SITRANS FST020 ultrasonic clamp-on flow meter catalog sheet

© Siemens AG 2016
Flow Measurement
SITRANS F US Clamp-on
SITRANS FST020 (Basic)
■ Overview
■ Function
• 2 x16 integral alphanumeric display and 5 key keypad for installation menu and data display
• Pulse rate output
• Communications include VT100 RS 232 with a DB9 connector,
Modbus RTU, BACnet MSTP
• Totalizer start/stop and rest control lines.
• Remote PC installation menu
• ZeroMatic Path automatically sets zero
• Bidirectional flow operation
• 1 MByte data logger with both site & data logger storage
• Menu language in English, Spanish, German, Italian and
French
■ Technical specifications
Input
SITRANS FST020 offers reliable flow measurement at a much
lower cost than other clamp-on ultrasonic flowmeters, with flow
rate accuracy of ± 0.5 % to 1.0 % for most applications.
■ Benefits
• Easy installation; no need to cut pipe or stop flow
• Minimal maintenance; external sensors do not require periodic cleaning
• No moving parts to wear or foul
• No pressure drop or energy loss
• Compact, integral design reduces installation cost
• Wide turn-down ratio
• Optional WideBeam technology ensures high performance.
• ZeroMatic Path automatically sets zero without stopping flow
and eliminates zero drift.
■ Application
SITRANS FST020 is suitable for most clean liquid applications,
including the following:
• Water & wastewater industry
- Potable water
- Wastewater, influent & effluent
- Processed sewage, sludge
• Chemical feed industry
- Sodium hypochlorite
- Sodium hydroxide
• HVAC & power industries
- Coolant flow
- Fuel flow
• Process control
- Chemicals
- Pharmaceuticals
The SITRANS FST020 flowmeter is not available with hazardous
areas
approval.
■ Design
• IP65 (NEMA 4X) wall mount constructed of polycarbonate
• Single channel versions only
Flow range
 12 m/s ( 40 ft/s), bi-directional
Flow sensitivity
0.0003 m/s (0.001 ft/s) flow rate
independent
Digital Inputs
Totalizer Hold
Optically isolated diode
Input voltage: 2 … 10 V DC
Totalizer Reset
Optically isolated diode
Input voltage: 2 … 10 V DC
Output
Current
• 4 ... 20 mA (Isolated)
• externally powered
10 … 30 V DC
Relay
• Programmable Form C 250 mA
• 30 V DC
• 3 V A max
Pulse rate1)
• Optically isolated transistor
10 mA
• 30 V DC max
Accuracy
For velocities  0.3 m/s (1 ft/s)
• 4 ... 20 mA
± 1.0 % of flow
• Pulse, relay output
± 0.5 % ... 1.0 % of flow
Batch repeatability
 0.15 %
Zero Drift
0.1 % of rate;
0.0003 m/s (0.001 ft/s)
Data refresh rate
5 Hz
Transmitter conditions
Operating temperature
-10 … +50 °C (14 … +122 °F)
Storage temperature
-20 … +60 °C (-4 … +140 °F)
Degree of protection
IP65 NEMA 4X
Design
Weight
1.4 kg (3.0 lb)
Dimensions (W x H x D)
175 x 235 x 92 mm
(6.89 x 9.25 x 3.62 inch)
Enclosure material
Polycarbonate
Power supply
100 ... 240 V AC @ 20 VA or
11.5 ... 28.5 V DC @ 10 W
Certificates and approvals
Unclassified locations
UL, ULc
Classified locations
CE
EMC Directive 2014/30/EU
ATEX Directive 2014/34/EU
C-TICK
1)
When used to represent flow rate (PGEN) the frequency can reach as
high as 5000 Hz. When used to represent flow total it can reach
50 Hz.
Siemens FI 01 · 2016
3/339
3
© Siemens AG 2016
Flow Measurement
SITRANS F US Clamp-on
SITRANS FST020 (Basic)
Standard MLFB for quick delivery on SITRANS FST020 (Basic)
Selection and Ordering data
Article No.
SITRANS FST020 (Basic)
7 M E 3 5 7 7 - 7 77 3 0 - 0 7 7 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Design
0
IP65 (NEMA 4X ) wall mount
Number of channels/ultrasonic paths
Single channel
3
1
Flowmeter functions and I/O configurations
• With display and 1 additional analog output and SPST relay
H
Meter power options
100 ... 240 V AC
A
11.5 ... 28.5 V DC, 10 W max
B
Sensor
(includes pipe mounting kit for indicated max. OD listed)
See "Sensor selection charts" for specifications.
A
no sensor
A2 universal
Trackmount and straps provided up to 75 mm (3")
B
B3 universal
Trackmount and straps provided up to 125 mm (5")
C
C3 universal2)
Mounting frame and straps provided up to 300 mm (13")
D
D3 universal2)
Mounting frame and straps provided up to 600 mm (24")
E
E2 universal2)
Mounting frame and straps provided up to 1200 mm (48")1)
F
For the following High Precision sensors, temperature range is -40 ... +120 °C (-41 ... +150 °F), nominal 21 °C (70 °F)
C1H (high precision)2)
Mounting frame and straps provided up to 600 mm (24")
M
C2H (high precision)2)
Mounting frame and straps provided up to 600 mm (24")
N
D1H (high precision)2)
Mounting frame and straps provided up to 1200 mm (48")1)
P
D4H (high precision)2)
Mounting frame and straps provided up to 1200 mm (48")1)
R
Sensor cables
No sensor cable
A
6 m (20 ft) PVC Jacket (1 pr)
B
15 m (50 ft) PVC Jacket (1 pr)
C
30 m (100 ft) PVC Jacket
D
46 m (150 ft) PVC Jacket
E
91 m (300 ft) PVC Jacket
G
Approvals
UL, ULC, CE, C-TICK
0
Standard MLFB offering represents 2 to 3 weeks delivery time for quantities under 5.
1)
Supplied spacer bar suppports pipes up to 750 mm (30 inch). For pipes larger than 750 nn (30 inch) purchase also, spare part 7ME3960-0MS40 (1012BN-4).
2)
Made of stainless steel construction.
3/340
Siemens FI 01 · 2016
© Siemens AG 2016
Flow Measurement
SITRANS F US Clamp-on
SITRANS FST020 (Basic)
Selection and Ordering data
SITRANS FST020 (Basic) IP65 (NEMA 4x)
Article No.
Ord. code
7ME3570-
Article No.
Selection and Ordering data
SITRANS FST020 (Basic) IP65 (NEMA 4x)
7 77 3 0 - 0 7 7 7 7 7 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Single channel
1
Flowmeter functions and I/O configurations
• With display, keypad, 1x 4 ... 20 mA, 1x relay,
1x pulse/frequency, 2x digital input, VT100
RS232, Modbus RTU, BACnet MSTP
H
Sensor for channel 11)
Including pipe mounting tracks for Sizes A &
B universal sensors indented for pipe with a
OD less than 125 mm (5") and mounting
frame/spacer bars for sizes C, D & E universal
sensors. Straps provided are for the indicated
maximum OD listed below. Strap kits are
available to accommodate larger pipes (refer
to spare part list). Refer to "Sensor Selection
Charts" for the sensor suitability of pipe size
and wall thickness
no sensor
A2 universal
Trackmount and straps
provided up to
75 mm (3”)
B3 universal
Trackmount and straps
provided up to
125 mm (5”)
2)
C3 universal
Mounting frame and
straps provided up to
330 mm (13”)
2)
D3 universal
Mounting frame and
straps provided up to
600 mm (24”)
E2 universal2)
Mounting frame and
straps provided up to
1200 mm (48”)
For the following High Precision sensors,
temperature range is -40 ... +120 °C
(-40 ... +248 °F), nominal 21 °C (70 °F)
A2H (high precision) Trackmount and straps
provided up to
75 mm (3")
A3H (high precision) Trackmount and straps
provided up to
75 mm (5")
B1H (high precision) Trackmount and straps
provided up to
125 mm (5")
B2H (high precision) Trackmount and straps
provided up to
125 mm (5")
C1H (high preciup to 600 min (24") with
sion)2)
mounting hardware
C2H (high preciup to 600 min (24") with
2)
sion)
mounting hardware
D1H (high preciMounting frame and
2)
sion)
straps provided up to
1200 mm (48")1)
D2H (high preciMounting frame and
sion)2)
straps provided up to
1200 mm (48")1)
D4H (high preciMounting frame and
sion)2)
straps provided up to
1200 mm (48")1)
Z
P1A
Z
P1B
Z
P1C
3
Sensor cables (pair)
Meter power options
100 ... 240 V AC
11.5 ... 28.5 V DC
7 77 3 0 - 0 7 7 7 7 7 7
High temperature sensor size 2 for up to
230 °C (446 °F) (30 to 200 mm diam.
(1 to 8 inch diam.))
High temperature sensor size 3 for up to
230 °C (446 °F) (150 to 610 mm diam.
6 to 24 inch diam.))
High temperature sensor size 4 for up to
230 °C (446 °F) (400 to 1200 mm
diam. (16 to 48 inch diam.))
Number of channels/ultrasonic paths
Ord. code
7ME3570-
A
B
A
B
C
D
No sensor cable
6 m (20 ft) PVC Jacket
15 m (50 ft) PVC Jacket
30 m (100 ft) PVC Jacket
A
B
C
D
46 m (150 ft) PVC Jacket
61 m (200 ft) PVC Jacket
91 m (300 ft) PVC Jacket
E
F
G
6 m (20 ft) Plenum rated (Teflon jacket)
15 m (50 ft) Plenum rated (Teflon jacket)
30 m (100 ft) Plenum rated (Teflon jacket)
H
J
K
46 m (150 ft) Plenum rated (Teflon jacket)
61 m (200 ft) Plenum rated (Teflon jacket)
91 m (300 ft) Plenum rated (Teflon jacket)
L
M
N
Approvals
0
UL, ULC, CE, C-TiCK
1)
Supplied spacer bar supports pipes up to 1050 mm (42"). For pipes larger
than 1050 mm (42") purchase also, spare part 7ME3960-0MS40 (1012BN-4)
2)
Made of stainless steel construction.
E
F
H
J
K
L
M
N
P
Q
R
Siemens FI 01 · 2016
3/341
© Siemens AG 2016
Flow Measurement
SITRANS F US Clamp-on
SITRANS FST020 (Basic)
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Article No. and specify Order code(s).
Cable termination kit (for one cable pair)
• Sensor cable termination for standard and plenum
cable
T01
Wet flow transfer calibration (priced on request)
6 point calibration 2/water (Price per channel)
3
• 2SS40 pipe
• 3CS40 pipe
• 4CS40 pipe
• 4SS40 pipe
D01
D02
D03
D04
• 6CS40 pipe
• 6SS40 pipe
• 6CS120 pipe
• 8CS40 pipe
D05
D06
D07
D08
• 8SS40 pipe
• 8CS120 pipe
• 10CS Standard pipe
• 10CS40 pipe
D09
D10
D11
D12
• 10SS40 pipe
• 12CS Standard pipe
• 12CS40 pipe
• 14CS30 pipe
D13
D14
D15
D16
• 14CS40 pipe
• 16CS Standard pipe
• 16CS40 pipe
• 18CS Standard pipe
D17
D18
D19
D20
• 20CS20 pipe
• 20CS30 pipe
• 24CS Standard pipe
• 24CS20 pipe
D21
D22
D23
D24
• 24CS30 pipe
• 30CS Standard pipe
• 36CS Standard pipe
• Other pipe, other liquid, additional points, witness
D25
D26
D27
Y28
Tag name plate
• Stainless steel tags with 3.2 mm (0.13 inch) character
size (68 characters max.)
Y19
■ MLFB example
Selection and Ordering data
Order code
Operating Instructions for
SITRANS FST020
English NEMA 4X
German NEMA 4X
A5E03086487
A5E03086488
This device is shipped with a Quick Start Guide and a CD containing
further SITRANS F literature.
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
Universal sensor selection chart IP68
Based on pipe size (pipes other than steel)
Pipe size
Order
Code
Outer diameter
range (mm)
Outer diameter
range (inch)
A2
B
min.
max.
min.
max.
12.7
50.8
0.5
2
B3
C31)
C
19
127
0.75
5
D
51
305
2
12
D31)
E
203
610
8
24
E21)
F
254
6096
10
249
High precision sensor selection chart IP68
Based on pipe wall thickness (steel pipes only)
Pipe Wall
Order
Code
Pipe Wall [mm]
Pipe Wall [inch]
min.
max.
min.
max.
A1H
G
0.64
1.02
0.025
0.04
A2H
H
1.02
1.52
0.04
0.06
A3H
J
1.52
2.03
0.06
0.08
B1H
K
2.03
3.05
0.08
0.12
B2H
L
3.05
4.06
0.12
0.16
C1H1)
M
4.06
5.84
0.16
0.23
C2H1)
N
5.84
8.13
0.23
0.32
1)
D1H
P
8.13
11.18
0.32
0.44
D2H1)
Q
11.18
15.75
0.44
0.62
D4H1)
R
15.75
31.75
0.62
1.25
1)
Application example
A basic clamp-on meter is required for a DN 150 (6“ schedule
40) carbon steel waste water line, with a pipe wall thickness of
7.1 mm (0.28“). Meter electronics are to be located in an instrumentation shed with available AC power. 36 m (120 ft) of sensor
cable is needed to reach pipe location.
MLFB Article No.: 7ME3570-1HA30-0NE0
Selection and Ordering data
SITRANS FST020 meter family
IP65 (NEMA 4X) enclosure
Single channel
Standard I/O option
100 ... 240 V AC power option
Sensor code for channel 1
46 m (150 ft) sensor cable
3/342
Siemens FI 01 · 2016
Article No.
Ord. code
7 M E 3 5 7 7 - 7 77 3 0 - 0 7 7 0 7 7 7
0
1
H
A
N
E
Made of stainless steel construction.