All Metals and Long-distance Types E2V CSM_E2V_DS_E_3_2 Aluminum and Iron Both Detectable from Long Distances 2 times the aluminum detection distance of previous models Twice the max. distance Equipped with a function to prevent the detection of aluminum chips Aluminum chip protection Long-distance aluminum detection For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to Safety Precautions on page 8. Features Aluminum Detection Distance: 2 Times Previous Models * Immunity against aluminum chips has enabled achieving long-distance detection of aluminum workpieces. The same detection distance has also been achieved for iron, allowing the E2V-X@ to be separated from workpieces made of either metal farther than any other Proximity Sensor. Aluminum Excellent Performance, with Aluminum Chip Immunity! Iron Also Detects Iron at Long Distances! E2V E2V E2EZ E2EZ Aluminum Chip Immunity E2EM E2EM Long-distance (Ferrous Metals) E2E E2E Standard Model 0 0 1 2 3 4 5 6 7 8 1 9 2 3 4 5 6 7 8 9 Sensing distance (mm) Sensing distance (mm) * In-house comparison of M18 Shielded Long-distance Models Detection Made Visible An operation indicator that is visible from any direction is provided as a standard feature. This indicator flashes under unstable conditions for easy installation condition verification at a glance. The indicator may be difficult to see from some directions. Visible The indicator is visible from any direction. The indicator is visible from any direction. 180° 180° 180° Previous Sensor E2V Pre-wired Models and Pre-wired Connector Models E2V Connector Models Embeddable in Metal. The first Long-distance Sensor that is shielded. Possible to be completely embedded in metal. Workpiece Bracket Protruding distance Workpiece Embedded Mounting in Metal E2EM E2V 1 E2V Ordering Information Sensors (Dimensions ➜ page 9) Standard-distance type DC 3-wire, Pre-wired Models (Standard Cable Length: 2 m) Appearance Sensing distance M12 Output PNP 2 mm NPN Shielded M18 PNP 5 mm NPN PNP M30 10 mm NPN Model Operation mode NO Operation mode NC E2V-X2B1 2M E2V-X2C1 2M E2V-X5B1 2M E2V-X5C1 2M E2V-X10B1 2M E2V-X10C1 2M E2V-X2B2 2M E2V-X2C2 2M E2V-X5B2 2M E2V-X5C2 2M E2V-X10B2 2M E2V-X10C2 2M Long-distance type DC 3-wire, Pre-wired Models (Standard Cable Length: 2 m) Appearance Sensing distance M12 Output PNP 4 mm NPN Shielded PNP M18 8 mm NPN PNP M30 15 mm NPN Model Operation mode NO Operation mode NC E2V-X4B1 2M E2V-X4C1 2M E2V-X8B1 2M E2V-X8C1 2M E2V-X15B1 2M E2V-X15C1 2M E2V-X4B2 2M E2V-X4C2 2M E2V-X8B2 2M E2V-X8C2 2M E2V-X15B2 2M E2V-X15C2 2M Long-distance type DC 3-wire, Connector Models Appearance Sensing distance M12 Output PNP 4 mm NPN Shielded M18 PNP 8 mm M30 NPN 15 mm PNP NPN Model Operation mode NO Operation mode NC E2V-X4B1-M1 E2V-X4C1-M1 E2V-X8B1-M1 E2V-X8C1-M1 E2V-X15B1-M1 E2V-X15C1-M1 E2V-X4B2-M1 E2V-X4C2-M1 E2V-X8B2-M1 E2V-X8C2-M1 E2V-X15B2-M1 E2V-X15C2-M1 Long-distance type DC 3-wire, Smartclick Pre-wired Connector (M12) Models Appearance Sensing distance M12 PNP 4 mm NPN Shielded M18 M30 Output PNP 8 mm NPN PNP 15 mm NPN Model Operation mode NO E2V-X4B1-M1TJ 0.3M E2V-X4C1-M1TJ 0.3M E2V-X8B1-M1TJ 0.3M E2V-X8C1-M1TJ 0.3M E2V-X15B1-M1TJ 0.3M E2V-X15C1-M1TJ 0.3M 2 E2V Accessories (Order Separately) Sensor I/O Connectors (M12, Sockets on One Cable End) (Required for models with Pre-wired Connectors.) A Connector is not provided with the Sensor. Be sure to order a Connector separately. (Dimensions ➜ XS5) Appearance Smartclick Connector, Straight Type Cable length Model 2m XS5F-D421-D80-F 5m XS5F-D421-G80-F 2m XS5F-D421-D80-P 5m XS5F-D421-G80-P Applicable Proximity Sensor Models Standard cable Oil-resistant polyurethane cable E2V-X@B1-M1TJ E2V-X@C1-M1TJ Sensor I/O Connectors (M12, Sockets on One Cable End) Standard type (Required for models for Connectors.) A Connector is not provided with the Sensor. Be sure to order a Connector separately. (Dimensions ➜ XS2) Appearance Straight L-shape Cable length Sensor I/O Connector model number 2m XS2F-D421-DC0-F 5m XS2F-D421-GC0-F 2m XS2F-D421-D80-F 5m XS2F-D421-G80-F 2m XS2F-D422-DC0-F 5m XS2F-D422-GC0-F 2m XS2F-D422-D80-F 5m XS2F-D422-G80-F Applicable Proximity Sensor Models E2V-X@C1-M1 E2V-X@B1-M1 E2V-X@C@-M1 E2V-X@B@-M1 E2V-X@C1-M1 E2V-X@B1-M1 E2V-X@C@-M1 E2V-X@B@-M1 3 E2V Ratings and Specifications Size M12 Item Model E2V-X2@@ M18 M30 E2V-X4@@ E2V-X5@@ E2V-X8@@ E2V-X10@@ E2V-X15@@ 2 mm±10% 4 mm±10% 5 mm±10% 8 mm±10% 10 mm±10% 15 mm±10% Set distance 0 to 1.6 mm 0 to 3.2 mm 0 to 4.0 mm 0 to 6.4 mm 0 to 8.0 mm 0 to 12.0 mm Differential travel 10% max. of sensing distance Detectable object Ferrous metals and non-ferrous metals (The sensing distance depends on the material of the sensing object. Refer to Engineering Data (Reference value).) Standard sensing object Aluminum: 12 × 12 × 3 mm Aluminum: 12 × 12 × 3 mm Aluminum: 18 × 18 × 3 mm Aluminum: 24 × 24 × 3 mm Aluminum: 30 × 30 × 3 mm Aluminum: 45 × 45 × 3 mm Response frequency * 150 Hz 40 Hz 70 Hz 40 Hz 70 Hz 30 Hz Power supply voltage (operating voltage range) 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. Current consumption 450 mW max. (Current consumption: 15 mA max. at power supply voltage of 30 V) Control output Sensing distance Load current Open-collector output, 100 mA max. Residual voltage 2 V max. (Load current: 100 mA, Cable length: 2 m) NO Models: Operation indicator (yellow) (flashing), Setting indicator (yellow) (lit); NC Models: Operation indicator (yellow) (lit) Operation mode B1/C1 Models: NO (Refer to the timing charts under I/O Circuit Diagrams for details.) B2/C2 Models: NC Protection circuits Power supply reverse polarity protection, reversed output polarity protection, load short-circuit protection, surge suppressor Ambient temperature Operating/Storage: -25 to 70°C (with no icing or condensation) Ambient humidity Operating/Storage: 35% to 95% (with no condensation) Temperature influence Based on the sensing distance at 23°C in the temperature range of -25 to 70°C Voltage influence ±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions Degree of protection IEC IP67 (Pre-wired Models and Pre-wired Connector Models are oil-resistant to the OMRON in-house standard.) Connection method Pre-wired Models (Standard cable length: 2 m), Connector Models, Pre-wired Connector Models (Standard cable length: 300 mm) Materials Weight (packed state) Indicators ±10% max. ±15% max. ±10% max. ±15% max. ±10% max. Cable Approx. 120 g Approx. 150 g Approx. 200 g Connector Approx. 30 g Approx. 45 g Approx. 120 g Pre-wired Connector Models Approx. 50 g Approx. 70 g Approx. 140 g Case Nickel-plated brass Sensing surface Heat-resistant ABS Clamping nuts Nickel-plated brass Toothed washer Zinc-plated iron Accessories ±15% max. Instruction manual * The response frequency is an average value. Measurement conditions are as follows: Standard sensing object, a distance between target objects of twice the size of the standard sensing object, and a set distance of half the sensing distance. 4 E2V Engineering Data (Reference Value) Influence of Sensing Object Size and Material E2V-X2 E2V-X4 E2V-X5 5.0 3.0 Iron 6.0 Sensing distance X (mm) 4.0 Brass 2.0 Aluminum Copper 1.5 Stainless steel (SUS304) 1.0 @ d t= 3 mm 0.5 Brass Sensing distance X (mm) 2.5 Sensing distance X (mm) 7.0 Iron 4.5 3.5 Aluminum 3.0 Copper 2.5 Stainless steel (SUS304) 2.0 1.5 0.0 0 5 10 15 20 25 Side length of sensing object d (mm) 30 E2V-X8 0 5 10 15 20 25 Side length of sensing object d (mm) 6.0 Iron 4.0 Stainless steel (SUS304) Copper 6.0 Stainless steel (SUS304) Iron 4.0 @ d t= 3 mm 2.0 X 5 10 15 20 25 30 35 Side length of sensing object d (mm) 40 Brass Aluminum 14.0 8.0 @ d t= 3 mm 2.0 0 16.0 Aluminum Sensing distance X (mm) Sensing distance X (mm) Sensing distance X (mm) Aluminum X 18.0 10.0 Copper Stainless steel (SUS304) 2.0 E2V-X15 Brass Brass Iron 3.0 0.0 30 12.0 8.0 Aluminum 1.0 E2V-X10 10.0 Copper 4.0 @ d t= 3 mm X 0.5 0.0 5.0 t= 3 mm @d 1.0 X Brass Copper 12.0 Iron 10.0 8.0 Stainless steel (SUS304) 6.0 4.0 @ d t= 3 mm X X 2.0 0.0 0 5 10 15 20 25 30 35 Side length of sensing object d (mm) 0.0 40 0 10 20 30 40 50 Side length of sensing object d (mm) 0.0 60 0 10 20 30 40 50 Side length of sensing object d (mm) 60 Influence of Sensing Object Size and Material E2V-X2 E2V-X4 3.0 E2V-X5 5.0 7.0 4.5 Brass Iron Aluminum Copper 1.5 1.0 Stainless steel (SUS304) 0.5 t 0 1 2 3 4 5 Thickness of sensing object: t (mm) Aluminum 3.0 Copper 2.5 2.0 Stainless steel (SUS304) 1.5 1.0 t X 0.5 Sensing object size: 12 × 12 mm 0.0 3.5 6 Sensing distance X (mm) Brass 2.0 6.0 Iron 4.0 Sensing distance X (mm) Sensing distance X (mm) 2.5 0.0 X Aluminum 5.0 Iron 4.0 Copper 3.0 Stainless steel (SUS304) 2.0 t 1.0 1 2 3 4 5 Thickness of sensing object: t (mm) X Sensing object size: 18 × 18 mm Sensing object size: 12 × 12 mm 0 Brass 6 0.0 0 1 2 3 4 5 6 7 Thickness of sensing object: t (mm) 8 5 E2V E2V-X8 E2V-X10 10.0 18.0 12.0 16.0 Aluminum Brass Brass 10.0 8.0 6.0 Stainless steel (SUS304) 4.0 2.0 t Iron 8.0 Copper 6.0 Stainless steel (SUS304) 4.0 Sensing object size: 24 × 24 mm 0.0 0 1 2 3 4 5 6 7 Thickness of sensing object: t (mm) Iron 12.0 Copper 10.0 Stainless steel (SUS304) 8.0 6.0 t X Sensing object size: 30 × 30 mm 0.0 8 Brass 4.0 t 2.0 X Sensing distance X (mm) Copper Iron Aluminum 14.0 Aluminum Sensing distance X (mm) Sensing distance X (mm) E2V-X15 Sensing object size: 45 × 45 mm 0.0 0 2 4 6 8 10 Thickness of sensing object: t (mm) X 2.0 12 0 2 4 6 8 10 Thickness of sensing object: t (mm) 12 Sensing Area 16.0 14.0 16.0 Y X 14.0 Y X E2V-X15@ E2V-X15@ 12.0 E2V-X10@ 10.0 E2V-X8@ 8.0 6.0 E2V-X5@ 4.0 E2V-X4@ 2.0 E2V-X2@ Sensing distance X (mm) Sensing distance X (mm) 12.0 10.0 E2V-X10@ 8.0 E2V-X8@ 6.0 E2V-X5@ 4.0 E2V-X4@ 2.0 E2V-X2@ 0.0 -12.0 -9.0 -6.0 -3.0 0.0 3.0 6.0 9.0 12.0 Sensing distance Y (mm) Sensing area (Aluminum) (Thickness: 3.0 mm) 0.0 -12.0 -9.0 -6.0 -3.0 0.0 3.0 6.0 9.0 12.0 Sensing distance Y (mm) Sensing area (Iron) (Thickness: 3.0 mm) 6 E2V I/O Circuit Diagrams NPN Output Model Operation mode Timing charts Output circuit Set position Non-sensing Unstable Stable sensing area sensing area area Proximity sensor Brown Sensing object NO +V 100 80 (%) Load 0 Rated sensing distance Flashing Proximity Sensor main circuit ON Yellow indicator OFF ON Control output OFF E2V-X@C@ (-M1/-M1TJ) Black Blue 0V Non-sensing area Sensing area Note: Connector Models NO Models: NC Models: Proximity sensor Sensing object 100 (%) NC 0 M1: M1TJ: Rated sensing distance ON Yellow indicator OFF ON Control output OFF Compatible Connector Cables: XS5F Series XS2F Series PNP Output Model Operation mode Timing charts Output circuit Set position Non-sensing Unstable Stable sensing area sensing area area Proximity sensor Brown Sensing object NO (%) +V 100 80 Rated sensing distance Flashing 0 Proximity Sensor main circuit ON Yellow indicator OFF ON Control output OFF E2V-X@B@ (-M1/-M1TJ) Black Load Blue 0V Sensing area Proximity sensor Non-sensing area Note: Connector Models NO Models: NC Models: Sensing object (%) NC 100 0 M1: M1TJ: Rated sensing distance ON Yellow indicator OFF ON Control output OFF Compatible Connector Cables: XS5F Series XS2F Series Connections for Sensor I/O Connectors Sensor I/O Connector model number XS2F-D42@-@C0-F NO E2V-X@C1-M1 E2V-X@B1-M1 D: 2-m cable G: 5-m cable E2V Main Circuit 1: Straight 2: L-shape Connections XS2F 1 1 2 2 3 3 4 4 E2V DC 3-wire 1: Straight 2: L-shape Main Circuit Model Brown (+V) Blue (0 V) Black (Output) XS2F 1 1 2 2 3 3 4 4 Brown (+V) White (Blank) Blue (0 V) Black (Output) XS2F-D42@-@80-F NC E2V-X@C2-M1 E2V-X@B2-M1 D: 2-m cable G: 5-m cable E2V Main Circuit Type Proximity Sensor Operation mode XS2F 1 1 2 2 3 3 4 4 Brown (+V) White (Output) Blue (0 V) Black (Blank) Refer to Introduction to Sensor I/O Connectors/Sensor Controllers for details. 7 E2V Safety Precautions Refer to the Proximity Sensors Technical Guide. WARNING Sensing Distance This product is not designed or rated for ensuring safety of persons. Do not use it for such purposes. • The sensing distance depends on the sensing object size, material, and thickness. • If the sensing object has a thickness of less than 1 mm, the sensing distance will decrease. • In some cases, it may not be possible to detect stainless steel. Use the following graph and the Influence of Sensing Object Size and Material information in Engineering Data (Reference Value) as a reference. Never use the product with an AC power supply. Otherwise, explosion may result. Precautions for Correct Use Do not use the product in atmospheres or environments that exceed product ratings. Designing Influence of Surrounding Metal When embedding the Sensor in metal, be sure that the clearances given in the following table are maintained. D m t t t Table 1. Influence of Surrounding Metal Item Model ℓ d dia. D m n Normally aluminum or iron cuttings will not be detected even if they adhere to or accumulate on the sensing surface. Detection signals may be output for the following. If this occurs, remove the cuttings from the sensing surface. Diameter of cutting = d and diameter of sensing surface = D Cuttings in center of sensing surface with d ≥ 2/3D (Unit: mm) Mode Size D E2V-X2@/X4@ 10 E2V-X5@/X8@ 16 E2V-X10@/X15@ 28 n m d dia. Aluminum and Iron Cuttings E2V-X2 0 12 0 12 18 E2V-X5 0 18 0 24 27 (Unit: mm) E2V-X10 0 30 0 45 45 E2V-X4 0 12 0 12 18 E2V-X8 0 18 0 24 27 E2V-X15 0* 30 * 0* 45 45 d Pressed against Cutting sensing surface. Cutting Sensing surface D Tightening Torque Do not tighten the nut with excessive force. A washer must be used with the nut. (Shielded Model) Part B Part A Item Model ℓ d dia. D m n Tightening Torque Model E2V-X2/X4 E2V-X5/X8 E2V-X10/X15 Part A Dimension (mm) 17 22 26 Torque 5.9 N⋅m 15 N⋅m 39 N⋅m Part B Torque 9.8 N⋅m 45 N⋅m 78 N⋅m * If the thickness of the mounting bracket (t) exceeds 5 mm, be sure to install the Sensor so that ℓ ≥ 2, d (dia.) ≥ 45, and D ≥ 2. Mutual Interference When installing Sensors face-to-face or side-by-side, be sure that the minimum distances given in table 2 are maintained. B A Chart 2. Mutual Interference Item Model E2V-X2 30 20 E2V-X5 50 30 (Unit: mm) E2V-X10 100 50 Model E2V-X4 35 25 E2V-X8 60 35 E2V-X15 120 70 A B Item A B 8 E2V (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Sensors Pre-wired Models E2V-X5/X8 E2V-X2/X4 21 dia. 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m 60 17 47 M12 × 1 60 52 29 dia. 42 24 Indicator *1 Two clamping nuts Toothed washer 4 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m Indicator *1 M18 × 1 4 Two clamping nuts Toothed washer E2V-X10/X15 60 52 42 dia. 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m 42 36 Indicator *1 M30 × 1.5 5 Two clamping nuts Toothed washer *1 NO Models: Operation indicator (yellow) (flashing) Setting indicator (yellow) (ON) NC Models: Operation indicator (yellow) (ON) Pre-wired Connector Models E2V-X4-M1TJ E2V-X8-M1TJ 21 dia. 17 47 M12 × 1 4 60 29 dia. 60 6-dia. vinyl-insulated round cable Standard length: 300 mm Indicator *1 Two clamping nuts Toothed washer 52 42 24 M12 × 1 6-dia. vinyl-insulated round cable Standard length: 300 mm Indicator *1 M18 × 1 4 M12 × 1 Two clamping nuts Toothed washer E2V-X15-M1TJ 60 52 42 42 dia. 36 6-dia. vinyl-insulated round cable Standard length: 300 mm Indicator *1 M30 × 1.5 5 M12 × 1 Two clamping nuts Toothed washer *1 NO Models: Operation indicator (yellow) (flashing) Setting indicator (yellow) (ON) NC Models: Operation indicator (yellow) (ON) 9 E2V Connector Models B Model D C E F A G Item M12 × 1 Four indicators *1 Two clamping nuts Toothed washer *1 NO Models: Operation indicator (yellow) (flashing) Setting indicator (yellow) (ON) NC Models: Operation indicator (yellow) (ON) A B C D E F G E2V-X4@-M1 E2V-X8@-M1 E2V-X15@-M1 M12 × 1 65 47 52 21 dia. 17 4 M18 × 1 60 42 47 29 dia. 24 4 M30 × 1.5 63 42 49 42 dia. 36 5 Mounting Hole Dimensions Proximity Sensor dimensions Dimension H (mm) M12 12.5 +0.5 0 M18 dia. 18.5 +0.5 0 M30 dia. 30.5 +0.5 0 dia. H 10 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2015.4 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2015 All Right Reserved.