Signal converters ACT20P – Current measuring transducer Simple and quick configuration DIP switches and potentiometers are located on the front, which means they’re quickly accessible even when installed. Precise measured values The real-value effective procedure allows you to record the connected load’s real power consumption, so you can reliably identify when levels exceed or fall below the nominal current. , W D Easy to install The asymmetrical cable bushing makes it easier to feed through the power cable and permits precise measurement on an extremely small space. 22.5 mm High process reliability Reliable function thanks to a galvanic four-way isolation and an impulse withstand voltage of 6.4 kV according to IEC 61010-2-201 N9 D.32 2028820000 ACT20P – Current measuring transducer ACT20P-CMT • Measuring and monitoring of AC/DC current • Input/output electrically isolated • Input and output ranges are adjustable • C ontact-free through-hole technology • R elay output for limit value alarm with switching threshold, delay, hysteresis Output signals * Input signal Current Current, voltage * 44 Output Output 43 Supply + I for AC 42 mA + Input - V I for DC - 41 Output signal Signal converters Current-measuring transducer Power supply Relay 24 +16.8...31.2 V DC 54 Output Output 23 22 Ps U/I analog output Technical data Input Input measurement range 52 Input CO 21 51 &XUUHQW VLJQDO configurable, 0…1/5/10 A AC (RMS) or DC GND 53 Supply +LJKDODUP t D t +LJKDODUPVHWSRLQW +\VWHUHVLV Input signal Input frequency Output (analogue) Output voltage [output analogue] Output current [output analogue] Load resistance voltage [output analogue] Load resistance current [output analogue] Output (digital) Type Rated switching current Max. switching voltage, AC General data Galvanic isolation Accuracy Configuration Step response time Temperature coefficient Supply voltage Insulation coordination Rated voltage Standards Impulse withstand voltage Test voltage Pollution degree Overvoltage category Current-carrying cable in feed-through hole, Diameter 10.5 mm AC: 15…700 Hz adjustable, 0...10 V, 2…10 V, 0...5 V, 1...5 V, -5…+5 V, -10...+10 V adjustable, 0...20 mA, 4...20 mA, -20…+20 mA ≥ 10 kΩ ≤ 600 Ω W!WDG 2XWSXW WDG$ODUPGHOD\ /RZDODUP W!WDG /RZDODUPVHWSRLQW W 2XWSXW W WDG$ODUPGHOD\ 7LPH WDG$ODUPGHOD\ 5HOD\GHHQHUJL]HG/('\HOORZ´2))µ 5HOD\HQHUJL]HG/('\HOORZ´21µ ',3VZLWFK6 &XUUHQWLQSXWUDQJH $ █ $ $ $ █ █ $ $ $ █ █ $ 300 V ACrms IEC 61010-1:2010, 3rd Edition, IEC 61010-2-201:2013, 1st Edition, EN 61326-1 6.4 kV (1.2/50 µs) 4 kV 2 III 1,5 / 0,5 / 2,5 113,6 / 22,5 / 117,2 WWDG +\VWHUHVLV 0HDVXULQJPHWKRG 7UXH506 $ULWKPHWLFDYHUDJH $ODUPGHOD\WLPH V V V V 0HDVXULQJUDQJH PRQLWRULQJ <HV 1R Dimensions Clamping range (nominal / min. / max.) Tiefe / Breite / Höhe Note 7LPH WDG$ODUPGHOD\ &XUUHQW VLJQDO Relay, 1 CO contact, Open or closed-circuit principle, with alarm delay time (configurable) 0 s ⁄ 2 s ⁄ 5 s ⁄ 10 s 6A 250 V 4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay < 0.5 % of end value DIP switch and potentiometer, for thresholds (overcurrent ⁄ undercurrent), delay and hysteresis < 220 ms (10...90 %) ≤ 200 ppm/K 18...30 V DC WWDG █ █ █ █ █ 2XWSXWUDQJH 9 9 9 9 9 9 P$ P$ P$ ',3VZLWFK6 █ █ █ █ █ █ █ █ █ █ █ █ $ODUPUHOD\DFWLRQ (QHUJL]HG 'HHQHUJL]HG $ODUPK\VWHUHVLV $ODUPW\SH +LJKDODUP /RZDODUP █ █ █ █ 2XWSXWHUURUDFWLRQ 8SVFDOH 'RZQVFDOH 7UDQVIHUIXQFWLRQ 1RUPDO ,QYHUVH █ █ █ 21 $&73&07$25&6 $&73&07$25&6 $&73&07$25&6$&73&075&6 Ordering data Input measurement range 0...5/10 A Input measurement range 0...20/25/30 A Input measurement range 0...40/50/60 A Input measurement range 0...40/50/60 A Note Type ACT20P-CMT-10-AO-RC-S ACT20P-CMT-30-AO-RC-S ACT20P-CMT-60-AO-RC-S ACT20P-CMT-60-RC-S Qty. 1 1 1 1 Order No. 1510470000 1510540000 1510440000 1510390000 Accessories Note 2028820000 D.33