Download

New Product
Transparent Object Detection Photoelectric Sensor
E3S-DB
Superb Detection of Many Types of
Transparent Objects
• Double slits inside Sensor prevent incorrect operation.
• P-opaquing function* improves detection of PET bottles and
transparent films.
• Smart Teaching for optimum settings in as little as 3 seconds.
• Maximum sensing distance of 3.5 m.
• IP69K protection recommended for food and beverage
industry. Third-party certification from Ecolab in Europe for
detergent resistance.
• Variable connector and cable directions, and 360° indicators
for greater usability.
* This function uses polarization to opaque transparent objects that exhibit
double refraction.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Refer to the Safety Precautions on
page 7.
Ordering Information
Sensors (Refer to Dimensions on page 8.)
Sensing
method
Appearance
Sensitivity
adjustment
Connection method
Red light
Sensing distance *2
NPN output
PNP output
E3S-DBN11 2M
E3S-DBP11 2M
E3S-DBN21
E3S-DBP21
E3S-DBN31 0.3M
E3S-DBP31 0.3M
E3S-DBN12 2M
E3S-DBP12 2M
E3S-DBN22
E3S-DBP22
E3S-DBN32 0.3M
E3S-DBP32 0.3M
Pre-wired (2 m)
E3S-DBN11T 2M
E3S-DBP11T 2M
Connector (M12)
E3S-DBN21T
E3S-DBP21T
E3S-DBN31T 0.3M
E3S-DBP31T 0.3M
Pre-wired (2 m)
E3S-DBN12T 2M
E3S-DBP12T 2M
Connector (M12)
E3S-DBN22T
E3S-DBP22T
E3S-DBN32T 0.3M
E3S-DBP32T 0.3M
Pre-wired (2 m)
Connector (M12)
Smart
Teaching
M12 Smartclick prewired connector (0.3 m)
*1
M12 Smartclick prewired connector (0.3 m)
Eleven-turn
adjuster
3.5 m
(with E39-R8)
Pre-wired (2 m)
Connector (M12)
Retroreflective
(with MSR
function)
Model
M12 Smartclick prewired connector (0.3 m)
M12 Smartclick prewired connector (0.3 m)
Narrow beam 0.5 m
(with E39-R21)
3.5 m
(with E39-R8)
Narrow beam 0.5 m
(with E39-R21)
*1. A Reflector is not included with the Sensor. Select a Reflector (sold separately) according to the application.
*2. There is no close-range dead zone between the Sensor and Reflector.
1
E3S-DB
Accessories (Sold Separately)
Sensor I/O Connectors (Connector on One End) (A Connector is required for a Sensor with a connector or pre-wired connector.)
Connectors are not provided with the Sensors. Be sure to order a Connector separately.
Cable
specifications
Size
Cable
length
Appearance
Straight
Model
2m
XS2F-D421-D80-F
5m
XS2F-D421-G80-F
2m
XS5F-D421-D80-F
5m
XS5F-D421-G80-F
*2
Fire-retardant robot
*1
M12 (4 pins) cable
Straight
*2
*1 Refer to your OMRON website for details on the XS2 and XS5.
*2 The connectors will not rotate after they are connected.
Reflectors (A Reflector is required for each Retro-reflective Sensor.) (Refer to Dimensions on page 10.)
Reflectors are not provided with the Sensors. Be sure to order a Reflector separately.
Appearance
Sensing distance*
(reference value)
Model
Quantity
Applicable Sensors
Remarks
3.5 m
E39-R1S
E3S-DB@@1(T)
Standard model
2m
E39-R1K
E3S-DB@@1(T)
Non-fogging reflective plate
3m
E39-RP1
E3S-DB@@1(T)
Special Polarizing Reflector
0.5 m (rated value)
E39-R21
E3S-DB@@2(T)
Narrow-beam Reflector
E3S-DB@@1(T)
Standard model
1
3.5 m (rated value)
E39-R8
1.5 m
E3S-DB@@1(T)
E39-RS10
0.5 m
E3S-DB@@2(T)
2.5 m
E3S-DB@@1(T)
Sheets
E39-RS11
0.5 m
E3S-DB@@2(T)
Note: 1. If you use the Reflector at any distance other than the rated distance, make sure that the stability indicator lights properly when you install
the Sensor.
2. Refer to Engineering Data (Reference Value) on page 4 for details.
* There is no close-range dead zone between the Sensor and Reflector.
Mounting Brackets (Refer to Dimensions on page 11.)
A Mounting Bracket is not provided with the Sensor. It must be ordered separately as required.
Type
Bottom-mounting
Appearance
Model
Quantity
E39-L192
1
Side-mounting
E39-L193
Note: For details, refer to the Mounting Brackets on E39-L/E39-S/E39-R which can be accessed from your OMRON website.
2
E3S-DB
Ratings and Specifications
Sensing method
Model
Item
Retro-reflective (with MSR function)
NPN output
E3S-DBN@1
E3S-DBN@1T
E3S-DBN@2
E3S-DBN@2T
PNP output
E3S-DBP@1
E3S-DBP@1T
E3S-DBP@2
E3S-DBP@2T
Sensing distance
0 to 3.5 m (with E39-R8)
0 to 0.5 m (with E39-R21)
Spot diameter (reference value)*1
6-mm dia. (at sensing distance of 250 mm)
2.5-mm dia. (at sensing distance of 200 mm)
Light source (wavelength)
Red LED (624 nm)
Power supply voltage
10 to 30 VDC, including 10% ripple (p-p)
Power consumption
720 mW max. (current consumption: 30 mA max. at power supply voltage of 24 VDC)
Control output
Load power supply voltage: 30 VDC max., Load current: 100 mA max. (Residual voltage: 2 V max.)
Open-collector output (NPN/PNP output depending on model.)
Indicators
Light indicator (orange) and stability indicator (green)
Protection circuits
Reversed power supply polarity protection, output short-circuit protection, reversed output polarity
protection, and mutual interference prevention
Response time
Operate or reset: 0.5 ms max.
Sensitivity adjustment
Smart Teaching
Eleven-turn adjuster
Smart Teaching
Eleven-turn adjuster
Smart Teaching lock function
Provided.
---
Provided.
---
Automatic compensation (AC3)
Provided (OFF by
default).
---
Provided (OFF by
default).
---
Ambient illumination
(Receiver side) Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max.
Ambient temperature range
Operating: −25 to 60°C, Storage: −40 to 70°C (with no icing or condensation)
Ambient humidity range
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)
Insulation resistance
20 MΩ min. (at 500 VDC)
Dielectric strength
1,000 VAC at 50/60 Hz for 1 minute
Vibration resistance
Destruction: 10 to 55 Hz with double amplitude of 1.5 mm for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2 3 times each in X, Y, and Z directions
Degree of protection*2
IEC IP67, DIN 40050-9 IP69K
Connection method
Pre-wired cable (standard cable length: 2 m)
Connector (M12, 4 pins)
Pre-wired connector (standard cable length: 0.3 m/M12, 4 pins)
Weight (packed
state/Sensor
only)
Materials
Pre-wired models
Approx. 80 g/approx. 60 g
Models with
connector
Approx. 60 g/approx. 40 g
Models with pre-wired
Approx. 180 g/approx. 160 g
connector
Case
Polybutylene terephthalate (PBT)/ABS
Lens
Methacrylic resin (PMMA)
Indicators
Methacrylic resin (PMMA)
Sensitivity adjuster
Polyester elastomer
and
Threshold adjuster
Cable
Accessories
Polyvinyl chloride (PVC)
Instruction manual
*1. Refer to Emission Spot Diameter vs. Distance in Engineering Data (Reference Value) on page 4 for details.
*2. IP69K Degree of Protection Specification
IP69K is a protection standard against high temperature and high-pressure water defined in the German
standard DIN 40050, Part 9. The test piece is sprayed with water at 80°C at a water pressure of 80 to 100
BAR using a specified nozzle shape at a rate of 14 to 16 liters/min.
The distance between the test piece and nozzle is 10 to 15 cm, and water is sprayed horizontally for 30
seconds each at 0°, 30°, 60°, and 90° while rotating the test piece on a horizontal plane.
3
E3S-DB
Engineering Data (Reference Value)
Parallel Operating Range
60
40
E3S-DB@@2(T) + E39-R21 (Reflector)
100
80
Y
60
X
40
20
0
−20
−20
−10
−60
−15
−80
−60
0
0.5
1.0
1.5
2.0
2.5
−100
0
3.0
3.5
4.0
Distance x (m)
1.0
2.0
3.0
4.0
5.0
6.0
Distance x (m)
Excess Gain vs. Distance
E3S-DB@@2(T) + E39-R21 (Reflector)
100.0
Excess gain ratio (multiple)
Excess gain ratio (multiple)
E3S-DB@@1(T) + Reflector
E39-R8
10.0
100.0
10.0
E39-R21
E39-R1S
E39-R21
Operating 1.0
level
Operating 1.0
level
E39-RP1
0.1
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
0.1
0
4.0 4.5 5.0
Distance (m)
0.5
1.0
1.5
2.0
2.5
3.0
Distance (m)
E3S-DB@@1(T)
E3S-DB@@2(T)
Emission spot diameter (mm)
Emission spot diameter (mm)
Emission Spot Diameter vs.
Distance
250
200
150
25
20
15
100
10
50
5
0
0
0.5
1
1.5
2
2.5
3
3.5
4 4.5 5
Distance (m)
0
0
0.1
Note: These values were measured at maximum sensitivity.
4
X
10
−5
−40
−40
Y
15
0
0
X
20
5
20
Y
Distance Y (mm)
E3S-DB@@1(T) + E39-R8 (Reflector)
Distance Y (mm)
Distance Y (mm)
E3S-DB@@1(T) + E39-R1S (Reflector)
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Distance (m)
−20
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
Distance x (m)
E3S-DB
Attenuation Level vs. Sensing Object Characteristics (Typical Values)
70
1.75 m
3.5 m
80
70
100
90
70
60
10
0
0
0
Glass bottles
PET bottles
Glass bottles
Transparent tray
20
10
Transparent film
(from cigarette pack)
20
10
Filled with
water
20
Empty
30
Filled with
water
40
30
Empty
40
30
Transparent tray
40
Transparent film
(from cigarette pack)
50
Filled with
water
50
50
Empty
60
Filled with
water
60
PET bottles
1.25 m
2.5 m
80
PET bottles
Transparent film
(from cigarette pack)
2m
90
Filled with
water
1m
80
E3S-DB@@1(T) + E39-RP1 (Special Polarizing Reflector)
Empty
90
100
Attenuation level (%)
Attenuation level (%)
100
Empty
Attenuation level (%)
E3S-DB@@1(T) + E39-R1S/E39-R1K (Reflector) E3S-DB@@1(T) + E39-R8 (Reflector)
100
90
250 mm
500 mm
80
70
60
50
40
30
20
10
Transparent tray
Filled with
water
Glass bottles
Transparent film
(from cigarette pack)
PET bottles
Empty
Filled with
water
0
Empty
Attenuation level (%)
E3S-DB@@2(T) + E39-R21 (Reflector)
5
E3S-DB
I/O Circuit Diagrams
NPN Output
Operation
mode
Model
Light ON
Timing charts
Incident light
No incident light
ON
Light indicator
OFF
(orange)
ON
Output 1
OFF
Operate
Load (e.g., relay)
Reset
Output circuit
Brown
Light
indicator
(orange)
Dark ON
Load 1
Black
Output 1
Light ON
4
Photoelectric
Sensor main
circuit
Between brown (1) and black
(4) leads)
E3S-DBN@
E3S-DBN@T
10 to 30 VDC
1
Stability
indicator
(green)
Load 2
White
Output 2
2
Dark ON
Incident light
No incident light
ON
Light indicator
OFF
(orange)
ON
Output 2
OFF
Operate
Load (e.g., relay)
Reset
3
Blue
0V
1
2
4
M12, 4-pin Connector Pin
Arrangement
3
Between brown (1) and white
(2) leads)
PNP Output
Operation
mode
Model
Light ON
Timing charts
Incident light
No incident light
ON
Light indicator
OFF
(orange)
ON
Output 1
OFF
Operate
Load (e.g., relay)
Reset
Output circuit
Brown
Light
indicator
(orange)
Dark ON
Black
Output 1
Light ON
White
Output 2
2
Dark ON
4
Photoelectric
Sensor main
circuit
Between blue (3) and black (4)
leads)
E3S-DBP@
E3S-DBP@T
10 to 30 VDC
1
Stability
indicator
(green)
Incident light
No incident light
ON
Light indicator
OFF
(orange)
ON
Output 2
OFF
Operate
Load (e.g., relay)
Reset
3
Load 1
Load 2
Blue
0V
1
2
4
M12, 4-pin Connector Pin
Arrangement
3
Between white (2) and blue (3)
leads)
Connectors (Sensor I/O Connectors)
M12, 4-pin Connectors
Classification
Pin No.
2
1
3
4
1
2
3
4
Wire color
Brown
White
Blue
Black
DC
Wire color
Pin No.
Brown
A
Power supply (+V)
Application
White
B
Output 2 (Dark ON)
Blue
C
Power supply (0 V)
Black
D
Output 1 (Light ON)
Nomenclature
Smart Teaching Type
Stability indicator
(green)
Eleven-turn Adjuster Type
Light indicator
(orange)
Stability indicator
(green)
Light indicator
(orange)
Threshold adjuster
Teaching button
6
Sensitivity adjuster
E3S-DB
Safety Precautions
Be sure to read the precautions for all models in the website at: http://www.ia.omron.com/.
WARNING
Do not use the product with voltage in excess of the
rated voltage.
Excess voltage may result in malfunction or fire.
Never use the product with an AC power supply.
Otherwise, explosion may result.
The maximum power supply voltage is 30 VDC.
Before turning the power ON, make sure that the power
supply voltage does not exceed the maximum voltage.
Do not use the product under a chemical or an oil
environment without prior evaluation.
Precautions for Correct Use
1. If the Sensor wiring is placed in the same conduits or ducts as
high-voltage or high-power lines, inductive noise may cause
malfunction or damage. Wire the cables separately or use a
shielded cable.
2. If a commercial switching regulator is used, ground the FG (frame
ground) terminal.
3. The Sensor will be able to detect objects 100 ms after the power
supply is tuned ON. Start using the Sensor 100 ms or more after
turning ON the power supply. If the load and the Sensor are
connected to separate power supplies, be sure to turn ON the
Sensor first.
4. Output pulses may occur when the power supply is turned OFF.
We recommend that you turn OFF the power supply to the load
or load line first.
5. Use M4 screws to mount the sensor and tighten each screw to a
maximum torque of 1.2 N·m.
Precautions for Safe Use
Be sure to follow the safety precautions below for added safety.
1. Do not use the product in an environment where explosive or
flammable gas is present.
2. The degree of protection is IP69K, but do not use the product in
water, rain, or outdoors.
3. Do not use the product in atmospheres or environments that
exceed product ratings.
4. Do not use the product in locations subject to direct sunlight.
5. Do not use the product in locations subject to direct vibration or
shock.
6. Do not use thinner, alcohol, or other organic solvents. Otherwise,
the optical properties and degree of protection may be degraded.
7. Do not attempt to disassemble, repair, or modify the product in
any way.
8. When disposing of the product, treat it as industrial waste.
9. Do not use highly concentrated cleaning agents. Otherwise,
malfunction may result. Also, do not use high-pressure water with
a level of pressure that exceeds the stipulated level. Otherwise,
the degree of protection may be reduced.
10. Perform sensitivity adjustment with the torque of 0.06 N·m or less.
11. Do not pull on the cable with excessive strength.
12. Do not exert excessive force on the connector section.
13. This product cannot be used as a detection system to protect
human bodies.
14. These Sensors are certificated for the UL standard on the
assumption of usage in a Class 2 circuit. Use them with Class 2
power supplies in the United States or Canada. Use the OMRON
XS2F-D4-series or XS5F-D4-series Cables. Cables that have
wires less than AWG24 (0.2 mm2) are for connection to terminal
blocks and are not for field splicing. External overcurrent
protection of 1 A for AWG26, 2 A for AWG24, or 3 A for AWG22
wire must be provided for cable protection.
7
E3S-DB
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Sensors
Pre-wired Models
E3S-DBN1@(T)
E3S-DBP1@(T)
Models with Pre-wired Connector
E3S-DBN3@(T)
E3S-DBP3@(T)
Smart Teaching Type
Light indicator (orange)
Stability indicator (green)
Threshold adjuster
Teaching button
12.4
3.4
Mounting Holes
24.2
4.2
69.2
40.5
36
29.9
3.2
4.2
15.8
40±0.1
(53°)
19.4
12.9
1
29.9±0.1
Two, M4
17
Two,
R: 2.1
(41)
40
5.4
Lens
(9.4 dia.)
Connector on Models with
Pre-wired Connector
20
48.5
44.7
(77.2)
14.9 dia.
Two, R: 2.1
M12×1
Three,
4.2 dia.
6 dia. vinyl-insulated round cable with 4 conductors
(Conductor cross-sectional area: 0.5 mm2 (AWG20),
Conductor outer diameter: 0.8 mm/Insulator diameter: 1.7 mm)
Standard length: 2 m
Minimum bending radius: 18 mm
(33)
Eleven-turn Adjuster Type
6 dia. vinyl-insulated round cable with 4
conductors (Conductor cross-sectional
area: 0.5 mm2 (AWG20),
Conductor outer diameter: 0.8
mm/Insulator diameter: 1.7 mm)
Standard length: 0.3 m
Minimum bending radius: 18 mm
Connector Pin
Arrangement
1
2
4
3
Light indicator (orange)
Stability indicator (green)
Sensitivity adjuster
12.4
3.4
23.9
4.2
69.2
40.5
36
29.9
3.2
4.2
15.8
19.4
12.9
17
Two,
R: 2.1
1
20
(41)
40
5.4
Lens
(9.4 dia.)
48.5
(77.2)
Two, R: 2.1
Three,
4.2 dia.
(33)
8
6 dia. vinyl-insulated round cable with 4 conductors
(Conductor cross-sectional area: 0.5 mm2 (AWG20),
Conductor outer diameter: 0.8 mm/Insulator diameter: 1.7 mm)
Standard length: 2 m
Minimum bending radius: 18 mm
Pin No.
Application
A
Power supply (+V)
B
Output 2 (Dark ON)
C
Power supply (0 V)
D
Output 1 (Light ON)
E3S-DB
Models with M12 Connector
E3S-DBN2@(T)
E3S-DBP2@(T)
Smart Teaching Type
Light indicator (orange)
Stability indicator (green)
Threshold adjuster
Teaching button
12.4
3.4
24.2
4.2
Mounting Holes
55.5
40.5
36
29.9
3.2
4.2
15.8
19.4
12.9
40±0.1
1
(53°)
17
Two,
R: 2.1
41
40
5.4
Lens
(9.4 dia.)
29.9±0.1
Two, M4
20
48.5
(63.5)
Connector Pin
Arrangement
1
2
Two, R: 2.1
Three,
4.2 dia.
(33)
Connector
M12
Eleven-turn Adjuster Type
Light indicator (orange)
4
3
Pin No.
Application
A
Power supply (+V)
B
Output 2 (Dark ON)
C
Power supply (0 V)
D
Output 1 (Light ON)
Stability indicator (green)
Sensitivity adjuster
12.4
3.4
23.9
4.2
55.5
40.5
3.2
4.2
15.8
36
29.9
19.4
12.9
17
Two,
R: 2.1
1
20
41
40
5.4
Lens
(9.4 dia.)
48.5
(63.5)
Two, R: 2.1
Three,
4.2 dia.
(33)
Connector
M12
9
E3S-DB
Accessories (Sold Separately)
Reflector
E39-R1S/E39-R1K*
40.3
34
Two, 3.5 dia.
7.5
7
59.9 52
8
Materials: Reflective surface: Acrylic, Rear surface: ABS
* E39-R1K only
Coating on reflective surface
2.7
1.6
Special Polarizing Reflector
E39-RP1
8.5
3
0.2
44
80
72 63.6
Reflective surface
Materials: Reflective surface: Acrylic, Rear surface: ABS
Two, 3.5 dia.
Reflector
E39-R21
30
25
2.5
3
5
35
Materials: Reflective surface: Methacrylic resin (PMMA),
Rear surface: Polybutylene terephthalate (PBT)
Reflector
E39-R8
9
Two, 3.2 dia.
5
29
25
3
24
100
00
92
92
100
00
Two, 3.2 dia.
Materials: Reflective surface: Acrylic, Rear surface: ABS
Reflector
E39-RS10
E39-RS11
0.32
(without release paper)
0.32
(without release paper)
50
25
25
50
Materials: Reflective surface: Methacrylic resin (PMMA)
10
Materials: Reflective surface: Methacrylic resin (PMMA)
E3S-DB
Mounting Brackets
E39-L192
With Sensor Mounted
Material: SUS304
42.9
R1
26.2
Two, 4.5-dia. holes
29.9
(3)
5
R49.9
±0.1
20
4.5
4.5 d
25.4
ia.
40±0.1
R3.5
5
61.8
R2
4.5
58.8
R2.25
54.5
90°±0.5°
23.8
33.3
8.8
R3 max.
5°
31.8
R5
30°
R2.25
10.1
(3)
47.6
54.5
15
42.9
29.9
A*
R2.25
4.5 dia.
R
18.3
49
.9
40
30° 28.8
61.8
44
90°
5°
Two, R5
R2.25
t=3
R25±0.1
54.5
47.6
* The Mounting Bracket can be attached to side A.
E39-L193
With Sensor Mounted
Material: SUS304
7
7
3.9
6.5
6.5
Six, R2.25
Six, R2.25
11.4
20±0.1
11.4
90°
20±0.1
4.5 dia.
35
4.5 dia.
R20±0.1
20°
3.9
R20±0.1
20°
10
10
40.8
51
(3)
20°
25
20°
R20
R1
90°±0.5°
R20
25
20
(3)
7.1
20
7
48.5
7
15
B*
22.9
* The Mounting Bracket can be attached to side B.
11
MEMO
12
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
OMRON Corporation
Industrial Automation Company
Authorized Distributor:
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
© OMRON Corporation 2015 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
CSM_2_2_0815
Cat. No. E439-E1-01
0515 (0515)