© Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUE1010 (Energy) ■ Overview ■ Application SITRANS FUE1010 is ideally suited to thermal energy/power industry applications, including: • Chilled water sub-metering • Hot water sub-metering • Condenser water • Glycol • Thermal storage • Lake source cooling ■ Design SITRANS FUE1010 is a highly accurate clamp-on non-intrusive ultrasonic flow transmitter for revenue grade thermal energy sub-metering and energy efficiency distribution monitoring, with a real time coefficient of performance (COP) for HVAC systems. SITRANS FUE1010 is available in single and dual channel or dual path configurations, with your choice of IP65 (NEMA 4X) dedicated wall mount or IP40 (NEMA 1) portable enclosures. ■ Benefits • Measures energy rate and total consumption with highest accuracy available • Accurately measures at both low flow rates and low differential temperatures • Easy installation; no need to cut pipe or stop flow • Minimal maintenance; external sensors do not require periodic cleaning • No moving parts to foul or wear • No pressure drop or energy loss • Wide turn-down ratio • Choice of single or dual channel/dual path or dual mode operation: - Dual channel operation reduces the cost for the system on a per channel measurement basis and permits measuring hot and chilled water lines at the same time - Dual path capability insures high flow measurement accuracy on installations with less than desirable piping runs • Ability to operate in either Wide-Beam Transit-time or reflexor (Doppler) mode for applications with high aeration • ZeroMatic Path automatically sets zero without stopping flow and reduces zero drift, even at low flow SITRANS FUE1010 is available in three configurations: • IP65 (NEMA 4X) wall mount enclosure constructed of fiberglass reinforced polyester with stainless steel hardware and polyester keypad - Single channel - Dual channel/dual path • IP40 (NEMA 1) Portable impact resistant enclosure constructed of mineral reinforced copolymer polypropylene - Dual channel/dual path ■ Function • Flow transmitter has an integral 33 button keypad and large (128 x 240 pixel) graphic display visible up to 12 m (40 ft) away • 4-wire 1000 platinum RTD’s for supply and return temperature measurements are precision matched to within 0.01 °C (0.02 °F) • Temperature is factory calibrated with built-in field calibrator. • Built-in energy/BTU mode • Detection of aeration and cavitation caused by worn or damaged impellers, misaligned shafts, etc. • Reverse flow and empty pipe detection • Chiller efficiency analysis: accepts an independent analog input representing kW usage for calculation of the following functions which can be selected for data logging or output purposes: - Cooling load (kW/ton) - Coefficient of performance (COP) - Energy efficiency ratio (EER) • Optional current inputs • Digital communication options: - HART, BACnet MSTP/BACnet IP, Modbus RTU & TCP/IP, Ethernet IP, Johnson N2 (IP65, NEMA 4X only) - VT100 RS 232 serial communications (Portable and NEMA 4X) • ZeroMatic Path automatically sets zero • Bi-directional flow operation • 1 MByte data logger with both site and data logger storage • English, Spanish, German, Italian and French language options Siemens FI 01 · 2016 3/351 3 © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUE1010 (Energy) ■ Technical specifications Input Indication and operation Flow range 3 0 … 12 m/s (0 … 40 ft/s), bi-directional Data logger memory 1 Mbyte of storage Display 128 x 240 pixel LCD with backlight Flow sensitivity 0.0003 m/s (0.001 ft/s) Pipe size 6.4 mm … 9.14 m (0.25“ … 360“) Keypad Inputs per channel • Current: 20 mA • Temperature: 4 wire 1 k RTD • Totalizer commands (clear/hold) 33 keypad buttons with tactile feedback Language options English, Spanish, German, Italian, French Output Standard outputs Optional outputs • Current: 20 mA DC (1 k at 30 V DC) • Voltage: 10 V DC (5 k minimum) • Status Alarm: SPDT Relays • Form C relays • Pulse rate: 5 kHz • VT100 RS 232 • Expanded I/Os (4 additional 4 ... 20 mA outputs) with form C relays • HART, BACnet MSTP/BACnet IP, Modbus RTU & TCP/IP, Ethernet IP, Johnson N2 (IP65, NEMA 4X only) Accuracy Accuracy 0.5 % ... 1.0 % of flow, for velocities greater than 0.3 m/s (1 ft/s) 0.0015 ... 0.003 m/s ( 0.005 ... 0.01 ft/s), for velocities less than 0.3 m/s (1 ft/s) Batch repeatability 0.15 % of flow, for velocities greater than 0.3 m/s (1 ft/s) 0.0005 m/s ( 0.0015 ft/s), for velocities less than 0.3 m/s (1 ft/s) Rated operation conditions Degree of protection Wall mount enclosure: IP65 (NEMA 4X) Portable enclosure: IP40 (NEMA 1) Liquid temperature • Standard -40 … +120 °C (-40 … +250 °F) • Optional -40 … +230 °C (-40 … +450 °F) Sensor temperature • Standard -40 … +120 °C (-40 … +250 °F) • Optional -40 … +232 °C (-80 … +450 °F) Ambient temperature -18 ... +60 °C (0 ... 140 °F) Design Dimensions see SITRANS F US Clamp-on "System info and selection guide" Weight see diagrams Power supply Dedicated 90 … 240 V AC, 50 ... 60 Hz, 30 VA or 9 ... 36 V DC Portable enclosure Rechargeable battery 3/352 Siemens FI 01 · 2016 Certificates and approvals Dedicated enclosures FM and CSA ratings • Transmitter NI Class I, Div 2 S Class II, Div 2 • Sensor I.S. Class I, II, Div 1 CE EMC Directive 2014/30/EU ATEX Directive 2014/34/EU Portable enclosures UL ULc CE EMC Directive 2014/30/EU ATEX Directive 2014/34/EU © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUE1010 (Energy) Standard MLFB for quick delivery on SITRANS FUE1010 (Energy system) Selection and Ordering data SITRANS FUE1010 (Energy) Article No. Order code 7 M E 3 5 0 7 - 7 77 7 7 - 0 7 7 7 7 7 7 7 7 7 + 7 7 7 + 7 7 7 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Design Dedicated IP65 (NEMA 4X) wall mount Portable IP40 (NEMA 1) Battery powered Number of channels/ultrasonic paths Dedicated meters Single channel Portable meters Dual channel/Dual path Flowmeter functions and I/O configurations • Portable Standard I/O - Reflexor capability - Graphic display - 2 x 0 ... 10 V - 2 x 4 ... 20 mA (active) - 2 x 0 ... 5 kHz pulse output (TTL) - 4 x status logic (TTL) - Energy efficiency COP/EER output - 4 x logic inputs (totalizer control, TTL) - 2 x 4 ... 20 mA analog input - 2 x Pt100 RTD per channel • Dedicated Standard I/O - Reflexor capability - Graphic display - 2 x 0 ... 10 V - 2 x 4 ... 20 mA (active) - 2 x 0 ... 5 kHz pulse output (TTL) - 4 x relay form C type - Energy efficiency COP/EER output - 4 x logic inputs (totalizer control, TTL) - 4 x 4 ... 20 mA analog input (Single channel only) - 2 x 4 ... 20 mA analog input (Dual channel only) - 2 x Pt100 RTD per channel Meter power options 90 ... 240 V AC (Dedicated only) Charger Type A for Europe (CEE7/7) Charger Type K for U.S. (NEMA 5-15P) No charger Communication options VT100 RS 232 RTD temperature sensor pair (includes mounting hardware for pipes above 1.5“ outer diameter) No RTDs (Note: Temperature input is required for Energy systems) 1 x Pair Std clamp-on RTD (NEMA 4X only)3) 2 x Pair Std clamp-on RTD (For Dual Channel NEMA 4X only)3) 1 x Pair Std clamp-on RTD (For NEMA 12 Portable)3) 2 x Pair Std clamp-on RTD (For Dual Channel NEMA 1 Portable)3) 1 x Insertion RTD with Thermowell and Lagging3) 2 x Insertion RTD with Thermowell and Lagging3) Sensor for channel 1 (includes pipe mounting kit and spacer bar for indicated max. OD listed) See "Sensor selection charts" for specifications. no sensor A2 universal Trackmount and straps provided up to 75 mm (3") B3 universal Trackmount and straps provided up to 125 mm (5") C3 universal5) Mounting frame and straps provided up to 300 mm (13") D3 universal5) Mounting frame and straps provided up to 600 mm (24") E2 universal5) Mounting frame and straps provided up to 1200 mm (48")1)4) C1H (high precision)5) Mounting frame and straps provided up to 600 mm (24")4) C2H (high precision)5) Mounting frame and straps provided up to 600 mm (24")4) D1H (high precision)5) Mounting frame and straps provided up to 1200 mm (48")4) D2H (high precision)5) Mounting frame and straps provided up to 1200 mm (48")4) Doppler to 12" with strap kit (not for IP65 (NEMA7)), for up to 121 °C (250 °F) 5) D1H High temperature range 104 °C/220 °F HP2) 0 K02 + K0 2 + R02 2 K01 + K0 1 + R01 3 1 4 C F A C G J 0 0 1 2 3 4 9 9 M1A M1B A B C D E F M N P Q S Z P1P Siemens FI 01 · 2016 3/353 © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUE1010 (Energy) Selection and Ordering data SITRANS FUE1010 (Energy) 3 Sensor for channel 2 (includes pipe mounting kit and spacer bar for indicated max. OD listed) See "Sensor selection charts" for specifications. no sensor A2 universal Trackmount and straps provided up to 75 mm (3") B3 universal Trackmount and straps provided up to 125 mm (5") C3 universal5) Mounting frame and straps provided up to 300 mm (13") D3 universal5) Mounting frame and straps provided up to 600 mm (24") E2 universal5) Mounting frame and straps provided up to 1200 mm (48")1)4) C1H (high precision)5) Mounting frame and straps provided up to 600 mm (24")4) C2H (high precision)5) Mounting frame and straps provided up to 600 mm (24")4) D1H (high precision)5) Mounting frame and straps provided up to 1200 mm (48")4) D4H (high precision)5) Mounting frame and straps provided up to 1200 mm (48")4) Doppler to 12" with strap kit (not for IP65 (NEMA7)), for up to 121 °C (250 °F) D1H5) High temperature range 104 °C/220 °F HP2) Approvals 1) 2) 3) 4) 5) UL/Portable FM, CSA, CE, Dedicated Article No. Order code 7 M E 3 5 0 7 - 7 77 7 7 - 0 7 7 7 7 7 7 7 7 7 + 7 7 7 + 7 7 7 A B C D E F M N P R S Z Q1P 0 1 Supplied spacer bar supports pipes up to 1050 mm (42 inch). For pipes larger than 1050 mm (42 inch) purchase also, spare part 7ME3960-0MS40 (1012BN-4) Supplied spacer bar supports pipes up to 750 mm (30 inch). For pipes larger than 750 mm (30 inch) purchase also, spare part 7ME3960-0MS40 (1012BN-4) Requires two R** cables per one RTD pair 600 mm (24") for portable systems only Made with stainless steel constructions. Standard MLFB product offering represents 4 to 6 weeks delivery time For sensor and RTD cables for quick delivery see tables at end of section 3/354 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUE1010 (Energy) Selection and Ordering data Article No. Ord. code SITRANS FUE1010 (Energy) • Dedicated IP65 (NEMA 4X) wall mount • Portable IP40 (NEMA 1) Battery powered Article No. Selection and Ordering data 7ME3500- • Dedicated IP65 (NEMA 4X) wall mount 7ME3500- 7ME3502- • Portable IP40 (NEMA 1) Battery powered 7ME3502- 7 7 77 7 - 0 7 7 7 7 7 7 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. 7 7 77 7 - 0 7 7 7 7 7 7 RTD temperature sensor (includes mounting hardware for pipes above 1.5“ outer diameter) Number of channels/ultrasonic paths Dedicated meter Dedicated meter Single channel Dual channel/Dual path 1 2 Portables Dual channel/Dual path 4 No RTDs (Note: temperature input is required for energy system) 1 x pair standard clamp-on RTD (NEMA 4X only)3) 2 x pair standard clamp-on RTD (for dual channel NEMA 4X only)3) 1 x pair standard clamp-on RTD (NEMA 1 Portable)3) 2 x pair standard clamp-on RTD (for dual channel NEMA 1 Portable)3) 1 x Insertion style RTD with thermowell and lagging3) 2 x Insertion style RTD with thermowell and lagging3) Flowmeter functions and I/O configurations • Portable Standard I/O - Reflexor capability - Graphic display - 2 x 0 ... 10 V - 2 x 4 ... 20 mA (active) - 2 x 0 ... 5 kHz pulse output (TTL) - 4 x status logic (TTL) - Energy efficiency COP/EER output - 4 x logic inputs (totalizer control, TTL) - 2 x 4 ... 20 mA analog input - 2 x Pt100 RTD per channel C • Dedicated Standard I/O - Reflexor capability - Graphic display - 2 x 0 ... 10 V - 2 x 4 ... 20 mA (active) - 2 x 0 ... 5 kHz pulse output (TTL) - 4 x relay C type - Energy efficiency COP/EER output - 4 x logic inputs (totalizer control, TTL) - 4 x 4 ... 20 mA analog input (Single channel only) - 2 x 4 ... 20 mA analog input (Dual channel only) - 2 x Pt100 RTD per channel F • Dedicated extended I/O includes Standard I/O plus - 4 x 4 ... 20 mA outputs (passive) Z 3 0 1 2 3 4 9 M1A 9 M1B Sensor for channel 1 Including pipe mounting tracks for sizes A & B sensors indented for pipe with a OD less than 125 mm (5") and mounting frame/spacer bars for sizes C, D & E sensors. Straps provided are for the indicated maximum OD listed below. Strap kits are available to accommodate larger pipes (refer to spare part list). Refer to "Sensor Selection Charts" for the sensor suitability of pipe size and wall thickness. No sensor A2 universal B3 universal C3 universal5) J1B D3 universal5) E2 universal5) Meter power options 90 ... 240 V AC (Dedicated only) 9 ... 36 V DC (Dedicated only) Charger Type A for Europe (CEE7/7) Charger Type C for Australia (AS3112) Charger Type D for U.K. (BS1363) Charger Type J for Japan (JIS8303) Charger Type K for U.S. (NEMA 5-15P) Charger Type L for Switzerland (SEV1011) No Charger A B C D E F G H J External 4 hours battery with US plug for Portable Z K1A External 4 hours battery with European plug for Portable Z K1B Trackmount and straps provided up to 75 mm (3”) Trackmount and straps provided up to 125 mm (5”) Mounting frame and straps provided up to 300 mm (13”) Mounting frame and straps provided up to 600 mm (24”) Mounting frame and straps provided up to 1200 mm (48”)1)4) A B C D E F For the following High Precision sensors, temperature range is -40 °C to +120 °C (-40 °F to +248 °F), nominal 21 °C (70 °F): Communication options VT100 RS 232 7ME3500 only; HART, BACnet MSTP/BACnet IP, Modbus RTU/TCPIP, Ethernet IP, Johnson N2 Ord. code SITRANS FUE1010 (Energy) For other temperature ranges please see spare parts list. A2H (high precision) Trackmount and straps provided up to 75 mm (3”) A3H (high precision) Trackmount and straps provided up to 75 mm (3”) B1H (high precision) Trackmount and straps provided up to 125 mm (5”) H J K 0 3 Siemens FI 01 · 2016 3/355 © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUE1010 (Energy) Selection and Ordering data Article No. Ord. code SITRANS FUE1010 (Energy) • Dedicated IP65 (NEMA 4X) wall mount • Portable IP40 (NEMA 1) Battery powered Selection and Ordering data 7ME3500- • Dedicated IP65 (NEMA 4X) wall mount 7ME3500- 7ME3502- • Portable IP40 (NEMA 1) Battery powered 7ME3502- 7 7 77 7 - 0 7 7 7 7 7 7 3 Sensor for channel 1 (continued) B2H (high precision) Trackmount and straps provided up to 125 mm (5") C1H (high precision)5) Mounting frame and straps provided up to 600 mm (24”)4) 5) C2H (high precision) Mounting frame and straps provided up to 600 mm (24”)4) 5) D1H (high precision) Mounting frame and straps provided up to 1200 mm (48”)2)4) 5) D2H (high precision) Mounting frame and straps provided up to 1200 mm (48”)2)4) D4H (high precision)5) Mounting frame and straps provided up to 1200 mm (48”)2)4) to 12“ with strap kit, Doppler for up to 121 °C (250 °F) L M N P Q R S Z P1A High temperature sensor size 3 for up to 230 °C (446 °F) (150 ... 610 mm diam. (5.90 ... 24 inch diam.)) Z P1B High temperature sensor size 4 for up to 230 °C (446 °F) (400 ... 1200 mm diam. (15.75 ... 47.25 inch diam.)) Z P1C Z Z Z Z Z Z Z P1K P1L P 1M P1N P1P P1Q P1R Sensor for channel 2 (includes pipe mounting kit for indicated max. outer diameter listed) See "Sensor selection charts" for specifications. no sensor A2 universal B3 universal C3 universal D3 universal E2 universal 3/356 Trackmount and straps provided up to 75 mm (3”) Trackmount and straps provided up to 125 mm (5”) Mounting frame and straps provided up to 300 mm (13”) Mounting frame and straps provided up to 600 mm (24”) Mounting frame and straps provided up to 1200 mm (48”)1)4) Siemens FI 01 · 2016 Ord. code 7 7 77 7 - 0 7 7 7 7 7 7 Sensor for channel 2 (continued) High temperature sensor size 2 for up to 230 °C (446 °F) (30 ... 200 mm diam. (1.18 ... 7.67 inch diam.)) For the following High Precision sensors, temperature range is -40 °C to +120 °C (-40 °F to +248 °F), nominal 65 °C (150 °F): B1H (high temperature range HP) B2H (high temperature range HP) C1H (high temperature range HP)5) C2H (high temperature range HP)5) D1H (high temperature range HP)2)5) D2H (high temperature range HP)2)5) D4H (high temperature range HP)2)5) Article No. SITRANS FUE1010 (Energy) A B C D E For the following High Precision sensors, temperature range is -40 °C to +120 °C (-40 °F to +248 °F), nominal 21 °C (70 °F): A2H (high precision) Trackmount and straps provided up to 75 mm (3”) A3H (high precision) Trackmount and straps provided up to 75 mm (3”) B1H (high precision) Trackmount and straps provided up to 125 mm (5”) B2H (high precision) Trackmount and straps provided up to 125 mm (5") C1H (high precision)5) Mounting frame and straps provided up to 600 mm (24”)4) C2H (high precision)5) Mounting frame and straps provided up to 600 mm (24”)4) 5) D1H (high precision) Mounting frame and straps provided up to 1200 mm (48”)2)4) 5) D2H (high precision) Mounting frame and straps provided up to 1200 mm (48”)2)4) 5) D4H (high precision) Mounting frame and straps provided up to 1200 mm (48”)2)4) to 12“ with strap kit, Doppler for up to 121 °C (250 °F) H J K L M N P Q R S High temperature sensor size 2 for up to 230 °C (446 °F) (30 ... 200 mm diam. (1.18 ... 7.67 inch diam.)) Z Q1A High temperature sensor size 3 for up to 230 °C (446 °F) (150 to 610 mm diam. (5.90 to 24 inch diam.)) Z Q1B High temperature sensor size 4 for up to 230 °C (446 °F) (400 to 1200 mm diam. (15.75 to 47.25 inch diam.)) Z Q1C Z Z Z Z Z Z Z Q1K Q1 L Q1M Q1N Q1P Q1Q Q1R For the following High Precision sensors, temperature range is -40 °C to +120 °C (-40 °F to +248 °F), nominal 65 °C (150 °F): B1H (high temperature range HP) B2H (high temperature range HP) C1H (high temperature range HP)5) C2H (high temperature range HP)5) D1H (high temperature range HP)2)5) D2H (high temperature range HP)2)5) D4H (high temperature range HP)2)5) Approvals FM/CSA/CE Dedicated UL/ULc/CE Portable 1 0 1) Supplied spacer bar supports pipes up to 1050 mm (42 inch). For pipes larger than 1050 mm (42 inch) purchase also, spare part 7ME3960-0MS40 (1012BN-4). 2) Supplied spacer bar supports pipes up to 750 mm (30 inch). For pipes larger than 750 mm (30 inch) purchase also, spare part 7ME3960-0MS40 (1012BN-4). 3) Requires two R** cables per one RTD pair 4) 600 mm (24") for portable systems only 5) Made with stainless steel construction. F © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUE1010 (Energy) Selection and Ordering data Order code Further designs ■ MLFB example Application example Please add "-Z" to Article No. and specify Order code(s). Cable assembly for sensors (add for # of channels) See "Sensor cable selection chart" K.. Cable assembly for RTDs (add for # of RTDs) See "RTD cable selection chart" R.. Cable termination kit (for one cable pair) dedicated only • Termination for standard, plenum and armored sensor cable • Termination for submersible sensor cable T01 • RTD cable termination kit for standard RTD • RTD cable termination kit for submersible RTD • Insert RTD cable termination kit • Cable gland kit T21 T31 T41 T51 T11 A dedicated clamp-on energy meter is required for two separate return lines. Both will use clamp-on RTDs for the supply and return lines. AC power is available and data access will be via Modbus communication. Pipe 1 is a DN150 (6") schedule 40 carbon steel line Pipe 2 is a DN 300 (12") ductile iron line MLFB Article No.: 7ME3500-2FA30-2NE0-Z K03 + K05 + R03 + R05 + R02 + R03 Selection and Ordering data SITRANS FUE1010 meter family Wet flow transfer calibration (priced on request) IP65 (NEMA 4X) enclosure 6 point calibration 2/water (Price per channel) Dual channel • 2SS40 pipe • 3CS40 pipe • 4CS40 pipe • 4SS40 pipe Dedicated Type 1 I/O option D01 D02 D03 D04 • 6CS40 pipe • 6SS40 pipe • 6CS120 pipe • 8CS40 pipe D05 D06 D07 D08 • 8SS40 pipe • 8CS120 pipe • 10CS Standard pipe • 10CS40 pipe D09 D10 D11 D12 • 10SS40 pipe • 12CS Standard pipe • 12CS40 pipe • 14CS30 pipe D13 D14 D15 D16 • 14CS40 pipe • 16CS Standard pipe • 16CS40 pipe • 18CS Standard pipe D17 D18 D19 D20 • 20CS20 pipe • 20CS30 pipe • 24CS Standard pipe • 24CS20 pipe D21 D22 D23 D24 • 24CS30 pipe • 30CS Standard pipe • 36CS Standard pipe • Other pipe, other liquid, additional points, witness D25 D26 D27 Y28 Tag name plate • Stainless steel tag with 3.2 mm (0.13 inch) character size (68 characters max.) Y19 3 Article No. Ord. code 7 M E 3 5 0 7 - 7 777 0 - 7 7 7 7 7 7 7 0 2 F A 90 ... 230 V AC power option 3 Modbus option 2 2 pairs of clamp-on RTDs N Sensor code for 6" pipe E Sensor code for 12" pipe 0 No approval required 30 m (100 ft) sensor cable for channel 1 K03 61 m (200 ft) sensor cable for channel 1 K05 30 m (100 ft) cable for RTD 1 R03 61 m (200 ft) cable for RTD 2 R05 15 m (50 ft) cable for RTD 3 R02 30 m (100 ft) cable for RTD 4 R03 Order code Selection and Ordering data Operating Instructions for SITRANS FUE1010 English NEMA 4X Wall mount A5E03086491 German NEMA 4X Wall mount A5E03086492 English IP40 NEMA 1 Battery powered A5E02951524 German IP40 NEMA 1 Battery powered A5E02951536 This device is shipped with a Quick Start Guide and a CD containing further SITRANS F literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Siemens FI 01 · 2016 3/357 © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUE1010 (Energy) 3 Universal sensor selection chart IP68 RTD cable (single) selection chart Based on pipe size (all pipe materials) RTD cable codes for length and type Pipe size Order Code Outer diameter range (mm) Outer diameter range (inch) A2 B min. max. min. max. 12.7 50.8 0.5 2 B3 C 19 127 0.75 5 C3 D 51 305 2 12 D3 E 203 610 8 24 E2 F 254 6096 10 249 High precision sensor selection chart IP68 Pipe Wall [mm] Pipe Wall [inch] min. max. min. max. A1H G 0.64 1.02 0.025 0.04 A2H H 1.02 1.52 0.04 0.06 A3H J 1.52 2.03 0.06 0.08 B1H K 2.03 3.05 0.08 0.12 B2H L 3.05 4.06 0.12 0.16 C1H1) M 4.06 5.84 0.16 0.23 C2H1) N 5.84 8.13 0.23 0.32 D1H1) P 8.13 11.18 0.32 0.44 D2H1) Q 11.18 15.75 0.44 0.62 D4H1) R 15.75 31.75 0.62 1.25 1) Made with stainless steel construction. Sensor cable (single pair) selection chart Sensor cable codes for length and type options Cable length m Standard (PVC (ft) jacket) Submersible1) (polyethylene jacket) -40…+80 °C Plenum Rated (teflon jacket) Armored1) -40…+80 °C -40…+200 °C -40…+80 °C (-40…+176 °F) (-40…+176 °F) (-40…+392 °F) (-40…+176 °F) Order code 6 (20) K012) K11 K21 K31 15 (50) K02 K122) K22 K322) 2) 30 (100) K03 2) K13 K23 K33 46 (150) K042) K14 K24 K34 61 (200) K05 K15 K25 K35 91 (300) K062) K16 K26 K36 1) 2) Submersible and armored sensor cable is not available for portable versions. Standard MLFB for quick delivery 3/358 Siemens FI 01 · 2016 Insert1) -40 ... +200 °C (-40 … +392 °F) Order code R012) R21 15 (50) R022) R22 30 (100) R032) R23 46 (150) R04 R24 61 (200) R05 R25 91 (300) R06 R26 2) Order Code Standard (teflon wrapped) -40 ... +200 °C (-40 … +392 °F) 6 (20) 1) Based on pipe wall thickness (steel pipes only) Pipe Wall Cable length m (ft) Submersible RTD cable is not available for portable versions. Standard MLFB for quick delivery