© Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 - Standard ■ Overview ■ Configuration Installation 4 Pointek CLS300 (standard version) is an inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out buildup on the probe. Keep unit out of path of falling material, or protect probe from falling material. ■ Benefits • Active-Shield technology so measurement is unaffected by material buildup or nozzle interference in active shield section • Performs in extremely abrasive conditions because of solid rod construction • Three LED indicators for adjustment control, output status, and power • High-temperature version up to 400 °C (752 °F) Build up of material in active shield area does not affect switch operation. ■ Application Pointek CLS300 standard version has three LED indicators with basic relay and solid-state switch alarms. M The robust design of CLS300 makes it specifically applicable for heavy solids applications where abrasive materials occur as in the mining industry. in .5 0 Wetted parts are made of stainless steel with a PFA shield for high chemical resistance, and of ceramic and stainless steel for high temperature version. Materials with low or high dielectric constants can be accurately detected. The unique Active Shield suppresses interference from material buildup or long installation nozzles. The unique modular design of the Pointek CLS300 provides a wide range of configurations, process connections, extensions and approvals to meet the temperature and pressure requirements of specific applications. The modular design makes ordering easier and reduces stocking requirements. A wide range of probe configurations are available, including rod and cable versions. • Key Applications: liquids, slurries, bulk solids, relatively high pressure and temperature, hazardous areas, milling and mining applications ) (2 The fully potted electronics are unaffected by condensation, dust or vibration. Min. 50 (2) Install probe at least 50 (2) from tank wall. Note angle of repose and adjust accordingly. Pointek CLS300 installation, dimensions in mm (inch) Siemens FI 01 · 2016 4/43 © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 - Standard ■ Technical specifications Design Mode of operation Measuring principle Inverse frequency shift capacitive level detection Material (enclosure) Powder-coated aluminum with gasket Degree of Protection Standard: Type 4/NEMA 4/IP65 Optional: Type 4/NEMA 4/IP68 Change in picoFarad (pF) Cable inlet 2 x M20 x 1.5 thread (option: 2 x ½" NPT conduit entry including 1 plugged entry) Input Measured variable Output Output signal • Relay output - Max. contact voltage - Max. contact current - Max. switching capacity 4 - Time delay (ON and/or OFF) • Solid-state output - Output - Protection - Max. switching voltage Controls and displays 1 SPDT Form C relay • 30 V DC • 250 V AC • 5 A (DC) • 8 A (AC) • 150 W (DC) • 2 000 VA (AC) 1 ... 60 s 3 LEDs, for probe status, output status and power supply Potentiometers 2 potentiometers for time delay and sensitivity Switches 5 DIP switches for delay on/off, failsafe high/low, time delay test/adjust, high/low sensitivity, test delay settings Power supply Galvanically isolated Against reversed polarity (bipolar) • 30 V (DC) • 30 V peak (AC) 82 mA - Max. load current - Voltage drop < 1 V, typical at 50 mA - Time delay (pre or post switching) 1 ... 60 s Accuracy Resolution • Min. sensitivity (pF) • Max. temperature error Displays Supply Certificates and approvals General Purpose CSA, FM, CE, RCM Flameproof Enclosure with IS Probe ATEX II 1/2 G EEx d[ia] IIC T6 ... T1 ATEX II 1/2 D T100 °C Dust Ignition Proof with IS Probe ATEX II 1/2 D T100 °C CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T4 Explosion Proof Enclosure with IS Probe CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T4 1 % change in actual capacitance 0.2 % of actual capacitance value Rated operating conditions1) 12 ... 250 V AC/DC, 0 ... 60 Hz, galvanically isolated, 2 W Installation conditions • Location Indoor/outdoor Ambient conditions • Ambient temperature -40 ... +85 °C (-40 ... +185 °F)2) Marine Lloyds Register of Shipping, Categories ENV1, ENV2, and ENV5 Liquids, bulk solids, slurries and interfaces, and applications with viscous materials Min. 1.5 Overfill Protection WHG (Germany) VLAREM II (Belgium) Others Pattern Approval (China) Medium conditions • Relative dielectric constant r • Process temperature - Rod/Cable version - High-temperature version • Process pressure3) 1) -40 ... +200 °C (-40 ... +392 °F)2) -40 ... +400 °C (-40 ... +752 °F) -1 ... +35 bar g (-14.6 ... +511 psi g) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves starting on page 4/57. 2) Thermal isolator is used if process connection temperature exceeds 85 °C (185 °F). 3) Pressure rating of process seal is temperature dependent. See Pressure/ Temperature curves starting on page 4/57. Design: Probe Rod version High Temperature version Cable version Length Min. 250 mm (9.8 inch), max. 1 000 mm (40 inch) Min. 250 mm (9.8 inch), max. 1 000 mm (40 inch) Min. 1 000 mm (40 inch), max. 25 000 mm (984 inch) Sensor wetted parts PFA (no insulation on active probe), 316L stainless steel, PEEK isolators Ceramic (ZrO21)) isolators (no insulation on active probe), 316L stainless steel 316 stainless steel, optional PFA, PEEK isolators O-ring seal material FKM (optional FFKM)2) Graphite2) FKM (optional FFKM)2) Thermal isolator Optional Standard Optional Extension User selectable length User selectable length User selectable cable length 1) Zirconium Oxide 2) For caustic materials, consult a local sales person for alternative O-rings. For more information, please visit http://www.automation.siemens.com/aspa_app. 4/44 Siemens FI 01 · 2016 © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 - Standard Selection and Ordering data Article No. Selection and Ordering data Article No. Pointek CLS300 - Standard - Rod Version with Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present, and has the ability to tune out buildup on the probe. 7ML5650- Pointek CLS300 - Standard - Rod Version with Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present, and has the ability to tune out buildup on the probe. 7ML5650- 77777 - 7777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Add Order code Y01 and plain text: "Insertion length ... mm" Extended rod, factory adjusted length 250 ... 499 mm (9.8 ... 19.65 inch) Extended rod, factory adjusted length 500 ... 749 mm (19.69 ... 29.49 inch) Extended rod, factory adjusted length 750 ... 999 mm (29.53 ... 39.3 inch) Process connection Threaded, 316L stainless steel ¾" NPT [(Taper), ANSI/ASME B1.20.1] 1" NPT [(Taper), ANSI/ASME B1.20.1] 1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0A 0B 0C 1½" NPT [(Taper), ANSI/ASME B1.20.1] R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 0D 1A 1B R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 1D G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3A 3B 3D Welded flange, 316L stainless steel, raised face E F G Thermal isolator Without thermal isolator With thermal isolator [for process connection temperatures over 85 °C (185 °F)] Wetted seals FKM FFKM [for process temperatures above -20 °C (-4 °F)] Probe material 316L stainless steel with PFA lining and PEEK isolators 4 0 1 0 1 0 Approvals 1" ASME, 150 lb 1" ASME, 300 lb 1" ASME, 600 lb 5A 5B 5C 1½" ASME, 150 lb 1½" ASME, 300 lb 1½" ASME, 600 lb 5D 5E 5F 2" ASME, 150 lb 2" ASME, 300 lb 2" ASME, 600 lb 5G 5H 5J 3" ASME, 150 lb 3" ASME, 300 lb 3" ASME, 600 lb 5K 5L 5M 4" ASME, 150 lb 4" ASME, 300 lb 4" ASME, 600 lb 5N 5P 5Q Welded flange, 316L stainless steel, Type A flat faced DN 25, PN 16 DN 25, PN 40 DN 40, PN 16 6A 6B 6C DN 40, PN 40 DN 50, PN 16 DN 50, PN 40 6D 6E 6F DN 80, PN 16 DN 80, PN 40 DN 100, PN 16 6G 6H 6J Dust Ignition Proof with IS Probe: CE, RCM, ATEX II 1/2 D T100 °C C Flameproof Enclosure with IS Probe: CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6 ... T1, ATEX II 1/2 D T100 °C Flameproof Enclosure with IS Probe, with WHG approval: CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6 ... T1, ATEX II 1/2 D T100 °C D E Dust Ignition Proof with IS Probe: CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T4 F Explosion Proof Enclosure with IS Probe: CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T4 G General Purpose (CSA, FM) H General Purpose (CE, RCM) J General Purpose with WHG approval (CSA, FM, CE, RCM) K Enclosure and lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 2 x M20 x 1.5 cable inlet, IP65 2 x ½" NPT via adapter - cable inlet, IP68 2 x M20 x 1.5 cable inlet, IP68 Active shield length Standard length (125 mm threaded, 105 mm flanged) Extended shield (250 mm threaded, 230 mm flanged)1) Extended shield (400 mm threaded, 380 mm flanged)2) 6K DN 100, PN 40 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN 1092-1 standard.) Probe length (length from flange face) (threaded lengths include process thread) Note: No Y01 needed in Order code for standard lengths Standard version, rod 350 mm (13.78 inch) Extended rod, length 500 mm (19.69 inch) Extended rod, length 750 mm (29.53 inch) Extended rod, length 1 000 mm (39.37 inch) 77777 - 7777 1) A B C D 2) A B C D 0 1 2 Available with Probe version options B ... D, F, G only [ 500 mm (19.69 inch)] Available with Probe version options C, D, and G only [ 750 mm (29.53 inch)] We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Siemens FI 01 · 2016 4/45 © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 - Standard Selection and Ordering data Order code Further designs Please add "-Z" to Article No. and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, Part 18 and to ISO 9000 C11 Inspection Certificate Type 3.1 per EN 10204 C12 Operating Instructions 4 Note: The Operating Instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Level and Weighing manual DVD containing the ATEX Quick Start and manual library. See page 4/56 Accessories See page 4/56 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Selection and Ordering data Article No. Pointek CLS300 - Standard - Cable Version with Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present, and has the ability to tune out buildup on the probe. 7ML56517 7 7 77 - 77 7 7 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 316L stainless steel 1¼" NPT [(Taper), ANSI/ASME B1.20.1] 1½" NPT [(Taper), ANSI/ASME B1.20.1] R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 0C 0D 1D 3D Welded flange, 316L stainless steel, raised face 1½" ASME, 150 lb 1½" ASME, 300 lb 1½" ASME, 600 lb 5D 5E 5F 2" ASME, 150 lb 2" ASME, 300 lb 2" ASME, 600 lb 5G 5H 5J 3" ASME, 150 lb 3" ASME, 300 lb 3" ASME, 600 lb 5K 5L 5M 4" ASME, 150 lb 4" ASME, 300 lb 4" ASME, 600 lb 5N 5P 5Q Welded flange, 316L stainless steel, Type A flat faced DN 40, PN 16 DN 40, PN 40 DN 50, PN 16 6C 6D 6E DN 50, PN 40 DN 80, PN 16 DN 80, PN 40 6F 6G 6H DN 100, PN 16 DN 100, PN 40 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN 1092-1 standard.) 6J 6K Probe length (length from flange face) (threaded lengths include process thread) Note: No Y01 needed in Order code for standard lengths Extended cable, 3 000 mm (118.11 inch), length can be shortened by customer Extended cable, 6 000 mm (236.22 inch), length can be shortened by customer A B Extended cable, 500 ... 1 000 mm (19.69 ... 39.37 inch) E Extended cable, 1 001 ... 5 000 mm (39.41 ... 196.85 inch) F Extended cable, 5 001 ... 10 000 mm (196.89 ... 393.70 inch) G Extended cable, 10 001 ... 15 000 mm (393.74 ... 590.55 inch) Extended cable, 15 001 ... 20 000 mm (590.59 ... 787.40 inch) H J Extended cable, 20 001 ... 25 000 mm (787.44 ... 984.25 inch) K Add Order code Y01 and plain text: "Insertion length ... mm" 4/46 Siemens FI 01 · 2016 © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 - Standard Order code Selection and Ordering data Article No. Selection and Ordering data Pointek CLS300 - Standard - Cable Version with Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present, and has the ability to tune out buildup on the probe. 7ML5651- Further designs 77 7 77 - 77 77 Please add "-Z" to Article No. and specify Order code(s). Thermal isolator Without thermal isolator With thermal isolator [for process connection temperatures over 85 °C (185 °F)] Wetted seals FKM FFKM [for process temperatures above -20 °C (-4 °F)] Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text 0 1 Manufacturer's test certificate: M to DIN 55350, Part 18 and to ISO 9000 C11 Inspection Certificate Type 3.1 per EN 10204 C12 Operating Instructions Probe material Bare 316L stainless steel cable, PEEK isolators and 316L stainless steel cable weight PFA coated cable, PEEK isolators and 316L stainless steel cable weight 0 1 0 1 Note: The Operating Instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Level and Weighing manual DVD containing the ATEX Quick Start and manual library. See page 4/56 Accessories See page 4/56 4 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Approvals Dust Ignition Proof with IS Probe: CE, RCM, ATEX II 1/2 D T100 °C C Flameproof Enclosure with IS Probe: CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6 ... T1, ATEX II 1/2 D T100 °C Flameproof Enclosure with IS Probe, with WHG approval: CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6 ... T1, ATEX II 1/2 D T100 °C D E Dust Ignition Proof with IS Probe: CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T4 F Explosion Proof Enclosure with IS Probe: CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T4 G General Purpose (CSA, FM) H General Purpose (CE, RCM) J General Purpose with WHG approval (CSA, FM, CE, RCM) K Enclosure and lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 2 x M20 x 1.5 cable inlet, IP65 2 x ½" NPT via adapter - cable inlet, IP68 2 x M20 x 1.5 cable inlet, IP68 Active shield length Standard length (125 mm threaded, 105 mm flanged) Extended shield (250 mm threaded, 230 mm flanged)1) Extended shield (400 mm threaded, 380 mm flanged)1) 1) A B C D 0 1 2 Available with Probe version options A, B, F ... K, only [ 1 000 mm (39.7 inch)] We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Siemens FI 01 · 2016 4/47 © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 - Standard Selection and Ordering data Article No. Selection and Ordering data Article No. Pointek CLS300 - Standard - High Temperature Rod Version with Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present, and has the ability to tune out buildup on the probe. 7ML5652- Pointek CLS300 - Standard - High Temperature Rod Version with Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present, and has the ability to tune out buildup on the probe. 7ML5652- 7 7 7 00 7 - 7 7 7 7 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Add Order code Y01 and plain text: "Insertion length ... mm" Extended rod, factory adjusted length 250 ... 499 mm (9.8 ... 19.65 inch) Extended rod, factory adjusted length 500 ... 749 mm (19.69 ... 29.49 inch) Extended rod, factory adjusted length 750 ... 999 mm (29.53 ... 39.3 inch) Process connection Threaded, 316L stainless steel 4 ¾" NPT [(Taper), ANSI/ASME B1.20.1] 1" NPT [(Taper), ANSI/ASME B1.20.1] 1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0A 0B 0C 1½" NPT [(Taper), ANSI/ASME B1.20.1] R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 0D 1A 1B R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3D F G 1D 3A Approvals 3B Dust Ignition Proof with IS Probe: CE, RCM, ATEX II 1/2 D T100 °C C Flameproof Enclosure with IS Probe: CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6 ... T1, ATEXII 1/2 D T100 °C Flameproof Enclosure with IS Probe, with WHG approval: CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6 ... T1, ATEX II 1/2 D T100 °C D E Dust Ignition Proof with IS Probe: CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T4 F Explosion Proof Enclosure with IS Probe: CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T4 G General Purpose (CSA, FM) H General Purpose (CE, RCM) J General Purpose with WHG approval (CSA, FM, CE, RCM) K 5A 5B 5C 1½" ASME, 150 lb 1½" ASME, 300 lb 1½" ASME, 600 lb 5D 5E 5F 2" ASME, 150 lb 2" ASME, 300 lb 2" ASME, 600 lb 5G 5H 5J 3" ASME, 150 lb 3" ASME, 300 lb 3" ASME, 600 lb 5K 5L 5M 4" ASME, 150 lb 4" ASME, 300 lb 4" ASME, 600 lb 5N 5P 5Q Welded flange, 316L stainless steel, Type A flat faced DN 25, PN 16 DN 25, PN 40 DN 40, PN 16 6A 6B 6C DN 40, PN 40 DN 50, PN 16 DN 50, PN 40 6D 6E 6F DN 80, PN 16 DN 80, PN 40 DN 100, PN 16 6G 6H 6J 0 0 Enclosure and lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 2 x M20 x 1.5 cable inlet, IP65 A B 2 x ½" NPT via adapter - cable inlet, IP68 2 x M20 x 1.5 cable inlet, IP68 C D Active shield length Standard length (125 mm threaded, 105 mm flanged) Extended shield (250 mm threaded, 230 mm flanged)1) Extended shield (400 mm threaded, 380 mm flanged)2) 6K DN 100, PN 40 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN 1092-1 standard.) 0 1 2 1) Available with Probe version options B ... D, F, G only [ 500 mm (19.69 inch)] 2) Available with Probe version options C, D, and G only [ 750 mm (29.53 inch)] We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Probe length (length from flange face) (threaded lengths include process thread) Note: No Y01 needed in Order code for standard lengths Siemens FI 01 · 2016 E Probe material 316L stainless steel with ceramic (ZrO2) isolators 1" ASME, 150 lb 1" ASME, 300 lb 1" ASME, 600 lb 4/48 Wetted seals Graphite Welded flange, 316L stainless steel, raised face Standard version rod, 350 mm (13.78 inch) Extended rod, length 500 mm (19.69 inch) Extended rod, length 750 mm (29.53 inch) Extended rod, length 1 000 mm (39.37 inch) 7 7 7 00 7 - 7 7 7 7 A B C D © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 - Standard Selection and Ordering data Order code Further designs Please add "-Z" to Article No. and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, Part 18 and to ISO 9000 C11 Inspection Certificate Type 3.1 per EN 10204 C12 Operating Instructions Note: The Operating Instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Level and Weighing manual DVD containing the ATEX Quick Start and manual library. See page 4/56 Accessories See page 4/56 4 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Siemens FI 01 · 2016 4/49 © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 - Digital ■ Overview ■ Configuration Installation 4 Pointek CLS300 (digital version) is an inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out buildup on the probe. The digital version includes PROFIBUS PA, an LCD display, and advanced diagnostic features. Keep unit out of path of falling material, or protect probe from falling material. ■ Benefits • Active-Shield technology so measurement is unaffected by material buildup or nozzle interference in active shield section • Performs in extremely abrasive conditions because of solid rod construction • Push-button calibration, full-function diagnostics • High sensitivity allows installation in a wide range of liquids, solids or slurry applications • Integral LCD display allows for easy menu-driven setup • PROFIBUS PA communication (SIMATIC PDM compatible) Build up of material in active shield area does not affect switch operation. ■ Application M in .5 Pointek CLS300 digital version provides an integral LCD display for stand-alone use, with PROFIBUS PA communication (Profile version 3.0, Class B) when required. Solid-state switch alarm is standard. 0 ) (2 The robust design of CLS300 makes it specifically applicable for heavy solids applications where abrasive materials occur as in the mining industry. The fully potted electronics are unaffected by condensation, dust or vibration. Wetted parts are made of stainless steel with a PFA shield for high chemical resistance, and of ceramic and stainless steel for high temperature version. Materials with low or high dielectric constants can be accurately detected. The unique Active Shield suppresses interference from material buildup or long installation nozzles. The unique modular design of the Pointek CLS300 provides a wide range of configurations, process connections, extensions and approvals to meet the temperature and pressure requirements of specific applications. The modular design makes ordering easier and reduces stocking requirements. A wide range of probe configurations are available, including rod and cable versions. • Key Applications: liquids, slurries, bulk solids, relatively high pressure and temperature, hazardous areas, milling and mining applications 4/50 Siemens FI 01 · 2016 Min. 50 (2) Install probe at least 50 (2) from tank wall. Note angle of repose and adjust accordingly. Pointek CLS300 installation, dimensions in mm (inch) © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 - Digital ■ Technical specifications Mode of operation Measuring principle Inverse frequency shift capacitive level detection Input Measured variable • Max. load current • Voltage drop • Time delay (pre or post switching) Galvanically isolated Against reversed polarity (bipolar) • 30 V (DC) • 30 V peak (AC) 82 mA < 1 V, typical at 50 mA Programmable by user (0 ... 100 s) Fail-safe mode Min. or max. Connection Removable terminal block Dust Ignition Proof With IS Probe Intrinsically Safe4) Non-incendive Accuracy Resolution • Min. sensitivity (pF) • Max. temperature error Current consumption Certificates and approvals General Purpose Dust Ignition Proof Flameproof Enclosure With IS Probe Change in picoFarad (pF) Output Solid-state output • Output • Protection • Max. switching voltage Power supply Bus voltage (at process connection) 1 % change in actual capacitance 0.2 % of actual capacitance value Explosion Proof with IS Probe Rated operating conditions1) Installation conditions • Location Ambient conditions • Ambient temperature Medium conditions • Relative dielectric constant r • Process temperature - Rod/Cable version - High Temperature version • Process pressure3) Design Material (enclosure) Degree of protection Cable inlet Controls and displays Local display Configuration Indoor/outdoor -40 ... +85 °C (-40 ... +185 Marine °F)2) Liquids, bulk solids, slurries, and interfaces, and applications with viscous materials Min. 1.5 Others Communication • Standard: 12 ... 30 V DC • Intrinsically Safe: 12 ... 24 V DC 12.5 mA CSA, FM, CE, RCM ATEX II 1/2 D, 2 D IP6X T100 °C ATEX II 1/2 G EEx d[ia] IIC T6 ... T4 ATEX II 1/2 D T100 °C CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T4 ATEX II 1 G EEx ia IIC T6 ... T4 ATEX II 1/2 D, 2 D IP6X T100 °C CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T4 CSA/FM Class I, Div. 2, Groups A, B, C, D CSA/FM Class II, Div. 2, Groups F, G CSA/FM Class III T4 or T6 CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T4 Lloyds Register of Shipping, Categories ENV1, ENV2, and ENV5 Pattern Approval (China) PROFIBUS PA (IEC 61158 CPF3 CP3/2) Bus physical layer: IEC 61158-2 MBP-(IS) Device profile: PROFIBUS PA profile for Process Control Devices Version 3.0, Class B -40 ... +200 °C (-40 ... +392 °F)2) -40 ... +400 °C (-40 ... +752 °F) -1 ... +35 bar g (-14.6 ... +511 psi g) FISCO field device 1) Powder-coated aluminum with gasket Standard: Type 4/NEMA 4/IP65 Optional: Type 4/NEMA 4/IP68 2 x M20 x 1.5 thread (option: 2 x ½" NPT conduit entry including 1 plugged entry) LCD • Locally, using 3 button keypad (for standalone operation) • Remotely, using SIMATIC PDM (for installation on a network) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves starting on page 4/57. 2) Thermal isolator is used if process connection temperature exceeds 85 °C (185 °F) 3) Pressure rating of process seal is temperature dependent. See Pressure/ Temperature curves starting on page 4/57. 4) Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection Design: Probe Rod version High Temperature version Cable version Length Min. 250 mm (9.8 inch), max. 1 000 mm (40 inch) Min. 250 mm (9.8 inch), max. 1 000 mm (40 inch) Min. 1 000 mm (40 inch), max. 25 000 mm (984 inch) Sensor wetted parts PFA (no insulation on active probe), 316L stainless steel, PEEK isolators Ceramic (ZrO21)) isolators (no insulation on active probe), 316L stainless steel 316 stainless steel, optional PFA, PEEK isolators O-ring seal material FKM (optional FFKM)2) Graphite2) FKM (optional FFKM)2) Thermal isolator Optional Standard Optional Extension User selectable length User selectable length User selectable cable length 1) Zirconium Oxide 2) For caustic materials, consult a local sales person for alternative O-rings. For more information, please visit http://www.automation.siemens.com/aspa_app. Siemens FI 01 · 2016 4/51 4 © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 - Digital Selection and Ordering data Article No. Selection and Ordering data Article No. Pointek CLS300 - Digital - Rod with Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out buildup on the probe. 7ML5660- Pointek CLS300 - Digital - Rod with Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out buildup on the probe. 7ML5660- 77 7 77 - 77 77 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Add Order code Y01 and plain text: "Insertion length ... mm" Extended rod, factory adjusted length 250 ... 499 mm (9.8 ... 19.65 inch) Extended rod, factory adjusted length 500 ... 749 mm (19.69 ... 29.49 inch) Extended rod, factory adjusted length 750 ... 999 mm (29.53 ... 39.3 inch) Process connection Threaded, 316L stainless steel 4 ¾" NPT [(Taper), ANSI/ASME B1.20.1] 1" NPT [(Taper), ANSI/ASME B1.20.1] 1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0A 0B 0C 1½" NPT [(Taper), ANSI/ASME B1.20.1] R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 0D 1A 1B R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 1D G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 3D Thermal isolator Without thermal isolator With thermal isolator [for process connection temperatures over 85 °C (185 °F)] 3B 5A 5B 5C 1½" ASME, 150 lb 1½" ASME, 300 lb 1½" ASME, 600 lb 5D 5E 5F 2" ASME, 150 lb 2" ASME, 300 lb 5G 5H 2" ASME, 600 lb 5J 3" ASME, 150 lb 3" ASME, 300 lb 3" ASME, 600 lb 5K 5L 5M 4" ASME, 150 lb 4" ASME, 300 lb 4" ASME, 600 lb 5N 5P 5Q Welded flange, 316L stainless steel, Type A flat faced DN 25, PN 16 DN 25, PN 40 DN 40, PN 16 6A 6B 6C DN 40, PN 40 DN 50, PN 16 DN 50, PN 40 6D 6E 6F DN 80, PN 16 DN 80, PN 40 DN 100, PN 16 6G 6H 6J Probe material 316L stainless steel with PFA lining and PEEK isolators F G 0 1 0 1 0 Probe length (length from flange face) (threaded lengths include process thread) Note: No Y01 needed in Order code for standard lengths Dust Ignition Proof: CE, RCM, ATEX II 1/2 D, 2 D IP6X T100 °C B Intrinsically Safe1) CE, RCM, ATEX II 1 G EEx ia IIC T6 ... T4, ATEX II 1/2 D, 2 D IP6X T100 °C C Flameproof Enclosure with IS Probe: CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6 ... T4, ATEX II 1/2 D T100 °C D Dust Ignition Proof with IS Probe: CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T4 E Intrinsically Safe1) CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T4 F Explosion Proof Enclosure with IS Probe: CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T4 G General Purpose (CSA, FM) H General Purpose (CSA, FM, CE, RCM) J We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. 6K DN 100, PN 40 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN 1092-1 standard.) Siemens FI 01 · 2016 E Approvals 1" ASME, 150 lb 1" ASME, 300 lb 1" ASME, 600 lb 4/52 Wetted seals FKM FFKM [for process temperatures above -20 °C (-4 °F)] 3A Welded flange, 316L stainless steel, raised face Standard version, rod 350 mm (13.78 inch) Extended rod, length 500 mm (19.69 inch) Extended rod, length 750 mm (29.53 inch) Extended rod, length 1 000 mm (39.37 inch) 7 7 7 77 - 77 7 7 A B C D © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 - Digital Selection and Ordering data Article No. Selection and Ordering data Article No. Pointek CLS300 - Digital - Rod with Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out buildup on the probe. 7ML5660- Pointek CLS300 - Digital - Cable with Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out buildup on the probe. 7ML5661- 77 7 77 - 77 77 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Enclosure and Lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 2 x M20 x 1.5 cable inlet, IP65 2 x ½" NPT via adapter - cable inlet, IP68 2 x M20 x 1.5 cable inlet, IP68 Active shield length Standard length (125 mm threaded, 105 mm flanged) Extended shield (250 mm threaded, 230 mm flanged)2) Extended shield (400 mm threaded, 380 mm flanged)3) Process connection Threaded, 316L stainless steel A B C D 0 1 2 Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection 2) Available with Probe version options B ... D, F, G only [ 500 mm (19.69 inch)] Available with Probe version options C, D, and G only [ 750 mm (29.53 inch)] We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Selection and Ordering data 1¼" NPT [(Taper), ANSI/ASME B1.20.1] 1½" NPT [(Taper), ANSI/ASME B1.20.1] R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 0C 0D 1D 3D 4 Welded flange, 316L stainless steel, raised face 1) 3) 7 7 7 77 - 77 7 7 Order code Further designs Please add "-Z" to Article No. and specify Order code(s). Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, Part 18 and to ISO 9000 C11 Inspection Certificate Type 3.1 per EN 10204 C12 Operating Instructions Note: The Operating Instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Level and Weighing manual DVD containing the ATEX Quick Start and manual library. See page 4/56 Accessories See page 4/56 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. 1½" ASME, 150 lb 1½" ASME, 300 lb 1½" ASME, 600 lb 5D 5E 5F 2" ASME, 150 lb 2" ASME, 300 lb 2" ASME, 600 lb 5G 5H 5J 3" ASME, 150 lb 3" ASME, 300 lb 3" ASME, 600 lb 5K 5L 5M 4" ASME, 150 lb 4" ASME, 300 lb 4" ASME, 600 lb 5N 5P 5Q Welded flange, 316L stainless steel, Type A flat faced DN 40, PN 16 DN 40, PN 40 DN 50, PN 16 6C 6D 6E DN 50, PN 40 DN 80, PN 16 DN 80, PN 40 6F 6G 6H DN 100, PN 16 DN 100, PN 40 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN 1092-1 standard.) 6J 6K Probe length (length from flange face) (threaded lengths include process thread) Note: No Y01 needed in Order code for standard lengths Extended cable, 3 000 mm (118.11 inch), length can be shortened by customer Extended cable, 6 000 mm (236.22 inch), length can be shortened by customer Add Order code Y01 and plain text: "Insertion length ... mm" Extended cable, 500 ... 1 000 mm (19.69 ... 39.37 inch) Extended cable, 1 001 ... 5 000 mm (39.41 ... 196.85 inch) Extended cable, 5 001 ... 10 000 mm (196.89 ... 393.70 inch) Extended cable, 10 001 ... 15 000 mm (393.74 ... 590.55 inch) Extended cable, 15 001 ... 20 000 mm (590.59 ... 787.40 inch) Extended cable, 20 001 ... 25 000 mm (787.44 ... 984.25 inch) A B E F G H J K Siemens FI 01 · 2016 4/53 © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 - Digital Selection and Ordering data Article No. Selection and Ordering data Pointek CLS300 - Digital - Cable with Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out buildup on the probe. 7ML5661- Further designs 77 7 77 - 77 77 Please add "-Z" to Article No. and specify Order code(s). Thermal isolator Without thermal isolator With thermal isolator [for process connection temperatures over 85 °C (185 °F)] Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Wetted seals FKM FFKM [for process temperatures above -20 °C (-4 °F)] 4 Probe material Bare 316L stainless steel cable, PEEK isolators and 316L stainless steel cable weight PFA coated cable, PEEK isolators and 316L stainless steel cable weight 0 1 0 1 C12 0 1 Accessories See page 4/56 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. B Intrinsically Safe1) CE, RCM, ATEX II 1 G EEx ia IIC T6 ... T4, ATEX II 1/2 D, 2 D IP6X T100 °C C Flameproof Enclosure with IS Probe: CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6 ... T4, ATEX II 1/2 D T100 °C D Intrinsically Safe1) CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T4 F Explosion Proof Enclosure with IS Probe: CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T4 G General Purpose (CSA, FM) H General Purpose (CSA, FM, CE, RCM) J Enclosure and Lid Aluminum epoxy coated A B C D 0 1 2 1) Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection 2) Available with Probe version options A, B and, F ... K only [ 1 000 mm (39.7 inch)] We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Siemens FI 01 · 2016 Inspection Certificate Type 3.1 per EN 10204 See page 4/56 4/54 C11 Note: The Operating Instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Level and Weighing manual DVD containing the ATEX Quick Start and manual library. Dust Ignition Proof: CE, RCM, ATEX II 1/2 D, 2 D IP6X T100 °C Active shield length Standard length (125 mm threaded, 105 mm flanged) Extended shield (250 mm threaded, 230 mm flanged)2) Extended shield (400 mm threaded, 380 mm flanged)2) Manufacturer's test certificate: M to DIN 55350, Part 18 and to ISO 9000 Operating Instructions Approvals 2 x ½" NPT via adapter - cable inlet, IP65 2 x M20 x 1.5 cable inlet, IP65 2 x ½" NPT via adapter - cable inlet, IP68 2 x M20 x 1.5 cable inlet, IP68 Order code © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 - Digital Selection and Ordering data Article No. Selection and Ordering data Article No. Pointek CLS300 - Digital - High Temperature Rod version with Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out buildup on the probe. 7ML5662- Pointek CLS300 - Digital - High Temperature Rod version with Threaded or Flanged process connection Inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out buildup on the probe. 7ML5662- 77 7 0 7 - 77 77 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Add Order code Y01 and plain text: "Insertion length ... mm" Extended rod, factory adjusted length 250 ... 499 mm (9.8 ... 19.65 inch) Extended rod, factory adjusted length 500 ... 749 mm (19.69 ... 29.49 inch) Process connection Threaded, 316L stainless steel ¾" NPT [(Taper), ANSI/ASME B1.20.1] 1" NPT [(Taper), ANSI/ASME B1.20.1] 1¼" NPT [(Taper), ANSI/ASME B1.20.1] 0A 0B 0C 1½" NPT [(Taper), ANSI/ASME B1.20.1] R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] 0D 1A 1B R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 1D G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] Extended rod, factory adjusted length 750 ... 999 mm (29.53 ... 39.3 inch) 3A 3D Welded flange, 316L stainless steel, raised face 1" ASME, 150 lb 1" ASME, 300 lb 1" ASME, 600 lb 5A 5B 5C 1½" ASME, 150 lb 1½" ASME, 300 lb 1½" ASME, 600 lb 5D 5E 5F 2" ASME, 150 lb 2" ASME, 300 lb 2" ASME, 600 lb 5G 5H 5J 3" ASME, 150 lb 3" ASME, 300 lb 3" ASME, 600 lb 5K 5L 5M 4" ASME, 150 lb 4" ASME, 300 lb 4" ASME, 600 lb 5N 5P 5Q Welded flange, 316L stainless steel, Type A flat faced DN 25, PN 16 DN 25, PN 40 DN 40, PN 16 6A 6B 6C DN 40, PN 40 DN 50, PN 16 DN 50, PN 40 6D 6E 6F DN 80, PN 16 DN 80, PN 40 DN 100, PN 16 DN 100, PN 40 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN 1092-1 standard.) 6G 6H 6J 6K E F G Probe material 316L stainless steel with ceramic (ZrO2) isolators 4 0 0 B C D F G H J Enclosure and Lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 2 x M20 x 1.5 cable inlet, IP65 2 x ½" NPT via adapter - cable inlet, IP68 2 x M20 x 1.5 cable inlet, IP68 Active shield length Standard length (125 mm threaded, 105 mm flanged) Extended shield (250 mm threaded, 230 mm flanged)2) Extended shield (400 mm threaded, 380 mm flanged)3) A B C D 0 1 2 1) Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection 2) Available with Probe version options B ... D, F, G only [ 500 mm (19.69 inch)] 3) Available with Probe version options C, D, and G only [ 750 mm (29.53 inch)] We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Probe length (length from flange face) (threaded lengths include process thread) Note: No Y01 needed in Order code for standard lengths Standard version rod, 350 mm (13.78 inch) Extended rod, length 500 mm (19.69 inch) Extended rod, length 750 mm (29.53 inch) Extended rod, length 1 000 mm (39.37 inch) Wetted seals Graphite Approvals Dust Ignition Proof: CE, RCM, ATEX II 1/2 D, 2 D IP6X T100 °C Intrinsically Safe1) CE, RCM, ATEX II 1 G EEx ia IIC T6 ... T4, ATEX II 1/2 D, 2 D IP6X T100 °C Flameproof Enclosure with IS Probe: CE, RCM, ATEX II 1/2 G EEx d[ia] IIC T6 ... T4, ATEX II 1/2 D T100 °C Intrinsically Safe1) CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T4 Explosion Proof Enclosure with IS Probe: CSA/FM Class I, Div. 1, Groups A, B, C, D CSA/FM Class II, Div. 1, Groups E, F, G CSA/FM Class III T4 General Purpose (CSA, FM) General Purpose (CSA, FM, CE, RCM) 3B 7 7 7 0 7 - 77 7 7 A B C D Siemens FI 01 · 2016 4/55 © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 – Standard and Digital Selection and Ordering data Order code Article No. Operating Instructions - Standard Please add "-Z" to Article No. and specify Order code(s). English 7ML1998-5JH04 German Note: The Operating Instructions should be ordered as a separate line on the order. All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation 7ML1998-5JH34 Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, Part 18 and to ISO 9000 C11 Inspection Certificate Type 3.1 per EN 10204 C12 This device is shipped with the Siemens Level and Weighing manual DVD containing the ATEX Quick Start and Operating Instructions library. Operating Instructions - Digital Operating Instructions 4 Selection and Ordering data Further designs Note: The Operating Instructions should be ordered as a separate line on the order. This device is shipped with the Siemens Level and Weighing manual DVD containing the ATEX Quick Start and manual library. See page 4/56 Accessories See page 4/56 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. English 7ML1998-5JJ05 German Note: The Operating Instructions should be ordered as a separate line on the order. All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation 7ML1998-5JJ34 This device is shipped with the Siemens Level and Weighing manual DVD containing the ATEX Quick Start and Operating Instructions library. Accessories One metallic cable gland M20 x 1.5, -40 ... +80 °C (-40 ... +176 °F) with integrated shield connection (available for PROFIBUS PA) 7ML1930-1AQ General Purpose 1/2" NPT General Purpose Cable Entry IP68/IP69K NEMA6, -40 ... +100 °C (-40 ... +212 °F), cable size 6 ... 12 mm (0.236 ... 0.472 inch) 7ML1830-1JA M20 x 1.5 General Purpose Cable Entry IP68/IP69K NEMA6, -40 ... +100 °C (-40 ... +212 °F), cable size 7 ... 12 mm (0.275 ... 0.472 inch) 7ML1830-1JC Hazardous Locations 1/2" NPT EMC rated Cable Gland: Dust Ignition Proof, Flameproof Exd, and Increased Safety ATEX II 2 GD ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22, and in Gas Groups IIA,IIB and IIC) -60 ... +80 °C IP66, IP67, IP68, NEMA4X, cable sizes 5.5 ... 12 mm (0.216 ... 0.472 inch) 7ML1830-1JB M20 EMC rated Cable Gland: Dust Ignition Proof, Flameproof Exd, and Increased Safety ATEX II 2 GD ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22, and in Gas Groups IIA,IIB and IIC) -60 ... +80 °C IP66, IP67, IP68, NEMA4X, cable sizes 5.5 ... 12 mm (0.216 ... 0.472 inch) 7ML1830-1JD Blind threaded flanges are available. Customers interested in a custom designed device should consult a local sales person. For more information, please visit http://www.automation.siemens.com/aspa_app. Pointek Specials 4/56 Siemens FI 01 · 2016 See page 4/79 © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 – Standard and Digital ■ Characteristic curves Pressure/temperature curve CLS300 extended rod and cable probes Threaded process connections (7ML5650, 7ML5651, 7ML5660 and 7ML5661) Permitted operating pressures P 40 bar (580 psi) 30 bar (435 psi) 20 bar (290 psi) Atmospheric -40 ºF 14 ºF (-40 ºC) (-10 ºC) -1 bar (-14.5 psi) -150 ºC (-238 ºF) 4 10 bar (145 psi) -100 ºC -50 ºC (-148 ºF) (-58 ºF) 100 ºF (38 ºC) 0 ºC RT 50 ºC (32 ºF) (122 ºF) 200 ºF (93 ºC) 100 ºC (212 ºF) 300 ºF (149 ºC) 150 ºC (302 ºF) 400 ºF (204 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (482 ºF) -29 ºC (-20 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC 400 ºC (662 ºF) (752 ºF) Permitted operating temperature T Example: Permitted operating pressure = 30 bar (435 psi) at 75 °C Pointek CLS300 process pressure/temperature derating curves (7ML5650, 7ML5651, 7ML5660 and 7ML5661) Pressure/temperature curve CLS300 high temperature rod probes Threaded process connections (7ML5652 and 7ML5662) Permitted operating pressures P 40 bar (580 psi) 30 bar (435 psi) 20 bar (290 psi) Atmospheric 10 bar (145 psi) -40 ºF 14 ºF (-40 ºC) (-10 ºC) -1 bar (-14.5 psi) -150 ºC (-238 ºF) -100 ºC -50 ºC (-148 ºF) (-58 ºF) 100 ºF (38 ºC) 0 ºC RT 50 ºC (32 ºF) (122 ºF) 200 ºF (93 ºC) 100 ºC (212 ºF) 300 ºF (149 ºC) 150 ºC (302 ºF) -29 ºC (-20 ºF) 400 ºF (204 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (482 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC 400 ºC (662 ºF) (752 ºF) Permitted operating temperature T Pointek CLS300 process pressure/temperature derating curves (7ML5652 and 7ML5662) Siemens FI 01 · 2016 4/57 © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 – Standard and Digital Pressure/temperature curve CLS300 extended rod and cable probes ASME flanged process connections (7ML5650, 7ML5651, 7ML5660 and 7ML5661) Permitted operating pressures P 50 bar (725 psi) 40 bar (580 psi) 30 bar (435 psi) 4 ASME 300 lb1) 20 bar (290 psi) -40 ºF 14 ºF (-40 ºC) (-10 ºC) -1 bar (-14.5 psi) -150 ºC (-238 ºF) ASME 150 lb1) 10 bar (145 psi) Atmospheric -100 ºC -50 ºC (-148 ºF) (-58 ºF) 100 ºF (38 ºC) 0 ºC RT 50 ºC (32 ºF) (122 ºF) 200 ºF (93 ºC) 100 ºC (212 ºF) 300 ºF (149 ºC) 150 ºC (302 ºF) 400 ºF (204 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (482 ºF) -29 ºC (-20 ºF) 1) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC 400 ºC (662 ºF) (752 ºF) Permitted operating temperature T The curve denotes the minimum allowable flange class for the shaded area below. Pointek CLS300 process pressure/temperature derating curves (7ML5650, 7ML5651, 7ML5660, and 7ML5661) Permitted operating pressures P Pressure/temperature curve CLS300 high temperature rod probes ASME flanged process connections (7ML5652 and 7ML5662) 90 bar (1.305 psi) 80 bar (1.160 psi) 70 bar (1.015 psi) 60 bar (870 psi) ASME 600 lb1) 50 bar (725 psi) 40 bar (580 psi) 30 bar (435 psi) ASME 300 lb1) 20 bar (290 psi) ASME 150 lb1) 10 bar (145 psi) Atmospheric -40 ºF 14 ºF (-40 ºC) (-10 ºC) -1 bar (-14.5 psi) -150 ºC (-238 ºF) -100 ºC -50 ºC (-148 ºF) (-58 ºF) 100 ºF (38 ºC) 0 ºC RT 50 ºC (32 ºF) (122 ºF) 200 ºF (93 ºC) 100 ºC (212 ºF) 300 ºF (149 ºC) 150 ºC (302 ºF) -29 ºC (-20 ºF) 1) The curve denotes the minimum allowable flange class for the shaded area below. Pointek CLS300 process pressure/temperature derating curves (7ML5652 and 7ML5662) 4/58 Siemens FI 01 · 2016 400 ºF (204 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (482 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC 400 ºC (662 ºF) (752 ºF) Permitted operating temperature T © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 – Standard and Digital Pressure/temperature curve CLS300 extended rod and cable probes EN flanged process connections (7ML5650, 7ML5651, 7ML5660 and 7ML5661) Permitted operating pressures P 50 bar (725 psi) 40 bar (580 psi) 30 bar (435 psi) PN 401) 4 20 bar (290 psi) Atmospheric -40 ºF 14 ºF (-40 ºC) (-10 ºC) -1 bar (-14.5 psi) -150 ºC (-238 ºF) PN 161) 10 bar (145 psi) -100 ºC -50 ºC (-148 ºF) (-58 ºF) 100 ºF (38 ºC) 0 ºC RT 50 ºC (32 ºF) (122 ºF) 200 ºF (93 ºC) 100 ºC (212 ºF) 300 ºF (149 ºC) 150 ºC (302 ºF) 400 ºF (204 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (482 ºF) 300 ºC (572 ºF) -29 ºC (-20 ºF) 1) 600 ºF (315 ºC) 700 ºF (371 ºC) 350 ºC 400 ºC (662 ºF) (752 ºF) Permitted operating temperature T The curve denotes the minimum allowable flange class for the shaded area below. Pointek CLS300 process pressure/temperature derating curves (7ML5650, 7ML5651, 7ML5660 and 7ML5661) Pressure/Temperature Curve CLS300 High Temperature Rod Probes EN Flanged Process Connections (7ML5652 and 7ML5662) Permitted Operating Pressures P 50 bar (725 psi) 40 bar (580 psi) 30 bar (435 psi) PN 401) 20 bar (290 psi) Atmospheric -40 ºF 14 ºF (-40 ºC) (-10 ºC) -1 bar (-14.5 psi) -150 ºC (-238 ºF) PN 161) 10 bar (145 psi) -100 ºC -50 ºC (-148 ºF) (-58 ºF) 100 ºF (38 ºC) 0 ºC RT 50 ºC (32 ºF) (122 ºF) 200 ºF (93 ºC) 100 ºC (212 ºF) 300 ºF (149 ºC) 150 ºC (302 ºF) -29 ºC (-20 ºF) 1) 400 ºF (204 ºC) 200 ºC (392 ºF) 500 ºF (260 ºC) 250 ºC (482 ºF) 600 ºF (315 ºC) 300 ºC (572 ºF) 700 ºF (371 ºC) 350 ºC 400 ºC (662 ºF) (752 ºF) Permitted Operating Temperature T The curve denotes the minimum allowable flange class for the shaded area below. Pointek CLS300 process pressure/temperature derating curves (7ML5652 and 7ML5662) Siemens FI 01 · 2016 4/59 © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 – Standard and Digital ■ Dimensional drawings Rod version Threaded (7ML5650 and 7ML5660) Lid Thermal isolator Ø32 (1.26) Stainless steel weight Y01 (insertion length) min. = 500 (20)/max. = 25 000 (984) Y02 1) Ø10 (0.35) Ø32 (1.26) Note: 1) Extended Active Shield (Y02): standard length 125 (4.92). Optional active shield lengths: 250 (9.84) or 400 (15.75). Pointek CLS300 threaded process connections, dimensions in mm (inch) 4/60 Siemens FI 01 · 2016 Thermal isolator 247 (9.72) Y02 1) PFA insulated cable 250 (9.84) Y02 250 (9.84) Ø6 (0.24) Measuring length Stainless steel cable Y01 (insertion length) min. = 500 (20)/max. = 25 000 (984) 1) Cable version, insulated Threaded (7ML5651 and 7ML5661) 240 (9.45) XP, lid without window 146 (5.75) 234 (9.21) 159 (6.26) GP, DIP lid, without window Ø19 (0.75) Cable version, non-insulated Threaded (7ML5651 and 7ML5661) Stainless steel weight Y01 (insertion length) min. = 250 (9.8)/max. = 1 000 (39.37) Probe Lid with window Measuring length Ø19 (0.75) Ceramic isolator(s) M20: 135 (5.32) ½" NPT: 150 (5.91) Measuring length Y01 (insertion length) min. = 250 (9.8)/max. = 1 000 (39.37) Y02 1) Probe Measuring length 4 2 cable entries ½" NPT or M20 x 1.5 20 (0.79) 152 (5.98) Lid clip Electronics/ enclosure High temperature rod version Threaded (7ML5652 and 7ML5662) © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 – Standard and Digital Rod version Welded flange (7ML5650 and 7ML5660) High temperature rod version Welded flange (7ML5652 and 7ML5662) 2 cable entries ½" NPT or M20 x 1.5 Lid Lid clip M20: 135 (5.32) ½" NPT: 150 (5.91) Ø 19 (0.75) Cable version, insulated Welded flange (7ML5651 and 7ML5661) 270 (10.63) 263 (10.35) Flange Facing (raised face) Facing thickness ASME 150/300 2 (0.08) ASME 600/900 7 (0.28) PN16/40 2 (0.08) Y02 Stainless steel weight Measuring length Ø 10 (0.35) Y01 (insertion length) min. = 500 (20)/max. = 25 000 (984) 1) PFA insulated cable 250 (9.84) 250 (9.84) Ø 6 (0.24) Y01 (insertion length) min. = 500 (20)/max. = 25 000 (984) Stainless steel cable Measuring length Y02 1) Flange Class Ø 32 (1.26) Thermal isolator Ø 19 (0.75) Cable version, non-insulated Welded flange (7ML5651 and 7ML5661) Stainless steel weight 257 (10.12) XP, lid without window 168 (6.61) 181 (7.13) GP, DIP lid, without window 174 (6.85) Y01 (insertion length) min. = 250 (9.8)/max. = 1 000 (39.37) Probe Y02 1) Ceramic isolator(s) Measuring length Probe Lid with window Thermal isolator Y01 (insertion length) min. = 250 (9.8)/max. = 1 000 (39.37) Measuring length Y02 1) Electronics/ enclosure Ø 32 (1.26) Note: 1) Extended Active Shield (Y02): standard length 105 (4.13). Optional active shield lengths: 230 (9.06) or 380 (14.96). Insertion length does not include any raised face/gasket face dimension (see Flange Facing Table above) Pointek CLS300 flanged process connections, dimensions in mm (inch) Siemens FI 01 · 2016 4/61 4 © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 – Standard and Digital ■ Schematics Wiring: Pointek CLS300 standard White Black Red P2 (f ) (+) Switch bank Trip point S1 P1 K1 OFF GND 3 + Delay 2 1 Sensor L1 L3 Sensor status L2 Power on 1 2 3 Power supply 12 to 250 V AC/DC Output status 4 K4 NC NO NO K3 K2 Solid state switch: 30 V DC/30 V AC (peak), 82 mA max. Relay contact: 8 A at 250 V AC, 2 000 VA 5 A at 30 V DC, 150 W Notes: - Identification label is on underside of lid. Switch and potentiometer settings are for illustration purposes only (refer to operation/setup in manual). - All field wiring must have insulation suitable for at least 250 V. - Relay contact terminals are for use with equipment having no accessible live parts and wiring having insulation suitable for at least 250 V. - Maximum working voltage between adjacent relay contacts shall be 250 V. - Refer to the Instruction manual or contact Siemens representative for detailed wiring information. Wiring: Pointek CLS300 digital White Test input Reed contact* White Red (+) Black (-) Sensor Alarm output solid-state switch Orange (f) 24 V DC/PROFIBUS PA Power connection: 24 V DC or PROFIBUS PA bus (not polarity sensitive). Notes: Refer to the instruction manual or contact a Siemens representative for detailed wiring information. *Magnet activated sensor test A magnet can be used to test the sensor without opening the lid of the Pointek CLS300 digital version. Bring the magnet close to the test area indicated on the enclosure. The sensor test starts and finishes automatically after 10 seconds. Pointek CLS300 connections 4/62 Siemens FI 01 · 2016 © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS Specials ■ Selection and ordering data Pointek Specials1) Pointek Specials1) Article No. Article No. Kit, sensor for cable units, PPS, digital, FKM A5E01163678 Kit, sensor for cable units, PPS, standard, FFKM A5E01163679 Kit, sensor for cable units, PPS, digital, FFKM A5E01163680 Kit, sensor for cable units, PVDF, standard, FKM A5E01163681 Kit, sensor for cable units, PVDF, digital, FKM A5E01163682 CLS100 Miscellaneous Parts Custom length of cable is available only for 7ML5501-xxx1x and 7ML5501-xxx5x2) Kit, sensor for cable units, PVDF, standard, FFKM A5E01163683 CLS200 Gasket (IP65), Synprene Kit, sensor for cable units, PVDF, digital, FFKM A5E01163684 CLS100 Polycarbonate Lid and Gasket, FKM Kit, Lid and gasket, CLS100 enclosure version A5E01163671 CLS200 Mounting Bracket, 316L stainless steel Spare gasket, enclosure version (IP65 versions only) A5E01163672 CLS200 Gasket (IP68), Silicone Spare mounting bracket A5E01163685 CLS200 PROFIBUS Connector (IP65) Spare gasket, enclosure version (IP68 versions) A5E01163673 Spare, PROFIBUS connector (IP65 versions only) CLS200 Blind Lid A5E01163686 CLS200 Miscellaneous Parts CLS200 with FFKM O-rings (any version)2) CLS200 Electronics Spare aluminum blind lid (for standard versions only) A5E01163674 CLS200 Lid with window Test magnet, digital version 7ML1830-1JE Amplifier/power supply kit, standard version A5E03251681 Amplifier/power supply, digital version 7ML1830-1JF LCD display, digital version 7ML1830-1JK CLS300 Cable Extensions, 316L stainless steel Spare aluminum lid with window A5E01163676 CLS200 Sensor Kit for cable units Kit, sensor for cable units, PPS, Standard, FKM A5E01163677 Kit, stainless steel cable extension, 1 m, adjustable by customer A5E01163688 Kit, stainless steel cable extension, 3 m, adjustable by customer A5E01163689 Kit, stainless steel cable extension, 5 m, adjustable by customer A5E01163690 Kit, stainless steel cable extension, 10 m, adjustable by customer A5E01163691 Kit, stainless steel cable extension, 15 m, adjustable by customer A5E01163693 Kit, stainless steel cable extension, 20 m, adjustable by customer A5E01163695 Siemens FI 01 · 2016 4/79 4 © Siemens AG 2016 Level Measurement Point level measurement - RF Capacitance switches Pointek CLS Specials Pointek Specials1) Pointek Specials1) Article No. CLS300 Cable Extensions, 316 stainless steel with PFA coating 4 Article No. CLS300 Electronics Kits with drivers (for rod or cable versions) Kit, PFA cable extension, 1 m, adjustable by customer A5E01163697 Kit, PFA cable extension, 3 m, adjustable by customer A5E01163698 Kit, PFA cable extension, 5 m, adjustable by customer A5E01163699 Kit, PFA cable extension, 10 m, adjustable by customer A5E01163700 Kit, PFA cable extension, 15 m, adjustable by customer A5E01163701 Kit, PFA cable extension, 20 m, adjustable by customer A5E01163702 CLS300 Rod Kits, 316L stainless steel Kit, electronics with driver, standard CLS300. To be used in rod or cable versions with length less than 5 m.3)4) A5E01163723 Kit, electronics with driver, digital CLS300. To be used in rod or cable versions with length less than 5 m.3)4) A5E01163725 CLS300 Electronics Kits with drivers (for cable versions) Kit, electronics with driver, standard CLS300. To be used in cable versions with length greater than 5 m.3)4) A5E01163724 Kit, electronics with driver, digital CLS300. To be used in cable versions with length greater than 5 m.3)4) A5E01163726 CLS300 Electronics Kit, stainless steel rod 180 mm (7.09 inch) to be used with CLS300 units only (with standard active shield). Insertion length after installation is 350 mm (13.78 inch). A5E01163719 Kit, stainless steel rod 330 mm (12.99 inch) to be used with CLS300 units only (with standard active shield). Insertion length after installation is 500 mm (19.69 inch). A5E01163720 Kit, stainless steel rod 580 mm (22.83 inch) to be used with CLS300 units only (with standard active shield). Insertion length after installation is 750 mm (29.53 inch). A5E01163721 Kit, stainless steel rod 830 mm (32.68 inch) to be used with CLS300 units only (with standard active shield). Insertion length after installation is 1 000 mm (39.37 inch). A5E01163722 Kit, stainless steel rod 1 330 mm (52.36 inch) to be used with CLS300 units only (with standard active shield). Insertion length after installation is 1 500 mm (59.06 inch).2) Kit, stainless steel rod 1 830 mm (72.05 inch) to be used with CLS300 units only (with standard active shield). Insertion length after installation is 2 000 mm (78.74 inch).2) Test magnet, digital version 7ML1830-1JE Amplifier/power supply kit, standard version A5E03251683 Amplifier/power supply, digital version 7ML1830-1JF LCD display, digital version 7ML1830-1JK CLS300 Weight Kit, 316L stainless steel Kit, spare stainless steel weight. To be used in any cable version of CLS300 A5E01163727 CLS500 Gasket (IP65), Silicone Spare gasket, CLS500 enclosure version, IP65 A5E01163728 CLS500 Blind Lid Spare CLS500 aluminum blind lid A5E01163729 Kit, stainless steel rod customized length up to 1 m2) CLS500 Electronics Kit Kit, stainless steel rod customized length up to 2 m2) 1) Special flange sizes and facings are available. Please consult a local sales person for details. 2) Please consult a local sales person for part number and pricing 3) For General Purpose approvals only 4) To maintain approvals, qualified trained Siemens personnel required for part replacement Transmitter, MSP 2002-1, 330 PF 7ML1830-1JP Customers interested in a custom designed device should consult a local sales person. For more information, please visit http://www.automation.siemens.com/aspa_app. 4/80 Siemens FI 01 · 2016