Download

WAVE TTA_LIT0903_DS:Layout 1
2/9/09
3:32 PM
Page 1
Datasheet
WAV E S E R I E S WAV E T TA
NEW
Most commonly used temperature sensors and DC inputs are
accepted, and the TTA also allows the user to define specific
characteristics, so special sensor types and linearization can
easily be accommodated.
To help simplify installation and loop commissioning, test
terminals are provided to permit input and output signal
checks without removing cabling.
For linearized and/or isolated analog outputs, the user has a
choice of standard or scalable DC current and voltage ranges.
These can be set as either direct or reverse acting. The user
can also select upscale or downscale output in the event of a
sensor break or an open circuit in the input.
The WAVE TTA is a “universal” transmitter trip amplifier. It is
part of Weidmuller’s well-established WAVESERIES family of
analog signal conditioners, which are widely used in process
and factory automation applications.
The TTA provides two independently settable changeoverrelay outputs, for use as high and low level alarms or control
points.
Configuring the versatile TTA to change input and output
parameters is simple, and performed from a computer via an
interface (CBX100 USB). The necessary TTA SET software
comes free of charge with the WAVE TTA.
The WAVE TTA is an intelligent signal
• isolator
• converter
• transmitter
• linearizer
• trip amplifier
The WAVE TTA accepts voltage supply between 18 and 264 V
AC or DC.
The TTA will function accurately over a wide ambient temperature range, and over a wide supply voltage range, and with
most types of sensor inputs. For two wire current transmitters,
24 V DC power is provided. Alternatively the TTA can be a
passive input for the current source.
The TTA comes in a black WAVESERIES UL 94 V0 housing,
for mounting on TS35 DIN rail. Pluggable connectors, allow
screw or tension clamp wiring. A screwdriver-releasable front
flap gives access to the configuration interface socket.
The WAVE TTA is CE and cULus approved.
Canada
Mexico
United States
Weidmuller, Canada
10 Spy Court
Markham, Ontario L3R 5H6
Telephone: (800) 268-4080
Facsimile: (905) 475-2798
Email: [email protected]
Website: www.weidmuller.ca
Weidmuller, Mexico
Blvd. Hermanos Serdán 698
Col. San Rafael Oriente
Puebla, Puebla, Mexico
C.P. 72029
Telephone: 01 222 2686267
Facsimile: 01 222 2686219
Email: [email protected]
Website: www.weidmuller.com.mx
Weidmuller
821 Southlake Blvd.
Richmond, Virginia 23236
Telephone: (800) 849-9343
Facsimile: (804) 379-2593
Email: [email protected]
Website: www.weidmuller.com
WAVE TTA_LIT0903_DS:Layout 1
2/9/09
3:32 PM
Page 2
WAV E S E R I E S
WAV E T TA
WAVE TTA
WAS6 TTA / WAZ6 TTA
Universal signal converter and trip amplifer
• Inputs and outputs configured via PC
• Universal inputs
• Loop-powered or passive mA input
• Powered from AC or DC supply
Analog Inputs
3 Port Isolation
J V, I
V, I
PS
+24 V DC
Relay
Channel 1
Relay
Channel 2
Output
0 ... 11 V /
0 ... 22 mA
18-264 V AC/DC supply
Technical data
Typical functions
Input
Type, thermocouple
Type, RTD
B, E, J, K, L, N, R, S, T (IEC 60584)
PT100, PT1000, (EN 60571) Ni100, Ni1000, (JIS1604), Cu10,
Cu25, Cu50, Cu100 (DIN 43760) 2-/3-/4-conductor
100 Ω…100 kΩ
10 Ω…5 kΩ
2 Hz…100 kHz
-200…500 mV (min. span 4 mV),
-20…50 V DC (min. span 0.5 V)
-20…50mA (min. span 1mA)
24 V DC / 22 mA
configurable /
< 0.1 % span (DC, RTD); 0.2 % span (or 1 °C) + CJ error
Potentiometer / current
Resistance
Frequency
Voltage
Current
Current Loop Supply
Output signal during wire break / max.
Accuracy
Isolator
I
I, V
PS
Converter
Temperature coefficient
< 0.1 % / K (DC, RTD); < 0.1 % FSR / K + CJ error 0.07 °C/K
(thermocouples)
Can be set from -10…+10 V (min. span 2.5 V)
Can be set from 0…20 mA (min. span 5 mA)
> 10 kΩ @ 0…10 V / > 20 kΩ @ -10…+10 V
< 700 Ω
Direct or inverted
Linear, x1/2, x3/2, x5/2 or user-defined curve (101 points)
PS
Transmitter
J
2 x 1 CO contact (hard gold plated)
AgSnO 5µm Au
250 V
3A
Supply voltage
Power consumption
Operating temperature
Storage temperature
Step response time
I, V
PS
18…264 V AC/DC
< 3.5 W
-40 °C…+70 °C
-40 °C…+85 °C
50 ms…1 sec (RTD, mV inputs), 110 ms…1 sec
(V, mA inputs)
CE; cULus
5…95 % non-condensing
Approvals
Humidity
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Pollution severity
Overvoltage category
Clearance & creepage distance
Clamping range (rated- / min. / max)
Length x width x height
f, I, V
I, V
Output (analog)
Output voltage
Output current
Load resistance, voltage
Current
Signal output
Transmit function
Output (digital)
Type
Contact base material
Max. switching voltage AC
Continuous current
General data
Linearizer
I, V
I, V
PS
EN 50178 (protective separation)
EN 55011, EN 61000-6
300 V
6 kV between supply & input/output, 4 kV between input & output
2
III
≥ 5.5 mm (1 mm input/output)
mm2
mm
Trip amplifier
J
PS
2.5 / 0.5 / 2.5
92.4 x 45 x 112.4
Ordering data
Screw connection
Tension clamp connection
Type
WAS6 TTA
WAZ6 TTA
Part No.
8939670000
8939680000
Accessories
Note
2
CBX100 USB Interface – 7940025031
Connects the WAVE TTA with a PC for calibration
Subject to technical changes • 2/09-2.5M-LIT0903