ACT20P – Current measuring transducer
Simple and quick configuration
DIP switches and potentiometers are located
on the front, which means they’re quickly
accessible even when installed.
Precise measured values
The real-value effective procedure allows you
to record the connected load’s real power
consumption, so you can reliably identify when
levels exceed or fall below the nominal current.
,
W
D
Easy to install
The asymmetrical cable bushing makes it
easier to feed through the power cable and
permits precise measurement on an extremely
small space.
22.5 mm
High process reliability
Reliable function thanks to a galvanic four-way
isolation and an impulse withstand voltage of
6.4 kV according to IEC 61010-2-201
N9
D.32
2028820000
ACT20P – Current measuring transducer
ACT20P-CMT
• Measuring and monitoring of AC/DC current
• Input/output electrically isolated
• Input and output ranges are adjustable
• C ontact-free through-hole technology
• R elay output for limit value alarm with switching
threshold, delay, hysteresis
Output signals *
Input signal
Current
Current, voltage
*
44
Output
Output
43
Supply
+
I for AC
42
mA
+
Input
-
V
I for DC
-
41
Output signal
Signal converters
Current-measuring transducer
Power supply
Relay
24
+16.8...31.2 V DC
54
Output
Output
23
22
Ps
U/I
analog
output
Technical data
Input
Input measurement range
52
Input
CO
21
51
&XUUHQW
VLJQDO
configurable, 0…1/5/10 A AC (RMS) or DC
GND
53
Supply
+LJKDODUP
t
D
t
+LJKDODUPVHWSRLQW
+\VWHUHVLV
Input signal
Input frequency
Output (analogue)
Output voltage [output analogue]
Output current [output analogue]
Load resistance voltage [output analogue]
Load resistance current [output analogue]
Output (digital)
Type
Rated switching current
Max. switching voltage, AC
General data
Galvanic isolation
Accuracy
Configuration
Step response time
Temperature coefficient
Supply voltage
Insulation coordination
Rated voltage
Standards
Impulse withstand voltage
Test voltage
Pollution degree
Overvoltage category
Current-carrying cable in feed-through hole, Diameter 10.5 mm
AC: 15…700 Hz
adjustable, 0...10 V, 2…10 V, 0...5 V, 1...5 V, -5…+5 V, -10...+10 V
adjustable, 0...20 mA, 4...20 mA, -20…+20 mA
≥ 10 kΩ
≤ 600 Ω
W!WDG
2XWSXW
WDG$ODUPGHOD\
/RZDODUP
W!WDG
/RZDODUPVHWSRLQW
W
2XWSXW
W
WDG$ODUPGHOD\
7LPH
WDG$ODUPGHOD\
5HOD\GHHQHUJL]HG/('\HOORZ´2))µ 5HOD\HQHUJL]HG/('\HOORZ´21µ
',3VZLWFK6
&XUUHQWLQSXWUDQJH $
█
$
$
$
█
█
$
$
$
█
█
$
300 V ACrms
IEC 61010-1:2010, 3rd Edition, IEC 61010-2-201:2013, 1st Edition,
EN 61326-1
6.4 kV (1.2/50 µs)
4 kV
2
III
1,5 / 0,5 / 2,5
113,6 / 22,5 / 117,2
WWDG
+\VWHUHVLV
0HDVXULQJPHWKRG
7UXH506
$ULWKPHWLFDYHUDJH
$ODUPGHOD\WLPH
V
V
V
V
0HDVXULQJUDQJH
PRQLWRULQJ
<HV
1R
Dimensions
Clamping range (nominal / min. / max.)
Tiefe / Breite / Höhe
Note
7LPH
WDG$ODUPGHOD\
&XUUHQW
VLJQDO
Relay, 1 CO contact, Open or closed-circuit principle, with alarm delay
time (configurable) 0 s ⁄ 2 s ⁄ 5 s ⁄ 10 s
6A
250 V
4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
< 0.5 % of end value
DIP switch and potentiometer, for thresholds (overcurrent ⁄
undercurrent), delay and hysteresis
< 220 ms (10...90 %)
≤ 200 ppm/K
18...30 V DC
WWDG
█
█
█
█
█
2XWSXWUDQJH
9
9
9
9
9
9
P$
P$
P$
',3VZLWFK6
█
█
█
█
█
█
█
█
█
█
█
█
$ODUPUHOD\DFWLRQ
(QHUJL]HG
'HHQHUJL]HG
$ODUPK\VWHUHVLV
$ODUPW\SH
+LJKDODUP
/RZDODUP
█
█
█
█
2XWSXWHUURUDFWLRQ
8SVFDOH
'RZQVFDOH
7UDQVIHUIXQFWLRQ
1RUPDO
,QYHUVH
█
█
█
21
$&73&07$25&6
$&73&07$25&6
$&73&07$25&6$&73&075&6
Ordering data
Input measurement range 0...5/10 A
Input measurement range 0...20/25/30 A
Input measurement range 0...40/50/60 A
Input measurement range 0...40/50/60 A
Note
Type
ACT20P-CMT-10-AO-RC-S
ACT20P-CMT-30-AO-RC-S
ACT20P-CMT-60-AO-RC-S
ACT20P-CMT-60-RC-S
Qty.
1
1
1
1
Order No.
1510470000
1510540000
1510440000
1510390000
Accessories
Note
2028820000
D.33