Operating instructions I / 2010 Subject to change OSRAM GmbH Customer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg, Germany Tel. : (+49) 1803 / 677 - 200 (charges apply) Fax.: (+49) 1803 / 677 - 202 040808EN DMX controlled dimmer unit for RGB LED-modules OT DMX 3x1 RGB DIM Ver. 3.0 www.osram.com www.osram.de General Contents General Installation Operation Appendix Application and function ........................................................................2 Safety information .................................................................................2 Design and dimensions .........................................................................3 Wiring diagram ......................................................................................3 System extension ..................................................................................5 General functions ..................................................................................6 Operation modes...................................................................................6 Addressing ............................................................................................6 Troubleshooting ....................................................................................7 Technical data.......................................................................................8 Application and function The DMX protocol is established as one of the leading Lighting Management System protocol for dynamic RGB coloured lighting applications. The dimmer OT DMX 3x1 RGB DIM unit has been designed to be a suitable LED-module controller for a wide range of applications, when DMX protocol is adopted. The OT DMX 3x1 RGB DIM is a 3-channel PWM LED Dimmer unit for 10 V and 24 V LEDmodules providing a DMX control interface and PWM LEDdrivers as output. It is designed especially for RGB colormixing applications by controlling the brightness of individual LED modules. Main applications: • Large area effect lighting in architecture or cove lighting applications • Colour light effects and design-oriented lighting as creative element in discotheques, theatres, concerts etc. Main control unit advantages: • Full dimming range 0 −100% • Protection class II • Auto-reset in case of open-circuit, overload and over temperature • Short circuit protection in combination with OPTOTRONIC power supply • Compliance with all relevant lighting standards Safety information The following information is provided for your safety: • Please read these operating instructions carefully before installing and using the OT DMX 3x1 RGB DIM (referred as OT DMX 3x1 later on in the document). This is the only way to ensure that you use the equipment safely and correctly. Keep these operating instructions in a safe place for future reference. You should make sure that everyone who uses OT DMX 3x1 has read these operating instructions. • OT DMX 3x1 may only be installed by qualified personnel who have been appropriately trained and who have the relevant authority. The installation personnel must be familiar with the operating instructions. Mains power must be disconnected before performing any changes in the electrical installation. • The relevant safety and accident prevention regulations must be observed. • If the control cable or switch input is wired with external voltage, particularly with a mains voltage of 230 V, the unit may be destroyed. OSRAM operating instructions: OT DMX 3x1 RGB DIM Page2 Installation Design and dimensions Geometry (l x w x h): 80 mm x 40 mm x 22 mm Wiring diagram L N OT Converter constant voltage + - 10-24V DC in + - 10-24 V L N + R- OT DMX 3X1 RGB DIM Shield 1) DMX Controller 2) DMX in D+ D- + R G B RGB LED module GB- Note 1: Shield is common transmitter ground and must not be PE referenced in DMX controller Note 2: for instance OSRAM EASY DMX SO Fig. 1: DMX LED-System - OT Electronic Control Gear for LED Modules and OT DMX 3x1 RGB DIM. Wiring • Maximum output cable length is limited by EMI and depending on OPTOTRONIC power supply. The max. output cable length of the power supply has to be observed. • Control interface (DMX) is not isolated from the input and output terminal, so only the connection of an unearthed SELV DMX control signal is allowed. Connecting OT DMX 3x1 RGB DIM to constant voltage power supplies • The OT DMX 3x1 RGB DIM is placed between the OPTOTRONIC power supply and the LEDmodule. • Only 10V and 24V LED modules and power supplies are specified for the OT DMX 3x1 RGB DIM. • The faultless operation of OT DMX 3x1 RGB DIM is only warranted with the OPTOTRONIC power supplies for 10 V and 24 V. Operation with constant current power supplies or batteries is not allowed. • Operating voltage and power consumption of LED-Modules have to correspond with the OT’s rated values. Connecting OT DMX 3x1 RGB DIM to the LED-modules • Ensure that the LED modules rated value corresponds with the output voltage of the OPTOTRONIC power supply. • Do not exceed a LED power consumption of 10 W for 10 V supply or 24 W for 24 V supply per output channel. Page 3 OSRAM operating instructions: OT DMX 3x1 RGB DIM Installation Environment protection Maximum permissible ambient temperature (50°C) must not be exceeded. Ensure there is adequate space or ventilation to keep ambient temperature ≤ 50°C. In critical installations the temperature at tc has to be checked Wire stripping A = 12 mm, B = 7 mm General note: The luminaire manufacturer is responsible for providing the required clearances and creepage distances and also for the protection against electrical shock, especially for the line and load wires. OSRAM operating instructions: OT DMX 3x1 RGB DIM Page 4 Installation System extension 10-24 V 10-24 V 10-24 V Figure 2: DMX LED-System - System expansion An expansion of the system can be implemented by connecting the insulated DMX control line to the next OT DMX 3x1 RGB DIM device and so on. Page 5 OSRAM operating instructions: OT DMX 3x1 RGB DIM Operation General functions The OT DMX 3x1 RGB DIM unit is completely driven by means of DMX input signal. Therefore a DMX signal is control unit is required. By means of DMX signal, the unit performs the following: • Individual mixing of colours of the LED modules by means of pulse-width modulation • Fast colour changing sequences allowed by a very fast dimming characteristic • Full dimming range 0 −100% Operation modes Two different modes of operation are permitted. Modes are selected via DIP switch settings (see Addressing section for further details): • Normal operation: DIP switch 10 should always be Off (↓) for normal operation. • Test mode: DIP switch 10 shall be ON (↑). As consequence the OT DMX 3x1 RGB DIM runs in test mode. Addressing The DMX addresses can be set via DIP switches 1…9, located on the device bottom side. The set DMX address is for the RED-channel. The GREEN- and BLUE-channel will be addressed consecutively, e.g. set DMX address 001 RED-channel: address 001; GREEN-channel: address 002 and BLUE-channel: address 003. ON = ↑ Dip switch OFF = ↓ Dip switch pin setting DMX Addressing via DIP switches To use the DMX addressing table, first find the DMX address in the main block of the table. Then read the settings for pins 1 – 5 in the first column to the left and read the settings for pins 6 - 9 above the address. For example, to set the DMX address to 365, you need to set DIP switch pins 1, 3,4 and 6,7, 9 to ON, as highlighted in the table. OSRAM operating instructions: OT DMX 3x1 RGB DIM Page 6 Operation 6789 12345 ↓↓↓↓↓ ↑↓↓↓↓ ↓↑↓↓↓ ↑↑↓↓↓ ↓↓↑↓↓ ↑↓↑↓↓ ↓↑↑↓↓ ↑↑↑↓↓ ↓↓↓↑↓ ↑↓↓↑↓ ↓↑↓↑↓ ↑↑↓↑↓ ↓↓↑↑↓ ↑↓↑↑↓ ↓↑↑↑↓ ↑↑↑↑↓ ↓↓↓↓↑ ↑↓↓↓↑ ↓↑↓↓↑ ↑↑↓↓↑ ↓↓↑↓↑ ↑↓↑↓↑ ↓↑↑↓↑ ↑↑↑↓↑ ↓↓↓↑↑ ↑↓↓↑↑ ↓↑↓↑↑ ↑↑↓↑↑ ↓↓↑↑↑ ↑↓↑↑↑ ↓↑↑↑↑ ↑↑↑↑↑ ↓↓↓↓ ↑↓↓↓ ↓↑↓↓ ↑↑↓↓ ↓↓↑↓ ↑↓↑↓ ↓↑↑↓ ↑↑↑↓ ↓↓↓↑ ↑↓↓↑ ↓↑↓↑ ↑↑↓↑ ↓↓↑↑ ↑↓↑↑ ↓↑↑↑ ↑↑↑↑ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 Table 1. DMX address settings Note that: o Address 000: not used o Addresses 511 and 512 can’t be set, due to missing addresses for following GREEN and BLUE channel, e.g. 511 RED: 511; GREEN: 512; BLUE: no continuing address existing ! o DIP switch 10 should always be Off (↓) for normal operation. o Test mode: DIP switch 10: ON (↑) Troubleshooting The LED system is not working. Possible cause: • There is no power. • The LED module is faulty. Replace them. • The LED modules are off. Check the wiring connection correctness or run in test mode Page 7 OSRAM operating instructions: OT DMX 3x1 RGB DIM Appendix Technical data Designation: OT DMX 3x1 RGB DIM For LED modules: With respect to the output conditions: LINEARlight Colormix; LINEARlight Colormix Flex, COINlight Colormix, DRAGONchain Colormix, LINEARlight-DRAGON Colormix and other appropriate modules Supply input voltage range nom.: 10,5 - 24 V DC Supply input voltage range min - max: 8,5…25 V DC Power losses: 1,5 W Control signal: DMX (SELV equivalent) acc. USITT DMX-512A, DMX512 (DIN 56930-2) Electrical specification: ANSI/TIA/EIA-485-A-1998 Galvanic separation: No, SELV required (acc. to EIA-485) Control signal range: -7…+12VDC, (without damage to the device) Dimming modus: PWM Dimming range: 0…100% Dimming curve: approximate to EN 60929:2004 E.4.3.7 Output current max: 1 A for each channel Output load range: 0 - 10 W per channel @ 10,5 V DC / 0 - 24 W per channel @ 24 V DC Normative references: EN 55015, IEC 61347, EN 61547 Protection class: II Protection type: IP 20 Ambient temperature range: -20 °C to +50 °C No-load proof: Yes Short circuit protection: Yes, electrically reversible for each channel Overload protection: Yes, electrically reversible for each channel Over temperature protection: Yes, reversible Wire cross section for push in terminals: 0,5 mm² to 1.5 mm² massive leads 0,75 mm² to 1 mm² flexible leads Max. cable length: 10 m with 1.5 mm² massive leads Geometry (l x w x h): 80 mm x 40 mm x 22 mm Approvals: The CE symbol signifies compliance with the relevant EU Directives. OSRAM operating instructions: OT DMX 3x1 RGB DIM Page 8