© Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 ■ Overview Probe Applications Rod version Conductive liquids, slurries or solids Rod version with stilling well • Conductive liquids or slurries in nonconductive tanks • Non-conductive liquids in non-conductive tanks • Tanks with agitation or turbulent liquids • Liquids with a dielectric constant below 2 • Non-linear tanks, such as parabolic or spherical tanks • Interface measurements Cable version Non-conductive solids or liquids PFA coated cable version Conductive or sticky liquids, slurries, or solids Extended cable with rod version Long range conductive liquids, slurries or solids when level or interface measurements are required in the low area of the bin or tank 4 SITRANS LC500 is an inverse frequency shift capacitance level or interface transmitter for extreme and critical process conditions, such as oil and liquefied natural gas (LNG) as well as toxic and aggressive chemicals and vapors. ■ Configuration Installation ■ Benefits • Active-Shield technology so measurement is unaffected by material buildup in active shield section • Simple push-button calibration and integrated local display • Inverse frequency approach provides high resolution • 2-wire loop powered 4 to 20/20 to 4 mA measurement signal • Pre-detection alarm and full function diagnostics • High temperature and pressure resistant (optional) • Full-function diagnostics comply with NAMUR NE 43 • Easy calibration locally or via HART (using SIMATIC PDM software) Build up of material or condensation in active shield area does not affect switch operation. ■ Application SITRANS LC500’s advanced electronics provide one-step, push-button calibration and local display for easy on-site installation and setup. The unique mechanical probe design coupled with a high performance transmitter gives superior performance in toxic and aggressive chemicals, acids, caustics, adhesives, and in viscous conductive and non-conductive materials. The SMART 2-wire transmitter has HART communications for remote commissioning and inspection. • Key Applications: oil/water or foam/liquid interface measurement in separators or coalescers, cryogenic applications including C02 and liquefied natural gas (LNG), distillation/regeneration tanks with high temperatures 4/350 Siemens FI 01 · 2016 Mounting on non-linear vessels in non-conductive fluids using stilling well. SITRANS LC500 installation, dimensions in mm (inch) © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 ■ Technical specifications Design Input Measuring range 1 ... 3 300 pF Span Min. 3.3 pF Material • Wetted parts material - Standard rod • Probe insulation (rod) • Cable Output Solid-state switch • Output • Protection • Max. switching voltage • Max. load current • Voltage drop • Time delay (pre or post switching) Loop current Galvanically isolated Bipolar • 30 V (DC) • 30 V peak (AC) 82 mA < 1 V, typical at 50 mA 1 ... 60 s Probe diameter • Rod version • Cable version Active shield length • Minimum (rod version) 3.6 ... 22 mA/22 ... 3.6 mA (2-wire current loop) Accuracy (transmitter) Temperature stability 0.15 pF (0 pF) or < 0.25 % (typically < 0.1 %) of actual measured value, whichever is greater over the full temperature range Non-linearity and repeatability < 0.1 % of range and actual measured value respectively Accuracy Deviation < 0.1 % of measured value Probe length • Rod version • Cable version Process connection of probe • Threaded mounting Rated operating conditions1) Installation conditions • Location • Flange mounting Indoor/outdoor -40 ... +85 °C (-40 ... +185 • Installation category II • Pollution degree 4 °F)2) Medium conditions • Relative dielectric constant r Min. 1.5 • Minimum difference in dielectric constant for interface 5 • Process temperature Temperature rating of process seal is pressure dependent. See Pressure/Temperature curves on page 4/360. -50 ... +200 °C (-58 ... +392 °F) -200 ... +200 °C (-328 ... +392 °F) - Standard (PFA)3) - Cryogenic version4) 16 mm (0.63 inch) or 24 mm (0.95 inch) 9 mm (0.35 inch) with PFA jacket, 6 mm (0.24 inch) without PFA jacket 50 mm (1.97 inch), customer selectable (order number Y02) Max. 3.5 m (138 inch) with 16 mm rod, PFA Max. 5.5 m (216 inch) with 24 mm rod, PFA Max. 35 m (1 378 inch) NPT [(Taper), ANSI/ASME B1.20.1] R [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] ASME, EN 1092-1 Enclosure Ambient conditions • Ambient temperature (transmitter) 316L stainless steel PFA 316 stainless steel/ 316 stainless steel PFA • Process pressure Pressure rating of process seal is temperature dependent. See Pressure/Temperature curves on page 4/360. • Standard (PFA) -1 ... 150 bar g (2 175 psi g) Material Aluminum, epoxy-coated Cable inlet 2 x ½ inch NPT (2 x M20 x 1.5, IP68 adapter, optional) Degree of protection Type 4X/NEMA4X/IP65, IP68 Power supply 12 ... 33 V DC User Interface Display Local LCD, 4 digit, each 0 ... 9 and limited alpha characters Rotary function switch For selecting programmable menu items Push buttons Red +, blue -, used in conjunction with rotary switch for programming Features Measurement current signaling According to NAMUR NE 43, signal 3.8 ... 20.5 mA, fault 3.6 or 21 mA (22 mA) Safety • Inputs/outputs fully galvanically isolated • Polarity-insensitive current loop • Fully potted • Integrated safety barrier Primary variable (PV) out of limits, system failure in measurement circuit, deviation between A/D and D/A converter, check sum, watch dog and self-checking facility Positions 0 ... 9, A ... F Conforming to HART Communication Foundation (HCF) • Diagnostics with fault alarm when: • Function rotary switch • SMART communication Siemens FI 01 · 2016 4/351 4 © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 Certificates and approvals General Purpose CE, CSA, FM, RCM, KCC, EAC Non-incendive/Non-sparking • CSA/FM Class I, Div. 2, Groups A, B, C, D T4 ATEX II 3G 2D EEx nA [ib] IIC • T6 ... T4 T100 °C Dust Ignition Proof (Intrinsically Safe Probe Circuit) • Canada/USA • Europe • Brazil • Russia/Kazakhstan 4 Explosion Proof (Intrinsically Safe Probe Circuit) • Canada/USA CSA/FM Class II and III, Div. 1, Groups E, F, G ATEX II 1/2 GD EEx d [ia] T6 ... T1 T100 °C INMETRO Ex d [ia Ga] IIC T6 … T1 Gb Ex tb [ia Da] IIIC T100 °C Db -40 °C Ta +70 °C IP65/IP68 EAC Ex • Europe FM Class I, Div. 1, Groups A, B, C, D T4 ATEX II 1/2 GD EEx d [ia] IIC T6 ... T1 Overfill Protection AIB-Vincotte Marine Lloyds Register of Shipping, Categories ENV1, ENV2, ENV3, and ENV5, Bureau Veritas Other Pattern approval (AQSIQ, China), CRN 1) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves on page 4/360. 2) Thermal isolator is used if process connection temperature exceeds 85 °C (185 °F). 3) Not recommended for steam environments 4) Customers interested in a custom designed device should consult a local sales person. For more information, please visit http:// www.automation.siemens.com/aspa_app. SITRANS LC500 probe version Standard Extended Cable version with Rod Sensor Process connection types Threaded or welded flange Single piece flanged Threaded or welded flange Threaded Available as standard – Available as standard Flange Available as standard Available as standard Available as standard Available as standard Available as standard Available as standard Available as standard Available as standard Available as standard Rod length for PFA 16 mm version Min. 200 mm (7.87 inch) Max. 3 500 mm (137.80 inch) Min. 200 mm (7.87 inch) Max. 3 500 mm (137.80 inch) Min. 200 mm (7.87 inch) Max. 3 500 mm (137.80 inch) Rod length for PFA 24 mm version Min. 200 mm (7.87 inch) Max. 5 500 mm (216.54 inch) Min. 200 mm (7.87 inch) Max. 5 500 mm (216.54 inch) Min. 200 mm (7.87 inch) Max. 5 500 mm (216.54 inch) Cable length Min. 1 000 mm (39.37 inch) Max. 35 000 mm (1 377.95 inch) Min. 1 000 mm (39.37 inch) Max. 35 000 mm (1 377.95 inch) Min. 5 000 mm (196.85 inch)2) Max. 35 000 mm (1 377.95 inch)2) Maximum process pressure See Pressure/Temperature curves for specific probe type Process connection materials Stainless steel 316L Probe insulation PFA Length and Process parameters1) Maximum process temperature 1) 2) - See Pressure/Temperature curves for specific probe type Refers to total insertion length. See dimension drawing on page 4/368 for further explanation. Not available as standard. 4/352 Siemens FI 01 · 2016 5 bar g (73 psi g) 100 °C (212 °F) © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 Selection and Ordering data SITRANS LC500, Threaded or Welded Flange with Cable Sensor Inverse frequency shift capacitance level and interface transmitter for extreme and critical process conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Version1) Cable, 9 mm (0.35 inch) diameter, 316 stainless steel with PFA insulation, weighted Add Order code Y01 and plain text: "Insertion length ... mm" 1 000 ... 2 000 mm (39.37 ... 78.74 inch) 2 001 ... 4 000 mm (78.78 ... 157.48 inch) 4 001 ... 6 000 mm (157.52 ... 236.22 inch) 6 001 ... 8 000 mm (236.26 ... 314.96 inch) 8 001 ... 10 000 mm (315 ... 393.70 inch) Longer lengths possible to a max. of 35 000 mm (114.83 ft). Please contact local sales person for details. Cable, 6 mm (0.24 inch) diameter, 316L stainless steel, non-insulated, weighted (non-conductive media only) Add Order code Y01 and plain text: "Insertion length ... mm" 1 000 ... 2 000 mm (39.37 ... 78.74 inch)2) 2 001 ... 4 000 mm (78.78 ... 157.48 inch)2)3) 4 001 ... 6 000 mm (157.52 ... 236.22 inch)2)3) 6 001 ... 8 000 mm (236.26 ... 314.96 inch)2)3) 8 001 ... 10 000 mm (315 ... 393.70 inch)2)3) Cable lengths up to 25 000 mm (984.25 inch) are possible for non-conductive media. Cable lengths up to 15 000 mm (590.55 inch) are possible for conductive media. Please contact a local sales person for details. Process connection (316L stainless steel) Threaded connection 1½" NPT [(Taper), ANSI/ASME B1.20.1] R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1¼" NPT [(Taper), ANSI/ASME B1.20.1] G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] Welded flange, raised face 1½", ASME, 150 Ib 1½", ASME, 300 Ib 1½", ASME, 600 Ib 2", ASME, 150 Ib 2", ASME, 300 Ib 2", ASME, 600 Ib 3", ASME, 150 Ib3) 3", ASME, 300 Ib3) 3", ASME, 600 Ib3) 4", ASME, 150 Ib3) 4", ASME, 300 Ib3) 4", ASME, 600 Ib3) 6", ASME, 150 Ib3) 6", ASME, 300 Ib3) 6", ASME, 600 Ib3) Article No. 7ML551377 7 77 - 77 77 0E 1E 2E 3E 4E 0F 1F 2F 3F 4F Article No. 7ML55137 7 7 77 - 77 7 7 1 2 4 6 1 2 4 A B A B 0 1 1) A minimum span of 3 pF must be maintained Available with non-conductive media only Custom shipping methods required. Contact factory for more details. 4) Available in PFA insulated version only 2) 3) C0 F0 K0 L0 B1 B2 B3 C1 C2 C3 D1 D2 D3 E1 E2 E3 F1 F2 F3 Welded flange, Type A flat faced DN 40, PN 16 DN 40, PN 40 DN 50, PN 16 DN 50, PN 40 DN 80, PN 16 DN 80, PN 403) DN 100, PN 163) DN 100, PN 403) DN 125, PN 163) DN 125, PN 403) (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5, or EN 1092-1 standard.) Sanitary, hastelloy, duplex or other custom process connections available. Please contact a local sales person for details. Selection and Ordering data SITRANS LC500, Threaded or Welded Flange with Cable Sensor Inverse frequency shift capacitance level and interface transmitter for extreme and critical process conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Approvals General Purpose: CE, CSA, FM, RCM CSA / FM Class I, Div. 2, Groups A, B, C, D CSA / FM Class II, III, Div. 1, Groups E, F, G T4 ATEX II 3G 2D EEx nA [ib] IIC T6 ... T4 T 100 °C ATEX II 1/2 GD EEx d [ia] IIC T6 ... T1 T 100 °C FM Class I, Div. 1, Groups A, B, C, D, T4 Enclosure/Cable inlet Aluminum epoxy coated 2 x ½" NPT, IP68 2 x M20 x 1.5 (IP68, adapter) Stainless steel Please contact a local sales person for details. Options No additional options With mounting eye4) Thermal isolator Without thermal isolator Isolator, only for use when temperature range is outside of -40 ... +85 °C (-40 ... +185 °F), explosion proof approval -40 ... +70 °C (-40 ... +158 °F) Electronic output No transmitter supplied 2-wire loop current 4 ... 20 mA (transmitter MSP 2002-2 _3300 pF) Customers interested in a custom designed device should consult a local sales person. For more information, please visit http://www.automation.siemens.com/aspa_app. Order code Selection and Ordering data Further designs Please add "-Z" to Article No. and specify Order code(s). Insertion length, specify in plain text: Y01: ... mm Y01 Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Measuring-point number/identification (max. 27 characters) specify in plain text Y15 Manufacturer's test certificate: M to DIN 55350, Part 18 and to ISO 9000 C11 Inspection Certificate Type 3.1 per EN 10204 C12 Operating Instructions See page 4/359 Accessories See page 4/359 K4 K5 L4 L5 M4 M5 N4 N5 P4 P5 Siemens FI 01 · 2016 4/353 © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 4 Selection and Ordering data SITRANS LC500, Threaded or Welded Flange, with Rod Sensor Inverse frequency shift capacitance level and interface transmitter for extreme and critical process conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Version Rod, 16 mm (0.63 inch), PFA insulated Add Order code Y01 and Y02 and plain text: "Insertion length ... mm and active shield length ... mm" 200 ... 1 000 mm (7.87 ... 39.37 inch)1) 1 001 ... 2 000 mm (39.41 ... 78.74 inch) 2 001 ... 3 000 mm (78.78 ... 118.11 inch)2) 3 001 ... 3 500 mm (118.15 ... 137.80 inch)2) Rod, 16 mm (0.63 inch), PFA insulated with 35 mm (1.38 inch) stilling well in 316L stainless steel Add Order code Y01 and Y02 and plain text: "Insertion length ... mm and active shield length ... mm" 200 ... 1 000 mm (7.87 ... 39.37 inch)1)3) 1 001 ... 2 000 mm (39.41 ... 78.74 inch)3) 2 001 ... 3 000 mm (78.78 ... 118.11 inch)2)3) 3 001 ... 3 500 mm (118.15 ... 137.80 inch)2)3) Rod, 24 mm (0.94 inch), PFA insulated Add Order code Y01 and Y02 and plain text: "Insertion length ... mm and active shield length ... mm" 200 ... 1 000 mm (7.87 ... 39.37 inch)4) 1 001 ... 2 000 mm (39.41 ... 78.74 inch)4) 2 001 ... 3 000 mm (78.78 ... 118.11 inch)2)4) 3 001 ... 4 000 mm (118.15 ... 157.48 inch)2)4) 4 001 ... 5 000 mm (173.26 ... 196.88 inch)2)4) 5 001 ... 5 500 mm (196.89 ... 216.54 inch)2)4) Rod, 24 mm (0.94 inch), PFA insulated with 48 mm (1.89 inch) stilling well in 316L stainless steel Add Order code Y01 and Y02 and plain text: "Insertion length ... mm and active shield length ... mm" 200 ... 1 000 mm (7.87 ... 39.37 inch)5) 1 001 ... 2 000 mm (39.41 ... 78.74 inch)5) 2 001 ... 3 000 mm (78.78 ... 118.11 inch)2)5) 3 001 ... 4 000 mm (118.15 ... 157.48 inch)2)5) 4 001 ... 5 000 mm (173.26 ... 196.88 inch)2)5) 5 001 ... 5 500 mm (196.89 ... 216.54 inch)2)5) Bent probes also available. Please contact a local sales person for details. Process connection (316L stainless steel) Threaded connection ¾" NPT [(Taper), ANSI/ASME B1.20.1] 1" NPT [(Taper), ANSI/ASME B1.20.1] 1½" NPT [(Taper), ANSI/ASME B1.20.1] 2" NPT [(Taper), ANSI/ASME B1.20.1] R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] R 2" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1¼" NPT [(Taper), ANSI/ASME B1.20.1] G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] G 2" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] Welded flange, raised face 1½", ASME, 150 Ib 1½", ASME, 300 Ib 1½", ASME, 600 Ib 2", ASME, 150 Ib 2", ASME, 300 Ib 2", ASME, 600 Ib 3", ASME, 150 Ib2) 3", ASME, 300 Ib2) 3", ASME, 600 Ib2) 4/354 Siemens FI 01 · 2016 Article No. 7ML551577 7 77 - 77 77 0A 1A 2A 3A 0B 1B 2B 3B 0C 1C 2C 3C 4C 5C Selection and Ordering data SITRANS LC500, Threaded or Welded Flange, with Rod Sensor Inverse frequency shift capacitance level and interface transmitter for extreme and critical process conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. 4", ASME, 150 Ib2) 4", ASME, 300 Ib2) 4", ASME, 600 Ib2) 6", ASME, 150 Ib2) 6", ASME, 300 Ib2) 6", ASME, 600 Ib2) Welded flange, Type A flat faced DN 40, PN 16 DN 40, PN 40 DN 50, PN 16 DN 50, PN 40 DN 80, PN 16 DN 80, PN 402) DN 100, PN 162) DN 100, PN 402) DN 125, PN 162) DN 125, PN 402) (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5, or EN 1092-1 standard.) Sanitary, hastelloy, duplex or other custom process connections available. Please contact a local sales person for details. Approvals General Purpose: CE, CSA, FM, RCM CSA / FM Class I, Div. 2, Groups A, B, C, D CSA / FM Class II, III, Div. 1, Groups E, F, G T4 ATEX II 3G 2D EEx nA [ib] IIC T6 ... T4 T 100 °C ATEX II 1/2 GD EEx d [ia] IIC T6 ... T1 T 100 °C FM Class I, Div. 1, Groups A, B, C, D, T4 Enclosure/Cable inlet Aluminum epoxy coated 2 x ½" NPT, IP68 2 x M20 x1.5 (IP68, adapter) Article No. 7ML55157 7 7 77 - 77 7 7 E1 E2 E3 F1 F2 F3 K4 K5 L4 L5 M4 M5 N4 N5 P4 P5 1 2 4 6 1 2 Stainless steel 0D 1D 2D 3D 4D 5D A0 B0 C0 D0 E0 F0 J0 K0 N0 P0 R0 S0 Please contact a local sales person for details. Options No additional options Thermal isolator/remote version Without thermal isolator or remote electronics Thermal isolator, only for use when temperature range is outside of -40 ... +85 °C (-40 ... +185 °F), explosion proof approval -40 ... +70 °C (-40 ... +158 °F) Remote electronics with mounting bracket and cable6) • Length: 2 m (79 inch) • Length: 3 m (118 inch) • Length: 4 m (158 inch) • Length: 5 m (197 inch) Electronic output No transmitter supplied 2-wire loop current 4 ... 20 mA (transmitter MSP 2002-2 _3300 pF) 1) 2) 3) T0 4) 5) B1 B2 B3 C1 C2 C3 D1 D2 D3 6) A A B C D E F 0 1 A minimum span of 3 pF must be maintained Custom shipping methods required. Contact factory for more details. Available with process connection 1½" or larger Available with process connection 1" or larger Available with process connection 2 " or larger Available with approval option 1 only Customers interested in a custom designed device should consult a local sales person. For more information, please visit http://www.automation.siemens.com/aspa_app. © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 Selection and Ordering data Order code Further designs Please add "-Z" to Article No. and specify Order code(s). Insertion length, specify in plain text: Y01: ... mm Y01 Active shield length, specify in plain text [min. length is 50 mm (2 inch), max. length is 3 350 mm (131.89 inch)]: Y02: ... mm Y02 Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Measuring-point number/identification (max. 27 characters) specify in plain text Y15 Manufacturer's test certificate: M to DIN 55350, Part 18 and to ISO 9000 C11 Inspection Certificate Type 3.1 per EN 10204 C12 Manufacturing Test Report (Electrode Test) C18 Operating Instructions See page 4/359 Accessories See page 4/359 4 Siemens FI 01 · 2016 4/355 © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 4 Selection and Ordering data SITRANS LC500, Single Piece Flanged with Rod Sensor Inverse frequency shift capacitance level and interface transmitter for extreme and critical process conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Version Rod, 16 mm (0.63 inch), PFA insulated Add Order code Y01 and Y02 and plain text: "Insertion length ... mm and active shield length ... mm" 250 ... 1 000 mm (9.84 ... 39.37 inch)1) 1 001 ... 2 000 mm (39.41 ... 78.74 inch) 2 001 ... 3 000 mm (78.78 ... 118.11 inch)2) 3 001 ... 3 500 mm (118.15 ... 137.80 inch)2) Rod, 16 mm (0.63 inch), PFA insulated with 35 mm (1.34 inch) stilling well in 316L stainless steel Add Order code Y01 and Y02 and plain text: "Insertion length ... mm and active shield length ... mm" 250 ... 1 000 mm (9.84 ... 39.37 inch) 1 001 ... 2 000 mm (39.41 ... 78.74 inch) 2 001 ... 3 000 mm (78.78 ... 118.11 inch)2) 3 001 ... 3 500 mm (118.15 ... 137.80 inch)2) Rod, 24 mm (0.94 inch), PFA insulated Add Order code Y01 and Y02 and plain text: "Insertion length ... mm and active shield length ... mm" 250 ... 1 000 mm (9.84 ... 39.37 inch) 1 001 ... 2 000 mm (39.41 ... 78.74 inch) 2 001 ... 3 000 mm (78.78 ... 118.11 inch)2) 3 001 ... 4 000 mm (118.15 ... 157.48 inch)2) 4 001 ... 5 000 mm (173.26 ... 196.88 inch)2) 5 001 ... 5 500 mm (196.89 ... 216.54 inch)2) Rod, 24 mm (0.94 inch), PFA insulated with 48 mm (1.89 inch) stilling well in 316L stainless steel Add Order code Y01 and Y02 and plain text: "Insertion length ... mm and active shield length ... mm" 250 ... 1 000 mm (9.84 ... 39.37 inch) 1 001 ... 2 000 mm (39.41 ... 78.74 inch)2)3) 2 001 ... 3 000 mm (78.78 ... 118.11 inch)2)3) 3 001 ... 4 000 mm (118.15 ... 157.48 inch)2)3) 4 001 ... 5 000 mm (173.26 ... 196.88 inch)2)3) 5 001 ... 5 500 mm (196.89 ... 216.54 inch)2)3) Bent probes also available. Please contact a local sales person for details. Process connection (316L stainless steel) Single piece flange, raised face 1½", ASME, 150 Ib 1½", ASME, 300 Ib 1½", ASME, 600 Ib 2", ASME, 150 Ib 2", ASME, 300 Ib 2", ASME, 600 Ib 3", ASME, 150 Ib2) 3", ASME, 300 Ib2) 3", ASME, 600 Ib2) 4", ASME, 150 Ib2) 4", ASME, 300 Ib2) 4", ASME, 600 Ib2) 6", ASME, 150 Ib2) 6", ASME, 300 Ib2) 6", ASME, 600 Ib2) 4/356 Siemens FI 01 · 2016 Article No. 7ML551777 7 77 - 7777 0A 1A 2A 3A Selection and Ordering data SITRANS LC500, Single Piece Flanged with Rod Sensor Inverse frequency shift capacitance level and interface transmitter for extreme and critical process conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Single piece flange, Type B1 raised face DN 40, PN 16 DN 40, PN 40 DN 50, PN 16 DN 50, PN 40 DN 80, PN 16 DN 80, PN 402) DN 100, PN 162) DN 100, PN 402) DN 125, PN 162) DN 125, PN 402) Single piece flange with PTFE flange facing (applicable with versions 0A ... 3A and 0C ... 5C)4) 1½" ASME, 150 Ib 0B 1B 2B 3B 0C 1C 2C 3C 4C 5C 0D 1D 2D 3D 4D 5D B1 B2 B3 C1 C2 C3 D1 D2 D3 E1 E2 E3 F1 F2 F3 1½", ASME, 300 Ib 1½", ASME, 600 Ib 2", ASME, 150 Ib 2", ASME, 300 Ib 2", ASME, 600 Ib 3", ASME, 150 Ib2) 3", ASME, 300 Ib2) 3", ASME, 600 Ib2) 4", ASME, 150 Ib2) 4", ASME, 300 Ib2) 4", ASME, 600 Ib2) 6", ASME, 150 Ib2) 6", ASME, 300 Ib2) 6", ASME, 600 Ib2) Single piece flange with PTFE flange facing (applicable with versions 0A ... 3A, 0C ... 5C)4) DN 40, PN 16 DN 40, PN 40 DN 50, PN 16 DN 50, PN 40 DN 80, PN 16 DN 80, PN 402) DN 100, PN 162) DN 100, PN 402) DN 125, PN 162) DN 125, PN 402) (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5, or EN 1092-1 standard.) Sanitary, hastelloy, duplex or other custom process connections available. Please contact a local sales person for details. Article No. 7ML5517777 77 - 7777 K4 K5 L4 L5 M4 M5 N4 N5 P4 P5 B4 B5 B6 C4 C5 C6 D4 D5 D6 E4 E5 E6 F4 F5 F6 K6 K7 L6 L7 M6 M7 N6 N7 P6 P7 © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 Selection and Ordering data SITRANS LC500, Single Piece Flanged with Rod Sensor Inverse frequency shift capacitance level and interface transmitter for extreme and critical process conditions, such as oil and liquid gas, toxic and aggressive chemicals and vapours. Approvals General Purpose: CE, CSA, FM, RCM CSA / FM Class I, Div. 2, Groups A, B, C, D CSA / FM Class II, III, Div. 1, Groups E, F, G T4 ATEX II 3G 2D EEx nA [ib] IIC T6 ... T4 T 100 °C ATEX II 1/2 GD EEx d [ia] IIC T6 ... T1 T 100 °C FM Class I, Div. 1, Groups A, B, C, D, T4 Enclosure/Cable inlet Aluminum epoxy coated 2 x ½" NPT, IP68 2 x M20 x 1.5 (IP68, adapter) Stainless steel Please contact a local sales person for details. Options None Thermal isolator/remote version Without thermal isolator Isolator, only for use when temperature range is outside of -40 ... +85 °C (-40 ... +185 °F), explosion proof approval -40 ... +70 °C (-40 ... +158 °F) Remote electronics with mounting bracket and cable5) • Length: 2 m (79 inch) • Length: 3 m (118 inch) • Length: 4 m (158 inch) • Length: 5 m (197 inch) Electronic output No transmitter supplied 2-wire loop current 4 ... 20 mA (transmitter MSP 2002-2 _3300 pF) Article No. 7ML551777 7 77 - 7777 1 2 4 6 1 2 Order code Selection and Ordering data Further designs Please add "-Z" to Article No. and specify Order code(s). Insertion length, specify in plain text: Y01: ... mm Y01 Active shield length, specify in plain text [min. length is 50 mm (2 inch), max. length is 3 350 mm (131.89 inch)]: Y02: ... mm Y02 Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Measuring-point number/identification (max. 27 characters) specify in plain text Y15 Manufacturer's test certificate: M to DIN 55350, Part 18 and to ISO 9000 C11 Inspection Certificate Type 3.1 per EN 10204 C12 Manufacturing Test Report (Electrode Test) C18 Operating Instructions See page 4/359 Accessories See page 4/359 A 1) A minimum span of 3 pF must be maintained 2) Custom shipping methods required. Contact factory for more details. 3) Available with process connection 2" or larger, and only available with process connection options C1 ... F3, L4 ... P5 4) Not available with versions 0E and 0F 5) Available with approval option 1 only A B C D E F 0 1 Customers interested in a custom designed device should consult a local sales person. For more information, please visit http://www.automation.siemens.com/aspa_app. Siemens FI 01 · 2016 4/357 4 © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 4 Selection and Ordering data SITRANS LC500, Extended Cable version with Rod Sensor, threaded connection or welded flange1) Inverse frequency shift capacitance level and interface transmitter for short range continuous measurement in large storage vessels. Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Version2) Rod, 16 mm (0.63 inch), PFA insulated and 316L stainless steel flexible extension tube Total insertion length: Add Order code Y01 and plain text: "Total insertion length ... mm and Y02 and plain text: Active shield length ... mm"3)4) • 5 000 ... 10 000 mm (196.85 ... 393.70 inch)1) • 10 001 ... 15 000 mm (393.74 ... 590.55 inch)1) • 15 001 ... 20 000 mm (590.59 ... 787.40 inch)1) • 20 001 ... 25 000 mm (787.44 ... 984.25 inch)1) • 25 001 ... 30 000 mm (984.29 ... 1181.10 inch)1) • 30 001 ... 35 000 mm (1 181.14 ... 1 377.95 inch)1) Rod, 24 mm (0.94 inch), PFA insulated and 316L stainless steel flexible extension tube Total insertion length: Add Order code Y01 and plain text: "Total insertion length ... mm and Y02 and plain text: Active shield length ... mm"3)4) • 5 000 ... 10 000 mm (196.85 ... 393.70 inch)1) • 10 001 ... 15 000 mm (393.74 ... 590.55 inch)1) • 15 001 ... 20 000 mm (590.59 ... 787.40 inch)1) • 20 001 ... 25 000 mm (787.44 ... 984.25 inch)1) • 25 001 ... 30 000 mm (984.29 ... 1 181.10 inch)1) • 30 001 ... 35 000 mm (1 181.14 ... 1 377.95 inch)1) Process connection (316L stainless steel) Threaded connection 2" NPT [(Taper), ANSI/ASME B1.20.1] R 2" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G 2" [(BSPP), EN ISO 228-1/PF (JIS-P) JIS B 0202] Welded flange, raised face 2", ASME, 150 Ib 2", ASME, 300 Ib 3", ASME, 150 Ib1) 3", ASME, 300 Ib1) 4", ASME, 150 Ib1) 4", ASME, 300 Ib1) 6", ASME, 150 Ib1) 6", ASME, 300 Ib1) Welded flange, Type A flat faced DN 50, PN 16 DN 50, PN 40 DN 80, PN 16 DN 80, PN 401) DN 100, PN 161) DN 100, PN 401) DN 125, PN 161) DN 125, PN 401) (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5, or EN 1092-1 standard.) Sanitary, hastelloy, duplex or other custom process connections available. Please contact a local sales person for details. Approvals General Purpose: CE, CSA, FM, RCM CSA / FM Class I, Div. 2, Groups A, B, C, D CSA / FM Class II, III, Div. 1, Groups E, F, G T4 ATEX II 3G 2D EEx nA [ib] IIC T6 ... T4 T 100 °C ATEX II 1/2 GD EEx d [ia] IIC T6 ... T1 T 100 °C FM Class I, Div. 1, Groups A, B, C, D T4 4/358 Siemens FI 01 · 2016 Article No. 7ML55237 7 7 77 - 77 7 7 Selection and Ordering data SITRANS LC500, Extended Cable version with Rod Sensor, threaded connection or welded flange1) Inverse frequency shift capacitance level and interface transmitter for short range continuous measurement in large storage vessels. Enclosure/Cable inlet Aluminum epoxy coated 2 x ½" NPT, IP68 2 x M20 x 1.5 (IP68, adapter) Stainless steel Please contact a local sales person for details. Options No additional options With mounting eye Thermal isolator Without thermal isolator Isolator, only for use when temperature range is outside of -40 ... +85 °C (-40 ... +185 °F), explosion proof approval -40 ... +70 °C (-40 ... +158 °F) Electronic output No transmitter supplied 2-wire loop current 4 ... 20 mA (transmitter MSP 2002-2 _3300 pF) 0A 1A 2A 3A 4A 5A 0B 1B 2B 3B 4B 5B Article No. 7ML55237 7 7 77 - 77 7 7 1 2 A B 1) Custom shipping methods required. Contact factory for more details. 2) A minimum span of 3 pF must be maintained. 3) See dimension drawings on page 4/368 for further explanation of Y01. 4) Inactive length is equal to the flexible extension plus transition. See dimension drawings on page 4/368 for further explanation of Y02. A B 0 1 Customers interested in a custom designed device should consult a local sales person. For more information, please visit http://www.automation.siemens.com/aspa_app. A0 B0 D0 C1 C2 D1 D2 E1 E2 F1 F2 L4 L5 M4 M5 N4 N5 P4 P5 1 2 4 6 © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 Selection and Ordering data Order code Article No. Selection and Ordering data Further designs Accessories Please add "-Z" to Article No. and specify Order code(s). General Purpose Y01 1/2" NPT General Purpose Cable Entry IP68/IP69K NEMA6, -40 ... +100 °C (-40 ... +212 °F), cable size 6 ... 12 mm (0.236 ... 0.472 inch) 7ML1830-1JA Insertion length, specify in plain text: Y01: to mm (Includes measuring range plus cable extension) see dimensional information on page 4/368 Y02 M20 x 1.5 General Purpose Cable Entry IP68/IP69K NEMA6, -40 ... +100 °C (-40 ... +212 °F), cable size 7 ... 12 mm (0.275 ... 0.472 inch) 7ML1830-1JC Active shield/cable extension length, specify in plain text [min. length is 50 mm (2 inch), max. length is 5 500 mm (216.54 inch)]: Y02: to mm (see dimensional information on page 4/368) Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Measuring-point number/identification (max. 27 characters) specify in plain text Y15 Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000 C11 Inspection Certificate Type 3.1 per EN 10204 C12 Operating Instructions Article No. English 7ML1998-5GE04 German 7ML1998-5GE33 Hazardous Locations 1/2" NPT EMC rated Cable Gland: Dust Ignition Proof, Flameproof Exd, and Increased Safety ATEX II 2 GD ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22, and in Gas Groups IIA, IIB and IIC) -60 ... +80 °C IP66, IP67, IP68, NEMA4X, cable sizes 5.5 ... 12 mm (0.216 ... 0.472 inch) 7ML1830-1JB M20 EMC rated Cable Gland: Dust Ignition Proof, Flameproof Exd, and Increased Safety ATEX II 2 GD ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22, and in Gas Groups IIA, IIB and IIC) -60 ... +80 °C IP66, IP67, IP68, NEMA4X, cable sizes 5.5 ... 12 mm (0.216 ... 0.472 inch) 7ML1830-1JD Note: The Operating Instructions should be ordered as a separate line item on the order. All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation Transmitter, MSP 2002-1, 330 PF1) 7ML1830-1JP Transmitter, MSP 2002-2, 3 300 PF1) 7ML1830-1JQ Transmitter, MSP 2002-3, 6 600 PF (used with conductive fluids and probe lengths > 10 000 mm)1) 7ML1830-1JR This device is shipped with the Siemens Level and Weighing manual DVD containing the ATEX Quick Start and Operating Instructions library. SITRANS RD100, loop powered display see Chapter 7 7ML5741-... SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 7ML5740-... SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion see Chapter 7 7ML5744-... SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 7ML5750-... For applicable back up point level switch see point level measurement section 1) Transmitters not suitable for Intrinsically Safe application (ATEX II 1G EEx ia IIC T4 or CSA/FM Class I Div. 1 Groups A, B, C and D) Customers interested in a custom designed device should consult local sales person. For more information, please visit http://www.automation.siemens.com/aspa_app. Siemens FI 01 · 2016 4/359 4 © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 ■ Characteristic curves Pressure/temperature curve LC500 cable probes threaded process connections (7ML5513) Permitted operating pressures P 30 bar (435 psi) 20 bar (290 psi) 10 bar (145 psi) Atmospheric 4 -40 ºF 14 ºF (-40 ºC) (-10 ºC) -1 bar (-14.5 psi) -150 ºC (-238 ºF) -100 ºC -50 ºC (-148 ºF) (-58 ºF) 100 ºF (38 ºC) 0 ºC RT 50 ºC (32 ºF) (122 ºF) -29 ºC (-20 ºF) Example: permitted operating pressure = 10 bar (145 psi) at 75 °C SITRANS LC500 process pressure/temperature derating curves (7ML5513) 4/360 Siemens FI 01 · 2016 200 ºF (93 ºC) 100 ºC (212 ºF) 300 ºF (149 ºC) 150 ºC (302 ºF) 400 ºF (204 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (482 ºF) Permitted operating temperature T © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 Pressure/temperature curve LC500 PFA rod probes Threaded process connections (7ML5515) Permitted operating pressures P 150 bar (2.175 psi) 140 bar (2.030 psi) 130 bar (1.885 psi) 4 120 bar (1.740 psi) 110 bar (1.595 psi) 100 bar (1.450 psi) 90 bar (1.305 psi) 80 bar (1.160 psi) 70 bar (1.015 psi) 60 bar (870 psi) 50 bar (725 psi) 40 bar (580 psi) 30 bar (435 psi) 20 bar (290 psi) Atmospheric 10 bar (145 psi) -40 ºF 14 ºF (-40 ºC) (-10 ºC) -1 bar (-14.5 psi) -150 ºC (-238 ºF) -100 ºC -50 ºC (-148 ºF) (-58 ºF) 100 ºF (38 ºC) 0 ºC RT 50 ºC (32 ºF) (122 ºF) -29 ºC (-20 ºF) 200 ºF (93 ºC) 100 ºC (212 ºF) 300 ºF (149 ºC) 150 ºC (302 ºF) 400 ºF (204 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (482 ºF) Permitted operating temperature T SITRANS LC500 process pressure/temperature derating curves (7ML5515) Siemens FI 01 · 2016 4/361 © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 Pressure/temperature curve LC500 cable probes ASME flanged process connections (7ML5513) Permitted operating pressures P 20 bar (290 psi) 10 bar (145 psi) ASME 150 lb1) Atmospheric -40 ºF 14 ºF (-40 ºC) (-10 ºC) 4 -1 bar (-14.5 psi) -150 ºC (-238 ºF) -100 ºC -50 ºC (-148 ºF) (-58 ºF) 100 ºF (38 ºC) 0 ºC RT 50 ºC (32 ºF) (122 ºF) 200 ºF (93 ºC) 100 ºC (212 ºF) 300 ºF (149 ºC) 150 ºC (302 ºF) -29 ºC (-20 ºF) 1) The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC500 process pressure/temperature derating curves (7ML5513) 4/362 Siemens FI 01 · 2016 400 ºF (204 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (482 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC 400 ºC (662 ºF) (752 ºF) Permitted operating temperature T © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 Pressure/temperature curve LC500 PFA rod probes ASME flanged process connections (7ML5515 and 7ML5517) Permitted operating pressures P 150 bar (2.175 psi) 140 bar (2.030 psi) 130 bar (1.885 psi) 4 120 bar (1.740 psi) 110 bar (1.595 psi) 100 bar (1.450 psi) 90 bar (1.305 psi) 80 bar (1.160 psi) 70 bar (1.015 psi) 60 bar (870 psi) ASME 600 lb1) 50 bar (725 psi) 40 bar (580 psi) 30 bar (435 psi) ASME 300 lb1) 20 bar (290 psi) Atmospheric -40 ºF 14 ºF (-40 ºC)(-10 ºC) -1 bar (-14.5 psi) -150 ºC (-238 ºF) ASME 150 lb1) 10 bar (145 psi) -100 ºC -50 ºC (-148 ºF) (-58 ºF) 100 ºF (38 ºC) 0 ºC RT 50 ºC (32 ºF) (122 ºF) 200 ºF (93 ºC) 100 ºC (212 ºF) 300 ºF (149 ºC) 150 ºC (302 ºF) -29 ºC (-20 ºF) 1) 400 ºF (204 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (482 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC 400 ºC (662 ºF) (752 ºF) Permitted operating temperature T The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC500 process pressure/temperature derating curves (7ML5515 and 7ML5517) Siemens FI 01 · 2016 4/363 © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 Pressure/temperature curve LC500 cable probes EN flanged process connections (7ML5513) Permitted operating pressures P 20 bar (290 psi) 10 bar (145 psi) PN 161) Atmospheric -40 ºF 14 ºF (-40 ºC) (-10 ºC) 4 -1 bar (-14.5 psi) -150 ºC (-238 ºF) -100 ºC -50 ºC (-148 ºF) (-58 ºF) 100 ºF (38 ºC) 0 ºC RT 50 ºC (32 ºF) (122 ºF) 200 ºF (93 ºC) 100 ºC (212 ºF) 300 ºF (149 ºC) 150 ºC (302 ºF) -29 ºC (-20 ºF) 1) The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC500 process pressure/temperature derating curves (7ML5513) 4/364 Siemens FI 01 · 2016 400 ºF (204 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (482 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC 400 ºC (662 ºF) (752 ºF) Permitted operating temperature T © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 Pressure/temperature curve LC500 PFA rod probes EN flanged process connections (7ML5515 and 7ML5517) Permitted operating pressures P 150 bar (2.175 psi) 140 bar (2.030 psi) 130 bar (1.885 psi) 4 120 bar (1.740 psi) 110 bar (1.595 psi) 100 bar (1.450 psi) 90 bar (1.305 psi) 80 bar (1.160 psi) 70 bar (1.015 psi) 60 bar (870 psi) 50 bar (725 psi) 40 bar (580 psi) 30 bar (435 psi) PN 401) 20 bar (290 psi) Atmospheric 10 bar (145 psi) -40 ºF 14 ºF (-40 ºC)(-10 ºC) -1 bar (-14.5 psi) -150 ºC (-238 ºF) -100 ºC -50 ºC (-148 ºF) (-58 ºF) PN 161) 100 ºF (38 ºC) 0 ºC RT 50 ºC (32 ºF) (122 ºF) 200 ºF (93 ºC) 100 ºC (212 ºF) 300 ºF (149 ºC) 150 ºC (302 ºF) -29 ºC (-20 ºF) 1) 400 ºF (204 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (482 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC 400 ºC (662 ºF) (752 ºF) Permitted operating temperature T The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC500 process pressure/temperature derating curves (7ML5515 and 7ML5517) Siemens FI 01 · 2016 4/365 © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 Pressure/temperature curve LC500 single piece flanged rod probes with PTFE facing EN flanged process connections (7ML5517) Permitted operating pressures P 80 bar (1.160 psi) 70 bar (1.015 psi) 60 bar (870 psi) 4 50 bar (725 psi) 40 bar (580 psi) 30 bar (435 psi) PN 401) 20 bar (290 psi) -40 ºF 14 ºF 100 ºF (-40 ºC) (-10 ºC) (38 ºC) -1 bar (-14.5 psi) -150 ºC (-238 ºF) PN 161) 10 bar (145 psi) Atmospheric -100 ºC -50 ºC (-148 ºF) (-58 ºF) 0 ºC RT 50 ºC (32 ºF) (122 ºF) 200 ºF (93 ºC) 100 ºC (212 ºF) 300 ºF (149 ºC) 150 ºC (302 ºF) -29 ºC (-20 ºF) 1) The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC500 process pressure/temperature derating curves (7ML5517) 4/366 Siemens FI 01 · 2016 400 ºF (204 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (482 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC 400 ºC (662 ºF) (752 ºF) Permitted operating temperature T © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 Pressure/temperature curve LC500 single piece flanged rod probes with PTFE facing ASME flanged process connections (7ML5517) Permitted operating pressures P 80 bar (1.160 psi) 70 bar (1.015 psi) 60 bar (870 psi) ASME 600 lb1) 50 bar (725 psi) 40 bar (580 psi) 30 bar (435 psi) ASME 300 lb1) 20 bar (290 psi) Atmospheric -40 ºF 14 ºF (-40 ºC) (-10 ºC) -1 bar (-14.5 psi) -150 ºC (-238 ºF) ASME 150 lb1) 10 bar (145 psi) -100 ºC -50 ºC (-148 ºF) (-58 ºF) 100 ºF (38 ºC) 0 ºC RT 50 ºC (32 ºF) (122 ºF) 200 ºF (93 ºC) 100 ºC (212 ºF) 300 ºF (149 ºC) 150 ºC (302 ºF) -29 ºC (-20 ºF) 1) 400 ºF (204 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (482 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC 400 ºC (662 ºF) (752 ºF) Permitted operating temperature T The curve denotes the minimum allowable flange class for the shaded area below. SITRANS LC500 process pressure/temperature derating curves (7ML5517) Siemens FI 01 · 2016 4/367 4 © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 ■ Dimensional drawings Cable version, non-insulated welded flange (7ML5513) Cable version, insulated welded flange (7ML5513) Transmitter/ electronics Option for mounting eye only available for PFA insulated cable Stainless steel weight Ø12 (0.47) Ø25 (0.98) Ø12 (0.47) Ø25 (0.98) SITRANS LC500 cable versions, dimensions in mm (inch) Ø24 (0.94) Ø35 (1.37) 15 (0.60) Note: 1) Applicable for non-conductive media only. Cable can be shortened on site. Weight is included in measuring length. 2) Applicable for both liquids and solids. Cable cannot be shortened. Weight is not part of measuring length. 3) For Y02 lengths greater than 5 000 (197), cable is inactive and is not actively shielded. 4) Minimum length = 200 (7.87), maximum length = 5 500 (216.54) 5) Insertion length Y01 = Y02 + measuring length + 92 (3.62) 6) Insertion length Y01 = Y02 + measuring length + 15 (0.59) Mounting eye option Inactive tip 100 (3.9) Mounting eye Ø48 (1.88) Siemens FI 01 · 2016 Ø40 (1.57) Measuring Y02 Inactive length length Y01 (insertion length) min. = 5 000 (197) / max. = 35 000 (1 378) Mounting eye option 54 (2.12) Stainless steel flexible tube 20 (0.79) Y02 Inactive length Y01 (insertion length) min. = 5 000 (197) / max. = 35 000 (1 378) Measuring length 63 92 (3.62) (2.48) 20 (0.79) 4/368 Mounting eye Extended cable version with rod sensor welded flange (7ML5523) Extended cable version with rod sensor welded flange (7ML5523) Ø16 (0.63) Ø34.5 (1.36) Ø34.5 (1.36) Ø32 (1.26) Stainless steel flexible tube 350 (13.78) Ø9 (0.35) Ø9 (0.35) 20 (0.79) Measuring length Y01 (insertion length) min. = 1 000 (39.40) / max. = 35 000 (1 378) Stainless steel weight PFA insulated probe 350 (13.78) Measuring length 250 (9.84) Ø6 (0.24) 92 (3.62) 4 Stainless steel cable Y01 (insertion length) min. = 1 000 (39.40) / max. = 35 000 (1 378) 20 (0.79) © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 Cable version, non-insulated 1) Welded flange (7ML5513) Cable version, insulated 2) Welded flange (7ML5513) Transmitter/ electronics Option for mounting eye only available for PFA insulated cable 350 (13.78) Ø12 (0.47) Ø25 (0.98) 20 (0.79) Mounting eye option Ø40 (1.57) Mounting eye Ø12 (0.47) Ø25 (0.98) Ø48 (1.88) Ø24 (0.94) Ø35 (1.37) Note: 1) Applicable for non-conductive media only. Cable can be shortened on site. Weight is included in measuring length. 2) Applicable for both liquids and solids. Cable cannot be shortened. Weight is not part of measuring length. 3) For Y02 lengths greater than 5 000 (197), cable is inactive and is not actively shielded. 4) Minimum length = 200 (7.87), maximum length = 5 500 (216.54) 5) Insertion length Y01 = Y02 + measuring length + 92 (3.62) 6) Insertion length Y01 = Y02 + measuring length + 15 (0.59) Mounting eye option Inactive tip 100 (3.9) Stainless steel flexible tube Measuring Y02 Inactive length length 4) 6) Y01 (insertion length) min. = 5 000 (197) / max. = 35 000 (1 378) Y01 (insertion length) min. = 5 000 (197) / max. = 35 000 (1 378) Mounting eye Extended cable version with rod sensor 3) Welded flange (7ML5523) 5) Y02 Inactive length 63 92 (3.62) (2.48) Measuring length 4) 92 (3.62) 4 Ø34.5 (1.36) Extended cable version with rod sensor 3) Welded flange (7ML5523) Ø16 (0.63) Ø34.5 (1.36) 20 (0.79) Stainless steel weight, actual weight = (2.15 kg [4.75 lb]) Ø32 (1.26) Stainless steel flexible tube Y01 (insertion length) max. = 35 000 (1 378) Measuring length 350 (13.78) Stainless steel weight, actual weight = (1.27 kg [2.80 lb]) Ø9 (0.35) 54 (2.12) 250 (9.84) Ø6 (0.24) PFA insulated probe Y01 (insertion length) max. = 35 000 (1 378) Measuring length Stainless steel cable Ø9 (0.35) 15 (0.60) SITRANS LC500 cable versions, dimensions in mm (inch) Siemens FI 01 · 2016 4/369 © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 Rod version with stilling well threaded (7ML5515) Stainless steel stilling well Measuring length1) Vent holes or optional slots PFA insulated probe * Ø16 (0.63) or Ø24 (0.94) 150 (6) 205 (8.1) Y01 (insertion length) min. = 200 (7.87) / max. = 3 500 (138), Ø16 (0.63) min. = 200 (7.87) / max. = 5 500 (216), Ø24 (0.94) Ø16 (0.63) or Ø24 (0.94) Y02 1) 205 (8.1) Y01 (insertion length) min. = 200 (7.87) / max. = 3 500 (138), Ø16 (0.63) min. = 200 (7.87) / max. = 5 500 (216), Ø24 (0.94) Measuring length PFA insulated probe * Stainless steel flexible tube General purpose approval only. Standard configuration (all versions) M20: 160 (6.3) 1/2" NPT: 230 (9.1) With thermal isolator option (all versions) Ø35 (1.38) or Ø48 (1.89) * = 30 (1.18) inactive tip Note: 1) Minimum Y02 (active shield length) = 50 (1.96), minimum measuring length = 200 (7.87) 430 (16.9) With explosion-proof seal option (all versions) 270 (10.6) 4 1) 20 (0.79) Y02 1) Transmitter/ electronics Remote electronics with mounting bracket option threaded (7ML5515) 205 (8.1) Rod version threaded (7ML5515) Thermal isolator SITRANS LC500 rod versions, dimensions in mm (inch) 4/370 Siemens FI 01 · 2016 © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 Rod version Welded flange (7ML5515) Single piece flange (7ML5517) Rod version with stilling well Welded flange (7ML5515) Single piece flange (7ML5517) 150 (6) Y02 1) Measuring length1) Vent holes or optional slots PFA insulated probe Ø16 (0.63) or Ø24 (0.94) Ø35 (1.38) or Ø48 (1.89) Ø16 (0.63) or Ø24 (0.94) General purpose approval only. 2) Stainless steel stilling well Y01 (insertion length) min. = 200 (7.87) / max. = 3 500 (138), Ø16 (0.63) min. = 200 (7.87) / max. = 5 500 (216), Ø24 (0.94) * PFA insulated probe Stainless steel flexible tube * Y02 1) Measuring length1) 2) Y01 (insertion length) min. = 200 (7.87) / max. = 3 500 (138), Ø16 (0.63) min. = 200 (7.87) / max. = 5 500 (216), Ø24 (0.94) 205 (8.1) (Typical) Transmitter/ electronics Remote electronics with mounting bracket option Welded flange (7ML5515) Single piece flange (7ML5517) PTFE flange facing option single piece flange only (7ML5517) Raised face flange 4 PTFE flange facing No stilling well or enamel probe available with this option. * = 30 (1.18) inactive tip Flange facing (raised face) 205 (8.1) Standard configuration (all versions) Flange class M20: 160 (6.3) 1/2" NPT: 230 (9.1) Facing thickness ASME 150/300 2 (0.08) ASME 600/900 7 (0.28) PN16/25/40/64 2 (0.08) PTFE facing (additional) 2 (0.08) With thermal isolator option (all versions) Notes: 1) Minimum Y02 (active shield length) = 50 (1.96), minimum measuring length = 200 (7.87) 2) Insertion length does not include any raised face/gasket face dimension (see Flange Facing table above). 270 (10.6) 430 (16.9) With explosion-proof seal option (all versions) Thermal isolator SITRANS LC500 rod versions, dimensions in mm (inch) Siemens FI 01 · 2016 4/371 © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC500 ■ Schematics Ground lug Protective label Solid state switch relay (any polarity) Instrument system ground Measuring signal (minicoaxial cable) 4 Ground connection point for instrument system SITRANS LC500 connections 4/372 Siemens FI 01 · 2016 Type: Ser.: Date: Rev.: Tampering voids warranty 4 ... 20 mA current loop connection (any polarity) © Siemens AG 2016 Level Measurement Continuous level measurement - Capacitance transmitters SITRANS LC300 and LC500 Specials ■ Selection and ordering data LC300 and LC500 Specials1) LC300 and LC500 Specials1) Article No. Article No. LC300 Mounting Eye LC300 Cable Extensions, 316L stainless steel Spare mounting eye (LC300 PFA versions only) A5E01163717 LC300 Weight Kit, 316L stainless steel Kit, stainless steel cable extension, 1 m, adjustable by customer A5E01163688 Kit, stainless steel cable extension, 3 m, adjustable by customer A5E01163689 Kit, stainless steel cable extension, 5 m, adjustable by customer A5E01163690 Kit, stainless steel cable extension, 10 m, adjustable by customer A5E01163691 Kit, Spare stainless steel weight. To be used in any cable version of CLS300, or stainless steel cable version of LC300 Kit, stainless steel cable extension, 15 m, adjustable by customer A5E01163693 LC500 Gasket (IP65), Silicone Kit, stainless steel cable extension, 20 m, adjustable by customer A5E01163695 A5E01163727 LC300 Cable Extensions, 316 stainless steel with PFA coating Spare gasket, LC500 enclosure version, IP65 A5E01163728 LC500 Blind Lid Kit, PFA cable extension, 1 m A5E01163709 Spare LC500 aluminum blind lid A5E01163729 LC500 Mounting Eye Kit, PFA cable extension, 3 m A5E01163710 Kit, PFA cable extension, 5 m A5E01163711 Kit, PFA cable extension, 10 m A5E01163712 Kit, PFA cable extension, 15 m A5E01163713 Spare mounting eye (PFA cable version only) Kit, PFA cable extension, 20 m A5E01163714 LC500 Mounting Bracket Spare mounting bracket A5E01163717 A5E01163730 LC500 Sanitary Versions2) 1) Special flange sizes and facings are available. Please contact a local sales person for details. 2) Please contact a local sales person for part number and pricing. Customers interested in a custom designed device should consult a local sales person. For more information, please visit http://www.automation.siemens.com/aspa_app. Siemens FI 01 · 2016 4/373 4