© Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUP1010 (Portable) ■ Overview SITRANS FUP1010 clamp-on non-intrusive ultrasonic flow transmitter offers maximum versatility plus battery power for portable field use. It can operate in either WideBeam transit time or reflexor (Doppler) mode, making it suitable for virtually any liquid, even those with high aeration or suspended solids. SITRANS FUP1010 is available in single and dual channel or dual path configurations, with IP67 weatherproof enclosure. ■ Benefits • Battery power facilitates field use; the meter is easily transported from one installation to another – saving time for surveys, monitoring and temporary installations • Weatherproof enclosure can be used outdoors and left in place without concern for rain damage • Rugged plastic case enables it to withstand rough treatment that would destroy most other meters • Versatility - there is no need to change meters when operating conditions change • Easy installation; no need to cut pipe or stop flow • Minimal maintenance; external sensors do not require periodic cleaning • No moving parts to wear or foul • No pressure drop or energy loss • Wide turn-down ratio • Choice of single or dual channel models minimizes total cost • ZeroMatic Path automatically sets zero without stopping flow and reduces zero drift, even at low flow • Note that the SITRANS FUP1010 flow transmitter is not available with hazardous area approvals ■ Application SITRANS FUP1010 is suitable for a wide variety of liquid applications, including the following: • Water industry - Raw water - Potable water - Chemicals • Wastewater industry - Raw sewage - Effluent - Sludges - Mixed liquor - Chemicals • HVAC industry - Chillers - Condensers - Hot and cold water systems - Thermal energy rate and total • Power industry - Nuclear - Fossil - Hydroelectric • Processing industry - Process control - Batching - Rate indication - Volumetric and mass measurement ■ Design • IP67 Weatherproof/Impact resistant enclosure constructed of mineral reinforced copolymer polypropylene - Single channel - Dual channel/dual path ■ Function • Integral 33 button keypad and large (128 x 240 pixel) graphic display visible up to 12 m (40 ft) away • Current, voltage, frequency and RS 232 outputs (see specification section for details) • Optional current, voltage and temperature inputs (see specification section for details) • ZeroMatic Path automatically sets zero • Bi-directional flow operation • 1 MByte data logger with both site and data logger storage • English, Spanish, German, Italian and French language options • VT100 RS 232 communications Siemens FI 01 · 2016 3/343 3 © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUP1010 (Portable) ■ Technical specifications Input 3 Flow range 12 m/s ( 40 ft/s), bidirectional Flow sensitivity 0.0003 m/s ( 0.001 ft/s), flow rate independent Pipe size 6.4 mm … 9.14 m (0.25“ … 360“) Inputs, single channel • Current: 20 mA DC • Temperature: 4 wire 1 k RTD Output Outputs • Current: 20 mA DC (1 k at 30 V DC) • Voltage: 10 V DC (5 k minimum) • Status Alarm: SPDT Relays • Pulse rate: 5 kHz • VT100 RS 232 Accuracy Accuracy 0.5 % … 2 % of flow, for velocities greater than 0.3 m/s (1 ft/s) 0.0015 … 0.006 m/s ( 0.005 … 0.02 ft/s), for velocities less than 0.3 m/s (1 ft/s) Batch repeatability 0.15 % of flow, for velocities greater than 0.3 m/s (1 ft/s) 0.0005 m/s ( 0.0015 ft/s), for velocities less than 0.3 m/s (1 ft/s) Rated operation conditions Degree of protection • Weatherproof/impact resistant IP67 Liquid temperature • Standard -40 … +120 °C (-40 … +250 °F) • Optional -40 … +230 °C (-40 … +450 °F) Ambient temperature -18 … +60 °C (0 … 140 °F) Design Dimensions see SITRANS F US Clamp-on "System info and selection guide" Weight see diagrams Power supply Power Internal rechargeable battery Battery operation 7 hours Indication and operation Data logger memory 1 MByte Site storage memory 50 sites minimum Display 128 x 240 pixel LCD with backlight Keypad 33 keypad buttons with tactile feedback Language options English, Spanish, German, Italian, French Certificates and approvals Unclassified locations UL ULc Classified locations CE 3/344 EMC Directive 2014/30/EU ATEX Directive 2014/34/EU Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUP1010 (Portable) Standard MLFB for quick delivery on SITRANS FUP1010 Portable (excluding energy) Selection and Ordering data Article No. Order Code SITRANS FUP1010 (Portable) • IP67 weatherproof battery powered Article No. Order Code Selection and Ordering data SITRANS FUP1010 (Portable) • IP67 weatherproof battery powered 7ME3510- 7ME3510- 7 77 7 7 - 0 7 7 0 7 7 7 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Number of channels/ultrasonic paths Single channel Dual channel/Dual path Sensor for channel 2 (includes pipe mounting kit and spacer bar for indicated max. outer diameter listed) See "Sensor selection charts" for specifications. 1 2 no sensor A2 universal Standard flowmeter types and I/O configurations • Standard I/O - 2 x 4 ... 20 mA analog in - 2 x RTD input Sensor cables No sensor cable 1 x PVC Jacket cable, length 6 m/20 ft2) 2 x PVC Jacket cable, length 6 m/20 ft2) 1 x PVC Jacket cable, length 15 m/50 ft2) 2 x PVC Jacket cable, length 15 m/50 ft2) RTD temperature Sensor (Mounting hardware & cable included) No RTDs 1 x standard clamp-on RTD, 6 m/20 ft cable1) 2 x standard clamp-on RTD with 6 m/20 ft cable1) 1 x standard clamp-on RTD with 15 m/50 ft cable1) 2 x standard clamp-on RTD with 15 m/50 ft cable1) Battery charger options No battery charger Charger Type A for Europe (CEE7/7) Charger Type G for U.S. (NEMA 5-15P) Trackmount and straps provided up to 75 mm (3”) B3 universal Trackmount and straps provided up to 125 mm (5”) C3 universal Mounting frame and straps provided up to 300 mm (13”) D3 universal Mounting frame and straps provided up to 600 mm (24”) E2 universal Mounting frame and straps provided up to 600 mm (24”) 3) C1H (high precision) Mounting frame and straps provided up to 600 mm (24”) 3) C2H (high precision) Mounting frame and straps provided up to 600 mm (24”) D1H (high precision)3) Mounting frame and straps provided up to 600 mm (24”) D2H (high precision)3) Mounting frame and straps provided up to 600 mm (24”) Doppler to 12" with strap kit (not for IP65 (NEMA 7)) 3) D1H High temperature range 104 °C/220 °F HP C A B C D E 0 5 6 7 8 0 1 5 Sensor for channel 1 (includes pipe mounting kit and spacer bar for indicated max. outer diameter listed) See "Sensor selection charts" for specifications. no sensor A2 universal Trackmount and straps provided up to 75 mm (3”) B3 universal Trackmount and straps provided up to 125 mm (5”) C3 universal Mounting frame and straps provided up to 300 mm (13”) D3 universal Mounting frame and straps provided up to 600 mm (24”) E2 universal Mounting frame and straps provided up to 600 mm (24”) C1H (high precision)3) Mounting frame and straps provided up to 600 mm (24”) C2H (high precision)3) Mounting frame and straps provided up to 600 mm (24”) 3) D1H (high precision) Mounting frame and straps provided up to 600 mm (24”) 3) D4H (high precision) Mounting frame and straps provided up to 600 mm (24”) Doppler to 12" with strap kit (not for IP65 (NEMA 7)) D1H 3) High temperature range 104 °C/220 °F HP 7 7 77 7 - 0 7 7 0 7 7 7 3 A B C D E F M N P Q S Z Q1P Approvals: No options (UL, ULc, CE by default) Standard MLFB product offering represents 4 to 6 weeks delivery time A B 1) 2) 3) -40 ... +200 °C (-40 ... +392 °F) -40 ... +80 °C (-40 ... +176 °F) Made of stainless steel constructions. C D E F M N P R S Z P1P Siemens FI 01 · 2016 3/345 © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUP1010 (Portable) Selection and Ordering data Article No. Ord. code SITRANS FUP1010 (Portable) • IP67 weatherproof battery powered Selection and Ordering data 7ME3510- • IP67 weatherproof battery powered 7 77 7 7 - 0 7 7 0 7 7 7 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Number of channels/ultrasonic paths Single channel Dual channel/Dual path 3 Sensor cables (select proper quantity of active channels) No sensor cable IP67 (weatherproof) only 1 x PVC-jacket, length 6 m (20 ft) (for IP67 NEMA 6)2) 2 x PVC-jacket, length 6 m (20 ft) (for IP67 NEMA 6)2) 1 x PVC-jacket, length 15 m (50 ft) (for IP67 NEMA 6)2) 2 x PVC-jacket, length 15 m (50 ft) (for IP67 NEMA 6)2) RTD temperature sensor (for type 3 meter only, mounting hardware and cable included) No RTDs IP67 (weatherproof) only 1 x standard clamp-on RTD (NEMA 6) with 6 m (20 ft) cable1) 2 x standard clamp-on RTD (NEMA 6) with 6 m (20 ft) cable1) 1 x standard clamp-on RTD (NEMA 6) with 15 m (50 ft) cable1) 2 x standard clamp-on RTD (NEMA 6) with 15 m (50 ft) cable1) 1 2 C B3 universal C3 universal A D3 universal B E2 universal C D E 0 5 6 7 8 0 1 2 3 4 5 6 Trackmount and straps provided up to 75 mm (3”) Trackmount and straps provided up to 125 mm (5”) Mounting frame and straps provided up to 300 mm (13”) Mounting frame and straps provided up to 600 mm (24”) Mounting frame and straps provided up to 600 mm (24”) For the following High Precision sensors, temperature range is -40 °C to +120 °C (-40 °F to +248 °F), nominal 21 °C (70 °F): A2H (high precision) Trackmount and straps provided up to 75 mm (3”) A3H (high precision) Trackmount and straps provided up to 75 mm (3”) B1H (high precision) Trackmount and straps provided up to 125 mm (5”) B2H (high precision) Trackmount and straps provided up to 125 mm (5) 3) C1H (high precision) Mounting frame and straps provided up to 600 mm (24”) C2H (high precision)3) Mounting frame and straps provided up to 600 mm (24”) D1H (high precision)3) Mounting frame and straps provided up to 600 mm (24”) D2H (high precision)3) Mounting frame and straps provided up to 600 mm (24”) D4H (high precision)3) Mounting frame and straps provided up to 600 mm (24”) Doppler to 12“ with chain kit High temperature sensor size 2 for up to 230 °C (446 °F) (30 to 200 mm diam. (1.18 to 7.67 inch diam.)) High temperature sensor size 3 for up to 230 °C (446 °F) (150 to 610 mm diam. (5.90 to 24 inch diam.)) High temperature sensor size 4 for up to 230 °C (446 °F) (400 to 1200 mm diam. (15.75 to 47.25 inch diam.)) 3/346 Siemens FI 01 · 2016 7ME35107 7 77 7 - 0 7 7 0 7 7 7 no sensor A2 universal Battery charger options no battery charger Charger Type A for Europe (CEE7/7) Charger Type C for Australia (AS3112) Charger Type D for U.K. (BS1363) Charger Type J for Japan (JIS8303) Charger Type G for U.S. (NEMA 5-15P) Charger Type L for Switzerland (SEV1011) Ord. code Sensor for channel 1 Including pipe mounting tracks for sizes A & B sensors indented for pipe with a OD less than 125 mm (5") and mounting frame/spacer bars for sizes C, D & E sensors. Straps provided are for the indicated maximum OD listed below. Strap kits are available to accommodate larger pipes (refer to spare part list). Refer to "Sensor Selection Charts" for the sensor suitability of pipe size and wall thickness. Standard flowmeter types and I/O configurations • Standard I/O - Reflexor capable - Graphic display - 2 x 0 ... 10 V - 2 x 4 ... 20 mA - 2 x pulse outputs - 4 x status logic - 2 x 4 ... 20 mA analog in - 1 x RTD per channel Article No. SITRANS FUP1010 (Portable) A B C D E F H J K L M N P Q R S Z P1A Z P1B Z P1C © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUP1010 (Portable) Selection and Ordering data Article No. Ord. code SITRANS FUP1010 (Portable) • IP67 weatherproof battery powered Article No. Selection and Ordering data Ord. code SITRANS FUP1010 (Portable) • IP67 weatherproof battery powered 7ME3510- 7ME3510- 7 77 7 7 - 0 7 7 0 7 7 7 7 7 77 7 - 0 7 7 0 7 7 7 Sensor for channel 1 (continued) Sensor for channel 2 (continued) For the following High Precision sensors, temperature range is -40 °C to +120 °C (-40 °F to +248 °F), nominal 65 °C (150 °F): B1H (high temperature range HP) B2H (high temperature range HP) C1H (high temperature range HP) C2H (high temperature range HP) D1H (high temperature range HP) D2H (high temperature range HP) D4H (high temperature range HP) High temperature sensor size 2 for up to 230 °C (446 °F) (30 to 200 mm diam. (1.18 to 7.67 inch diam.)) Z Q1A High temperature sensor size 3 for up to 230 °C (446 °F) (150 to 610 mm diam. (5.90 to 24 inch diam.)) Z Q1B High temperature sensor size 4 for up to 230 °C (446 °F) (400 to 1200 mm diam. (15.75 to 47.25 inch diam.)) Z Q1C Z Z Z Z Z Z Z Q1K Q1 L Q1M Q1N Q1P Q1Q Q1R Z Z Z Z Z Z Z P1K P1L P 1M P1N P1P P1Q P1R Sensor for channel 2 (includes pipe mounting kit and spacer bar for indicated max. outer diameter listed) See "Sensor selection charts" for specifications. no sensor A2 universal B3 universal C3 universal D3 universal E2 universal Trackmount and straps provided up to 75 mm (3”) Trackmount and straps provided up to 125 mm (5”) Mounting frame and straps provided up to 300 mm (13”) Mounting frame and straps provided up to 600 mm (24”) Mounting frame and straps provided up to 600 mm (24”) For the following High Precision sensors, temperature range is -40 °C to +120 °C (-40 °F to +248 °F), nominal 21 °C (70 °F): A2H (high precision) Trackmount and straps provided up to 75 mm (3”) A3H (high precision) Trackmount and straps provided up to 75 mm (3”) B1H (high precision) Trackmount and straps provided up to 125 mm (5”) B2H (high precision) Trackmount and straps provided up to 125 mm (5") C1H (high precision)3) Mounting frame and straps provided up to 600 mm (24”) C2H (high precision)3) Mounting frame and straps provided up to 600 mm (24”) D1H (high precision)3) Mounting frame and straps provided up to 600 mm (24”) 3) D2H (high precision) Mounting frame and straps provided up to 600 mm (24”) 3) D4H (high precision) Mounting frame and straps provided up to 600 mm (24”) Doppler to 12“ with chain kit A B C D For the following High Precision sensors, temperature range is -40 °C to +120 °C (-40 °F to +248 °F), nominal 65 °C (150 °F): B1H (high temperature range HP) B2H (high temperature range HP) C1H (high temperature range HP) C2H (high temperature range HP) D1H (high temperature range HP) D2H (high temperature range HP) D4H (high temperature range HP) Approvals: No options (UL, ULc, CE by default) 1) -40 ... +200 °C (-40 ... +392 °F) -40 ... +80 °C (-40 ... +176 °F) 3) Made of stainless steel constructions. 2) E Selection and Ordering data F H Article No. Operating Instructions for SITRANS FUP1010 English IP67 Weatherproof A5E02951522 German IP67 Weatherproof A5E02951534 This device is shipped with a Quick Start Guide and a CD containing further SITRANS F literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation J K L M N P Q R S Siemens FI 01 · 2016 3/347 3 © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUP1010 (Portable) Selection and Ordering data Order code Further designs Application example Please add "-Z" to Article No. and specify Order code(s). A general survey portable flowmeter is required for pipes sizes ranging from 76 ... 500 mm (3" ... 20") with both cast iron and steel material. Doppler may be required as liquid may be moderately aerated. Languages (Meter and Documentation), English (default). All languages now come standard in all flowmeters Wet flow transfer calibration (priced on request) Requires language support for German. 6 point calibration 2/water (Price per channel) 3 • 2SS40 pipe • 3CS40 pipe • 4CS40 pipe • 4SS40 pipe D01 D02 D03 D04 • 6CS40 pipe • 6SS40 pipe • 6CS120 pipe • 8CS40 pipe D05 D06 D07 D08 • 8SS40 pipe • 8CS120 pipe • 10CS Standard pipe • 10CS40 pipe D09 D10 D11 D12 • 10SS40 pipe • 12CS Standard pipe • 12CS40 pipe • 14CS30 pipe D13 D14 D15 D16 • 14CS40 pipe • 16CS Standard pipe • 16CS40 pipe • 18CS Standard pipe D17 D18 D19 D20 • 20CS20 pipe • 20CS30 pipe • 24CS Standard pipe • 24CS20 pipe D21 D22 D23 D24 • 24CS30 pipe • 30CS Standard pipe • 36CS Standard pipe • Other pipe, other liquid, additional points, witness D25 D26 D27 Y28 1x Insertion RTD with thermowell and lagging 2x Insertion RTD with thermowell and lagging M1A M1B Tag name plate • Stainless steel tag with 3.2 mm (0.13 inch) character size (68 characters max.) ■ MLFB example Y19 MLFB Article No.: 7ME3510-2CB01-0DE0-Z B10 Article No. Ord. code 7 M E 3 5 1 7 - 7 777 7 - 0 7 7 0 7 7 7 Selection and Ordering data SITRANS FUP1010 meter family 0 IP67 weatherproof 2 Dual channel C Portable I/O with Doppler capable, temperature B 1 x PVC-Jacket, length 6 m (20 ft) 0 No RTDs required 1 Charger Type A for Europe (CEE7/7) D Sensor for DN 50 ... DN 300 (2“ ... 12“) pipes E Sensor for DN 200 ... DN 600 (8“ ... 24“) pipes Universal sensor selection chart IP68 Based on pipe size (all pipe materials) Pipe size Order Code Outer diameter range (mm) Outer diameter range (inch) A2 B min. max. min. max. 12.7 50.8 0.5 B3 2 C 19 127 0.75 5 C3 D 51 305 2 12 D3 E 203 610 8 24 E2 F 254 6096 10 249 High precision sensor selection chart IP68 Based on pipe wall thickness (steel pipes only) Pipe Wall Order Code Pipe Wall [mm] Pipe Wall [inch] min. max. min. max. A1H G 0.64 1.02 0.025 0.04 A2H H 1.02 1.52 0.04 0.06 A3H J 1.52 2.03 0.06 0.08 B1H K 2.03 3.05 0.08 0.12 B2H L 3.05 4.06 0.12 0.16 C1H1) M 4.06 5.84 0.16 0.23 C2H1) N 5.84 8.13 0.23 0.32 D1H1) P 8.13 11.18 0.32 0.44 D2H1) Q 11.18 15.75 0.44 0.62 D4H1) R 15.75 31.75 0.62 1.25 1) 3/348 Siemens FI 01 · 2016 Made of stainless steel constructions.