SITRANS FUH1010 Clamp-on flow meter catalog sheet

© Siemens AG 2016
Flow Measurement
SITRANS F US Clamp-on
SITRANS FUH1010 (Oil)
■ Overview
■ Application
Interface detection
• Precise identification of interfaces on multi-liquid pipelines
• Product identification
• Density indication
Precision volume
• Applications with multiple liquids having a wide viscosity
range
• Automatic gross volume compensation due to viscosity
changes
SITRANS FUH1010 clamp-on non-intrusive ultrasonic flowmeter
is ideal for applications carrying crude oil, refined petroleum or
liquefied gas.
SITRANS FUH1010 has three application areas: Interface detectors, precision volume or standard volume flowmeters.
■ Benefits
For all SITRANS FUH1010 products
• Easy installation; no need to cut pipe or stop flow
• Minimal maintenance; external sensors do not require periodic cleaning
• No moving parts to foul or wear
• No pressure drop or energy loss
• Wide turn-down ratio, 30:1
• Choice of single, dual, or optional, three or four path versions.
- Single path version reduces initial investment
- Two or optional three and four path versions provide higher
accuracy, especially where limited straight run or poor flow
profile exists
• WideBeam technology
- Helps provide improved accuracy over a wide range of liquid conditions and flow rates
- Accommodates pipelines transporting multiple liquid products
• ZeroMatic Path automatically corrects for zero drift without
stopping flow
Interface detection
• Outputs liquid density and API as a direct replacement for intrusive densitometers
• Exceptional repeatability is maintained, independent of
changes in temperature, pressure or viscosity
• No need for straight run
Standard volume (High end system)
• Standard (net) volume flow measurement
• Suitable for use in leak detection systems
• Mass flow output measurement
• Interface detection
• "Pig" detection
• Chemical and petrochemical processing
■ Design
SITRANS FUH1010 is available in three enclosures:
• IP65 (NEMA 4X) wall mount enclosure constructed of fiberglass reinforced polyester with stainless steel hardware and
polyester keypad
- Single path
- Dual path
- Optional four path
• IP66 (NEMA 7) wall mount explosionproof enclosure constructed of cast aluminum, stainless steel hardware, with glass
window
- Single path
- Dual path
- Four path (optional)
• There are 2 types of mounting assemblies
- Aluminum mounting frames (default)
- Stainless steel weld seal (optional)
■ Function
• IP65 (NEMA 4X) and IP66 (NEMA 7) flowmeters have integral
33 button keypads and large (128 x 240 pixel) graphic displays visible up to 12 m (40 ft) away
• Current, voltage, status alarm, frequency outputs and communications HART, BACnet MSTP/BACnet IP, Modbus RTU &
TCP/IP, Ethernet IP, Johnson N2, VT100 RS 232 (see specification section for details)
• Analog inputs (see specification section for details)
• ZeroMatic Path automatically corrects for zero drift
• Bidirectional flow operation
• 1 MByte data logger with both site and data logger storage
• English, Spanish, German, Italian and French language options
Precision volume
• Moderate cost
• Precise measurement is maintained with automatic "Reynolds
Number" compensation for temperature and viscosity
changes.
Standard volume (High end system)
• Exceptional repeatability is maintained, independent of
changes in temperature, density or viscosity
• Batch interface and product quality diagnostics provided
• Density and API outputs provided
• Scraper („pig“) detection provided
Siemens FI 01 · 2016
3/361
3
© Siemens AG 2016
Flow Measurement
SITRANS F US Clamp-on
SITRANS FUH1010 (Oil)
■ Technical specifications
3
Specifications for interface detectors
Accuracy
Accuracy
Zero Drift
0.0003 m/s (0.001 ft/s), with
ZeroMatic Path active
(not provided for interface detector)
Data refresh rate
5 Hz
Accuracy
 0.05 of API No.
Repeatability
 0.01 of API No.
Specifications for volumetric and mass flowmeters
Rated operation conditions
Input
Degree of protection
Flow range
 12 m/s ( 40 ft/s), bidirectional
• Wall mount
IP65 (NEMA 4X)
Flow sensitivity
0.0003 m/s (0.001 ft/s), flow rate
independent
• Wall mount explosionproof
IP66 (NEMA 7)
Accuracy
Typical accuracy
 0.5 to 1 % of flow
Calibratable accuracy
 0.15 % … 0.3 % of flow,
depending on version
Batch repeatability
 0.05 % of flow, maximum
Specifications for all SITRANS FUH1010 products
Input
Pipe size
6.4 mm ... 9.14 m (0.25“ ... 360“)
Analog inputs
• Current: 4 x 4 ... 20 mA (IP65
(NEMA 7) enclosure has (2))
Output
• Standard
-40 ... +120 °C (-40 ... +250 °F)
• Optional
-40 ... +230 °C (-40 ... +450 °F)
Ambient temperature
-18 ... +60 °C (0 ... 140 °F)
Design
Dimensions
see SITRANS F US Clamp-on
"System info and selection guide"
Weight
see diagrams
Power supply
• IP65 (NEMA 4X) wall mount and
IP66 (NEMA 7) wall mount explosionproof
90 ... 240 V AC, 50 … 60 Hz,
30 VA or 9 ... 36 V DC, 12 W
Indication and operation
Standard outputs
Extended outputs
Status/Alarm I/O
3/362
Liquid temperature
Siemens FI 01 · 2016
• Current: 20 mA
(1 k at 30 VDC)
• Voltage: 10 V DC
(5 k minimum) (None for IP65
(NEMA 7) enclosure)
• Pulse Rate: 5 kHz, Digital Quad.
(None for IP65 (NEMA7))
• VT100 RS 232
• HART, BACnet MSTP/BACnet IP,
Modbus RTU & TCP/IP,
Ethernet IP, Johnson N2
• 4 x 4 ... 20 mA (not for IP65
(NEMA 7)
enclosure)
• Form C relays (not for IP65
(NEMA 7) enclosure)
• Digital pulse (not for IP65
(NEMA 7) enclosure)
• Programmable relays
(not for IP65 (NEMA 7) enclosure)
• Optically coupled output
logic gates (for IP65 (NEMA 7)
enclosure, only)
• Totalizer clear switch input
(not for IP65 (NEMA 4X) enclosure)1)
• Totalizer hold switch input
(not for IP65 (NEMA 7) enclosure)1)
• Opto iso. totalizer clear switch
input (for IP65 (NEMA 7) enclosure, only)1)
• Opto iso. totalizer hold switch input (for IP65 (NEMA 7) enclosure, only)1)
Data logger memory
1 MByte
Display
• IP65 (NEMA 4X) and
IP66 (NEMA 7) Enclosures
128 x 240 pixel LCD with backlight
• IP65 (NEMA 7) Enclosure
2 x 16 Alphanumeric LCD Display
Keypad
• IP65 (NEMA 4X) and
IP66 (NEMA 7) Enclosures
33 keypad buttons with tactile
feedback
• IP65 (NEMA 7) Enclosure
5 Magnetic hall effect switches
Language options
English, Spanish, German, Italian,
French
1)
Totalizer switch inputs are not provided for the interface detector.
© Siemens AG 2016
Flow Measurement
SITRANS F US Clamp-on
SITRANS FUH1010 (Oil)
Certificates and approvals
IP65 (NEMA 4X) wall mount enclosure
FM and CSA
• Transmitter
N-I Class I, Div 2
S Class II, Div 2
Sensor
• I.S. Class I, II, Div 1
CE
EMC Directive 2014/30/EU
ATEX Directive 2014/34/EU
3
C-TICK
ATEX
• Transmitter:
Ex II (1) G [Ex ia] IIC
EX II 3 (1) G Ex nC [ia] IIC T5
• Sensors:
Ex II 1 G Ex ia IIC T5
IP66 (NEMA 7) wall mount explosionproof enclosure ratings
FM and CSA
• Transmitter
XP Class I, Div 1
D-I Class II, Div 1
N-I Class I, Div 2
S Class II, Div 2
Sensor
• I.S. Class I, II, Div 1
CE
EMC Directive 2014/30/EU
ATEX Directive 2014/34/EU
ATEX
• Transmitter:
Ex II (1) G [Ex ia] IIC
Ex II 3 (1) G Ex nC [ia] IIC T5
Ex II 2 (1) G Ex d [ia IIC] IIB + H2
T5
• Sensors:
Ex II 1 G Ex ia IIC T5
Siemens FI 01 · 2016
3/363
© Siemens AG 2016
Flow Measurement
SITRANS F US Clamp-on
SITRANS FUH1010 (Oil)
Standard MLFB for quick delivery on SITRANS FUH1010 (Oil)
Selection and Ordering data
Article No.
Order code
SITRANS FUH1010 (Oil)
7 M E 3 6 0 7 - 7 77 7 0 - 7 7 7 7
77 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Design
0
IP65 (NEMA 4X) wall mount
Number of ultrasonic paths/meter type
Dual path Standard Volume
3
4
Flowmeter functions and I/O configurations
includes graphic or digital display, IP66 (BNB6665 (NEMA 4X)) and
IP66 (NEMA 7) wall mount explosionproof units:
• Standard I/O
- Graphic display
- 2 x 0 ... 10 V
- 2 x 4 ... 20 mA (active)
- 2 x 0 ... 5 kHz pulse outputs (TTL)
- 4 x form C relays
- 4 x logic inputs (totalizer control, TTL)
- 4 x 4 ... 20 mA analog input
- 1 x Pt100 RTD input per channel
A
Meter power options
A
90 ... 240 V AC
Communication options
0
VT100 RS 232
RTD temperature sensor
(includes mounting hardware for pipes above 1.5“/38 mm OD)
No RTDs
1 x standard clamp-on RTD
2 x standard clamp-on RTD
1 x submersible clamp-on RTD
2 x submersible clamp-on
RTD
Notes:
1. Temperature input is required for SITRANS FUH1010 systems
2. Only the Interface detector set up as a dual channel can use 2 RTD’s
0
1
2
3
4
Sensor for channel 1
(includes pipe mounting kit and spacer bar for indicated max. outer diam. listed)
no sensor
C2H (high precision)1)
D1H (high precision)1)
D4H (high
precision)1)
D1H (high
precision)1)
Mounting frame and straps provided up to
600 mm (24")
Mounting frame and straps provided up to
1200 mm (48")
Mounting frame and straps provided up to
1200 mm (48")
High Temperature to 104 °C/220 °F
A
N
P
R
Z
P1P
Sensor for channel 2
(includes pipe mounting kit and spacer bar for indicated max. OD listed)
See "Sensor selection charts" for specifications.
no sensor
C2H (high precision)1)
D1H (high precision)1)
D4H (high precision)1)
D1H (high precision)1)
Mounting frame and straps provided up to
600 mm (24")
Mounting frame and straps provided up to
1200 mm (48")
Mounting frame and straps provided up to
1200 mm (48")
High Temperature to 104 °C/220 °F
A
N
P
R
Z
Q1 P
Approvals
FM/CSA/CE (default)
ATEX, CE, C-TICK
Standard MLFB product offering represents 4 to 6 weeks delivery time
1)
Made with stainless steel constuction.
For sensor and RTD cables for quick delivery see tables at end of section.
3/364
Siemens FI 01 · 2016
1
2
K12 + K1 2 + R12
© Siemens AG 2016
Flow Measurement
SITRANS F US Clamp-on
SITRANS FUH1010 (Oil)
Selection and Ordering data
Article No.
Ord. code
SITRANS FUH1010 (Oil)
Article No.
Selection and Ordering data
• IP65 (NEMA 4X) wall mount
7ME3600-
• IP65 (NEMA 4X) wall mount
7ME3600-
• IP66 (NEMA 7) wall mount explosionproof
7ME3603-
• IP66 (NEMA 7) wall mount explosionproof
7ME3603-
7 777 0 - 7 7 7 7 7 7 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
0
1
2
3
4
9
H1A
Flowmeter functions and I/O configurations
Includes graphic or digital display
IP65 (NEMA 4X) wall mount and IP66
(NEMA 7 wall mount explosionsproof) units
A
• Extended I/O
- Graphic display
- 2 x 0 ... 10 V
- 2 x 4 ... 20 mA (active)
- 2 x 4 ... 20 mA (passive)
- 2 x 0 ... 5 kHz pulse outputs (TTL or OC)
- 4 x form C relays
- 4 x logic inputs (totalizer control, TTL)
- 4 x 4 ... 20 mA analog input
- 1 x Pt100 RTD input per channel
(Dual channel/path)
- 1 x Pt100 RTD input (Multi channel/path)
C
Meter power options
A
B
Communication options
VT100 RS 232
HART, BACnet MSTP/BACnet IP, Modbus RTU
& TCP/IP, Ethernet IP, Johnson N2,
VT100 RS 232
No RTDs (Note: temperature input is required
for SITRANS FUH systems)
1 x Standard clamp-on RTD
2 x Standard clamp-on RTD2)
1 x Submersible clamp-on RTD
2 x Submersible clamp-on RTD2)
0
2
0
3
1
2
3
4
Sensor for channel/path 1
(includes standard pipe mounting kit and
spacer bar for indicated max. outer diameter
listed)
See "Sensor selection charts" for specifications.
A
no sensor
• Standard I/O
- Graphic display
- 2 x 0 ... 10 V
- 2 x 4 ... 20 mA (active)
- 2 x 0 ... 5 kHz pulse outputs (TTL)
- 4 x form C relays
- 4 x logic inputs (totalizer control, TTL)
- 4 x 4 ... 20 mA analog input
- 1 x Pt100 RTD input per channel
(Dual channel/path)
- 1 x Pt100 RTD input (Multi channel/path)
90 ... 240 V AC
9 ... 36 V DC
7 777 0 - 7 7 7 7 7 7 7
RTD temperature sensor
(includes mounting hardware for pipes above
1.5“ OD)
Number of ultrasonic paths/meter type
Single path (precision volume)
Single path (interface detector)
Dual channel/Dual path (interface detector)
Dual path (precision volume)
Dual path (standard volume/mass)
Special: Four path (standard volume/mass)
only
Ord. code
SITRANS FUH1010 (Oil)
For the following High Precision sensors,
temperature range is -40 °C to +120 °C
(-40 °F to +248 °F), nominal 21 °C (70 °F):
A2H (high precision) Trackmount and straps
provided up to
75 mm (3”)
A3H (high precision) Trackmount and straps
provided up to
75 mm (3”)
B1H (high precision) Trackmount and straps
provided up to
125 mm (5”)
B2H (high precision) Trackmount and straps
provided up to
125 mm (5”)
B3H (high precision) Trackmount and straps
provided up to
125 mm (5”)
C1H (high preciMounting frame and
sion)3)
straps provided up to
600 mm (24”)1)
C2H (high preciMounting frame and
sion)3)
straps provided up to
600 mm (24”)1)
D1H (high preciMounting frame and
sion)3)
straps provided up to
1200 mm (48”)1)
D2H (high preciMounting frame and
sion)3)
straps provided up to
1200 mm (48”)1)
D3H (high preciMounting frame and
sion)3)
straps provided up to
1200 mm (48”)1)
D4H (high preciMounting frame and
sion)3)
straps provided up to
1200 mm (48”)1)
Siemens FI 01 · 2016
H
J
K
L
T
M
N
P
Q
U
R
3/365
© Siemens AG 2016
Flow Measurement
SITRANS F US Clamp-on
SITRANS FUH1010 (Oil)
Selection and Ordering data
Article No.
Ord. code
SITRANS FUH1010 (Oil)
Selection and Ordering data
• IP65 (NEMA 4X) wall mount
7ME3600-
• IP65 (NEMA 4X) wall mount
7ME3600-
• IP66 (NEMA 7) wall mount explosionproof
7ME3603-
• IP66 (NEMA 7) wall mount explosionproof
7ME3603-
7 777 0 - 7 7 7 7 7 7 7
Sensor for channel/path 1 (continued)
3
Article No.
For the following High Precision sensors,
temperature range is -40 °C to +120 °C
(-40 °F to +248 °F), nominal 65 °C (150 °F):
B1H (high temperature range HP)
B2H (high temperature range HP)
B3H (high temperature range HP)
C1H (high temperature range HP)3)
C2H (high temperature range HP)3)
D1H (high temperature range HP)1)3)
D2H (high temperature range HP)1)3)
D3H (high temperature range HP)1)3)
D4H (high temperature range HP)1)3)
Z
Z
Z
Z
Z
Z
Z
Z
Z
P1K
P1L
P1T
P 1M
P1N
P1P
P1Q
P1U
P1R
Siemens FI 01 · 2016
Z
Z
Z
Z
Z
Z
Z
Z
Z
Q1K
Q1L
Q1T
Q1M
Q1N
Q1P
Q1Q
Q1U
Q1R
Approvals
1
2
1)
Supplied spacer bar supports pipes up to 750 mm (30 inch). For pipes
larger than 750 mm (30 inch) purchase also, spare part
7ME3960-0MS40 (1012BN-4).
2)
Dual channel interface detector only
3)
Made with stainless steel construction.
A
For the following High Precision sensors,
temperature range is -40 °C to +120 °C
(-40 °F to +248 °F), nominal 21 °C (70 °F):
A2H (high precision) Trackmount and straps
provided up to
75 mm (3”)
A3H (high precision) Trackmount and straps
provided up to
75 mm (3”)
B1H (high precision) Trackmount and straps
provided up to
125 mm (5”)
B2H (high precision) Trackmount and straps
provided up to
125 mm (5”)
B3H (high precision) Trackmount and straps
provided up to
125 mm (5”)
C1H (high preciMounting frame and
3)
sion)
straps provided up to
600 mm (24”)1)
C2H (high preciMounting frame and
sion)3)
straps provided up to
600 mm (24”)1)
D1H (high preciMounting frame and
sion)3)
straps provided up to
1200 mm (48”)1)
D2H (high preciMounting frame and
sion)3)
straps provided up to
1200 mm (48”)1)
D3H (high preciMounting frame and
sion)3)
straps provided up to
1200 mm (48”)1)
D4H (high preciMounting frame and
sion)3)
straps provided up to
1200 mm (48”)1)
3/366
7 777 0 - 7 7 7 7 7 7 7
For the following High Precision sensors,
temperature range is -40 °C to +120 °C
(-40 °F to +248 °F), nominal 65 °C (150 °F):
B1H (high temperature range HP)
B2H (high temperature range HP)
B3H (high temperature range HP)
C1H (high temperature range HP)3)
C2H (high temperature range HP)3)
D1H (high temperature range HP)1)3)
D2H (high temperature range HP)1)3)
D3H (high temperature range HP)1)3)
D4H (high temperature range HP)1)3)
FM/CSA/CE/C-TICK (default), also for non
hazardous area
ATEX
Sensor for channel/path 2
(includes pipe mounting kit and spacer bar
for indicated max. outer diameter listed)
See "Sensor selection charts" for specifications.
no sensor
Ord. code
SITRANS FUH1010 (Oil)
H
Selection and Ordering data
J
Order code
Further designs
Please add "-Z" to Article No. and specify Order code(s).
K
Cable assembly for sensors (add for # of paths)
See "Sensor cable selection chart"
K..
L
Cable assembly for RTDs (add for # of RTDs)
See "RTD cable selection chart"
R..
Cable termination kit (for one cable pair)
T
M
N
P
Q
U
R
• Termination for standard, plenum and armored sensor
cable
• Termination for submersible cable
T01
• RTD cable termination kit for standard RTD
T21
• RTD cable termination kit for submersible RTD
T31
• Cable gland kit
T51
T11
Languages (Meter and Documentation), English
(default)
• German
• French
• Spanish
• Italian
B10
B12
B13
B14
Tag name plate
• Stainless steel tags with 3.2 mm (0.13 inch) characters
(68 characters max.)
Y19
© Siemens AG 2016
Flow Measurement
SITRANS F US Clamp-on
SITRANS FUH1010 (Oil)
High precision sensor selection chart IP68
Article No.
Selection and Ordering data
Based on pipe wall thickness (steel pipes only)
Operating Instructions for
SITRANS FUH1010
English NEMA 4X & NEMA 7 wall mount
Standard Volume
German NEMA 4X & NEMA 7 wall mount
Standard Volume
Sensor
A5E02951449
A5E02951529
English NEMA 4X & NEMA 7
wall mount explosionproof
Precision Volume
English NEMA 4X & NEMA 7
wall mount explosionproof
Interface Detector
CQO:1010PVNFM-3
A5E02951504
This device is shipped with a Quick Start Guide and a CD containing
further SITRANS F literature.
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
■ MLFB example
Application example
A clamp-on meter is required for a 12“ carbon steel hydrocarbon
line flowing multiple products, with a wall thickness of 12.7 mm
(0.5“). Meter electronics are to be located in a Class I Div 2 area
only 60 ft from the pipeline. 12 V DC power is available at the
site.
Dual path operation is desired for improved accuracy and redundant measurement. Pulse output will be primary flow data
source.
SITRANS FUH1010 meter
family
IP65 (NEMA 4X) enclosure
Dual path precision volume
Custody Transfer option with
digital pulse
9 ... 36 V DC power option
VT100 RS 232
RTD required for viscosity comp
Sensor code for path 1
Sensor code for path 2
FM approval required
Pipe wall (mm)
Pipe wall (inch)
min.
max.
min.
max.
A1H
G
0.64
1.02
0.025
0.04
A2H
H
1.02
1.52
0.04
0.06
A3H
J
1.52
2.03
0.06
0.08
B1H
K
2.03
3.05
0.08
0.12
B2H
L
3.05
4.06
0.12
0.16
C1H1)
M
4.06
5.84
0.16
0.23
C2H1)
N
5.84
8.13
0.23
0.32
D1H1)
P
8.13
11.18
0.32
0.44
D2H1)
Q
11.18
15.75
0.44
0.62
D4H1)
R
15.75
31.75
0.62
1.25
B3H1)
T
2.7
3.3
0.106
0.128
D3H1)
U
7.4
9.0
0.293
0.354
1)
Made with stainless steel construction.
Sensor Cable Selection Chart
Sensor cable codes for length and type options
Cable length m Standard (PVC
(ft)
jacket)
Submersible
(polyethylene
jacket)
-40…+80 °C
Plenum Rated
(teflon jacket)
Armored
-40…+80 °C
-40…+200 °C
-40…+80 °C
(-40…+176 °F) (-40…+176 °F) (-40…+392 °F) (-40…+176 °F)
Order code
MLFB Article No.: 7ME3600-3CB00-3QQ1-Z
K03 + K03 + R03
Selection and Ordering data
Order
Code
Pipe wall
Article No.
Ord. code
7 M E 3 6 0 7 - 7 777 0 - 7 7 7 7 7 7 7
0
3
6 (20)
K011)
K11
K21
K31
15 (50)
K02
K121)
K22
K321)
30 (100)
K031)
K131)
K23
K33
46 (150)
K041)
K14
K24
K34
61 (200)
K05
K15
K25
K35
91 (300)
K06
K16
K26
K36
1)
C
Standard MLFB for quick delivery
RTD Cable Selection Chart
RTD cable codes for length and type
B
Cable length m (ft)
0
3
Q
Standard
(teflon wrapped)
-40 ... +200 °C
(-40 … +392 °F)
Submersible (extruded
jacket)
-40 ... +200 °C
(-40 … +392 °F)
Order code
Q
1
30 m (100 ft) sensor cable for path 1
K0 3
30 m (100 ft) sensor cable for path 2
K0 3
30 m (100 ft) cable for RTD
R0 3
6 (20)
R011)
R11
15 (50)
R021)
R12
30 (100)
R031)
R13
46 (150)
R04
R14
61 (200)
R05
R15
91 (300)
R06
R16
1)
Standard MLFB for quick delivery
Siemens FI 01 · 2016
3/367
3