View detail for ATF20V8C Reliability Qualification Report

PAGE 1 OF 7
ATMEL CORPORATION
Tel:(408)441-0311
Fax:(408)436-4200
ATF16V8C/16V8CZ/16LV8C EPLD RELIABILITY DATA *
- 125°C DYNAMIC OPERATING LIFE TEST (PLASTIC)
- 150°C RETENTION BAKE (PLASTIC)
- 15PSIG PRESSURE POT
- EXTENDED TEMPERATURE CYCLING
- 131C/85% RELATIVE HUMIDITY HAST TEST
- EXTENDED THERMAL SHOCK
*This report was generated from ATF16V8C reliability testing. This
data is applicable to the following device type due to same technology
grouping as defined in MIL-M-38535 Appendix A:
ATF20V8C
JULY 2007
2325 Orchard Parkway San Jose CA. 95131
PAGE 2 OF 7
ATF16V8C/16V8CZ/16LV8C
PLASTIC PACKAGE
125°C DYNAMIC OPERATING LIFE TEST
LOT
NUMBER
DATE
CODE
SAMPLE
SIZE
TOTAL
CKT-HRS(K)
NUMBER
OF FAILURES
5C2066-20
5C9613
114
114.0
0
6C2564-6
6C9646
115
115.0
0
6D1354-2
6D9702
120
120.0
0
6C0179B
6C9752
100
100.0
0
8D1152A
8D9904
120
120.0
0
9A0392A
9A9925
100
100.0
0
1A1895-1
1A0114
150
150.0
0
1A3940-1
1A0127
150
150.0
0
4G4082
4G0448
150
150.0
0
FAILURE RATE
TOTAL DEVICE HOURS
BEST ESTIMATE
1,119,000 DEVICE HOURS
λ
= 0.06% PER 1,000 HOURS
λ
EXTRAPOLATION TO 50°C VIA ARRHENNIUS
EQUATION AND ACTIVATION ENERGY OF 0.5eV
= 0.002% PER 1,000 HOURS (21 FITS)
50°C AMBIENT
CONFIDENCE ESTIMATE
λ
λ
60 = 0.003% PER 1,000 HOURS
60% CONFIDENCE (28 FITS)
90 = 0.007% PER 1,000 HOURS
90% CONFIDENCE (70 FITS)
PAGE 3 OF 7
ATF16V8C/16V8CZ/16LV8C
PLASTIC PACKAGE
150°C RETENTION BAKE
LOT
NUMBER
DATE
CODE
SAMPLE
SIZE
HOURS TO FAILURES
168
500
1000
5C2066-20
5C9613
50
0
0
0
6D1354-2
6D9818
100
0
0
0
6C0179B
6C9752
99
0
0
0
8C3242
8C9847
49
0
0
0
9A0392A
9A9925
50
0
0
0
1A1895-1
1A0114
150
0
0
0
1A3940-1
1A0127
150
0
0
0
4H5555-1
4H0501
50
0
0
0
6H4711-1
6H0718
100
0
0
0
FAILURE RATE
TOTAL DEVICE HOURS
798,000 DEVICE HOURS
BEST ESTIMATE
50°C AMBIENT
λ = 0.08% PER 1,000 HOURS
EXTRAPOLATION TO 50°C VIA ARRHENNIUS
EQUATION AND ACTIVATION ENERGY OF 0.5eV
λ = 0.001% PER 1,000 HOURS (13 FITS)
CONFIDENCE ESTIMATE
λ 60 = 0.002% PER 1,000 HOURS
60% CONFIDENCE (17 FITS)
λ 90 = 0.004% PER 1,000 HOURS
90% CONFIDENCE (41 FITS)
PAGE 4 OF 7
ATF16V8C/16V8CZ/16LV8C
PLASTIC PACKAGE
PRESSURE POT TEST
DATE
CODE
PACKAGE
TYPE
SAMPLE
SIZE
NUMBER OF FAILURES
AT INDICATED HOURS
(24)
(48)
(72) (96)
5C9535
20 PDIP
48
0
0
0
0
6C9752
20 PDIP
50
0
0
0
0
8C9847
20 PLCC
50
0
0
0
0
9A0109
20 TSSOP
300
0
0
0
0
1A0114
20 PDIP
50
0
0
0
0
4H0501
20 PDIP
50
0
0
0
0
PAGE 5 OF 7
ATF16V8C/16V8CZ/16LV8C
PLASTIC PACKAGE
EXTENDED TEMPERATURE CYCLING
-65°C to +150°C PLCC/TSOP/SOIC/PDIP
-55°C to +125°C CBGA
DATE
CODE
PACKAGE
TYPE
SAMPLE
SIZE
NUMBER
OF CYCLES
NUMBER
OF FAILURES
5C9535
20 PDIP
48
1000
0
6C9752
20 PDIP
50
1000
0
8C9847
20 PLCC
50
1000
0
9A9925
20 PDIP
50
1000
0
9A0109
20 TSSOP
300
1000
0
1A0114
20 PDIP
50
1000
0
5H0501
20 PDIP
50
1000
0
PAGE 6 OF 7
ATF16V8C/16V8CZ/16LV8C
PLASTIC PACKAGE
EXTENDED THERMAL SHOCK
-55°C TO +125°C
DATE
CODE
PACKAGE
TYPE
SAMPLE
SIZE
NUMBER
OF CYCLES
5C9535
20 PDIP
48
1000
NUMBER
OF FAILURES
0
PAGE 7 OF 7
ATF16V8C/16V8CZ/16LV8C
PLASTIC PACKAGE
131°C/85% RELATIVE HUMIDITY HAST TEST
LOT
NUMBER
DATE
CODE
PACKAGE
TYPE
SAMPLE
SIZE
NUMBER
OF HOURS
NUMBER
OF FAILIURES
6B2864B
6B9837
20 PLCC
50
100
0
6D1357
6D9834
20 PLCC
50
100
0
6C0179B
6C9752
20 PLCC
100
100
0
9A0392A
9A9925
20 PDIP
29
199
0
1A1895-1
1A0114
20 PDIP
40
50
0