Download

Total Counter/Time Counter (DIN 48 x 24)
H7GP
CSM_H7GP_DS_E_4_4
DIN 48 x 24-mm Total Counter/Time Counter
with Easy-to-read Displays and Water and
Oil Resistance Equivalent to IP66
• High-visibility, negative transmissive LCD display with 8.5-mmhigh characters and built-in red LED backlight at low power
consumption.
• IP66 with oil resistance and NEMA 4 protection achieved by
unifying the front with the case and by using oil-resistant parts
and materials.
• Compact (80 mm) body.
• Just change a switch setting for either an NPN or PNP input.
• Supports both external resetting and manual resetting.
• Finger-protection terminal block cover prevents electrical shock
and conforms to VDE0106, Part 100.
• Certified for UL and CSA safety standards.
• Complies with EMC standards (EN 61326) and CE Marking.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
■ Model Number Legend
H7GP-@@@
1 2 3
3. Case Color of Front Section
None: Light gray (Munsell 5Y7/1)
B:
Black
1. Classification
C:
Total counter
T:
Time counter
2. Supply Voltage
None: 100 to 240 VAC
D:
12 to 24 VDC
Ordering Information
■ List of Models
Total counter
Supply voltage
6-digit total counter
Light gray
Black
100 to 240 VAC
H7GP-C
H7GP-CB
12 to 24 VDC
H7GP-CD
H7GP-CDB
Time counter
Supply voltage
6-digit time counter
Light gray
Black
100 to 240 VAC
H7GP-T
H7GP-TB
12 to 24 VDC
H7GP-TD
H7GP-TDB
1
H7GP
Specifications
■ Ratings
Item
6-digit total counter
H7GP-C
6-digit time counter
H7GP-CD
H7GP-T
H7GP-TD
Rated supply voltage
100 to 240 VAC (50/60 Hz) 12 to 24 VDC (see note 1) 100 to 240 VAC (50/60 Hz) 12 to 24 VDC (see note 1)
External power supply
50 mA at 12 VDC
Operating voltage range
85% to 110% of rated supply voltage
Power consumption
100 to 240 VAC: 6.5 VA max.
12 to 24 VDC:
0.6 W max.
Dimensions
48 x 24 x 80 mm (W x H x D)
Mounting method
Flush mounting
External connections
Screw terminals
Degree of protection
Panel surface: IP66 with oil resistance and NEMA Type 4 (indoors).
Display
7-segment, negative transmissive LCD (with red backlight)
Digits
6 digits (8.5-mm-high characters)
---
50 mA at 12 VDC
Input mode
Up (increment)
Accumulative
Max. counting speeds
30 Hz or 5 kHz (selected via DIP switch)
---
---
Counting range
0 to 999999
---
Time specification
---
0.1 to 99999.9 h/1 s to 99 h 59 min 59 s
(selected via DIP switch)
Timing accuracy
---
±100 ppm (–10°C to 55°C)
Memory backup
EEP-ROM (overwrites: 200,000 times min.) that can store data for 20 years min.
Input
Input signals
Count, reset, and key protection (see note 2)
Input method
No-voltage input (NPN transistor input) or voltage input (PNP transistor input) (selected via DIP switch)
Start, reset, and key protection (see note 2)
Count, reset,
start
No-voltage input (NPN transistor input)
Short-circuit (ON) impedance:
1 kΩ max.
Short-circuit (ON) residual voltage:2 VDC max.
Open (OFF) impedance:
100 kΩ min.
Voltage input (PNP transistor input)
Short-circuit (ON) impedance:
1 kΩ max.
ON voltage:
9 to 24 VDC
OFF voltage:
5 VDC max.
Open (OFF) impedance:
100 kΩ max.
Key protection No-voltage input (NPN transistor input)
Short-circuit (ON) impedance:
1 kΩ max.
Short-circuit (ON) residual voltage:0.5 VDC max.
Open (OFF) impedance:
100 kΩ min.
Input response
speed
Reset
20 or 1 ms (automatically switched according to counting 20 ms
speed)
Start
---
Key protection Approx. 1 s
Reset system
20 ms
Approx. 1 s
External and manual resets
Note: 1. Contains 20% ripple (p-p) max.
2. Only a non-voltage input (NPN transistor) is possible for the key protection input. The key protection input will be a non-voltage input even
if the NPN/PNP input mode is set to PNP. Key protection is used to prohibit operating the Reset Key. The reset input terminals will still be
functional.
2
H7GP
■ Characteristics
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-carrying metal parts
(AC model)
1,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-carrying metal parts
(DC model)
2,000 VAC, 50/60 Hz for 1 min between power terminals and control input terminals (AC model)
Impulse withstand voltage 3 kV (between power terminals) (1 kV for 12-to-24-VDC models)
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) (1.5 kV for 12-to-24-VDC
models)
Noise immunity
±1.5 kV (between AC power terminals), ±480 V (between DC power terminals),
±480 V (between input terminals);
square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Static immunity
Display:
Vibration resistance
Destruction: 10 to 55 Hz with 0.75-mm single amplitude, 2 hours each in three directions
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude, 10 minutes each in three directions
Shock resistance
Destruction: 294 m/s2 each in three directions
Malfunction: 196 m/s2 each in three directions
Ambient temperature
Operating: –10°C to 55°C (with no icing)
Storage: –25°C to 65°C (with no icing)
Ambient humidity
Operating: 35% to 85%
EMC
(EMI)
Emission Enclosure:
Emission AC Mains:
(EMS)
Immunity ESD:
Approved standards
UL508 (note 2), CSA C22.2 No.14 (note 2), conforms to EN61010-1, VDE0106/P100
Case color
Rear section: Gray smoke; Front section: 5Y7/1 (light gray) or N1.5 (black)
Weight
Approx. 75 g
Malfunction:8 kV
Destruction:15 kV
DIP switch: Malfunction:4 kV
Destruction:8 kV
EN61326-1 (note 1.)
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61326-1 (note 1.)
EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference:
EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3);
10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3)
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (according to EN61000-6-2)
Immunity Burst:
EN61000-4-4: 2 kV power-line (level 3);
2 kV I/O signal-line (level 4)
Immunity Surge:
EN61000-4-5: 1 kV line to lines (power and output lines) (level 2);
2 kV line to ground (power and output lines) (level 3)
Immunity Voltage Dip/Interruption: EN61000-4-11: 0.5 cycle, 100% (rated voltage)
Note: 1. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
2. UL508 and CAN/CSA-C22.2 No.14 certification conditions
• Power supply 100 to 240VAC types
Ambient temperature 30°C Single mounting
• Power supply 12 to 24VDC types
Ambient temperature 40°C Single mounting
3
H7GP
Connections
■ Terminal Arrangement
Note: Non-contact input is also available.
AC Models
H7GP-C
External power supply
12 VDC 50 mA max.
100 to 240 VAC
Power
supply
Power
supply
5
6
7
1
2
3
Reset
input
Count
input
Key protection
input
0V
H7GP-T
External power supply
12 VDC 50 mA max.
100 to 240 VAC
Power
supply
Power
supply
8
5
6
7
8
4
1
2
3
4
12 VDC
Key protection
input
Unused
Reset
input
0V
Count
input
12 VDC
Unused
NPN mode
NPN mode
PNP mode
PNP mode
DC Models
H7GP-CD
H7GP-TD
12 to 24 VDC
0V
Power
supply
12 to 24 VDC
Unused
Unused
0V
Power
supply
Unused
Unused
5
6
7
8
5
6
7
8
1
2
3
4
1
2
3
4
Reset
input
Count
input
Reset
input
Start
input
Key protection
input
NPN mode
Unused
PNP mode
Key protection
input
NPN mode
Unused
PNP mode
4
H7GP
Operation
■ DIP Switch Settings
Set all DIP switches before mounting the Counter to a control panel.
All switches are set toward the display panel before shipping.
H7GP-T/-TD
Switch
H7GP-C/-CD
Switch
Item
Function
3 (On right side
from front)
Input mode (note
1)
Display side
NPN
Terminal side
PNP
4 (On left side
from front)
Counting speed
(note 1)
Display side
30 Hz
Terminal side
5 kHz
Item
Function
3 (On right side
from front)
Input mode
(note 1)
Display side
Terminal side
NPN
PNP
4 (On left side
from front)
Time range
(note 1)
Display side
99999.9h
(note 2)
Terminal side
99 h 59 min
59 s
Note: 1. When the setting has been changed, turned power off and
on to continue. The display will show “0” when the power is
turned back on.
2. The decimal point will flash every second when “99999.9 h”
is set.
■ Operating Modes
Total Counters
Time Counters
Reset input
Reset input
Count input
Start input
999999
99999.9 h
(see note)
Display
Display
0
0.0h
Note: The count value will return to "0" when "999999" is
exceeded.
The display and output are turned OFF when the power
supply turns OFF, but the count value is stored internally.
Note: Display values are shown for full scale set to 99999.9 h.
The count value will return to "0" when "99999.9" is
exceeded.
The display and output are turned OFF when the power
supply turns OFF, but the count value is stored internally.
Nomenclature
4
1. Reset Key
Resets the count value, but will not operate while
the keys are protected.
2
3
1
2. Key Protection Indicator
Lit while the keys are protected. (Reset Key is
disabled.).
3. NPN/PNP DIP Switch
(Count or start with reset)
When the setting has been changed, turned power
off and on to continue. The display will show "0"
when the power is turned back on. See below for
details.
4. Counting Speed DIP Switch (H7GP-C)
Time Range DIP Switch (H7GP-T)
When the setting has been changed, turned power
off and on to continue. The display will show "0"
when the power is turned back on. Refer to DIP
Switch Setting for details.
5
H7GP
Dimensions
Note: All units are in millimeters unless otherwise indicated.
H7GP-C
H7GP-T
Panel Cutouts
Panel cutouts are as shown below
(according to DIN43700).
M3.5 terminal screw
50 min.
5.0 min.
45 +0.6
0
45 +0.6
0
22.2 +0.3
0
22.2 +0.3
0
Terminal cover (provided)
Note: 1. The mounting panel thickness should
be 1 to 6 mm.
2. Water resistance will be lost if
Counters are mounted side-by-side.
3. The terminal screws are M3.5.
(Theeffective thread length is 6 mm.)
4. When horizontally mounting Counters
side-by-side, leave at least 50 mm
between any two Counters.
With Flush Mounting Bracket
Y92S-32 rubber
packing (provided)
Panel
Y92F-32 flush mounting
adaptor (provided)
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
6
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2015.7
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2015 All Right Reserved.