Proximity Sensor with All-stainless Housing E2EF Metal Head for long-distance Detection that Withstands Harsh Environments Where the Workpiece Can Rub against the Sensor • Completely stainless-steel housing • Long-distance detection equivalent to or greater than Proximity Sensors with Resin Heads *1 • More than 20 times *2 the durability of Proximity Sensors with Resin Heads • Spatter-resistant Models with fluororesin coating are available. • Aluminum chip immunity • Pre-wired Smartclick Connector Models are also available. *1. The actual sensing distance will vary with the size or material of the object. For details, refer to Engineering Data. *2. Test results for stainless-steel brush rotating at 130 rpm. Be sure to read Safety Precautions on page 4. Note: Models with a fluororesin coating also use vinyl chloride for the cable material and require separate protection. Ordering Information Sensors [Refer to Dimensions on page 5.] Standard Models (Completely stainless-steel housing) Connection method Appearance Shielded Sensing distance M8 M12 Pre-wired Models (2m) 2mm Pre-wired Smartclick Connector Models (M12) M12 E2EF-X7D1 2M 7mm 12mm DC 2-Wire (polarity) 2mm NO E2EF-X2D1-M1TGJ 0.3M E2EF-X7D1-M1TGJ 0.3M 7mm M30 E2EF-X12D1 2M E2EF-X3D1-M1TGJ 0.3M 3mm M18 Model E2EF-X3D1 2M 3mm M18 Shielded Operation mode E2EF-X2D1 2M M30 M8 Output E2EF-X12D1-M1TGJ 0.3M 12mm Spatter-resistant Models (Completely stainless-steel housing with fluororesin coating) Connection method Appearance Shielded Sensing distance M8 M12 Pre-wired Models (2m) Pre-wired Smartclick Connector Models (M12) M12 M18 Model E2EF-QX2D1 2M E2EF-QX3D1 2M 3mm E2EF-QX7D1 2M 7mm M30 Shielded Operation mode 2mm M18 M8 Output 12mm DC 2-Wire (polarity) 2mm E2EF-QX12D1 2M E2EF-QX2D1-M1TGJ 0.3M E2EF-QX3D1-M1TGJ 0.3M 3mm E2EF-QX7D1-M1TGJ 0.3M 7mm M30 NO E2EF-QX12D1-M1TGJ 0.3M 12mm Note: Vinyl chloride is used for the cable material, and separate protection is required. Accessories (Order Separately) Sensor I/O Connectors Smart Click Connectors Cable connection direction Cable specifications Straight Flame-retardant, flexible cable Cable length No. of cable conductors 2m 4 XS5F-D421-D80-F 5m 4 XS5F-D421-G80-F Model Applicable Proximity Sensor model number E2EF-X@D1-M1TGJ E2EF-QX@D1-M1TGJ 1 E2EF Ratings and Specifications Size Shielded M8 Completely stainlessExterior steel housing Item Model Sensing distance Set distance Differential travel Sensing object Standard sensing object Response frequency * Power supply voltage Leakage current Output configuration Switching capacity Control output Residual voltage Indicators Operation mode (with sensing object approaching) Protection circuits Ambient temperature range Ambient humidity range Temperature influence Voltage influence Insulation resistance Dielectric strength Vibration resistance Shock resistance Degree of protection Connection method Pre-wired Models (2 m) Pre-wired Connector Models Case Sensing surface (thickness) Materials Clamping nuts Toothed washer Cable Accessories Weight (packed state) E2EF-X2D1 (-M1TGJ) M12 Fluororesin coating E2EF-QX2D1 (-M1TGJ) Completely stainlesssteel housing E2EF-X3D1 (-M1TGJ) M18 Shielded Completely Fluororesin Fluororesin stainlesscoating coating steel housing E2EF-QX3D1 (-M1TGJ) E2EF-X7D1 (-M1TGJ) E2EF-QX7D1 (-M1TGJ) M30 Completely stainlesssteel housing E2EF-X12D1 (-M1TGJ) Fluororesin coating E2EFQX12D1 (-M1TGJ) 2mm±10% 3mm±10% 7mm±10% 12mm±10% 0 to 1.4 mm 0 to 2.1mm 0 to 4.9mm 0 to 8.4mm 15% max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 6.) Iron, 12 × 12 × 1 mm Iron, 12 × 12 × 1 mm Iron, 30 × 30 × 1 mm Iron, 54 × 54 × 1 mm 200Hz 80Hz 100Hz 50Hz 10 to 30 VDC, ripple (p-p) : 10% max. 0.8 mA max. With polarity 3 to 100 mA 3 V max.(Load current : 100 mA max., Cable length : 2 m) Operation indicator (red LED), Setting indicator (green LED) NO(normally open) Surge suppressor, Load short-circuit protection Operating : −10 to 70°C, Storage : −25 to 70°C (with no icing or condensation) Operating/Storage : 35% to 95% (with no condensation) ±20% max. of sensing distance at 23°C in the temperature range of −10 to 70°C. ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range 50 MΩ min. (at 500 VDC) between current-carrying parts and case 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case Destruction : 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Destruction : 500 m/s2 10 times each in X, Y, and Z di- Destruction : 1,000 m/s2 10 times each in X, Y, and Z directions rections IEC 60529 IP67 Unmarked : Pre-wired Models (Standard cable length : 2 m) Models ending with -M1TGJ : Pre-wired Connector Models (Standard cable length : 300 mm) Approx. 105 g Approx. 190 g Approx. 215 g Approx. 295 g Approx. 65 g Approx. 85 g Approx. 110 g Approx. 190 g 0.4mm 0.5mm Stainless steel (SUS303) (E2EF-QX@ : Fluororesin coating) Stainless steel (SUS303) (E2EF-QX@ : Fluororesin coating) 0.2mm 0.4mm Stainless steel (SUS303) (E2EF-QX@ : Fluororesin coating) Zinc-plated iron PVC (flame retardant) Instruction manual * The response frequency of the DC switching section is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. I/O Circuit Diagrams Operation mode Model Timing chart Non-sensing area Unstable sensing area Output circuit Set position Stable sensing area Proximity sensor Sensing object Brown Load 1 NO E2EF-(Q)X@D1 (-M1TGJ) (%) 100 Rated sensing distance 70(TYP) 0 ON Setting indicator OFF (green) ON Operation indicator OFF (red) Proximity sensor main circuit 10 to 30 VDC < -M1TGJ > Connector Pin Arrangement 1 2 Blue 4 4 3 0V Note: The load can be connected to either the +V or 0 V side. Note: Pins 2 and 3 are not used. ON Control output OFF 2 E2EF Engineering Data (Reference Value) E2EF-X2D1 -QX2D1 14 E2EF-(Q)X12D1 12 10 2.5 @d X E2EF-X3D1 -QX3D1 t=1mm Iron 2.0 Stainless steel (SUS304) 1.5 8 Distance X (mm) Distance X (mm) Influence of Sensing Object Size and Material E2EF-X@ -QX@ Distance X (mm) Sensing Area 3.5 @d X 3.0 t=1mm Iron 2.5 2.0 Stainless steel (SUS304) E2EF-(Q)X7D1 6 Brass 1.0 E2EF-(Q)X2D1 4 E2EF-(Q)X3D1 0.5 X 0.0 0 -20 -15 Brass 1.0 Copper Y 2 1.5 Aluminum -10 -5 0 5 10 15 20 Aluminum 0.5 0 5 10 15 20 0 Side length of sensing object: d (mm) Distance Y (mm) Copper 0.0 5 10 15 20 25 30 Side length of sensing object: d (mm) Leakage Current E2EF-X12D1 -QX12D1 @d 7 X Iron t=1mm 6 Stainless steel (SUS304) 5 E2EF-X@ D1 14 @d X 12 t=1mm Iron Stainless steel (SUS304) 10 8 Leakage current (mA) 8 Distance X (mm) Distance X (mm) E2EF-X7D1 -QX7D1 0.8 0.7 E2EF-(Q)X2D1 E2EF-(Q)X12D1 0.6 4 6 3 Brass Brass 2 Aluminum 1 4 Aluminum 0 10 20 30 40 50 60 Side length of sensing object: d (mm) E2EF-(Q)X7D1 E2EF-(Q)X3D1 Copper Copper 0 0.5 2 0 0.4 0 10 20 30 40 50 60 70 Side length of sensing object: d (mm) 0 5 10 15 20 25 30 Power supply voltage (V) Residual Output Voltage Residual output voltage (V) E2EF-X@D1 -QX@ D1 5 4 3 E2EF-(Q)X@D1 2 1 0 1 3 5 10 30 50 100 Load current (mA) 3 E2EF Safety Precautions (Unit: mm) WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Item Model E2EF-(Q)X2D1 Never use this product with an AC power supply. Otherwise, explosion may result. E2EF-(Q)X3D1 E2EF-(Q)X7D1 Precautions for Safe Use The following precautions must be observed to ensure safe operation. 1. Do not use the Sensor in an environment where inflammable or explosive gas is present. 2. Do not attempt to disassemble, repair, or modify any Sensors. 3. Power Supply Voltage Do not use a voltage that exceeds the rated operating voltage range. Applying a voltage that is higher than the operating voltage range may result in explosion or fire. 4. Incorrect Wiring Be sure that the power supply polarity and other wiring is correct. Incorrect wiring may cause explosion or fire. 5. Connection without a Load If the power supply is connected directly without a load, the internal elements may explode or burn. Be sure to insert a load when connecting the power supply. E2EF-(Q)X12D1 D m n Iron 0 8 0 8 30 10 50 10 8 50 Iron 0 12 0 12 40 Aluminum 16 70 16 12 70 Iron 0 18 0 28 60 Aluminum 16 80 16 28 80 Iron 0 30 0 48 100 Aluminum 24 120 24 48 120 Note: The influence from other non-magnetic surrounding metals is nearly the same as that from aluminum. Mutual Interference When installing two or more Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained. (Unit: mm) Model Item A B E2EF-(Q)X2D1 35 35 E2EF-(Q)X3D1 40 35 E2EF-(Q)X7D1 65 60 Do not use the Sensor under ambient conditions that exceed the ratings. 1. Do not use the Sensor in the following locations. (1) Outdoor locations directly subject to sunlight, rain, snow, or water droplets (2) Locations subject to atmospheres with chemical vapors, in particular solvents and acids (3) Locations subject to corrosive gas 2. The Sensor may malfunction if used near ultrasonic cleaning equipment, high-frequency equipment, transceivers, cellular phones, inverters, or other devices that generate a high-frequency electric field. Refer to the OMRON website (www.ia.omron.com/) for typical measures. 3. Laying the Sensor wiring in the same conduit or duct as highvoltage wires or power lines may result in incorrect operation and damage due to induction. Wire the Sensor using a separate conduit or independent conduit. 4. Cleaning Never use thinner or other solvents. Otherwise, the Sensor surface may be dissolved. E2EF-(Q)X12D1 110 100 A B Chips from Cutting Aluminum Normally, chips from cutting aluminum will not cause a detection signal to be output even if it adheres to or accumulates on the detection surface. In the following cases, however, a detection signal may be output. Remove the cutting chips in these cases. 1. If d ≥ 2 3 D at the center of the detection sur- d face where d is the cutting chip size and D is the detection surface size (Unit: mm) Model Cutting chip D Detection surface D Dimension E2EF-(Q)X2D1 6 E2EF-(Q)X3D1 10 E2EF-(Q)X7D1 16 E2EF-(Q)X12D1 28 Pressed down Cutting chips 2.If the cutting chips are pressed down When the Proximity Sensor is embedded in metal, make sure that the clearances given in the following table are maintained. The values depend on the type of nuts used for mounting. Be sure to use the supplied nuts (SUS303). d dia. n m D l d Aluminum Precautions for Correct Use ● Design Influence of Surrounding Metal l Embedding material l ● Mounting Do not tighten the nut with excessive force. A washer must be used with the nut. Do not use tightening force that exceeds the values in the following table. Model Torque E2EF-(Q)X2D1 9 N·m E2EF-(Q)X3D1 30 N·m E2EF-(Q)X7D1 70 N·m E2EF-(Q)X12D1 180 N·m 4 E2EF (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Sensors Pre-wired Models E2EF-X2D1 -QX2D1 E2EF-X3D1 -QX3D1 49 4-dia. vinyl-insulated round cable with 2 conductors (flame retardant), (Conductor cross section : 0.2 mm2, Insulator diameter : 1.4 mm) Standard length : 2 m 30 25 15 dia. 4 8 Operation indicator (red) Setting indicator (green) Two clamping nuts M8×1 13 Toothed washer 6-dia. vinyl-insulated round cable with 2 conductors (flame retardant), (Conductor cross section : 0.5 mm2, Insulator diameter : 1.75 mm) Standard length : 2 m 53 4 21 dia. M12×1 17 39 33 10 Two clamping nuts Toothed washer Operation indicator (red) Setting indicator (green) E2EF-X12D1 -QX12D1 E2EF-X7D1 -QX7D1 63.5 49 56 42 36 29 dia. 13 4 Operation indicator (red) Two clamping nuts Setting indicator (green) Toothed washer M18×1 24 6-dia. vinyl-insulated round cable with 2 conductors (flame retardant), (Conductor cross section : 0.5 mm2, Insulator diameter : 1.75 mm) Standard length : 2 m 6-dia. vinyl-insulated round cable with 2 conductors (flame retardant), (Conductor cross section : 0.5 mm2, Insulator diameter : 1.75 mm) Standard length : 2 m 43 5 42 dia. 13 Operation indicator (red) Setting indicator (green) 36 Two clamping nuts Toothed washer M30×1.5 Smartclick Connector Models E2EF-X2D1-M1TGJ -QX2D1-M1TGJ E2EF-X3D1-M1TGJ -QX3D1-M1TGJ 53 49 15 dia. 4 30 25 4-dia. vinyl-insulated round cable (flame retardant), Standard length : 300 mm 8 21 dia. Operation indicator (red) Setting indicator (green) M12×1 M8×1 13 39 Toothed washer 17 Two clamping nuts E2EF-X7D1-M1TGJ -QX7D1-M1TGJ 4 6-dia. vinyl-insulated round cable (flame retardant), Standard length : 300 mm 10 Operation indicator (red) M12×1 Setting indicator (green) M12×1 Toothed washer Two clamping nuts E2EF-X12D1-M1TGJ -QX12D1-M1TGJ 63.5 56 42 29 dia. 4 24 33 36 M18×1 Toothed washer OMRON Corporation 13 6-dia. vinyl-insulated round cable (flame retardant), Standard length : 300 mm Operation indicator (red) Setting indicator (green) M12×1 Two clamping nuts 49 43 42 dia. 5 M30×1.5 36 Industrial Automation Company Toothed washer 13 6-dia. vinyl-insulated round cable (flame retardant), Standard length : 300 mm Operation indicator (red) Setting indicator (green) M12×1 Two clamping nuts Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Sensor Business Unit Carl-Benz-Str. 4, D-71154 Nufringen, Germany Tel: (49) 7032-811-0/Fax: (49) 7032-811-199 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 © OMRON Corporation 2012 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_3_2_1115 Printed in Japan Cat. No. D114-E1-01 0912 (0912) (w)