www.osram.com SubstiTUBE® Value EM – ST8V-1.2m-17W-EM Datasheet Innovative LED-lamp, easy and safe to use in CCG installations as direct retrofit. Energy saving potential of up to 61% by replacing 1.2 m T8 fluorescent tubes. Instant 100% light without flickering. No mercury. Applicable in warehouses, cold storage, supply rooms, corridors, industry, stairways, garages, etc; for applications with high operating hours. Technical operating data Color Colortemp. [K] Lum. Flux [lm] ST8V-1.2m-17W865-EM Cool Daylight 6500 K 1700 ST8V-1.2m-17W840-EM Cool White 4000 K 1700 ST8V-1.2m-17W830-EM Warm White 3000 K 1530 Product Voltage [V] / Frequency [Hz] Input current [mA] 220 - 240 V 50 / 60 Hz 77 mA Power [W] 17 W RadianceAngle [°] 220° All Data are related to the entire lamp. Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical data. Technical Features LED lamp in T8 shape with G13 socket Up to 30.000 h lifetime Glass body Switching cycles > 200.000 Weight: 214 g Color Rendering Index (CRI) > 80 For operation at magnetic ballast without High color homogeneity rewiring Direct Retrofit for CCG luminaires; replacement of lamp and included starter RoHS-conformity, no mercury Not for operation with ECG, not dimmable Energy Efficiency Class: A+ Powerfactor > 0.9 ST8V-1.2m – April 2016 Page 1 of 5 Minimum / Maximum ratings Operating temperature Tc ST8V-1.2m Storage temperature Ambient temperature Ts Ta -20° … 65°C -20° … 80°C -20° ... 45°C Drawings Product ST8V-1.2m ST8V-1.2m – April 2016 l d 1200 mm 27.5 mm Page 2 of 5 Safety and Application notes ® The SubstiTUBE When operating with CCG, the included “SubstiTUBE Start” has to be inserted as well. If the ® conventional starter is not replaced the SubstiTUBE Value will start blinking. Switch off ® immediately, the SubstiTUBE Value can be damaged! Value must not be damaged or operated in a damaged condition. ® Lamp suitable for 50 Hz or 60 Hz operation Lamp not suitable for high frequency operation Lamp not suitable for emergency operation ® Do not use SubstiTUBE Value in luminaires which do not have any starter or when the starter cannot be replaced. Not usable in luminaires with serial lamp connection i.e. more than one tube at one magnetic ballast (tandem circuitry). The SubstiTUBE® Value emits light only with a limited angle, not like a fluorescent tube with 360°output. Due to the characteristic light distribution of the SubstiTUBE® Value, the resulting luminaire light characteristic is likely to change. It is not guaranteed that e.g. standards for lighting at working places will be complied to after replacement. A photometric check of the installation is recommended. The effective energy savings depend on the efficiency of the luminaire setup to be replaced and should be considered individually in each case. Particularly magnetic ballast losses are reduced to ohmic losses and are normally only about 1 W. ® The SubstiTUBE Value is protected according to IP20. Applications with external risk of moisture and dust can be served with an adequately protected luminaire. SubstiTUBE® products differ in their diameters and geometries from fluorescent lamps. Their use in open batten luminaires with gaskets is possible if no excessive force is expended during the fixing. Obtaining the necessary IP protection in open batten luminaires with gaskets cannot be ensured. SubstiTUBE® Value may also be driven directly on line voltage. In order to grant a safe operation mode please refer to the installation instructions for further information. ST8V-1.2m – April 2016 Page 3 of 5 Maximum amount of SubstiTUBE® Value on one circuit breaker Circuit breaker 10 A (B type) Circuit breaker 16 A (B type) // // // // // // CCG CCG incl. comp. cap. Direct mains CCG CCG incl. comp. cap. Direct mains // 80 // 20 // 85 // 130 // 30 // 135 Photobiological Safety of lamps and lamp systems according to IEC 62471. Risk Group: Exempt Installation Instructions for CGG Make sure that the supply voltage is disconnected. Carefully remove the fluorescent tube and starter according to the lamp holder type. Insert SubstiTUBE® Value and SubstiTUBE ® Start properly. Below an example for typical lamp holder types is described Turn the conventional lamp 90° degrees and take it out of the socket. Remove the conventional starter by turning it. Insert and latch the SubstiTUBE ® Start into starter socket. Insert SubstiTUBE® Value into socket and locate into position by turning 90°. Check light emission direction. Circuit diagram of a retrofitted CCG luminaire ST8V-1.2m – April 2016 Page 4 of 5 Ordering guide Product name Light color EAN* ST8V-1.2m-17W-865-EM Cool Daylight / 6500 K 4052899955776 ST8V-1.2m-17W-840-EM Cool White / 4000 K 4052899955752 ST8V-1.2m-17W-830-EM Warm White / 3000 K 4052899955738 S-Unit** 25 x 1 * EAN: Ordering number per single module ** S-Unit: Lamps per shipping unit Sales and Technical Support Sales and technical support is given by the local OSRAM subsidiaries. On our worldwide homepage all OSRAM subsidiaries are listed with complete address and phone numbers. Further Information Downloads: Eulumdat /IES files, CE declaration www.osram.com/SubstiTUBE OSRAM GmbH Head Office: Marcel-Breuer-Strasse 6 80807 Munich, Germany Phone +49 89 6213-0 www.osram.com ST8V-1.2m – April 2016 Page 5 of 5