pdf

OPTOTRONIC®
OT DALI 45/220-240/700 LTCS
700mA Constant Current LED Power Supply
with DALI and LEDset/DIPswitch
Technical
Information
Edition: Dec. 2012
subject to change
Technical data
Reference:
For LED modules:
Nominal Voltage:
OT DALI 45/220-240/700 LTCS
350 - 700 mA LED
220 – 240 VAC / DC
Line Current, nominal:
Mains Frequency:
Protection Class:
(Remark)
Output Current:
225 mA @ 230V
0/50/60 Hz
II
suitable for class I and class II luminaires
50 - 700 mADC
+/- 5% (Nominal 350-700mA), see load diagram
350/500/700mA selectable by DIPswitch
35 - 120 VDC
maximum 120VDC
45 W
Nominal minimum Load = 13W, see load diagram
> 0,95 (full load) @ 230V
> 0,90 (half load) @ 230V
7 W max.
87 %
full load at 230V
1,5 W
typical
195 – 264 VAC
Permitted voltage range
176 – 276 VDC
Permitted voltage range
DALI / Touch DIM / Touch DIM Sensor
DALI acc. to IEC 62386-101, IEC 62386-102, IEC
62386-207
7% - 100% / 14% -100%
for 700mA / 350mA
Amplitude modulation
LEDset
Yes
Yes
Automatic, reversible
Automatic, reversible
Automatic, reversible
-25 °C to +50 °C
85°C
(Remark)
Output voltage:
(Remark)
Output Power:
(Remark)
Rated Power factor:
Power Loss:
ECG efficiency:
(Remark)
Power Loss in standby mode
(Remark):
Input Voltage:
(Remark)
DC Voltage:
(Remark)
Dimmable:
(Remark)
Dimming Range:
(Remark)
Internal Control:
No-load proof:
Hot plug functionality:
Short circuit protection:
Overload protection:
Overtemperature protection:
Ambient temperature range, ta:
Max. case temperature at tc point:
Max. case temperature at tc point in
emergency mode
ECG Lifetime:
(Remark)
20121218
AA32184
98 °C
50.000 h
At tcase= 75 °C at tc point and 10% failure rate
Page 1 of 12
OPTOTRONIC®
OT DALI 45/220-240/700 LTCS
700mA Constant Current LED Power Supply
with DALI and LEDset/DIPswitch
Technical
Information
Edition: Dec. 2012
subject to change
Maximum casing temperature in
110 °C
case of fault:
Inrush current:
25 A
(Remark)
twidth = 260 µs (measured at 50% Ipeak)
Max. no. of ECG @ circuit breakers 10
18
A (B type):
Max. no. of ECG @ circuit breakers 16
47
A (B type):
Max. no. of ECG @ circuit breakers 16
A (B type):
64
in combination with EBN-OS
Mains (grey)
DALI (red)
Functional earth (grey)
Terminal:
LEDset (grey [GNDset], purple [Vset], orange
[NTCset]; blue [+12Vset])
LEDModule ( [+] red/ [-] black)
Cable cross section input side:
0,2 mm² – 1,5 mm²
(Remark)
Wire preparation length Input side:
Solid and flexible
8,5 – 9,5 mm
Cable cross section output side:
0,2 mm² – 1,5 mm²
(Remark)
Wire preparation length output side:
Max. cable length - system:
Geometry (l x b x h):
Weight:
IP Code:
Safety:
Performance:
Radio interference:
Harmonic content:
Immunity:
Emergency lighting
Solid and flexible
8,5 – 9,5 mm
2m
123 x 79 x 33 mm (K3)
240 g
IP20
EN 61347-1, EN 61347-2-13
EN 62384
EN 55015:2006+A1:2007+A2:2009
EN 61000-3-2
EN 61547
Suitable for Emergency Luminaires acc. to IEC 605982-22
≥ 0,98
Emergency Ballast Lumen Factor
(EBLF) at 25 °C
Surge capability:
Galvanic isolation
primary/secondary :
(Remark)
L-N: 1kV, L/N – Functional Earth: 2kV
3,75 kVrms
SELV equivalent
Approvals:
20121218
AA32184
Page 2 of 12
OPTOTRONIC®
OT DALI 45/220-240/700 LTCS
700mA Constant Current LED Power Supply
with DALI and LEDset/DIPswitch
Technical
Information
Edition: Dec. 2012
subject to change
Ordering/Version information
OT DALI 45/220-240/700 LTCS
Version
AA32184
EAN 10 (1 pc)
4008321819192
EAN 40 (20 pcs)
4008321819208
Remark:
An optional cable clamp is available. This cable clamp can be snapped onto the ECG and thus converts it
into an ECG suitable for independent installation. Suitable cables are listed in cable clamp datasheet.
QT Cable Clamp K3
OTp Cable Clamp
20121218
AA32184
EAN 10 (1 pc)
4008321190741
4008321966155
Page 3 of 12
EAN 40 (10 pcs)
4008321190758
4008321966162
OPTOTRONIC®
Technical
Information
OT DALI 45/220-240/700 LTCS
700mA Constant Current LED Power Supply
with DALI and LEDset/DIPswitch
Edition: Dec. 2012
subject to change
Geometry
PRI
Wiring diagram
~
~
DA
DA
OT DALI 45/220-240/700 LTCS
220-240 VAC/DC
DALI / Touch Dim
FE
DIP1
DIP2
GNDset
Vset
NTCset
+12Vset
R
NTC
+
LED Module
Connection example. LEDSet (Vset/NTCset) and DALI/TouchDIM connections are optional
20121218
AA32184
Page 4 of 12
OPTOTRONIC®
OT DALI 45/220-240/700 LTCS
700mA Constant Current LED Power Supply
with DALI and LEDset/DIPswitch
Technical
Information
Edition: Dec. 2012
subject to change
Output Characteristics
[B] Nominal Operating Range, [A] + [B] Absolute Output Power Range
NOTE (1): The forward voltage of LED modules may vary significantly with temperature and
current. Dimming down typically reduces the forward voltage. Ensure the forward voltage of
LED modules is always ≥ 35V, even when dimmed down, otherwise the reversible protection
is triggered resulting in no output
power.
20121218
AA32184
Page 5 of 12
OPTOTRONIC®
Technical
Information
OT DALI 45/220-240/700 LTCS
700mA Constant Current LED Power Supply
with DALI and LEDset/DIPswitch
Edition: Dec. 2012
subject to change
Efficiency [%]
Typical Efficiency and Power Factor versus Load
100
1.5
90
1.4
80
1.3
PF
70
1.2
350mA
700mA
60
1.1
50
1.0
40
0.9
30
0.8
20
0.7
10
0.6
0
0.5
15
20
25
30
Output Power [W]
20121218
AA32184
Page 6 of 12
35
40
45
Power Factor
500mA
OPTOTRONIC®
OT DALI 45/220-240/700 LTCS
700mA Constant Current LED Power Supply
with DALI and LEDset/DIPswitch
Technical
Information
Edition: Dec. 2012
subject to change
DIPswitch
The nominal output current of the constant current LED power supply is set either by the DIPswitch and the
LEDset interface:
Setting
DIP1
DIP2
Iout_nom
P max
D
C
B
A1)
Off
On
On
Off
Off
On
Off
On
700mA
350mA
500mA
700mA
45W
42W
45W
45W
Vset Open, NTCset open,
no digital dimming
Iout = 0mA 2)
Iout = 350mA
Iout = 500mA
Iout = 700mA
1) Factory setting
2) LEDset interface unplug protection is enabled
Settings A, B, C are intended to set the nominal output current to one of the standard values
(350,500,700) and optionally use Vset, NTCset and DALI/TouchDIM to dim down the current.
Setting D is intended to use the LEDset interface to define the nominal output current level in the range 50
– 700mA, see the OPTOTRONIC_LEDset_Application_Guide for further details.
Settings A and D differ from the protection against accidental LEDset interface disconnection (enabled in
D)
The maximum output current is controlled by the Vset input voltage as following:
Iout_max
Iout_nom  (Vset-1) / 9
0 mA
Iout_nom
Iout_nom
0 mA
Vset
1V .. 10V
0V .. 1V
10V .. 12V
10V .. 11V
11V .. 12V
DIP switches setting
A, B, C, D
A, B, C, D
A, B, C
D
D
LEDset interface
LEDset allows to control the output current of the control gear (ref. to LEDset application note).
The input voltage of the Vset pin defines the output current relative to the maximum nominal
current of the control gear.
LEDset interface is not isolated to the secondary side of the LED driver output.
+12Vset
Vset
NTCset
GNDset
Auxiliary supply 12V +15/-8%, 15mA max.
Signal input, included current source 274µA
0V < Vset < 12V +15%
NTC Input
Reference ground for +12Vset, NTCset and Vset
The relation between input voltage / Rset and output current is as following:
20121218
AA32184
Page 7 of 12
OPTOTRONIC®
OT DALI 45/220-240/700 LTCS
700mA Constant Current LED Power Supply
with DALI and LEDset/DIPswitch
Output current vs. Vset (setting A)
Iout = IOUT _NOM
Vset −1V
10V−1V
between Imin and Imax
Output current vs. Rset (setting A)
𝑅𝑠𝑒𝑡 =
1
𝐼𝑜𝑢𝑡
274𝑢𝐴 𝐼𝑂𝑈𝑇 _𝑁𝑂𝑀
20121218
AA32184
∗ 10𝑉 − 1𝑉 + 1𝑉
[Ω] between Imin and Imax
Page 8 of 12
Technical
Information
Edition: Dec. 2012
subject to change
OPTOTRONIC®
Technical
Information
OT DALI 45/220-240/700 LTCS
700mA Constant Current LED Power Supply
with DALI and LEDset/DIPswitch
Edition: Dec. 2012
subject to change
LEDset and DIPswitch
The output current could also be set in combination with the DIPswitch current pre-selection
(350,500 and 700mA) and the LEDset interface. In those three operation modes the ECG does
not switch off as soon as Vset exceeds 11V (no protection region).
A setting = 700mA
LEDset
700mA
600mA
B setting =
500mA
LEDset
Iout
500mA
400mA
C setting = 350mA
LEDset
300mA
200mA
100mA
50mA
OFF
1V
3V
5V
Vset
7V
9V
11V
Temperature sensor (NTCset)
The optional external temperature sensor (NTC) must be connected between GNDset and
NTCset. The Iout_nom is linearly reduced from 100% down to 50% depending on the NTC
resistor values respectively from 6.3kΩ down to 5.0kΩ, with lower values until 4.3kΩ the output
current remain at 50% and then it is switched OFF (it turns ON again automatically with values
greater than 5.0kΩ).
The following table reports some example of typical NTC values (Murata NCP18) and related
temperature thresholds (NTC resistor tolerance may affect the threshold).
NTC
Type
[kΩ]
Start Temperature
Derating
[6.3kΩ] °C
End Temperature
Derating
[5.0kΩ] °C
Shut down
Temperature
[4.3kΩ] °C
10
15
22
33
47
68
100
37.7
45.7
55.8
65.8
75.5
85.0
96.0
44.4
51.7
62.2
72.4
82.5
92.1
103.5
49.0
55.7
66.5
76.8
87.1
96.9
108.6
20121218
AA32184
Page 9 of 12
OPTOTRONIC®
Technical
Information
OT DALI 45/220-240/700 LTCS
700mA Constant Current LED Power Supply
with DALI and LEDset/DIPswitch
Edition: Dec. 2012
subject to change
Threshold would vary on the used NTC component and tolerance.
Thermal derating
percentage factor on
Output Current
100%
Final
level %
0%
Start
derating
End
derating
Shut
down
NTC
temperature (°C)
Internal Thermal protection
The LED power supply is equipped with an integrated temperature protection system, in addition
to the external temperature sensor (NTCset). If the product operates at too high temperature, the
output current Iout_nom is reduced by 50%; the protection is reversible.
DALI operation mode / TouchDIM
The Max DALI level and the Min DALI level parameters are automatically adapted to the
Minimum Physical Level each time the user modify the DIPswitch position, the LEDset setting or
the dimming curve type is changed from log. to lin. and vice versa.
DIP switch
700mA
700mA
500mA
500mA
350mA
350mA
20121218
AA32184
Ledset
100%
50%
100%
50%
100%
50%
DALI physical min Log Curve
157
182
170
196
182
208
Page 10 of 12
DALI physical min Lin Curve
18
37
26
51
37
73
OPTOTRONIC®
OT DALI 45/220-240/700 LTCS
700mA Constant Current LED Power Supply
with DALI and LEDset/DIPswitch
Technical
Information
Edition: Dec. 2012
subject to change
DC Operation
The power supply can operate also in DC voltage range from 176Vdc to 276Vdc at Tamb_MAX
50°C.
Earth connection
Earth connection is not required but may be used to improve EMI performance of the installation.
Wrong wiring
This control gear is inherently protected against wrong wiring. The wrong connections between
LED+ with Vset, NTCset and GNDset could damage irreversibly the ECG. All the other wrong
wirings on the secondary side, once removed, make the ECG work regularly. LED- and GNDset
terminals cannot be connected together. Vset should not be applied with a voltage in case the
power supply isn’t supplied.
General notes
Proper and safety usage and installation of the product shall comply to product
datasheet, OPTOTRONIC Technical guide, DALI Technical Guide and LEDset
application guides. Refer to the latest guides versions available at www.osram.com
20121218
AA32184
Page 11 of 12
OPTOTRONIC®
OT DALI 45/220-240/700 LTCS
700mA Constant Current LED Power Supply
with DALI and LEDset/DIPswitch
Technical
Information
Edition: Dec. 2012
subject to change
Installation notes
The luminaire manufacturer is responsible for providing the required clearances and creepage
distances and also for the protection against electrical shock, especially for the line and load
wires according EN 60598.
Instruction sheet
Please consult the instruction sheet for further important information on e.g. wire stripping and
wiring limitations in system installations. The instruction sheet is enclosed with the device or
available upon request.
20121218
AA32184
Page 12 of 12