Moore 36P Continuous Trace Recorder FEATURES & BENEFITS High resolution, four-color vacuum fluorescent display (VFD) delivers information with exceptional color and clarity Four disposable fiber-tipped pens deliver clear traces Up to 6 contact event inputs, up to 12 relay outputs, and up to 4 analog outputs offer real flexibility Easy front panel configuration simplifies set-up PCMCIA memory card drive affords convenient data storage Requires only 9.29" (236 mm) depth behind the panel DESCRIPTION The Moore 36P Strip Chart Recorder displays information on a crisp VFD and a four-color continuous trace printing system that uses disposable fiber tipped pens. Front panel configuration allows easy set-up, and a variety of input, output, and performance options providing extensive system flexibility. Moreover, its rugged steel case and die-cast door are designed to meet the rigors of industrial environments. The 36P employs a high resolution, four-color VFD with five 12 mm characters for process value, twenty 4 mm characters for text, and three 1 mm bar-graphs. It displays the measured value of each channel with its associated descriptor or scale, and provides bargraph indication of the three channels’ values. Data stored on a Type I PCMCIA data card may be formulated for analysis, presentation, storage, and archiving using standard spreadsheet packages. Stored data can include the recorder’s configuration, which can be saved to the data card for archiving or to transfer it to another recorder. A variety of math, timer, totalizer, and counter functions offer full integrating and counting capabilities. These options make it possible to handle even the most complex application-specific functions, such as environmental parameter monitoring or gas flow compensation. The Moore 36P Continuous Trace Recorder supports MODBUS® communications for integration with other devices. Inputs are fully universal with V, mV, TC, RTD and contact inputs, and can be used as contact inputs to trigger internal recorder actions. A dedicated 6 contact event input card is also available. Up to 12 relay outputs can be employed, and up to four analog outputs can be sent as a linearized current or voltage signal for retransmission to other instruments. Control Solutions - Recorders Die-cast front door and steel case ensure operation in harsh industrial environments The Moore 36P is completely configurable from the front panel via local pushbuttons and text prompts. This allows direct access to operator changes, and access to passwordprotected configurations. Americas +1 215 646 7400 ext. 6613 Asia Pacific +65 299 6051 Europe +44 1935 706262 41 SPECIFICATIONS Memory Configuration EEPROM ELECTRICAL Custom Linearization 1 table of 32 point pairs Power Requirements Line Power: 45 to 65 Hz; 90 to 264 Vac DC Power: 24/48 Vdc Consumption (max): 100 VA, 100W Fuse Type: None Interrupt Protection: 40 msec @ 75% instrument load ENVIRONMENTAL Control Solutions - Recorders Temperature Limits Operating: 0 to 50°C Storage: -20 to +70°C Humidity Limits Operation: 5% to 80% RH (non-condensing) Storage: 5% to 90% RH (non-condensing) Protection Door and Bezel: IP54 (similar to NEMA 3) Case Sleeve: IP31 (similar to NEMA 1) Shock/Vibration: IEC348, IEC873 recovers from 2G peak @ 10Hz to 150Hz EMC Electromagnetic Emissions: EN50081-2 Safety: To EN61010; Installation II; Pollution Category 2 Static: IEC801-2 level 4 to 15KV (air discharge, panel mounted, open door) Fast Transients: IEC801-3 (instrument within specification) IEC801-4 (automatic recovery from any error/ malfunctions) R.F. Immunity: IEC801-3 to 10V/m (level 3) + 1% on 0 to 100°C PROPERTIES Printing System Pen Type: Disposable fiber-tipped pens Pen Resolution: 0.15 mm Pen Colors: Ch. 1: blue; Ch. 2: red; Ch. 3: green; Ch. 4: violet; Annotator: black Pen Life: 1.2 km (channel pens); 106 dots (annotator) Update Rate: 8 Hz (system) Response Time: 1 second maximum Paper Transport Type: Stepper motor driving sprocket tube Chart Speeds: 0 to 36,000 mm/hr (user selectable) Chart Type: 100 mm calibrated width, 16 meter Z-fold Input to Paper Accuracy: 0.5% of span GENERAL PARAMETERS Inputs Maximum Number: Up to 4 inputs Types Thermocouple: B, C, D, E, G2, J, K, L, N, R, S, T, U, Ni/NiMo, Platinel II RTD: 2/3-wire resistance temperature detector (not channel 1 if any other channel is a thermocouple input); Pt100, Pt1000, Ni100, Ni1000 Vdc: 38mV; 150mV; 1V; 10V dc milliamps (mA): External shunt required Ohms: 0 to 150W, 0 to 600W, 0 to 6KW Contact Closure: Not channel 1 Minimum: 60 msec Type Mix: Freely configurable Noise Rejection (48 to 62 Hz) Common mode: >140dB (ch to ch and ch to gr) Series mode: >60dB Maximum Comm. Mode 250V continuous Maximum Series Mode 45mV @ lowest range; 12V peak @ highest range Isolation 300V RMS (dc to 65Hz; EN61010) (or dc ch to ch and ch to gr) Dielectric Strength 1350 Vac for 1 min (ch to gr) 2300 Vac for 1 min (ch to ch) Insulation Resistance >10MΩ @ 500Vdc Input Impedance 38mV, 150mV & 1V range: >10MΩ 10V range: 68.8KΩ Overload Protection 50V peak Open Circuit Detection + 57 nA maximum Recognition Time: 125 msec Minimum Break Resistance: 10MΩ Data Storage Format PCMCIA data card (Type I) 42 Moore Process Automation Solutions www.moore-solutions.com OPTIONS Outputs Relay Outputs: Up to 12 Ratings for Resistive Loads (derate for inductive loads) Switching Voltage: 250Vac, 30Vdc Switching Power: 500VA, 60W Break Current: 2A within referenced voltage & power limits Retransmission Outputs Configurable Output Ranges: 0-20mA; 4-20mA; 1-5 V; 0-10V Communications RS422/RS485 Gould Modicon MODBUS RTU ACCESSORIES Physical Panel (Bezel) Size: 5.7" x 5.7" (144 mm x 144 mm) Panel Cutout: 5.4" x 5.4" (138 mm x 138 mm) Depth Behind Panel: 9.29"/236 mm with terminal cover Panel Mounting: DIN43700; Vertical + 30° Weight: 7.75 lbs. (3.5 kg) Event Input Board Maximum Number Inputs: 6 discrete contact closures or 16 coded (using Binary codes on inputs 1-4, strobed @ input 5) Part number Description 4LA249550 4LA249551 4LA249552 4LA249553 4LA249554 GD201125 GD204080U050 IF247152U102 IF247152U104 IF247152U106 IF247152U107 LA207028U004 LA207028U006 4-Annotation Pens 4-Blue Pens, Ch.1 (top pen) 4-Red Pens, Ch.2 (third pen) 4-Green Pens, Ch.3 (sec. pen) 4-Violet Pens, Ch.4 (first pen) 36P,M Chart, 50 line, Z-fold 36P,M Chart, 50 line, Roll 36P,M—128K SRAM Card 36P,M—512K SRAM Card 36P,M—2 Meg SRAM Card 36P,M—4 Meg SRAM Card (4)-250 ohm shunts for 36V/P/M (6)-250 ohm shunts for 36V/P/M Transmitter Power Supply Outputs: 6 isolated 24Vdc Current: 20mA each output Permissible Load: 600Ω maximum INSTALLATION DRAWINGS Americas +1 215 646 7400 ext. 6613 Asia Pacific +65 299 6051 Europe +44 1935 706262 Control Solutions - Recorders Math Pack Number of Derived Channels:16 configurable Basic Functions: Off, const., add, subtract, multiply, divide, modulus Advanced Functions: (includes Basic) Sq rt, ch avg, DV group avg, rolling avg, ex, 10x, in, log10, rate-of-change, sample and hold, ch min, DV group latch min, DV group cont min, ch max, DV group latch max, DV group cont max, 3rd order polynominal, F°, relative humidity, mass flow: near; mass flow: sq rt; ZrO2 probe, high select, low select, switch, stopwatch, timestamp, O2 correction, percentile 43 MODEL NUMBER Chart Paper Recorder with Chart Annotation Power 1 90-264 Vac (Set for 120 Vac) 2 24/28 Vdc 3 90-264 Vac (Set for 220/240 Vac) Pens 1 1 Isolated Universal Input Channel 2 2 Isolated Universal Input Channels 3 3 Isolated Universal Input Channels 4 4 Isolated Universal Input Channels Chart Type and PCMCIA Drive Type 1 Z-fold and No Drive 2 Z-fold and Packed Data Storage Drive 3 Roll and No Drive 4 Roll and Packed Data Storage Drive Option Slot #1 N None 1 Relays-4NC 2 Relays-4NO 3 Relays-3 Form C 4 Retransmission-2 Outputs 5 Event Contacts-6 Inputs Option Slot #2 N None 1 Relays-4NC 2 Relays-4NO 3 Relays-3 Form C 4 Retransmission-2 Outputs Option Slot #3 N None 1 Relays-4NC 2 Relays-4NO 3 Relays-3 Form C Transmitter Supply (Not available with 24 Vdc Operating Voltage Option) N No Supply 1 3 Channel Supply 2 6 Channel Supply Math 1 Basic Math 2 Advanced 3 Advanced + 32pt Characterizer 4 Advanced + 20 Messages 5 Advanced + 32pt Characterizer + 20 Messages Advanced Functions N None 1 2 Totalizers 2 4 Totalizers 3 6 Totalizers 4 6 each Timers, Counters 5 6 each Timers, Counters, Totalizers Communications N None A RS 485 Modbus Reserved for Factory Use N Certifications 1 CE 2 CE & CSA 36P 1 Control Solutions - Recorders 36P 44 4 1 N N N N 1 N N N 1 Sample Model Number Moore Process Automation Solutions www.moore-solutions.com