P – Bridge measuring transducer
ACT20P Strain gauge transmitter
The ACT20P Bridge converts load cell/strain gauge
measurement signals to standard analogue signals.
The ACT20P family offers the customer precise and
functional signal converters in a compact design. The
ACT20P Bridge is the first product from this new line of
signal converters.
D
D.34
Load cells, with integral strain gauges, are used for weighing
and load measurements throughout factory and process
automation, in such applications as batch and recipe control,
silo contents for granular products, bag weighing, engine
strain measurements, and tank level.
The strain gauges, within the load cell, are film resistors in
a measurement bridge network, which deform with load
changes and create a varying millivolt output from the
bridge. The ACT20P Bridge reads these signals and converts
them to a standard signal 0(4) – 20 mA or 0 – 10 V.
The high input to output isolation provided protects the
control PLC against signal line interference. A digital input
representing the “empty“ condition of the container (tare
function) is a standard feature which zeroes the output of the
ACT20P Bridge.
Features
• Adjust to load cells using push button
•Easy tare function using the integrated control input
•Intelligent pluggable connection method
The release lever simplifies maintenance and enables the
connection to be unplugged without any wire damage.
•Integrated captive coding with the unique
“auto-set“ function
2028820000
Signal converters
ACT20P – Bridge measuring transducer
Exact measurement
5.000047
The input with 6-conductor connection
and very high accuracy (0.05 % of the
measurement range) enables precise
signal processing.
Conversion
D
Conversion of the bridge voltage in
standardised analogue signals.
Tare calibration
Simple calibration of the empty (tare)
weight can be done on-site by using
the button under the front plate or
with an external connection via a PLC
output.
On-site calibration
Simple and reliable calibration on-site.
The ACT20P Bridge is adjusted to the
different load cells by means of a push
button behind the hinged panel.
Protection
Protection against noise from the field.
The 3-way isolation separates the
input, the voltage supply and the
output with 5.7 kV isolation voltage.
Strain gauge transmitter
2028820000
D.35
Signal converters
ACT20P – Bridge measuring transducer
ACT20P Bridge measuring transducer
Bridge measuring transducer for reading from load
cells
D
General
The ACT20P Bridge is a DIN rail mounted, signal conditioner
for industrial measuring bridges. It provides a precise excitation voltage for the bridge, and converts the input measurement to an isolated current/voltage signal. Bridge measuring
transducers are used for various measurements like weight,
force, tension, pressure, torque, and deflection.
Bridge excitation supply
Voltage sense connections are provided so that the
excitation voltage can be measured at the bridge. Known
as ‘remote sensing’ this method compensates for cabling
and contact resistance errors. It is recommended for all
new installations or where an upgrade is possible. Remote
sensing wiring requires three twisted pairs.
TARE adjustment
The installed strain gauge is normally subjected to an initial
load independent of the measurement taken. The TARE
connection allows you to correct for this initial loading by
operating a switch. Alternatively there is a button on the
front of the unit (under the front cover) that performs the
same function. Press for two seconds to correct for the initial
load (the ‘CAL HI’ LED will light for one second).
Gauge factor
Every strain gauge has a ‘gauge factor’ which gives the
output voltage at full-scale for a one volt excitation voltage
(given in mV/V). You multiply this by the bridge excitation
voltage to get the output voltage when the gauge is fully
loaded. For example, a load cell with 10 V excitation and
2 mV/V gauge factor will give 20 mV when fully loaded.
The meaning of a 20 mV output depends on the type of the
strain gauge. If it was designed to measure 0-1000 Kg then
20 mV indicates a 1000 Kg load.
Setup
The ACT20P Bridge has internal switch settings that
determine the excitation voltage (5 V or 10 V) and Input
range limits. Select the appropriate settings from the table
below. Once you have set the DIP switches, you simply
calibrate the unit to the input and output range for your
application.
Calibration
There are three options for calibrating the ACT20P Bridge:
•Kalibrierung über einen Messbrückensimulators
(Bench calibrate using a bridge simulator (if you know the
gauge factor)
•Calibrate on-site by loading the actual installed strain
gauge
•Bench calibrates using a mV source (if you know the
gauge factor).
For more information please read the manual from the
web page: www.weidmueller.com
>6HQVH@
>([FLWDWLRQ@
>ï([FLWDWLRQ@
>ï6HQVH@
>ï6LJQDO@
>6LJQDO@
>([FLWDWLRQ@
>ï([FLWDWLRQ@
$&73%ULGJH
>ï6HQVH@
>6HQVH@
,QSXWFRQQHFWLRQVIRU$&73%ULGJHZLWK
VZLWFKHVVHWIRU:LUHPHDVXUHPHQW
$&73%ULGJH
,QSXWFRQQHFWLRQVIRU$&73%ULGJHZLWK
VZLWFKHVVHWIRU:LUHPHDVXUHPHQW
D.36
2028820000
ACT20P – Bridge measuring transducer
Configurable
ACT20P-BRIDGE-S
Signal converters
Bridge measuring transducer for reading from load cells
• 3-way isolation
• Supply for measuring bridges up to 4 x 350 Ω
• Simple calibration of the tare weight using external
switch or PLC input
• Input and output ranges adjustable via DIP switch
Strain
Gauge
+ 23
24 Tare
excitation + 21
13
sense +
signal signal +
0/4...20 mA
I +
11
12
V/I
0...10 V
41
42
-
44
mA test point +
excitation - 22
14
sens sense
PS
43
mA test point -
10...60 V DC
+ 54
53
Technical data
Front panel DIP Switch settings
Input
Type
Bridge sensitivity
Input measurement range
Input resistance
Sensor supply
Bridge supply voltage
Output
Type
Output voltage / Output current
Load impedance, voltage/current
General data
Configuration
Supply voltage
Power consumption
Linearity
Repeat accuracy
Humidity
Temperature coefficient
Long-term drift
Step response time
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Pollution degree
Overvoltage category
Insulation voltage
Resistance measuring bridge
1.0 mV / V to 5.0 mV / V
± 10 mV / ± 20 mV / ± 30 mV / ± 50 mV (adjustable)
> 1 MΩ
120 mA @ 10 V (= 4 x 350 Ω bridge resistors)
5 V or 10 V
Voltage and current output (configurable)
0 ...11 V (adjustable) / 0...22 mA (adjustable)
600 Ω / ≤ 600 Ω
Switch
1
2
3
4
5
6
7
8
Action if On
10 V Excitation
mA Output
10 mV Span
20 mV Span
30 mV Span
50 mV Span
4-wire Measurement
D
Action if Off
5 V Excitation
Voltage Output
Turn off for other ranges
6-wire Measurement
Connections
DIP switch
10…60 V DC
3 W @ 24 V DC
Typically ± 0.05 % of signal range
± 0.05% of signal range
10...90 % (no condensation)
typ. 0.005 % / °C
0.1 % / 10.000 h
< 400 ms (10…90 %)
-40 °C...70 °C
EAC; GOSTME25
Terminal
11
12
13
14
21
22
23
24
41
42
43
44
44
54
53
DIN EN 61010-1, DIN EN 61000-4-2
EN 61326
300 Veff
4 kV (1.2/50 µs)
2
III
5.7 kV (input / output, input / supply)
Signal
Signal −
Signal +
Sense +
Sense −
Excitation +
Excitation −
Tare +
Tare −
mA Output −
Output +
mA-Test Point −
Voltage Output −
mA-Test Point +
+
−
Input signal
Bridge Excitation Voltage
External Tare switch
Output signal
Power Supply
Screw connection
2.5 / 0.5 / 2.5
113.6 / 22.5 / 117.2
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
Ordering data
Screw connection
Type
ACT20P-BRIDGE-S
Qty.
1
Order No.
1067250000
Note
Accessories
Note
2028820000
D.37
Signal converters
WAVESERIES – Overview
WAVESERIES – Signal converters
Isolation and conversion of analogue signals –
enclosed in a rail-mounted WAVEBOX housing
D
WAVESERIES products are well suited for users seeking
an analogue signal conversion solution. Weidmüller‘s
WAVESERIES integrates a wide variety of functions into a
compact, space-saving design. This product line covers a
broad range of products suitable for many different analogue
signal conditioning applications.
• Passive isolation amplifier for standard analogue signals
•Active isolation amplifier for standard analogue signals
with 2-way or 3-way isolation
•Isolating signal converters for temperature (RTDs /
thermocouples), resistance, potentiometer, frequency,
AC/DC currents up to 60 A, and AC voltages up to 450 V.
•Measuring transducer for measuring AC currents up to
500 A
•Signal converters for all common input signals, with
configuration (either DIP switch or with software)
•Signal converters with analogue and relay outputs, fully
configurable via interface and software
Service
No tools are required when removing the PCB from the housing. Simply push in
the locking clips on the head piece and then pull out the upper section along with
the connections and the PCB.
Saves time
The ZQV 2.5N cross-connector can be used to connect
the housing together in order to bridge the power supply
between the modules.
Security
You must ensure the presence of “protective separation“ in accordance with
EN50178. The WAVESERIES products are able to fulfil these requirements
completely.
Flexibility
The BLZ/ BLZF pluggable screw and tension-clamp connections
offer you the best flexibility. Coding elements can be used
(without loss of poles) to make sure that the wrong plug
cannot be inserted.
Protection
The WAVEBOX housing is made from recyclable plastics. It is available in widths
of 12.5, 17.5, 22 or 45 mm. Practically no tools are required during installation.
All requirements and EMC are met. The integrated ventilation slits ensure that
sufficient heat dissipation takes place.
D.38
2028820000
Signal converters
WAVESERIES – Overview
D
Universal signal converter
2028820000
3-way isolator, configurable
Frequency converters
3-way isolator
Current monitoring
2 way isolator,
Output Loop Powered
Voltage monitoring
Passive Isolators, Input and
Output Loop Powered
Bridge measurement isolator/
converter
Temperature transmitters
Serial interface isolation converter
D.39
Signal converters
WAVESERIES – Universal signal converters and trip amplifiers, configurable
WAVE TTA – one module fits all ...
In the case of signal processing this is a big benefit. The
maintenance engineer who hasn’t got the right spare
isolator or transmitter, and has to run part of the plant on
manual control for a day or two before the replacement
arrives understands this. It wastes his time and money. So
Weidmüller has designed a signal processor with unique
flexibility.
D
In one module the Wave TTA is an intelligent signal
•Isolator
• Convertor
•Transmitter
• Lineariser
• Trip-amplifier
The new WAVE TTA is a “universal“ Transmitter TripAmplifier. It is part of Weidmüller’s well-established
WAVESERIES family of analogue signal conditioners,
which are widely used in process and factory automation
applications.
The TTA is unique. It has a combination of high performance
and exceptional configurability. Designed for process
industry applications, the TTA will work accurately and
stably over a wide ambient temperature range, and over a
wide supply voltage range, and with most types of sensor
inputs. For 2-wire current transmitters 24 V DC power is
provided. Alternatively the TTA can be a passive input for the
current source.
For linearised and/or isolated analogue outputs, the user has
a choice of standard or variable DC milliamps and voltage
ranges. These can be set as either direct or reverse acting.
The user can also select upscale or downscale output in the
event of a sensor break or an open circuit in the input.
The TTA provides 2 changeover-relay outputs which can be
independently set, for use as high and low level alarms or
control points.
Configuring the versatile TTA to change input and output
parameters is simple, and performed from a computer via an
interface (CBX200 USB).
Powering the TTA is flexible too. When the auxiliary supply
is anything between 18 and 264 V (AC or DC), one module
can take it.
Physically, the TTA comes in a black WAVESERIES housing
with a flammability class V0 acc. UL 94, for mounting on
TS 35 DIN rail. Pluggable connectors, allow screw or tension
clamp wiring. A screwdriver-releasable front flap gives
access to the configuration interface socket.
Most commonly used temperature sensors and DC inputs
are accepted, and the TTA also allows the user to define his
own characteristics, so special sensor types and linearisation
can easily be acommodated.
To help simplify installation and loop commissioning, test
terminals are provided to permit input and output signal
checks without removing cabling.
D.40
2028820000
Signal converters
WAVESERIES – Universal signal converters and trip amplifiers, configurable
The free software TTA-Set allows fast and uncomplicated
configuration of the WAVE TTA .
Easily adjustable measurement window, transmit functions
and switching thresholds, as well as different thresholds and
alarms for faults.
Universal input signals
•Temperature signals (such as RTDs), One module integrates
thermocouples and potentiometers, frequency transmitter,
DC voltage signals and DC current signals.
Current source or loop powered input
•For DC current inputs the TTA can be used
with either a passive input, or provide power
for a two-wire transmitter.
Wide AC/DC power input
(18-264 V AC/DC)
User-definable characterisation
•If none of the standard input linearisation
options suit the sensor, a special curve
can easily be created.
D
Inputs & outputs configurable via computer
•The range of configurability of the TTA is
remarkable – and made easy using TTA SET
software, in conjunction with the CBX200 USB
interface.
Both analogue and relay outputs
•In one module the TTA integrates adjustable
alarm or control outputs from mechanical relays,
as well as it‘s proportional analogue output.
Wide ambient temperature range
(–40 to 70 °C)
•Mounting the TTA outside in the field is no
problem. It‘s ambient temperature range means
it can also be field enclosure mounted.
High accuracy and temperature stability
•The Wave TTA offers superior performance and
minimises losses for data acquisition systems,
with its output accuracy typically < 0.1 %, and
temperature stability < 0.01 %/K
Milliamp signal testing without removing
cables
•The current and voltage inputs can be tested
using a supplemental test contact without
loosening the existing wiring.
UL Class I Div.2 and ATEX Zone 2 approvals
2028820000
D.41
WAVESERIES - Universal signal converter and trip amplifier, configurable
Signal converters
WAVE TTA
WAS6 TTA / WAZ6 TTA
• Input and outputs can be configured on PC with the
TTA-SET software, download at www.weidmueller.
com
• Universal input signals
• Loop-powered or passive input
• Pluggable connection terminals
Analogue Inputs
3-Ports Isolation
J V, I
V, I
+24 V DC
PS
Relay
Channel 1
Relay
Channel 2
Output
0 ... 11 V /
0 ... 22 mA
18-264 V AC/DC supply
D
Technical data
Typical functions
Input
Sensor
Thermocouples: B, E, J, K, L, N, R, S, T (IEC 60584), PT100, PT1000,
(EN 60571) Ni100, Ni1000, (JIS1604), Cu10, Cu25, Cu50, Cu100
(DIN 43760) 2-/3-/4-wire
100 Ω...100 kΩ
10 Ω…5 kΩ
2 Hz…100 kHz
-200...500 mV (min. 4 mV span), -20...50 V DC (min. 0.5 V span)
-20...50 mA (min. span 0.4 mA)
24 V DC / 22 mA
Potentiometer
Resistance
Input frequency
Input voltage
Input current
Sensor supply
Output analogue
Output voltage
Output current
Load impedance, voltage/current
Signal output
Transmit function
Output digital
Type
Switching voltage AC, max. / DC, max.
Continuous current
General data
Configuration
Supply voltage
Power consumption
Accuracy
Temperature coefficient
Isolator
I
I, V
PS
Converter
f, I, V
Adjustable between -10...+10 V (min. span of 2.5 V)
Adjustable between 0...20 mA (min. span of 5 mA)
> 10 kΩ @ 0...10 V / > 20 kΩ @ -10...+10 V / < 700 Ω
direct or inverted
Linear, x1/2, x3/2, x5/2 or user-defined curve (101 points)
I, V
PS
Transmitter
2 x 1 CO contact (hard gold-plated)
250 V / 30 V
3 A AC / 2 A DC
J
I, V
PS
TTA Set Software
18...264 V AC/DC
< 3.5 W
< 0.1 % span (DC. RTD); 0.2 % span (or 1 °C) + CJ failure
< 0.1 % / K (DC, RTD); < 0.1 % FSR / K + CJ error 0.07 °C/K
(thermocouples )
/ -40 °C...70 °C / -40 °C...85 °C
50 ms...1 sec (RTD, mV inputs), 110 ms...1 sec (V, mA inputs)
5...95 %, no condensation
CE; cULus; EAC; GL
Ambient temperature / Storage temperature
Step response time
Humidity
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Pollution degree
Overvoltage category
Clearance & creepage distances
Insulation voltage
Lineariser
I, V
I, V
PS
Trip amplifier
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
6 kV
2
III
≥ 5.5 mm (1 mm Input/output)
2.5 kV
J
PS
Ordering data
Type
Screw connection
WAS6 TTA
Tension clamp conn.
WAZ6 TTA
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
D.42
mm²
mm
Screw connection
2.5/0.5/2.5
112.4/45
Qty.
Order No.
1
8939670000
1
8939680000
Tension clamp connection
2.5/0.5/2.5
112.4/45
CBX200 USB configuration adapter - 8978580000
2028820000
WAVESERIES - Universal signal converter and trip amplifier, configurable
WAVE TTA EX
WAS6 TTA EX / WAZ6 TTA EX
Signal converters
• Input and outputs can be configured on PC with the
TTA-SET software, download at www.weidmueller.
com
• Universal input signals
• Loop-powered or passive input
• Pluggable connection terminals
• ATEX 3 G Ex nA IIC T4
• UL Class I, Div.2
Analogue Inputs
3-Ports Isolation
J V, I
V, I
+24 V DC
PS
Relay
Channel 1
Relay
Channel 2
Output
0 ... 11 V /
0 ... 22 mA
18-264 V AC/DC supply
D
Technical data
Typical functions
Input
Sensor
Thermocouples: B, E, J, K, L, N, R, S, T (IEC 60584), PT100, PT1000,
(EN 60571) Ni100, Ni1000, (JIS1604), Cu10, Cu25, Cu50, Cu100
(DIN 43760) 2-/3-/4-wire
100 Ω...100 kΩ
10 Ω…5 kΩ
2 Hz…100 kHz
-200...500 mV (min. 4 mV span), -20...50 V DC (min. 0.5 V span)
-20...50 mA (min. span 0.4 mA)
24 V DC / 22 mA
Potentiometer
Resistance
Input frequency
Input voltage
Input current
Sensor supply
Output analogue
Output voltage
Output current
Load impedance, voltage/current
Signal output
Transmit function
Output digital
Type
Switching voltage AC, max. / DC, max.
Continuous current
General data
Configuration
Supply voltage
Power consumption
Accuracy
Temperature coefficient
Isolator
I
I, V
PS
Converter
f, I, V
Adjustable between -10...+10 V (min. span of 2.5 V)
Adjustable between 0...20 mA (min. span of 5 mA)
> 10 kΩ @ 0...10 V / > 20 kΩ @ -10...+10 V / < 700 Ω
direct or inverted
Linear, x1/2, x3/2, x5/2 or user-defined curve (101 points)
I, V
PS
Transmitter
2 x 1 CO contact (hard gold-plated)
250 V / 30 V
2 A AC/DC
J
I, V
PS
TTA Set Software
24...240 V AC/DC; 24...36 V AC / 24...50 V DC (ATEX Zone 2)
< 3.5 W
< 0.1 % span (DC. RTD); 0.2 % span (or 1 °C) + CJ failure
< 0.1 % / K (DC, RTD); < 0.1 % FSR / K + CJ error 0.07 °C/K
(thermocouples )
/ -40 °C...70 °C / -40 °C...85 °C
50 ms...1 sec (RTD, mV inputs), 110 ms...1 sec (V, mA inputs)
5...95 %, no condensation
CE; cULus; cULusEX; EAC; KEMAATEX
Ambient temperature / Storage temperature
Step response time
Humidity
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Pollution degree
Overvoltage category
Clearance & creepage distances
Insulation voltage
Lineariser
I, V
I, V
PS
Trip amplifier
DIN EN 50178, DIN EN 60079, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
6 kV
2
III
≥ 5.5 mm (1 mm Input/output)
2.5 kV
J
PS
Ordering data
Type
Screw connection
WAS6 TTA EX
Tension clamp conn.
WAZ6 TTA EX
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
2028820000
mm²
mm
Screw connection
2.5/0.5/2.5
112.4/17.5
Qty.
Order No.
1
8964310000
1
8964320000
Tension clamp connection
1.5/0.5/2.5
112.4/17.5
CBX200 USB configuration adapter - 8978580000
D.43
WAVESERIES - DC/DC 3-way isolator
Signal converters
20 kHz limiting frequency
0 (4)...20 mA/0 (4)...20 mA
0...20 mA / 0...10 V
• Signal conversion
• Galvanic isolation between input/output signals and
power supply
• Power supply can be cross-connected using plug-in
jumpers
U/I
U/I
VC
D
Technical data
Input
Input voltage / Input current
Input resistance, voltage/current
Output
Output voltage / Output current
Load impedance, voltage/current
Cut-off frequency (-3 dB)
General data
Configuration
Supply voltage
Power consumption
Accuracy
Temperature coefficient
Step response time
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
/ 0...20 mA, 4…20mA
/ 50 Ω
/ 0...20 mA
/ 50 Ω
/ 0...20 mA, 4...20 mA
/ ≤ 500 Ω
≥ 15 kHz (typ. 20 kHz)
0...10 V /
≥ 2 kΩ /
≥ 15 kHz (typ. 20 kHz)
none
24 V DC ± 25 %
< 1.5 W @ IOUT = 20 mA
< 0.2 % of end value
≤ 250 ppm/K of final value
≤ 40 µs (typ. 30 µs)
0 °C...55 °C
CE; CSA; cULus; EAC
none
24 V DC ± 25 %
< 1.3 W @ IOUT = 5 mA
< 0.2 % of end value
≤ 250 ppm/K of final value
≤ 40 µs (typ. 30 µs)
0 °C...55 °C
CE; CSA; cULus; EAC
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
1.2 kVeff / 5 s
III
2
≥ 3 mm
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
1.2 kVeff / 5 s
III
2
≥ 3 mm
Screw connection
2.5/0.5/2.5
112.4/17.5
Tension clamp connection
1.5/0.5/2.5
112.4/17.5
Screw connection
2.5/0.5/2.5
112.4/17.5
Ordering data
Screw connection
Tension-clamp connection
Type
WAS5 CCC HF 0-20/0-20MA
WAZ5 CCC HF 0-20/0-20MA
Qty.
1
1
Order No.
8447160000
8447170000
Type
WAS5 CVC HF 0-20/0-10V
Qty.
1
Order No.
8447220000
Note
Accessories
Note
D.44
Cross-connector for power supplies and markers – refer to Accessories
Cross-connector for power supplies and markers – refer to Accessories
2028820000
WAVESERIES - DC/DC 3-way isolator
20 kHz limiting frequency
4...20 mA / 0...20 mA
4...20 mA / 0...10 V
UL Class I, Div. 2
U/I
Signal converters
• Signal conversion
• Galvanic isolation between input/output signals and
power supply
• Power supply can be cross-connected using plug-in
jumpers
U/I
VC
D
Technical data
Input
Input voltage / Input current
Input resistance, voltage/current
Output
Output voltage / Output current
Load impedance, voltage/current
Cut-off frequency (-3 dB)
General data
Configuration
Supply voltage
Power consumption
Accuracy
Temperature coefficient
Step response time
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
/ 4...20 mA
/ 50 Ω
/ 4...20 mA
/ 50 Ω
/ 0...20 mA
/ ≤ 500 Ω
≥ 15 kHz (typ. 20 kHz)
0...10 V /
≥ 2 kΩ / ≤ 600 Ω
≥ 15 kHz (typ. 20 kHz)
none
24 V DC ± 25 %
< 1.5 W @ IOUT = 20 mA
< 0.2 % of end value
≤ 250 ppm/K of final value
≤ 40 µs (typ. 30 µs)
0 °C...55 °C
CE; CSA; cULus; EAC
none
24 V DC ± 25 %
< 1.3 W @ IOUT = 5 mA
< 0.2 % of end value
≤ 250 ppm/K of final value
≤ 40 µs (typ. 30 µs)
0 °C...55 °C
CE; CSA; cULus; cULusEX; EAC
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
1.2 kVeff / 5 s
III
2
≥ 3 mm
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
1.2 kVeff / 5 s
III
2
≥ 3 mm
Screw connection
2.5/0.5/2.5
112.4/17.5
Screw connection
2.5/0.5/2.5
112.4/17.5
Ordering data
Screw connection
Tension-clamp connection
Type
WAS5 CCC HF 4-20/0-20MA
Qty.
1
Order No.
8447250000
Type
WAS5 CVC HF 4-20/0-10V
Qty.
1
Order No.
8447280000
Note
Accessories
Note
2028820000
Cross-connector for power supplies and markers – refer to Accessories
Cross-connector for power supplies and markers – refer to Accessories
D.45
WAVESERIES - DC/DC 3-way isolator
Signal converters
20 kHz limiting frequency
0...10 V / 0...20 mA
0...10 V / 4...20 mA
UL Class I, Div. 2
• Signal conversion
• Galvanic isolation between input/output signals and
power supply
• Power supply can be cross-connected using plug-in
jumpers
U/I
U/I
VC
D
Technical data
Input
Input voltage / Input current
Input resistance, voltage/current
Output
Output voltage / Output current
Load impedance, voltage/current
Cut-off frequency (-3 dB)
General data
Configuration
Supply voltage
Power consumption
Accuracy
Temperature coefficient
Step response time
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
0...10 V /
500 kΩ /
0...10 V /
500 kΩ /
/ 0...20 mA
/ ≤ 500 Ω
≥ 15 kHz (typ. 20 kHz)
/ 4...20 mA
/ ≤ 500 Ω
≥ 15 kHz (typ. 20 kHz)
none
24 V DC ± 25 %
< 1.5 W @ IOUT = 20 mA
± 0.2 % of final value
≤ 250 ppm/K of final value
≤ 40 µs (typ. 30 µs)
0 °C...55 °C
CE; CSA; cULus; EAC
none
24 V DC ± 25 %
< 1.5 W @ IOUT = 20 mA
± 0.2 % of final value
≤ 250 ppm/K of final value
≤ 40 µs (typ. 30 µs)
0 °C...55 °C
CE; CSA; cULus; cULusEX; EAC
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
1.2 kVeff / 5 s
III
2
≥ 3 mm
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
1.2 kVeff / 5 s
III
2
≥ 3 mm
Screw connection
2.5/0.5/2.5
112.4/17.5
Screw connection
2.5/0.5/2.5
112.4/17.5
Ordering data
Screw connection
Tension-clamp connection
Type
WAS5 VCC HF 0-10/0-20MA
Qty.
1
Order No.
8447310000
Type
WAS5 VCC HF 0-10/4-20MA
Qty.
1
Order No.
8447340000
Note
Accessories
Note
D.46
Cross-connector for power supplies and markers – refer to Accessories
Cross-connector for power supplies and markers – refer to Accessories
2028820000
WAVESERIES - DC/DC 3-way isolator
20 kHz limiting frequency
0...10 V / 0...10 V
-10 V...+10 V / -10 V...+10 V
U/I
Signal converters
• Signal conversion
• Galvanic isolation between input/output signals and
power supply
• Power supply can be cross-connected using plug-in
jumpers
U/I
VC
D
Technical data
Input
Input voltage / Input current
Input resistance, voltage/current
Output
Output voltage / Output current
Load impedance, voltage/current
Cut-off frequency (-3 dB)
General data
Configuration
Supply voltage
Power consumption
Accuracy
Temperature coefficient
Step response time
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
0...10 V /
500 kΩ /
-10...+10 V /
500 kΩ /
0...10 V /
≥ 2 kΩ /
≥ 15 kHz (typ. 20 kHz)
-10...+10 V /
≥ 2 kΩ /
≥ 15 kHz (typ. 20 kHz)
none
24 V DC ± 25 %
< 1.3 W @ IOUT = 5 mA
± 0.2 % of final value
≤ 250 ppm/K of final value
≤ 40 µs (typ. 30 µs)
0 °C...55 °C
CE; CSA; cULus; EAC
none
24 V DC ± 25 %
< 1.3 W @ IOUT = 5 mA
± 0.2 % of measuring range
≤ 250 ppm/K of measuring range
≤ 40 µs (typ. 30 µs)
0 °C...55 °C
CE; cULus; EAC
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
1.2 kVeff / 5 s
III
2
≥ 3 mm
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
1.2 kVeff / 5 s
III
2
≥ 3 mm
Screw connection
2.5/0.5/2.5
112.4/17.5
Tension clamp connection
1.5/0.5/2.5
112.4/17.5
Screw connection
2.5/0.5/2.5
112.4/17.5
Ordering data
Screw connection
Tension-clamp connection
Type
WAS5 VVC HF 0-10/0-10V
WAZ5 VVC HF 0-10/0-10V
Qty.
1
1
Order No.
8447370000
8447380000
Type
WAS5 VVC HF +-10V/+-10V
Qty.
1
Order No.
8561610000
Note
Accessories
Note
2028820000
Cross-connector for power supplies and markers – refer to Accessories
Cross-connector for power supplies and markers – refer to Accessories
D.47
WAVESERIES - DC/DC 3-way isolator
Signal converters
10 Hz limiting frequency
0(4)...20 mA / 0(4)...20 mA
0...20 mA / 4...20 mA
• Signal conversion
• Galvanic isolation between input/output signals and
power supply
• Power supply can be cross-connected using plug-in
jumpers
U/I
U/I
VC
D
Technical data
Input
Input voltage / Input current
Output
Output voltage / Output current
Load impedance, voltage/current
Cut-off frequency (-3 dB)
General data
Configuration
Supply voltage
Power consumption
Accuracy
Temperature coefficient
Step response time
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
/ 0...20 mA, 4…20mA
/ 0...20 mA
/ 0...20 mA, 4...20 mA
/ ≤ 600 Ω
10 Hz
/ 4...20 mA
/ ≤ 600 Ω
10 Hz
none
24 V DC ± 25 %
< 1.5 W @ IOUT = 20 mA
0.2 %
± 250 ppm/K
≤ 45 ms
0 °C...55 °C
CE; cULus; EAC
none
24 V DC ± 25 %
< 1.5 W @ IOUT = 20 mA
0.2 %
± 250 ppm/K
≤ 45 ms
0 °C...55 °C
CE; cULus; EAC
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
2 kVeff / 5 s
III
2
≥ 3 mm
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
2 kVeff / 5 s
III
2
≥ 3 mm
Screw connection
2.5/0.5/2.5
112.4/17.5
Tension clamp connection
1.5/0.5/2.5
112.4/17.5
Screw connection
2.5/0.5/2.5
112.4/17.5
Ordering data
Screw connection
Tension-clamp connection
Type
WAS5 CCC 0-20/0-20mA
WAZ5 CCC 0-20/0-20mA
Qty.
1
1
Order No.
8540180000
8540190000
Type
WAS5 CCC 0-20/4-20mA
Qty.
1
Order No.
8540250000
Note
Accessories
Note
D.48
Cross-connectors for power supplies and markers: refer to accessories
Cross-connectors for power supplies and markers: refer to accessories
2028820000
WAVESERIES - DC/DC 3-way isolator
10 Hz limiting frequency
0...20 mA / 0...10 V
U/I
Signal converters
• Signal conversion
• Galvanic isolation between input/output signals and
power supply
• Power supply can be cross-connected using plug-in
jumpers
U/I
VC
D
Technical data
Input
Input voltage / Input current
Output
Output voltage / Output current
Load impedance, voltage/current
Cut-off frequency (-3 dB)
General data
Configuration
Supply voltage
Power consumption
Accuracy
Temperature coefficient
Step response time
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
/ 0...20 mA
0...10 V /
≥ 1 kΩ /
10 Hz
none
24 V DC ± 25 %
< 1.3 W @ IOUT = 5 mA
0.2 %
± 250 ppm/K
≤ 45 ms
0 °C...55 °C
CE; cULus; EAC
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
2 kVeff / 5 s
III
2
≥ 3 mm
mm²
mm
Screw connection
2.5/0.5/2.5
112.4/17.5
Ordering data
Screw connection
Tension-clamp connection
Type
WAS5 CVC 0-20mA/0-10V
Qty.
1
Order No.
8540270000
Note
Accessories
Note
2028820000
Cross-connectors for power supplies and markers: refer to accessories
D.49
WAVESERIES - DC/DC 3-way isolator
Signal converters
10 Hz limiting frequency
4...20 mA / 0...20 mA
4...20 mA / 0...10 V
• Signal conversion
• Galvanic isolation between input/output signals and
power supply
• Power supply can be cross-connected using plug-in
jumpers
U/I
U/I
VC
D
Technical data
Input
Input voltage / Input current
Output
Output voltage / Output current
Load impedance, voltage/current
Cut-off frequency (-3 dB)
General data
Configuration
Supply voltage
Power consumption
Current-carrying capacity of cross-connect.
Accuracy
Temperature coefficient
Step response time
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
/ 4...20 mA
/ 4...20 mA
/ 0...20 mA
/ ≤ 600 Ω
10 Hz
0...10 V /
≥ 1 kΩ /
10 Hz
none
24 V DC ± 25 %
< 1.5 W @ IOUT = 20 mA
≤2A
0.2 %
± 250 ppm/K
≤ 45 ms
0 °C...55 °C
CE; cULus; EAC
none
24 V DC ± 25 %
< 1.3 W @ IOUT = 5 mA
≤2A
0.2 %
± 250 ppm/K
≤ 45 ms
0 °C...55 °C
CE; cULus; EAC
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
2 kVeff / 5 s
III
2
≥ 3 mm
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
2 kVeff / 5 s
III
2
≥ 3 mm
Screw connection
2.5 / 0.5 / 2.5
112.4 / 17.5 /
Screw connection
2.5 / 0.5 / 2.5
112.4 / 17.5 /
Ordering data
Screw connection
Type
WAS5 CCC 4-20/0-20MA
Qty.
1
Order No.
8540200000
Type
WAS5 CVC 4-20mA/0-10V
Qty.
1
Order No.
8540230000
Note
Accessories
Note
D.50
Cross-connectors for power supplies and markers: refer to accessories
Cross-connectors for power supplies and markers: refer to accessories
2028820000
WAVESERIES - DC/DC 3-way isolator
10 Hz limiting frequency
0...10 V / 0...20 mA
0...10 V / 4...20 mA
U/I
Signal converters
• Signal conversion
• Galvanic isolation between input/output signals and
power supply
• Power supply can be cross-connected using plug-in
jumpers
U/I
VC
D
Technical data
Input
Input voltage / Input current
Output
Output voltage / Output current
Load impedance, voltage/current
Cut-off frequency (-3 dB)
General data
Configuration
Supply voltage
Power consumption
Accuracy
Temperature coefficient
Step response time
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
0...10 V /
0...10 V /
/ 0...20 mA
/ ≤ 600 Ω
10 Hz
/ 4...20 mA
/ ≤ 600 Ω
10 Hz
none
24 V DC ± 25 %
< 1.5 W @ IOUT = 20 mA
0.2 %
± 250 ppm/K
≤ 45 ms
0 °C...55 °C
CE; cULus; EAC
none
24 V DC ± 25 %
< 1.5 W @ IOUT = 20 mA
0.2 %
± 250 ppm/K
≤ 45 ms
0 °C...55 °C
CE; cULus; EAC
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
2 kVeff / 5 s
III
2
≥ 3 mm
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
2 kVeff / 5 s
III
2
≥ 3 mm
Screw connection
2.5/0.5/2.5
112.4/17.5
Tension clamp connection
1.5/0.5/2.5
112.4/17.5
Screw connection
2.5/0.5/2.5
112.4/17.5
Tension clamp connection
1.5/0.5/2.5
112.4/17.5
Ordering data
Screw connection
Tension-clamp connection
Type
WAS5 VCC 0-10V/0-20MA
WAZ5 VCC 0-10V/0-20MA
Qty.
1
1
Order No.
8540310000
8540320000
Type
WAS5 VCC 0-10V/4-20MA
WAZ5 VCC 0-10V/4-20MA
Qty.
1
1
Order No.
8540290000
8540300000
Note
Accessories
Note
2028820000
Cross-connectors for power supplies and markers: refer to accessories
Cross-connectors for power supplies and markers: refer to accessories
D.51
WAVESERIES - DC/DC 3-way isolator
Signal converters
10 Hz limiting frequency
0...10 V / 0...10 V
• Signal conversion
• Galvanic isolation between input/output signals and
power supply
• Power supply can be cross-connected using plug-in
jumpers
U/I
U/I
VC
D
Technical data
Input
Input voltage / Input current
Output
Output voltage / Output current
Load impedance, voltage/current
Cut-off frequency (-3 dB)
General data
Configuration
Supply voltage
Power consumption
Current-carrying capacity of cross-connect.
Accuracy
Temperature coefficient
Step response time
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage input or output/supply
Overvoltage category
Pollution degree
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
0...10 V /
0...10 V /
≥ 1 kΩ /
10 Hz
none
24 V DC ± 25 %
< 1.3 W @ IOUT = 5 mA
≤2A
0.2 %
± 250 ppm/K
≤ 45 ms
0 °C...55 °C
CE; cULus; EAC
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
2 kVeff / 5 s
III
2
≥ 3 mm
mm²
mm
Screw connection
2.5/0.5/2.5
112.4/17.5
Tension clamp connection
1.5/0.5/2.5
112.4/17.5
Ordering data
Screw connection
Tension-clamp connection
Type
WAS5 VVC 0-10V/0-10V
WAZ5 VVC 0-10V/0-10V
Qty.
1
1
Order No.
8540330000
8540340000
Note
Accessories
Note
D.52
Cross-connectors for power supplies and markers: refer to accessories
2028820000
D
2028820000
D.53
Signal converters
WAVESERIES - DC/DC 2-way isolator
Signal converters
Output-side
supply
4...20 mA / 4...20 mA
• Signal conversion
• Galvanic isolation between input and output signals
• Power supply can be cross-connected using plug-in
jumpers
4...20 mA / 0...20 mA
UL Class I, Div. 2
I
U/I
VC
D
Technical data
Input
Input voltage / Input current
Output
Output voltage / Output current
Load impedance, voltage/current
Cut-off frequency (-3 dB)
General data
Configuration
Supply voltage
Current consumption
Current-carrying capacity of cross-connect.
Accuracy
Temperature coefficient
Step response time
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
/ 4...20 mA
/ 4...20 mA
/ 4...20 mA
/ ≤ 500 Ω
≥ 15 Hz (typ. 20 Hz)
/ 0...20 mA
/ ≤ 500 Ω
≥ 15 Hz (typ. 20 Hz)
none
24 V DC ± 20 %
< 32 mA @ IOUT = 20 mA
≤2A
± 0.2 % of final value
≤ 250 ppm/K of final value
≤ 30 ms (typ. 20 ms)
0 °C...55 °C
CE; CSA; cULus; cULusEX; EAC
none
24 V DC ± 20 %
< 32 mA @ IOUT = 20 mA
≤2A
± 0.2 % of final value
≤ 250 ppm/K of final value
≤ 30 ms (typ. 20 ms)
0 °C...55 °C
CE; CSA; cULus; EAC
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
1.2 kVeff / 5 s
III
2
≥ 3 mm
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
1.2 kVeff / 5 s
III
2
≥ 3 mm
Screw connection
2.5/0.5/2.5
112.4/12.5
Tension clamp connection
1.5/0.5/2.5
112.4/12.5
Screw connection
2.5/0.5/2.5
112.4/12.5
Ordering data
Screw connection
Tension-clamp connection
Type
WAS4 CCC DC 4-20/4-20MA
WAZ4 CCC DC 4-20/4-20MA
Qty.
1
1
Order No.
8444980000
8444990000
Type
WAS4 CCC DC 4-20/0-20MA
Qty.
1
Order No.
8445010000
Note
Accessories
Note
D.54
Cross-connector for power supplies and markers – refer to Accessories
Cross-connector for power supplies and markers – refer to Accessories
2028820000
WAVESERIES - DC/DC 2-way isolator
Output-side
supply
4...20 mA / 0...10 V
UL Class I, Div. 2
Signal converters
• Signal conversion
• Galvanic isolation between input and output signals
• Power supply can be cross-connected using plug-in
jumpers
I
U/I
VC
D
Technical data
Input
Input voltage / Input current
Output
Output voltage / Output current
Load impedance, voltage/current
Cut-off frequency (-3 dB)
General data
Configuration
Supply voltage
Current consumption
Current-carrying capacity of cross-connect.
Accuracy
Temperature coefficient
Step response time
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
/ 4...20 mA
0...10 V /
≥ 1 kΩ /
≥ 15 Hz (typ. 20 Hz)
none
24 V DC ± 20 %
< 20 mA @ IOUT = 10 mA
≤2A
± 0.2 % of final value
≤ 250 ppm/K of final value
≤ 30 ms (typ. 20 ms)
0 °C...55 °C
CE; CSA; cULus; cULusEX; EAC
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
1.2 kVeff / 5 s
III
2
≥ 3 mm
mm²
mm
Screw connection
2.5/0.5/2.5
112.4/12.5
Tension clamp connection
1.5/0.5/2.5
112.4/12.5
Ordering data
Screw connection
Tension-clamp connection
Type
WAS4 CVC DC 4-20/0-10V
WAZ4 CVC DC 4-20/0-10V
Qty.
1
1
Order No.
8445040000
8445050000
Note
Accessories
Note
2028820000
Cross-connector for power supplies and markers – refer to Accessories
D.55
WAVESERIES - DC/DC passive isolator
Signal converters
Signal distributor
Supplied by current loop
2OLP
• Galvanic isolation
• Input and output current loop feed
• Very low power consumption
• No calibration necessary
I
I
I
D
Technical data
Input
Input current
Voltage drop
Output
Output current
Output signal limit
Load impedance, voltage/current
Cut-off frequency (-3 dB)
General data
Configuration
Supply voltage
Accuracy
Temperature coefficient
Step response time
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage input or output/supply
Overvoltage category
Pollution degree
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
([DPSOHRIDSSOLFDWLRQ
4...20 mA (current loop)
3.8 V
a
9$&
6HQVRU
2 x 4...20 mA (current loop)
Approx. 31 mA
/ RL = (UB-12 V) / 20 mA z.B. 600 Ω at 24 V
30 Hz
9$&
P$
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
4 kVeff / 5 s
III
2
≥ 5.5 mm
Screw connection
2.5/0.5/2.5
112.4/17.5
a
P$
none
min. 12 V DC/ max. 30 V DC
typ. 0.1 %; max. 0.2 %
≤ 150 ppm/K
< 20 ms
0 °C...55 °C
CE; cULus; EAC
mm²
mm
9'&
9'&
9$&
a
:$9( $1$/2*8(
2/3
636
9'&
Tension clamp connection
1.5/0.5/2.5
112.4/17.5
Ordering data
Screw connection
Tension-clamp connection
Type
WAS5 CCC 2OLP
WAZ5 CCC 2OLP
Qty.
1
1
Order No.
8581160000
8581170000
Note
Accessories
Note
D.56
Markers – refer to Accessories.
2028820000
WAVESERIES - DC/DC passive isolator
Signal distributor
Supplied by current loop
2OLP
I
Signal converters
• Galvanic isolation
• Input and output current loop feed
• Very low power consumption
• No calibration necessary
• ATEX II 3 G Ex nA IIC T4
• UL Class I, Div. 2
I
I
Technical data
Input
Input current
Voltage drop
Output
Output current
Output signal limit
Load impedance, voltage/current
Cut-off frequency (-3 dB)
General data
Configuration
Supply voltage
Accuracy
Temperature coefficient
Step response time
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage input or output/supply
Overvoltage category
Pollution degree
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
4...20 mA (current loop)
3.8 V
a
9$&
6HQVRU
2 x 4...20 mA (current loop)
Approx. 31 mA
/ RL = (UB-12 V) / 20 mA z.B. 600 Ω at 24 V
30 Hz
9'&
9'&
9$&
a
P$
none
min. 12 V DC/ max. 30 V DC
typ. 0.1 %; max. 0.2 %
≤ 150 ppm/K
< 20 ms
0 °C...55 °C
CE; cULusEX; DEMKOATEX; EAC
P$
DIN EN 60079, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
4 kVeff / 5 s
III
2
≥ 5.5 mm
mm²
mm
D
([DPSOHRIDSSOLFDWLRQ
9$&
a
:$9( $1$/2*8(
2/3
636
9'&
Screw connection
2.5/0.5/2.5
112.4/17.5
Ordering data
Screw connection
Tension-clamp connection
Type
WAS5 CCC 2OLP EX
Qty.
1
Order No.
8975640000
Note
Accessories
Note
2028820000
Markers – refer to Accessories.
D.57
WAVESERIES - DC/DC passive isolator
Signal converters
Output-current loop-powered
OLP
• Galvanic isolation
• Very low power consumption
• Input range selected via DIP switch
• No calibration necessary
U/I
I
D
Technical data
6HWWLQJRSWLRQVVZLWFKSRVLWLRQ
Input
Input voltage
Input resistance, voltage/current
Input current
Rated current
Output
Output current
Output signal limit
Load impedance, voltage/current
Cut-off frequency (-3 dB)
General data
Configuration
Supply voltage
0...5 V: 210 kΩ; 0...10 V: 430 kΩ / 51 Ω
0...20 mA, 4…20mA
40 mA
,QSXW
«P$
«P$
«9
«9
7UDQVPLVVLRQIUHTXHQF\
+]
+]
4...20 mA (current loop)
Approx. 31 mA
/ RL = (UB-12 V) / 20 mA z.B. 600 Ω at 24 V
10 Hz/ 100 Hz switchable
DIP switch
min. 12 V DC/ max. 30 V DC, Loop powered, via 4...20 mA input
Q
Q
ୄ
Screw connection
2.5/0.5/2.5
112.4/17.5
Q
Q
Q
Q
Q
Q
ୄ
Q
ୄ
Q
Q
Q
Q
ୄ
Q
Q
Q
Q
Q
Q
RQ
RII
9$&
a
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
4 kVeff / 5 s
III
2
≥ 5.5 mm
mm²
mm
6:
ୄ
ୄ
9'&
9'&
9$&
:$9( $1$/2*8(
2/3
6HQVRU
Tension clamp connection
1.5/0.5/2.5
112.4/17.5
a
P$
9
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
([DPSOHRIDSSOLFDWLRQ
0 °C...55 °C
0...20mA, 10 Hz
0.2% of measuring range final value
≤ 150 ppm/K
< 10 Hz: 80 ms; 100 Hz: 50 ms
CE; cULus; EAC
Ambient temperature
Default setting
Accuracy
Temperature coefficient
Step response time
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
ୄ
5/
636
Ordering data
Screw connection
Tension-clamp connection
Type
WAS5 OLP
WAZ5 OLP
Qty.
1
1
Order No.
8543720000
8543730000
Note
Accessories
Note
D.58
Markers – refer to Accessories.
2028820000
WAVESERIES - DC/DC passive isolator
CCC LP
CCC LP
• Safe separation
• Very low power consumption
• UL Class I, Div. 2
(1-channel)
(2-channel)
Signal converters
Input current loop feed
I
I
D
Technical data
Input
Input voltage / Input current
Pick-up current
Voltage drop
Output
Output voltage / Output current
Load impedance, voltage/current
General data
Configuration
Ambient temperature
Accuracy
Temperature coefficient
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
/ 0...20 mA current loop
< 100 µA
Approx. 3 V at RL = 0 Ω; approx. 13 V at RL = 500 Ω; (IIN =20 mA)
/ 0...20 mA current loop
< 100 µA
Approx. 3 V at RL = 0 Ω; approx. 13 V at RL = 500 Ω; (IIN =20 mA)
/ 0...20 mA, 4...20 mA
/ ≤ 500 Ω
/ 0...20 mA, 4...20 mA
/ ≤ 500 Ω
none
-25 °C...70 °C
< 0.1 % of end value
≤ 50 ppm/K of final value
CE; CSA; cULus; cULusEX; EAC; GL
none
-25 °C...70 °C
< 0.1 % of end value
≤ 50 ppm/K of final value
CE; CSA; cULus; cULusEX; EAC; GL
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
6 kV
4 kVeff / 1 s
III
2
≥ 5.5 mm
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
6 kV
4 kVeff / 1 s
III
2
≥ 5.5 mm
Screw connection
2.5/0.5/2.5
112.4/17.5
Tension clamp connection
1.5/0.5/2.5
112.4/17.5
Screw connection
2.5/0.5/2.5
112.4/17.5
Tension clamp connection
1.5/0.5/2.5
112.4/17.5
Ordering data
Screw connection
Tension-clamp connection
Type
WAS5 CCC LP 0-20/0-20mA
WAZ5 CCC LP 0-20/0-20mA
Qty.
1
1
Order No.
8444950000
8444960000
Type
WAS5 CCC LP 0-20/0-20mA
WAZ5 CCC LP 0-20/0-20mA
Qty.
1
1
Order No.
8463580000
8463590000
Note
Accessories
Note
2028820000
Markers – refer to Accessories.
Markers – refer to Accessories.
D.59
Signal converters
WAVESERIES - Temperature measuring transducer
RTD signal isolator/converter
PRO RTD
• Universally adjustable via DIP switch
• 3-way isolation
• Linearisation
• Power supply can be cross-connected using plug-in
jumpers
• WAVETOOL software helps with configuration,
download at www.weidmueller.com
UL Class I, Div. 2
RTD
J,R
U/I
VC
D
Technical data
Input
Sensor
PT100/2-/3-/4-wire, Ni100/2-/3-/4-wire, potentiometer: min. 100 Ω,
max. 100 kΩ, resistance: 0-450 Ω
Configurable, PT100: -200°C…850°C, NI100: -60°C…+250°C
Temperature input range
Output
Output current / Output voltage
Offset current / Offset voltage
Load impedance, voltage/current
Sensor error detection
Fine adjustment
Status indicator
0...20 mA, 4...20 mA / 0...10 V
max. 100 µA / max. 0.05 V
≥ 1 kΩ / ≤ 600 Ω
LED flashing (output value: > 20 mA, >10 V)
≥ ± 5 %, Version 1 and later: ≥ 12.5 % / potentiometer: 12.5%...25%
Module active: LED on/ wire breakage: LED flashing/
Error: LED off
General data
Configuration
Supply voltage
Power consumption
Step response time
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
DIP switch, Potentiometer
830...880...980mW at IOUT = 20 mA
fast/slow: 2-/3-/4-conductor: 1.2 s/2.2 s; potentiometer: 0.5 s/1.1 s
0 °C...55 °C
CE; cULus; cULusEX; EAC; GL
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
2 kVeff / 5 s
III
2
≥ 3 mm
mm²
mm
Screw connection
2.5/0.5/2.5
112.4/17.5
Tension clamp connection
1.5/0.5/2.5
112.4/17.5
Ordering data
Screw connection
Tension-clamp connection
Type
WAS5 PRO RTD
WAZ5 PRO RTD
Qty.
1
1
Order No.
8560700000
8560710000
Note
Accessories
Note
D.60
Cross-connector for power supplies and markers – refer to Accessories
2028820000
WAVESERIES - Temperature measuring transducer
PRO RTD
■ = on
□ = off
Choice of inputs
Switch 1
Input
1
2
3
PT100 2-wire
■ ■ ■
PT100 3-wire
□ ■ ■
PT100 4-wire
■ □ ■
R
2-wire
□ □ ■
NI100 2-wire
■ ■ □
NI100 3-wire
□ ■ □
NI100 4-wire
■ □ □
Potentiometer
□ □ □
Choice of outputs
Switch 2
Output
6
7
0...10 V
■
□
0...5 V
■
■
0...20 mA
□
□
4...20 mA
□
■
Choice of step
response time
Step response time
slow
fast
ϑmin
0 °C
-10 °C
-20 °C
-25 °C
-30 °C
-40 °C
-50 °C
-60 °C
-70 °C
-80 °C
-90 °C
-100 °C
-150 °C
-200 °C
Choice of minimum input size
Switch 1
Rmin
Potimin
4
5
6
0Ω
0%
■
■
■
10 Ω
10 %
■
■
■
20 Ω
20 %
■
■
□
20 Ω
25 %
■
■
□
30 Ω
30 %
■
□
■
40 Ω
40 %
■
□
■
50 Ω
50 %
■
□
□
60 Ω
60 %
■
□
□
70 Ω
70 %
□
■
■
80 Ω
80 %
□
■
■
90 Ω
□
■
□
100 Ω
□
■
□
150 Ω
□
□
■
200 Ω
□
□
■
□
Special area
Choice of measuring range
T
40 K
50 K
60 K
70 K
80 K
90 K
100 K
110 K
120 K
125 K
130 K
140 K
150 K
160 K
170 K
180 K
190 K
200 K
250 K
300 K
350 K
400 K
450 K
500 K
550 K
600 K
650 K
700 K
750 K
800 K
850 K
900 K
2028820000
R
20 Ω
25 Ω
30 Ω
35 Ω
40 Ω
45 Ω
50 Ω
55 Ω
60 Ω
62.5 Ω
65 Ω
70 Ω
75 Ω
80 Ω
85 Ω
90 Ω
95 Ω
100 Ω
125 Ω
150 Ω
175 Ω
200 Ω
225 Ω
250 Ω
275 Ω
300 Ω
325 Ω
350 Ω
375 Ω
400 Ω
425 Ω
450 Ω
Poti
20 %
25 %
30 %
35 %
40 %
45 %
50 %
55 %
60 %
62.5 %
65 %
70 %
75 %
80 %
85 %
90 %
95 %
100 %
-----------------------------
1
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
Switch 2
2
3
4
■ ■ ■
■ ■ ■
■ ■ □
■ ■ □
■ □ ■
■ □ ■
■ □ □
■ □ □
□ ■ ■
□ ■ ■
□ ■ □
□ ■ □
□ □ ■
□ □ ■
□ □ □
□ □ □
■ ■ ■
■ ■ ■
■ ■ □
■ ■ □
■ □ ■
■ □ ■
■ □ □
■ □ □
□ ■ ■
□ ■ ■
□ ■ □
□ ■ □
□ □ ■
□ □ ■
□ □ □
□ □ □
Switch on the manual fine
adjustments
S. 1
Man. adjustment
8
off
□
on
■
Signal converters
Switch position / setting options
S. 2
8
■
□
Accuracy, slow/fast step response time
7
■
□
■
□
■
□
■
□
■
□
■
□
■
□
PT 100,Ni 100: 0.3 % from measuring range 0.8 %
from measuring range < 100 K / 0.3 K / 0.8 K
Potentiometer: 0.2 % from end value / 0.3 %
Resistance: 0.2 % from end value / 0.3 %
D
Temperature coefficient
Measuring range ≥ 200 K
100 K ≤ Measuring range < 200 K
40 K ≤ Measuring range < 100 K
≤ 200 ppm / °C
≤ 250 ppm / °C
≤ 400 ppm / °C
■
Adjustment example for zero and span
5
■
□
■
□
■
□
■
□
■
□
■
□
■
□
■
□
■
□
■
□
■
□
■
□
■
□
■
□
■
□
■
□
Temperature adjustment:
Output
DIP switch
Span
4…20 mA
-10 °C…+110 °C
75…110 °C
Range
Adjustment range
120 °C
± 12.5 %
Zero
–25 °C
–10 °C
95 °C
110 °C
125 °C
–5 °C
Span
5 °C
110 °C
125 °C
140 °C
Wavetool adjustment tool
This service tool enables quick and straightforward configuration of the WAVEANALOG PRO.
Internet download:
http://www.weidmueller.com
D.61
WAVESERIES - Temperature measuring transducer
Signal converters
RTD signal isolator/converter
PRO RTD 1000
• Universally adjustable via DIP switch
• 3-way isolation
• Linearisation
• Power supply can be cross-connected using plug-in
jumpers
RTD
J,R
U/I
VC
D
Technical data
Input
Sensor
Ni1000/2-/3-/4-wire, Potentiometer: min. 0-1kΩ, max. 0-100kΩ,
PT1000/2-/3-/4-wire, Resistance: 0-4.5kΩ
Configurable, PT1000: -200°C…850°C, NI1000: -60°C…+250°C
Temperature input range
Output
Output current / Output voltage
Offset current / Offset voltage
Load impedance, voltage/current
Sensor error detection
Fine adjustment
Status indicator
0...20 mA, 4...20 mA / 0...10 V
max. 100 µA / max. 0.05 V
≥ 1 kΩ / ≤ 600 Ω
LED flashing (output value: > 20 mA, >10 V)
± 12.5 % of FSR; potentiometer: ± 12.5 % ... ± 25 %
Module active: LED on/ wire breakage: LED flashing/
Error: LED off
General data
Configuration
Supply voltage
Power consumption
Step response time
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
DIP switch, Potentiometer
24 V DC ± 20 %
830...880...980mW at IOUT = 20 mA
Fast/slow:2-/3-/4-conductor: 1.2s/2.3s; potentiometer: 0.5s/1.2s
0 °C...55 °C
CE; cULus; EAC; GL
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
2 kVeff / 5 s
III
2
≥ 3 mm
Screw connection
2.5 / 0.5 / 2.5
112.4 / 17.5 /
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
Ordering data
Screw connection
Type
WAS5 PRO RTD 1000
Qty.
1
Order No.
8679490000
Note
Accessories
Note
D.62
Cross-connector for power supplies and markers – refer to Accessories
2028820000
WAVESERIES - Temperature measuring transducer
PRO RTD 1000
■ = on
□ = off
Choice of inputs
Switch 1
Input
1
2
3
PT1000 2-wire
■ ■ ■
PT1000 3-wire
□ ■ ■
PT1000 4-wire
■ □ ■
R
2-wire
□ □ ■
NI1000 2-wire
■ ■ □
NI1000 3-wire
□ ■ □
NI1000 4-wire
■ □ □
Potentiometer
□ □ □
Choice of outputs
Switch 2
Output
6
7
0...10 V
■
□
0...5 V
■
■
0...20 mA
□
□
4...20 mA
□
■
Choice of step
response time
Step response time
slow
fast
ϑmin
0 °C
-10 °C
-20 °C
-25 °C
-30 °C
-40 °C
-50 °C
-60 °C
-70 °C
-80 °C
-90 °C
-100 °C
-150 °C
-200 °C
Choice of minimum input size
Switch 1
Rmin
Potimin
4
5
6
0Ω
0%
■
■
■
100 Ω
10 %
■
■
■
200 Ω
20 %
■
■
□
200 Ω
25 %
■
■
□
300 Ω
30 %
■
□
■
400 Ω
40 %
■
□
■
500 Ω
50 %
■
□
□
600 Ω
60 %
■
□
□
700 Ω
70 %
□
■
■
800 Ω
80 %
□
■
■
900 Ω
□
■
□
1000 Ω
□
■
□
1500 Ω
□
□
■
2000 Ω
□
□
■
□
Special area
Choice of measuring range
T
40 K
50 K
60 K
70 K
80 K
90 K
100 K
110 K
120 K
125 K
130 K
140 K
150 K
160 K
170 K
180 K
190 K
200 K
250 K
300 K
350 K
400 K
450 K
500 K
550 K
600 K
650 K
700 K
750 K
800 K
850 K
900 K
2028820000
R
200 Ω
250 Ω
300 Ω
350 Ω
400 Ω
450 Ω
500 Ω
550 Ω
600 Ω
625 Ω
650 Ω
700 Ω
750 Ω
800 Ω
850 Ω
900 Ω
950 Ω
1000 Ω
1250 Ω
1500 Ω
1750 Ω
2000 Ω
2250 Ω
2500 Ω
2750 Ω
3000 Ω
3250 Ω
3500 Ω
3750 Ω
4000 Ω
4250 Ω
4500 Ω
Poti
20 %
25 %
30 %
35 %
40 %
45 %
50 %
55 %
60 %
62.50 %
65 %
70 %
75 %
80 %
85 %
90 %
95 %
100 %
-----------------------------
1
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
□
Switch 2
2
3
4
■ ■ ■
■ ■ ■
■ ■ □
■ ■ □
■ □ ■
■ □ ■
■ □ □
■ □ □
□ ■ ■
□ ■ ■
□ ■ □
□ ■ □
□ □ ■
□ □ ■
□ □ □
□ □ □
■ ■ ■
■ ■ ■
■ ■ □
■ ■ □
■ □ ■
■ □ ■
■ □ □
■ □ □
□ ■ ■
□ ■ ■
□ ■ □
□ ■ □
□ □ ■
□ □ ■
□ □ □
□ □ □
Switch on the manual fine
adjustments
S. 1
Man. adjustment
8
off
□
on
■
Signal converters
Switch position / setting options
S. 2
8
■
□
Accuracy, slow/fast step response time
7
■
□
■
□
■
□
■
□
■
□
■
□
■
□
PT 100,Ni 100: 0.3 % from measuring range 0.8 %
from measuring range < 100 K / 0.3 K / 0.8 K
Potentiometer: 0.2 % from end value / 0.3 %
Resistance: 0.2 % from end value / 0.3 %
D
Temperature coefficient
Measuring range ≥ 200 K
100 K ≤ Measuring range < 200 K
40 K ≤ Measuring range < 100 K
≤ 200 ppm / °C
≤ 250 ppm / °C
≤ 400 ppm / °C
■
Adjustment example for zero and span
5
■
□
■
□
■
□
■
□
■
□
■
□
■
□
■
□
■
□
■
□
■
□
■
□
■
□
■
□
■
□
■
□
Temperature adjustment:
Output
DIP switch
Span
4…20 mA
-10 °C…+110 °C
75…110 °C
Range
Adjustment range
120 °C
± 12.5 %
Zero
–25 °C
–10 °C
95 °C
110 °C
125 °C
–5 °C
Span
5 °C
110 °C
125 °C
140 °C
Wavetool adjustment tool
This service tool enables quick and straightforward
configuration of the WAVEANALOG PRO.
Internet download:
http://www.weidmueller.com
D.63
Signal converters
WAVESERIES - Temperature measuring transducer
RTD signal isolator/converter
PRO RTD Cu
• Universally adjustable via DIP switch
• 3-way isolation
• Linearisation
• Power supply can be cross-connected using plug-in
jumpers.
UL Class I, Div.2
Cu
Selection of connection
Switch 1
Connection
1
◼
3-wire
◼
4-wire
ϑ min
– 0 °C
– 10 °C
– 20 °C
– 25 °C
– 30 °C
– 40 °C
– 50 °C
– 60 °C
– 70 °C
– 80 °C
– 90 °C
– 100 °C
– 150 °C
– 200 °C
U/I
VC
D
Technical data
Input
Sensor
Temperature input range
Output
Output current / Output voltage
Offset current / Offset voltage
Load impedance, voltage/current
Sensor error detection
Fine adjustment
Status indicator
3-/4-wired, Cu 10. Cu 25, Cu 50. Cu 100
Adjustable from -200...+260°C
General data
Configuration
Supply voltage
Power consumption
Step response time
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
Span
40 K
50 K
60 K
70 K
80 K
90 K
100 K
110 K
120 K
125 K
130 K
140 K
150 K
160 K
170 K
180 K
190 K
200 K
210 K
220 K
230 K
240 K
250 K
260 K
270 K
280 K
290 K
300 K
350 K
400 K
450 K
460 K
DIP switch
24 V DC ± 20 %
880...980...1030mW at IOUT = 20 mA
Fast: 1.2 s/ slow: 2.2 s
0 °C...55 °C
CE; cULus; cULusEX; EAC
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300 V
4 kV
2 kVeff / 5 s
III
2
≥ 3 mm
Screw connection
2.5 / 0.5 / 2.5
112.4 / 17.5 /
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
Ordering data
Screw connection
Type
WAS5 PRO RTD Cu
Qty.
1
Order No.
8638950000
◼
◼
◼
◼
◼
◼
◼
◼
Selection of minimum input values
Switch 1
4
5
6
◼
special range
0...20 mA, 4...20 mA / 0...10 V
max. 100 µA / max. 0.05 V
≥ 1 kΩ / ≤ 600 Ω
LED flashing (output value: > 20 mA, >10 V)
± 12.5% of FSR
Module active: LED on/ wire breakage: LED flashing/
Error: LED off
Type
Cu 10
Cu 25
Cu 50
Cu 100
Selection of senor
Switch 1
2
3
◼
7
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
Selection of the measurement range
Switch 2
1
2
3
4
5
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
Selection of Output
Switch 2
Connection 6
7
◼
◼
0 ... 10 V
◼
0 ... 20 mA ◼
◼
4 ... 20 mA ◼
Switching on the
manual fine adjustment
Switch 1
man adj.
8
◼
off
◼
on
Selection of step set time
Note
Time of step
response
slow
fast
Accessories
Note
D.64
Cross-connector for power supplies and markers – refer to Accessories
Switch 2
8
◼
◼
◼
◼
= on
= off
2028820000
WAVESERIES - Temperature measuring transducers
RTD, 4-wire converter
PT100 / 4 0 (4)...20 mA
PT100 / 4 0...10 V
Signal converters
• 4-wire connection
• Adjustable temperature range from -200 °C...+800 °C
• Power supply can be cross-connected using plug-in
jumpers
• No galvanic isolation between input and output circuits
PT100
J
U/I
VC
D
Technical data
Input
Sensor
Sensor supply
Output
Output voltage / Output current
Load impedance, voltage/current
General data
Configuration
Supply voltage / Current consumption
Ambient temperature
Accuracy
Approvals
Standards
EMC standards
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
PT100 / 2-/3-/4-wire
1.45 mA
PT100 / 2-/3-/4-wire
1.45 mA
/ 0...20 mA, 4...20 mA
/ ≤ 500 Ω
0...10 V /
≥ 1 kΩ /
DIP switch, Potentiometer
24 V DC ± 20 % /
0 °C...55 °C
100K ≤ MB < 600K: 0.1 %; MB ≥ 600K: 0.2 %; of measuring range
CE; CSA; cULus; EAC
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
DIP switch, Potentiometer
24 V DC ± 20 % /
0 °C...55 °C
100K ≤ MB < 600K: 0.1 %; MB ≥ 600K: 0.2 %; of measuring range
CE; CSA; cULus; EAC
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
Tension clamp connection
1.5/0.5/2.5
112.4/12.5
Tension clamp connection
1.5/0.5/2.5
112.4/12.5
Tension clamp connection
1.5/0.5/2.5
112.4/12.5
Tension clamp connection
1.5/0.5/2.5
112.4/12.5
Ordering data
Adjustable from -200...+800°C
Tension-clamp connection
Note
Type
WTZ4 PT100/4 C 0/4-20mA
Qty.
1
Order No.
8432280000
Type
WTZ4 PT100/4 V 0-10V
Cross-connectors for power supplies and
markers - refer to WAVESERIES accessories
Qty.
1
Order No.
8432250000
Specify temperature range for special calibrations.
Applications
Switch position/setting options
Example for Zero and Span
Temperature adjustment
Tmin
Span
-10 °C
75…110 °C
Span
Adjustment of Span
95 °C
+25 %
Temperature coefficient
≤ 200 ppm/°C (typ. 80 ppm/°C)
Measurement range ≥ 200 K
100 K ≤ Measurement range < 200 K ≤ 205 ppm/°C (typ. 90 ppm/°C)
40 K ≤ Measurement range < 100 K ≤ 450 ppm/°C (typ. 180 ppm/°C)
Zero
-10 °C
-13,75 °C
Span
-10 °C
2028820000
85 °C
118,75 °C
65 °C
85 °C
100 °C
Aids
• Voltage supply 24 V DC, 50 mA
• Simulator for PT 100 or precision-resistance-decade
• Ampere-/voltmeter which can be calibrated to an accuracy of
> 0,1% of the end value.
Tmin
0 °C
-10 °C
-20 °C
-40 °C
-60 °C
-80 °C
-100 °C
-200 °C
1
2
3
Output 1)
Range
7
0…20 mA
4…20 mA
1)
only modules with current output
Span
40…50 °C
50…75 °C
75…110 °C
110…165 °C
165…245 °C
245…360 °C
360…540 °C
540…800 °C
4 5 6
PT 100
8 9 10
2-Wire
3-Wire
4-Wire
= on
= off
D.65
WAVESERIES - Temperature measuring transducers
Signal converters
RTD, 3-wire converter
PT100 / 3 0...10 V
PT100 / 3 0 (4)...20 mA
• 3-wire connection
• Adjustable temperature range from -200 °C...+800 °C
• Power supply can be cross-connected using plug-in
jumpers
• No galvanic isolation between input and output circuits
PT100
J
U/I
VC
D
Technical data
Input
Sensor
Sensor supply
Output
Output voltage / Output current
Load impedance, voltage/current
General data
Configuration
Supply voltage / Current consumption
Ambient temperature
Accuracy
Approvals
Standards
EMC standards
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
PT100/3-wire
1.45 mA
PT100/3-wire
1.45 mA
0...10 V /
≥ 1 kΩ /
/ 0...20 mA, 4...20 mA
/ ≤ 500 Ω
DIP switch, Potentiometer
24 V DC ± 20 % /
0 °C...55 °C
± 0.5 % of measuring range
CE; CSA; cULus; EAC
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
DIP switch, Potentiometer
24 V DC ± 20 % /
0 °C...55 °C
± 0.5 % of measuring range
CE; CSA; cULus; EAC
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
Tension clamp connection
1.5/0.5/2.5
112.4/12.5
Tension clamp connection
1.5/0.5/2.5
112.4/12.5
Tension clamp connection
1.5/0.5/2.5
112.4/12.5
Ordering data
Adjustable from -200...+800°C
Tension-clamp connection
Note
Type
WTZ4 PT100/3 V 0-10V
Qty.
1
Order No.
8432130000
Type
WTZ4 PT100/3 C 0/4-20mA
Specify temperature range for special calibrations.
Qty.
1
Order No.
8432160000
Cross-connectors for power supplies and
markers - refer to WAVESERIES accessories
Applications
Switch position/setting options
Example for Zero and Span
Temperature adjustment
Tmin
Span
-10 °C
75…110 °C
Span
Adjustment of Span
95 °C
+25 %
Temperature coefficient
≤ 200 ppm/°C (typ. 80 ppm/°C)
Measurement range ≥ 200 K
100 K ≤ Measurement range < 200 K ≤ 205 ppm/°C (typ. 90 ppm/°C)
40 K ≤ Measurement range < 100 K ≤ 450 ppm/°C (typ. 180 ppm/°C)
Zero
-10 °C
-13,75 °C
Span
-10 °C
D.66
85 °C
118,75 °C
65 °C
85 °C
100 °C
Aids
• Voltage supply 24 V DC, 50 mA
• Simulator for PT 100 or precision-resistance-decade
• Ampere-/voltmeter which can be calibrated to an accuracy of
> 0,1% of the end value.
Tmin
0 °C
-10 °C
-20 °C
-40 °C
-60 °C
-80 °C
-100 °C
-200 °C
1
2
3
Output 1)
Range
7
0…20 mA
4…20 mA
1)
only modules with current output
Span
40…50 °C
50…75 °C
75…110 °C
110…165 °C
165…245 °C
245…360 °C
360…540 °C
540…800 °C
4 5 6
PT 100
8 9 10
2-Wire
3-Wire
4-Wire
= on
= off
2028820000
WAVESERIES - Temperature measuring transducers
RTD, 2-wire converter
PT100 / 2 0...10 V
PT100/2 0 (4)...20 mA
Signal converters
• 2-wire connection
• Adjustable temperature range from -200 °C...+800 °C
• Power supply can be cross-connected using plug-in
jumpers
• No galvanic isolation between input and output circuits
PT100
J
U/I
VC
D
Technical data
Input
Sensor
Sensor supply
Output
Output voltage / Output current
Load impedance, voltage/current
General data
Configuration
Supply voltage / Current consumption
Ambient temperature
Accuracy
Approvals
Standards
EMC standards
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
PT100/2-wire
1.45 mA
PT100/2-wire
1.45 mA
0...10 V /
≥ 1 kΩ /
/ 0...20 mA, 4...20 mA
/ ≤ 500 Ω
DIP switch, Potentiometer
24 V DC ± 20 % / < 38 mA @ IOUT = 20 mA
0 °C...55 °C
± 0.5 % of measuring range
CE; CSA; cULus; EAC
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
DIP switch, Potentiometer
24 V DC ± 20 % / < 48 mA @ IOUT = 20 mA
0 °C...55 °C
± 0.5 % of measuring range
CE; CSA; cULus; EAC
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
Tension clamp connection
1.5/0.5/2.5
112.4/12.5
Tension clamp connection
1.5/0.5/2.5
112.4/12.5
Tension clamp connection
1.5/0.5/2.5
112.4/12.5
Tension clamp connection
1.5/0.5/2.5
112.4/12.5
Ordering data
Adjustable from -200...+800°C
Tension-clamp connection
Note
Type
WTZ4 PT100/2 V 0-10V
Qty.
1
Order No.
8432190000
Type
WTZ4 PT100/2 C 0/4-20mA
Specify temperature range for special calibrations.
Qty.
1
Order No.
8432220000
Cross-connectors for power supplies and
markers - refer to WAVESERIES accessories
Applications
Switch position/setting options
Example for Zero and Span
Temperature adjustment
Tmin
Span
-10 °C
75…110 °C
Span
Adjustment of Span
95 °C
+25 %
Temperature coefficient
≤ 200 ppm/°C (typ. 80 ppm/°C)
Measurement range ≥ 200 K
100 K ≤ Measurement range < 200 K ≤ 205 ppm/°C (typ. 90 ppm/°C)
40 K ≤ Measurement range < 100 K ≤ 450 ppm/°C (typ. 180 ppm/°C)
Zero
-10 °C
-13,75 °C
Span
-10 °C
2028820000
85 °C
118,75 °C
65 °C
85 °C
100 °C
Aids
• Voltage supply 24 V DC, 50 mA
• Simulator for PT 100 or precision-resistance-decade
• Ampere-/voltmeter which can be calibrated to an accuracy of
> 0,1% of the end value.
Tmin
0 °C
-10 °C
-20 °C
-40 °C
-60 °C
-80 °C
-100 °C
-200 °C
1
2
3
Output 1)
Range
7
0…20 mA
4…20 mA
1)
only modules with current output
Span
40…50 °C
50…75 °C
75…110 °C
110…165 °C
165…245 °C
245…360 °C
360…540 °C
540…800 °C
4 5 6
PT 100
8 9 10
2-Wire
3-Wire
4-Wire
= on
= off
D.67
WAVESERIES - Temperature measuring transducer
Signal converters
Thermal converter type:
K,J,T,E,N,R,S,B
PRO Thermo
• 3-way isolation
• Internal cold-junction compensation
• Power supply can be cross-connected using plug-in
jumpers
• Suitable for insulated and uninsulated thermocouples
• WAVETOOL software helps with configuration,
download at www.weidmueller.com
UL Class I, Div. 2
Typ
K
J
T
E
N
R
S
B
Select of
thermocoupler
SW1
1
2
3
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
U/I
J
VC
D
Technical data
Input
Sensor
Temperature input range
Output
Output voltage / Output current
Load impedance, voltage/current
Offset current / Offset voltage
Line resistance in measuring circuit
Sensor error detection
Fine adjustment
Status indicator
Thermo element (IEC 584) type: K,J,T,E,N,R,S,B
-200...+1820 °C
0...10 V / 0...20 mA, 4...20 mA
≥ 1 kΩ / ≤ 600 Ω
max. 100 µA / max. 0.05 V
50 Ω
LED flashing (output value: > 20 mA, >10 V)
± 5% (switchable)
Module active: LED on/ wire breakage: LED flashing/
Error: LED off
General data
Configuration
Supply voltage
Power consumption
Step response time
Current-carrying capacity of cross-connect.
Ambient temperature
Storage temperature
Default setting
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
DIP switch
24 V DC ± 20 %
800...850...950 mW at IOUT = 20 mA
without filter: max. 1.4 s; with filter: max. 7.5 s
≤2A
0 °C...55 °C
-20 °C...85 °C
Type K; 0...1000°C; 4...20mA; filter: off; man. calibration: off
CE; cULus; cULusEX; EAC; GL
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300
4 kV
2 kVeff / 5 s
III
2
≥ 3 mm
mm²
mm
Screw connection
2.5/0.5/2.5
112.4/17.5
Screw connection
Tension-clamp connection
Type
WAS5 PRO Thermo
WAZ5 PRO Thermo
Tension clamp connection
1.5/0.5/2.5
112.4/17.5
Ordering data
Qty.
1
1
Order No.
8560720000
8560730000
Note
Selection of
temperature span
SW2
Span
1 2 3 4 5
100 °C ◼ ◼ ◼ ◼ ◼
150 °C ◼ ◼ ◼ ◼ ◼
200 °C ◼ ◼ ◼ ◼ ◼
250 °C ◼ ◼ ◼ ◼ ◼
300 °C ◼ ◼ ◼ ◼ ◼
350 °C ◼ ◼ ◼ ◼ ◼
400 °C ◼ ◼ ◼ ◼ ◼
450 °C ◼ ◼ ◼ ◼ ◼
500 °C ◼ ◼ ◼ ◼ ◼
550 °C ◼ ◼ ◼ ◼ ◼
600 °C ◼ ◼ ◼ ◼ ◼
650 °C ◼ ◼ ◼ ◼ ◼
700 °C ◼ ◼ ◼ ◼ ◼
750 °C ◼ ◼ ◼ ◼ ◼
800 °C ◼ ◼ ◼ ◼ ◼
850 °C ◼ ◼ ◼ ◼ ◼
900 °C ◼ ◼ ◼ ◼ ◼
950 °C ◼ ◼ ◼ ◼ ◼
1000 °C ◼ ◼ ◼ ◼ ◼
1050 °C ◼ ◼ ◼ ◼ ◼
1100 °C ◼ ◼ ◼ ◼ ◼
1150 °C ◼ ◼ ◼ ◼ ◼
1200 °C ◼ ◼ ◼ ◼ ◼
1250 °C ◼ ◼ ◼ ◼ ◼
1300 °C ◼ ◼ ◼ ◼ ◼
1350 °C ◼ ◼ ◼ ◼ ◼
1400 °C ◼ ◼ ◼ ◼ ◼
1450 °C ◼ ◼ ◼ ◼ ◼
1500 °C ◼ ◼ ◼ ◼ ◼
1600 °C ◼ ◼ ◼ ◼ ◼
1700 °C ◼ ◼ ◼ ◼ ◼
1800 °C ◼ ◼ ◼ ◼ ◼
Accuracy
K -200 °C … -150 °C
-150 °C …1200 °C
1200 °C …1372 °C
J -200 °C … -150 °C
-150 °C …1200 °C
T -200 °C … -150 °C
-150 °C … 400 °C
E -200 °C … -150 °C
-150 °C …1000 °C
N -200 °C … -150 °C
-150 °C …1300 °C
R -50 °C … 200 °C
200 °C …1760 °C
S -50 °C … 200 °C
200 °C …1760 °C
B 50 °C … 250 °C
250 °C … 500 °C
500 °C …1820 °C
Selection of minimum
temperature
SW1
ϑ min
1 2 3
◼ ◼ ◼
0 °C
◼ ◼ ◼
– 10 °C
◼ ◼ ◼
– 20 °C
◼ ◼ ◼
– 30 °C
◼ ◼ ◼
– 40 °C
◼ ◼ ◼
– 50 °C
◼ ◼ ◼
– 100 °C
◼ ◼ ◼
– 150 °C
◼ ◼ ◼
– 200 °C
◼ ◼ ◼
+ 50 °C
◼ ◼ ◼
+ 100 °C
◼ ◼ ◼
+ 150 °C
◼ ◼ ◼
+ 200 °C
◼ ◼ ◼
+ 250 °C
◼ ◼ ◼
+ 500 °C
Special range ◼ ◼ ◼
4
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
Selection of output
Switch 2
Output
6
7
◼
◼
0 ... 10 V
◼
◼
0 ... 20 mA
◼
◼
4 ... 20 mA
Switching on the
manual fine adjustment
SW 2
man. adjust.
off
on
6
◼
◼
Switching on the
filter function
SW 2
Filter
off
on
◼
◼
8
◼
◼
= on
= off
± (5K + 0.1 % of set range)
± (3K + 0.1 % of set range)
± (4K + 0.1 % of set range)
± (4K + 0.1 % of set range)
± (3K + 0.1 % of set range)
± (5K + 0.1 % of set range)
± (3K + 0.1 % of set range)
± (4K + 0.1 % of set range)
± (3K + 0.1 % of set range)
± (6K + 0.1 % of set range)
± (3K + 0.1 % of set range)
± (10K + 0.1 % of set range)
± (6K + 0.1 % of set range)
± (10K + 0.1 % of set range)
± (6K + 0.1 % of set range)
± (25K + 0.1 % of set range)
± (10K + 0.1 % of set range)
± (6K + 0.1 % of set range)
Accessories
Note
D.68
Cross-connector for power supplies and markers – refer to Accessories
2028820000
WAVESERIES - Temperature measuring transducer
Thermal converter type:
K, J, T, E, N, R, S, B
Thermo Select
Signal converters
• No calibration necessary
• Internal cold-junction compensation
• Output signal selectable
• Power supply can be cross-connected using plug-in
jumpers
• Suitable for insulated thermocouples
• No galvanic isolation between input and output circuits
Switch position/setting options
J
Type
K
J
T
E
N
R
S
B
U/I
VC
Technical data
Input
Sensor
Temperature input range
Output
Output voltage / Output current
Load impedance, voltage/current
Temperature coefficient
Step response time
Sensor error detection
General data
Configuration
Supply voltage
Current consumption
Current-carrying capacity of cross-connect.
Ambient temperature
Storage temperature
Approvals
Insulation coordination
Standards
EMC standards
Tmin
0 °C
– 10 °C
– 20 °C
– 30 °C
– 40 °C
– 50 °C
– 100 °C
– 150 °C
– 200 °C
+ 50 °C
+ 100 °C
+ 150 °C
+ 200 °C
+ 250 °C
+ 500 °C
Thermo element (IEC 584) type: K,J,T,E,N,R,S,B
-200...+1820 °C
0...10 V / 0...20 mA, 4...20 mA
/ ≤ 500 Ω
± (200 ppm from the span + 0.075 K)/K
without filter: 1.1 s; with filter: 6 s
LED flashing (output value: > 20 mA, >10 V)
DIP switch
24 V DC ± 20 %
< 38 mA @ IOUT = 20 mA
≤2A
0 °C...55 °C
-20 °C...85 °C
CE; CSA; cULus; EAC
Output
0 ... 10 V
0 ... 20 mA
4 ... 20 mA
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
Filter
off
on
SW 1
1
2
3
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
SW 1
4 5
6
7
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
SW 2
6
7
◼
◼
◼
◼
◼
◼
Span
100 °C
150 °C
200 °C
250 °C
300 °C
350 °C
400 °C
450 °C
500 °C
550 °C
600 °C
650 °C
700 °C
750 °C
800 °C
850 °C
900 °C
950 °C
1000 °C
1050 °C
1100 °C
1150 °C
1200 °C
1250 °C
1300 °C
1350 °C
1400 °C
1450 °C
1500 °C
1600 °C
1700 °C
1800 °C
Screw connection
2.5/0.5/2.5
112.4/12.5
Tension clamp connection
1.5/0.5/2.5
112.4/12.5
Ordering data
Screw connection
Tension-clamp connection
Type
WTS4 THERMO
WTZ4 THERMO
Qty.
1
1
Order No.
8432300000
8432310000
Note
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
D
8
◼
◼
mm²
mm
◼
◼
◼
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
SW 2
1 2 3 4 5
Accuracy
K -200 °C … -150 °C
-150 °C …1200 °C
1200 °C …1372 °C
J -200 °C … -150 °C
-150 °C …1200 °C
T -200 °C … -150 °C
-150 °C … 400 °C
E -200 °C … -150 °C
-150 °C …1000 °C
N -200 °C … -150 °C
-150 °C …1300 °C
R -50 °C … 200 °C
200 °C …1760 °C
S -50 °C … 200 °C
200 °C …1760 °C
B 50 °C … 250 °C
250 °C … 500 °C
500 °C …1820 °C
= off
= on
± (5K + 0,1 % of set range)
± (3K + 0,1 % of set range)
± (4K + 0,1 % of set range)
± (4K + 0,1 % of set range)
± (3K + 0,1 % of set range)
± (5K + 0,1 % of set range)
± (3K + 0,1 % of set range)
± (4K + 0,1 % of set range)
± (3K + 0,1 % of set range)
± (6K + 0,1 % of set range)
± (3K + 0,1 % of set range)
± (10K + 0,1 % of set range)
± (6K + 0,1 % of set range)
± (10K + 0,1 % of set range)
± (6K + 0,1 % of set range)
± (25K + 0,1 % of set range)
± (10K + 0,1 % of set range)
± (6K + 0,1 % of set range)
Accessories
Note
2028820000
Cross-connector for power supplies and markers – refer to Accessories
D.69
Signal converters
WAVESERIES – Frequency signal isolator/converter configurable
WAVEanalog PRO Frequency
WAVEANALOG PRO Frequency
delivers settings help, for any
input and output values.
The input range is set using
the DIP switches (a frequency
generator is not required)
D
There are 2 different methods:
1. L
ower measuring frequency = 0 Hz
•Choose operating mode “= … fmax”
S2.3 = 0 and S2.4 = 0
•Set the upper measuring frequency
using DIP switches S1 and S2.1,
S2.2 (see table)
• That’s all!
2. Lower measuring frequency ≠ 0 Hz
•First the lower measuring frequency
must be saved. Select mode “save
fmin”. S2.3 = 1 and S2.4 = 0. Set
the frequency using DIP switches S1
and S2.1, S2.2 (see table) To save
the frequency, briefly connect the
module to the power supply.
•Select mode “fmin … fmax”
S2.3 = 0 and S2.4 = 1
•Set the upper measuring frequency
using DIP switches S1 and S2.1,
S2.2 (see table).
• That’s all!
Adjusting input range using
frequency device to be measured:
•Select the switch setting for saving
the frequency: S2.1 = 0, S2.2 = 1,
S2.3 = 1 and S2.4 = 1
• Apply min. frequency to the module
•Connect the module to the power
supply
•The LED lights up when the input
frequency is being measured. If the
LED goes off, the frequency has
been saved and the module can be
disconnected from the power supply
again.
•Repeat with max. frequency: S2.1 = 1,
S2.2 = 0, S2.3 = 1 and S2.4 = 1
•Select special range:
S2.1 = 1, S2.2 = 1, S2.3 = 1 and
S2.4 = 1
3-wire initiator wit
3-wire initiator wit
3-wire initiator with PNP–Output
(1) +15 V
(1) +15 V
(2) PNP
3-wire initiator with PNP–Output
(2) PNP
(1)
(3) +15
NPN V/ Namur
(3) NPN / Namur
(2)
PNP
(4)
GND
(1)
+15 V
(4) GND
(3)
(2) NPN
PNP / Namur
(4)
(3) GND
NPN / Namur
3-wire initiator wit
2-wire initiator
2-wire initiator
(residual current < 1 mA)
(residual current < 1 mA)
3-wire initiator with NPN–Output
3-wire initiator with NPN–Output
(1) +15 V
(1)
3-wire initiator with NPN–Output
(2) +15
PNP V
(2)
(3) PNP
NPN / Namur
(1) NPN
+15 V/ Namur
(3)
(4)
GND
(2) GND
PNP
(4)
(3) NPN / Namur
(4) GND
3-wire initiator with NPN output and external supply
U=24 V
3-wire initiator with NPN output and external supply
(1) +15 V
(1)
+15
V
3-wire initiator with NPN output
supply
(2)and
PNPexternal
(2)
(3) PNP
NPN / Namur
(1) NPN
+15 V/ Namur
(3)
(4)
GND
(2) GND
PNP
(4)
(3) NPN / Namur
U=24 V
(4) GND
U=24 V
Namur–Initiator
Namur–Initiator
U=24 V
Namur–Initiator
U=24 V
N
(1) +15 V
(1) +15 V
(2) PNP
(2) PNP
(1)
(3) +15
NPN V/ Namur
(3) NPN / Namur
(2)
PNP
(4)
GND
(1)
+15 V
(4) GND
(3)
(2) NPN
PNP / Namur
(4)
(3) GND
NPN / Namur
(1) +15 V
3-wire initiator with PNP output
supply
(1)and
+15external
V
(2)
PNP
(2) NPN
PNP / Namur
(3)
(1) GND
+15 V/ Namur
(3)
NPN
(4)
(2) GND
PNP
(4)
(3) NPN / Namur
U=24 V
(4) GND
U=24 V
Namur–Initiator
N+
Namur–Initiator
N+
NNN+
N-
N
Namur–Initiator N
N
N
N
NN
(4) GND
(1) +15 V
3-wire initiator with PNP–Output
(1) PNP
+15 V
(2)
(2) NPN
PNP / Namur
(3)
(1) GND
+15 V/ Namur
(3)
NPN
(4)
(2) GND
PNP
(4)
(3) NPN / Namur
(4) GND
(1) +15 V
(1) PNP
+15 V
(2)
(2) NPN
PNP / Namur
(3)
(1) GND
+15 V/ Namur
(3)
NPN
(4)
(2) GND
PNP
(4)
(3) NPN / Namur
(4) GND
U=24 V
U=24 V
Namur–Initiator
Namur–Initiator
U=24 V
Namur–Initiator
Namur–Initiator
Namur–Initiator
U=24 V
Namur–Initiator
Namur–Initiator
(1) +15 V
(1) +15 V
(2) PNP
(2) PNP
(1)
(3) +15
NPN V/ Namur
(3) NPN / Namur
(2)
(4)
GND
(1) PNP
+15 V
(4)
GND
(3)
(2) NPN
PNP / Namur
(4)
(3) GND
NPN / Namur
3-wire initiator with PNP output and
(4)external
GND supply
3-wire initiator with PNP output and external supply
U=24 V
Push pull output cascade
3-wire initiator wit
2-wire initiator
2-wire initiator
3-wire initiator with PNP–Output
3-wire initiator with PNP–Output
(residual
< 1 mA)
Push
pull current
output cascade
Push pull output
U=24cascade
V
3-wire initiator wit
(4) GND
U=24 V
(residual current < 1 mA)
(residual current < 1 mA)
U=24 V
3-wire initiator wit
3-wire U=24
initiator
V wit
3-wire initiator with NPN–Output
(1) +15 V
(1) +15 V
(2) PNP
3-wire initiator with NPN–Output
(2) PNP
(1)
(3) +15
NPN V/ Namur
(3) NPN / Namur
(2)
PNP
(4)
GND
(1)
+15 V
(4) GND
(3)
(2) NPN
PNP / Namur
(4)
(3) GND
NPN / Namur
U=24cascade
V
Push pull output
(1) +15 V
(1)
(2) +15
PNP V
(2)
(3) PNP
NPN / Namur
(1) NPN
+15 V/ Namur
(3)
(4)
GND
(2) GND
PNP
(4)
(3) NPN / Namur
(4) GND
U=24 V
U=24 V
3-wire initiator with NPN–Output
3-wire initiator with NPN–Output
(residual current < 1 mA)
2-wire initiator
3-wire initiator wi
(4) GND
Push
pull output
(residual
currentcascade
< 1 mA)
Push pull output cascade
U=24 V
U=24cascade
V
Push pull output
2-wire initiator
2-wire initiator
D.70
3-wire initiator with PNP–Output
3-wire initiator with PNP–Output
Connection
configuration for the sensors
(1) +15 V
(1)
(2) +15
PNP V
(2)
(3) PNP
NPN / Namur
(1) NPN
+15 V/ Namur
(3)
(4)
GND
(2) GND
PNP
(4)
(3) NPN / Namur
(4) GND
2028820000
WAVESERIES - Frequency signal isolator / converter configurable
PRO Frequency
• 3-way isolation
• Max. input frequency: 100 kHz
• Input and output ranges can be adjusted via DIP
switches
• No calibration necessary
• Supplies the NAMUR sensor
• Programmable custom range
• Can be adjusted and set using the WAVETOOL software,
download from www.weidmueller.com
UL Class I, Div. 2
Signal converters
f/DC isolator/converter
Selecting the
operating mode
Operating mode
f
U/I
0 … fmax
fmin … fmax
saving
of fmin
VC
Switch 2
3 4
◼
◼
◼
◼
◼
◼
Input
Sensor
Rated input level
2-, 3-wire PNP/NPN, Namur initiator, push-pull step, Frequency
Threshold/hysteresis: Namur: approx. 1.7 mA/approx. 0.2 mA; NPN:
approx. 6.5 V/approx. 0.2 V; PNP: approx. 6,7 V/approx. 0.5 V
Output
Output voltage / Output current
Load impedance, voltage/current
Offset current / Offset voltage
Status indicator
General data
Configuration
0...5 V, 0...10 V, adjustable / 0...20 mA, 4...20 mA, adjustable
≥ 1 kΩ / ≤ 600 Ω
max. 100 µA / max. 0.05 V
Green LED
DIP switch (measurement range 0…15900 Hz), Frequency generator
(measurement range 0…100 kHz)
24 V DC ± 25 %
Max. 1.6 W at IOUT = 20 mA
< 0.2% of output range
Max. 200 ppm/K of output range
360 ms + 2 times the period time of input frequency
0 °C...55 °C
CE; cULus; cULusEX; EAC
Supply voltage
Power consumption
Accuracy
Temperature coefficient
Step response time
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
Selecting
the frequency
Switch1
1 2 3
A
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6, EN 61326
300 V
6 kV
4 kVeff / 5 s
III
2
≥ 5.5 mm
4
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
Output
0…10 V
0…20 mA
4…20 mA
0…5 V
Selecting
the frequency
Switch 1
5 6 7
B
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
C
x1
x10
x100
x1000
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
Selecting
the frequency
Switch 2
1
2
◼
◼
◼
◼
◼
◼
◼
◼
Selecting the output
Switch 2
5
6
7
8
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
Tension clamp connection
1.5/0.5/2.5
112.4/12.5
◼
◼
230 V AC
7 8
Order No.
8581180000
8581190000
Registering motor
revolutions using
Namur sensor
8581180000/8581190000
5 6
WAVEANALOG
PRO FREQUENCY
Screw connection
Tension-clamp connection
Qty.
1
1
◼
Application
24 V DC
Type
WAS4 PRO Freq
WAZ4 PRO Freq
◼
= on
= off
∼
Ordering data
4
◼
Note
SPS
0…20 mA
mm²
mm
Screw connection
2.5/0.5/2.5
112.4/12.5
8
◼
◼
Special range (frequency generator is required)
Switch 2
Function
1
2
3
◼
◼
◼
save min. frequency
◼
◼
◼
save max. frequency
◼
◼
◼
select special range
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
D
f = (A+B) x C
Technical data
1 2
3 4
N–
Accessories
Note
2028820000
Cross-connector for power supplies and markers – refer to Accessories
N+
Namur
activated: <= 1,2 mA
not activated: >= 2,1 mA
D.71
WAVESERIES - Current measuring transducer
Signal converters
Analogue output
1/5/10 A AC
1/5/10 A AC 4...20 mA
Loop-powered
• Monitors AC currents
• Input and output are electrically isolated
• Input and output ranges adjustable via DIP switch
+ 24V 7
I AC
2
U/I
3
IN
VC
D
Output 8
I
0V 9
U/I
+ 24 V 7
2
3
IN
I
4...20 mA 9
I
Technical data
Input
Input current
Input frequency
Max. current
Voltage of measuring circuit
Sensor
Output
Output current / Output voltage
Offset current
Output signal limit
Load impedance, voltage/current
Step response time
Accuracy
Temperature coefficient
Status indicator
General data
Configuration
Supply voltage
Current consumption
Current-carrying capacity of cross-connect.
Ambient temperature / Storage temperature
Default setting
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Pollution degree
Overvoltage category
Clearance & creepage distances
Insulation voltage
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
0...1 A AC/ 0...5 A AC/ 0...10 A AC
50...60 Hz
100 A for 1s
250 V AC
Transforming (internally)
0...1 A AC/ 0...5 A AC/ 0...10 A AC
50...60 Hz
100 A for 1s
250 V AC
Transforming (internally)
0...20 mA / 0...10 V
max. 100 µA
Approx. 13 V or 24 mA
≥ 1 kΩ / ≤ 600 Ω
typ. 700 ms
0.5 % FSR
≤ 200 ppm/K
LED ON: OK; FLASHING: signal out of range;
LED OFF: Error
4...20 mA (current loop) /
max. 100 µA
Approx. 24 mA
/ ≤ 600 Ω
typ. 700 ms
0.5 % FSR
≤ 200 ppm/K
LED ON: OK; FLASHING: signal out of range;
LED OFF: Error
DIP switch
24 V DC ± 10 %
40 mA @ IOUT = 20 mA
≤2A
/ 0 °C...50 °C / -20 °C...70 °C
0...5 A AC, 4...20 mA
CE; cULus; EAC
DIP switch
13...30 V DC, via output current loop
DIN EN 50178 (secure separation)
EN 55011, EN 61000-6
300 V
6 kV
2
III
≥ 5.5 mm
4 kVeff / 5 s
DIN EN 50178 (secure separation)
EN 55011, EN 61000-6
300 V
6 kV
2
III
≥ 5.5 mm
4 kVeff / 5 s
Screw connection
2.5/0.5/2.5
92.4/22.5
/ 0 °C...50 °C / -20 °C...70 °C
0...5 A AC, 4...20 mA
CE; cULus; EAC
Tension clamp connection
1.5/0.5/2.5
92.4/22.5
Screw connection
2.5/0.5/2.5
112.4/22.5
Tension clamp connection
1.5/0.5/2.5
112.4/22.5
Ordering data
Screw connection
Tension-clamp connection
Type
WAS1 CMA 1/5/10A ac
WAZ1 CMA 1/5/10A ac
Qty.
1
1
Order No.
8523400000
8523410000
Type
WAS1 CMA LP 1/5/10A ac
WAZ1 CMA LP 1/5/10A ac
Qty.
1
1
Order No.
8528650000
8528660000
Note
Accessories
Note
D.72
Cross-connectors for power supplies and markers – refer to Accessories
Cross-connectors for power supplies and markers – refer to Accessories
2028820000
WAVESERIES - Current measuring transducer
1/5/10 A AC 4...20 mA
• Monitors AC currents
• Input and output are electrically isolated
• Input and output ranges adjustable via DIP switch
• No calibration required
• ATEX II 3 G nL IIC T4
• UL Class I, Div.2
Loop-powered
Signal converters
Analogue output
+ 24 V 7
I AC
2
U/I
3
VC
IN
I
4...20 mA 9
I
D
Technical data
Input
Input current
Input frequency
Max. current
Voltage of measuring circuit
Sensor
Output
Output current / Output voltage
Offset current
Output signal limit
Load impedance, voltage/current
Step response time
Accuracy
Temperature coefficient
Status indicator
0...1 A AC/ 0...5 A AC/ 0...10 A AC
50...60 Hz
100 A for 1s
250 V AC
Transforming (internally)
4...20 mA (current loop) /
max. 100 µA
Approx. 24 mA
/ ≤ 600 Ω
typ. 700 ms
0.5 % FSR
≤ 200 ppm/K
LED ON: OK; FLASHING: signal out of range;
LED OFF: Error
General data
Configuration
Supply voltage
Current consumption
Current-carrying capacity of cross-connect.
Ambient temperature / Storage temperature
Default setting
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Pollution degree
Overvoltage category
Clearance & creepage distances
Insulation voltage
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
DIP switch
13...30 V DC, via output current loop
/ 0 °C...50 °C / -20 °C...70 °C
0...5 A AC, 4...20 mA
CE; cULusEX; DEMKOATEX; EAC
DIN EN 50178 (secure separation)
EN 55011, EN 61000-6
300 V
6 kV
2
III
≥ 5.5 mm
4 kVeff / 5 s
mm²
mm
Screw connection
2.5/0.5/2.5
112.4/22.5
Ordering data
Screw connection
Tension-clamp connection
Type
WAS1 CMA LP 1/5/10A EX
Qty.
1
Order No.
8975590000
Note
Accessories
Note
2028820000
Cross-connectors for power supplies and markers – refer to Accessories
D.73
WAVESERIES - Voltage measuring transducer
VMA V AC
• 3-way isolation
• Max. measuring voltage 450 V ACeff
• Output range selected via DIP switch
• No calibration necessary
Uac
0V
0 30V
0 70V
0 130V
0 250V
0 450V
U/I
VC
0 10V 7
0/4 20mA 8
GND1 9
SW1
SW2
+24V 10
0 20mA 4 2 0mA
OFF
ON
OFF
ON
GND2 11
Technical data
Application
Input
Input voltage
Input frequency
Max. voltage
Output
Output voltage / Output current
Offset voltage / Offset current
Load impedance, voltage/current
Accuracy
Temperature coefficient
Step response time
Status indicator
General data
Configuration
Supply voltage
Current consumption
Current-carrying capacity of cross-connect.
Default setting
Ambient temperature / Storage temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
0...30 / 0...70 / 0...130 / 0...250 / 0...450 V AC
40...400 Hz sinus
45 / 100 / 180 / 270 / 475 V AC (briefly)
∼
24 V DC
SPS
10 11 12
0...10 V / 0...20 mA
max. 0.02 V / max. 40 µA
≥ 1 kΩ / ≤ 600 Ω
1,3 % (40...60 Hz) typ. 1 %; 2 % (70...400 Hz) typ. 1,5 %
≤ 250 ppm/K
< 300 ms
Green LED
7
L1
L2
L3
8
9
M
3⁓
U
1
2
3
4
5
6
DIP switch
24 V DC ± 25 %
40...30...24 mA @ IOUT =20 mA
≤2A
0...10 V / 0...20 mA
/ 0 °C...50 °C / -20 °C...70 °C
CE; cULus; EAC
Impulse withstand voltage
DIN EN 50178
EN 61000-2-6, EN 61000-6, EN 61326
supply/output: 300 V;
input/output, supply/output: 600 V
Supply⁄output: 4 kV; input⁄output, supply⁄input: 6 kV
Insulation voltage
Overvoltage category
Pollution degree
Clearance & creepage distances
4 kVeff / 5 s
III
2
Supply/output: 3 mm; input/output, supply/output: 5.5 mm
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
230 V AC
0...20 mA
D
1
2
3
4
5
6
WAVECONTROL
VMA Vac
8581220000/
85811230000
Signal converters
Analogue output
mm²
mm
Screw connection
2.5/0.5/2.5
112.4/22.5
Tension clamp connection
1.5/0.5/2.5
112.4/22.5
Ordering data
Screw connection
Tension-clamp connection
Type
WAS2 VMA V ac
WAZ2 VMA V ac
Qty.
1
1
Order No.
8581220000
8581230000
Note
Accessories
Note
D.74
Cross-connector for power supplies and markers – refer to Accessories
2028820000
D
2028820000
D.75
Signal converters
Signal converters
Isolating converter for serial interfaces
Isolating converters for serial interfaces
Isolating converters for serial interfaces RS232/
RS485/422 or TTY
D
Serial interface are used for exchanging data between data
processing systems, controllers and peripherals. The WDS2
interface isolating converter is particularly well suited for
harsh conditions located near to the process. Versions are
available for a variety of industrial applications:
• RS232/RS422 or RS485
• RS232/TTY
The thin (22.5 mm wide) rail-mounted modules come with
a 9-pole SUB-D connector for the RS232 connection and
a shield connection for the RS485/422 or TTY signal line.
In order to ensure high transmission security, the serial
interface isolating converters are equipped with high-quality
4-kV 3-way electrical isolation.
•Easy to service: the electronic components can be
removed from the housing/base without using any tools.
The terminating resistor can be selected with DIP switch.
•High data transmission speeds up to 115 kBit/s and
freely adjustable
•Secure connection: 9-pole Sub-D connector for the
RS232 interface.
For the serial RS485/422 and TTY connection, the user
can connect the shield using the LLBU or the EMC Set
(1067470000).
D.76
2028820000
Isolating converter for serial interfaces
RS232/RS485/422
RS232/RS485/422
RS232
U/I
RS485
RS422
VC
Signal converters
• 3-way isolation
• RS232 connection via SUB-D 9
• RS485/422, shield connection via KLBUE
• Switchable DTE or DCE assignment
• Bi-directional communication
2 - T/R (A)
3 - T/R (B)
RS232
RS485
VCC
2 - T/R (A)
3 - T/R (B)
RS485
RS232
6 - GND
SHLD
WDS2 RS232/RS485/422
VCC
WDS2 RS232/RS485/422
D
Technical data
RS232
Connection type / Input current
Assignment
RS485/422
Terminating resistors
Type of connection
Bit distortion
Bit delay
Control of data direction
Shield connection
Status indicator
Transmission rate
Transmission channels
SUB-D9 (male plug) /
DTE/DCE switchable with DIP switch
Pull-down/pull-up via DIP switch
Screw connection
<5%
≤ 3 µs
Automatic or via RS232 RTS/CTS
KLBÜ 4-6/Z1
LED green: supply voltage, TxD, RxD
2.4, 4.8, 9.6, 19.2, 57.6, 115.2 kBaud, 8 bit or 8 bit + parity bit
Half-duplex (RS485 2-wire)
Full-duplex (RS485 4-wire and RS422)
Max. 1200 m twisted pair
Transmission distance
General data
Configuration
Supply voltage
Power consumption
Ambient temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
DIP switch
24 V DC ± 20 %
ca. 1.5 W
0 °C...55 °C
CE; cULus; EAC; GL
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6-2, EN 61000-6-4
between adjacent electric circuits: 300 V
between electric circuits and PE: 150 V
4 kV
2
III
Between neighbouring circuits: 3 mm
Between the circuits and PE: 1.5 mm
2 kV DC / 1 min.
Impulse withstand voltage
Pollution degree
Overvoltage category
Clearance & creepage distances
Insulation voltage
Screw connection
2.5 / 0.5 / 2.5
/ 22.5 / 112.4
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
Ordering data
Screw connection
Type
WDS2 RS232/RS485/422
Qty.
1
Order No.
8615700000
Note
Accessories
Note
2028820000
Cross-connector for power supplies and markers – refer to Accessories
D.77
Isolating converter for serial interfaces
Signal converters
RS232/TTY
RS232/TTY
• 3-way isolation
• RS232 connection via SUB-D 9
• TTY shield connection via KLBUE retaining clip
• Switchable DTE or DCE assignment
• Bi-directional communication
RS232
RS232
U/I
TTY
TTY
VC
D
VCC
5 T+
6 T2 R+
3 R-
R+ 2
R- 3
T+ 5
T- 6
TTY
RS232
SHLD
WDS2 RS232/TTY
VCC
WDS2 RS232/ TTY
Technical data
RS232
Connection type / Input current
Assignment
TTY
Type of connection
Bit distortion
Bit delay
Load
Shield connection
Status indicator
Transmission rate
Transmission channels
Transmission distance
General data
Configuration
Supply voltage
Power consumption
Ambient temperature
Storage temperature
Approvals
Insulation coordination
Standards
EMC standards
Rated voltage
SUB-D9 (male plug) /
DTE/DCE switchable with DIP switch
Screw connection
< 1.5%
≤ 3 µs
≤ 500 Ω
KLBÜ 4-6/Z1
LED green: supply voltage, TxD, RxD
19.2 kBit/s
Full-duplex
Max. 1000 m twisted pair
DIP switch
24 V DC ± 20 %
ca. 0.8 W
0 °C...55 °C
-20 °C...85 °C
CE; cULus; EAC; GL
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6-2, EN 61000-6-4
between adjacent electric circuits: 300 V
between electric circuits and PE: 150 V
4 kV
2
III
Between neighbouring circuits: 3 mm
Between the circuits and PE: 1.5 mm
2 kV DC / 1 min.
Impulse withstand voltage
Pollution degree
Overvoltage category
Clearance & creepage distances
Insulation voltage
Screw connection
2.5 / 0.5 / 2.5
/ 22.5 / 112.4
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
Ordering data
Screw connection
Type
WDS2 RS232/TTY
Qty.
1
Order No.
8615690000
Note
Accessories
Note
D.78
Cross-connector for power supplies and markers – refer to Accessories
2028820000